1. direction of the arrow marked open Close the cover of the chip card receptacle and slide locking backward Push casing top back onto the casing und fasten it with the five screws Start Up Start Up After the appropriate installation connect the LineCrypt L100 with the mains cable plug to an earthed socket The LineCrypt L100 performs a self test About 45 seconds it will begin normal operation It is not possible to set up connections with other equipment in the delivery configuration To be able to configure encrypted connections with other LineCrypt equipment or unencrypted connections with other Ethernet devices a corresponding configuration of the LineCrypt L100 is required Use the provided PC program lec to configure the LineCrypt Via the local management you also have the option of configuring authorized system administrators for remote maintenance CD configuration software The accompanying CD contains the configuration software for the LineCrypt 1100 the operating instructions for the software as well as further documents The latest information can be found in the file readme txt Operation Operation Extern Intern es On Reset O Speed O Speed u ae Oli O O Figure 5 front side In the center of the panel there are four multi colored light emitting diodes LED which are labeled On Il and Ill The On LED signals the ready status of the equipment or errors de
2. gt Authentication awarded by the Deutsche Telekom gt TrustCenter is stored on the gt NetKey Card Glossary TCP IP Internet Protocol and Transmission Control Protocol TCP is a connection oriented transport protocol for use in packet switched networks The protocol builds on the IP protocol supports the functions of the transport layer and establishes a secure connection between the entities before data transfer TCOS TeleSec Chip card Operating System Operating system for processor controlled Chip cards smart cards VPN Virtual Private Network A protected virtual sub network is set up in an unprotected network using encryption mechanisms 15 Index Authentication 12 Certificate ID 13 Chip card 12 15 Chip cards 5 Connection scheme 13 Environmental temperature 12 Ethernet 5f 9 12f IDEA 12 IP Network 14 IP Tunnel 4 14 LAN 14 LED 10f 14 NetKey Card 12 14 Operating System 141 RSA 12 self test 9f TCP IP 15 VPN 4 15 Important telephone numbers In the event of malfunctions Sales enquiries Please enter the telephone number when handing over the unit The LineCrypt fulfils the requirements of the following EU Directive 1999 5 EG For this reason the LineCrypt bears the CE mark Responsible for content T TeleSec Products Further information Internet http www telekom de t telesec e mail T Telesec telekom de Issued by Deutsche Telekom AG Edition 22
3. temperature 41 F to 104 F 5 C to 40 C Ethernet interface Ethernet interfaces 2 x 100BaseT 100 Mbps half duplex full duplex with Western RJ45 WE8 8 sockets PC interface V 24 Mini DIN 8 Chip card T TeleSec NetKey Card with TCOS 2 x 8x Payload data encryption IDEA DES or Triple DES Authentication RSA Table 2 Technical Data Glossary Glossary Certificate Authenticated allocation of a public key for an identity expressed by the digital signature of a Trust Center of Deutsche Telekom AG Each T TeleSec NetKey Card has an individual certificate Certificate ID Number in a certificate that provides the certificate with unambiguous identification Company Card gt TCOS Chip card that unlike the gt NetKey Card contains information about a closed user group Company Cards can be obtained from Deutsche Telekom if required Connection scheme Schematic diagram of possible connection variants EMC Electromagnetic compatibility The ability of an appliance installation or system to function satisfactorily in the electromagnetic environment without introducing electromagnetic interference to any appliance or system in that environment quoted from the EC EMC guideline article 1 clause 4 Ethernet The most widely used gt LAN standard Local Area Network Supports data rates of up to 10 Mbps 10Base T or 100 Mbps 100Base T IP Internet Protocol The task of the Intern
4. the LineCrypt Installation place The LineCrypt L100 comes in a 19 rack mount casing for installation in a 19 rack The installation place should be dry and free from dust The LineCrypt is designed for an environmental temperature range of 5 C bis 40 C Therefore do not expose the LineCrypt in direct sunlight and be sure that there is sufficient ventilation Installation Inserting and removing SIM chip cards The LineCrypt L100 has eight chip card slots To insert remove or replace the chip cards in the device its casing must be opened The eight chip cards must be of the same typ comany or netkey cards rar d 147 50 ee chip card chip card aa a 5 6 ule cm Em H Ar a BIETEN g s E az A chip card chip card El sz oz ar ESA 7 U2 UF 8 ZE g g D e om chip card chip card chip card chip card x reas o gt AAA O Figure 4 Seat the chip card Before opening the casing pullthe power plug Remove the five screws atthe rear side of the casing with a crosstip screwdriver Slide the casing cover off horizontally backward To replace a chip card the locking of the chip card slot in the
5. 09 03 Subjectto change without notice
6. T TeleSec LineCrypt L100 User s Guide Deutsche T Telekom Contents Overview of pictorial SYMDOIS x4 sor ri re dial La lo da 3 DAIEDITIOTES tala is elit idad toi 3 Power Tale sanctus 3 A sr 5 A O a E ne a reste aor 6 Installation place nes in see es ee T Inserting andremovngSIM chipeardssuest are ea 8 Registered trademarks trademarks and service names are used in this manual Even if they are not marked as such the relevant protection regulations apply IDEA is a trademark of Ascom Systec AG General General We strongly recommend that you read this user manual before using LineCrypt Deutsche Telekom cannot be held liable for any possible damage caused to the device or other facilities arising from the failure to follow the instructions in this manual Overview of pictorial symbols Safety symbol to warn against danger for people and property is identified with a triangular warning sign Safety notes e Allow no liquids to seep into the LineCrypt Do not plug in or detach any connections to the LineCrypt during a thunderstorm e The LineCrypt is only intended for use in dry indoor areas e Lay the cables so that no one can step on them and trip e Before any maintenance work on the LineCrypt pull out the mains plug e Only terminal equipment that complies to the SELV voltage standard may be connected to the LineCrypt L100 e Connect the device to a freely accessible earthed socket so that
7. et Protocol IP layer 3 is to transport data packets from a sender to a receiver across several networks The transmission is packet oriented connectionless and non guaranteed The data packets 13 Glossary also called datagrams are transported by the IP as independent data packets even in the case of identical senders and receivers IP guarantees neither observance of a particular sequence nor delivery to the receiver that is datagrams can be lost on account of network overload for example There are no receive acknowledgements on the IP layer IP Network Network based on the Internet Protocol Every device in the network is addressed through an IP number IP Tunnel A connection between two subnetworks which conceals the precise addresses of the communication partners At the start of the tunnel all data packets receive an additional header that refers to the tunnel end Here the external frame is removed and the original data packet is forwarded to its actual receiver LAN Local Area Network A spatially restricted network The most widely used LAN standard is Ethernet LED Light Emitting Diode For displaying the operational status of the device and of the connection LineCrypt Company Card Special chip cards with information on closed user groups Can be obtained from Deutsche Telekom if required NetKey Card SmartCard with gt TCOS Operating System The private asymmetrical key and a gt Certificate for
8. tected during the initialization The LED displays the data traffic on the network The II LED displays key exchanges and faults in the equipment management If a problem occurs during operation it will be recorded in the log file and LED III will turn to red LED On Green LineCrypt ready for operation Orange LineCrypt not ready for operation Flashing orange 1x Authorization file configuration missing 2 Internal error detected during self test LED Off no traffic Flashing red encrypted transmission Flashing green unencrypted transmission Operation LED Il Off Orange Red LED Ill Red no key exchange key exchange in progress key exchange failed problem was recorded in the log file Reading out the log file with the configuration software will turn off this LED Next to each of the ehternet sockets two multicolor LEDs labeled Speed and Lnk Act are located Speed Off Orange Green Lnk Akt Off Green Flashing green no ethernet connection link 10 Mbit 100 Mbit no ethernet connection link ethernet link active ethernet link data active transmission in progress LineCrypt s only operating control is the reset push button at the front panel It the device serves to restart the LineCrypt On restart all active links connections are disconnected The configuration will be retained Technical Data Technical Data Power supply 110 to 230 V Power consumption Max 15 VA Environmental
9. tion cable with RJ45 plug 1 Serial PC cable with mini DIN 8 plug 1 CDROM with LineCryptConfig software for Windows 95 98 ME NT 2000 XP and operating instructions Installation Connect the cable to the LineCrypt according to the connection scheme 110 230 V 100BaseT extern 100BaseT intern Router Figure 2 Connection scheme LineCryot L100 Plug the connection to your internal network into the socket marked Intern The connection to InternetGateway is made via the socket marked Extern As the pin assignment of the Ethernet socket corresponds to the pin assignment of a network card the following applies for the cable to be used e Use a crossed cable when connecting to a network card e g PC e Use an uncrossed cable when connecting to a hub or an Ethernet switch Contact Line Transmission lines LineCrypt 1 2 transmits HA 3 Not used 1 8 4 5 Reception lines LineCrypt receives 6 7 8 Not used Table 1 Allocation of the R 45 plug If you wish to manage the LineCrypt L100 locally plug the PC cable into the mini DIN 8 socket P for the local management Installation Extern Intern B O Speed O Speed OLnk Act OLnk Act Figure 3 Overview of sockets If the authorizations are based on the certificate number your communications partner requires this number You can read it with the help of a PC and the configuration software from
10. you can pull out the mains plug without delay when required Power failure The configuration remains unchanged in case of a power failure The LineCrypt L100 is not provided with an emergency operation In the event of a power failure you cannot communicate via the LineCrypt L100 wo Function Overview Function Overview The T TeleSec LineCrypt L100 provides protected data transfer via networks that uses the IP protocol The LineCrypt L100 acts as a link between a protected internal network and an unprotected external network The LineCrypt L100 is based on IP communication That means All other protocols IPX for example are not forwarded between internal and external sides by LineCrypt L100 LineCrypt L100 transfers the encrypted data through an IP Tunnel In this way two or more LineCrypt in an unprotected network allow a protected Virtual Private Network VPN to be set up The LineCrypt L100 can set up IP tunnels to LineCrypt DSL L L100 and SOHO The option of unencrypted connections with other IP equipment can also be configured The current software version 1 0 0 does not support IKE authentication and the RIP protocol O O Figure 1 LineCryot protecting your network Installation Installation Included in delivery Open the packaging and check that the contents is complete 1 LineCrypt L100 with mains cable and integrated Chip cards 1 Ethernet connec