Home

User Manual of Tissue Box Camera

image

Contents

1. Please use it under bright environment Keep the device vertical and stable so that it can get the best recording The device use built in high capacity polymer lithium ion battery having memory effect so in the first 5 times please charge it fully when it is power off So that can activate the maximum capacity and get the standard time The time of PC recognizing the device is different according to its different system and configuration so please do not operate during recognizing If the device can t be recognized please check your computer s operation system device drivers USB port and the USB cable is normal and then connect the hardware again
2. the device to computer via USB cable or charge it with charger Then the light blinks slowly which means it is on charge The green light will keep on when the device is fully charged Attention 1 When power is low the battery will switch to protected mode so you can t turn it on and you need to charge it 2 Make sure you push the power button to ON position otherwise the device can t be recharged Playback After finishing record connect the camera to the computer via USB cable Find the file in removable disk then you can play them Before connecting please make sure the computer has been installed the related playing software Note when you remove the USB cable from the device please press the surrounding of USB port with medium strength as the following indicator picture Setting Date and Time 1 You can set the time through the following way oO fh o1 aa rtwHANnr Create a file named TAG txt edit the file as the following format First line date Second line 2010 12 12 year month date Third line 12 12 12 hour minute second Copy the file to root disk of the camera the time of camera will be updated when you pull it out and restart it again Attention If the power is low during recording the device will save the video automatically then turn off The effective induction distance is about 18 meters After every video file a new file will come up during recording
3. User Manual of Tissue Box Camera Product Accessories e Tissue box camera e Remote controller e USB cable e Adapter e Manual CD Picture amp Buttons Record Save T Indicator light Reset Power on off Valve gate USB port 1 Cover 2 USB port 3 Power on off button 4 Record Save 5 Indicator light 6 Camera 7 MIC 8 Record Save remote Technical Data This device is a new type of remote control camera with internal memory which can be used for digital video recording also as the USB flash disk It is characterized by ease of use remarkable concealment and good audio effect 1 Main function Recording video and audio manually amp by remote control tissue box USB flash disk 2 Video AVI 720 480 3 Internal memory 2GB 4GB 8GB 4 USB interface 2 0 Hs 5 Charging time 7 8 hours 6 Battery use time built in Li battery 6 hours 7 Operation system No need for driver installation if the operating system is Windows ME 2000 XP Vista or above windows98 is excepted Operation Switch on Push the power button to ON after pulling open the tissue box and then close it At this time camera comes to standby mode Attention to save power if you no need to use it please push power button to OFF position for saving power Recording video and audio manually Under standby mode slid the cover out Long press the record button then the green
4. light Keeps on for 2sec and off after blinking 3 times which means it starts to record press the same button again so the video will be save and the device back to standby mode Attention the longest recording time is 30 minutes If the memory is full the device will save the video then turn off automatically during camera is recording Recording video and audio by remote control Under standby mode long press the record button the green light keeps on for 2sec and off after blinking 3 times which means it starts to record press the same button again so the video will be save and the device back to standby mode Reset Under incorrect operation or an uncertain reason the device may stop working at this time press the Reset button to reset and then the device is under power off mode Attention when resetting while it is recording the files cannot be saved Switch off Under standby or recording mode push the power button to OFF position to turns off the device You could also press the reset key to turn it off Attention 1 In order to save the set video time only press the Remote Control to power off so that the video time will be saved If power off by the power on off button the video time will be needed to be set the next time 2 The video will be lost if you push the power button to turn off the device during recording Charging Push the power button to ON position before connecting

Download Pdf Manuals

image

Related Search

Related Contents

User Manual Oracle FLEXCUBE Direct Banking Retail Term Deposit  1761-6.5, DeviceNet Interface User Manual  Lista de precios    Filter Wheel  Istruzioni per l'uso Instructions for use Betriebsanleitung Mode    取扱説明書  MANUAL SERVICO FERRO PLAV2-R00a.p65  

Copyright © All rights reserved.
Failed to retrieve file