Home

TP210V Balancer Manual

image

Contents

1. LED s are flashing and beeping for 10sec this will be repeated every minute until conditions change reduce charge rate to 0 3A and carefully monitor charging conditions Charging with pulse charger Astro 109 1 Charge completion alerts may be activated during phase 3 double beeps 6 times 2 Verify the cell count setting if correct you may continue charging until finished Auto self Balancing 1 Plug the battery balancer connector into the correct balancer port DO NOT simultaneously charge battery 2 Balancer will bleed balance if balancing is necessary red LED s flashing If no red LED s flash the battery is balanced and ready for charging Precautions _ Do not connect BANK1 and BANK 2 connectors at a same time 2 Do not use in direct sun light the unit will develop heat when working and direct sun li ght can cause overheating Do not use when ambient temperature is over 85 degrees F Use and store in a dry environment Un plug the balancer from your battery pack when not in use It is possible to allow the balancer to work for many hours at a time but do not store the balancer with a battery plugged in Chee Specifications 0 1 reference voltage controlled by microcomputer chip Balance cells 2 to 10 cells in series Balance start voltage 4 1V or 3 2V for gt 0 03V imbalance Bleeding current Max 450mA Imbalance control voltage 0 005V Under voltage warning 3 3V 0 01V Over vol
2. TP 210V_LITHIUM POLYMER BALANCER User s Guide The TP 210V employs advanced balancing technology to actively balance Lithium Polymer batteries thus making charging much safer When used in concert with the Thunder Power 1010C charger a closed loop syst em is formed the safest method available for charging Lithium Polymer batteries It is important to read this manual and use the balancer correctly This balancer is intended to be used with 2 to 10 cell packs THUNDER LI POL Y SMART POWER AUTO BALANCER TP 210 SMART AUTO BALANCER AUTO CELL DETECT START ART MADE IN KOREA FOR THUNDER POWER USA Features l Auto cell detect for any 2 to 10 cell pack 2 Checks and displays battery and individual cell conditions 3 Imbalanced cell voltage warning 4 Over voltage warning 5 Red LED s light to indicate individual cells being balanced discharged 6 Alerts for full low and over charge status 7 Data port for interfacing with TP charger and other options Usage e To identify Group A and Group B for charging two packs in series The group A pack the pack connected to the A port of the balancer M UST be connected to the negative terminal of the charger as shown in the Y series connector picture on the following pages Failure to make the proper connections here will damage the balancer After you have read and attached all labels to the Y series connector and to each battery s balancing por
3. lash for 5 seconds Charge at 0 3A to balance the pack or proceed carefully with up to 1A maximum charge rate C Imbalance over 0 2V Yellow status LED off and red LED s flash for 60 seconds Battery may require repair Keep battery plugged into the balancer until balancing stops DO NOT charge the battery until balancing stops If yellow status LED flashes pack average voltage is below 3 6V Charge the pack to 3 7 Cell or above before checking packs condition You must always avoid deep discharge to this level Additional audio alert If any of the individual cells in the battery fall below 3 2V an audible beep will be emitted for 5 seconds If the pack is charged to over 4 3 V cell overcharged audible beeps will be emitted continuously The pack will need to be discharged to below 4 2 V cell before continuing use of the balancer Note when the START button pressed again the checking display will be repeated Charging 1 After checking the battery connect the battery power lead to the charger select the charge rate according to battery capacity and condition see previous steps 2 Full charge alerts Double beeps 6 times and repeats 2 times every 30 seconds STATUS LED solid on Stop charge or wait until charge is completed 3 Over charge warning Any cell voltage over 4 3V Double beep and STATUS LED flashing Please stop charging immediately 4 Imbalance over 0 2V while charging Red
4. st be connected to the Y series harness first e Connect battery packs group A to group A of the Y series connector connect group B of the Y series connector e Make sure the group A balancer connector is connected to group A on the balancer e Make sure the group A balancer connector is connected to group A on the balancer Fig 1 Bank and groups wiring diagram Bank1 For use with 2s 3s only Group A is used For use TP 6S 7S 8S packs used Group A amp Group B connector Bank2 For use with 4s 5s Only Group A is used For use TP 10s packs use both Group A amp B connector For Charging two battery packs in series you must use a marked Y series connector See opposite page page4 As packs built before 2006 require some modification To modify pack solder pin 5 yellow to pin 6 red Thunder Power USA 4720W University Avenue Las Vegas NV 89103 USA
5. t you may then connect the first battery group A to the Y series connector terminal Group A repeat step for Group B Next connect the Group A battery balancer connector to the balancer Group A re peat for the Group B battery connector If the balancer beeps you have either reversed the balance connectors or the Y series connection call Thunder Power at 702 228 8883 if a mistake is made For 2 or 3 cell packs connect battery to bank 1 Group A For 4 or 5 cell packs use bank 2 group A For single 6 7 or 8 cell pack with two balancer connectors connect battery to bank 1 group A amp B For 10 cell pack with two 6 pin connectors connect both connectors to Bank 2 group A amp B For two 4 cell or two 5 cell packs in series a Y series connector must be used use Bank2 for balancer connectors oe i Press Start button to display battery pack condition Press the Start button to display the battery pack condition If yellow status LED flashes pack average cell voltage is below 3 6V Charge the pack to 3 7 Cell or above before checking packs condition You must always avoid deep discharging to this level Conditions below are based on an individual cell voltage being 3 7V or higher Imbalance under 0 03V Yellow status LED on steady and red LED s on for 5 seconds Normal charging proceed as usual Imbalance 0 03 to 0 2V Yellow status LED off and red LED s f
6. tage warning 4 3V Full charge indicator One or more cells at 4 2V and all others within 0 01V Size 4 0 x 1 72 X 0 72 102mm x 44mm x 20mm 0 Auto self balance 0 005V cell voltage gt 4 1V cell 1 Auto self balance 0 015V cell voltage lt 4 1V cell HS OCmnNaAnNAWNE BANK 1 and BANK2 Warning Never use both bank 1 and Bank 2 simultaneously Bank 1 amp Bank 2 are connected Internally and this could cause a short Table 1 ume e oe Used for 6s 7s 8s packs Must used n conjunction wit Gnuilt connector pack Group A P Used for 9s 10s packs ce nye Une multi connector pack WARNING W When charging 2 battery packs in series you must use a marked Y series connector Both power leads and balancer leads must be wired correctly every connection If wire connection is incorrect it will cause damage to the balancer 1 Attach a group A sticker to the Black Main Negative lead of your Y series connector not the Black Jumper Lead Attach sticker group A to eee the Black Main Negative Negative Black Jumper TP6P4E 6 pin to 4 pin connector for charging two 3S packs Install group A sticker to the balancer connector of one of the batteries Install group B sticker to the balancer connector on the second battery e WARNING Make sure proper connection if connected incorrectly you will damage the balancer e Battery packs intended to charge in series mu