Home
Roller Shutter Remote Control System User Manual
Contents
1. The connections are voltage free with no connection to VE or GND The relay connec tions have a minimum creepage distance greater than 4mm and are CATII rated to 220V Both relays share the COMMON terminal They can be used to operate different pieces of equipment only if the power supply for each piece of equipment is isolated from each other or share a common ground rail 5 Setup 5 1 SIM Keep Alive Text When using a Pay As You Go PAYG SIM card to avoid SIM card deactivation the sys tem can periodically send a SMS text message to keep the SIM active Ensure the SIM card has sufficient credit to make a call or text even if the call goes unanswered To setup the Keep Alive Text function the following SMS text message is sent to the system SMS lt space gt number frequency enables periodic text message sending e g SMS 07000000000 10 text 07000000000 every 10 days SMS Off disables periodic text message sending Frequency number of days interval Most UK networks require the equivalent soend of one one minute call per quarter Itis recommended a text is sent at least once per month 28 days 5 2 Signal Strength Indicator When setting up the system it is important to know the strength of signal for reliable opera tion To receive a message showing the Received Signal Strength Indicator RSSI the CSQ command is sent to the system as follows CSQ When the system SIM card has sufficient credit a SMS text messag
2. Number Setup The system is controlled by the master GSM mobile phone numbers see 2 2 Number Types The system must first be associated with at least one master phone s number before it can be used To do this the supplied 2 54mm jumper connector must be fitted to pins 3 amp 4 on HDR1 as shown in red in Figure 1 Do not connect the jumper to any other pins or damage may result The master phone number must then be sent via a SMS text message to the system phone number as follows MASTER lt space gt number For example if the master telephone number is 07000 000 000 RSMS Enable enables the reset text message RSMS Disable disables the reset text message PSMS Enable enables the power up text message PSMS Disable disables the power up text message 6 Installation 6 1 Power Connection A fused DC power supply of between 12 and 24VDC should be used with this product The power connection should be made to the terminals labelled VE and GND C10 ALPHA 1 81 4 Please note if using this equipment in a motor vehicle please consult Advent Controls prior to fitting support adventcontrols co uk 6 2 Output Connection The relay outputs have Normally Open NO and Normally Closed NC relative to COM mon COM connections These can be actuated in a momentary operation or can be toggled see 3 Setup
3. The RTIME command is specified in seconds and can be set from Is to 255s Most calls will require at least 15s for connection which is included in RTIME RTIME 45 sets the maximum ring time to 45 seconds 4 3 Changing the Maximum Call Time The maximum time limit for an answered call is set using the CTIME command The default time limit is 45s The CTIME command is specified in seconds and can be set from Is to 255s CTIME 45 sets the maximum call time to 45 seconds 4 4 Changing the Maximum Line Silence Time The maximum time for which a silent call will remain connected is set using the SILENCE command This is useful were a call may be redirected to voicemail The silence during recording will cause the system to hang the call The default silence time is 15s and can be set from Is to 255s SILENCE 25 sets the maximum line silence time to 25 seconds 1 second activation time 250 second activation time for hash relay 1 minute activation time for star relay 16 hour 16 x 60mins activation time both relays e g rlytime 10 rlytime 250s Rlytime 1m RLYTIME 960m 3 9 De activating Voicemail In order to fully control the relay action whilst using Ring Mode it may be necessary to deactivate the SIM card voicemail call divert The network command for deactivating voicemail is O004 To deactivate all incoming diverts 002 not recommended To use the code the code is entered like a telephone n
4. necessary to enter the international dialling code format of the telephone number i e for 07000000000 only the characters shown in BOLD text are considered The ADD command is used to add a new telephone number To add a new number any master phone must send the following SMS text message to the system telephone number add lt space gt number e g Add 07000000000 If TEXTRES is enabled the system will respond with the Operation Successful message 2 6 Removing a User Number The REMOVE command is used to remove an existing telephone number To remove an existing telephone number any master phone must send the following SMS text message remove lt space gt number e g REMOVE 07000000000 If TEXTRES is enabled the system will resoond with the Operation Successful message If the number is not found the Operation Failed message will be sent by the system 2 7 Viewing the Valid Number List The system can send a SMS text message containing a complete list of valid user numbers to any master phone To receive the list of numbers the LIST command is used The master phone must send the following SMS text message to the system List No further characters are required and are ignored if received The response format shows the last 8 digits of the stored number followed by a space and the next number and so on the master will not appear in the list but will also be valid The numbers are in the reverse order to the order
5. relay The twin output allows the for the remote control of roller shutters and garage doors which require separate open and close control The active whilst ringing and DTMF features allow control of deadman inputs where the user must continuously activate the shutter until it is fully open or closed Both relays can be activated by a call or SMS text from up to 512 stored telephone numbers or can be configured to activate when receiving a call from any number By default the call will not be answered and hence costs the caller nothing However the system can also be set to reject the call if desired or connect a call for DIMF keypad control of the relays Setup and operation is performed by simple SMS text messages including adding and remov ing user telephone numbers A complete list of accepted telephone numbers can be viewed via SMS text message The memory can also be scanned to see if it contains an individual number and the result is disolayed by the on board LED and if enabled see 2 10 TEXTRES by SMS text message The output relays have both Normally Open NO and Normally Closed NC with Common COM connections The action of the relay can be a single timed actuation from either 1s to 999s or 1 to 999 minutes or they can be set to toggle between calls The relays can also be set to remain active whilst the line is ringing making the board suitable for deadman control Ei ther relay can be set to respond to calls or the system
6. 7 SMS Command Set Summary ADD number Add User Number Ad t C t l CALL LIST Call Handling ven on ro S CLEARALL Also clears MASTER CHANNEL Call Channel Select CLOSE Activate CLOSE Relay CONNECT NONE Connect Call Condition CSQ Get RSSI CTIME lt seconds gt Set Call Maximum Time Limit Q U A D B q n d GSM CUSTOM Custom input message r DIAL number Dial Number on Receipt TWi n Relay Boa ra LIST List All Numbers MASTER number Add Master User MUSER DISABLE ENABLE Treat all users as Master e 2 OFF Deactivate default Relay Twin B2 05 Firmwa re 2 1 1 OFF Deactivate Relay OFF Deactivate x Relay ON Activate default Relay ON Activate x Relay ON Activate Relay ON lt seconds gt On for lt seconds gt seconds ON lt minutes gt m On for lt minutes gt minutes OPEN Activate OPEN Relay PRGSIM Purge Inbox PSMS Enable Disable Power Up Text Alert QUERY QNUM number Find Number in Memory REJECT ALL NEVER Call Handling REMOVE number Remove Number RESET Reset Settings to Defaults RLYMODE PULSE TOGGLE Relay Mode Toggle Pulse RLYTIME lt seconds gt default 3s RLYTIME lt minutes gt m relay time in minutes O p e n O n E Ca Twi n O utp ut RSMS Enable Disable Reset Text Alert Network RTIME lt seconds gt Maximum Ring Time A C t S T SILENCE lt seconds gt Maximum Line Silence Time C C ess O n ro ys e m SMS number interval days PAYG Keep Alive for GSM850MHz GSM900MHz SMS OFF switch off KA T
7. ALT alternate between x and on each call 3 3 Call Reject By default any call to the system will be allowed to ring indefinitely or up to the host net work time limit This is to avoid calls being diverted to voicemail when rejected by the system However the system can be instructed to reject hang up calls using the REJECT commana REJECT ALL rejects all valid calls The reject command can also be used to determine the status of the relay when in tog gle mode by sending the following command REJECT OPEN rejects the call when the call is deactivating the relay REJECT NONE disables all call rejection 3 4 Connecting a Call By default when called the system is set to ring indefinitely or up to the host network time limit However the system can be set to connect a call which allows the user to control the output relays using the telephone DTMF keypad e g CONNECT Enable connect when input high connect disable disable call connection 3 5 DTMF Keypad Control A caller may operate the output relays using the DIMF keypad on their telephone Note most mobile phones will not allow the continuous transmission of DIMF tones and instead will just send a short tone burst This makes control via mobile phone impossible To enable DTMF control the call must be answered by the board This is achieved by sending the CONNECT ENABLE command as described in Section 3 4 The star relay is activated by pressing and holding t
8. can be set to alternate which relay is activated by a call 1 2 Technical Specification Power Supply 12 24VDC 500mA Max 10 15mA idle Relay Output 5A Max CATII 220VAC SIM 1 8 3 6V Compliant with GSM Phase 2 2 Class 4 2W 850 900 MHz Class 1 IW 1800 1900 MHz Antenna 50Q U FL 1 3 Number Types When adding a telephone number to the system it can be set up as either a master number or a user number There is soace for 512 numbers and each number can be set up as either type of number For example you may wish to have 200 masters and 312 users Both number groups can operate the output relay by SMS text or by calling the board Master Numbers These numbers are used to make changes to board including adding other numbers At least one master number must be set up when the board is first used see section 2 3 Once one master number is set up it can then be used to set up other master numbers Example Master Number setup command Master 07000000000 User Numbers User numbers are only able to operate the relay output This can be via SMS text or by call ing the board Unless MUSER is enabled this makes all numbers master numbers User num bers cannot access any command functions Example User Number setup command Add 07000000000 2 Operation 2 1 Registration A valid GSM Subscriber Identity Module SIM card must be present in the SIM holder for the system to operate Immediately on power up the system will attemp
9. conds ON Im activates the star relay for 1 minute ON 960m 16 hour 16 x 60mins activation time OFF deactivates the default relay under all conditions OFF deactivates the hash relay If the system loses power the relay state is restored when the power is reconnected QUERY lt space gt number or QNUM lt space gt number NB the number should be the full number not the 8 digit truncated number If the number is present the LED will flash 4 times and if not in the memory the LED will light twice for 2 seconds If TEXTRES is enabled an SMS text message will be sent with the result 2 9 Clearing All Numbers and Settings The CLEARALL Command is used to erase all stored user and master numbers To erase alll numbers the following SMS text message is sent by a master number CLEARALL No response is sent by the system to acknowledge the command 2 10 Result Acknowledgement Message The system can be setup to send a SMS text message to acknowledge a command This acknowledges the result of the last command processed such as adding a new user num ber The SIM card in the system must have sufficient credit for sending SMS text messages To enable disable the service the following text message is sent by the master number TEXTRES enable or also valid TEXTRES e TEXTRES DISABLE or also valid TEXTRES d The result message Operation Successful is sent when the service is enabled 3 Relay Operation Access Control 3 1 Enabl
10. e is sent to the number which sent the command displaying the current RSSI e g gt RSSI 21 The RSSI can be converted to an approximate Signal to Noise Ratio SNR in decibels us ing the following formula RSSI dBm 113 2x CSQ value It is recommended that the minimum signal level for the installation is 15 83dBm to ensure reliable operation The system will operate below 100dBm but may become unresponsive at times To achieve an improved RSSI the standard antenna can be upgraded to a model with higher gain and or the antenna should be positioned in an area with less physical ob struction An extension lead can be attached to the SMA connector on the PCB to lo cate the antenna away from the control unit housing 5 3 Power Up Reset Text Message The system can send an message to all the text numbers when a system reset or power up has occurred This can be due to network failure or power cycling power off followed by power on Note the system repeatedly resets during network outage You will only receive 1 message after a network outage For further information please view page 12 htto www adventcontrols co uk Aloha_v2 04 F2 11 odf MASTER 07000000000 Also valid are the following Master 07000000000 and master 07000000000 The following messages are invalid master 07000 000 000 spaces in the number masterO7000000000 no space after master The result LED LED2 will flash two times fo indicate the ma
11. ematic Diagram 15 7 Command Set Summary 16 6 5 Schematic Diagram 6 3 Antenna Connection The standard antenna can be used where a good signal exists In areas with a poor signal an external antenna is recommended connected via RG174 coaxial cable The system antenna connection is a male Hirose U FL connector It is not recom mended to use an extension greater than 3m in length 3 1 2 6 1 25 o 18 0 35 l Jl CNS aNoN 74 to 9 0 9 PIS rh JAS cS SF _ 1 2Max Note 3 6 4 Mounting The PCB has been designed to fit into a Hammond 1591B enclosure When mount ing the unit into such an enclosure the enclosure must be modified to allow for the antenna coaxial cable to be connected When mounting in a metal cabinet an external antenna must be used connected using 500hm impedance coaxial cable If required please contact support adventcontrols co uk for assistance E LIGHT GUIDE 2 PRONEN BHT2 05 aa ie LIGHT GUIDE 1 LIGHT GUIDE 3 z m ALPHA a allaa LID FASTENERS M3 x 10 mm Screws for FRABS Polycarb eae 4 x 1 2 Self Tapping for GPABS FLANGED LID Mounting Heles fer 6 4 screws M3 5 M45 Brass Inserts in FRABS and Polycarh No inserts in GPABS EXPLODED VIEW OF ENCOSURE 1 Introduction The Advent Controls GSM B2 05 Relay Board has been primarily designed for security applica tions although can be used as a general purpose call SMS activated
12. ext DCS1800MHz amp PCS1900MHz STATUS Get Relay and Input Status TEXTRES DIS Result Acknowledgement TEXTNUM number Text Alert Numbers EX www adventcontrols co uk Advent Controls Developed and Manufactured by Advent Controls Ltd Liverpool UK EMC EMI Compliance Statement CE Mark Declaration of Conformance Manufacturer s Disclaimer Statement The information in this document is subject to change without notice and does not represent a commitment on the part of the vendor No warranty or representation either expressed or implied is made with respect to the quality accuracy or fitness for any particular purpose of this document The manufacturer reserves the right to make changes to the content of this document and or the products associated o D 6 with it at any time without obligation to notify any person or organisation of such changes In no event will the A manufacturer be liable for direct indirect special incidental or consequential damages arising out of the use or 2 ee 949 inability to use this product or documentation even if advised of the possibility of such damages This document Ai l A gt contains materials protected by copyright All rights are reserved No part of this manual may be reproduced or l al transmitted in any form by any means or for any purpose without expressed written consent of its authors Product 3 CLK aa DATA H al O _ 4 names appearing in this document are mentioned for identi
13. fication purchases only All trademarks product names O eee ee 8 or brand names appearing in this document are registered property of their respective owners n al al i of S 2 N Contents B 1 Introduction 1 2 Technical Specification 1 3 Number Types 2 Operation 2 1 Registration a EEEE 2 2 Command Message Format 2 3 Master Number Setup o 2 4 Allowing Master Control for All Users 2 2 5 Adding a User Number 2 2 6 Removing a User Number 2 7 Viewing the Valid Number List 2 8 Finding a Number in the Memory 2 9 Clearing All Numbers and Settings 2 10 Result Acknowledgement Message 3 Relay Operation Access Control 3 1 Enabling Any Number and Disabling Open on Call 3 2 Select the Call Output Relay 3 3 Call Reject 3 4 Connecting a Call 3 5 DTMF Keypad Control SO SO SO 0 C0 CO CO OONNNAARaAAaAaK WW W W 3 6 Relay Status Message oe Relay Activation Mode yy i 3 8 Relay Activation Time S 6 3 9 De activating Voicemail 10 3 10 ON amp OFF Commands 10 w 3 11 OPEN and CLOSE Commands 11 D 4 Dialling Commands 11 D Q 4i Dial Now 11 N 22 4 4 Changing the Maximum Ring Time 11 4 5 Changing the Maximum Call Time 11 a 4 6 Changing the Maximum Silence Time 11 W I 5 Setup 12 5 5 1 SIM Keep Alive Text 12 5 2 Signal Strength Indicator 12 o 5 3 Power Up Reset Text Message 12 a 6 Installation 13 6 1 Power Connection 13 a 6 2 Output Connection 13 S 10uF ioon 6 3 Antenna Connection 14 6 4 Mounting 14 K 6 5 Sch
14. he x key on the telephone keypad Similarly the hash relay is activated by pressing and holding the key on the keypad Once finished the user hangs up the line 3 6 Relay Status Message To determine the current status of the output relays the STATUS command is sent to the system telephone number by a master phone as follows STATUS The system will respond with a SMS text message as follows STAR RELAY OPEN GATE RELAY CLOSED The star relay is the relay operated by the DTMF x key under DTMF control also known as the CLOSE relay The is the relay operated by the key under DTMF control also known as the OPEN relay 3 7 Relay Activation Mode When a valid call is received the relay can be set to activate for a set period of time set by the RLYTIME command to activate whilst the caller is ringing or to toggle between states on each call By default the relay mode is set for timed pulsed activation To switch to toggle mode the following message is sent to the system by the master number RLYMODE TOGGLE enables toggle mode To activate the relay for however long the caller rings n b turn off voicemail RLYMODE RING relay active whilst phone rings Ring Mode To revert to timed pulsed mode the following message is sent RLYMODE PULSE relay Normally Open NO time set by RLYTIME Section 3 8 3 8 Relay Activation Time The RLYTIME command is used to adjust the time the
15. ing Any Number and Disabling Open on Call The system can be setup to allow any number to operate the relay output To enable any call the CALL command is used with the action ANY and is sent by the master phone in the following format Call any To return the system to operate from only valid user numbers the LIST action is sent with the CALL command as follows call list To disable activation of the relay by calling the following command is sent to the board the relay can still be activated by SMS text see ON OFF and OPEN CLOSE commands CALL NONE If TEXTRES is enabled the system will respond with the Operation Successful message 3 2 Select the Call Output Relay Where Open on Call is enabled see Section 3 1 an incoming call can be set to actu ate either the star or hash relays or the board can be set to alternate between each relay on every call Alternating between each relay is useful for controlling an open and close input on a roller shutter or gate controller One call opens the shutter and the next closes the shutter To select the star relay output channel the following command is sent to the board CHANNEL selects the star or CLOSE relay output To select the hash relay output channel the following command is sent to the board CHANNEL selects the hash or OPEN relay output To alternate which output a call activates the following command is sent to the board CHANNEL
16. relays are active following a call when RLYMODE is set to PULSE or when using the OPEN and CLOSE commands see section 3 x Each relay can have it s own RLYTIME time set If the relay is not specified the RLYTIME com mand set the pulse time for both relays However if the relay is soecified the pulse time for only the specified relay is set To specify the intended relay the command is modified as follows RLYTIME sets the hash relay pulse time RLYTIME sets the star relay pulse time RLYTIME sets the pulse time for both relays By default the relay time is set fo 3s The time can be set from 1s to 999 seconds or 1 to 999 minutes using this command To change the activation time the master number sends a SMS text message as follows RLYTIME seconds RLYTIME minutesm
17. ster number has been successfully setup Calling the board s telephone number with the master phone will now activate the relay Once one master number has been setup further masters Up to 512 can be setup by this and subsequent master phones without the jumper fitted Using the same message Using the PIN for Master Setup The Master Number can also be set up using the PIN This is only possible for the first master number that is added to the system Subsequent masters must be added by a master using the MASTER command The PIN is the last 5 characters of the IMEI number written on the QUECTEL GSM module sticker The command is sent as follows Master 07000000000 37212 for module with IMEI 355073034237212 2 4 Allowing Master Control for all Users To enable any user to control master commands such as adding and removing numbers the MUSER command is sent to the board by a master number as follows MUSER ENABLE MUSER DISABLE Allows any valid user number to modify settings Only master numbers can modify settings By default MUSER is set to disable full access for all users N B Only master numbers can add other master numbers despite this setting 2 5 Adding a User Number Any telephone number of at least 5 digits where caller ID is available is valid The system only compares the last 8 digits if present of any calling number against the numbers stored in memory Therefore it is not
18. t to register on the SIM card on it s home network Once registration has occurred LED1 will change from flashing approximately once every second to a momentary flash once every two seconds If the LEDI continues to flash once every second for some time the system cannot register the SIM on the network The system will restart should this occur If the problem persists check the antenna and strength of signal in your area validation of the SIM card Observe anti static precautions when inserting the SIM The second LED LED2 found by the 5 pin header is used to display the result of a com mand The LED will flash twice to acknowledge the successful receipt of a command and will light continuously for 2s to show the instruction has failed It also illuminates during any call valid or invalid and lights continuously when a signal cannot be found network de pendent 2 2 Command Message Format To operate the system a master GSM phone is used to send SMS text messages to the system telephone number All message follow a similar format as follows COMMAND lt space gt action eg Master 07000000000 The command see Section 7 is always written first followed by a space and the action required Although not necessary if is useful to include a full stop immediately after the action as some mobile phones can enter superfluous characters at the end of a message which can invalidate the message The message is not CASE sensitive 2 3 Master
19. they were added with the primary mas ter not displayed e g 33333333 22222222 11111111 00000000 2 8 Finding a Number in the Memory When a large number of numbers are stored in the memory using the LIST command can be impractical To find whether an individual number is stored in the memory the master user sends the following command fo the board 3 11 OPEN and CLOSE Commands The OPEN star relay and CLOSE hash relay can be operated by SMS text message using the OPEN and CLOSE commands When using these commands the system behaves like it has received a call and follows the RLYTIME and RLYMODE not Ring Mode configuration OPEN activates the hash relay for RLYTIME or indefinitely if RLYMODE TOGGLE CLOSE activates the hash relay for RLYTIME or indefinitely if RLYMODE TOGGLE The opposing relay is always deactivated i e when OPEN is sent the CLOSE relay is deacti vated 4 Dialling Commands 4 1 Dial Now If necessary the system can make a call at any time This is achieved using the DIAL com mand The call observes the RTIME CTIME and SILENCE time settings DIAL lt space gt number make an ad hoc call to the specified number e g dial01517283167 The call will end when the other party hangs up or the CTIME or SILENCE time limit is reached 4 2 Changing the Maximum Ring Time The maximum time for which the system will attempt dialling is set using the RTIME com mand The default time limit is 60s
20. umber and dialed If the user is able to put the SIM in a mobile phone then we recommend doing this before it is Used in the board If this is not possible the user may use the DIAL command to send the code to the network The MASTER user sends the following text to the board DIAL 004 3 10 ON amp OFF Commands The ON command is used to activate the relay with a SMS text message The OFF com mand deactivate the relay whether activated by the ON command ora call By default the ON command activates the opposite relay to that selected by the CHANNEL com mand see Section 3 2 This allows calls to control one relay and texts to control the other However either relay can be operated at any time by the ON command by specifying the relay as follows ON operates the other relay to that set by the CHANNEL command ON operates the star CLOSE relay ON operates the hash OPEN relay When the ON command is sent without any additional instructions the relay is activated indefinitely When sent with a value and m inutes or s econds parameter the relay acti vates for a set period of time The maximum number length is three characters therefore the timer is limited to 999 sec onds or 999 minutes If the m ors parameter is not sent then the timer value is read as the number of seconds e g on activates relay indefinitely ON 10 10 second activation time s parameter optional ON 250s activates the hash relay for 250 se
Download Pdf Manuals
Related Search
Related Contents
Pulsotronic Digital Y Separator Manual Ergotron WorkFit PD Dual Monitor Kit ごみの出し方・分別ガイド - www2.city.mitsuke.niigata.jp`s HomePage Português TRUSURROUND, SRS, e o símbolo são marcas Fatal1ty Z77 Professional-M Series_QIG_ASR.indd GMS 100 M Professional Bedienungsanleitung - Amica International Copyright © All rights reserved.