1. e Select the stream source Multicast or Unicast and the network interface to use o For Unicast enter the port to listen on o For Multicast enter the address and port e Then click on the Save button see Figure 10 e The new settings will be effective after a reboot e If there is a stream currently available the status section will show green for Enabled Signal Lock and Status The program list will also be displayed on the right hand side of the interface a 1e100 1 LE100 or 1420 Serial Number LE1 000001 root Administrator OVERVIEW ADMINISTRATION CONTROL MONITORING LOGOUT O Select the desired input Change the settings and click on Save button to save the configuration ry L Content Feed Manager M Network index 10 neto Output Configuration Enabled Name net0 Signal Lock Multicast UDP IP a 230 0 0 1 1234 eth1 Source Program Video Audio Subtitles Figure 10 Input Configuration Network LE1 0M 002066 DRM Page 22 of 52 Version 1 1 Doremi Labs 7 2 Satellite Input Configuration LE100 SR For LE100 SR due to the presence of Satellite card equipment is intended to be installed by a service person and has installation instructions that require the equipment to be connected to a socket outlet with a protective earthing connection If you are using the LE100 SR with a satellite tuner installed you must also configure the satellite inputs for live streaming Note These
2. Le RECORD_FTR 2D_51_20140306150308 E ion 240 minutes of record v2 Figure 20 Record Set Up e Choose the feed source Network or Satellite Note The satellite source is only displayed on LE100 SR or if the correct satellite board is properly installed Select the appropriate Program Video Audio and Subtitle ID s from the incoming stream Enter the desired name duration and type of recording in the Record Setup window If the stream is 2D leave the 3D mode set to auto detect If the stream is 3D select the appropriate 3D format e Select the Record button The LE100 will recognize the live stream and begin saving the stream to the internal hard drive The LE100 will load the recording into the player but it does not automatically O start playback o If the Playback window shows Waiting for Signal there may be a problem with the stream format or the network setup LE1 0M 002066 DRM Page 34 of 52 Version 1 1 Doremi Labs e The user can use the play pause skip forward or skip backward buttons to control playback e f playback of a current recording is paused the location bar can be selected and dragged to navigate to a specific part of the video and resume playback e Also while paused the current timecode field can be selected and a desired timecode can be entered to locate to e f desired a different clip that already resides on the hard drive can be loaded and played back without
3. 59 94fps 60fps 17 5 Input File Format Support via USB or Ethernet e DCP files MPEG2 H 264 VC1 e Transport Stream LE1 0M 002066 DRM Page 49 of 52 Version 1 1 Doremi Labs 17 6 Video Outputs e 23G SDI SMPTE 259M SMPTE 292M SMPTE 424M e 2 HDMI 1 4 17 7 Audio e 8CH Embedded HDMI SDI e 8CH unbalanced AES EBU 4x BNC e 2CH Analog stereo 3 5mm audio jack e 16 20 or 24 bit PCM 48 kHz e Compressed audio Dolby Digital AC 3 pass through 17 8 Control e Input Output Ethernet e Odetics Protocol 17 9 Physical Characteristics e 1 Rack Unit 1 75 x 19 x 13 44mm x 483mm x 330mm e Weight 10 5 lbs 4 8 kg 17 10 Power e Power Supply 80 PLUS certified e Voltage AC 100 240 V e Current 1 5 to 3 5 A e Frequency 60 to 50 Hz e Total DC Output 250 W e Idle Consumption 28W e Peak Consumption 41W LE1 0M 002066 DRM Page 50 of 52 Doremi Labs Version 1 1 18 Acronyms Term Description CLI Command Line Interface DCP Digital Cinema Package FTP File Transfer Protocol GUI Graphical User Interface LE Live Event SSH Secure Shell Terminal LE1 0M 002066 DRM Page 51 of 52 Doremi Labs Version 1 1 19 Document Revision History Date Revision Description 03 19 2014 1 0 First version of document 08 12 2014 1 1 Differences between LE100 and LE100 SR clarified LE1 0M 002066 DRM Page 52 of 52 Doremi Labs Versi
4. the output of either satellite input This is controlled on the Network Streamer page e Log into the LE100 Web GUI go to the Control tab and click on the Network Streamer link on the left side of the GUI see Figure 26 e Select the desired network output o The network outputs can be configured interface IP address port on the Input Feed Manager Output Configuration page see Section 7 e Then choose the input stream in the source select box Note The satellite sources are only displayed on LE100 SR or if the correct satellite board is properly installed e Next select the desired program video audio and subtitles e Settings are automatically saved when modified e f the source settings are valid the Input Status will display green for Running Signal Lock and Status e The stream will be available once the Start button is selected e To stop outputting the transport stream select the Stop button Network Streamer Link a doremi oa z fersion 1420 Serial Number LE1 000001 root Administrator OVERVIEW ADMINISTRATION CONTROL MONITORING LOGOUT roy Ro CineLister Select the desired network output then choose the input stream in the source select box the desired program video audio and subtitles Settings are automatically saved when settings are modified You can configure the output interface IP address port on the page Input Feed Manager Network 10 neto Network
5. 10 net Running 8 32 Custom PID SignalLock Status 33 Custom PID 36 Custom PID Wies 0 Custom PID reo Enabled Running Status Figure 26 Network Streamer Start Stop Stream Buttons LE1 0M 002066 DRM Page 41 of 52 Version 1 1 Doremi Labs 12 5 1 Verifying Streaming Output The transport stream output of the LE100 can be verified using VLC media player e Set the Multicast Address in the output configuration Section 7 3 to the address of the machine running VLC media player e Launch VLC and from the media menu select Open Network Stream e Inthe network URL field enter udp 5004 replacing 5004 with the port number you have specified in the output configuration see Figure 27 e Select play and the stream should begin to play in the VLC media player pe disc 52 Network HER Capture Device Network Protocol Please enter a network URL udp 5004 http www example com rtp 6 1234 mms mme examples com rts p server example org 8080 test sdp http www yourtube com watch 7 Show more options Figure 27 VLC media player LE1 0M 002066 DRM Page 42 of 52 Version 1 1 Doremi Labs 13 Logging Out of the LE100 To log out of the LE100 follow the steps below e From any tab in the Web GUI scroll over to the Log Out button in the top right corner e Click on the Log Out button see Figure 28 o Logging out will only disconne
6. 2 1 IP Configuration To change the IP address of either ethO or eth1 first make a backup of the file interfaces located in the directory etc network Then run the following command and make necessary changes e rwdo nano etc network interfaces Note If you are unsure on how to use the command line editor contact Doremi Cinema Technical Support for assistance 5 2 2 Servers Optional To add a new NTP server type the following command e rwdo nano doremi etc ntpservers lt enter gt e Then add the url or ip of the NTP Server after NTPSERVERS separating servers with a space e exp NTPSERVERS pool ntp org 100 57 37 135 5 2 3 DNS Required for NTP To add a new line to your DNS type the following command e echo nameserver 172 17 16 1 gt gt etc resolv conf lt Enter gt LE1 0M 002066 DRM Page 18 of 52 Version 1 1 Doremi Labs 5 3 Network Configuration via USB This method should be used to rescue the device in case the IP address is lost or forgotten To update the network configuration with a USB flash drive Create a directory doremi at the root of the USB key Create a directory update inside the doremi directory Create a directory network inside the doremi update directory Create a text file inside the network directory and name it ifconfig 0 This will be used to configure Ethernet port 0 For static IP enter the following information in the ifconfig 0 fil
7. 49 LE1 0M 002066 DRM Page 3 of 52 Version 1 1 Doremi Labs E o RE EE 49 17 4 Output Video Formal ist ti 49 17 5 Input File Format Support via USB or Ethernet eect terre eeeeenneeeeeeeeeeteeee 49 1720 IESSE 50 TAT AMOO nO E Ss 50 17 8 Controles 50 17 9 EIERE EEN EE ENEE EE 50 Seet E EE 50 18 AGIKONYINS EE 51 19 Document REVISION MISION ascii cli lidia 52 LE1 0M 002066 DRM Page 4 of 52 Version 1 1 Doremi Labs Software License Agreement The software license agreement can be found at the following location http www doremilabs com support cinema support cinema warranties Hardware Warranty The hardware warranty can be found at the following location http www doremilabs com support cinema support cinema warranties LE1 0M 002066 DRM Page 5 of 52 Version 1 1 Doremi Labs WARNING 1 e THIS DEVICE MUST BE GROUNDED _ IMPORTANT Power requirements for electrical equipment vary from area to area Please ensure that the LE100 meets the power requirements in the surrounding area If in doubt consult a qualified electrician or a Doremi Labs dealer Power Ratings e Power Supply 80 PLUS certified e Voltage AC 100 240 V e Current 1 5 to 3 5 A e Frequency 60 to 50 Hz e Total DC Output 250 W e Idle Consumption 28W e Peak Consumption 41W WARNING Multiple sources of supply Disconnect all sources before servicing Rack Mount and Thermal Information e Maximum operating ambient temperature
8. 8 2 Audio Dels LE1 0M 002066 DRM Page 2 of 52 Doremi Labs Version 1 1 A A Ee Ee 27 10 Autostart Playba K aora 28 11 ACCOUNL Manaus id a adele a E R T 29 11 1 Adding a New User e EE 29 11 32 Elle eege dee SN al 30 11 3 Delete an Existing User tooo adi 30 12 70 19 0 eee a EE ENEE ENEE 31 121 Ginelistor Play Dak ts conil 31 12 131 Playing a Live Stream uti 32 12 1 2 Recording a Live Stream escindida dtnea sia 34 12 2 Ginelister EMO ia nas 35 12 2 1 Playing a Single Clip from the Disk oooonooonccccnnnccinnnccooccccnnncconannnnancccnnnnnnnnnnnnnnnnnos 35 122 2 GEARING a EE 36 12 23 Scheduling PlayDack iii 38 KE ee EE 38 12 4 Coment Manada o do 39 124 1 Viewing Asset Properties AAA 39 12 4 2 Deleting AMAS EEN EE 40 12 5 Network Ste amerindias ad 41 125 1 Verifying Streaming Olite 42 13 Logging Outro the LETOO aa cli 43 14 Shutting Down or Restarting the LEIDO cuidas 44 15 Updating the LE100 Software and Firmware ccoccccccnnncnoooccnnnncccnnnnnnnnncnnnnnnnnnnnnnnnncnnnnnnns 45 15 1 Software Update via Web GU EEN 45 15 2 Software Update via FTP Clics aa ia pde 46 15 3 Verifying the Software Update AAA 46 16 A A ath ae eet De ete Ge hs aed eats aaa tek cus 47 16 1 Generating a Report via GU ENEE 47 16 2 Generating a Report via CLI sca eee cea a ake es Ai ae ae age 48 16 3 Generating a Report via USB scans diia cis ii dad 48 17 Hardware Specifications vii 49 df 1 Man EE 49 17 2 HDI SD DECO vita ia
9. Format and Video Output Layout settings are ignored when using SENSIO content Click on Save to save the new configuration It will be effective with the next clip that is loaded Dual HDMI e Click on Save to save the new configuration It will be effective with the next clip that is loaded Figure 15 Video Output Configuration LE1 0M 002066 DRM Page 27 of 52 Version 1 1 Doremi Labs 10 Autostart Playback A Show Playlist can be chosen to automatically play whenever the LE100 is started The LE100 can also be configured to begin live streaming when the LE100 is powered on To configure Autostart Playback go to the Administration tab of the Web GUI and select Control Panel From the Control Panel select Autostart Playback see Figure 16 Select the Autostart mode o None nothing automatically plays upon startup o Live with latest configuration LE100 streams most recent configuration upon startup o ShowPlaylist LE100 plays selected show playlist upon startup If using ShowPlaylist mode select the desired Show Playlist from the drop down list see Section 12 2 2 for more information about creating playlists Select the playlist behavior from the mode drop down list o Play plays the playlist once and stops at the end o Loop plays the playlist repeatedly until stopped manually o Play then Rewind plays the playlist once to the end and then re cues it to the beginning o Play then Eject plays the playlist once to
10. Version 1 1 Doremi Labs 7 3 Output Configuration In order to output a transport stream from the LE100 the network output settings multicast address port and interface must be configured e Goto the Administration tab click on the Control Panel link followed by the Input Feed Manager link e Under Output Configuration select net 10 or net 9 depending on which output you wish to configure see Figure 12 Note net 10 and net 9 are the default names for the network ports These can be renamed as desired e Enable Disable the network output by selecting Yes or No e Enter the multicast address and port and then select the correct Ethernet port ethO or eth1 e Click on the Save button to commit the changes Output Configuration a 1e100 1 LE100 m 1428 Serial Number LE1 000001 root Administrator OVERVIEW ADMINISTRATION CONTROL MONITORING H Select the desired output Content Fe i Manage Fi x 5 e y WA Manai Change the settings and click on Save button to save the configuration 4 Input Con ration Network index 10 Name net 10 E Terminal 10 11 24 221 1234 eth Figure 12 Output Configuration LE1 0M 002066 DRM Page 24 of 52 Version 1 1 Doremi Labs 8 Audio Configuration 8 1 Headphone Volume The volume level of the front panel analog audio jack can be adjusted using the web interface e Log into the LE100 Web GUI and go to the Administration tab e Inthe A
11. set the proper privileges for the user account The following privileges are available o Inactives o Ingests o Projectionist Projectionist is a standard user allowed to use the Doremi applications present on the unit without changing the configuration o Show Manager In addition to Projectionist s privileges a Show Manager user is allowed to ingest and delete content LE1 0M 002066 DRM Page 29 of 52 Version 1 1 Doremi Labs o SuperUser In addition to Show Manager s right a SuperUser has the privileges to configure the unit For example the SuperUser can update the firmware and software o Administrator An Administrator user will be a user in the group of root The Administrator can perform all of the privileges listed above in addition to creating modifying and deleting user accounts Select the Login type There are two different login types available o Virtual Virtual user account only works with Doremi applications o System Regular Linux user account that can be used anywhere on the system For example on Linux terminal windows Define the password by entering into the Password field and confirm the password by re entering the password in the Confirm field Note The user will be provided information about the strength of the chosen password e Select the Save button to finalize creation of the new user account 11 2 Edit an Existing User e To edit an existing user account click on the Login name in the A
12. the available DCP s or DLM s will appear in the list o If the list is not automatically updated use the Refresh button e Select the desired elements to ingest and then select the Ingest button e The view will automatically switch to the Ingest Monitor window where the user can view the progress of the ingest pause the ingest resume the ingest or cancel the ingest Ingest Scan Refresh Ingest Link Button B al Toi le100 1 o 1420 Serial Nu nber LE1 000001 ev root Administrator ADMINISTRATION CONTROL MONITORING Local Storage all elements Select Unselect all jo st scanned about 7 minutes ago e Doemg 3D FramePacking TB_720p50_h264_50Mb Generated by CineAsset Version 6 2 6 Doremi_3D_FramePacking_1B 72060 h264_50Mb PKG s 0 DLM s 0 Scan Location Figure 24 Control Tab Ingest Manager Menu 12 4 Content Manager Content Manager is used to view the assets stored on the LE100 view the assets properties and also delete unwanted assets 12 4 1 Viewing Asset Properties e To see the properties of a particular asset log into the LE100 Web GUI and go to the Control tab LE1 0M 002066 DRM Page 39 of 52 Version 1 1 Doremi Labs e Click on the Content Manager link and then the Composition Playlist link on the left side of the GUI see Figure 25 e Single click on top of the name of the asset you wish to examine and the CPL Information window will appear e The CPL Information Setti
13. the end and then unloads the playlist Select the Save button to commit the settings The new settings will take effect the next time the LE100 is rebooted a le100 1 LE1 00 ion 1420 Serial Number LE1 000001 root Administrator OVERVIEW ADMINISTRATION CONTROL MONITORING LOGOUT Select a show playlist below that will automatically be played at system start up Autostart ShowPlaylist ShowPlaylist Show Playlist 1 Mode Loop ShowPlaylist Information Figure 16 Control Panel Autostart Playback LE1 0M 002066 DRM Page 28 of 52 Version 1 1 Doremi Labs 11 Account Manager The Account Manager allows the user to add remove edit user accounts e To access the Account Manager select the Administration tab followed by the Control Panel and then Account Manager see Figure 17 a eel 1e100 1 LEI 00 Su 1 420 Serial Number LE1 000001 ev root Administrator OVERVIEW ADMINISTRATION CONTROL MONITORING LOGOUT de New Group SuperUsers Projectionists Projectionists Ingests ShowManagers Administrators Figure 17 Control Panel Account Manager 11 1 Adding a New User Account e To add a new user account click on the New button e Enter the username to be used for log in in the Login field and the associated Full Name used to describe the user Both names will be displayed in the Account Manager window after the new user addition is completed e Select the Group This will
14. H 264 DCP s created with Doremi Content Manager software can be ingested via USB All content on the LE100 is stored on the internal hard drive and video decoding is performed by the hardware The LE100 can output directly to a display device through HDMI or 3GSDI LE100 s can also re distribute or forward the incoming stream to other devices via Ethernet Configuring the LE100 network consists of three methods which includes the Web GUI Command Line Interface CLI and USB flash drive mainly used to rescue the device in case of a system failure Note For the purpose of this manual everything applicable to the LE100 model is also applicable to the LE100 SR model unless indicated otherwise 2 1 Device Overview The LE100 has several ports on the back panel that perform specific functions e 2x HDMI Out e 2x 3G SDI Out e 4x AES Digital Audio Out e 2x USB Ports e 2x Ethernet Ports e Serial Port Ethernet Ports O and 1 UE al Wi Law J i e n O mun TR nuuuunnno lo E CA eee gi SYNC IN sor OUTA so con B E ei 2 Figure 1 LE100 Back Panel I Os LE1 0M 002066 DRM Page 9 of 52 Version 1 1 Doremi Labs CAM Card 2x Satellite Slots Input E CELL all Figure 2 LE100 SR Back Panel l Os The LE100 has several front panel controls that include e 3 5mm Analog Audio Jack e USB Port e Activity LED e Power LED e Reset Button e Power Butto
15. an the LE100 This can damage the unit Modification of this equipment is dangerous and can result in the functions of the LE100 being impaired Never attempt to modify the equipment in any way In order to ensure optimum performance of the LE100 select the setup location carefully and make sure the equipment is used properly Avoid setting up the LE100 in the following locations e Ina humid or dusty environment e Inaroom with poor ventilation e On a surface which is not level e Inside a moving vehicle where it will be subject to vibration e In an extremely hot or cold environment Caution e Battery is located on the motherboard e Danger of explosion if battery is incorrectly replaced e Replace only with the same or equivalent type recommended by the manufacturer e Dispose of used batteries according to the manufacturer s instructions For LE100 SR due to the presence of Satellite card equipment is intended to be installed by a service person and has installation instructions that require the equipment to be connected to a socket outlet with a protective earthing connection LE1 0M 002066 DRM Page 7 of 52 Version 1 1 Doremi Labs 1 Introduction 1 1 Purpose This manual explains how to set up and use the Doremi Labs LE100 device 1 2 Software Version The current versions that this manual pertains to are software version 1 4 2 firmware 1 2 1 and above 1 3 Materials Required e Computer e Ethernet Cable e USB Flash Drive opt
16. before the video by the time selected in milliseconds The recommended setup that matches almost all setup is 80 ms 200 ms Selected audio delay is 0 ms Audio Delay Figure 14 Audio Delay Slider LE1 0M 002066 DRM Page 26 of 52 Version 1 1 Doremi Labs 9 Video Configuration e There are several settings to determine how the video is output from the LE100 To adjust the video output settings log into the LE100 Web GUI and go to the Administration tab e Select the Control Panel and click on the Video Configuration link see Figure 15 e Use the drop down menus to select The desired video format 1920x1080 60Hz 1280x720 60Hz or Native The desired layout Progressive or Native The desired HDMI mode HDCP active or HDCP inactive The desired HDMI color space The desired HDSDI color space The desired 3D output mode Dual HDMI HDSDI Single HDMI Frame Packing or Native O O O 70O 0 O Note The Video Output Format and Video Output Layout settings are ignored when using SENSIO or RealD content e Click on Save to save the new configuration The new configuration will be effective with the next clip that is loaded 1e100 1 LE1 00 ion 1 4 20 Serial Number LE1 000001 root Administrator OVERVIEW ADMINISTRATION CONTROL MONITORING LOGOUT 1920 x 1080 60Hz HDMI Output HDCP inactive Progressive Video HDMI Output Color Space RGB standard Video SDI Output Color Space YCbCr 709 The Video Output
17. ccount Manager user list e The edit user dialog will appear allowing you to edit the necessary fields Click Save when finished editing 11 3 Delete an Existing User e To delete and existing user account click the X on the right hand side of the user list e The user will be asked for a confirmation Clicking Yes will delete the user account LE1 0M 002066 DRM Page 30 of 52 Version 1 1 Doremi Labs 12 Control In the Control tab users can manage content and control recording and playback CineLister is used to build playlists and control recording and playback Ingest Manager is used to ingest content and licenses Content Manager is used to view and edit the properties of content as well as to delete assets 12 1 CineLister Playback e The CineLister Playback window is the primary way to control recording and playback on the LE100 To access the playback controls log into the LE100 Web GUI and go to the Control tab e Click on the CineLister link on the left side of the GUI see Figure 18 Current Control Option Timecode Links Serial Number LE1 100001 OVERVIEW Jump to Live 00 01 23 00 01 23 Record Live Start Stop Button Buttons LE1 0M 002066 DRM Control Tab ADMINISTRATION CONTROL MONITORING AA iey remaining 00 00 14 remaining 00 00 14 Kc Figure 18 Control Tab Playback Page 31 of 52 Doremi Labs le100 1 1420 root Administrator 9 Trans
18. ct the web interface from the LE100 Logging out does not shut down the LE100 or interrupt any current operations a 1e100 1 LE100 sol iain 1428 Serial Number LE1 000001 Us root Administrator OVERVIEW ADMINISTRATION CONTROL MONITORING LOGOUT F Detailed Report Chassis Networking Product name IP Address eth0 0 0 0 0 Serial number IP Address eth 192 168 9 10 Base board Clock Versions System clock Thu Mar 06 2014 15 30 51 Firmware version Timezone America Los_Angeles Software version UTC Offset 480 minutes WebUI version Next DST change Sun Mar 9 01 59 59 2014 PST Booting Device Model USB EDC InnoDisk Capacity 3 83 GB Figure 28 Log Out LE1 0M 002066 DRM Page 43 of 52 Version 1 1 Doremi Labs 14 Shutting Down or Restarting the LE100 e To shut down the unit select the red Shutdown Restart button in the upper right hand portion of the interface Then click on the shutdown button e Alternately go to the Administration tab and click on the System link on the left Then click on the Shutdown button see Figure 29 Note After pressing the Shutdown button a warning will appear giving the user five 5 seconds to cancel the shutdown process If the user wants to shutdown the unit simply let the process continue e To restart the unit select the red Shutdown Restart button in the upper right hand portion of the interface Then click on the Restart button e Alternately go to
19. dministration tab select the Control Panel and click on the Audio Configuration link e Click and drag the volume control slider right or left to increase or decrease the volume level see Figure 13 The Save button must be pressed to commit the level change Volume Audio Dela Control Slider y a 0 1 420 Serial Number LE1 000001 root Administrator OVERVIEW AD NISTRATION CONTROL MONITORING LOGOUT Headphone Volume 33 dB Figure 13 Headphone Volume 8 2 Audio Delay The audio configuration also allows the user to add a delay between the audio and video e Log into the LE100 Web GUI and go to the Administration tab e From the Administration tab select Control Panel and click on the Audio Configuration link This will take you to the Headphone Volume page For the Audio Delay settings select the Audio Delay link see Figure 13 e Use the audio delay slider to adjust the delay see Figure 14 LE1 0M 002066 DRM Page 25 of 52 Version 1 1 Doremi Labs e A positive value means the audio will be several milliseconds after the video e A negative value means the audio will be several milliseconds before the video 1e100 1 A 142 0 root Administrator OVERVIEW ADMINISTRATION CONTROL MONITORING LOGOUT You can add a delay between the video and the audio A positive value means the audio will play out after the video by the time selected in milliseconds A negative value means the audio will play out
20. doremi Technology Leadership for Digital Cinema LE100 User Manual Version 1 1 The English version of this document is the only legally binding version Translated versions are not legally binding and are for convenience only LE1 0M 002066 DRM Page 1 of 52 Version 1 1 Doremi Labs Table of Contents d a ee Le e y ara dida Tel o A a ee ac EE a oe 1 2 Software Version vna 1 3 Materials ROQUIrOd conil 1 4 Contact Informations Sse tom eg eta dirias EE 2 1 Device OVEIVIOW coccion 2 2 Media Formats Gupported AEN A deer a e E elon 3 1 Items to CONMQUIE vi 3 2 Hardware Gontiqur OM uecordii addict A Logging nto LEIDO Manera dns 4 1 Logging into the LE100 via Web GU 4 2 Logging into the LE100 via GH 4 3 Logging into the LE100 via Serial Port 5 Network Contfguraton ANEN 5 1 Network Configuration via Web GUI ooooonninncccccnnnccccnccanaccccnnncnns 5 1 1 Adding or Removing NTP Servers coocccconccooccccccnccccnnananoncnos 5 2 Network Configuration via Cl 5 2 1 EKOS Ns cora sin dat 5 2 2 Servers Optional ivi 5 2 3 DNS Required Tor Plans eege dial 5 3 Network Configuration via UP 6 Setting the Time and Date NEEN 6 1 Setting the Time and Date via Web GUI occcnnnnnnnnnnnnnnnnnnnnns 7 Input Feed RO e Scsi 7 1 Network Input CGontouraion 7 2 Satellite Input Configuration LE100 SR 0ooococcccnnnccnoncccnaccccnnnnnn 7 3 Output Configuration caviar ei A A nne 8 1 Headphone Volume tatiana oido
21. e replacing the items in bold with your desired settings o interface ethO o ip 192 168 9 10 o mask 255 255 255 0 o gateway 192 168 9 1 For DHCP use the following format o interface ethO o ip dhcp Create a second file inside the network directory and name it ifconfig 1 This will be used to configure Ethernet port 1 For static IP enter the following information in the ifconfig 1 file replacing the items in bold with your desired settings o interface eth1 o ip 192 168 9 10 o mask 255 255 255 0 o gateway 192 168 9 1 For DHCP use the following format o interface eth1 o ip dhcp optional Create a file and name it ntp with the following format Replace items in bold with your desired settings o NTPSERVERS server1 ntp org server2 ntp org optional Create a file and name it dns required for NTP with the following format Replace items in bold with your desired settings o Nameserver 172 17 16 1 o nameserver 8 8 8 8 o search rnd doremilabs fr o domain rnd doremilabs fr WARNING When creating these configuration files make sure that the files do not have any extensions e g txt doc which are the default for some operating systems LE1 0M 002066 DRM Page 19 of 52 Version 1 1 Doremi Labs e Place all files that were created into the doremi update network folder on the USB flash drive e On the LE100 plug your USB flash drive and wait for two minutes Unplug t
22. e successfully uploaded you will receive the message File successfully uploaded Click here to reboot Reboot the LE100 to complete the update Upload Link Control Tab LE100 Seca ape Serial Number LE1 000001 root Administrator OVERVIEW ADMINISTRATION CONTROL MONITORING LOGOUT 0 You can upload packages to upgrade the product or to install additional features Click on the input box below to select the packages you want to install A system reboot might be necessary to complete packages installation Upc cmt le 100_install 1 4 2 pkq Browse y Y d Y Figure 30 Software Update ET Choose File Button LE1 0M 002066 DRM Page 45 of 52 Version 1 1 Doremi Labs 15 2 Software Update via FTP Client e Make sure that an FTP client is installed on the computer e Turn the LE100 on and make sure it is able to ping to the network e Open the FTP client connect using the IP address of the LE100 with port 22 and login as the Admin user with the appropriate password e Upload the update package pkg file to the folder doremi etc rc once and then reboot 15 3 Verifying the Software Update To check if the upgrade was successful log into the Web GUI and the software version will be shown in the top right corner see Figure 31 or open an SSH session and type the following command tail doremi log update log and verify that the pkg file installed successfully Screen le 100 1 Software Versi
23. he flash drive and reboot Note The files on USB flash drive are never modified by the LE100 LE1 0M 002066 DRM Page 20 of 52 Version 1 1 Doremi Labs 6 Setting the Time and Date 6 1 Setting the Time and Date via Web GUI e Log into the LE100 Web GUI and go to the Administration tab e Click on the Control Panel link followed by Time Settings e Adjust the time and time zone to the desired configuration e Click on the Update button for changes to take effect Click both Update buttons if configuring the time and time zone See Figure 9 Note There is no need to reboot the unit when changing the time However a reboot is required when changing the time zone LE100 m 1420 Serial Number LE1 000001 root Administrator OVERVIEW ADMINISTRATION CONTROL MONITORING LOGOUT Current Date Thursday 06 March 2014 Current Time 14 19 39 Change time 14 19 20 Update Timezone America Los_Angeles Figure 9 Administration Time Settings LE1 0M 002066 DRM Page 21 of 52 Version 1 1 Doremi Labs 7 Input Feed Manager 7 1 Network Input Configuration To set up the LE100 for live streaming from a network input you must configure the input settings e Go to the Administration tab click on the Control Panel link followed by the Input Feed Manager link e Under Input Configuration select net0 to configure the network input Note ne is the default name for the network input This can be renamed as desired
24. ice e Connect the digital audio cable from the LE100 to the desired audio device LE1 0M 002066 DRM Page 11 of 52 Version 1 1 Doremi Labs 4 Logging into LE100 Once the hardware is set up and the PC s IP configuration is complete the user can use one of several methods to log into the unit Such as 4 1 Logging into the LE100 via Web GUI e First open a web browser and type the IP address of the LE100 o The default IP address for Ethernet port 1 of the LE100 is 192 168 9 10 o Set your computer s IP address in the range 192 168 9 xx with xx being in the range 2 254 except 10 when using default IP Note If the IP address was changed use the IP address that was assigned to the LE100 instead of the default IP e The following screen will appear Figure 4 Login Window e Type the username and password in the fields provided Figure 4 o Log in as admin o Default password for admin 1234 Note The admin password can be changed in the web interface or by using the following command and following the on screen instructions passwd e If the user wants to change the default language before logging in click on the Site Language button below the Login button e The following screen will appear LE1 0M 002066 DRM Page 12 of 52 Version 1 1 Doremi Labs Site Language m Espanol r Fran ais ER Portugu s _ Russian Chinese SS English Figure 5 Login Window Language Configuration e Selec
25. interrupting the live recording e To stop recording the incoming stream click the Record button and the Record Setup window will re appear Click the Stop button to stop the recording o The stream will be saved to disk and available for future playback 12 2 CineLister Editor In addition to playing and recording live streams the LE100 has the capability of playing back clips that are stored on the hard drive The CineLister Editor can be used to select single clips for playback as well as used to create playlists containing multiple clips 12 2 1 Playing a Single Clip from the Disk e To select a clip from the hard drive for playback log into the LE100 Web GUI and go to the Control tab e Click on the CineLister link followed by the Editor link see Figure 21 e Single clicking on a clip in the All Available Elements column will add that clip to the Show Playlist column Once the desired clip is listed in the Show Playlist switch back to the CineLister Playback control and press play see Figure 18 The clip will be cued and played e To play a different clip first eject the clip in the CineLister Playback window Then switch back to the CineLister Editor clear the list and select the new clip With the new clip in the Show Playlist view switch back to the CineLister Playback and press the play button LE1 0M 002066 DRM Page 35 of 52 Version 1 1 Doremi Labs CineLister Editor Available Clips Playlist Edi
26. ional e Serial cable optional e Power Cable included e FTP Client e Mozilla Firefox or Google Chrome Browser 1 4 Contact Information If in need of help or assistance please contact Doremi Labs Technical Services USA 24 7 Technical Services line 1 866 484 4004 Technical Services Email cinemasupport doremilabs com Europe 24 7 Technical Services line 33 0 492 952 847 Technical Services Link http support doremitechno org ticketing Japan Technical Services line 044 966 4855 Technical Services Email support doremilabs co jp Australia China India Indonesia Korea Malaysia New Zealand Philippines Singapore Taiwan Thailand Technical Services Email supportasia doremilabs com LE1 0M 002066 DRM Page 8 of 52 Version 1 1 Doremi Labs 2 Overview The LE100 is a device designed to receive record decode and distribute live MPEG2 or H 264 media streams There are two models available LE100 and LE100 SR LE100 accepts streaming media in an MPEG2 Transport stream via Ethernet In addition to Ethernet streams LE100 SR contains an optional satellite input and can receive DVB S DVB S2 signals via satellite feed Both LE100 models can save the incoming streams and wrap them in Digital Cinema Package DCP format It can record and play DCP s simultaneously allowing the user to play the files at a later time or move the DCP s to another screen for an encore performance Alternatively MPEG2 and
27. is 35 C or 95 F e Never restrict the air flow through the devices fan or vents e When installing equipment into a rack distribute the units evenly Otherwise hazardous conditions may be created by an uneven weight distribution e Connect the unit only to a properly rated supply circuit Reliable earthing grounding of rack mounted equipment should be maintained LE1 0M 002066 DRM Page 6 of 52 Version 1 1 Doremi Labs PROTECTING YOURSELF AND THE LE100 Never touch the AC plug with wet hands Always disconnect the LE100 from the power supply by pulling on the plug not the cord Allow only a Doremi Labs dealer or qualified professional engineer to repair or re assemble the LE100 Apart from voiding the warranty unauthorized engineers might touch live internal parts and receive a serious electric shock Do not put or allow anyone to put any object especially metal objects into the LE100 Only use an AC power supply Never use a DC power supply If water or any other liquid is spilled into or onto the LE100 disconnect the power and call a Doremi Labs dealer The unit must be well ventilated and away from direct sunlight To avoid damage to internal circuitry as well as the external finish keep the LE100 away from direct sources of heat heater vents stoves radiators Avoid using flammable aerosols near the LE100 They can damage the surface area and may ignite Do not use denatured alcohol paint thinner or similar chemicals to cle
28. n USB ACTIVITY Ca Gd a Audio Jack USB Activity LED Figure 3 LE100 Front Panel l Os and LEDs Power Button Reset Button Power LED 2 2 Media Formats Supported The media formats below are supported by the LE100 Video Format Resolution Frame Audio Maximum Record Rate s Bitrate and Play H 264 MPEG 2 1920 x 1080p 23 98 24 25 PCM 50 Mbps Yes VC 1 29 97 30 50 AC3 59 94 60 pass thru 1920 x 1080i 50 59 94 60 1280 x 720p 50 59 94 60 LE1 0M 002066 DRM Page 10 of 52 Version 1 1 Doremi Labs 3 Configuration 3 1 Items to Configure All the items mentioned below must be configured for the LE100 to work properly e Network configuration IP address Netmask Gateway Unicast or Multicast UDP IP O O O O 3 2 Hardware Configuration Before beginning the network configuration the user must set up the LE100 s hardware and cable connections e Once the LE100 is taken out of the package set it on a firm surface and connect the single power supply cable from the unit to a reliable power source e Connect an Ethernet cable from the LE100 to the desired network Depending on the specific setup and intended usage one or more of the following connections can be made e Connect a Serial port cable from the LE100 to the computer e Connect the HDMI cable from the LE100 to the display device e Connect the HDSDI cable from the LE100 to the display dev
29. ngs tab can be used to set the clips 3D format so that it always plays properly o Inthe Settings tab use the pull down menu to select the appropriate 3D mode and select Save CPL Information Window a doremi e100 Gen D Serial Number LE1 000001 root Administrator Composition Playlist OVERVIEW ADMINISTRATION CONTROL MO IITORING CPL Information Go CineList D Ingest V nager Assets Seltings Bum _in_8CH_1080p60_50Mb_h264 Overvie Video H264 1920x1080 60 Audio PCM 24b amp ch Disk size 1 04GB Show Playlist Standard interop Licenses Duration 00 02 30 Dd Network Streamer 1D um uvid dc01176d 88ba 4a4a 928c 861eb688t5ce Creation 2014 02 17717 49 59 08 00 Creator Doremi030612 Company Figure 25 Control Tab CPL Information 12 4 2 Deleting an Asset e To permanently remove a particular asset from the hard drive log into the LE100 Web GUI and go to the Control tab e Click on the Content Manager link and then the Composition Playlist link on the left side of the GUI see Figure 25 e Click on the row that contains the CPL name to select the CPL Then click the Delete button LE1 0M 002066 DRM Page 40 of 52 Version 1 1 Doremi Labs 12 5 Network Streamer The LE100 is capable of outputting a standard transport stream over the network The transport stream output from the LE100 will be the output of an incoming network signal or with a satellite receiver card installed LE100 SR
30. on 1 1
31. on 142 0 User Level root Administrator LOGOUT WW Figure 31 Software Version LE1 0M 002066 DRM Page 46 of 52 Version 1 1 Doremi Labs 16 Troubleshooting To troubleshoot the product all important product information is located on the Monitoring tab Here logs can be collected and stored in a compressed folder that can be sent to Doremi Labs Technical Support for review 16 1 Generating a Report via GUI e In order to generate a detailed report log into the LE100 Web GUI and go to the Monitoring tab e Click on the System link on the left side of the GUI see Figure 32 e Click on the Detailed Report button o It may take several minutes to generate the report The report will be saved to the client computer based on the web browser s download settings Detailed Report Button LE1 0 an Ga Serial Num er LE1 000001 root Administrator OVERVIEW ADMINISTRATION CONTROL MONITORING LOGOUT FP Detailed Report Chassis Networking Product name IP Address ethO 0 0 0 0 Serial number IP Address et 192 168 9 10 Base board Clock Versions System clock Thu Mar 06 2014 15 30 51 Firmware version Timezone America Los_Angeles Software version UTC Offset 430 minutes WebUl version Next DST change Sun Mar 9 01 59 59 2014 PST Booting Device Model USB EDC InnoDisk Capacity 3 83 GB Figure 32 Monitoring Diagnostics gure 3 onitoring agnost LE1 0M 002066 DRM Page 47 of 52 Version 1 1 Doremi Lab
32. p backward buttons to go forward or backward by 10 seconds The pause button can also be used to control playback e f playback of a live stream is paused the location bar can be selected and dragged to navigate to a specific part of the video and resume playback LE1 0M 002066 DRM Page 32 of 52 Version 1 1 Doremi Labs e Also while paused the current timecode field can be selected and a desired timecode can be entered to locate to Note In the Live mode the record buffer or the amount of video saved is only ten minutes The user will only be able to search and play back from the last ten minutes of incoming stream e Tocancel the live stream click the Eject button Note The stream will not be saved to disk when using the Live mode LE1 0M 002066 DRM Page 33 of 52 Version 1 1 Doremi Labs 12 1 2 Recording a Live Stream To record a live stream first make sure the recorder settings have been configured as described in Section 7 Click on the Record button and the Record Setup dialog window will appear see Figure 20 Screen 1e100 1 a 0 re Mm L El 0 0 Software Version 1 4 2 0 Serial Number LE1 000001 User Level root Administrator LOGOUT roy OVERVIEW ADMINISTRATION CONTROL MONITORING Editor e Source Network 10 netO Schedule Program 11001 No name KA Ingest Manager Video 1002 MPEG2 Video Audio 0 Custom PID GRHH Content Manager Dd Network Streamer Subtitles 0 Custom PID
33. port Controls Version 1 1 12 1 1 Playing a Live Stream e To play a live stream first make sure the recorder settings have been configured as described in Section 7 e Click on the Live button and the Live Setup dialog window will appear see Figure 19 a cree 1e100 1 L E 1 0 0 So Version 1 4 2 0 Serial Number LE1 000001 User Level root Administrator OVERVIEW ADMINISTRATION CONTROL MONITORING LOGOUT rey Ge r Live Setup Editor Live Stream E Select Source Network 10 netO Feeds Sche Schedule Program 1001 No name KA ingest Manager Video 1002 MPEG2 Video Content Manager Audio 0 Custom PID BEE Dd Network Streamer 0 Custom PID mode WEE 3D Side by Side 3D Top and Bottom Figure 19 Live Set Up e Choose the feed source Network or Satellite Note The satellite source is only displayed on LE100 SR or if the correct satellite board is properly installed e Select the appropriate Program Video Audio and Subtitle ID s from the incoming stream e If the stream is 2D leave the 3D mode set to auto detect If the stream is 3D select the appropriate 3D format e Click the Live button e The LE100 will recognize the live stream and begin playback after a few seconds o If the Playback window shows Waiting for Signal there may be a problem with the stream format or the network setup e While the live stream is playing the user can use the skip forward or ski
34. ps in the list e Use the Save button to name the playlist and save it for future use e The Open Button can be used to open previously saved playlists for playback at a later time e The Show Playlist can be played by switching to the CineLister Playback control and pressing the play button The playlist will be cued and played LE1 0M 002066 DRM Page 36 of 52 Version 1 1 Doremi Labs Refresh New Playlist Open Save Playlist Delete Elements List Playlist Playlist Properties Playlist LE100 De al Number LE1 001 root Administrator JERVIEW MINISTRATION SONTROL MO ORING LOGOUT 10 x Properties x Delete all elements SPL Show Playlist 2D Feature Bum_In_8CH_1080p60_50Mb_h264 Bum_in_8CH_1080p60_50Mb_h264 eg 2CH Bars Tone 720x480p_60_4x3_50Mb_h264 00 12 42 8CH Bars Tone 1080p_60_50Mb_h264 00 13 12 SCH Bars Tone 720x480p_60_4x3_50Mb_h264 LIVE 2D_61_20140305173009 00 13 42 Doremi_3D_FramePacking_SBS_1080p24_h264_50Mb Test 20H Bars Tone _720 480p EI Ae 50Mb_h264 00 14 12 Doremi_3D_FramePacking_SBS_1080p30_h264_50Mb 80H _Bars_Tone_1080p 60_60Mb_h264 00 14 42 Doremi 3D FramePacking SES 1080p50_h264_50Mb Start Time Elements Available Figure 22 CineLister Editor Playlist Clips Editor LE1 0M 002066 DRM Page 37 of 52 Version 1 1 Doremi Labs 12 2 3 Scheduling Playback e To schedule a playlist to begin playing at a specific date and time log into the LE100 Web GUI and go to the Control tab e Click on
35. s 16 2 Generating a Report via CLI To generate the report via CLI the operator has to log into the LE100 with administrator access and execute the following command Idoremi sbin report sh lt Enter gt The resulting file will be generated under the doremi tmp directory and the user will be able to use an FTP client to get it 16 3 Generating a Report via USB To generate a report using a USB key Create a directory doremi at the root of the USB key may have been previously created Create a directory report inside the doremi directory Safely remove the USB drive and plug it into the LE100 Wait two minutes without any USB activity watch your USB key LED Reboot the LE100 The report will be in the USB key folder doremi report LE1 0M 002066 DRM Page 48 of 52 Version 1 1 Doremi Labs 17 Hardware Specifications 17 1 Main Chassis e Internal SATA HDD e 2x 10 100 1000Base T Ethernet ports e 3x USB 2 0 ports 1 front 2 rear e 1x AC Power Connector e Embedded Linux Operating System 17 2 HD SD Decoding e MPEG2 up to 50Mbps e H 264 up to 50Mbps e VC1 up to 50Mbps 17 3 3D Support e 3D Decoding o SENSIO Hi Fi 3D format optional o RealD optional e 3D Output Formats o Side by Side o Top Bottom o Dual Stream o Frame Packing 17 4 Output Video Formats e 720p O 60fps 50fps 59 94fps e 1080i O 60fps 50fps 59 94fps e 1080p O 23 98fps 24fps 25fps 29 97fps 30fps 50fps
36. settings are not displayed if the correct satellite board is not properly installed e Go to the Administration tab click on the Control Panel link followed by the Input Feed Manager link e Under Input Configuration select sat0 0 or sat0 1 depending on which satellite input you wish to configure Note sat0 0 and sat0 1 are the default names for the satellite input ports These can be renamed as desired e Select the Modulation FEC Disceq Tone Inversion and Polarity to use Type in the proper Frequency and Symbol Rate values Then click on the Save button see Figure 11 e The new settings will be effective without rebooting e When the settings are entered correctly and there is a signal currently available the status section will show green for Enabled Signal Lock and Status The program list will also be displayed on the right hand side of the interface El S 1e100 1 LEI 00 e Version 1 4 2 0 Serial Number LE1 000036 vel root Administrator OVERVIEW ADMINISTRATION CONTROL MONITORING 10 Content Feed Manager e el Change the settings and click on Save button to save the configuration Satellite index 0 Enabled Output Configuration sat0 0 PSK_8 12106000 Control Panel 10750000 213 Port A oe 2398000 Program 32 MONTANA PBS MONTANA PBS or Video 101 H264 Video or Audio 256 MP2 Audio Subtitles Figure 11 Input Configuration Satellite LE1 0M 002066 DRM Page 23 of 52
37. t the desired language e Click the Login button when finished The user will be transferred to the Overview tab see Figure 6 Product Name Serial Number Logout Button User Level Software Version s l doremi LE1 00 e le100 1 on 140 0 Serial Number LE1 000017 root Administrator OVERVIEW ADMINISTRATION CONTROL MONITORING LOGOUT EI Current Live Recording Live Recording Storage Network Streamer Output Feeds a E net 9 data 775 GB free of 922 GB Figure 6 Overview Tab The Overview tab will provide information e g Product Name Serial Number User Level and Software Version as well as the current state of the LE100 see Figure 6 LE1 0M 002066 DRM Page 13 of 52 Version 1 1 Doremi Labs 4 2 Logging into the LE100 via SSH Connect the LE100 with an Ethernet cable to the client computer and power ON Install the program PuTTY or any similar SSH client on the client computer e Using the SSH client log into the unit with the LE100 s IP address on port 22 o The default IP address for Ethernet port 1 of the LE100 is 192 168 9 10 o Set your computer s IP address in the range 192 168 9 xx with xx being in the range 2 254 except 10 when using default IP Note If the IP address was changed use the IP address that was assigned to the LE100 instead of the default IP e Login as admin o Default password for admin 1234 Note The admin password can be changed in the web interface or b
38. the Administration tab and click on the System link on the left Then click on the Restart button see Figure 29 Shutdown Restart System Link Administration LE100 Serial Number LE1 000001 OVERVIEW ADMINISTRATION CONTROL MONITORING LOGOUT To restart the system click the Restart button You will be automatically disconnected from the web interface To shutdown the system click the shutdown button e Control Panel Figure 29 System Restart Shutdown g y Button Button LE1 0M 002066 DRM Page 44 of 52 Version 1 1 Doremi Labs 15 Updating the LE100 Software and Firmware Software and firmware updates for the LE100 can be performed using the web interface or by using FTP An FTP client e g Core FTP or Filezilla is needed to upgrade the LE100 via FTP WARNING Firmware updates can take approximately ten minutes to complete During the firmware update process the amber Activity LED on the front of the LE100 will remain illuminated Do not remove power or reset the unit during a firmware update Once the Activity LED turns off it is safe to log into the LE100 15 1 Software Update via Web GUI e Log into the LE100 Web GUI and go to the Control tab e Click on the Ingest Manager and then Upload link on the left side of the GUI see Figure 30 e Click on the Choose File button to browse to the update package pkg file and then click the Upload button e Onc
39. the CineLister link followed by the Schedule link on the left side of the GUI see Figure 23 e The first page shows existing schedules for the current week To view or create schedules for future weeks click on the Next Week arrow until the desired week is displayed e To create a new schedule select the New button To delete an existing schedule highlight the event in the list and click the Delete button New Delete Schedule Schedule Next Week LE100 a 1420 Serial Number LE1 0000 1 se toot Administrator O ERVIEW ADMINISTRATION CONTROL MONITORING New Delete Editor avhack Mon 03 Sun 09 March 2014 Playback Time Show Playlist Today Thursday 06 March 2014 5 46 15 58 Show Playlist 1 Sunday 09 March 2014 16 46 16 58 Show Playlist 1 Display out dated schedule Figure 23 CineLister Schedule 12 3 Ingest Manager The Ingest Manager is used to import DCP files as well as DLM license files that enable optional features e Toingest a DCP or DLM plug a properly formatted USB drive containing the files into one of the LE100 s three USB ports e Log into the LE100 Web GUI and go to the Control tab LE1 0M 002066 DRM Page 38 of 52 Version 1 1 Doremi Labs e Click on the Ingest Manager and then the Ingest Scan link on the left side of the GUI see Figure 24 e Using the Select Location pull down menu choose local storage All available local storage devices will automatically be scanned and
40. tor 1e100 1 L y 1420 E SIO Serial Number LE1 000001 Js root Administrator OVERVIEW ADMINIS ATION CONTROL MONITORING LOGOUT 0 x Properties x Delete all elements SPL Show Playlist 2D rem 00 00 00 Bum In_SCH_1000p60_SOMD has Bum_in_8CH_1080p60_50Mb_h264 Andrewt E Live 21 2CH Bars Tone_720x480p_60_4x3_50Mb_h264 Andrew S z 42 8CH_Bars_Tone_1080p_60_50Mb_h264 Live 12 SCH Bars Tone 720x480p_60_4x3_50Mb_h264 LIVE 2D_51_20140305173009 een Doremi_3D_FramePacking_SES_1080p24_h264_50Mb 20H Bars Tone 720x480p_60 4x3 50Mb_h264 12 Doremi_3D_FramePacking SBS_1080p30_h264_50Mb SCH Bars Tone 1080p 60 50Mb_h264 42 Doremi_3D_FramePacking SBS_1080p50_h264_50Mb 00 15 12 Doremi 30 FramePs Start Time Elements Figure 21 CineLister Editor 12 2 2 Creating a Playlist e To create a playlist containing multiple clips for playback log into the LE100 Web GUI and go to the Control tab e Click on the CineLister link followed by the Editor link on the left side of the GUI see Figure 22 e Selecting the New button will clear the Show Playlist and allow the user to start a new list e Single clicking on a clip in the All Available Elements column will add that clip to the Show Playlist column Repeat this procedure to add all of the desired clips to the Show Playlist o The up and down arrows at the right hand side of the Show Playlist window can be used to re arrange the cli
41. twork Configuration Save Button Reset Button e Go to the Administration tab click on the Control Panel link followed by the Networking Configuration link e Fill in the appropriate information for either Ethernet Port 0 or Ethernet Port 1 and click on the Save button The changes will take effect once the unit is rebooted see Figure 7 5 1 1 Adding or Removing NTP Servers e To add or remove NTP Servers click on the Administration tab select Control Panel and then under Time Settings select NTP Servers see Figure 8 LE1 0M 002066 DRM Page 16 of 52 Version 1 1 Doremi Labs a 1e100 1 LE100 on 142 Serial Number LE1 000001 root Administrator OVERVIEW ADMINISTRATION CONTROL MONITORING LOGOUT E Der pool ntp org Extra delay seconds Figure 8 NTP Servers e Click the Add button e Name the NTP server according to the desired format e Click the Save button to complete the configuration e f the user decides to cancel the NTP addition then click on the X next to the naming field see Figure 8 Note You must click on the Save button and reboot the unit for all changes to take effect e DNS can only be added using the USB or Command Line Interface CLI method LE1 0M 002066 DRM Page 17 of 52 Version 1 1 Doremi Labs 5 2 Network Configuration via CLI Note This method is valid for all LE100 software versions For more information on logging into the Command Line Interface CLI see Section 4 5
42. y using the following command and following the on screen instructions passwd LE1 0M 002066 DRM Page 14 of 52 Version 1 1 Doremi Labs 4 3 Logging into the LE100 via Serial Port e Connect the LE100 to a client computer via serial cable e Using HyperTerminal PuTTY or similar client log into the LE100 on the connected COM port o Serial connection settings are Speed 115200 Data bits 8 Stop bits 1 Parity None Flow control None Note The serial cable required for a proper connection is a straight through 1 to 1 serial cable not a null modem cable e Once connected log in as admin o Default password for admin is 1234 Note The admin password can be changed in the web interface or by using the following command and following the on screen instructions passwd LE1 0M 002066 DRM Page 15 of 52 Version 1 1 Doremi Labs 5 Network Configuration 5 1 Network Configuration via Web GUI e For more information on logging into the Web GUI see Section 4 Control Panel Administration LE100 m 1400 Serial Number LE1 000017 root Administrator OVERVIEW ADMINISTRATION CONTROL MONITORING LOGOUT Hostname le100 1 Properties of eth Properties of etiri E Term sal Ko Syst i e Control Panel Obtain an IP address automatically with DHCP Obtain an IP address automatically with DHCP IP address IP address 192 168 910 Netmask Netmask 255 255 255 0 Gateway Gateway ED EZE Figure 7 Ne