Home

Quick Start Guide GV

image

Contents

1. Quick Start Guide GV Fisheye IP Camera Co E C GeoVision The Vision of Security Note 1 GV FE110 FE420 FE520 are excluded from Japan EU and German market 2 No memory card slot or local storage function for Argentina Thank you for purchasing GV Fisheye IP Camera This guide is designed to assist the new user in getting immediate results from the GV Fisheye IP Camera For advanced information on how to use the GV Fisheye IP Camera 2012 08 please refer to GV Fisheye IP Camera User s Manual on Software DVD English 2012 GeoVision Inc All rights reserved FE111421521 QG F 9 Introduction Welcome to the GV Fisheye IP Camera Quick Start Guide In the following sections you will learn the basic installations and configurations of GV Fisheye IP Camera For the detailed user manual see the GV Fisheye IP Camera User Manual on the GV Fisheye IP Camera Software DVD Note GV FE110 FE111 FE420 FE421 FE520 FE521 are for indoor use while GV FER521 is designed for outdoor environment Packing List e Camera Body a a fi j KoD g e Camera Cover In Ceiling Mount wy i e Camera Cover Hard Ceiling Mount t Li ks neue M a ee e Screw e Screw Hard Ceiling Mount x 3 In Ceiling Mount x 3 Li sss e Support Bracket x 3 e Plastic Screw Anchor x 3 EE Torx Wrench ve Installation Sticker Silica Gel Bag and Adhesive Tape x 2 GV FER521 only DC 12V Power Adaptor a
2. requires the ceiling board to be between 0 5 3 0 cm 0 2 1 18 in 1 Place the installation sticker on the ceiling board and cut the circle part out of the ceiling 2 Align the 3 support brackets with the holes on the back of the camera and secure using the in ceiling mount screws provided 3 For GV FER521 install the supplied cable connector to waterproof the cable Refer to step 5 in Hard Ceiling Mount for details 4 Place the fisheye camera into the ceiling opening 5 On the back side make sure the black plastic clips are slightly above the ceiling board and pointing outward 6 From the front side of the camera tighten the screws 7 Place the camera cover for in ceiling mount on top of the camera and tighten the 3 screws 3 i 2 f i C m r p i d 7 t i i z 1 Wall Mount and Ground Mount To mount the camera on a wall follow the instructions in Hard Ceiling Mount For ground mount simply place the camera on a flat surface such as a conference table Hint Mount the fisheye camera in the middle of the wall to have an excellent overview Or ensure the camera is focused on the most important areas of the room as directly as possible to have the desired detailed recognition You can use a Power over Ethernet PoE adaptor to connect the GV Fisheye IP Camera on the network and the power will be provided over the network cable Alter
3. and then LAN to begin the network settings 1 Open your web browser and type the default IP address http 192 168 0 10 The computer must be under the same network as the camera 2 In both Login and Password fields type the default value admin e if Dynamic IP Address or PPPoE is enabled and you cannot access the camera you may have to reset it to the factory default settings and then perform the network settings again Refer to section 7 to see how Gn to restore to factory default settings LAN Configuration aia aseran Ve can cakana PC AM to werk braide of LAIL nd Continued on the reverse gt 5 The Web Interface Live View GeoVision whet ane Mation Oe Cento E ven Amel Bake Borel bess Pac ca clay Sih Bamas viek firs Rete Mianaoiiend Lond No Name Play Stop Microphone Speaker Snapshot File Save Full Screen I O Control Show System OY ea Ge ei eS e Is Menu 10 Control Panel Mi Ths Cte h ns Gee ee CS ee eT Ce es Lks VIRA ar pa ja 17 Local ume POUGMT AG 17 531 Hoos time gt q Nl POCGM AG 17 513 ge d a he a ie ml Z ka y 1 a Onlene cout eB q ae z i M j f A F Ai DCK Aegisirailen Path i l CIND A Geet CAW eE a a A i z E Er E te j AEE e l i t 4 i Function Plays live video Stops playing video Listens to the audio around the ca
4. d default button This may take about 40 seconds 5 The system status LED should turn back on The process of loading default settings is completed and the camera reboots automatically Micro SD a ee ia ii l 2 F E System status LED Load default Power status LED 3 Release the default button when the status LED blinks 4 When the status LED fades the process of loading default settings is completed and the camera reboots automatically C GeoVision The Vision of Security 9F No 246 Sec 1 Neihu Rd Neihu District Taipei Taiwan Tel 886 2 8797 8376 Fax 886 2 8797 8335 support geovision com tw http www geovision com tw
5. de the computer used to upgrade firmware must be under the same network of the In this section you can see GV IPCAM fil mwate version camera a 1 In the Live View window click the Show eane System Menu button E on the right ae Directly on the Camera and select Remote Config Version v1 06 2010 09 24 Upgrade For GV FE420 FE421 FE520 FE521 FER521 2 Click the Browser button to locate the File FOAMV2_W106_100824 Cancel l imna tie Cmd ened aiyaara 1 Remove the outer shell of the camera by unscrewing the screws i img y indicated below and then removing the outer shell of the camera computer GV FE Series GV FER521 WARNING The interruption of power supply during updating causes a not only update failures but also damages to your camera In this case KCO sis please contact your sales representative and send your device back to Ab CON GeoVision for repair Uns f 3 Click the Upgrade button to process the upgrade 2 Use a pointy object such as the tip of a pen to hold down the Load For GV FE110 FE111 default button labeled below GV FE Series GV FER521 Unplug the power cable and the network cable 2 Remove the outer shell of the camera 3 Use a pointy object such as the tip of a pen to hold down the Load default button while plugging back the power cable and the network cable Load default 4 Wait until the network status LED turns off momentarily to release the Loa
6. e by entering the assigned IP address on Internet Explorer 7 x or later Note If you are using Microsoft Internet Explorer 8 0 additional settings 6 To enable the updating of images in Microsoft Internet Explorer you are required Please refer to Settings for Internet Explorer 8 Appendix A must set your browser to allow ActiveX Controls and perform a GND HNC SUNG tor wie ature one time installation of GeoVision s ActiveX component onto your computer By default the camera has a default IP address of 192 168 0 10 However when GV FE420 421 520 521 or GV FER521 connects to the LAN with a DHCP server a dynamic IP address will be assigned instead of 192 168 0 10 If no DHCP server exists the default IP address will be applied and you can follow the steps below to assign a static IP address IMPORTANT e lf Dynamic IP Address or PPPoE is enabled you need to know which IP address the camera will get from the DHCP server or ISP to log in If your camera in installed in a LAN use the GV IP Device Utility to look up its current dynamic IP address See Checking the Dynamic IP Address Chapter 2 GV Fisheye IP Camera User s Manual lf your camera uses a public dynamic IP address via PPPoE use the Dynamic DNS service to obtain a domain name linked to the camera s l changing IP address first For dynamic DNS server settings see Click Apply Advanced TCP IP Chapter 4 GV Fisheye IP Camera User s Manual 3 In the left menu select Network
7. e image of GV FE420 FE421 should be centered and slightly cropped on all four edges If the image is not centered please contact your sales representative and send your device back to GeoVision for adjustment Refer to Chapter 3 GV Fisheye IP Camera User s Manual to see how to determine if your device needs adjustment or not e Camera Modes You can choose among four view modes e Quad view Composed of four PTZ views e 360 degree Composed of two PTZ views and one 360 panoramic view e Dual 180 degree Composed of two 180 views e Single view Composed of one PTZ view 360 degree 2 PTZ amp 1 360 views oo re Ban l Dual 180 degree 2 180 views Single view 1 PTZ view _ Note When the wall mount is selected for Camera Position only one 180 view will be displayed Camera Position Select Ceiling Wall or Ground according to where the camera is mounted Adjust AutoPan Speed At Top Left Channel Select low medium or high speed to enable Auto Pan for one PTZ view at the rotation speed of your choice This option applies to Quad view 360 degree and Single view Zoom Select Zoom In or Zoom Out and then click on the image Show Source Video At Top Right Channel Shows the circular source image in the top right quadrant when Quad view is selected 360 degrees Object Tracking Tracks moving objects under 360 degree view Settings The following settings are available e Frame Rate Control You ca
8. mera Talks to the surveillance area from the local computer Takes a snapshot of live video Records live video to the local computer Switches to full screen Right click to see more options Enables the I O Control Panel or the Visual Automation Brings up these functions Alarm Notify Video and Audio Configuration Remote Config Show Camera Name and Image Enhance Displays the camera information video settings audio data rate I O device status images captured upon alarm and GPS location of the camera Also allows you to adjust image quality and install the program from the hard drive Fisheye View To enable the fisheye options right click the live view image and select Geo Fisheye Right click the image again and select Fisheye Option to see the following options e Image Alignment By default the image should be properly aligned already If not follow the steps below to align the image for each model e GV FE110 FE111 Align the circle with the outer edge of the camera image and then align it with the inner edge of the image frame to achieve optimal results Outer edge Inner edge e GV FE420 FE421 FE520 FE521 FER521 Align the red circle with the edge of the camera image You can eliminate the darker areas toward the edge of the image by making the red circle smaller but the field of view will be slightly reduced GV FE520 FE521 GV FER521 GV FE420 FE421 Note The circular sourc
9. n set the frame rate of the live view e Show Original Video in Low Resolution Shows circular source image when the resolution is low This option only works on the GV System when the fisheye camera is connected to a GV System e Screen Ratio Setting Select a ratio that best fits the display ratio of your computer You can drag and drop the PTZ view or 180 view to adjust the viewing angle O Upgrading System Firmware Restoring to Factory Default Settings GeoVision will periodically release updated firmware on the website To load You can restore the camera to factory default settings using the Web the new firmware into the GV Fisheye IP Camera read the important notes interface or directly on the camera and then follow the instructions below Using the Web Interface IMPORTANT 1 In the left menu select Management and select Tools 1 While the firmware is being updated A the power supply must not be interrupted and B do not unplug the Ethernet cable if the cable is the source of 2 Under the System Settings section click the Load Default button C GeoVision Additional Tools power supply Power over Ethernet or PoE supported rocam o r eenaa Events and Alerts Host Settings 2 Do not turn the power off for 10 minutes after the firmware is t Recordi Schot bis section you can determine a hostname and camera name for detain updated i Firmware Update 3 If you use the IP Device Utility for firmware upgra
10. natively you can use a standard network cable to connect the camera to your network and then follow the steps below to connect to power using the 5 pin data cable and the power adaptor provided Da Digital Output Red GND Black Digital Input Brown AC 24V DC 12V Yellow AC 24V DC 12V Orange oy it _ lt lt Ethernet PoE 1 Insert the yellow wire to the pin on the right side of the terminal block and the orange wire to the pin on the left side of the terminal block 2 Use a small flat tip screwdriver to secure the screws above the pins vv vy 3 Connect the DC 12V Power Adaptor to the Terminal Block Terminal Block DC 12V Power Adaptor Connecting the Power Cables Note 1 The power status LED will not be visible unless the outer shell of the camera body is removed 2 The GV FER521 comes with a PoE cable that allows you to connect to the power and network through a PoE adaptor Note that digital input and output are not supported in GV FER521 O Accessing the GV Fisheye IP Camera Once installed your GV Fisheye IP Camera is accessible on a network 4 Select Static IP address Type IP Address Subnet Mask Make sure your PC has good network connection and meet this system Router Gateway Primary DNS and Secondary DNS in the Configure requirement connection parameters section e Microsoft Internet Explorer 7 x or later 5 Click Apply The camera is now accessibl
11. nd 3 Pin or 2 Pin Terminal Block GV FE series only Cable Connector for GV FER521 only GV Fisheye IP Camera Software DVD GV NVR Quick Start Guide GV NVR Software DVD 2 Hardware Installation Hard Ceiling Mount 1 Place the installation sticker on the ceiling board The 3 red dots indicate the location of the screws 2 At the 3 red dots drill a hole slightly smaller than the plastic screw anchors provided 3 Insert the 3 plastic screw anchors in the drilled holes 4 Secure the fisheye camera with the 3 hard ceiling mount screws provided KOD 5 For GV FER521 install the supplied cable connector to waterproof the cable You should have 5 components e O O a o a Prepare an internet cable with the RJ 45 connector on one end only b Connect the internet cable to the camera cable c Paste the sticker to the camera cable and slide in all the components as shown below F s 9 d Move all the components toward the RJ 45 connector fit item 4 to item 2 secure item 3 to the camera cable and finally secure item 5 to item 2 tightly IMPORTANT ltem 5 must be secured tightly to waterproof the cable 6 Place the camera cover for hard ceiling mount on top of the camera and tighten the screws with the torx wrench provided In Ceiling Mount In Ceiling Mount allows the GV Fisheye IP Camera to be mounted into the ceiling revealing a small portion of the camera In Ceiling Mount

Download Pdf Manuals

image

Related Search

Related Contents

取扱説明書 - オーム電機  Whirlpool EHH-150F User's Manual  Samsung ST600 Lietotāja rokasgrāmata  MANUAL DE INSTALACAO.indd  Bedienungsanleitung  Model 800H API Service Manual  en pt es Instruction Manual Manual de Instruções  user manual of the program card for the car esc  - Inter-M  Administration, maintenance and troubleshooting  

Copyright © All rights reserved.