1. amp 3 4 knockouts 15A 208V 2 Pole Breaker w 1 2 amp 3 4 knockouts 15A 240V 2 Pole Breaker w 1 2 amp 3 4 knockouts 20 Amp Options 5 20R2 L5 20R L6 20R 208 L6 20R 240 L14 20R 240 20A 120V 1 Pole Breaker w 1 2 amp 3 4 knockouts 20A 208V 2 Pole Breaker w 1 2 amp 3 4 knockouts 20A 240V 2 Pole Breaker w 1 2 amp 3 4 knockouts 30 Amp Options L5 30R L6 30R 208 L6 30R 240 L14 30R 240 30A 120V 1 Pole Breaker w 1 2 amp 3 4 knockouts 30A 208V 2 Pole Breaker w 1 2 amp 3 4 knockouts 30A 240V 2 Pole Breaker w 1 2 amp 3 4 knockouts Other Options Single Position Blanking Plate Hardwire Option CABLE INSTALLATION WIRING PREPARATION POWER CABLE INSTALLATION WARNING Please read this section thoroughly Refer to the charts below when selecting cables before attempting to install wiring to this unit Power Cable and Protection Ratings Be sure that the unit is not connected to any AC mains power source or UPS before installing any Part No PDX2 wiring to this unit This should be installed by a Max Input Current 65 A qualified certified electrician _ Input Protection 65A Max Output 65A Current 32A 120V per leg Input Output Terminal Details 8 AWG 8 mm Size grounding protective earth conductors equal to cir cuit conductors Connecting Configurable Output Distribution Option to GXT 6kVA 10kVA Configurable Output GXT6000 10000 GXT6000 10000 GXT
2. Liebert Keeping Business In Business POWER PROTECTION Configurable Output Distribution for GXT 6 10kVA USER MANUAL EMERSON TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS GLOSSARY OF SYMBOLS GENERAL DESCRIPTION SYSTEM DESCRIPTION Features Standard Components Options MAJOR COMPONENTS SELECTABLE OUTPUT DISTRIBUTION 15 Amp Options 20 Amp Options 30 Amp Options Other Options CABLE INSTALLATION WIRING PREPARATION POWER CABLE INSTALLATION Connecting Configurable Output Distribution Option to GXT 6kKVA 10kVA HARDWIRE OPTION WALL MOUNT DIAGRAM DIAGRAM FOR ATTACHING UNIT TO WALL IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions that should be closely followed during installation and maintenance of this Configurable Output Distribution This product is designed for commercial industrial use only This product is not intended for use with life support and other designated critical devices Maximum load must not exceed that shown on the UPS WARNING Lethal voltages may be present within this unit even when it is apparently not operating Observe all cautions and warnings in this manual Failure to do so may result in serious injury or death Never work alone The UPStation GXT Configurable Output Distribution unit is designed for use on properly grounded earthed 120 208 240 VAC 60Hz supply for installation by qualified personnel This
3. 6000 10000 Distribution 208 208X 240X Wires HARDWIRE OPTION This product is intended to be installed by a qualified electrician only 1 Figure 1 COMPLETELY REMOVE ALL POWER FROM THE FRAME If Configurable Output Distribu tion is connected to the UPS disconnect external battery supply Remove the end cover plate to access the ter minal block Without disconnecting from the terminal block unscrew and pull out the hardwire plate s Route all wires from the hardwire plate s to the terminal block Connect the GROUND wire to the grounding bar strip GND3 Accessing terminal block 6 Connect the remaining wires in accordance with the wiring diagram located inside the end cover plate NOTE When wiring 120 V loads LINE must be alternated between TB 1 1 and TB1 3 to balance the 120 V load Connect all neutral wires to TB1 4 7 Replace the receptacle plates and the end cover plate using caution not to damage the wires WALL MOUNT DIAGRAM DIAGRAM FOR ATTACHING UNIT TO WALL Use the following diagram which shows the Configurable Output Distribution to a wall Liebert location and measurements of factory cut recommends using 1 4 20 mounting screws mounting slots when preparing to attach the PD1Xx 28 38 PD2XxX 24 31 PD3XX 20 25 Liebert Keeping Business In Business POWER PROTECTION Configurable Output Distribution for G
4. UPS equipment is intended to be installed by a qualified certified electrician who must review and approve customer supplied wiring circuit breakers intended loads and verify correct input output and earth connections to ensure compliance with technical standards and national and local electrical codes Installation instructions and warning notices are in the Cable Installation section of this manual CAUTION To reduce the risks of fire connect only to a circuit provided with maximum branch circuit overcurrent protection of 65A according to model in accordance with applicable national and local electrical codes Operate the UPS equipment in an indoor environment only in an ambient temperature range of 32 F to 104 F 0 C to 40 C Install it in a clean environment free from conductive contaminates moisture flammable liquids gases or corrosive substances GLOSSARY OF SYMBOLS Risk of electrical shock Indicates Caution followed by important instructions AC input AC output Requests the user to consult the manual Equipment grounding conductor GENERAL DESCRIPTION Congratulations on your purchase of Liebert s Features UPStation GXT Configurable Output Distribution Supports up to 10 kVA loads As with every Liebert product we stand behind our Compact design quality If you have any questions concerning this e Highly configurable configurable distribution option please feel free to e Multiple power p
5. XT 6 10kVA USER MANUAL The Company Behind the Products With over a million installations around the globe Liebert is the world leader in computer protection systems Since its founding in 1965 Liebert has developed a complete range of support and protection systems for sensitive electronics e Environmental systems close control air conditioning from 1 to 60 tons e Power conditioning and UPS with power ranges from 300 VA to more than 1000 kVA e Integrated systems that provide both environmental and power protection in a single flexible package e Monitoring and control from systems of any size or location on site or remote e Service and support through more than 100 service centers around the world and a 24 7 Customer Response Center While every precaution has been taken to ensure the accuracy and completeness of this literature Liebert Corporation assumes no responsibility and disclaims all liability for damages resulting from use of this information or for any errors or omissions 1994 Liebert Corporation All rights reserved throughout the world Specifications subject to change without notice Liebert and the Liebert logo are registered trademarks of Liebert Corporation All names referred to are trademarks or registered trademarks of their respective owners SL 23446 9 01 Technical Support United States 1050 Dearborn Drive P O Box 29186 Columbus OH 43229 1 800 222 5877 Outside the Uni
6. ath indicators contact your local sales representative or call the appropriate Technical Support number listed in the back of this manual Standard Components Provisions for hardwire output Power on indicator lamps Branch rated circuit breakers To ensure proper installation and operation of this unit please read this manual thoroughly While installation must be completed by a qualified certified electrician general operation may be performed without special training Options ee User selectable output distribution SYSTEM DESCRIPTION The Configurable Output Distribution was designed to provide maximum flexibility to business critical equipment Various output receptacle options are available from 15 A to 30 A Hardwire options are also available with or without a branch rated circuit breaker MAJOR COMPONENTS The following is a general description of each component and its functions Please review this section carefully as it will give you a better understanding as to how the UPStation GXT Configurable Output Distribution operates SELECTABLE OUTPUT DISTRIBUTION Several receptacle and hardwire options are available as user selectable output distribution These are factory configured when ordered and also allow for field upgrades Common receptacle and hardwire options include 15 Amp Options 5 15R2 L5 15R2 6 15R2 208 6 15R2 240 L6 15R2 208 L6 15R2 240 15A 120V 1 Pole Breaker w 1 2
7. ted States 614 888 0246 24 hours a day 7 days a week 1 800 222 5877 3 Phase UPS 1 800 543 2778 Environmental Control 1 800 543 2778 Italy Via Leonardo Da Vinci 8 Zona Industriale Tognana 35028 Piove Di Sacco PD 39 049 9719 111 FAX 39 049 5841 257 Asia 23F Allied Kajima Bldg 138 Gloucester Road Wanchai Hong Kong 852 2 572 2201 FAX 852 2 831 0114 Web Site www liebert com EMERSON

Download Pdf Manuals

image

Related Search

Related Contents

DAV-DZ680  steeluniversity.org  "user manual"  PREPASSR Tutorial/Reference Manual  Ryobi ZRRJ165VK Use and Care Manual  

Copyright © All rights reserved.
Failed to retrieve file