1. 2 Set up Mode Table MENU DISPLAY DESCRIPTIONS bon You can hear buzzer Buzzer boFF You cannot hear buzzer Pr oFF Do not use printer Printer Pr DLP 50 printer interface Label Pr DEP DEPSO printer interface Ticket Pr key Manual print DLP DEP Print method Pr AUt Auto print when the scale is stable DLP DEP Pr Str Ptint continually when the scale is stable DEP Linefeed p DEPonly LF1 LF9 Linefeed Barcode di gt DLP only BC on off Print out barcode on off pr 96 9 600 bps Baud Rate br192 19 200 bps br 384 38 400 bps bLon Use back light bL10 Back light is on 10 seconds Backlight bL30 Back light is on 30 seconds bL OFF Do not use back light Brightness Taz You can set backlight brightness Default 3 APoFF Do not use Auto Power Off function a Power turns to be off automatically when the scale is AP 10 E not in operation over for 10 minutes Aito Pu gt 30 Power tums to be off automatically when the scale is not in operation over for 30 minutes Power tums to be off automatically when the scale is AP 60 not in operation over for 60 minutes WL MO HIGH Limit gt Weight gt LOW Limit You will hear buzzer HIGH Limit s Weight Weight lt LOW Limit WL M1
2. Weight Limit You will hear buzzer WLM2 Weight lt LOW Limit You will hear buzzer WLM3 HIGH Limit lt Weight You will hear buzzer 4 P HIGH Limit gt Counting result gt LOW Limit CLMO You will hear buzzer 4 5 HIGH Limit s Counting result Count Limit CLM1 counting result lt LOW Limit You will hear buzzer CLM2 Counting result lt LOW Limit You will hear buzzer CLM3 HIGH Limit lt Counting result You will hear buzzer dyon Print out date day Date dy oFF Do not print out date day yymmad Declared date is Year Month Day Date Display dy on only ddmmyy Declared date is Day Month Year mmddyy Declared date is Month Day Year tion Print out time Time tioFF Do not print out time LAoff Do not print out label caption Label LAon Print out label caption dFOFF Default setting is released Default 0 Everything is setup in default X Italic Bold Default Setting 3 Select the DEP printer in the Set up mode LINE Feed Features are enable to use and if DLP printer is selected then Barcode features are enable to use However both Line Feed and Barcode features could not use at the same time 3 How to Enter Date dY on d on d of F iid i 1 Press the MODE key until the 2 If you do not want to print out date press the HOLD A key display shows d
3. Time gt means that you cancel the weight right before this weight Cumulative weight sum Aggregate times To operate the total print functions get into set mode and use print key to set up Sample format DLP 50 1 Weight tare Date 2888 89 24 15 88 88 Net 1234567 kg Tare 1234567 kg Gross 1234567 kg K In order to use the above label format Barcode set as OFF and weight comparison function as OFF in SET OP MODE 2 Weight Tare Barcode Date 2088 09 24 16 89 19 86008 1234565 234567 kg Tare 1234567 kg 1234567 kg 5 In order to use the above label format Barcode set as ON and weight comparison function as OFF in SET OP MODE 3 counting function unting Functi 1 5 elo ht 8 546 kg Quant ted 28 pcs COUNT LIMIT SET VALUE Limit H 0 200 pcs Limit L 6 100 pcs X Quantity Comparison Functions should set as ON 4 Weight comparison function oe Function EIGH 20088 09 aa 15 24 38 Weight 1234567 Kg WEIGHT LIMIT SET VALUE Limit H 1234567 kg Limit L 1234567 kg Weight comparison functions should set as ON When using DLP printer it could not print in the percentage mode 8 2 Auto Print To use auto print function you have to set printer menu to Pr AU in setup mode Refer to Setup Mode Table on page 19 2 Ifthe weight is stable it is printed out automatically And Y
4. 0 2009 08
5. HIGH 00090 or LOW 00100 HIGH 00100 9 Press the MODE key to go to weighing mode 40 Suppose that the High limit of 200 and the Low limit of 80 are set up In this condition A lamp is lighted on ifthe weight is 120 E lamp is lighted on if the weight is 220 and if the weight is 60 LO lamp is lighted on It beeps as fixed on User Setup Mode Refer to Setup Mode Table on page 17 8 Print Out 8 1 Manual Print You can print out data every time pressing the PRINT key You can setup print function depends on your need Refer to Setup Mode Table on page 19 Sample format DEP 50 Weighing Function DATE 2008 10 21 TIME 17 35 58 Weight 0 000 kg WEIGHT LIMIT SET VALUE Limit H 40 000 kg Limit L 30 000 kg Counting Function COUNT WELCOME TO CAS DATE 2008 10 21 TIME 17 35 58 Weight 40 200 kg Quantity 50 pcs COUNT LIMIT SET VALUE Limit H 2000 pcs Limit L 1000 pcs When the weight comparison function is set Cumulative Weight Sum Function DEPonly WEIGHT WELCOME TO CAS DATE 2008 10 21 TIME 17 35 58 Weight 4 180 kg Weight 4 200 kg Weight 4 200 kg Weight 4 200 kg Weight 4 200 kg Weight 4 200 kg Weight 4 200 kg Weight 4 200 kg Weight 4 200 kg Weight 4 200 kg Weight 4 200 kg Weight 4 200 kg Total 41 980 kg Count 10 times When the counting comparison function is set Label Caption Date
6. PECIFICATIONS MODEL ED3 ED 6 ED15 ED 30 1 5kg 0 5g 3kg 0 001kg 6kg 0 002kg 15kg 0 005kg 3kg 0 001kg 6kg 0 002kg 15kg 0 005kg 30kg 0 01kg CITY 31b 0 001Ib 61b 0 002Ib 151b 0 005Ib 301b 0 01b 61b 0 002Ib 151b 0 005Ib 301b 0 01Ib 601b 0 02Ib 5007 0 020z 10007 0 050z 25007 0 10z 50007 0 20z 10007 0 050z 20007 0 10z 50007 0 20z 10000z 0 50z 1 4995kg 2 999kg 5 998kg 14 995kg TARE SUBTRACTION 2 999lb 5 998lb 14 995lb 29 99lb 49 98 oz 99 95 oz 249 9 oz 499 8 oz INTERNAL TESOLUTION 1 60 000 1 60 000 1 60 000 1 60 000 EXTERNAL ESOLUTION 0 DISPLAY LCD 6 digits LAME STABLE ZERO HOLD NET HI OK LO lb oz DISPLAY PCS SUM kg Low Battery INERFACE RS 232C DEP50 DLP50 WER DC 12V 125A Adaptor PO SOURCE 6V 3 6AH Pb Battery TEMPERATURE o 0 RANGE 10 C 40 C PLATTER SIZE WD mm 306W x 2220D PRODUCT SIZE 330 W X 346 D X 107 aioe W X 346 D X 107 H PRODUCT WEIGHT 47kg When Battery is charged for 24 hours BATTERY LIFE Approximately 170 hours Back light off MINMUM VOLTAGE LEVELOFTHE About 5 6V BATTERY gt Notice Specifications are subject to change for improvement without notice 24 CT O O EE O O O O O O O O O O JR O O O O O O O O O O O O O O O O O O O O O O O O O Cr o o 000 0 0 0000000 0 0 0 0 0000 0000 E O 25 MEMO 26 N N ED series Smart Weighing Scale 9002 EDO 0011
7. RETAIL WEIGHING SOLUTION ED series Smart Weighing Scale o 2 m a w lt gt gt E CONTENTS PRECAUTIONS cccocnsensensecsecensenses 4 PREFACE sssssssssssssssssssssosssscssssssssososesse 6 DISPLAY AND KEYBOARD 6 OPERATIONS 4 7 SETUP MODE 04 18 ERROR MESSAGES ee 23 SERIAL 23 SPECIFICATIONS ee 24 PRECAUTIONS N Warning Precautions when installing the scale To ensure that you get the most from your scale please follow these instruction Do not overload beyond the Scale must be grounded to maximum weight limit minimize electricity static This will minimize defect or electric shock Do not disassemble the scale When any damage or defect occurs contact your CAS authorized dealer immediately for proper repair AD nu A a 1 1 gt A y To prevent from fire To reduce electric shock or occurring Do not place or incorrect reading Do not use the scale near spill water on the scale or Damaged cord could cause flammable or corrosive gas place tin humid condition electric shock or fire Avoid placing the scale near Insert plug firmly to wall outlet 8 Use proper Adapter heater or in direct sunlight to prevent electric shock Incorrect adapter could damage the scale N Attention Make sure to plug your scal into the Poper power outlet For maximum performance plug into a power outlet 30 mi
8. SAMPLE key then sure that PCS lamp is on If you have set sample size before the display shows 10 the display shows 0 3 If you want to increase sample size press the SAMPLE key The display shows 10 20 30 40 50 100 150 and 200 every SAMPLE time pressing the SAMPLE key 4 If you set sample size to 10 place 10 samples on the platter Press the SET key The display shows unit weight and then shows the number of samples If the display shows LACK 4 y the counting result may not correct LCD version Lack of Unit lamp is On If the display shows Err9 it is impossible to count samples because the unit weight is too small Refer to Table 1 Model ED3g Dag ED 15g DI Range of Lack 1 g Lack 2g2Lack 5g2Lack 10 g Lack Range of Low 0 5g gt En9 1g En9 209 5g En9 lt Table 1 gt O pcs 5 LI 6 Place parts on the platter then the display shows the number of parts You can also use tare function in counting mode C 4 Percent Weighing Mode 22 ca Ca h Ex Ca OR TARE 1 Press the MODE key until the display shows PErSE If you 2 If you want to use container have set reference sample before the display shows 0 0 place it and press the TARE key di _ o 3 Place reference sample on the platter and press the SAMPLE key The display shows 100 0 Make sure that reference sample bigger than 3 of maximum capac
9. T ON OFF gt COUNT LIMIT ON OFF UNIT CONVERSION gt WEIGHING Used as an ENTER key Used to calculate a unit weight ofa sample P Used to enter next digit SAMPLE A Used to have number up PRINT key PRINT W Used to have number down LIER EG o 2 Used to tum ON or OFF the power o T mn Notuse OPERATIONS 1 General Weighing The display indicates if the scale is at zero or if there is a tare entered into the scale by way of a ZERO and NET O 70 nnn LILI LI kg 1 Tum on the power The 2 When the display is not zero Place an item on the platter display shows 0 00 Make sure though there is nothing on the When the STABLE lamp is on that STABLE and ZERO lamps platter press the ZERO key read the weight are on 2 Weighing with Tare Tare is the weight of container being used for a commodity The TARE key subtracts the weight of O 70 NET O NE USU ro BDO va C75 w yy YY ESSE is RES 1 Place the container on the 2 Press the TARE key NET 3 Place an item in the platter lamp is on container 0 nnn LILI kg 4 To release the TARE function remove an item and container from the platter and press the TARE key 3 Counting Mode Ifyou want to count parts first you have to set sample size 0 0 pcs UN E 1 0 L LI ILI OR ps 1 Press the MODE key until the display shows PCSSET Make 2 Press the
10. ity Ifitis lower than 3 of maximum capacity the display shows T gt In this case increase the weight of reference sample and press the SAMPLE key SAMPLE B Ca O 5 1 Y 4 Place an item on the platter then the weight is displayed as a percentage of the reference ESO 5 Hold Function Key hold Place an item on the platter and then press the HOLD key Hold 205 w 2 HOLD is shown on the 3 Average weight is shown on display the display After average weight display 3 times HOLD function will be release automatically Auto Hold function GFF AH 8 AH 8 Un After weighing item 2 Use TARE key to select remove all of the container one of Auto Hold function from the platter press Hold key O 0 3 Press Hold key to save 4 Place an item on the platter and exit to normal mode Then weight display will show Hold The Hold blinks for two times and then the average weight blinks continuously After remove the item of the platter place another item on the platter Then display will show average weight again If you don t want use auto hold function remove the item and press hold key Display shows AH on Press tare key it will be changed AH off Then press Hold key Auto hold function will not operate 10 6 Cumulative Weight Sum The function of cumulative weight sum is to be showing the aggregate times and weight as adding the value of weighing a se
11. nutes before the usage for warm up For consistent and accurate E Avoid sudden shock to Grab on the bottom of reading maintain periodical the scale the scale when moving check by your CAS authorized dealer Keep the scale away from ER Place the scale on firm By adjusting 4 comers of other electromagnetic and temperature the scale setthe scale enerating devices consistent environment even using the builtin scale leveling indicator This may interfere with accurate reading A Ojo KY Ox Take the battery out when scale is notin use for long time Leakage from the batteries is hazardous PREFACE Thank you for the purchasing of ED series This series have been designed with CAS reliability under rigid quality control and with outstanding performance Your specialty departments can enjoy with CAS products We hope that CAS product meets your needs The user manual is designed to guide you to understand product operation and proper care of product DISPLAY AND KEYBOARD DISPLAY LACK OF UNIT Max 15 30kg Min 100g e d 5 10g D KEYBOARD D 4 PRINT SAMPLE h b KEY FUNCTIONS DES CRIPTIONS Used to set the zero point to 0 00 Used as an ESC key in Setup Mode A 3 TARE Used to enter a tare weight and used to cancel a tare weight Used to convert the mode as below WEIGHING gt pcs gt WEIGHT LIMI
12. ou can print out data every time pressing the PRINT key 8 3 Stream Print To use auto print function you have to set printer menu to Pr Str in setup mode Refer to Setup Mode Table on page 19 2 Ifthe weight is stable it is printed out continually 9 Battery Charge Warning massage is shown when the battery voltage is very low LAF At this time charge the battery a charging battery only The display will show a red lamp and the battery will begin a fast charge automatically Use only the ac adapter which comes with the scale Other AC adapter may cause damage 10 Unit conversion Kg Ib oz res pcs r r pcs U L i ib CHANGE CT EM Press press 5 on MODE keyat Use HOLD key or PRINT 3 Press SET key and weighing mode The display shows key you can set which unit you CHAnGE will display U kg or your last unit want to use Kg lb oz 4 Press the MODE key to go to the weighing mode 3 If the tare is set scale cannot change the unit SETUP MODE 1 How to Go to Setup Mode Make sure that power is OFF While pressing the PRINT key press the POWER key The display shows U SEL You can select each menu by pressing the MODE key and change the setting by pressing the HOLD or PRINT key If you press SET key you will save current setting and finish this mode To finish this mode without saving press the ZERO key
13. s the MODE key until 2 To print out label caption press the HOLD A key The display the display shows LA off It shows LA on means that label caption is not printed out ay ee aa r A 5 LI E LLON L SAMPLE PRINT SAMPLE hd 3 Press the SAMPLE P key 4 Y ou can program label caption by pressing HOLD A or WELCOM is shown on the PRINT Y key To enter next digit or previous digit press the MODE display in default or SAMPLE P key SET Press the SET key to save LA save is shown on the display Ifyou do not want to save press the ZERO key 22 ERROR MESSAGES Error Message Description Solution on Display Err 0 The Err 0 occurs when scale is not stable Remove unstable facts The Err 1 occurs when a current zero point has 2 Err 1 shifted from the last span calibration Please call your CAS dealer Err 3 The Err 3 is an overload error Please remove the weight The Err 9 is no weight error a sa 8 youmust load To sample set hour to raise in the petal tbeweight which falls a weight Ifyou have no weight on your scale you can see this error message Err 14 The Err 14 means calibration range is not Please call your CAS dealer SERIAL correct INTERFACE 7 6 6 GND 20 o 7 36 Rx 3 8 8 4 4 9 9 cu ieee D Sub D Sub Connector 9 pin Connector 9 pin 23 S
14. ter next digit the SAMPLE key press the SAMPLE P key UL an Press the SET key the display shows WL ON e 8 Ifyou setup LOW HIGH limit wrong WL ERR will be shown on the display Then you have to set it up again For example LOW 10kg HIGH 9kg High limitis lower than Low limit 9 Press the MODE key three times to go to weighing mode Suppose that the High limit of 7kg and the Low limit of 3kg are setup In this condition 878 lamp is lighted on if the weight is 4kg E lamp is lighted on if the weight is 8kg and if the weight is 2kg 8 lamp is lighted on It beeps as fixed on User Setup Mode Refer to Setup Mode Table on page 18 ME Press the MODE key until the 2 Press the HOLD A key to 3 Press the SET key the display display shows CL OFF It activate this function the display shows L00000 means the counting comparison shows CL ON function is deactivated SET PRINT SAMPLE e 4 4 Press the HOLD A or 5 Press the SET key the display 6 Press the HOLD A or PRINI keytohavenumberup shows HO0000 PRINT key to have or down To enter next digit press number up or down To enter the SAMPLE P key next digit press the SAMPLE P key LL on 7 Press the SET key the display shows CL ON Ifyou set up LOW HIGH limit wrong CL Err will be shown on the display Then you have to set it up again For example LOW 00100
15. veral times Even though power is off the scale stores data This function is only available in weighing mode CUS w 5 i Place an item on the platter 2 To add this weight press the SAMPLE key Make sure that SUM lamp is on O sum SET SET 5 8 4 To cancel last added weight press the SET key to display cumulative weight sum or aggregate times and then press the SAMPLE key The display shows S SUB 5 You can delete cumulative weight sum or aggregate times Press the SET key to display cumulative weight sum or aggregate times and then press the ZERO ESC key 6 To print out cumulative weight sum press the SET key to display cumulative weight sum or aggregate times and then press the PRINT key DEP only 7 Weight Comparison Function HI OK LOW 7 1 How to compare weight ot oFF ut on 1000 2 6 1 Press the MODE key until 2 Press the HOLD key to 3 Press the SET key to set up the display shows WL OFF activate this function the low value the display shows Tt means that weight limit display shows WL ON 000 00 function is deactivated H 3 h gt e h gt 4 Press the HOLD A or Press the SET key to set up Press the HOLD A or PRINT Y key to have number up high value the display shows PRINT V key to have number or down To enter next digit press H000 00 up or down To en
16. y ON It means that date is printed out 0000 i dYSRu PRINT SET SAMPLE co TJ 3 Press the SAMPLE P key 4 Press the HOLD A or 5 Press the SET key to save the display shows 00 00 00 PRINT Y key to havenumberup dysave is shown on the display or down To enter next digit press and then the display shows a day of the SAMPLE D key the week ut SAuE Ja 6 You can change the day by Press the SET key to save non pressing the 01 4 or Wksave is shown on the PRINT key Ifyou setup a display day of the week wrong Wk en is shown on the display 20 4Yandd ddandy SET e eg 8 Press the Hold key or Print 9 You can see that Date Press the SET key to save key you can change the pattem is changed dysave is shown on the message on display display shows a day of the 4 How to Enter Time 1 Press the MODE key until the If you do not want to print out time press the HOLD A key display shows ti ON Itmeans that time is printed out PRINT SAMPLE SET y e 3 Press the SAMPLE P key 4 Press the HOLD A or 5 Press the SET key to save to setup time 00 00 00 is PRINT Y key to have number tisave is shown on the display shown on the display up or down To enter next digit press the SAMPLE D key 5 How to Enter Label Caption LA aff LA an LA oFF P E 8 1 Pres