1. ACCON NetLink PRO compact 5 3 DEVICE DESCRIPTION E A amp R e Figure 1 ACCON NetLink PRO compact 1 2 3 4 5 6 RJ45 bushing to connect the device to the Ethernet Status LEDs for the Ethernet Interface Status LEDs Power supply bushing for 24 VDC Please keep the polarity in mind Bus plug with PG bushing Patch cable Cross Over 3 meters ACCON NetLink PRO compact Start of the ACCON NetLink PRO compact In the first seconds after starting the ACCON NetLink PRO compact the Power LED lights blue The start procedure will be finished after about 20 seconds then the device is ready to operate LED display POWER LED ACTIVE LED BUS LED Trying to log in on the ORANGE device at the bus BLINKING Device is logged in on BLUE GREEN the bus Data exchange with a BLUE GREEN controller Data BLINKING Table 1 Status LEDs tf POWER LED ACTIVE LED BUS LED Transmitting firmware BLUE RED update BLINKING BLINKING Table 2 Status LEDs Firmware Update i il LINK LED GRUN ACTIVE LED GELB connection Ethernet activity on BLINKING Table 3 Status LEDs Ethernet ACCON NetLink PRO compact 7 4 REQUIREMENTS FOR OPERATING Hardware Siemens S7 200 57 300 and 57 400 automation devices or compatible to S7 The utilized PCs must have a working network connection via TCP IP Also the network configuration must be known Usual network cards are suitable Software T
2. For a better overview the number of Number of Variables the desired variables can be selected between 1 and 10 No Continuous numeration The following items are supported AB Address Area AW AD EB EW ED MB MW MD DBB DBW DBD Counter and Timer Address of the bytes which want to be shown Data modules in the nomenclature Data module offset e g 108 10 Address Index The output value of a pressed button Result Value can be seen here Possible display modes are decimal Display Format hexadecimal or binary Free selectable description max 32 Desernipton characters To show the desired values the buttons 1x fetch for a refresh once or cyclic fetch for a permanent online request are available With Save Configuration the created mask including all set variables and their descriptions can be stored in the ACCON NetLink PRO compact The refresh rate is set to 0 5 seconds If several stations use this function from the TCP IP side then there is always only one connection resource reserved in the ACCON NetLink PRO compact During the additional data exchange via MPI PROFIBUS the Observe Variables function has the lowest priority Thus the refresh rate in the web interface is dependent from the parallel bus load ACCON NetLink PRO compact 43 10 REMOTE MAINTENANCE WITH THE ACCON NETLINK PRO COMPACT Ifthe ACCON NetLink PRO compact is used
3. Installation software After inserting the DELTALOGIC Automatisierungstechnik CD please start the data file SetupAcconS7Net exe for the ACCON S7 NET driver lt CD drive gt S7 Adapter For an installation you have to be logged in as administrator Set PG PC Interface 1 Open the SIMATIC PG PC interface The following points have to be in the dialog Set PG PC Interface ACCON S7 NET NLPro MPI ACCON S7 NET NLPro PPI ACCON S7 NET NLPro PROFIBUS ACCON NetLink PRO compact Set PG PC Interface CCON 57 NET NLPro MPI BBACCON S7 NET NLPro PPI 1 BBACCON S7 NET NLPIOPPROFIBUS Figure 2 Set PG PC Interface If not then click on the button Select to add remove interfaces Now you can see the window Install Remove Interfaces choose the module ACCON S7 NET NLPro and install the adapter 2 Click on the button Properties ACCON NetLink PRO compact 10 Properties ACCON S7 NET NLPro MPI a xl Bus parameter Local connection Options Stations NetLink PRO 192 168 3 801 Figure 3 A new created station 3 Click on New to create a station for the ACCON NetLink PRO compact By selecting a station it is set which ACCON NetLink PRO compact is assigned to the PG PC Interface But these stations will not be stored in the ACCON NetLink PRO compact aixi Address fi 92 168 3 124 Parametrize ACCON NetLink PRO P Internet teleservice Port p N
4. The ACCON NetLink PRO compact can be parametrized via a web interface too To do this open your web browser and enter the URL http 192 168 4 49 as long as you did not change the default address ACCON NetLink PRO compact 12 6 TCP IP PARAMETRIZATION There are two ways e Parametrization via Set PG PC Interface e Parametrization via the web interface of the ACCON NetLink PRO compact look for chapter 9 i The ACCON NetLink PRO compact will be shipped with the IP address 192 168 4 49 Setting TCP IP parameters To change the TCP IP parameters select the desired station and click on Edit The following window appears ES Address 192 168 3 124 Parametrize ACCON NetLink PRO P Internet teleservice Port f Name Myn ame OK Cancel Search ACCON NetLink PRO Help Figure 6 Set station Via Parametrize ACCON NetLink PRO compact you get to the input mask with the ACCON NetLink PRO compact s parameters ACCON NetLink PRO compact 13 ACCON NetLink PRO properties AE m IP address properties P GetIP address automatically DHCP DHCP Timeout s Static entries Current settings IP address 192 168 1 182 192168 1 182 Subnet mask 255 255 255 0 255 255 255 0 Gateway 192 168 1 1 192168 1 ACCON NetLink PRO properties Name NL Pro Labor 7 Web interface active Change password Save inACCONNetLink PRO Help Figure 7 Setti
5. 0200 fea 1 0 0240 1 0 1 10201 fe 2 1 0241 2 0 2 10202 I6 2 2 0242 3 0 3 0203 e7 2 3 0243 4 0 4 10204 les 1 4 0244 5 0 5 10205 e 1 5 0245 6 0 6 10206 In 2 6 0246 7 0 7 1020 In h 7 0247 8 0 8 lozo8 72 2 8 0248 9 0 9 10209 73 h 9 0249 10 bo 10 o20a 7a h 10 024A 11 bo 11 oe 7s h 11 0248 12 lo 12 o20c 7 2 12 Jo2ac 13 lo 13 0200 177 2 13 lo240 14 fo 14 o20E 178 2 14 024 15 0 15 o20F 79 2 15 o24F 16 lo 16 10210 fso h 16 _ 10250 17 bo 17 0211 ls 2 17 0251 18 lo 18 10212 h 18 0252 19 o 19 10213 183 1 19 _ 10253 20 lo 20 10214 s4 2 20 10254 ACCON NetLink PRO compact 54 mus Rack Slot TSAP Su Rack Slot TSAP 21 lo 21 10215 les 2 21 10255 2 lo 22 10216 fee 2 22 10256 23 lo 23 10217 ler h 23 0257 24 lo 24 0218 leg 2 24 10258 25 lo 25 10219 fse 2 25 0259 26 lo 26 loza 90 12 26 025A 27 lo 27 o21B lor 12 27 1025B 28 lo 28 lonc lo 2 28 lo25c 29 lo 29 loze loz 12 29 1025D 30 lo 30 o21F low 12 30 025 31 lo 31 10220 los 2 31 025F 32 a 0 o220 los 13 0 0260 3 1 loza 1970 bB 1 0261 34 li 2 10222 log 13 2 0262 35 1 3 o223 lo 13 3 0263 36 l 4 0224 100 13 4 0264 37 a 5 10225 101 13 5 0265 33 1 6 10226 102 13 6 0266 39 h 7 10227 1103 13 7 0267 so fa 8 o228 104 13 8 0268 an ft 9 0229 105 13 9 0269 42 a 10 o22a 1106 l 10 026A 3 1 11 1022B 1107 l 11 0268 44 a 12
6. 192 168 4 36 To deactivate it enter OFF TCP IP addresses which are not indicated here have only read access on the web interface and cannot change the configuration An access with ACCON S7 NET is limited too server in company networks to the list Otherwise a secure use of the O If you want to avoid unauthorized use you must not add possible proxy ACCON NetLink PRO compact is only limited To undo changes just press the Cancel button By clicking on Submit the entered values will be checked If there is a wrong input a possible solution is shown If all is correct all changes are shown again and with a click on Store the values will be stored in the ACCON NetLink PRO compact To activate the new configuration the ACCON NetLink PRO compact will be restarted after saving the new parameters If desired the ACCON NetLink PRO compact can be activated remotely via the configuration interface To do this click on Device Reboot It is possible to restore the ACCON NetLink PRO s default values via the button Restore Factory defaults All user defined settings will be deleted ACCON NetLink PRO compact 42 Observe Variables This function can only be used when the NetLink is Online and the RFC 1006 mode is used The activation is described in chapter 8 Parameters for monitoring variables With the help of the dropdown menu MPI Address an active MPI PROFIBUS address S7 CPU is selected
7. ACCON NetLink PRO compact 47 Q Sometimes MPI or PROFIBUS connections with high baud rates are getting disconnected although the ACCON NetLink PRO compact is put on the PLC and no other users are connected A Be sure that the bus is correctly terminated Even though the ACCON NetLink PRO compact is the only device connected to the bus in addition to the PLC You have to insert the final resistor Above all high baud rates can be interfered Q If set the ACCON NetLink PRO compact to autobaud in the PG PC interface and try to go online the active LED lights up briefly before a message appears telling me that the bus parameters cannot be determined A Please deactivate the autobaud function in the NETLink S7 NET driver PG PC interface and set the correct baud rate and the correct profile Q enabled the RFC function the web interface and would like the ACCON NetLink PRO compact to go on the bus using autobaud Unfortunately the active LED just flashes but no communication is possible via my visualization system A Please deactivate the autobaud function in the web interface of the ACCON NetLink PRO compact and set the correct baud rate with the corresponding bus parameters Q have read that the ACCON NetLink PRO compact can communicate with up to seven PCs at the same time But can t manage to query a status of my automation system from more than six PCs at once A A total of seven TCP connections are avai
8. 1022c 1108 13 12 0260 as 13 1022D 1109 l 13 _ 026D 46 1 14 loz uo l 14 026 47 15 loz hu b 15 _ 026F ACCON NetLink PRO compact mus Rack Slot TSAP Su Rack Slot TSAP 48 1 16 10230 1112 bB 16 0270 49 1 17 10231 1113 b 17 en so h 18 10232 14 b 18 _ 10272 51 1 19 10233 1115 b 19 _ 10273 2 a 20 10234 116 13 20 10274 53 lA 21 10235 jur 13 21 10275 s4 1 22 10236 118 13 22 10276 55 23 10237 119 13 23 0277 ss l 24 0238 120 13 24 10278 57 a 25 10239 121 13 25 10279 ss h 26 o23a 122 13 26 027A s9 h 27 lo238 123 13 27 1027B 6 l 28 o23c 124 13 28 027C a i 29 lo23D 125 13 29 027D 2 l 30 023E 126 l3 30 027 63 l 31 023F Table 5 Conversion table Updates on the Internet You can find the latest drivers and firmware versions on www deltalogic de in the download section ACCON NetLink PRO compact 56
9. Ed E Bus parameter Local connection Options r Station parameters IV Automatic reconnaissance of the net related parameters Address fo Timeout ms fi 0000 r Network parameters Transmission rate Highest Station Address l 31 v Abbrechen Hilfe Figure 8 Automatic reconnaissance of the net related parameters activated ACCON NetLink PRO compact 17 To ease the configuration it is possible to activate the function Automatic reconnaissance of the net related parameters Thus the ACCON NetLink PRO compact gets the bus parameters independently So the ACCON NetLink PRO compact can be used with different automation systems without changing the bus settings The automatic reconnaissance of the net related parameters cannot be used when the function Automatic reconnaissance of the net related parameters is not activated or not supported in the used PLC e g using 57 200 older Siemens S7 CPUs if the ACCON NetLink PRO compact is the only master at the bus When using the autobaud function the initialization lasts a bit longer because the online parameters have to be determined It is possible that the autobaud function does not work correctly at slower transmission rates e g 19 2 Kbps or with global data communication PROFIBUS communication The PROFIBUS configuration is the same as the MPI configuration Only the net related parameters are wider With
10. Security interface is activated Currently used TCP connections The amount of open TCP connections is shown here MPI PROFIBUS Settings Go Online after boot up Shows if the NetLink connects automatically with RFC1006 after it boots up or not ON or OFF If activated ON further parameters are visible ACCON NetLink PRO compact 35 The following parameters are only visible if Go online after boot up is activated Shows the own station address It is the address with which the ACCON NetLink PRO compact participates in the bus cycle Own station address If autobaud is OFF the stored bus parameters with which the ACCON NetLink PRO compact tries to go online are displayed here ON E Rack Slot Mode is active OFF E Addressed Mode is active If the Rack Slot Mode is activated all incoming RFC1006 queries are forwarded to the parametrized bus address If the ACCON NetLink PRO compact has Number of used RFC opened at least one TCP or RFC connections connection the amount of open RFC connections is shown here Stored bus parameters Rack Slot Mode Fixtarget address for Rack Slot Mode Additionally there are three Buttons on the website Diagnostic Page With this button you can get closer information about the communication of the NetLink Search Passive Stations With this button you can search passive Stati
11. compact 46 12 FREQUENTLY ASKED QUESTIONS Q I do not know my PC s IP address A Use the prompt and enter the command ipconfig to gain information about your Ethernet interface INNT system32 cmd exe pconfig Windows 2888 1P Konf iguration Ethernetadapter LAN Verbindung hes DNS Suffix deltalogic local e 192 168 3 16 Subnetzmaske Standardgateway Figure 25 ipconfig Q The configuration tool as well as the web interface asks for a password But did not enter any password A The ACCON NetLink PRO compact must have a password If no password is set the standard password is admin Q There are no dialog settings in the Simatic Manager A When you installed the ACCON S7 NET driver for the first time you have to add it to the PG PC interfaces too Make sure that you have administrator rights when installing the driver After a successful installation you have to reboot your system Simatic Manager Version 5 1 is minimum Q It is not possible to go online when the adapter is put on the PROFIBUS A If possible use the autobaud function If not desired or possible you have to check the Profibus timing parameters in the STEP7 project planning Via the Bus Parameters button you can enlist the read off values into the extended bus parameter settings You have to increase the TRT Target Rotation Time parameter in the ACCON NetLink PRO compact as well as on the PLC
12. for remote maintenance the administrators of both involved networks should be consulted Router PAT 222 111 1 1 1234 222 111 1 1 1235 192 168 1 81 7777 192 168 1 82 7777 esse fant 4 wese zm F intenst Femwartunc 1 F internet Feimwarlung ee fi e E flexible w per Name Figure 24 Example of an internet remote maintenance If more than one ACCON NetLink PRO compact is used behind a router you can activate Internet remote maintenance at the stations On this way each station gets its own port address Furthermore the router should support NAPT Network Address and Port Address Translation respectively PAT Port Address Translation ACCON NetLink PRO compact 44 11 TROUBLE SHOOTING Error Power LED does not light Cause ACCON NetLink PRO compact has no voltage supply The used MPI bushing has not the necessary 24 VDC Solution Plug MPI PROFIBUS cable on PLC interface Apply 24 VDC externally Active LED is blinking red ACCON NetLink PRO compact exception error on Ethernet side Plug MPI PROFIBUS cable again on the PLC interface Connect LED is blinking red ACCON NetLink PRO compact exception error on MPI PROFIBUS side Plug MPI PROFIBUS cable again on the PLC interface Link LED does not light No connection to Check Ethernet green the Ethernet connection Configuration of the ACCON NetLink PR
13. has logged in on the bus ACCON S7 NET NLPro MPI 21x Bus members Bus parameter Station type MLFB number D Station active Station address 2 Station active 6ES 417 4XL04 0480 Read V Read MLFB number Abbrechen Hilfe Figure 14 Diagnostics function Click on the button Read to determine the values Notes about the stations Address Bus address of the station Station type There are active Master and passive Slave stations MLFB number The order number of the station is only shown if the option Read MLFB numbers is activated The used ACCON NetLink PRO compact is shown as Station address Notes about the bus parameters ACCON NetLink PRO compact 23 Ifthere is no automatic reconnaissance of the net related parameters the manually set bus parameters of the ACCON NetLink PRO compact are shown ACCON NetLink PRO compact 24 8 COMMUNICATION VIA RFC1006 S7 TCP IP RFC1006 is an official standard and supported by many manufacturers Lots of manufacturers of visualizations are using this protocol to access S7 controllers via Siemens Ethernet CPs e g CP343 1 or CP443 1 The following software with RFC1006 support has been tested with the ACCON NetLink PRO compact e WinCC V6 0 Siemens AG e ZenOn V6 2 COPA DATA e PROCON Win V3 2 GTI Control e DELTALOGIC 57 S5 OPC Server from V3 1 DELTALOGIC GmbH e ACCON AGLink40 DELTALOGIC GmbH e NAT OPC Server I
14. parameters to assure that the ACCON NetLink PRO compact is available in the network and if necessary configurable Values smaller than 30 seconds will be replaced by the default value 30 seconds as most of the DHCP servers need between 12 and 20 seconds to assign valid parameters By clicking on the button Save in ACCON NetLink PRO compact the parameters will be permanently stored in the ACCON NetLink PRO compact If not the parameters will be deleted after the next reboot The used default values User name ACCON NetLink PRO compact Password admin If all entered correctly the following message appears Parameter in the ACCON NetLink PRO compact successfully written The reboot time depends on the DHCP It takes at most 20 seconds plus the set DHCP timeout Additional features In the input mask ACCON NetLink PRO compact properties there are more options e Name Here you can give the ACCON NetLink PRO compact a name for a better identification in the search window This name will be stored in the device A possible naming would be according to the location e g conveying machinery HG1 user name e g Mr Smith or something else e Change password Here you can set or change an already existing password When a password is set you can only change the ACCON NetLink ACCON NetLink PRO compact 15 PRO compact s configuration with it This is valid for both parametrization via driver and
15. 21 Driver options In the tab Options you can select the language of the dialogs and messages Furthermore the driver versions are displayed Properties ACCON S7 NET NLPro MPI 2 xj Bus parameter Local connection Options Language of the display elements C Use SIMATIC Manager setting C German English Versions File Version Accon57Net cnt 06 06 2007 02 50 00 AcconS 7Net dll 2 5 0 0 AcconS7NetA hip 06 06 2007 02 50 00 AcconS7NetB cnt 06 06 2007 02 50 00 AcconS7NetB dil 2 5 0 0 AcconS 7NelB hip 06 06 2007 02 50 00 AcconS7NetL4 dil 2 5 0 0 Accon57NetX dll 2 5 0 0 Abbrechen Hife Figure 13 Driver options Language of the display elements After switching the language you have to call the settings window again to accept the changes Version information The names and versions of all drivers are indicated here If problems occur you can quickly check if the correct versions are installed by indicating the driver data You will find the latest drivers and firmware versions on our web site at www deltalogic de in the Download section ACCON NetLink PRO compact 22 Diagnostics function You can find this function via Set PG PC Interface gt Diagnostics There you can execute hardware diagnostics of the module You can determine the following values 1 List of all reachable stations at the bus 2 The bus parameters with which the ACCON NetLink PRO compact
16. 7 d ce ACCON 7 ALT Mo ACCON NetLink PRO compact User Manual The Best Solutions for PLC This manual is for project developers users and assemblers who utilize the ACCON NetLink PRO compact It shows the user the handling of the ACCON NetLink PRO compact and explains signaling functions All necessary data for assembling should be provided to the assembler O 1995 2012 DELTALOGIC Automatisierungstechnik GmbH Stuttgarter Strasse 3 73525 Schwaebisch Gmuend Germany Phone sales 49 0 7171 916 120 Phone support 49 0 7171 916 112 Fax sales r 0 7171 916 220 Fax support 9 0 7171 916 212 E Mail sales sales deltalogic de E Mail support support deltalogic de www deltalogic de All rights reserved No part of this work is allowed to be copied reproduced conferred processed and stored into electronic media or translated into any other language without a written permission of the author S7 200 S7 300 S7 400 HMI STEP and SIMATICO are registered trademarks of Siemens AG ACCON and DELTALOGIC are registered trademarks of DELTALOGIC Automatisierungstechnik GmbH Note We have checked the content of this manual for conformity with the hardware and software described Nevertheless because deviations cannot be ruled out we cannot accept any liability for complete conformity The data in this manual have been checked regularly and any necessary corrections will be included in subsequent edi
17. C Gerat 6 Nicht aktiv 4 4 C Ger t Nicht aktiv C Gerat 8 Nicht aktiv C Gerat 9 Nicht aktiv C Gerat 10 Nicht aktiv C Ger t 11 Nicht aktiv C Ger t 12 Nicht aktiv C Ger t 13 Nicht aktiv C Gerat 14 Nicht aktiv C Ger t 15 niche aktiv ui 4 OK Abbrechen bernehmen Hilfe 510 Figure 16 Configuration example for RFC1006 This configuration can be used for the following software packages ACCON AGLink Version 3 x and 4 0 DELTALOGIC S7 S5 OPC Server SPS Analyzer AutoSPy ACCON S7 Power Tools ACCON S7 EasyLog Use of RFC1006 with WinCC v 6 0 To parametrize a RFC1006 connection in WinCC you have to create a new TCP IP connection in the SIMATIC S7 PROTOCOL SUITE The new connection is called NetLink_PRO here ACCON NetLink PRO compact 28 Figure 17 Create TCP IP connection Click on Read and you get to the following settings u Connection Parameter TCP IP Figure 18 Connection parameters TCP IP In this case the ACCON NetLink PRO compact has the IP address 192 168 4 38 The target CPU with which should be communicated has the PROFIBUS address 49 The addressed mode is used so the value for ACCON NetLink PRO compact 29 Rack and Slot can be checked up in the address conversion table in chapter 14 APPENDIX But the connection st
18. NAT GmbH e WinCE 5 0 Terminal TP21AS S tron Electronic GmbH e InTouch V9 5 Wonderware GmbH The communication with 57 200 controller over RFC1006 is not 1 supported Configuring the RFC1006 option RFC1006 can be used anytime In the web interface is an option Go online after boot up It can be used to automatically log in the ACCON NetLink PRO compact on bus after it boots up This option doesn t have to be activated to communicate with RFC1006 ACCON NetLink PRO compact 25 Addressed Mode RFC1006 Rack 1 Slot17 AG Nr 49 RFC1006 ISO on top of TCP IP f NETLink PRO TEW MPI PROFIBUS AG Nr 49 Figure 15 Addressed Mode With the addressed mode it is possible to access several CPUs which are at the same MPI PROFIBUS If this mode is used you have to configure the following in the web interface e Rack Slot Mode has to be off OFF e In the application s RFC1006 driver you have to indicate the bus address rack and slot number of the CPU which should be accessed Example If you want to communicate with the PLC number 2 Rack 0 Slot 2 If you want to communicate with the PLC number 49 E Rack 1 Slot 17 A conversion table for the rack and slot numbers is in the chapter Appendix Parametrization tools without a rack and slot fields mostly have a parametrization field for the Remote TSAP Normally this is 2 bytes long and is shown
19. O compact New password Password with a maximum of 8 digits Retype new password Repeat password with a maximum of 8 digits Entered changes can be undone with the button Cancel By clicking on Submit the entered values are checked If there is a wrong input a possible solution is shown If all is correct all changes are shown again and with a click on Store the values will be stored in the ACCON NetLink PRO compact To activate the new configuration the ACCON NetLink PRO compact will be restarted after saving the new parameters If desired the ACCON NetLink PRO compact can be activated remotely via the configuration interface To do this click on System Reset ACCON NetLink PRO compact 41 Security page The security page contains rudimental TCP security settings Before opening this page you have to enter the correct device name ACCON NetLink PRO compact and the password standard password is admin Via the button factory defaults the ACCON NetLink PRO compact can be set to ts standard settings The used standard values User name ACCON NetLink PRO compact Password admin If the TCP Access list is activated with ON only TCP connections to the ACCON NetLink PRO compact can be established which have been unlocked in the table TCP address 1 to TCP address 12 whitelist Enter an IP address which has to be unlocked according to the following example
20. O compact via ACCON S7 NET The message ACCON ACCON NetLink ACCON NetLink PRO NetLink PRO compact cannot be parametrized now appears PRO compact is active on the bus during parametrization compact has to be inactive during parametrization The message Wrong password appears Password incorrect and or parametrization time exceeded Setting TCP IP parameters Enter correct password and mind parametrization time No ACCON NetLink PRO compact is reachable via the entered IP address ACCON NetLink PRO compact is not online or still starting IP configuration of Activate ACCON NetLink PRO compact or complete starting procedure ACCON NetLink PRO compact 45 PC and ACCON NetLink PRO compact are not identical PC and ACCON NetLink PRO compact have to be in the same network segment ACCON NetLink PRO compact not reachable Ports have to be released in the firewall To search the ACCON NetLink PRO compact the UDP ports 25342 and 25343 have to be released For the communication the TCP port 7777 and 102 RFC1006 have to be released The program STARTER has problems when accessing a MICROMASTER or SINAMICS Failure and application monitoring too low 1 Increase the timeout in the PG PC Interface to 80000ms 2 Increase failure monitoring to 200ms and application monitoring to 5000ms ACCON NetLink PRO
21. OL SUITEITCP IP NetLink_PRON External Tags 1 License 128 Num 4 Figure 21 Connection NETLINK_PRO If this variable is now included in the initial screen of the WinCC project a connection will be established to the CPU with address 49 via the ACCON NetLink PRO compact to access marker byte 0 Further ACCON NetLink PRO compact 31 variables of different types can of course be created and used according to the same scheme It is also possible to create additional TCP IP connections in order to communicate with more CPUs Rack Slot Mode dl NETLink PRO mw MPI PROFIBUS Figure 22 Rack Slot Mode A special feature ofthe RFC1006 option is the Rack Slot mode Using this function it is possible to access several CPUs which are on the same Rack Multicomputing via one bus address A connection from a PROFIBUS CP z B CP342 5 to a S7 CPU is possible too Only to the set station PLC number will be communicated to This station forwards the data packages to the desired Rack Slot To use this function the following settings on the configuration page of the web interface have to be made e Rack Slot mode ON e At Fix destination address for R S mode the address PLC number of the desired communication partner has to be entered In this example 49 ACCON NetLink PRO compact 32 9 THE WEB INTERFACE The web interface of the ACCON NetLink PRO compact can be used w
22. PROFIBUS the additional settings for bus profile and bus parameters are available Properties ACCON S7 NET NLPro PROFIBUS _ EE Bus parameter Local connection Options r Station parameters M Automatic reconnaissance of the net related parameters Address 0 Timeout ms 10000 r Network parameters Transmission rate 187 5 Kbps y Highest Station Address 126 x Profile DP i Bus parameters Abbrechen Hilfe Figure 9 Automatic reconnaissance of the net related parameters deactivated ACCON NetLink PRO compact 18 Profile Using PROFIBUS the following profiles DP Standard and User defined can be used You have to select the profile which is already set in the automation system Bus parameters Unlike to MPI the bus parameters under PROFIBUS are not constant and change in relation to the number and type of the used PROFIBUS stations You should always use the PROFIBUS parameters which are set in the actual automation system look for it in the STEP7 project Tslot 300 tBit Max Tsdr 150 tBit Min Tsdr I 11 Bit Tset I 1 tBit Taqui ot Gap factor _ 10 Retry limit a Ttr 27955 Bit Cancel Help Figure 10 Extended bus parameter settings To sidestep these partly complex steps you can use the function Automatic reconnaissance of the net related parameters under PROFIBUS To get the Automatic reconnaissance of the net related para
23. a taken from the parametrizati master normally the CPU ue has to be on of the bus Tqui Using MPI this value is always 0 With PROFIBUS the respective va taken from the parametrizat master normally the CPU ue has to be ion of the bus Gap Using MPI this value is always 5 With PROFIBUS the respective va taken from the parametrizat master normally the CPU ue has to be ion of the bus Retry Using MPI this value is always 2 With PROFIBUS the respective va taken from the parametrizat master normally the CPU ue has to be ion of the bus Please keep in mind that a wrong parametrized ACCON NetLink PRO compact can interfere with the bus so that a regular operating is not possible any more Due to this reason the autobaud function is very handy Thus the correct parameters are used automatically But the CPU must support this function A Wrong bus parameters can interfere with the bus ACCON NetLink PRO compact 40 Rack Slot Mode or ON Rack Slot Mode is active Routing over RFC OFF E Addressed M ode is active ON OFF Fix destination address for R S mode If the Rack Slot Mode is activated all or incoming RFC1006 queries are forwarded Station address of to the parametrized bus address routing gateway User Password Settings User Here you can set a Username Default ACCON NetLink PR
24. ame IM lyName K Cancel Search ACCON NetLink PRO Help Figure 4 Set a station 4 Click on Search ACCON NetLink PRO compact in the Station dialog The following window appears ACCON NetLink PRO compact 11 Connected ACCON NetLink PRO in local network Ax IP address Serial number 00 06 71 19 04 FD T00001277 Close Get New search Properties Help Figure 5 List of all connected ACCON NetLink PRO compact devices 6 Mark the ACCON NetLink PRO compact and click on Close Get If the list is empty please read the chapter Trouble shooting 7 The window Station appears again Click on OK The driver settings are completed now 8 Close the window Properties ACCON S7 NET NLPro MPl by a click on OK 9 Close the window Set PG PC Interface by a click on OK 10 When an access path is changed in this settings a warning appears Confirm with OK when you want to accept the changes The ACCON NetLink PRO compact is shipped with the IP address 192 168 4 49 The ACCON NetLink PRO compact s IP address must fit into your network i For this the first three places ofthe IP address ofthe PC andthe ACCON NetLink PRO compact have to be equal e g PC IP address 192 168 4 10 ACCON NetLink PRO compact IP address 192 168 4 49 only valid if subnet mask 255 255 255 0 is used For more information please go to chapter 7 TCP IP Parametrization
25. d and changed via its integrated web site For security reasons the access to the web site is protected by a password The ACCON NetLink PRO compact supports the S7 communication via RFC1006 ISO on TCP Thus TCP IP communication processors e g CP343 1 can be replaced by this adapter But projected connections are not supported Furthermore the ACCON NetLink PRO compact supports the parametrization of DP Slaves via DP V1 Class 2 A driver for SIMATIC applications ACCON S7 NET is included in delivery The ACCON NetLink PRO compact is fed via the bus connection Alternatively the device can be externally supplied via 24 VDC The ACCON NetLink PRO compact can be connected to the PC via a hub or switch or directly with the supplied patch cable Cross Link ACCON NetLink PRO compact 3 Features Automatic bus profile detection Full PROFIBUS speed up to 12 Mbps Extended diagnostics Support of MPI PROFIBUS and PPI Supports DHCP Support of Slave programming via DP V1 Class 2 Supports all established SIMATIC Engineering Tools Supports ISO on TCP RFC 1006 Voltage feed from the PLC or controller External 24 V power supply possible Plug with PG bushing Applicable up to 60 C ACCON NetLink PRO compact 2 SCOPE OF DELIVERY e ACCON NetLink PRO compact e Patch cable Cross Over 3 meters e DELTALOGIC Automatisierungstechnik CD including ACCON S7 NET Driver Suitable accessories can be found on www deltalogic de
26. ent from each other e g if the baudrate is changed then all other parameters are changed too With MPI all parameters are given except the baudrate If a MPI connection is changed from 187 5 Kbps to e g 12000 Kbps all other parameters are unmodified Bus Profile MPI or DP Enter desired baudrate in Kbps Possible Baud rate values are 9 6 19 2 45 45 93 75 187 5 500 1500 3000 6000 and 12000 The highest station address is entered here With MPI normally 31 and with PROFIBUS HSA 126 Values which are not equal to the default values can be used All stations have to be adjusted equally Using MPI this value is always 415 With PROFIBUS the respective value has to be taken from the parametrization of the bus master normally the CPU Tslot_Init Using MPI this value is always 9984 With PROFIBUS the respective value has to be taken from the parametrization of the bus master normally the CPU Ttr ACCON NetLink PRO compact 39 Max Tsdr Using MPI this value is always 400 With PROFIBUS the respective va taken from the parametrizati master normally the CPU ue has to be on of the bus Min Tsdr Using MPI this value is always 20 With PROFIBUS the respective va taken from the parametrizati master normally the CPU ue has to be on of the bus Tset Using MPI this value is always 12 With PROFIBUS the respective v
27. ill needs a variable To do so open the context menu of the connection with a right mouse click and choose New tag Tag properties MBO_over_NETLINK_PRO Unsigned 8 bit value ByteT oUnsignedByte fe Projectwide update a Figure 19 Tag properties In the Tag properties window you can choose the type of the variable MBO_over_NetLink_PRO here via the button Select ACCON NetLink PRO compact 30 Address properties Ext Address Description wo up Data Address Byte y MB fo Lenath fi F Quality Code Select the data area Figure 20 Flag byte 0 is going to be projected In the following screenshot you can see that there is now a new variable called MBO_over_NETLink_PRO under the point NetLink_PRO WinCCExplorer C TEMP schaumrmol schaumrmol McP 10 x File Edit View Tools Help Dae me gt e gt B schaumrmol Computer FEYMBO_over_NETLI Unsigned 8 bit value MBO 9 16 2008 1 05 20 PM ES Tag Management E Internal tags E f simatic 57 PROTOCOL SUITE Industrial Ethernet Industrial Ethernet IT MPI Named Connections PROFIBUS PROFIBUS II Slot PLC Soft PLC FEB 0 48 r Graphics Designer Alarm Logging ud Tag Logging Report Designer tas Global Script Text Library User Administrator Cross Reference Load Anina hannar schaumrmol Tag Management SIMATIC 57 PROTOC
28. in hexadecimal The field where only 1 byte is used can be parametrized as follows ACCON NetLink PRO compact 26 If you want to communicate with the PLC number 2 Remote TSAP 0202 If you want to communicate with the PLC number 49 E Remote TSAP 0231 There is a conversion table for the Remote TSAP values in chapter Appendix You can also use the formula Rack 32 Slot Address Configuration example of RFC1006 with STEP7 NetPro In the Network Configuration of STEP7 NetPro you can build a virtual S7 PLC as an ACCON NetLink PRO compact On this way you can connect a S7 PLC on MPI or PROFIBUS via Routing For this the virtual S7 PLC have to be configured with the IP address and the Bus address of the NetLink Don t forget to set S7Online STEP7 TCP IP in the PG PC Interface Ethernet 1 Industrial Ethernet MPI 1 MPI NetLink PRO CPU IMPIZDP PN I0 416 3 i PN DP 10 It also can be implemented in the TIA Portal PLC_1 Netlink_Pro CPU 317 2 DP CPU 319 3 PN DP PROFIBUS_1 ACCON NetLink PRO compact 27 Configuration example of RFC1006 with ACCON AGLink cg Ger te rest Optionen Programm Foto ror El TCP IP Einstellungen C Ger t chen m AG Nr IP Adresse Rack stot s7 2o0 C Gerat2 nicht aktiv q 192 168 4 49 o 1 C C Ger t3 iae 2 192 168 4 49 2 17 C Gerat 4 nicht aktiv C Gerat 5 Nicht aktiv
29. isting Connection Resources under object properties of the PLC in the hardware configuration ACCON NetLink PRO compact 49 13 TECHNICAL DATA Supported operating systems No restrictions the driver for SIMATIC ACCON S7 NET is only compatible with Windows 2000 XP 2003 Vista 7 2008 Ethernet interface and TCP IP Hardware requirements protocol Supported PLCs S7 200 S7 300 57 400 Default IP 192 168 4 49 a TCP 7777 TCP 102 RFC1006 port addresses NetLink Broadcast to UDP 25342 UDP Search 25343 Weight in kg ca 0 25 Dimensions W x H x D in nm 54x 105 x 30 Protection type IP 20 Voltage supply 24 VDC 25 External voltage supply possible Power consumption Max 150 mA Galvanically separated Yes Operating temperature 0 C to 60 C Temperature storage Erw o transport ER 0 0 o Relative humidity ie en Patch cable Ethernet straight 3m Yes Connection cable to the PC Supported bus profiles MPI DP standard Universal DP FMS user defined with automatic detection PPI ACCON NetLink PRO compact Supported transmission rate of 9 6 Kbps to 12 Mbps with the bus connection to the PLC automatic detection Supported transmission rates 10 100 Mbps with automatic Ethernet detection Max number of connections to 16 TCP IP Max number of connections to 32 MPI PROFIBUS PPI Supported software ACCON S7 EasyLog ACCON AGLink DELTALOGIC 57 S5 OPC Server W
30. ith any standard browser e g Internet Explorer Mozilla Firefox Opera etc Start page The welcome page of the ACCON NetLink PRO compact is called with ahttp ip address Default IP address 192 168 4 49 The web interface can activated deactivated via the configuration in the Q PG PC interface Via the welcome page you get to the following pages e Welcome page e Configuration page e Page for security settings e Page to monitor variables e Website of the DELTALOGIC Automatisierungstechnik GmbH Status page The status page shows the currently used settings of the ACCON NetLink PRO compact You cannot change anything there This page provides the following information Device specific parameters Product name ACCON NetLink PRO compact Order number 161701 PRO Firmware name ACCON NetLink PRO compact Firmware version e g V2 30 Bios version e g V2 30 Serial number e g T00006262 MAC address e g 00 06 71 19 00 3E ACCON NetLink PRO compact 33 Device name The name which was stored in the ACCON NetLink PRO compact is shown here MPI PPI PROFIBUS status Device is not online If the ACCON NetLink PRO compact is not connected to a PLC these words will be shown red Currently used connections The number of used bus connections is shown here These Parameters are only shown if a connection to a PLC is establi
31. ith the driver for SIMATIC ACCON S7 NET the following software can be used SIMATIC Manager from V5 3 WinCC 6 0 WinCC flexible ProTool STEP7 Micro WIN Table 4 Technical data Pin assignment Assignment MPI PROFIBUS interface En En 5 DGND Ground for bus termination looped through DVCC 5 VDC for bus termination looped through 24 VDC power supply looped through EN RxD TxD N Received transmission data N rete ACCON NetLink PRO compact 51 ACCON NetLink PRO compact 52 Assignment Ethernet interface Host Interface CCOO ECO CESTA en CAI BI nn nn rn The ACCON NetLink PRO compact is supplied with a 3 meter patch cable Cross Over category 5 The maximum length between two TCP IP interfaces must not exceed 100 meter according to IEEE802 Ifthere are distances greater than 100 meters you have to use repeater or switches Voltage bushing When using an external voltage feed you have to mind the correct polarity and the voltage ACCON NetLink PRO compact 53 14 APPENDIX Address conversion table The following table serves as a parametrization help for the addressed mode The bus address can be converted to Rack Slot or TSAP e g the controller with the bus address 49 is addressed by Rack 1 and Slot 17 or with the TSAP 0231 a Rack Slot TSAP oe Rack Slot TSAP 0 0 o
32. lable that can be used at the same time However please note that only up to six connections can be used at once per type of connection NETLink S7 NET or RFC1006 connections are possible The purpose of this is to keep one connection channel free for the other protocol in each case Q am using the rack slot mode of the RFC1006 interface and have specified address 2 for my existing PLC in the web interface in Fix destination address for R S mode Although the ACCON NetLink PRO compact online is active active LED lights up my visualization system tells me that no connection can be established A Make sure you have assigned the correct values to rack and slot in the parametrization Look for chapter 8 ACCON NetLink PRO compact 48 Q would like to use addressed mode of the RFC1006 interface rack slot mode OFF so can access several PLCs on the same bus Unfortunately am not sure how to parameterize the fields rack and slot in the visualization used A If addressed mode is used a combination of rack and slot specifies the destination address of the automation system Q If mix RFC1006 connections and connections via the STEP7 driver the connection sometimes breaks off or error messages appear saying that itis not possible to establish a connection A For communication with 57 300 modules it may be necessary to parameterize the communication resources The user can influence the allocation of ex
33. meters to work you have to activate Cyclic distribution of the bus parameters in the hardware parametrization of the interface The following screenshot shows the switch for the Cyclic distribution of the bus parameters It is located in the hardware configuration of any PROFIBUS interface ACCON NetLink PRO compact 19 PROFIBUS 1 V Figure 11 Automatic reconnaissance of the net related parameters ACCON NetLink PRO compact 20 PPI communication The PPI configuration is the same as the MPI configuration but the automatic reconnaissance of the net related parameters is not possible with 57 200 controllers The PPI communication is supported not until version 2 5 of the ACCON S7 NET drivers At least firmware version 1 40 is needed Properties ACCON S7 NET NLPro PPI Ax Bus parameter Local connection Options r Station parameters M Automatic reconnaissance of the net related parameters Address fo Timeout ms fi 0000 m Network parameters Transmission rate 187 5 Kbps y Highest Station Address 31 Abbrechen Hilfe Figure 12 Bus settings PPI For more information of the use of Advanced PPI look for the help of the 57 200 programming software To communicate with a EM 277 you have to activate Advanced PPI Latest driver and firmware versions can be found on our web site in the Download section ACCON NetLink PRO compact
34. ngs of the ACCON NetLink PRO compact Static TCP IP configuration If the ACCON NetLink PRO compact is used in a network without a DHCP server or if the ACCON NetLink PRO compact should always work with the same IP address despite an existing DHCP server you have to enter the desired IP address into the input mask for Static entries In this case you must not set the function Get IP address automatically DHCP The ACCON NetLink PRO compact s IP address must fit into your network For this the first three places of the IP address of the PC and the ACCON NetLink PRO compact have to be equal e g PC IP address 192 168 4 10 ACCON NetLink PRO compact IP address 192 168 4 49 only valid if subnet mask 255 255 255 0 is used Use of DHCP Dynamic Host Configuration Protocol The problem with DHCP is that after every switch on the parametrized ACCON NetLink PRO compact can get another IP address The system administrator responsible for the DHCP server can prevent it The ACCON NetLink PRO compact s MAC address must have a permanent IP address at the DHCP server ACCON NetLink PRO compact 14 Ifthe ACCON NetLink PRO compact should get the IP address via DHCP automatically you have to set the function Get IP address automatically DHCP Additionally the field DHCP Timeout in s will be activated If the ACCON NetLink PRO compact does not get any parameters from a DHCP server within the time set the device uses the static
35. o use the ACCON S7 NET drivers you need a PC including Windows 2000 XP 2003 Vista Windows 7 or 2008 On this PC the SIMATIC Device Drivers PG PC Interface have to be installed The SIMATIC Device Drivers will be installed with e g STEP 7 STEP 7 lite or STEP 7 Micro Win By installing ACCON S7 NET more interfaces will be added to the PG PC Interface Take care of your Firewall Settings The ACCON NetLink PRO compact uses the TCP ports 7777 and 102 RFC1006 The Device Search function uses the UDP ports 25342 and 25343 The default IP address of the ACCON NetLink PRO compact is 192 168 4 49 Assembly Installation and assembly have to be carried out according to VDE 0100 IEC 364 As the ACCON NetLink PRO compact is an IP30 module it has to be built into a switch cabinet For secure operating please keep the maximum ambient temperature of 60 C in mind ACCON NetLink PRO compact 8 5 COMMISSIONING The ACCON NetLink PRO compact is shipped with the IP address 192 168 4 49 Connection to the automation device Connect the 9 pin SUB D plug to the MPI or PROFIBUS interface of your S7 controller Connection to the PC via RJ45 Ethernet Interface Put one end of the patch cable into the Ethernet bushing of your ACCON NetLink PRO and the other end into a hub or switch which is connected to your PC s network card You can also directly connect the ACCON NetLink PRO compact to your PC s network card without a switch
36. ons e g 57 200 IM151 7 DP Slaves The slave addresses will be shown on the website at the List of passive stations Go Online Offline With this button you can manually go online or offline with the ACCON NetLink PRO compact ACCON NetLink PRO compact 36 Configuration page The ACCON NetLink PRO compact can be configured via this page Before opening this page you have to enter the correct device name ACCON NetLink PRO compact and the password default password is admin Verbindung zu 192 168 1 72 herstellen Ax ACCON NetLink PRO compact Benutzername ACCON NetLink PRO compact y Kennwort eones P Kennwort speichern Abbrechen Figure 23 User name and password The user name and the password are case sensitive The used standard values User name ACCON NetLink PRO compact 1 Password admin ACCON NetLink PRO compact 37 After a successful authentication you have writing access on all parameters which are configurable via the driver interface of the ACCON S7 NET driver Device specific parameters Device name Name of the NetLink max 20 characters TCP Parameters Static IP address Used IP address if DHCP is deactivated or DHCP timeout elapsed Static subnet mask Used subnet mask if DHCP is deactivated or DHCP timeout elapsed Static gateway Used gateway if DHCP is deactivated or DHCP timeout elapsed In addition to the standa
37. rd port you can store a further user definable port forthe ACCON Additional NetLink or NetLink PRO compact DHCP ON OFF DHCP status DHCP timeout 30 to 65500 seconds Web interface ON OFF Web interface active or not MPI PROFIBUS settings If this option is ON the NetLink automatically tries to log in on the bus after it boots up Go Online after boot up ON OFF The following Parameters are only shown if Go online after boot up is activated Own station address The option Own station address shows with which bus address the ACCON NetLink PRO compact has logged in on the bus ACCON NetLink PRO compact 38 The value for the station address can be in the range of 0 including 126 But the chosen address must not be higher than the HSA highest station address and is not assigned to another device at the same bus Single Master ON OFF Using the option Bus autobaud ON OFF you can set if the ACCON NetLink PRO compact searches the bus parameters and goes online then or the device uses the stored bus parameters when going on the bus ON or OFF is possible Single Master bus parameters If the option Single Master ON OFF is activated ON you have to fill in the parameter fields belonging to the subitem Single Master bus parameters correctly When parametrizing you have to keep in mind that with PROFIBUS all parameters are depend
38. shed Own station address If the ACCON NetLink PRO compact is active on the bus you have to enter the bus address here Online Bus parameters If the ACCON NetLink PRO compact is active on the bus the itemized bus parameter set is shown here List of active stations If the ACCON NetLink PRO compact is active on the bus the list of active stations is output here The own address is displayed in red List of passive stations If the ACCON NetLink PRO compact is active on the bus the list of passive stations is output here ACCON NetLink PRO compact 34 TCP IP status IP address Current IP address of the ACCON NetLink PRO compact e 9 192 168 4 54 Subnet mask Current subnet mask of the ACCON NetLink PRO compact e g 255 255 255 0 Gateway Current standard gateway ofthe ACCON NetLink PRO compact e g 192 168 4 33 Listen on port The TCP port on which the ACCON NetLink PRO compact can be reached The default port is 7777 DHCP Shows if DHCP is activated or not If DHCP is ON there is the additional information if DHCP was successful or if the parametrized default IP address is used DHCP timeout Shows the DHCP timeout in seconds Configured via DHCP Shows if the IP address is given from a DHCP Server Connected to client address IP address which is connected to the NetLink Security interface ON OFF Shows if the
39. tions We always welcome suggestions for improvement Last update 2012 05 07 All technical changes reserved ACCON NetLink PRO compact 1 TABLE OF CONTENTS 1 TECHNICAL DESCRIPTION aavavav vv vv 3 2 SCOPE OF DELIVERY ssis 5 3 DEVICE DESCRIPTION v v 6 4 REQUIREMENTS FOR OPERATING uses 8 5 COMMISSIONING vszeouuuununnunnununnunuununnununnunnununnunnnnnnnnnn 9 6 TCP IP PARAMETRIZATION uses 13 7 BUS SETTINGS sssini 17 8 COMMUNICATION VIA RFC1006 S7 TCP IP 25 9 THE WEB INTERFACE aaa 33 10 REMOTE MAINTENANCE WITH THE ACCON NETLINK PRO COMPACT zuzanzonnnnnnnnnnnnnnnnnnnnnnnnnanns 44 11 TROUBLE SHOOTING ursnronnonnnnnnnnnnunnnnnnnnnnnnnnnnnnans 45 12 FREQUENTLY ASKED QUESTIONS sssrin 47 13 TECHNICAL DATA sssini 50 14 APPENDIX vvv1vvvv1 mmm m m mmmm HHHH 54 ACCON NetLink PRO compact 2 1 TECHNICAL DESCRIPTION ACCON NetLink PRO compact is a handy communication and programming adaptor between PC and S7 controllers The electronics of the ACCON NetLink PRO compact is placed in a PROFIBUS plug s case Thus the adapter is very small and handy As all rounder the ACCON NetLink PRO compact can be connected to the PLC via MPI PROFIBUS and PPI The ACCON NetLink PRO compact independently detects the current bus settings of the PLC The ACCON NetLink PRO compact s communication to the PC is carried out via TCP IP The configuration of the ACCON NetLink PRO compact can be create
40. web interface e Web interface active If activated and the password is known the parametrization of the ACCON NetLink PRO compact can be shown and changed with any standard browser e g Internet Explorer Firefox Opera For more information please go to chapter 9 By clicking the button Save in ACCON NetLink PRO compacta all parameters will be stored in the ACCON NetLink PRO compact ACCON NetLink PRO compact 16 7 BUS SETTINGS The ACCON NetLink PRO compact can be used with three different bus systems PPI MPI and PROFIBUS Configuration example MPI The most important setting in connection with the bus configuration is the station address This is the address which has the ACCON NetLink PRO compact on the bus when going online The station address can be in the range from 0 to 12 as long as the chosen address is smaller or equal as the highest station address This address is allowed only once The timeout can be set in the station related settings of the ACCON S7 NET driver If there is no response to a driver enquiry within the set timeout a communication error is sent to the SIMATIC application The decrease of the timeout has no effect on the transmission time and data throughput 10000ms is the recommended timeout value In the net related settings you have to adjust the transmission rate as well as the HSA of the automation system to which should communicated Properties ACCON S7 NET NLPro MPI