PRO1D V11.122 series MID User manual

image

Contents

1.
2. PRO1D V11 122 series MID DIN rail single phase two wire energy meter User manual Version 1 0 DMMetering g 2011 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 Safety instructions Foreword MID certificates Type number table Performance criteria Specifications Basic errors Description Dimensions Installation Operation Troubleshooting Technical support User manual 0014 1 1 Safety instructions A A Information for Your Own Safety This manual does not contain all of the safety measures for operation of this equipment module device because special operating conditions local code requirements or local regulations may necessitate further measures However it does contain information which must be adhered to for your own personal safety and to avoid damage to the equipment This information is highlighted by a warning triangle with an exclamation mark or a lightning bolt depending on the severity of the warning Warning Means that failure to observe the instruction can result in death serious injury or considerable material damage Caution Means hazard of electric shock and failure to take the necessary safety precautions will result in death serious injury or considerable material damage Qualified personnel Installation and operation of this equipment described in this manual may only be performed by qualified personnel Only people that have proper knowledge about the local standards rega
3. The warranty period is 3 years after production and only valid for construction faults DMMeteringg 2011 sox User manual 0014 1 3 MID certificates KEMAX CERTIFICATE EC Type examination certificate 6319 10 Manufacturer Inepro Metering BV Contact person D van der Vaart Address P O Box 92 Postal code Place 2450 AB Leimuiden Country The Netherlands Instrument Electronic single phase two wire energy meter Direct connected Mark Type PRO 1TE PRO1D Register Mechanical LCD Accuracy Class B Measurement range 230V 5 45 A 50 Hz 2000 imp kWh Temperature range gt 10 40 C Use Indoor Protection Class an Environmental class M1 E2 Registry method bidirectional method with always positive register the meter always counts the energy of the measuring point as received energy irrespective of the real energy direction The energy meter meets the requirements of Directive 2004 22 EC of the European parliament and the council of 31 March 2004 on measuring instruments Certification was based on compliance with the following harmonised standards EN 50470 1 2006 Electricity metering equipment a c part 1 General requirements tests and test conditions Metering equipment class indexes A B and C EN 50470 3 2006 Electricity metering equipment a c part 3 Particular requirements Static meters for active energy class indexes A B and C Valid until March 30 2020 The result
4. meter should be installed on a location where the meter can be read easily When the meter is installed in an area with frequent surges for example due to thunderstorms welding machines inverters etc the meter should be protected with a Surge Protection Device After finishing installation the meter can be sealed to prevent tampering Connection of the wires should be done in accordance with the following connection diagram DMMeteringg 2011 28 User manual 0014 1 phase line in 3 phase line out 4 neutral line in 6 neutral line out 20 and 21 Pulse output contact 1 11 Operation Consumption indication There is a two color LED on the front panel of the meter When the meter is powered on and no load is connected to it the LED lights up green When power is consumed the LED will flash red The faster the LED flashes the more power is consumed For this meter the LED will flash 1000 or 2000 times per kWh depending on the version of the meter see section 1 3 for details Please note There are two versions of this meter with a difference in how reverse current is handled One version counts up in both directions and one only counts up in one direction and doesn t count in the other direction This has an effect if the meter is connected in reverse terminal 3 Load in and terminal 1 load out or used with any sort of energy production system solar panels wind generators etc See section 1 3 for details R
5. registered trademark of Inepro Metering member of the Inepro Group Other names appearing in this manual may be trademarks of third parties and are property of their respectful owners 1 2 Foreword Thank you for purchasing the DMMetering PRO1 series DIN rail single phase two wire energy meter The DMMetering PRO1 series energy meter is the most advanced type electronic kWh meter available at the market With the DMMetering product range we have introduced a large scale of energy meters on the market suitable for 110V AC to 400V AC 50 or 60Hz Besides the normal energy meters we also developed our own pre paid energy and water meters with chip card or infrared card and a complete PC management control system For more information on other products please contact our sales department at Sales ineprometering com or info inepro com hk Although we produce the DMMetering PRO1 series meter according to the requirements of IEC 62053 3 and our quality inspection is very accurate there might always be a possibility that your product shows a defect or failure for which we do apologize Under normal conditions your product should give you years of trouble free operation In case there is a problem with the energy meter you should contact your dealer immediately All energy meters are sealed with a special seal Once this seal is broken there is no possibility to claim any warranty Therefore NEVER open an energy meter or break the seal of the energy meter
6. RO1 series is labeled as follows PRO1D TE V11 xxx L__ Pulse led and pulse output 1 1000 impulses kWh 2 2000 impulses kWh Reverse counting 1 Does not count when energy is reversed 2 Counts up regardless of energy direction Type of display 1 LCD without backlight PRO1D 2 LCD with backlight PRO1D 3 Mechanical register PRO1ITE 1 5 Performance criteria Operating humidity Storage humidity Operating temperature Storage temperature International standard Accuracy class Protection against penetration of dust and water Insulating encased meter protective class 1 6 Specifications Meter type Nominal voltage Un Operational voltage Insulation capabilities AC voltage withstand Impulse voltage withstand Basic current Ib Maximum rated current Imax Max current for direct wire connection Max current for busbar connection Operational current range Peak current withstand Operational frequency range Internal power consumption Test output flash rate RED LED Pulse output rate pins 20 amp 21 Consumption indicator RED LED 75 95 10 C 50 C 30 C 70 C EN 50470 3 1 lt lt IP51 II PRO1 series 230V AC 161 300V AC 2KV for 1 minute 6KV 1 2uS waveform 5A 45A 32A 45A 0 4 Ib Imax 30Imax for 0 01s 50Hz 10 lt 2W 10VA 1000 or 2000 imp kWh see section 1 3 1000 or 2000 imp kWh see section 1 3 Flashing at load running User
7. e injury e Make sure the protection cover is placed after installation e Installation maintenance and repair should only be done by qualified personnel DMMeteringg 2011 22x User manual 0014 e Never break the seals to open the front cover as this might influence the functionality or accuracy of the meter and will void all warranty e Do not drop or allow physical impact to the meter as there are high precision components inside that may break and render the meter measurement inaccurate Exclusion of liability We have checked the contents of this publication and every effort has been made to ensure that the descriptions are as accurate as possible However deviations from the description cannot be completely ruled out so that no liability can be accepted for any errors or omissions in the information given The data in this manual is checked regularly and the necessary corrections will be included in subsequent editions If you have any suggestions please let us know Subject to technical modifications without notice Copyright Copyright Inepro Metering March 2011 All rights Reserved It is prohibited to pass on or copy this document or to use or disclose its contents without our express permission Any duplication is a violation of the law and Subject to criminal and civil penalties All rights reserved particularly for pending or approved patents award or registered trademarks Registered trademarks DMMetering is a
8. eading the meter The PRO1 series meter can be delivered with either a digital or mechanical register See the version numbering in section 1 3 Digital register The PRO1D series energy meter is equipped with a 5 2 digit LCD which is used to record consumption and can t be reset to zero The display has 5 digits before and 2 decimals after the dot on the display The reading accuracy is 1 100 kWh Mechanical register The PROTE series energy meter is equipped with a mechanical 5 1 register which is used to record consumption and can t be reset to zero Five decimals are marked with black color and one decimal is marked with red The reading accuracy is 1 10 kWh Pulse output The PRO1 series DIN rail energy meter is equipped with a pulse output which is optically isolated from the inside circuit It generates pulses in proportion to the measured consumption for purpose of remote reading or accuracy testing The pulse output is a polarity dependant open collector transistor output requiring an external voltage source for correct operation For this external voltage source the voltage Ui should be lower than 27V DC and the maximum switching current Timax is 27MA To connect the impulse output connect 5 27V DC to connector 20 collector and the signal wire S to connector 21 emitter The pulse output depends on the version and is either 1000 or 2000 impulses per kWh See section 1 3 for details regarding the impulses per kWh DMMeteri
9. it breaker or other overcurrent protection device used in the circuit An external switch or a circuit breaker should be installed on the supply wires which will be used to disconnect the meter It is recommended that this switch or circuit breaker is placed near the meter because that is more convenient for the operator The switch or circuit breaker should comply with the specifications of the building s electrical design and all local regulations An external fuse or thermal cut off which will be used as an overcurrent protection device for the meter must be installed on the supply side wire and it is recommended that this protection device is near the meter since that is convenient for the operator The overcurrent protection device should comply with the specifications of the building s electrical design and all local regulations This meter can be installed indoor or outdoor enclosed in a meter box which is sufficiently protected subject to local codes and regulations TO prevent tampering an enclosure with a lock or a similar device can be used The meter has to be installed against a fire resistant wall The meter has to be installed in a well ventilated and dry place The meter has to be installed in a protective box if the meter is exposed to dust or other contaminants The meter can be installed and used after being tested and can be sealed afterwards The meter can be installed on a 35mm DIN rail The
10. manual 0014 1 7 Basic errors 0 05Ib O 1Ib O 1Ib Imax O 2Ib Imax 1 8 Description m OOW DY Material Register Case Terminal block Protection cover 1 9 Dimensions Height Width Depth Weight DMMetering g 2011 Cos m 1 1 5 Cos 0 5L 1 5 Cos 0 8C 1 5 Coso 1 1 0 Cos 0 5L 1 0 Cos 0 8C 1 0 Register Terminal block Case Protection cover Security wire slot PC inflammable plastic ABS inflammable plastic ABS inflammable plastic ABS inflammable plastic C B 18 A i wo T 35 91 117 5 D E 117 5 mm 18 mm 58 5 mm 0 12 Kg net 7 User manual 0014 Turn off and if possible lock all sources supplying the energy meter and the equipment that is connected to it before working on it Always use a properly rated voltage sensing device to confirm that power is off Installation should be performed by qualified personnel familiar with applicable codes and regulations Use isolated tools to install the meter Fuse or thermal cut off or single pole circuit breaker should be fitted on the Supply line and not the neutral line The meter s casing is sealed if not properly looked after this seal could be broken voiding the warranty and damaging the meter We recommend that the connecting wire which is used to connect meter to the outside circuit should be sized according to local codes and regulations for the maximum amount of current of the circu
11. ng wires to the connected in meter clamp 3 should be reverse in case of a connected to load in and clamp 6 reverse enabled to load out meter See section 1 10 for details Maybe there is a Please contact technical support fault inside the for a meter replacement meter The register doesn t Is there almost no Check if the consumption led is count load on the meter blinking see above 200 flashes of the LED equals 0 1kWh or O 2kWh and should be clearly visible on the display Maybe there is a Please contact technical support fault inside the for a meter replacement meter No pulse output Is DC power Check the external voltage source connected to the Ui is 5 27V DC meter Is the pulse output Check correct connection connected connect 5 27V DC to connection correctly 20 collector and the signal wire S to connection 21 emitter Maybe there is a Please contact technical support fault inside the for a meter replacement meter Pulse output rate Maybe there is a Please contact technical support wrong fault inside the for a meter replacement meter DMMeteringg 2011 11 User manual 0014 1 13 Technical support For questions about one of our products please contact The Inepro Metering dealer in your region Your local Inepro Metering distributor Email support ineprometering com www ineprometering com 5 RoHS 2002 95 EC Hy DMMeteringg 2011 12 User manual 0014
12. ngg 2011 O User manual 0014 DMMeteringg 2011 During repair and maintenance do not touch the meter connecting clamps directly with your bare hands with metal blank wire or other conducting material as that will cause an electric shock and possibly cause injury Turn off and if possible lock all sources supplying the energy meter and the equipment that is connected to it before opening the protection cover before working on it Turn off and lock out all power supply to the energy meter and the equipment to which it is installed before opening the protection cover to prevent the hazard of electric shock Maintenance or repair should only be performed by qualified personnel familiar with applicable codes and regulations Use insulated tools to maintain or repair the meter Make sure the protection cover is in place after maintenance or repair The meter s casing is sealed if not properly looked after this seal could be broken voiding the warranty and damaging the meter 10 User manual 0014 Problem check Solution The consumption Is there any load Only if there is a load on the meter LED is not flashing connected to the will this LED flash PULSE LED meter If the load is very low the time Is the load on the between 2 flashes is very long line very low This can be mistaken for a broken meter As a test an electric water boiler 1L600W should make it blink once every second Is the meter Swap the connecti
13. rding electrical installations and are allowed to work on these installations according to the local regulations are considered qualified personnel in this manual Use for the intended purpose The equipment device module may only be used for the application cases specified in the catalog and the user manual and only in connection with devices and components recommended and approved by Inepro Metering B V Proper handling The prerequisites for perfect reliable operation of the product are proper transport storage installation and connection as well as proper operation and maintenance When operating electrical equipment certain parts of this equipment carry dangerous voltages Improper handling can therefore result in serious injury or material damage Only use isolated tools suitable for the voltages the meter is used for Do not connect while the circuit is energized current is running Do not connect the meter to a 3 phase 400VAC network Place the meter only in dry surroundings Do not mount the meter in an explosive area or exposed to dust mildew and or insects Make sure the used wires are suitable for the maximum current of this meter e Make sure the AC wires are connected correctly before activating the current voltage to the meter e Do not touch the meter s connection clamps directly with your bare hands with metal blank wire or other conducting material as that will cause an electric shock and possibly caus
14. ring point as received energy irrespective of the real energy direction or 2 registration with reversal preventing device The energy meter meets the requirements of Directive 2004 22 EC of the European parliament and the council of 31 March 2004 on measuring instruments Certification was based on compliance with the following harmonised standards EN 50470 1 2006 EN 50470 3 2006 Valid until Electricity metering equipment a c part 1 General requirements tests and test conditions Metering equipment class indexes A B and C Electricity metering equipment a c part 3 Particular requirements Static meters for active energy class indexes A B and C June 11 2020 The results are recorded in thefollowing annex test report 70965037 TDT 6356 10 G 4 ir P J J G Nabuurs Managing Director The investigation reported here does not confer any right to use an approbation mark granted by KEMA Integral publication of this certificate and adjoining reports is allowed pan This certificate is issued provided that neither KEMA nor the RvA assumes any liability KEMA Nederland B V Utrechtseweg 310 6812 AR Arnhem The Netherlands P 0 Box 9035 6800 ET Arnhem The Netherlands T 31 0 26 3 56 2215 F 31 0 26 4 42 6211 C amp M kema com www kema com trade register Arnhem 09080262 DMMetering 2011 Experience you can trust 5 User manual 0014 DMMeteringg 2011 1 4 Type number table The P
15. s are recorded in the following annex test report 2113897 TDT 6319 10 KEMA Quality B V a ir P J J G Nabuurs Managing Director Notified body number 0344 The investigation reported here does not confer any right to use an approbation mark granted by KEMA Integral publication of this certificate and adjoining reports is allowed This certificate is issued provided that neither KEMA nor the RvA assumes any liability KEMA Nederland B V Utrechtseweg 310 6812 AR Arnhem The Netherlands P O Box 9035 6800 ET Arnhem The Netherlands T 31 0 26 3 56 2215 F 31 0 26 4 42 6211 KAL kema com www kema com handelsregister Arnhem 09080262 Experience you can trust DMMetering 2011 4 User manual 0014 CERTIFICATE EC Type examination certificate 6356 10 Manufacturer Contact person Address Postal code Place Country Instrument Mark Type Register Accuracy Class Measurement range Temperature range Use Protection Class Environmental class Registry method Inepro Metering BV D van der Vaart P O Box 92 2450 AB Leimuiden The Netherlands Electronic single phase two wire energy meter Direct connected PRO 1TE Mechanical B 230 V 5 45 A 50 Hz 1000 or 2000 imp kWh 10 40 C Indoor II M1 E2 2 options are available by selection per interconnection of soldering islands 1 bidirectional method with always positive register the meter always counts the energy of the measu