1. 0001 999999 Log 09 06 04 14 40 0002 999999 New 000002 09 06 04 14 45 0003 999999 New 000003 09 06 04 14 47 0004 999999 New 000004 09 06 04 14 50 0005 000001 New 09 06 04 14 52 0006 000001 Delete 000002 09 06 04 14 55 0007 000001 New 000006 09 06 04 14 56 0008 000001 Update 000004 09 06 04 14 57 A A EPR PRA PA AS ID Log s sequence number listed by time order Admin Administrator Id operating in fingerprint attendance if no administrator set in attendance then it will display 999999 in admin Type Administrator operating mode in attendance Content The user s ID that administrator operates When administrator verify in attendance and enter into attendance interface to operate the type is log and content is blank Time The time that administrator is operating in attendance Page UP Page Down Press to choose Page Up Page Down and then press OK to switch between page up and down 21 BIOSTREAM User s Manual Input Admin ID Input the Admin Id that you want to find press OK it will display the log record that admin operates in the attendance For example Input Admin Id 000008 press OK it will display 000008 admin Id s operation log The Id is 000008 admin s log record sequence number that is operated in the fingerprint attendance but not all admins Delete Choose delete you will delete all logs Choose delete press OK it will show the following interface
2. Device ID It s the device No it s in between 1 255 IP It s the IP of fingerprint time attendance access controller and computer communication it s default is 192 168 001 033 you can changed it according to your requirement Subnet Default subnet is 255 255 255 000 and can be changed Port It s the port No which is communicate with computer default value is 5005 and can be changed Password The password for communication between fingerprint time attendance access controller and computer default is 1234 can be changed Baud rate Communicating with computer has five choices 9600 19200 38400 57600 115200 press to choose Press OK to save after setting press ESE to cancel and back the menu interface 6 USB Disk When you need U disk to export input the U disk to USB slot choose USB Disk in menu interface press OK then enter into USB interface You can import user export all users import fingerprint export fingerprint export new record export new log export all log import door configuration export door configuration and do on in this interface as following 14 BIOSTREAM User s Manual Imp user Exp all record Exp user Exp new log Imp fingerprint Exp all log Exp fingerprint Imp door Conf Exp new record Exp door Conf Imp user You should copy the USER BAK to U disk insert the U disk to device s USB slot enter into USB manager choose Imp user press OK upload users infor
3. DELETE Press Ok to delete log Through find way you can view an admin s operation log choose delete you can just delete an admin s log 11 Information You can view all information saved in attendance in information including users records and log Choose system in menu interface and then press Ok enter into the system info interface System info At this way you can view users records and log saved in attendance Press OK back to menu interface 22 BIOSTREAM User s Manual 12 Maintenance 12 1 Clean Sometimes lianr keyboard and display window should be cleaned Because of different external environment we can t give you a exact clean time but maybe the following guide will be useful for you Picture 10 1 Maintenance Introduction Item Clean It they are to dirty to see clearly then need cleaned The following introduction for your reference Don t clean too much lens can work better in oil environment Lianr If lens is covered or affect verify then need clear Please refer to the following introduction Keyboard and display window 12 2 Clean keyboard and LCD Screen In the shutdown state use wet wipes or other neutral cleaning detergent to clean keyboard and LCD screen and then dry them 12 3 Clean Lianr Clean lianr please follow the following advice 1 If dusty or gravel blow up the dirt on lens 2 Using self adhesive plasters to clean the display window War
4. E Ea EEA eda eet outed eee 16 DOY SIM A A a AI a eee A es 17 8 1 MIMOS diu AA AAA Aaa dd 18 8 2 System Sii die ia 18 8 3 Racord Sii na a A 19 NRO a e e a o he ie ts A e oh tt asd 19 9 1 View Record uc ARA A add ade 20 9 20 M0 RECO iiinan A Wade dove ca Na 20 9 3 Clear Recorda r iki e dd 21 MIMO A AA A A tn a 21 A casa tyne dedas aa esagdet sabe tenses sseeatedenbades 22 12 Maintenances viii AA A alive es ia 23 PA a aa OE Bale eas Seen ee enue 29 12 2 Clean keyboard and LCD SCreeN 2 0 ccecec ec ecee ee ee ee ee eee eeeeeeeeeeeteees 29 12 3Cl an ens ad aldo Elba Be 29 BIOSTREAM User s Manual 1 Notice for Use First thanks for using the fingerprint time attendance access controller please read the manual carefully before using to avoid unnecessary damage Don t put the devices under strong direct light places strong light can disturb collect fingerprint obviously this will result in verification can t be passed Don t use the device on holiday as much as possible the working temperature is 10 C 55 C The device will make heat if you use it outside long time it will influence the device to work maybe become response slow verification rate low If it must be used outside it s better to use sunshade and heat dissipation devices 1 1 Operational Flow Chart Set the fingerprint access controller and then operate the fingerprint registration and contrast Installation gt Registration a gt 1 2 Re
5. to edit door right Creat It s the creat time to edit current edited users End Time It s the validity of users information it sets which time the users information is valid go beyond this time the information is invalid The invalid information can t operate the device If no validity time the users information is valid forever Press Wto choose End Time then press you will see Enable is ticked M BIOSTREAM User s Manual End Time yl mi DP Enable At this time you can set the valid time press A to set valid year month and data press number key is ok and then press OK to save 4 3 View User In view user you can view User ID Name Type FP card PW and so on Press Y in the User Manager interface to choose View User press OK after loading data enter into the View User interface Userld Name Type FP Card PW 000001 User 1 0004300046 xxx Page Up Page Down Up Down Find User Id It s the number of user have 6 digit number Name It s users name Users name have to register in software if users name are registered in software and download successfully then you can view the name in this device if not then you can t see Type The users registration type it has two types user and admin FP It displays fingerprint templates which users register One user can register at most 10 fingerprints If the registered user registered 2 finge
6. BIOSTREAM User s Manual Contents MMs IESE HOR USES ai artos ean ee 2 1 1 Operational Flow Chatt ccccecec ec ec ec ec eee e ee ee eens eee eaeeeees ca eeeeeeeeeeeees 2 1 2 Recommended finger 0cccececeeeeeeeeeeeee ec ee eee eeeeeeeaeeeeaeaeeeeeseaeaeegenes 2 1 3 The way of pressing a fingerprint 0 cece ec ee ee ee ee ee ee eeee tees estates cette 2 2 Fingerprint Access controller Me Nu 0 ccccceeee eect eee e eect tees ee etee nate eeeeeaees 3 3 Fundamental CONGCEPtS a scc2 ce ncdede ihu iia tetris i Eed 3 3 1 Registration Of USEIS cccccec ec ee cece eee cece eee ea ee eaeeeeeeeaeeeateeseeeeeeneeeees 4 3 2 Verification Of USEP cc cece cece cece e eee e eect eee ee eee eae e eee ee eat eE ea tastes Enea eae 4 3 3 User s ID NUMDeT occccccccccccccnonocinononononnnononnnnnnnnnnnnnnonnnononennaneninn eae eaeeeeaeaeeaenea 4 3 4 Door Manager sc svcset se cadena ke leek deve ler ena aa a a A nes erage se 4 3 5 Initialization INterface cc cece cece cece e cence cent ee ease eee ee ee eats ea eateaeaeaeaeenenens 4 A User Managerin e a de AERA E Aaa 4 AM NEWS AA IA AE abana tau A EETA ARA 4 AD Ed Us asistan tdt EEE EEE EE E ina Enti 8 ALS NOW USOT r rE A E E N bale 13 AA Del US A E A E GaAs EE 13 40 Del AMUS At A A A aise EAA A hb eae ATS 14 Communication rare a E ees bs bes bd a ee atl eee tee See 14 6 USB Disk a Dd eR ee a 14 TIACCOSS Control ui A e R R E A E
7. a Set 2009 K 10 10 M110 Input current date in date column input the current time in time column press to change the wrong time which is input Press OK then save it 8 2 System set Choose system set press OK enter into system parameter set interface System Param Set Langue Desk Top AT Voice Beep Auto off Auto off time 999 M Auto Exit Time 90 S LockTime 000 5 Dup confirm 000 S ok Cancel Langue Set the display langue in fingerprint time attendance You can choose Chinese or English If you choose Chinese it will display Chinese press to choose Chinese or English Desk Top You can choose picture or clock for attendance desk Press to choose picture or clock Voice You can choose voice prompt or no voice prompt Press to choose voice Yes or No Yes is have voice prompt in attendance No is no voice Beep You can choose open or close beep Press to choose Yes or No choose Yes there will be a beep in device choose No then no voice Auto off Close fingerprint attendance in designated time Press to choose auto off Yes or No set Auto off time The auto of time is between 1 255 minutes input 0 then no auto off time function Auto Exit Time The time is between 1 255 seconds For example If you set time is 5 seconds after staying 5 seconds in a interface the attendance will be back to main menu If the set time is 0 then it w
8. commended finger Recommended finger Forefinger middle finger or the fourth finger avoid using the thumb and little finger because they are not flexible when press the collecting window 1 3 The way of pressing a fingerprint 1 The correct way of pressing a fingerprint Press the finger flat on the collecting window The center of the finger should be at the center of the window 2 A few incorrect ways of pressing Perpendicular Side way BIOSTREAM User s Manual Leaning Down way Note please use the correct method to press Our company does not bear the result of reducing identifying ability due to the inappropriate operation of the users Our company retains the right to explain and modify this 2 Fingerprint Access controller menu 3 Fundamental concepts 3 1 Registration of Users Registration is the process to create an ID number for the customer and then scan their fingerprint two times to form a characteristic number This characteristic number will be stored in the storage chip as a formwork Through comparing the pre stored formwork with the scanned fingerprint the identity of the user can be confirmed A pre registered user can check in at certain attendance recording device locations the process will take around 2 seconds The same ID number can register for up to 10 different fingerprints so that users can have more selections for verification Theoretically each finger of each hand should be registe
9. ew User e Del User e Del All User Note When register a new user you can choose register to be a manager or a user In order to security the device the fingerprint time access controller offers to set manager to avoid unauthorized users changing device data 4 1 New User If there isn t registration administrator anyone can register users but if there is it must be the administrator to verify that can register new users Starting register user you must verify your ID press OK press your fingerprint or punch card or input user name and password then verify Note If there isn t registration administrator you don t need verify After verified enter into the following menu e gt User Communication USB Disk Access control System Record Log Information Sunday 2009 06 07 18 08 03 Choose User press OK it will show A BIOSTREAM User s Manual User Manager New User New User Then the background of New User will become press OK to add new user New User User ID Input user number you want to register in User ID 6 numbers The number is in between 1 999999 corresponding employee No in software Finger Input user ID press Wand choose Finger Register it will display aFinger Register it means that you choose finger register Press OK enter into the finger register interface BIOSTREAM User s Manual Fingerprin
10. hange to blue press choose admin or user which you want to register Door Right It s to set the access level for users It has 0 16 levels O means user can access anytime no access control 16 means the user can t access anytime no right to open door 1 15 is corresponding with software access level 1 15 level 1 is to access level 1 the rest can be done in the same manner Press Y and choose one of level the door right column will change to blue press choose the door right level After finishing press OK and save it the new user is successful After adding successfully you can verify the registration type for user setting If the registration type is finger register press fingerprint on initializing interface if verify successfully you can hear Thank you and the screen will display 000001 If verify fail the fingerprint will tell you Try again and display Try again Then back to initializing interface in a very long time If the registration type is password register pressing number keys in the initializing interface to input user ID screen will display BIOSTREAM User s Manual Password confirm User Password J OK Cancel Input your user ID and password press OK if verify successfully it will show Success If verify fail the device will tell you fail and display Fail If it s registered by card brush card at keyboard area in the initializing interface
11. ill enter into the records view interface Records View ID Userld Name Time Mode 000001 000001 09 0607 18 10 F 000002 000001 09 06 08 08 30 C 000003 000006 09 06 08 08 30 PW Page Up Page Down 1 2 ID It s sequence number listed in order by time The earliest record is 000001 and so on User Id User s ID Name User s name The name can be registered in software after that it will be displayed in fingerprint attendance Time User s attendance time in fingerprint attendance Mode User s attendance mode Press A V to choose next page press OK to view next page Press OK to view previous page 9 2 Find record Through Find record you can find user s attendance record quickly Choose find record press OK and enter into the Input User Id interface Input User Id Please input User Id ok Cancel Input the User Id that you want to find press OK after data is loaded it will transfer to user s record interface 20 9 3 Clear Record Choose Clear Record press OK and enter into DELETE interface DILEME Yes Press OK if you make sure to delete press ESE to cancel delete record 10 Log Delete now BIOSTREAM User s Manual Log keeps all operation in fingerprint attendance Choose log in menu interface press OK and enter into Log Manager interface Log Manager Tso ei Ea en ee
12. ill not auto back to menu interface but stay at the operation interface always and need manually operate back to menu interface 18 BIOSTREAM User s Manual Lock time It s the time length that after verify fingerprint the unit is second and value range is 1 255 for example if the lock time is 0 then the fingerprint attendance just to be used for attendance Dup Confirm In duplicate time though users sign in many times just keep one record Press OK after all parameter set well then it will display Success 8 3 Record Set Choose record set press OK and enter into record set interface Record Set The most record template of fingerprint attendance is 80000 1 000 records per day For example The record alarm is set 75000 template then when the records in fingerprint attendance is 75000 the fingerprint attendance will alarm at this time you have to collect data from fingerprint attendance as soon as possible 9 Record Record includes view record find record and clear record Choose Record in menu interface press OK enter into record manage interface as following Record Manage View Record Find Record Clear Record 19 BIOSTREAM User s Manual 9 1 View Record View Record records users detail information of attendance and access in fingerprint attendance It can view ID User Id name time and mode Choose view record press OK it will display data loading after it finish it w
13. it will prompt Thank you if verify successfully and display 000001 4 2 Edit User Choose Edit User in the user manager interface press OK it will display Please input User ID interface Input User Id Please input User Id BIOSTREAM User s Manual Input the user Id you want to edit enter into the edit user interface ID Name Cs ME PW Regist Card Regist Fingerprint Regist Del F Del C Role Moer El Door Right Creat End Time E oa M Eoo D L Enable OK Cancel In the edit user interface you can register user password card fingerprint or change or delete edit user role door right Press A Y to choose one which you need edit the choosen one will display blue backgroud and white letter PW If users set password when registering it will display x behind PW press Wto choose x x press OK to enter into the edit password interface Password Input old password Input new password Input again OK Cancel Input old password and make a new password then press OK and save If no password when registering you can set password for users Choose Register in PW press OK enter into password registration interface Password BIOSTREAM User s Manual Please enter password Please enter again OK Cancel Input password press OK to save after setting Card If user register card when registering i
14. mation saved in U disk to fingerprint device Exp user Insert U disk to USB slot enter into USB manager press Y choose Exp user press OK to download users information After finishing press ESC back to menu interface take out the U disk the USER BAK will be saved in U disk Note If operate successfully it will prompt export successfully if fail please check whether insert U disk Imp fingerprint Insert U disk to USB slot enter into USB manager press Wto choose Imp fingerprint press OK upload the users fingerprint saved in U disk to fingerprint attendance Exp fingerprint Insert U disk to USB slot enter into USB manager press OK download the fingerprint saved in fingerprint attendance to U disk After it s done press ESC back to menu interface take out U disk the USERF BAK will be saved in U disk Exp new record Insert U disk to USB slot enter into USB manager choose Exp new record press OK to download new record After its done press ESC back to menu interface take out U disk NAR BAK new record of attendance and access will be saved in U disk Exp all record Insert U disk to USB slot enter into USB manager choose Exp all record press OK to download all record of fingerprint attendance After it s done press ESC back to menu interface take out U disk AAR BAK all record of attendance and access will be saved in U disk Exp new log Insert U disk to USB slot enter into USB manager choose Exp new log pre
15. ning Don t use water and other cleaner to clean it maybe damage the lens 3 Using fine without flocky cloth to clean Be careful don t scratch the lens If there is flocky on lens blow it up after the lens dried Chinatek Inc Room102 Bld2 Xincun Road1759 Putuo District Shanghai City P R China 200333 Emal sales tekchina cn Tel 86 21 6260 7986 Fax 86 21 6260 7928 23
16. r access access whole day 00 00 23 59 or the end time in period is above the begin time Users can set each period according to actual need For example you can set Saturday and Sunday can t access work time from Monday to Friday can access Let s take set level 1 as a example other levels operation is the same with level 1 Operation steps as following Choose Door Right in the menu interface press OK and enter into the Door Manage interface it will display 15 levels Door Manage Level 1 Level2 _Level3 l Door Level 1 Monday Choose Monday press OK enter into Monday period set interface 16 BIOSTREAM User s Manual Door Level 1 Monday period set Pressing the No key to input time delete it with x if input wrongly press OK to save it after setting if set successfully it will prompt Success Special day setting The special day setting has Date setting but Monday setting not Choose Spday1 press OK enter into Spday setting interface Input the date of special day in Date other period setting is the same with week setting 8 System System set includes time set system set and record set Choose System in menu interface press OK to enter into system set interface System Set Time set 17 BIOSTREAM User s Manual 8 1 Time set Set the current date and time displayed in fingerprint device screen Chose time set press OK enter into set time interface System Dat
17. red Then when a finger of the user is injured he she can use the other healthy fingers to finish checking in Generally two fingers are recommended so that the user can use any of the two fingers to verify This helps to avoid the situation when he she forget which finger was registered 3 2 Verification of user When the user presses the fingerprint on the collecting device or types in an ID number and then types in the password or the fingerprint this process is called verification The system will send the information on whether the verification is successful or not The successful comparison will be stored in the device 3 3 User s ID Number Registration Number The users will be given an ID number when they start registering When they verify their fingerprints this number will be used to relate the characteristic of the fingerprint formwork or the password The ID number is typed in by using the number key board 3 4 Door Manage BIOSTREAM fingerprint time attendance has 15 level door manage users can choose one of them the period of time settled by level decides the open door time BIOSTREAM User s Manual 3 5 Initialization Interface After connecting power to the equipment press on power to turn on the equipment the first interface that we will see on screen is the initialization interface 4 User Manager The first chapter will introduce how to manage users in the time attendance including e New User e Edit User e Vi
18. rprints it will display 2 in FP if no registered fingerprint then no display Card It displays the card No which is registered If user register card No is 0004300046 then it will display 0004300046 if no registered card then no display PW It displays if users set password no password then no display In the View User interface press A W to choose Page Up or Page Down press OK to switch pages choose Up or Down then you can see the last or next user information the background of choosen user information will changed to black through find way you can find quickly which you want to view user Press W choose Find press OK it will display 12 BIOSTREAM User s Manual Input User Id Press OK or ESC back to the User Info interface 4 4 Del User Choose Del User in the User Manager interface press OK then you will see Del User Input the user Id that you want to delete press OK and then it will display DELETE Yes Press OK to delete the user 13 BIOSTREAM User s Manual 4 5 Del All User Press Wto choose Del All User press OK then you can delete all users in the device 5 Communication Press Win the menu interface to choose Communication press OK to enter into Net Set interface Net Set Device ID 001 IP 192 168 001 033 Subnel 255 255 255 000 port 5005 password 1234 baud rate 115200 ok Cancel
19. ss OK to download new log of fingerprint attendance After it s done press ESC back to menu interface take out U disk NMR BAK will be saved in U disk Exp all log Insert U disk to USB slot enter into USB manager choose Exp all log press OK to download all log of fingerprint attendance After its done press ESC back to menu interface take out U disk AMR BAK will be saved in U disk Imp door conf First you should copy DOOR BAK to U disk insert U disk to USB slot enter into USB manager choose Imp door conf upload door configuration information saved in U disk to fingerprint attendance Exp door conf Insert U disk to USB slot enter into USB manager choose Exp door conf press OK to download the door configuration information of fingerprint attendance After it s done press ESC back to menu interface take out U disk DOOR bAK will be saved in U disk 15 BIOSTREAM User s Manual 7 Access Control Access Control is to set access time period and level for users BBOSTREAM offers 15 levels each level can set from Monday to Sunday and 5 special days Each day includes four periods that is period 1 period 2 period 3 and period 4 Each period is the valid period of 24 hours in each day According to 24 hours each period can be exactly to minutes If the end time is the begin time 00 00 00 00 it means forbid whole day if the end time is above the begin time 00 00 23 59 it means it s valid in this time Valid period fo
20. t register ID 1 Mode finger Please press finger Follow the instruction to press the same finger twice If the registration is successful it will display Success and show V ID Card If choose card registration press Y and choose ID Card it will display ELARITEE press OK enter into the card register interface Card register ID 1 Mode Card Card ID Please slot card Put the proximity card on number keyboard of fingerprint LCD screen will display card number of proximity card if the registration is successful it will prompt card registration is success and show j Password If choose the password to register press Y and choose Password it will display Password Register press OK enter into the password register interface Password Please enter password _ Please enter again OK Cancel Input password in Please enter password the password length is 1 6 and the number is in between 1 999999 enter the password again in Please enter again Press to delete if press BIOSTREAM User s Manual wrong number Press OK after setting password if it s successful it will be back to Password Register interface and write V Note When adding user in order to add successfully you must choose one verification type User Role It has two type users Admin and user Press Y and choose one of them and you will see the user role c
21. t will display the card no behind the Card if it must be edited press Wchoose the card No behind Card press OK then enter into card register interface Card register ID 1 Mode Card Card ID Please slot card Put the card to keyboard area to register if success it will tell you Card register success if not choosing card register when users registering you can register card now the method is with above Fingerprint A user can register at most 10 fingerprints if register fingerprint when users registration then you can delete it or register other fingerprint Press W choose Register behind Fingerprint press OK enter into fingerprint register interface 10 BIOSTREAM User s Manual Fingerprint register ID 1 Mode finger Please press finger Press twice with the same finger continuously on the fingerprint reader if success it will display Fingerprint register ID 1 Mode finger Success Del F Del C Delete fingerprint card for the registered users Press A V choose Del F or Del C press OK DEERE Delete now Yes No Press OK to delete and ESE to cancel The interface will be back to User Info after pressing OK to delete and you will see Del F or Del C changed to Del Cl Role Press Y choose this column to change role of users which were registered Door Right Press Y choose this one

Download Pdf Manuals

image

Related Search

Related Contents

トイレビ由エヌクリ国ン 取扱説明書  Manual de usuario  Users guide and maintenance manual All  AN-SNAP V4 User Manual - Australian Health Services Research  Craftsman 22 HP V-Twin Kohler 46 Zero Turn Riding Mower Manufacturer's Warranty  Canada - Buyandsell.gc.ca  Lanier 5813 User's Manual  CALESCO Mirrorheater  Samsung SP42Q2HL User's Manual  PWA HMIS Workflow & Data Quality Guide 2-18  