Home
Hotkeys OSD (On Screen Display) User Manual
Contents
1. 3 5 ACCESS LIST Only SUPERVISOR can configure the ACCESS LIST The first column is the port number following the server computer name list The last 8 columns are the access right of each user Use the Enter key or left button of mouse to active deactivate the access right of each port X means to disable access and O means to enable access 97 dl Hotkey amp OSD Manual 2 3 6 HOTKEY Some keyboard may not equip with all the special keys Make sure the key you select is available in you keyboard 2 3 7 TIME SETTINGS When the Auto Scan function 1s activated the KVM switch will auto scan the host ports one by one in the interval as setting Notice that the port without connecting to a computer server will be skipped over on the scan The interval range is 5 99 seconds and the default interval is 10 seconds Press Enter key to save the SCAN TIME setting 2 3 8 OSD MOUSE You can change the moving speed of mouse cursor in this item There are three levels to choose from The fastest moving speed is FAST the second is MIDDLE and the slowest is SLOW Using and Y key on keyboard to move highlight bar to the wished speed Press the Enter key to go into effect 10 11 Hotkey amp OSD Manual 11 11
2. You will hear a beep sound confirming entering Hotkey mode If you do not press any key during Hotkey mode over 2 seconds the Hotkey mode will be escaped and back to Normal state The default hotkey is Caps Lock but you can change hotkey as your application convenience If you prefer to use other hotkey please go to OSD menu and change the default hotkey to the other The table blow lists all supported hotkey commands The default hotkey starts from Caps Lock Caps Lock then the keys on the table list Brings up the OSD overlay screen Switches to the previous port Switches to following port 1 2 8 bank The first digit is the Switch bank number starting 01 02 32 port with 1 The KVM switch on the daisy chain line is on bank 1 the Master A standalone KVM switch is also on bank 1 The second third digits are port numbers starting with 01 Switches to the previous bank Switches to next bank Turns the beep sound on off For SUPERVISORS that will set the OSD back to the factory default value except the User Security settings For SUPERVISORS that activates the Auto Scan function For SUPERVISORS that turns the Security function on off Default 1s off Log out that s only valid when the security is on 3 11 Hotkey amp OSD Manual Example 1 To bring up the OSD overlay window press Caps Lock Caps Lock and the Space Bar Immediately the OSD overlay scree
3. port right here Main Menu there are eight menus to operate They are listed as below 4 11 Hotkey amp OSD Manual 2 1 Login Window Power on the local console monitor and power on the KVM Switch by plug in the power adapter If the Security function is enabled default is disabled the Login window will show up waiting for user name and password The Login window The default is SUPERVISOR and default user name is eight zeros 00000000 The default password is eight zeros 00000000 There are case insensitive while OSD display fixed in upper case After login or port switch by panel button OSD or Hotkey the Status screen will show up to display the information of current settings one digit BANK NUMBER two digit PORT NUMBER PORT NAME and current Hotkey settings Pressing any key or moving mouse will let the Status screen disappeared The selected bank no The selected port no The Status screen The selected Hotkey Auto LOGOUT function In Login window if no input for username and password over minute the screen will disappear Hit any key to bring up the Login window again At normal operation if no input from the console keyboard or mouse over 10 minutes the KVM switch will turn off the screen display and show up Login window asking for user name and password One more minute of keyboard mouse inactivity the monitor will be turned off notice the monitor LED turns fro
4. Hotkeys OSD On Screen Display User Manual V2 0 2007 5 4 Hotkey amp OSD Manual Contents Be FOGOM isiciesescscucseselcesceuseesccesesceocessseucwessldesceutenesvedeaceecauasecewaueldexcsesasessedeaceesasaseeacaussvexceuseess 3 Zs HOT iio 3 3 OSD On Screen Display hiasi ciara iesea a a leed ERE sisi 4 oul LOCA a KG AAA O O er Renter tree RTT tren Rien RN 5 32 Port Nae iore at a ess A AA AAA 6 3 3 NU E nO E E sz aoa 7 3 3 1 LANGUA GE risa Es 7 3 32 PORTE NAME EDI cid 8 3 3 3 PORT SEARCH nana aia aia 8 3 3 4 USES SECURITY naa S 8 3 355 ACCESS LIS Esad is 9 3 3 6 ODE decis 10 3 3 7 TINTB SETTINOS ca aa 10 3 3 8 OSITOS eater ico 10 2 11 Hotkey OSD Manual Introduction Once all cables are connected power up the KVM switch and the connected computers it 15 ready for use now You can control the KVM switch by three ways local control from the front panel using the OSD On Screen Display or using hot key commands through the Console keyboard It takes approximately 1 2 seconds for the video signal to refresh after switching computers Re synchronization of the mouse and keyboard signals also occurs This is normal operation and ensures that proper synchronization 1s established between the Console and the connected computers 1 Hotkey You can conveniently command KVM switch through a simple hot key sequence To send commands to KVM switch you must press the hotkey default Caps Lock twice within 2 seconds
5. m green color to orange color 5 11 Hotkey amp OSD Manual 2 2 Port Name The first page shows the current port name and the selected port and the operation hint The selected bank The selected port Operation Hint Auto Scan Interval Firmware Version To log out the OSD If Security is enabled it will FO show up the Login window waiting for username and password If Security is disabled 1t will show up the Status window Show ports 01 08 USER There are two types of user levels SUPERVISOR and USER The default is SUPERVISOR SUPERVISOR can setup and change the OSD settings at Main Menu USER can only do the port switch and port search 6 11 Hotkey amp OSD Manual SCAN TIME This is the time interval for auto scan function When auto scan function is activated the KVM switch will auto scan the host port one by one in the interval as setting Notice that the port without connecting to a computer server will be skipped over on the scan The numeric keypad is not supported while in OSD screen the arrow keys PgUp PgDn and Enter keys are supported 2 3 Main Menu There are eight menus to choose from o 1 L A N G U AGE 0 2 P O R T N A M E E B I T 0 3 POR T lt E AR OC o 4 U S E R A A O O O O o 5 AC E E L I I 0 6 H O T K EY o 7 T I M E O O IO O GS ee E oO 8 A MO wU 8 E 2 3 1 LANGUAGE The OSD supports eight languages E
6. n will appear The superimposed menu screen is generated by the KVM switch and does not affect your computers or software function in any way 4 4 Caps Caps y A AA Example 2 To switch to Bank 1 Portl press Caps Lock Caps Lock and 1 0 1 XA Mm e 7 o SZE 7 Caps Caps Lock Lock l 1 HA LN SEEN SEEN Actually there are two methods to bring up the OSD overlay window please enter next key in 2 seconds in the Hotkey seguence please enter next key in 2 seconds in the Hotkey seguence 1 Activate OSD by press Hotkey press Hotkey twice then press Space bar 2 Activate OSD by Mouse Press and hold the left button of the mouse and hit the Esc key to show the Status screen Press and hold the right button of the mouse and hit the Esc key to bring up the Main Menu 2 OSD On Screen Display OSD Menu provides a menu driven interface to control the KVM switch This OSD Menu has four types of display screens 1 Login Window When powering on this KVM switch 1t will prompt a login window and ask for user name and password This KVM system can setup one SUPERVISOR and eight USERs SUPERVISOR can access to all OSD functions USER can access to PORT NAME and PORT SEARCH only 2 Status screen after the log in the Status screen will show up to display the current port settings and Hotkey type 3 Port Name this menu displays port status and you can switch to other
7. nglish French German Italian Spanish Simplified Chinese Japanese and Russian The default language is ENGLISH Moving the cursor by keyboard Up Arrow key or the Down Arrow key Y or mouse to select the language you like 0 1 EN GL 7 11 Hotkey amp OSD Manual 2 3 2 PORT NAME EDIT E Da 0 1 The first line bar is Bank number following lines are port name list Use keyboard Up Arrow key 47 Down Arrow key Y or mouse to select the port After select the port you can either press the Enter Key or move the cursor to port name and double click left button of mouse to switch the port immediately Press PgUp key or PgDn key for selecting the previous or next Bank Press Enter key for editing port name Press Esc key to cancel the editing without any change or press Enter key to complete the editing 2 3 3 PORT SEARCH PORT A SL ll S S Search the computer by port name Enter will show the all the port names 2 3 4 USER SECURITY There are two types of user levels SUPERVISOR and USER There is one SUPERVISOR and up to eight USERs can be configured 8 11 Hotkey amp OSD Manual p m 7 m 7 E m S ae a a a ae a S a a a a a S e a oo Press the Enter key or right button of mouse for editing The left top S means SUPERVISOR and 1 2 3 8 mean USERs The maximum length of NAME and PASSWORD is eight characters A Z and 0 9 2