Home

MASTERseries QUICK START GUIDE

image

Contents

1. 12 N C Not Connected 13 Open Pins No Contact Turin Networks makes a V 35 female to DB 26 male cable which can be used with the FLEXmaster16 Part Number Length 005 0014 10 feet 005 0068 0100 25ft 005 0069 0100 50ft T1 E1 Connection Ports RJ 48C The rear adapter supports 16 T1 E1 link interfaces on the FLEXmaster16 The pinouts are as follows Pin Description l Receive Ring 2 Receive Tip 3 N C 4 Transmit Ring 5 Transmit Tip 6 7 N C 8 Chassis Ground 26 HOOUUUOUUUOOU 14 MASTERseries Release 7 0 MASTERseries Quick Start Guide LEDs LEDs 8616 2 The LEDs on the FLEXmaster16 application module are eee Module described below Status EREE Link is i Status Ethernet Status Ethernet LEDs u zZ uJ a i w W CarrierAccess LED State Description Activity No activity Top in 8 slot Blinking Yellow Activity on circuit Right in 2 slot or Connector may have a yellow or green Blinking Green LED at this position Status No connection to port Bottom in 8 slot Solid Green Port connected to a valid source Left in 2 slot Module Status LEDs MASTERseries Release 7 0 LED State Description PST Flashing Green Passed power system test Master module ALM Solid Red Alarm on a T1 E1 port or failed power system test Nolan 35 MASTERseries Quick Start Guide LEDs T1 E1 Link LEDs LED State Description FM16 1 16 Solid Red OOF Out of
2. S7ot Chassis Installation on page 20 MASTERseries Release 7 0 7 MASTERseries Quick Start Guide 2 Slot Chassis Installation Rack Mount Installation Mounting brackets for a 19 inch rack are installed on the chassis when shipped If you want to install the chassis in a 23 inch rack you must purchase 23 inch mounting brackets from Turin Networks Installation of the 2 slot chassis is as follows 1 To install the unit in a 19 inch rack attach the unit with the brackets to the rack using the screws provided 19 inch Mounting Bracket 2 To install the unit in a 23 inch rack remove the 19 inch mounting brackets and replace them with 23 inch mounting brackets purchased from Turin Networks lt lt 23 inch Mounting Bracket 3 Ground the unit by attaching ground wire from the terminal block to the frame ground WARNING THE GROUND TERMINAL ON THE POWER BLOCK MUST BE CONNECTED TO THE FRAME GROUND TO PREVENT POSSIBLE DAMAGE TO THE EQUIPMENT 8 MASTERseries Release 7 0 MASTERseries Quick Start Guide 2 Slot Chassis Installation Power Supply Installation and Cabling DANGER POSSIBLE SHOCK HAZARD EXISTS PLEASE FOLLOW INSTRUCTIONS CAREFULLY ENSURE THAT NO POWER IS PRESENT ON POWER LEADS AND THAT THE CHASSIS POWER SWITCH IS OFF WHEN PERFORMING THE PROCEDURES IN THIS SECTION This section describes the power supplies used in the 2 slot chassis and provides instructions for installing and setting
3. 2 Slot Chassis Installation Removing Adapter Strips Engine and adapter modules may have ESD adapter strips attached when shipped These adapter strips are required for 8 slot chassis installation but must be removed for 2 slot chassis installation To remove the adapter strips loosen the screws holding the strips and slide the strips off the modules Re tighten the screws ESD Adapter Strip on Adapter Module MASTERseries Release 7 0 17 MASTERseries Quick Start Guide 2 Slot Chassis Installation Application Module Installation When installing two modules in a 2 slot chassis install the first in slot 1 first slot from the left When only using one module install it in slot 2 This is to ensure optimal cooling performance To install an application module 1 Gently slide the module into the slot and press firmly to make full contact with the midplane connector of the chassis 2 Be sure that the ID tag on the engine is to the right when inserting into the chassis The text along the edge 2 SLOT DOWN should be upright 3 Secure the application module to the chassis with the screws on the faceplate of the application module When correctly installed the application module faceplate will make contact with the chassis 4 To install a second application module repeat the process for slot 2 Removing an Application Module To remove an application module from a 2 slot chassis remove the two screws
4. 707 793 4935 www TurinNetworks com PREFACE Safety Information CAUTION ALWAYS USE CAUTION WHEN INSTALLING TELEPHONE LINES READ THE CAUTIONS BELOW FOR DETAILS ON SAFETY GUIDELINES TO PREVENT INJURY The installation of a MASTERseries unit is to be performed by qualified personnel only Never touch uninsulated telephone wires and terminals unless the telephone line has been disconnected at the Network Interface NI as voltage potentials as high as 300 VAC may be present across the transmit and receive pairs Only use No 26 AWG or larger telecommunication line cord to reduce the risk of fire Never install telephone wiring during a lightning storm Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations e Refer to the installation section of this manual for a safe and proper installation procedure All wiring external to this equipment should follow the current provision of the National Electrical Code Preface Electrostatic Discharge ESD Precautions Electrostatic Discharge ESD Precautions ESD can damage processors circuit cards and other electronic components Always observe the following precautions before installing a system component 1 Do not remove a component from its protective packaging until ready to install it 2 Wear a wrist grounding strap and attach it to a metal part of the system unit before handling components If a wrist strap is not available mai
5. and the NMS port are cabled four ferrite beads are required for the seven cables as shown below J 5 te PAs dei agi ane ay Sa nO Ro ze t 24 48 VOC a a NN TA ee MASTERseries Release 7 0 19 MASTERseries Quick Start Guide 5 Slot Chassis Installation 8 Slot Chassis Installation The 8 slot chassis has eight application module slots and two power supply slots for redundant power Dimensions 5 2 in H x 10 2 in D x 19 in W Maximum depth of the shelf including cables is 12 inches a sye Tee SE ePeS es USSSS SS SE U SHES SEES LU SESESERERE LU SESE REESE LU EERE eee be ee LIT TOM TM mt HAHU M WANN NK UNE E f hin 24 48 VDC 24 48 VOC Slots 1 2 3 4 5 6 7 8 SZ Application Module Power Supply Slots Slots NOTE Blank faceplates must be installed on each open slot to be in compliance with product emission standards Supported Configurations The following table indicates the configurations supported by the 8 slot chassis Total Number of Modules For information about configurations supported by the 2 slot chassis see 2 Slot Chassis Installation on page 7 20 MASTERseries Release 7 0 MASTERseries Quick Start Guide 5 Slot Chassis Installation Rack Mount Installation Mounting brackets for a 19 inch rack are installed on the chassis when shipped If you want to install the chassis in a 23 inch rack you mu
6. that lock the module faceplate to the chassis then push the ejector handle to the right to disengage the connectors Slide the module out carefully Adapter Installation 1 Insert the adapter module into the back of the 2 slot chassis directly behind the application module installed in steps above and press firmly to make full contact with the midplane connector of the chassis Note The text along the edge 2 SLOT DOWN should be upright 2 Secure the adapter module to the chassis by tightening the screws on the faceplate ee NOTE Empty slots should always be covered with faceplate covers front and back to be in compliance with product emission standards 18 MASTERseries Release 7 0 MASTERseries Quick Start Guide 2 Slot Chassis Installation Ethernet Switch Cabling If you attach cables to the Ethernet switch ports at the front of the FLEXmasterl16 module you must install ferrite beads part number 010 0051 on the cables to meet emissions requirements Ferrite bead guidelines are as follows Up to four Ethernet cables can be grouped together within two ferrite beads The NMS cable can be grouped with Ethernet cables up to the limit of four cables within two ferrite beads Ifthe installation is limited to the backhaul Ethernet and or the NMS cable a single ferrite bead with a loop can be used Note The ferrite bead should be 4 to 5 inches from the connectors Example If all of the Ethernet ports
7. Frame or AIS Solid Green Normal link is up Flashing Red LOS Loss of Signal Solid Yellow Yellow sync alarm or RAI Indicates red alarm on the far end Flashing Loopback in progress alternating Yellow u as o z H and Green Link is disabled 36 MASTERseries Release 7 0
8. LN Turin NETWORKS MASTERSeries QUICK START GUIDE Part Number 002 0273 2010 Release 7 0 October 2008 Copyright 2008 Turin Networks All rights reserved The information presented in this manual is subject to change without notice and does not represent a commitment on the part of Turin Networks The hardware and software described herein are furnished under a license or non disclosure agreement The hardware software and manual may be used or copied only in accordance with the terms of this agreement It is against the law to reproduce transmit transcribe store in a retrieval system or translate into any medium electronic mechanical magnetic optical chemical manual or otherwise any part of this manual or software supplied with MASTERseries for any purpose other than the purchaser s personal use without the express written permission of Turin Networks The Turin Networks Logo is a registered trademark of Turin Networks FLEXengine FLEXmaster MASTERseries and OMC Companion are trademarks of Turin Networks All other brand or product names are trademarks or registration trademarks of their respective companies or organizations Corporate Contact Information Turin Technical Assistance Center E mail tech support TurinNetworks com Phone US 1 800 887 4638 Phone International Direct 1 707 665 4355 Turin Networks Inc 1415 North McDowell Blvd Petaluma CA 94954 Phone 1 707 665 4400 Fax 1
9. art Guide 2 Slot Chassis Installation Power Cable Routing To meet emissions standards the power cable must be routed away from all other cables connected to the chassis These include the alarm Ethernet NMS T1 E1 and V 35 cables As an example you might route the power cable as shown below LM u AAP SAPP FETAL TI bode Tso ee oe Ean Sa ID Wet BES J FEED A FEED B MASTERseries Release 7 0 13 MASTERseries Quick Start Guide 2 Slot Chassis Installation Alarm Contacts The alarm terminals are located next to the power entry module If you use the alarm contact feature attach leads to the appropriate terminal using the screws on the terminal block to secure them The alarm terminal block can be removed for easier lead attachment Plug the terminal block back into the alarm module when finished The following table describes the alarm terminal contacts Contact Alarm Description Major Alarm Normally Closed Common LO we oe OJ gt 5 Normally Open GO a2 amp QO MAJ ALARM MIN ALARM Minor Alarm Normally Closed Common Normally Open Ferrite Bead Install a ferrite bead part number 010 0051 with a loop on the alarm leads as shown below D f REEF fs ROOT PRL RL GE F GSES TEF PF EFEFEF 14 MASTERseries Release 7 0 MASTERseries Quick Start Guide 2 Slot Chassis Installation Alarm Lead Routing To meet emissions standards the alarm leads must be rou
10. baud and press the R key If there is no response use 9600 baud using the same approach If there is a baud rate mismatch between Procomm and the master module the master module could reboot To prevent this 1 Go to Options gt Data Options gt Setup Files 2 Select the Data tab 3 Select Terminal Options 4 Set the Enquiry Type field to OFF Other versions of Procomm might require you to navigate to the Enquiry Type field differently Consult your Procomm manual for more information Additional Settings Hardware flow control Off XON XOFF flow control Off Use DTR for hang up Off Monitor DCD carrier Off Exit on hang up Off MASTERseries Release 7 0 3 MASTERseries Quick Start Guide Local Management Logging in to the FLEXmaster Logging In After connecting with your VT Terminal Emulation software press ENTER and the Login prompt appears Default Login admin Default Password networknm E COM1 9600baud Tera Term VT File Edit Setup Control Window Help Turin Networks FLEXmaster When you log in to the FLEXmaster you start in the root mode of the command line interface CLI At this point you can issue commands through the CLI Note You may see one of the following messages immediately upon logging in Unable to open userid file Problem reading userid file The admin user can still log in You can correct this situation by adding modifying or deleting users For information about these co
11. d remove it Dual Power Feed Dual Power Supplies Attach the leads to the appropriate terminal as indicated in the following diagram Secure the leads with screws on the terminal block to tighten them Single Power Feed Dual Power Supplies Attach the leads to the appropriate terminal as indicated in the following diagram Secure the leads with screws on the terminal block to tighten them Wire Securing Screws 48VDC 48VDC or RTNA INB Return A Power Entry B RTN B NA Return B Power Entry A ARDE DC Power 24VDC Jumpers RTN A IN B Return A Power Entry B RTN B NA Return B Power Entry A WARNING THE TERMINAL oS ON THE POWER BLOCK MUST BE CONNECTED TO THE EARTH GROUND TO PREVENT POSSIBLE DAMAGE TO THE EQUIPMENT MASTERseries Release 7 0 23 MASTERseries Quick Start Guide 5 Slot Chassis Installation Alarm Terminal Block The following table describes the alarm contacts on the DC powered chassis Contact Alarm Description Major Alarm Normally Closed Common Normally Open Minor Alarm Normally Closed Common Normally Open Alarm Contact If you use the alarm contact feature install a ferrite bead part number 010 0051 with a loop MAJ AL MIN ALARM Applying Power DANGER POSSIBLE SHOCK HAZARD EXISTS FOLLOW INSTRUCTIONS CAREFULLY Wire Feed A and Feed B to a power source 1 Ensure that no power is present on the two wires to be connected 2 Remove the
12. es LED State Description Power DC input missing or failure DC input present Power Supply Installation To install the first power supply 1 Remove the blank faceplate from power supply in slot 1 2 Slide the first power supply into the empty power supply slot 3 Press firmly to make full contact with the connector in the back of the chassis 4 Tighten the screws found on the front of the power supply 5 Install a second power supply for redundancy into power supply slot 2 as in steps 1 4 DC Power 24 48 DC Power Supply The power entry modules provide DC power DC Line Input protection and isolation Fuses Each input has its own return The recommended wire gauge for Power Entry Panel connecting power is 16 to 18 gauge Alarm Contacts NOTE When using two power supplies the input power must be connected to both A and B feeds If you only power the A feed and are using two power supplies you will need to jumper between input A and input B and also between return A and return B Make this jumper the same gauge as the feed 22 MASTERseries Release 7 0 Terminal Block MASTERseries Quick Start Guide 5 Slot Chassis Installation Connect 16 18 Attach the leads to the appropriate terminal using the securing Gauge Wire Here screws on the block to tighten them The power terminal block and the alarm terminal block can be removed for easier lead attachment Pry off the block with a screwdriver an
13. following page show the positioning of the leads 4 Be sure to attach the ground wire as described in Rack Mount Installation on page 8 Ensure that no bare wire shows after the wires are installed Wire Securing Screws IMPORTANT Do not connect power yet MASTERseries Release 7 0 Il MASTERseries Quick Start Guide 2 Slot Chassis Installation If You are Using Redundant Power a Supplies Power must be connected to both A and B RTNA feeds Attach the leads to the appropriate ES terminals as indicated in the diagram at the right Earth 48VDC Ground 24VDC INB Power Entry B RTN B NA Return B Power Entry A If You are Using a Single Power Feed with Dual Power Supplies If you only power the A feed and are using two power supplies you need to jumper E between Input A and Input B and also 24VDC aiii between Return A and Return B Make this Sa IN B Power Entry B jumper the same gauge as the feed Attach the leads to the appropriate terminals as indicated in the diagram at the right RTN B INA Return B Power Entry A Ferrite Bead A ferrite bead is required on the power cable Install a ferrite bead part number 010 0051 on the power cable with a loop as shown below It is recommended that the ground wire be included in the ferrite bead D ra F Cr a a fi e y i re re EOD as PB L FEED A FEED s 12 MASTERseries Release 7 0 MASTERseries Quick St
14. later replace equipment in original shipping container and store in a safe place until ready to install Installation Environment The environment in which you are installing the Adit 600 must meet the following conditions Operating temperature range 40 to 149 F 40 to 65 C Storage temperature range 40 to 158 F 40 to 70 C Maximum operating altitude 10 000 ft 3 048 m Minimum operating altitude 197 ft 60 m below sea level Maximum non operating altitude 40 000 ft 12 192 m Relative humidity non condensing range 0 to 95 6 MASTERseries Release 7 0 MASTERseries Quick Start Guide 2 Slot Chassis Installation 2 Slot Chassis Installation The 2 slot chassis has two application module slots and two power supply slots for redundant power Dimensions 1 75 in H x 19 in W x 10 2 in D Maximum depth of the shelf including cables is 12 inches Rack Mounting 19 or 23 inch rack 1 75 Application 10 2 Module Slot 1 Application Module Slot 2 Power Supply Slot 2 Power Supply Slot 1 NOTE Blank faceplates must be installed on each empty slot to be in compliance with product emission standards Supported Configurations The following table indicates the configurations supported by the 2 slot chassis Double Triple FM16 FM16 Total Number Fan Fan TDM ATM of Modules A R E A S a ee a a For information about configurations supported by the 8 slot chassis see 8 amp
15. maining slots Retaining Screws ETHERNET LS aml W Carr rAccess Removing an Application Module To remove an application module from an 8 slot chassis remove the two screws that lock the module faceplate to the 8 slot chassis then lift up on the ejector handle labeled with the module name to disengage the connectors Slide the module out carefully Adapter Module Installation 1 Insert the adapter module into the back of the 8 slot chassis directly behind the application module installed using the application module installation procedure and press firmly to make full contact with the midplane connector of the chassis 2 Secure the adapter module to the chassis using the screws on the faceplate 28 MASTERseries Release 7 0 MASTERseries Quick Start Guide Local Management Logging in to the FLEXmaster Local Management Logging in to the FLEXmaster The following sections describe how to log in to the FLEXmaster s command line interface CLI Connection Requirements Connecting to the FLEXmaster s NMS Port Logging In Connection Requirements To use the FLEXmaster s CLI you must have the following items Laptop VT100 terminal emulation software such as HyperTerminal on your laptop Network Management cable NMS cable MASTERseries network management cable part number 80001 NM Ferrite bead part number 010 0051 for NMS cable USB to serial adapter if your la
16. mmands see the adduser moduser and deluser commands in the MASTERseries User Manual 32 MASTERseries Release 7 0 MASTERseries Quick Start Guide Connectors Connectors Engine Front 10 100Base T Ethernet RJ 45 1 8 The 10 100Base T Ethernet female port to connect to a remote management tool such as Telnet or an SNMP based Network Management System The pinouts are as follows Pin Name Description l Receive from network 2 Receive from network 3 Transmit to network 4 5 N C Not connected 6 Transmit to network 7 8 N C Not connected NMS Port The Network Management Systems NMS craft port is a RJ 45 connector with the following pinouts Pin Name Description N C Not connected Tx Data Transmit Data Rx Data Receive Data N C Not connected Ground Drain Ground N C Not connected DSR Data Set Ready DTR Data Terminal Ready ol SY AI al AIT oJ N NOTE A ferrite bead is required on this cable see Ferrite Bead on page 15 for further information MASTERseries Release 7 0 33 MASTERseries Quick Start Guide Connectors Adapter Back RS 232 Subminiature DB 26 Connector Pin Description Pin Description Z 1 Transmit Data B 2 Transmit Data A 15 Receive Clock A z 3 Receive Data B 4 Receive Clock B g 5 18 Open Pins No Contact a 6 Open Pins No Contact io 7 Signal Ground 20 DTR 8 CD RLSD 21 Open Pins No Contact 9 Open Pins No Contact 22 N C Not Connected 10 Xmit Clock A Xmit Clock B 11 External Clock B
17. not perform the following procedures to install the adapter strips MASTERseries Release 7 0 25 MASTERseries Quick Start Guide 5 Slot Chassis Installation Adapter Strip Installation on Engine 1 Slide the adapter strip under the screw heads until snug as shown in the following figure Spacers below the screw heads allow enough space to install the adapter strip without loosening the screws If the screws have been driven tight to the panel loosen them enough to allow the slotted end of the adapter strip to fit under the screw heads a F mm te 5 bal a hana ssa TYS et on oe apa LET Ea Raps wewms Ciida hab J i ae ul fi H E 2 Tighten the screws to hold the adapter strip in place Adapter Strip Installation on Adapter Module 1 Slide the adapter strip under the screw heads until snug Spacers below the screw heads allow enough space to install the adapter strip without loosening the screws If the screws have been driven tight to the panel loosen them enough to allow the slotted end of the adapter strip to fit under the screw heads 2 Tighten the screws to hold the adapter strip in place ESD Adapter Strip on Adapter Module 26 MASTERseries Release 7 0 MASTERseries Quick Start Guide 5 Slot Chassis Installation Application Module Installation FLEXmaster modules use more power than series 3 modules As a result you must install them in alternating slots NOTE M
18. ntain contact with the system unit throughout any procedure requiring ESD protection WARNING INTEGRATED CIRCUITS ICS ARE EXTREMELY SUSCEPTIBLE TO ELECTROSTATIC DISCHARGE UNLESS YOU ARE A QUALIFIED SERVICE TECHNICIAN WHO USES TOOLS AND TECHNIQUES THAT CONFORM TO ACCEPTED INDUSTRY PRACTICES DO NOT HANDLE ICs The ESD warning label appears on packages and storage bags that contain static sensitive products and components 4 MASTERseries Release 7 0 QUICK START GUIDE In this Guide Unpacking and Inspection Installation Environment m 2 Slot Chassis Installation m 8 Slot Chassis Installation Local Management Logging in to the FLEXmaster Connectors LEDs NOTE Multiple modules master slave functionality and E1 functionality are not supported in this release MASTERseries Quick Start Guide Unpacking and Inspection Unpacking and Inspection WARNING OBSERVE PRECAUTIONS FOR HANDLING ELECTROSTATIC DEVICES 1 Inspect containers for damage during shipment Report any damage to the freight carrier for possible insurance claims Compare packing list with office records Report any discrepancies to the office Open shipping containers be careful not to damage contents Inspect contents and report any damage AP a If equipment must be returned for any reason carefully repack equipment in the original shipping container with original packing materials if possible 6 If equipment is to be installed
19. ptop does not have a DB9 RS 232 port Refer to PTN 06 001 1 for more information Ferrite Bead 2 Slot Chassis For the 2 slot chassis a ferrite bead part number 010 0051 is required for the NMS cable Under certain circumstances the NMS cable can be included in ferrites with the Ethernet switch cable s See Ethernet Switch Cabling on page 19 for instructions Ferrite Bead 8 Slot Chassis For the 8 slot chassis add a ferrite bead part number 010 0051 to the NMS cable Install the bead with a single loop Installing the Bead 1 Open ferrite bead with the depressions facing up should be 4 to 5 inches from the connector RJ 45 3 Make sure that two 2 turns are inside of the ferrite bead 4 Snap the ferrite bead shut 2 Wrap the NMS cable around the ferrite bead Note The ferrite bead il NOTE The following instructions assume you are using a laptop You can also use a PC or VT 100 terminal MASTERseries Release 7 0 29 MASTERseries Quick Start Guide Local Management Logging in to the FLEXmaster Connecting to the FLEXmaster s NMS Port To connect to the FLEXmaster s management NMS port pha E 1 Insert the network management cable into the NMS port on the front of the module 2 Plug the other end of the NMS cable into the serial port on your laptop u R s i be Launch your terminal emulation program and set the following port parameters Bits per Second 9600 Data bi
20. st purchase 23 inch mounting brackets from Turin Networks 1 To install the unit in a 19 inch rack attach the unit with the brackets to the rack using the screws provided X a at i gt i j TES i e Mounting Bracket for a 19 inch rack Mounting Bracket for 23 inch rack 2 To install the unit in a 23 inch rack remove the 19 inch mounting brackets and replace them with 23 inch mounting brackets purchased from Turin Networks 3 Ground the unit a Connect ground wire 16 18 gauge from the ground terminal to earth ground b Connect the chassis ground screw to earth ground The chassis ground screw is the raised green screw on the side of the chassis When mid mounting the chassis you can replace this screw with a flat head screw if needed Ground Terminal Chassis Ground Screw WARNING THE GROUND TERMINAL ON THE POWER BLOCK MUST BE CONNECTED TO EARTH GROUND TO PREVENT POSSIBLE DAMAGE TO THE EQUIPMENT THE CHASSIS GROUND SCREW MUST ALSO BE CONNECTED TO THE EARTH GROUND MASTERseries Release 7 0 21 MASTERseries Quick Start Guide 5 Slot Chassis Installation Power The 8 slot chassis is available as a DC powered unit The wide ranging DC power supply is used for both 48 and 24 VDC applications All power supplies are redundant and load sharing DC Configurations Power Supply Input Power Feed s Fuse Wattage 24 48 VDC 20 to 60 VDC 75 W SA 250 V LEDs The LED states of both power suppli
21. ted away from all other cables connected to the chassis These include the power Ethernet NMS T1 E1 and V 35 cables As an example you might route the alarm leads as shown below cope i ez 54 7 iL tts Woje Ral eal 1D WP Bea FEED A FEED Applying Power DANGER POSSIBLE SHOCK HAZARD EXISTS PLEASE FOLLOW INSTRUCTIONS CAREFULLY After all procedures in Power Supply Installation and Cabling on page 9 and optionally Alarm Contacts on page 14 have been completed apply power as follows 1 Ifyou have not yet done so plug the power terminal block into the power entry panel 2 Apply power to the chassis by turning on the power switch A green light should appear on the power LED on the front of the power supply MASTERseries Release 7 0 15 MASTERseries Quick Start Guide 2 Slot Chassis Installation Modules WARNING STATIC PROTECTION IS REQUIRED DURING INSTALLATION PROPER HANDLING GROUNDING AND PRECAUTIONARY ESD MEASURES ARE ESSENTIAL WHEN INSTALLING AND SERVICING PARTS OR MODULES NOTE This section describes how to install application modules and adapter modules If your chassis came with modules already installed skip this section and go to Local Management Logging in to the FLEXmaster on page 29 Each module is made up of an engine or application module and an adapter module Application Module or Engine Adapter Module 16 MASTERseries Release 7 0 MASTERseries Quick Start Guide
22. terminal block from the power entry panel 3 Strip the two wires from the power source so that approximately 5 16 inch of bare wire is exposed 16 or 18 AWG insulated copper wire is recommended for power connections Insert the wires from the power source into the appropriate square holes one at a time Tighten screws to clamp wires Ensure that no bare wire shows after the wires are installed Plug the terminal block into the power entry panel Apply power to the chassis a a St A green light should appear on the power LED on the front of the power supply 24 MASTERseries Release 7 0 MASTERseries Quick Start Guide 5 Slot Chassis Installation Modules NOTE This section describes how to install application modules and adapter modules If your chassis came with modules already installed skip this section and go to Local Management Logging in to the FLEXmaster on page 29 Each module is made up ofan engine Application Module or application module and an adapter module or Engine om thst Adapter Module WARNING STATIC PROTECTION IS REQUIRED DURING INSTALLATION PROPER HANDLING GROUNDING AND PRECAUTIONARY ESD MEASURES ARE ESSENTIAL WHEN INSTALLING AND SERVICING PARTS OR MODULES Adapter Strip Installation To be compliant with EMI an adapter strip must be installed on the engine and adapter modules in an 8 slot chassis Typically adapter strips are shipped attached to the engine and adapter modules If
23. tion Power Lead Connection The 24 48 VDC power entry module provides DC power protection and isolation when the leads are properly attached Row CE ECE L amp 2 8 O 9Y FEED A FEED B a Se gt tae MAJ ALARA MIN ALARM gt CAUTION for continued protection against fisk of fire replace only with same Q type and rating of fuse ATTENTION Pour ne pas compromettre la protection contre les risques d incendie remplacer par un fusible de m me type et de mames caract ristiques nominales DC Line Input Fuses Power Entry Module Alarm Terminal Block A and B feeds Each input has its own return The labels of the power entries vary based on what version of the chassis you have FEED A IN A RTN A operates power supply A FEED B IN B RTN B operates power supply B DANGER POSSIBLE SHOCK HAZARD EXISTS PLEASE FOLLOW INSTRUCTIONS CAREFULLY ENSURE THAT NO POWER IS PRESENT ON THE POWER LEADS TO BE CONNECTED AND THAT THE CHASSIS POWER SWITCH IS OFF To connect the power leads Connect 16 18 1 Remove the power terminal block for easier lead attachment by Gauge Wire Here prying off the block with a screwdriver 2 Strip the two wires from the power source so that approximately 5 16 inch of bare wire is exposed 16 or 18 AWG insulated copper wire is recommended for power connections 3 Attach leads to the appropriate terminals using the screws on the block to secure them The illustrations on the
24. ts 8 z Parity None t Stop Bits l Flow Control None 4 Make sure that the emulation is set to VT100 in your terminal emulation W CarrierAccess program HyperTerminal Users Turin Networks recommends modifying HyperTerminal settings as described below 1 From within the HyperTerminal application select 2 x ile gt File gt Properties from the menu bar oe rd Setinos 2 Select the Settings tab Function araw and ctl keys act as Click the ASCII Setup button a S ana sens windows keys Backspace key sends e CrltH Del Ctrl H Space Ctrl H Emulation Auto detect Telnet terminal ID ANSI Backscroll buffer lines 500 Play sound when connecting or disconnecting Input Translation ASCII Setup terminal Setup Cancel 30 MASTERseries Release 7 0 MASTERseries Quick Start Guide Local Management Logging in to the FLEXmaster 4 Set the Line delay to 50 milliseconds and the ajz Character delay to 5 milliseconds ASCII Setup uP f ASCII Sendin 5 Click OK Send line ends with line feeds Echo typed characters locally Line delay 50 milliseconds Character delay milliseconds ASCII Recewng Append line feeds to incoming line ends Force incoming data to F bit ASCII M Wrap lines that exceed terminal width Procomm Users If you are unsure of the baud rate set on a module connect to that module at 19200
25. ultiple modules are not supported in this release Do not install an engine in slot 8 next to the power supplies iF SU SSRSRERE LU SERS REESE URE RS eh ee EErEE SE HCH WY WX WX AW gt a sigh r7 Q O en Q as 4 Yaq 7 D o Y S a BPD eee ee ASAI ee zeesee ees E TEES es ATM Tit on I r POWER POWER an a k i 24 48 VD i When installing the first module into the chassis it is recommended to install it into slot 1 first slot from the left 1 Gently slide the application module into slot 1 and press firmly to make full contact with the midplane connector of the chassis Master Module The master module configures the rest of the modules slaves When installing modules into the 8 slot chassis insert a module and when this module has completed its initialization link LEDs show active green then install additional modules if needed Master Slot a 8 slot Chassis awe Slot 1 A TL Insert Adapter Ze SS Module here Master Slot Slot 1 Insert Application Module here MASTERseries Release 7 0 27 MASTERseries Quick Start Guide 5 Slot Chassis Installation 2 Secure the application module to the chassis with the screws on the faceplate of the module When correctly installed the rare application module faceplate will make contact with the ED chassis 3 To install additional modules repeat the process above for the re
26. up cabling for the power supplies 24 48 VDC Power Supply FLEXmaster modules are powered by 24 48 VDC power supplies The power supplies are redundant and load sharing Power Supply Input Power DC Configuration Wattage Feed s Fuse 24 48VDC 24 65VDC input 3 15A The LED states of the power supply are as follows LED State Description R 3 24 48 VDC DC input missing or failure El EVmanias Power l CarrierA DC input present MD CarrierAccess NOTE MASTERseries Release 6 0 introduced a new 24 48 VDC power supply that is identified by a small white dot on the faceplate MD CarrierAccess 24 48 VDC Cf CV mania POWER MASTERseries Release 7 0 MASTERseries Quick Start Guide 2 Slot Chassis Installation Power Supply Installation To install the first power supply 1 Remove the blank faceplate from power supply slot 2 2 Slide the power supply halfway into the empty slot and plug the fan s power connector into the power supply Fan Power Connector a 3 Slide the power supply the rest of the way into the slot Press firmly to make full contact with the connector at the back of the chassis Insert and tighten the screws on the front of the power supply For redundant systems install a second power supply into power supply slot 1 following the same procedure except for connecting the fan 10 MASTERseries Release 7 0 MASTERseries Quick Start Guide 2 Slot Chassis Installa