Home
Notifier – NFN Web Server Manual
Contents
1. 0000 NFN Web Server PC Board Figure 2 8 1 Ethernet Connection 2 9 PC TO PC CONNECTION This connects the NFN Web Server to a PC that has one of the following programming utilities installed on it e Serial Configuration Tool P N NWS SW e Veri Fire M Tools P N VERIFIRE TCD This connection is used when configuring the Web Server To EIA 232 port on E PC or laptop To EIA 232 port on NEN Web Server PC Board 0000 Figure 2 9 1 PC to PC Serial Connection NOTES Cable must be A supplied by customer and must be a null modem cable NEN Web Server User s Manual PN 51990 A2 12 02 03 www PDF Zoo com NOTES 20 NEN Web Server User s Manual PN 51990 A2 12 02 03 www PDF Zoo com SECTION THREE NFN WEB SERVER CONFIGURATION 3 1 NEN WEB SERVER SERIAL CONFIGURATION TOOL INSTALLATION There are two ways to configure the NFN Web Server use the NWS configuration tool supplied on CD ROM or use Veri FireTM Tools the NOTI FIRE NET programming utility The Serial Configuration Tool software is supplied on CD ROM To install the application onto the PC or laptop follow these steps 1 Insert the CD ROM into the CD ROM drive 2 If the CD does not automatically run the installation setup from Windows Explorer or the Run command execute
2. surge suppressor e DB9 to NUP Cable P N 75554 connects the NEN Web Server to an NCM W F e Modem cable connects the Web Server to a modem see Figure 2 7 1 e NUP to 24V power cable P N 75583 provides power for the NCM W F not required for standalone mode HDD Power connector P N 75581 used for 24VDC to 5VDC power connection e Serial Configuration Tool software supplied on CD ROM P N NWS SW e NFN Web Server Power Supply Mounting Plate P N 18541 Network Interface sold separately e NCM W F Network Communications Module used to facilitate network communication between the NEN Web Server and NOTI FIRE NET NOTE The NCM W F is not required when directly connecting an NFN Web Server to an NFS 640 or NFS 3030 when either acts as a standalone panel Cabinetry Installation Hardware sold separately e CAB 3 CAB 4 series cabinet e CHS 4L chassis Other Required Equipment NOTE These items must be supplied by the customer e PC to PC connector cable connects the NEN Web Server to a PC or laptop e PC or notebook used to configure the NEN Web Server NEN Web Server User s Manual PN 51990 A2 12 02 03 13 www PDF Zoo com 2 2 INSTALLATION OVERVIEW Use the following checklist as a guideline for assembling the hardware and making necessary cable connections The sections that follow provide details on making these connections Perteesmewemew ewm Ll ro pve cese Pr ma a oma LT formen t Figure 2
3. 49 NOTES 50 NEN Web Server User s Manual PN 51990 A2 12 02 03 www PDF Zoo com Limited Warranty NOTIFIER warrants its products to be free from defects in materials and workmanship for eighteen 18 months from the date of manufacture under normal use and service Products are date stamped at time of manufacture The sole and exclusive obligation of NOTIFIER is to repair or replace at its option free of charge for parts and labor any part which is defective in materials or workmanship under normal use and service For products not under NOTIFIER manufacturing date stamp control the warranty is eighteen 18 months from date of original purchase by NOTIFIER s distributor unless the installation instructions or catalog sets forth a shorter period in which case the shorter period shall apply This warranty is void if the product is altered repaired or serviced by anyone other than NOTIFIER or its authorized distributors or if there is a failure to maintain the products and systems in which they operate in a proper and workable manner In case of defect secure a Return Material Authorization form from our customer service department Return product transportation prepaid to NOTIFIER 12 Clintonville Rd Northford Connecticut 06472 1653 This writing constitutes the only warranty made by NOTIFIER with respect to its products NOTIFIER does not represent that its products will prevent any loss by fire or otherwise or
4. E Annunciator LJ NOOS AFP 200 NOO7 NFS 640 NOO8 NFS 640 NO38 NFS 640 NO78 NCA NOB2 NFS 3030 N087 NWS LOCAL E Notifier Auto Point Detect AFP400 The Auto Point Detect feature does not function for the AFP 400 series of panel In order to create a list Multiple Event List of points for an AFP 400 panel you must go to the site and physically create an event for each point you EJ Version Information want the NWS to add to its list of points for that panel I NUP Port Statistics Summary NOO1 AM2020 Please consult the NWS manual for further details Auto Pont Detect P Trusted sites Figure 4 3 1 2 Auto Point Detect AFP400 Message A Louisville Design Center Microsoft Internet Explorer File Edit View Favorites Tools Help cc e MEAR MET CC IM rcu Back Forward Stop Refresh Home Search Favorites History Mail Print Edit Discuss Address a http 179 12 86 119 ee Links Louisville Design Center NWS Explorer Object System Administration Auto Point Detect For All Panels NWS Home Page Auto Point D O Notifier System Administration Multiple Event List Version Information O NUP Port Statistics Summary E Server is discovering active points C 0 complete O Cancel auto point detect during auto point d ete El Auto Point Detect For All Panels pie Event List u Version Information E Server is discovering active points O 25 complete E Cancel auto di
5. O search i Favoritds Address htip 179 12 86 119 MENU System Administration a Auto Point Detect For E Mail Notification O E Mail Configuration E Mail Profile 1 E Mail addresses E Mail Profiles 3 DlProfite 1 Disable Profile 7 emailt yourdomain com Profile 2 Li 1 E Profile 3 email2 yourdomain com CHESS email3 yourdomain com O Profile 5 EJ Profile 6 Jemail4 yourdomain com O Profile 7 D Profile e email yourdomain com O Profile 9 O Profile 10 7 System Settings Save Profile No J Password Configuratior O Authorization Log N001 AM2020 v N007 NFS 640 Ra Monitoring Profiles Node Mapping a Multiple Event List 7 Version Information NUP Port Statistics Sumr N082 NFS 3030 E N001 AM2020 E N007 NFS 640 N087 NWS NOO8 NFS 640 None y E N038 NFS 640 None Y None S Ef El z amp Profie 1 Internet Figure 4 3 2 2 E mail Profile Configuration NEN Web Server User s Manual PN 51990 A2 12 02 03 www PDF Zoo com 33 CUSTOM MESSAGES The administrator can define a 50 character max custom message corresponding to the event types These messages will be included in the body of any e mails sent to specified recipients Louisville Des
6. 6o Links Louisville Design Center NWS Explorer Object Node 82 Loop 1 Module LO1M013 MENU E Monitoring Protiles Node Mapping O Password Configuration Authorization Log State ormal Multiple Event List Status Automatic Version Information Trouble Status lormal E NUP Port Statistics Summary Custom Label Module LO1MO13 N001 AM2020 Extended Label N007 NFS 640 N038 NFS 640 Module Type MONITOR N077 NFS 640 Type Code Label MONITOR PERA Flashscan Type MINI DUAL MONITOR E N082 NFS 3030 CERE aes I By Event 2 1 20 20 2020 20 20 202020 Lo1Mo13 SontralzBy O L01M017 I c L01M077 0 SETHINSS E Panel Modules Local Mode Participation E Zones CustomActionMessage Logic Zones Release Zones Trouble Zones E Custom Action Messages Occupancy Schedule History Alarm History E 4 E Lo1M013 118 Internet Figure 4 7 3 Module Properties Sample Screen NEN Web Server User s Manual PN 51990 A2 12 02 03 www PDF Zoo com 46 lle Design Center Microsoft Internet Explorer Ele Edit view Favorites Tools Help amp Bak v gt O A A search Favorites CHristory y S E El El Address http 179 12 86 119 y os Links Louisville Design Center NWS Explorer Object Node 38 Loop 1 Detector LO1D013 MENU PROPER L Monitoring Protiles aj P Node Mapping State ormal O Password Configuration Status O Authorization Log 3 3 Trouble Stat
7. admin logged on at 14 18 26 FRI JUNE 20 2003 25 admin logged on at 14 09 34 FRI JUNE 20 2003 v 24 admin logged on at 13 49 02 FRI JUNE 20 2003 gt 23 admin logged on at 13 48 35 FRI JUNE 20 2003 Authorization Log 2 Internet E N007 NFS 640 Figure 4 3 7 1 Authorization Log NEN Web Server User s Manual PN 51990 A2 12 02 03 www PDF Zoo com 39 4 4 MULTIPLE EVENT LisT The Multiple Event List screen displays an event count sorted by event type Below is an example showing multiple Fire Alarms and Troubles To view event details click on a specific event typefrom the menu list a Louisville Design Center Microsoft Internet Explorer Ele Edit view Favorites Tools Help S Back v v A Bsearch Favorites CBristory By amp EJ aw ees Louisville Design Center NWS Explorer Object Multiple Event List O NWS Home Page Fire Alarm C Notifier Trouble E System Administrator Supervisory EI Au Point Dos Fo A Panel 5 A leen Prealarm B O System Settings cir Disabled Point Node Mapping Other Events DD zz EJ Password Configuration Total Events O Authorization Log Multiple Event List O Version Information O NUP Port Statistics Summary N001 AM2020 N007 NFS 640 NOO8 NFS 640 N038 NFS 640 N082 NFS 3030 N087 NWS LOCAL Rim ni E Multiple Event List 82 Internet Figure 4 4 1 Event List Summary 40 NEN Web Server
8. EC EU in 40 Figure 4 4 2 Multiple Event Fast Details uso eine tree tee cused eee ann eee ate go ont 41 4 5 VERSION INFORMATION yc turre FF nhan He satia acre 42 Figure 4 5 1 Version Information ie ee eH ettet ERE CH epa PUER andes 42 4 6 NUP PORT Ae RP DYDD Wn DN SOUnNNYDDEYOYDDUuTYnAbnnFOAOTDDYRSDDFONDHAUDNNUEDFDDANDADO DDU d Yn 43 Figure 4 6 1 NUP Port Statisctics Overview sees enne ennetee teen A eteennes 43 Figure 4 6 2 Local Node NUP Port St tisctiCs osier iii nece tmt rte en ae rut 43 4 7 SCREEN DETAILS AND OPTIONS FOR SPECIFIC PANELS eere eee eene einen nnno natn sins tn sns tn sins ta sonent stan 44 Figure 4 7 1 Panel Properties Display Sample sss enne nenne nennen 44 Figure 4 7 2 Loop Properties Sample Screen sess nennen treten eere 45 Figure 4 7 3 Module Properties Sample Screen sse rennen nc nora een nne nene 45 Figure 4 7 4 Detector Properties Sample Screen ooooccncniccnonononooncnnncononnnonnconncon cnn ncon on ncnn non corno nennen ren enne 46 NEN Web Server User s Manual PN 51990 A2 12 02 03 5 www PDF Zoo com NOTES 6 NEN Web Server User s Manual PN 51990 A2 12 02 03 www PDF Zoo com SECTION ONE NFN WEB SERVER FEATURES 1 1 Propuct DESCRIPTION The NOTI FIRE NET Web Server is a web based device that acts as an HTML server that allows remote access to the NOTI FIRE NET network via the Internet or a
9. Louisville Design Center NWS Explorer MENU PROPERTY JE NWS Home Page Mapping Profile O Notifier Node 1 El System Administration Auto Point Detect For All Pa Node 2 E Mail Notification Ol System Settings Node 3 Monitoring Profiles Node 4 E Node Mapping Nodes 001 030 Node 5 O Nodes 031 060 Node 6 Node Mapping E Nodes 061 090 Links x Nodes 091 120 Node 7 Nodes 121 150 Y Node 8 O Nodes 151 180 O Nodes 181 210 Node 9 O Nodes 211 240 d Password Configuration Nase au O Authorization Log Node 11 Multiple Event List Version Information Node 12 O NUP Port Statistics Summary Node 13 NO01 AM2020 N007 NFS 640 Node 14 NO08 NFS 640 NO38 NFS 640 Node 15 NO82 NFS 3030 meu w Node 17 ld y Node iR Object System Administration Node Mapping Nodes 001 030 Unmapped y Unmapped y Unmapped y Unmapped y Unmapped y y Unmapped y Unmapped Ac Unmapped Unmapped Unmapped y Unmapped y Unmapped y Unmapped y Unmapped y LL ui Inmanned y amp Nodes 001 030 amp Internet Figure 4 3 5 1 Node Mapping Four NODE STATUS VALUES Online The node was auto detected by the NFN Web Browser but it will not show up in the Menu at the left nor will events be displayed until it is mapped Offline There is no device detected at that node address No events will be reported Mapped If the node is online it will show up in the Menu and events will be displayed in the bro
10. Point Detect AFP1010 AM2020 panels E Mail Notification LJ System Settings Monitoring Profiles Node Mapping E Password Configuration O Authorization Log Multiple Event List O Version Information CE NUP Port Statistics Summary ted automatically the NWS refreshes Noo1 AM2020 Please consult the NWS manual for further details x F N007 NFS 640 NOTE Only administrators ninos NFS 640 Press Perform Auto Point Detect if you are sure you wish to perform this function ND38 NFS 640 1 N053 NCA have security access to the auto nn Perform Auto Point Datect N082 NFS 3030 detect feature nen N087 NWS LOCAL N087 NWS LOCAL amp Auto Point Detect AFP1010 AM2020 panels 9 Internet Figure 4 3 1 1 Auto Detect Points 30 NFN Web Server User s Manual PN 51990 A2 12 02 03 www PDF Zoo com The Auto Point Detect feature does not function for the AFP 300 400 panel as seen on the screen message shown below 4 Louisville Design Center Microsoft Internet Explorer lal x Ele Edit View Favorites Tools Help Back v 9 A A Qsearch iFavorites Meda B By S Address http 101 101 101 101 8888 y s Links gt Louisville Design Center NWS Explorer Object Node 2 Auto Point Detect MENU PROPERTY VALUE E NWS Home Page System Administration El NOO2 AFP 300 400 Auto Point Detect Panel Modules Bell Circuits Zones E Release Zones E Special Function Zones
11. WEB SERVER Via NCM NOTE THIS OPTION IS ONLY USED WHEN IT IS NECESSARY TO RE CONFIGURE THE WEB SERVER SETTINGS 1 Select the COM port being used 2 Specify the node number being used for the NFN Web Server 3 Click OK to finish configuration If the NFN Web Server does not yet have a node number the PC must be connected directly to the Web Server first to give it one NOTE To configure the NWS via an NCM you must have a NUP to DB9 cable P N 75554 After selecting OK the configuration tool will attempt to communicate with the Web Server In the case where communications can be established it may take up to 10 seconds to finish the initial communications however if communications can not be established because nothing is connected to the serial port it will take up to 30 seconds before the Configuration Tool displays an error message NEN Web Server User s Manual PN 51990 A2 12 02 03 21 www PDF Zoo com After communication has been established the following window will appear NWS Configuration x NCM Configuration IP Configuration Node es IP for connection to NWS 101 101 101 3 I Port amp Threshold HIGH IP Assigned to PPP modem clients 101 101 101 4 Port B Threshold HIGH IP for routing back to internet 101 101 101 5 Style 7 no Subnet Mask 255 255 255 0 Figure 3 2 2 NFN Web Server Configuration There are eight settings pertaining to the network setup of the Web Server four of these
12. a shortcut to the link list at the left of the NFN Web Browser window This link can be to a graphic image of the network site or a company homepage Site Link Name This is the name that will be displayed in the browser header when the Site Link address is accessed NOTE Only alphanumeric characters are supported for the Site Settings fields with the exception of the colon forward slash and period GENERAL SETTINGS Non Admin User Access This setting defines whether or not operators will have access to the NFN Web Server Network Update Select Yes to have the NFN Web Server auto detect points daily Network Update Time If the Web Server is configured to auto detect points daily this field is used to select the time you want the Web Server to perform this action Trouble Reminder If there is an active trouble on the network every 24 hours at 11 00 AM a trouble reminder message will be generated across the network Event Refresh Time This field is used to specify a refresh rate between 3 and 90 seconds for the Multiple Event List The NWS will automatically refresh itself at the specified interval Any new system event will be displayed in the Multiple Event List To disable this feature set the time to 0 Unacknowledged Beep Check this option to enable an audible reminder of unacknowledged events When this is checked the Web Server will beep at 3 second intervals and will continue until no unacknowledged events are shown in
13. as displayed on the previous screen is the node address of the NFN Web Server To change this number using Veri FireTM Tools select Panel Node Address Change from the menu bar on the main screen d NTSRunTime gt VeriFire Tools BA Panel Main Services Spreadsheets amp E2 New Edit Session W Save Node Data E Save Node Data As amp Close Service A Nodes on Network Login El Node Password Change FA Node Address Change D Exit VeriFire Tools Figure 3 4 8 Changing the Node Address Type in the new node address and click Update to apply the changes or Cancel to exit without changing the address T Node Address Change x Currently Logged In Node 87 New Node Address Update Cancel Figure 3 4 9 Changing the Node Address 28 NEN Web Server User s Manual PN 51990 A2 12 02 03 www PDF Zoo com SECTION FOUR NFN WEB SERVER 4 1 NEN WEB SERVER SECURITY The user default ID is users and the user default pass word is 11111 The Admin default ID is admin and the admin default password is 00000 These passwords should be modified as soon as possible to retain system security When the application is started a user or administrator must log in to have access to functions assigned to him her by the system administrator To log in enter your User ID and password then click OK You can choose to Save this password in your password list this option will
14. can be configured for email notification according to various event types The general appearance of the email notification message will vary depending on the email application used individual PC font settings and other factors A sample message however can be seen in Figure 4 3 2 4 FIRE ALARM N082L010012 i B xl Ele Edit view Tools Message Help Gereply ff Reply All GE Forward amp X a w From Louisville Design Center Date Friday October 31 2003 11 31 AM To ahopperton notifier is net Subject FIRE ALARM NO82L01D012 he Site Name denotes here the NWS is located he Site Name is onfigurable under System dministration System The Fire Alarm Web Server automatically generated the following event message Site Name Louisville Design Center The information under Event displays detailed Event event information in the same format as that of the panel or annunciator FIRE ALARM ROOM 222 2ND FLOOR Zone Z001 Z001 SMOKE ION 11 31 304 FRI OCT 31 2003 NO82L010012 Custam Message This is the custom message Report to node site immediately that was defined for this event type Your e mail address has been listed in the web server to be notified in the case of an event of the type listed above Please contact your system administrator if you have been inadvertently notified Figure 4 3 2 4 Sample Email Message 34 NEN Web Server User s Manu
15. excellent working order ongoing maintenance is required per the manufacturer s recommendations and UL and NFPA stan dards At a minimum the requirements of Chapter 7 of NFPA 72 shall be followed Environments with large amounts of dust dirt or high air velocity require more frequent mainte nance A maintenance agreement should be arranged through the local manufacturer s representative Maintenance should be scheduled monthly or as required by National and or local fire codes and should be performed by authorized pro fessional fire alarm installers only Adequate written records of all inspections should be kept Precau L 4 2002 p65 NEN Web Server User s Manual PN 51990 A2 12 02 03 Installation Precautions Adherence to the following will aid in problem free installation with long term reliability WARNING Several different sources of power can be con nected to the fire alarm control panel Disconnect all sources of power before servicing Control unit and associated equip ment may be damaged by removing and or inserting cards modules or interconnecting cables while the unit is energized Do not attempt to install service or operate this unit until this manual is read and understood CAUTION System Reacceptance Test after Software Changes To ensure proper system operation this product must be tested in accordance with NFPA 72 Chapter 7 after any programming operation or change in site specific soft ware Reacceptance
16. follow these steps Insert the CD ROM into the CD ROM drive 2 From Windows Explorer or the Run command execute setup exe from the root directory of the CD ROM 3 This will execute the install application Follow the directions on screen to install VerieFire Tools 4 Once it is installed it can be launched from the Start menu by selecting Programs VeriFire Tools VeriFire Tools NOTE The NFN Web Server is A compatible with VerieFire Tools version 3 00 or later Veri Fire Tools can communicate with the Web Server in one of two ways 1 Direct communication by connecting VerieFire s PC to the web server s serial port this connection using DB9 DB9 is used for the Web Server s initial setup to be able to communicate over the NEN network 2 Communication over the NEN network by connecting VerieFire s PC to the second NUP port of an NCM that is on the same network as the Web Server THE SERIAL PORT CONFIGURATION UTILITY To activate communications between the PC and the NEN Web Server use the Serial Port Configuration Utility accessed from the Start menu by selecting Start Programs VeriFire Tools Serial Port Configuration Utility The NUP Serial Port Auto Configuration dialog will appear seen in Figure 3 3 1 PC DIRECTLY CONNECTED TO NFN WEB SERVER For a PC directly connected to the NFN Web Server click on the Auto Configuration button to establish communica tions When finished exit by clicking on the x butto
17. is an SMTP server setting Leave this field blank unless your network administrator indicates otherwise A Louisville Design Center Microsoft Internet Explorer BEE File Edit View Favorites Tools Help Heak v gt O Dp A search gravorites 4 Ay 3 Ed v 2 Links gt Louisville Design Center NWS Explorer Object System Administration E Mail Configuration MENU O NWS Home Page ye nas BU Outgoing Mail IP Address SMTP fori D E System Administration E Auto Point Detect AFP1010 AM202 Mail User ONERE E E Mail Notification E E Mail Configuration E Mail Profiles System Settings O Monitoring Profiles Node Mapping O Password Configuration O Authorization Log Multiple Event List E Version Information O NUP Port Statistics Summary N001 AM2020 El N002 AFP 300 400 E N007 NFS 640 NOD8 NFS 640 NO38 NFS 640 El N078 NCA El N082 NFS 3030 N087 NWS LOCAL E E Mail Configuration amp Internet Figure 4 3 2 1 E mail Configuration E Ma1L NOTIFICATION FEATURES The following lists some of the benefits that the e mail notification feature provides e Ten Profiles e Send up to 50 e mails in response to any system event e Quickly Enable and Disable E mail feature e Create your own custom messages that will be included with the e mailed system event 32 NEN Web Server User s Manual PN 51990 A2 12 02 03 www PDF Zoo com CONFIGURING E MAIL PROFILES Profiles define the e mai
18. pertain to parameters for use in establishing a NOTI FIRE NET communications link through an NCM and four of these pertain to allowing a browser to establish a connection NCM CONFIGURATION The Node field is the node number you will use in connecting to NOTI FIRE NET If the configuration tool is connected through an NCM the node number may not be changed to change the node number exit the configuration tool by pressing Cancel then connect the PC directly to the Web Server and run the service tool again The threshold and style 7 settings are standard NCM settings refer to the NCM documentation for an explanation of these fields IP CONFIGURATION These four settings configure various IP parameters for use in connecting a browser IP FOR CONNECTION TO NWS sets the actual IP address where the Web Server will be located The user will type this address into a browser in order to establish a connection with the Web Server Note that if the Web Server is to be used on the internet you may need to independently set up a router and or firewall so the internet based applica tions can locate and access the Web Server Contact your MIS department for details To actually connect to the Web Server requires use of TCP IP port 8888 for example if the NWS is located at 10 4 2 1 one would type http 10 4 2 1 8888 into the browser window to connect to the Web Server IP ASSIGNED TO PPP modem CLIENTS sets the IP that the Web Server
19. rete entere te eoe eis eee no 26 Figure 3 4 5 Configuring the Web Server Connection Session sese nennen 26 Figure 3 4 6 VerieFire Tools System Password eese eene nen nennen rennen 27 Figure 3 4 7 Selecting the Connection Type essssssssseseeeeeeeneeee n enne eere rennen rennen nne nennen 27 Figure 3 4 8 Changing the Node Address imei 8er ana sn 28 Figure 3 4 9 Changing the Node Address sess nennen rennen cria rra coins 28 4 NEN Web Server User s Manual PN 51990 A2 12 02 03 www PDF Zoo com SECTION FOUR NFN WEB SERVER OPERATION cscsscsssssssssssssssessssssssesssssessessessesses 29 4 1 NEN WER SERVER SECURITY anne org 29 Figure 4 1 1 NEN Web Server Login Dialog eese eene nennen eere neret 29 42 THE BROWSER INTERFAUR idit tii titor eta teen nei DE env Mace teaser 29 Figure 42 1 NWS Home Page is ua aii ette ee reet e a e e erc tede diede etd 29 4 3 SYSTEM DMINISTRATION i ee seteepeesk cu puniat uns us uade u cose 30 4 3 1 Auto Detect Points on all Panels sessesuseonenesnenssnensonennenensenennenennenennenennensnsnsenssnenennenennenennenennenennenennenene 30 Figure 4 3 1 1 Auto Detect Points tecti e tp Rie Rep a 30 Figure 4 3 1 2 Auto Point Detect AFP400 Message coooccoccconcooccononancnnonnonncnononnocnnonnncononnn cnn non non ron nenne teens 31 Figure 4 3 1 3 Auto Detect Screen isie ruin ee eie reper eg Pee ME E
20. that its products will in all cases provide the protection for which they are installed or intended Buyer acknowledges that NOTIFIER is not an insurer and assumes no risk for loss or damages or the cost of any inconvenience transportation damage misuse abuse accident or similar incident NOTIFIER GIVES NO WARRANTY EXPRESSED OR IMPLIED OF MERCHANTABILITY FITNESS FOR ANY PARTICULAR PURPOSE OR OTHERWISE WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF UNDER NO CIRCUMSTANCES SHALL NOTIFIER BE LIABLE FOR ANY LOSS OF OR DAMAGE TO PROPERTY DIRECT INCIDENTAL OR CONSEQUENTIAL ARISING OUT OF THE USE OF OR INABILITY TO USE NOTIFIER PRODUCTS FURTHERMORE NOTIFIER SHALL NOT BE LIABLE FOR ANY PERSONAL INJURY OR DEATH WHICH MAY ARISE IN THE COURSE OF OR AS A RESULT OF PERSONAL COMMERCIAL OR INDUSTRIAL USE OF ITS PRODUCTS This warranty replaces all previous warranties and is the only warranty made by NOTIFIER No increase or alteration written or verbal of the obligation of this warranty is authorized NOTIFIER is a registered trademark NEN Web Server User s Manual PN 51990 A2 12 02 03 www PDF Zoo com 51 NOTIFIER World Headquarters NOTIFIER isa Honeywell company 12 Clintonville Rd Northford CT 06472 1653 USA 203 484 7161 fax 203 484 7118 www notifier com ISO 9001 CERTIFIED ENGINEERING amp MANUFACTURING 52 NEN Web Server User s Manual PN 51990 A2 12 02 03 www PDF Zoo com
21. the Multiple Events List NCM SETTINGS Node Address The node where the NCM is located on the NOTI FIRE NET network Channel A B Threshold Threshold settings are used according to the amount of network noise present changing the threshold settings will initialize the NCM board itself Style 7 Select Yes if style 7 is being used NEN Web Server User s Manual PN 51990 A2 12 02 03 35 www PDF Zoo com 4 3 4 MONITORING PROFILES Selecting System Administration Monitoring Profiles allows you to select the event types to be displayed in the NFN Web Browser Select No to disable NFN Web Browser viewing of the specified event type The default value for all event types is Yes z Louisville Design Center Microsoft Internet Explorer File Edit View Favorites Tools Help Back y gt v O A Qsearch s Favorites CHristory Ev S E 8 i Address amp http 179 12 86 119 y ll Links Louisville Design Center NWS Explorer Object System Administration Monitoring Profiles MENU C NWS Home Page O Notifier E System Administration O Auto Point Detect For All Panels O la E Mail Notification System Settings Monitoring Profiles O Password Configuration O Node Mapping Authorization Log Multiple Event List E EE 9 E E 9 E Ed E E EJ Version Information NUP Port Statistics summary Noo1 AM2020 N002 AFP 300 400 NOOS AFP 200 NOO7 NFS 640 NOOS NFS 640
22. trademark of Echelon Corporation ARCNETO is a registered trademark of Datapoint Corporation Microsoft and Windows are registered trademarks of the Microsoft Corporation LEXANG is a registered trademark of GE Plastics a subsidiary of General Electric Company NEN Web Server User s Manual PN 51990 A2 12 02 03 www PDF Zoo com Precau L 4 2002 p65 3 Table of Contents SECTION ONE NFN WEB SERVER FEATURES st L CAAA LLU LLLL L L 7 iM PRODUCE DESCRIPTION kenn 7 1 2 NEN WEB SERVER SERIAL CONFIGURATION TOOL FEATURES seessesnesnennenesnnenennennennensnnnsnennennenesnsnnennennsnnenen 7 1 3 RELATED DOCUMENTATION een 7 Fable 1 3 1 Related Documentation 2 cioe tret nennen pee x even sie me na 7 1 4 STANDARDS AND SPECIFICATIONS sun nn ir elit 8 i A NEE 8 L6 SYSTEM REQUIREMENTS ea 8 1 7 SYSTEM ARCHITECTURE tie 9c en iei testa Nen Fe RUN EP Rue gwad ddd YSG S cortes e YN EYN ny 9 Figure 1 7 1 NEN Web Server Network Architecture eseesesssesseeeseeeeeennen rennen nennen trennen 9 Figure 1 7 2 NEN Web Server PPP Architecture essere eene eene nee ee nnenene ret nennen 10 Figure 1 7 3 NEN Web Server Direct Panel Interface Architecture sese 11 SECTION TWO NFN WEB SERVER HARDWARE INSTALLATION e 13 2 1 REQUIRED COMPONENTS aa 13 2 2 INSTALLATION OVERVIEW ani A Ai ia 14 Figure 2 2 1 NEN Web Server Assembly Checklist ooocoonccnocnnocncccooncononanc
23. 0 or later running on Windows 986 or Windows 2000 NOTE Netscape is not supported by the NFN Web Server application VERI FIRETM Too s SERIAL CONFIGURATION TOOL Windows 2000 operating system NOTE The NFN Web Server is compatible with VerieFire Tools version 3 00 or later DiAL UP MODEM CONNECTION e Serial modem with minimum capability of 57 6K baud 8 NEN Web Server User s Manual PN 51990 A2 12 02 03 www PDF Zoo com 1 7 SYsTEM ARCHITECTURE There are three network options for the NFN Web Server e Internet or Intranet connection Using a dial up modem e Direct panel interface to an NFS 640 or NFS 3030 The following diagrams show architecture options for a system using the NFN Web Server INTERNET INTRANET CONNECTION The NEN Web Server can uses an Internet Intranet connection via IP over Ethernet PC Browser Interface Internet or Intranet NWS NOTI FIRE NET FACP NCS UniNet NFN NION BACnet Gateway FACP NCS UniNet NFN NION BACnet Gateway Figure 1 7 1 NFN Web Server Network Architecture NEN Web Server User s Manual PN 51990 A2 12 02 03 www PDF Zoo com NEN WEB SERVER DIALUP CONNECTION The NEN Web Server can use a serial modem to communicate with a remote browser via telephone lines PC Browser Interface att supplied by customer NOTI FIRE NET network Figure 1 7 2 NFN Web Server PPP Architecture NOTES Only one user can dial into t
24. 180 O Nodes 181 210 O Nodes 211 240 O Password Configuration O Authorization Log E Multiple Event List g Version Information O NUP Port Statistics Summary N001 AM2020 N007 NFS 640 NO82 NFS 3030 How to modify a user s password e select User name to modify e type in a new password e retype password in verify field press the Modify Password button How to disable or enable a user select User name to disable or enable e press the Disable Enable button disabled Users have a next to their name I Internet vor Modify Password Disable Enable Entry Password Configuration I internet Figure 4 3 6 1 User Configuration NEN Web Server User s Manual PN 51990 A2 12 02 03 4 3 7 AUTHORIZATION LOG The Authorization Log displays a history of the last 50 users to access the NFN Web Server and includes the date and time of access IMPORTANT The history does not include failed or denied accesses The NWS does not keep a record of any failed attempts to access the web server Louisville Design Center Microsoft Internet Explorer MENU O NWS Home Page Notifier System Administration Auto Point Detect For All Pa Authorization Log H E Mail Notification 50 admin logged on at 14 32 43 MON JUNE 23 2003 E System settings 49 admin logged on at 14 23 43 MON JUNE 23 2003 Monitoring Profiles 4
25. 2 1 NFN Web Server Assembly Checklist CAUTION Different sources of power are used in conjunction with the NFN Web Server product Disconnect all sources of power before servicing This device and associated eguipment may be damaged by removing and or inserting cards modules or interconnecting cables while this unit is powered This damage may adversely affect the operation of this unit but its effect may not be readily apparent 14 NEN Web Server User s Manual PN 51990 A2 12 02 03 www PDF Zoo com 2 3 INSTALLING THE NFN WEB SERVER ASSEMBLY INTO A CAB 4 SERIES CABINET This section describes the installation of the NEN Web Server Assembly into a CAB 3 CAB 4 series cabinet NOTE Cabinet is ordered separately For installation details refer to the CAB 3 CAB 4 Series Installation Document 15330 1 The NFN Web Server power supply and PNET 1 surge suppressor are installed onto the mounting plate The Web Server board uses four standoffs the power supply uses two screws and the PNET 1 uses one M M 1 2 The mounting plate is installed ab 4 onto the CHS 4 L 3 The CHS 4 L is o oe y y ogo installed into the CAB 3 or CAB 4 series cabinet Figure 2 3 1 NFN Web Server Installation Diagram 2 4 NEN WEB SERVER PC BoARD LAYOUT The PC board layout P N 46173 is shown in Figure 2 4 1 below Descriptions of pertinent connections are described in subseguent
26. 8 admin logged on at 12 28 10 MON JUNE 23 2003 i 47 admin logged on at 12 15 31 MON JUNE 23 2003 EittiodeiMapping 46 admin logged on at 11 26 42 MON JUNE 23 2003 C Nodes 001 030 45 admin logged on at 10 50 29 MON JUNE 23 2003 C Nodes 031 060 44 admin logged on at 10 31 43 MON JUNE 23 2003 Nodes 061 090 43 admin logged on at 10 24 22 MON JUNE 23 2003 Nodes 091 120 42 admin logged on at 10 18 27 MON JUNE 23 2003 Nodes 121 150 41 admin logged on at 09 57 50 MON JUNE 23 2003 40 admin logged on at 09 51 17 MON JUNE 23 2003 O Nodes 151 180 O Nodes 181 210 39 admin logged on at 09 37 51 MON JUNE 23 2003 38 admin logged on at 15 32 01 FRI JUNE 20 2003 Nodes cL adn 37 admin logged on at 15 21 53 FRI JUNE 20 2003 JEassmordiGontouretion 36 admin logged on at 15 14 58 FRI JUNE 20 2003 EJ Authorization Log 35 admin logged on at 14 51 23 FRI JUNE 20 2003 Multiple Event List 34 admin logged on at 14 40 28 FRI JUNE 20 2003 Version Information 33 admin logged on at 14 40 25 FRI JUNE 20 2003 NUP Port Statistics Summary 32 admin ogged on at 14 40 22 FRI JUNE 20 2003 E NOD1 AM2020 31 admin logged on at 14 40 15 FRI JUNE 20 2003 30 admin logged on at 14 40 09 FRI JUNE 20 2003 29 admin logged on at 14 39 58 FRI JUNE 20 2003 SI HOE Nro Cd 28 admin logged on at 14 30 51 FRI JUNE 20 2003 I 14N038 NES ESO 27 admin logged on at 14 18 56 FRI JUNE 20 2003 N082 NFS 3030 26
27. Any warning device may fail to alert people with a disability or those who have recently consumed drugs alcohol or medica tion Please note that Strobes can under certain circumstances cause seizures in people with conditions such as epilepsy Studies have shown that certain people even when they hear a fire alarm signal do not respond or comprehend the meaning of the signal It is the property owner s responsibil ity to conduct fire drills and other training exercise to make people aware of fire alarm signals and instruct them on the proper reaction to alarm signals n rare instances the sounding of a warning device can cause temporary or permanent hearing loss A fire alarm system will not operate without any electrical power If AC power fails the system will operate from standby batteries only for a specified time and only if the batteries have been properly maintained and replaced regularly Equipment used in the system may not be technically com patible with the control It is essential to use only equipment listed for service with your control panel Telephone lines needed to transmit alarm signals from a premise to a central monitoring station may be out of service or temporarily disabled For added protection against tele phone line failure backup radio transmission systems are rec ommended The most common cause of fire alarm malfunction is inade quate maintenance To keep the entire fire alarm system in
28. B SERVER TO MODEM You can connect the NFN Web Server to a modem allowing communication between the server and the browser via telephone lines The modem must be supplied by the customer the cable comes with the NFN Web Server PC board NOTE The modem used must be ITE listed equipment N NEN Web Server red line on this end PC board Modem connector J4 Modem cable supplied with Web Server assembly NOTE Make sure the red line on the ribbon lines up with the top of the modem connector Figure 2 7 1 10 Pin to DB 9 Connection Modem Connection 18 NEN Web Server User s Manual PN 51990 A2 12 02 03 www PDF Zoo com 2 8 ETHERNET NETWORK CONNECTION This connects the NFN Web Server to the Internet or Intranet A PNET 1 surge suppressor must be used between the Web Server PC board and the network Using the RJ45 cable plug one end into the PC board and the other into the square end of the PNET 1 Then connect another RJ45 cable from the PNET 1 out to the network The NEN Web Server can be used as a web based gateway for communication between NOTI FIRE e NET and Veri FireTM Tools The Ethernet port on the Web Server computer connects to the Ethernet port on the VerieFireTM Tools computer For details on using VerieFire Tools with the NEN Web Server consult the VerieFireTM Tools online help NFN Web Server AE to PNET 1 j To Internet or Intranet n Ed y EN I PNET 1 surge suppressor
29. Connector NOTE Not needed for direct A connection to an NFS 640 or NFS 3030 panel Figure 2 5 2 NFN Web Server Power Connection NEN Web Server User s Manual PN 51990 A2 12 02 03 NWS Power SUPPLY CONNECTIONS WHEN CONNECTING DIRECTLY To THE NFS 640 or NFS 3030 When connecting the NWS directly to an NFS 640 or NFS 3030 make cable connections according to Figure 2 5 3 below 24V REF Input 24VDC Input Earth 5VDC Output P N 46175 5V REF Output P E pop To NWS PC Board Power Connector Figure 2 5 3 NWS Power Supply Connections for Direct Panel Interfacing NFN Web Server User s Manual PN 51990 A2 12 02 03 www PDF Zoo com 17 2 6 DB 9 To NUP CONNECTION NFN WEB SERVER TO NCM W F or NUP DIRECT CONNECT Connecting the NFN Web Server to an NCM W F allows the Web Server to communicate with devices on the NOTI FIRE NET network Use the NCM W with twisted pair wire and the NCM F with fiber optic cable The NEN Web Server can also connect directly to an NFS 640 or NFS 3030 panel via the NUP port on the CPU 640 or CPU 3030 Make connections according to Figure 2 6 1 below NUP end connect to outer NUP port J2 4 L connection to an NCM W F or ie X H DB 9 end connect i gt an NFS 640 or NFS 3030 to EIA 232 port on Web Server NFN Web Server DB9 to NUP cable C Board P N 75554 Figure 2 6 1 DB 9 to NUP Connection 2 7 MODEM CONNECTION NFN WE
30. EE ASE ojojo o la ka i ap El o Ex x Ed 4 5 ed ale E La La Alert o Blinking No82 NFS 3030 Internet Figure 4 7 1 Panel Properties Display Sample 44 www PDF Zoo com NEN Web Server User s Manual PN 51990 A2 12 02 03 a Louisville Design Center Microsoft Internet Explorer Ele Edit view Favorites Tools Help amp Bak v gt 2 A Qsearch Favorites History bv Y mJ a a Address E http 179 12 86 119 y 6o Links Louisville Design Center NWS Explorer Object Node 82 Loop 1 MENU E Monitoring Protiles Node Mapping Password Configuration O Authorization Log Wiring Style Style 4 vite Detector Poll Type O Version Information Module Poll Type CLIP E NUP Port Statistics Summary Rapid Poll Enable INO N001 AM2020 Detector Blink es E N007 NFS 640 E NO08 NFS 640 E N038 NFS 640 N077 NFS 640 N078 NFS 3030 E N082 NFS 3030 Eli Loop 1 Modules Panel Modules Zones Logic Zones Release Zones Trouble Zones Custom Action Messages Occupancy Schedule E History Alarm History All History O NUP Port Statistics Summar N087 NWS LOCAL E Loop 1 8h Internet v Figure 4 7 2 Loop Properties Sample Screen E Louisville Design Center Microsoft Internet Explorer 5 x Ele Edit view Favorites Tools Help Bak v gt A A search Favorites History Ey S TH Address E http 179 12 86 119 v
31. F Zoo com LAUNCHING VERIFIRE TooLs This section describes how to access NFN Web Server configuration information using Veri FireTM Tools 1 Under Connection Type select IP Ei Hardware Connection x To determine what options will be available from the VeriFire Tuals please choose the type of hardware you wi be connecting to or the existing database you weuld like to open Connection Type NCS Offline Local installed Database Mode Start a New Database C Use an Existing Database Start a New Database New Hardware Configuration Network Address Stand alone NFS 640 y C Network Node Address o 2 Hardware Database Version 3 0 v 2 VerieFire will then prompt for a session name and password To set up a new session click on New To determine what options will be available from the VeriFire Tools please choose the type of hardware you will be connecting to or the existing database you would like to open NCS C Local Installed Delete Password I Properties Figure 3 4 4 Selecting the Connection Type 3 Enter the IP address for the Web Server in the Primary Event Manager field and click Next gt gt 4 From the drop down list select the Site on which the Web Server will reside and click Next gt gt Site Server NFN Nion NWS 5 If the system contains multiple Web Serv
32. NO38 NFS 640 NO53 NCA N078 NCA NO82 NFS 3030 N087 NWS LOCAL 36 www PDF Zoo com Fire Alarm Trouble Supervisory Security Prealarm Disabled Point Other Figure 4 3 4 1 Yes v Yes v Yes v No 7 Change Settings Monitoring Profiles NEN Web Server User s Manual PN 51990 A2 12 02 03 4 3 5 NopE MAPPING Selecting System Administration Node Mapping allows the user to map nodes that are active on the NOTI FIRE NET network When the Auto Detect command is performed the NFN Web Browser will determine whether a point node is online or offline Then you can use the Node Mapping links to view the results of the auto detection For any node that is online you must select Mapped for the NFN Web Browser to display events from that node then click on the Change Settings button at the bottom of the web page The Auto Detect command located at the bottom of the screen will mark all online nodes as mapped and all offline nodes as unmapped If Unmapped the NFN Web Browser will not display events from that node You will not see events or properties from any new nodes until they are mapped from this page NOTE The default value for node status is Unmapped a Louisville Design Center Microsoft Internet Explorer Ele Edit view Favorites Tools Help Heak y gt gt OA A Asearch Favorites History B 3 El E Sd Address E hitp 179 12 86 119 v so Links
33. P N 51990 A2 ECN 03 340 NOTIFIER NOTI FIRE NET Web Server Installation Operation Manual Document 51990 12 02 03 Rev A2 www PDF Zoo com Fire Alarm System Limitations While a fire alarm system may lower insurance rates it is not a substitute for fire insurance An automatic fire alarm system typically made up of smoke detectors heat detectors manual pull stations audible warn ing devices and a fire alarm control with remote notification capability can provide early warning of a developing fire Such a system however does not assure protection against property damage or loss of life resulting from a fire The Manufacturer recommends that smoke and or heat detec tors be located throughout a protected premise following the recommendations of the current edition of the National Fire Protection Association Standard 72 NFPA 72 manufacturer s recommendations State and local codes and the recommendations contained in the Guide for Proper Use of System Smoke Detectors which is made available at no charge to all installing dealers A study by the Federal Emer gency Management Agency an agency of the United States government indicated that smoke detectors may not go off in as many as 35 of all fires While fire alarm systems are de signed to provide early warning against fire they do not guar antee warning or protection against fire A fire alarm system may not provide timely or adequate warning or simply may not
34. R LS irrita 31 4 3 2 E mail Notification csccscsssssssssssssscssseesessssseesssssssessssssssesssssessseecsseacsseeceevscsessssesessesaseesssessssessssesseers 32 Figure 4 3 2 1 E mail Configuration ettet ainda 32 Figure 4 3 2 2 E mail Profile Configuration esses nennen nennen tnnt nennen rennen nennen 33 Figure 4 3 2 3 Email Configuration Custom Messages sess nennen eene re neennennee 34 Figure 4 3 2 4 Sample Email Message sssrini eene nennen reet nennen nennen ene teen retener ens 34 4 3 3 System A AO 35 Figure 4 3 3 1 System Settings eee Ir t gore eau denen ei Ri due i aei deve ase eiae eo tias 35 4 3 4 Monitoring Profiles e osasse essais siseosas east kdessns a 36 Figure 4 3 4 1 Monitoring Profiles eee ttbi eene Eee ee te pee ette shes ddd ndd 36 4 3 5 Node Mapping e a seen 37 Pigure 4 3 5 1 Node Mapping eite to err ertt eere ete e liada ae 37 4 3 6 Password Configuration ussussassnssnssnsnnsonsnnsnnsnnsnnsnnsonsnssnssnssnsnnsnnsnnsnnsnnsnnsnnsnnsnnsnnsnssnnsnssnsnnsnnsnnsnnsnnsnnsnnsnnee 38 Figure 4 3 6 1 User Configuration viii 2 citet ederet ire the ort pe Eee or PU ans NEE 38 4 3 7 Authorization Log e M 39 Figure 4 3 7 1 Authorization Log een e tei teer anne IE spass lass Ri 39 AA MULTIPLE EVENT LIST anna 40 Figure 44 15 Event List SUMMA eene Ud e ete e
35. User s Manual PN 51990 A2 12 02 03 www PDF Zoo com Once an event type is selected details are displayed on the resulting screen If there are no events for a chosen event type the screen will display a message saying No events exist in this category NOTE The Web Server automatically extracts custom labels from panels when displaying events on an as needed basis When there are many classic panel events i e AM2020 AFP1010 this process may take 30 40 seconds per page The NWS will remember the extracted labels once it has detected them The Previous hyperlink will display the The Next hyperlink will display the next ten previous ten events in the list events in the list Z Louisville Desig Center Microsoft Internet Explorer Ele Edit view F xorites Tools Help Bak gt O A A search Favorites History ESv 9 El a a v 6o Links MENU NWS Home Page J Notifier System Administration E Auto Point Detect For All Pa E E Mail Notification O System Settings E Monitoring Profiles Next 001 ACKNOWLEDGED FIRE ALARM Detector L01D013 RM 101 DET Zone 2001 Z001 SMOKE PHOTO 03 37 53P FRI SEP 05 2003 NO082L010013 E Node Mapping Password Configuration O Authorization Log Multiple Event List Fire Alarm O Trouble O Supervisory g Security L Prealarm O Disabled Point Other Version Information NUP Port Statist
36. al PN 51990 A2 12 02 03 www PDF Zoo com 4 3 3 SYSTEM SETTINGS Selecting System Administration System Settings allows you to make NFN Web Server browser configuration settings sign Center Microsoft Internet Explorer Ele Edit view Favorites Tools Help Back v 2 A search sdFovorites Buistory rv Y El E iJ Address hitp 179 12 86 119 x Links Louisville Design Center NWS Explorer Object System Administration Syst i MENU NWS Home Page O Notifier E System Administration O Auto Point Detect For All Panels Site Link E Mail Notification EJ System Settings Site Link Name E Monitoring Profiles Node Mapping O Password Configuration Site Name Louisville Design Center http www notifier com i Notifier General Settings O Authorization Log Non Admin User Access Enabled y ZZ Multiple Event List E Version Information Network Update No MENS NO01 AM2020 B Nove aFP 200400 Trouble Reminder vos II N005 AFP 200 1007 eo Event Refresh Time 0 or 3 90 seconds e D read Unecinowledged Beep AAA NO38 NFS 640 NOS3 NCA E N078 nea we woo Node Address Fr N087 NWS LOCAL style7 DE Change Settings Figure 4 3 3 1 System Settings SITE SETTINGS Site Name This is a user defined field designed to facilitate a unique descriptive name for the NFN Web Browser Site Link This is a user defined field that allows you to add
37. automatically fill in the password for the chosen User Name on the current PC NOTE Passwords are case sensitive 4 2 THE BROWSER INTERFACE OPERATION 2 x Enter Network Password m Please type your user name and password Site 199 62 76 87 Realm NFN Web Server User Name Save this password in your password list Password Cancel Figure 4 1 1 NFN Web Server Login Dialog The NEN Web Browser Interface displays information about all points present and active on NOTI FIRE NET The browser is the standard Microsoft Internet Explorer format For details on navigating Microsoft Internet Explorer consult its corresponding documentation or help file The display screen is divided into two sections on the left hand side is an Explorer style collapsable expandable tree to choose specific nodes and browser configuration menu items The right area of the screen displays the chosen option such as properties for a device on a specific node or configuration setting fields for a selected configuration option Louisville Design Center Microsoft Internet Explorer Ele Edit View Favorites Tools Help The NWS Home Page Heak v 9 O A A search Favorites History yw 3 Sf El a link navigates to the Address amp http 179 12 86 119 X Links main screen shown in ERE this example Object NWS Home Page 7 NWS Home Page Notifier E System Administration 5 Multiple Event L
38. class A computing device pursuant to Subpart B of Part 15 of FCC Rules which is designed to provide reasonable protection against such interference when operated in a commercial environment Operation of this equipment in a residential area is likely to cause interference in which case the user will be required to correct the interference at his own expense Canadian Requirements Like all solid state electronic devices this system may operate erratically or can be damaged when subjected to light ning induced transients Although no system is completely immune from lightning transients and interferences proper grounding will reduce susceptibility Overhead or outside aerial wiring is not recommended due to an increased sus ceptibility to nearby lightning strikes Consult with the Techni cal Services Department if any problems are anticipated or encountered Disconnect AC power and batteries prior to removing or in serting circuit boards Failure to do so can damage circuits Remove all electronic assemblies prior to any drilling filing reaming or punching of the enclosure When possible make all cable entries from the sides or rear Before making modifi cations verify that they will not interfere with battery trans former and printed circuit board location Do not tighten screw terminals more than 9 in Ibs Over tightening may damage threads resulting in reduced terminal contact pressure and difficulty with screw termina
39. device status and property settings In addition to fire alarm control panels the NFN Web Browser also allows you to view network devices such as the Network Control Station NCS Network Control Annunciator NCA and the UniNet Gateway NOTE Reference the pertinent control panel user manual for property details MES 3 Louisville Design Center Microsoft Internet Explorer Ele Edit view Favorites Tools Help Bak y gt v A Search Favorites History Y S Ed 8 SJ Address http 179 12 86 119 v Po Links Louisville Design Center NWS Explorer MENU N082 NFS 3030 E Loop 1 E Modules L01M013 I E L01M017 I EJ L01M077 O Panel Modules Zones Logic Zones Network Address Media Channel A Threshold Media Channel B Threshold Media Style 7 E Release Zones PERIPHERALS Trouble Zones Remote LCD Supervision E Custom Action Messages PrinterFormat Printer Supervision E Occupancy Schedule O Schedule 1 O Schedule 2 gO Schedule 3 Time Format E Schedule 4 Date Format EJ Senedule s Alarm Scrolling n Sacer LCD Backlight Mode O Schedule 7 E le LCD Intensity O Schedule 9 O Schedule 10 El Holidays Trouble Reminder E History Bell Coding Mode Alarm History Prealarm Mode O All History LED Blink ul Local Control Main Power Supply Address HAR HH MM AM PM zZ A ES zlolz pd jen nu a an
40. e O Notifier System Administration Multiple Event List O Version Information NUP Port Statistics Summary Noo1 AM2020 N007 NFS 640 N008 NFS 640 N038 NFS 640 N082 NFS 3030 N087 NWS LOCAL N087 NWS LOCAL N087 NWS LOCAL N087 NWS LOCAL Count 2 yte Time n mer ze er SSS e Da EM Eee men C I cC NN NK VE NUP Port Statistics Summary Figure 4 6 1 NUP Port Statisctics Overview NOTE Only Onyx Series products NFS 3030 NFS 640 NCA will have version information displayed A Louisville Design Center Microsoft Internet Explorer 8 x Ele Edit View Favorites Tools Help HBk v gt v O A Qsearch Garavorites G Ay S El v El Links gt Louisville Design Center NWS Explorer MENU Ol NWS Home Page O Notifier System Administration Multiple Event List O Version Information O NUP Port Statistics Summary 001 AM2020 1002 AFP 300 400 N038 NFS 640 N053 NCA N078 NCA N082 NFS 3030 E N087 NWS LOCAL NUP Port Statistics Object Node 87 NUP Port Statistics Reset Statistics dE NUP Port Statistics 8 internet Figure 4 6 2 Local Node NUP Port Statisctics NEN Web Server User s Manual PN 51990 A2 12 02 03 43 4 7 SCREEN DETAILS AND OPTIONS FOR SPECIFIC PANELS For any panel or device that is on the network there will be a corresponding hyperlink option in the NFN Web Server menu list These screens are for viewing panel network
41. e Underwriters Laboratories Standard UL 864 e NFPA 72 National Fire Alarm Code e CAN ULC S527 M99 Standard for Control Units for Fire Alarm Systems e UL 1076 Proprietary Burglar Alarm Units and Systems The contents of this manual are important and must be kept in close proximity of the hardware If building ownership is changed this manual and all other testing and maintenance information must also be passed to the current owner of the facility A copy of this manual was shipped with the equipment and is also available from the manufacturer WARNING Improper installation maintenance or lack of routine testing could result in system malfunction 1 5 COMPATIBILITY The NEN Web Server is compatible with NOTI FIRE NET version 5 0 and later of the following panels and devices e NFS 640 version 2 0 NCM W F e NFS 3030 version 2 0 NCM W F NOTES The NFN Web Server is not e AM2020 version 5 0 SIB intended as a primary annunciator and e AFP 1010 version 5 0 SIB is ancillary in nature e AFP 200 version 5 0 NAM events only No NCM is required when the NFN Web e AFP 300 400 version 5 0 NAM Server connects directly to an NFS 640 FS 3030 e BACnet Gateway version 2 0 events only BRAUNER NEN NION events only e Network Control Station NCS version 3 0 events only e Network Control Annunciator NCA version 2 0 NCM W F events only 1 6 SYSTEM REQUIREMENTS BROWSER e Microsoft Internet Explorer version 5
42. e located Type the address by double clicking on the data field to the right of the description field The user will type this address into a browser in order to establish a connection with the Web Server If the Web Server is to be used on the internet you may need to independently set up a router and or firewall so the internet based applications can locate and access the Web Server Contact your MIS department for details To actually connect to the Web Server requires use of TCP IP port 8888 for example if the NWS is located at 10 4 2 1 one would type the following into the browser window to connect to the Web Server http 10 4 2 1 8888 NOTE Fields marked with an asterisk are editable within their respective data fields VeriFire Tools Read Status Service 2 olx E Panel Main Services Spreadsheets Reports View Utilities Network Diagnostics Documents Help x HEE COO nudo 4 4B m NmcaN 5 AECE 48 Current Network 87 Close Node Address NFN Web Server Node 87 IP address for connection to Notifier 101 101 101 101 Subnet mask 255 255 255 0 IP address for routing back to Internet 101 101 101 1 Upload Download IP address assigned to PPP modem Network number 87 Port A High Port B High This is the node Style 4 i number N Description Field Data Field Documentation E8 Read Status Service gAstart 4 E O NTSR
43. ers select the Web Server node number from the drop down list and click Next gt gt Primary Event Manager mi 111111 111 Local01 v Description Test SEE a 6 Enter a unique description for the session you are establishing and click Next gt gt Figure 3 4 5 26 www PDF Zoo com Configuring the Web Server Connection Session NEN Web Server User s Manual PN 51990 A2 12 02 03 jad Hardware Connection B To determine what options will be available y from the VeriFire Tools please choose the type of hardware you will be connecting to or the existing database you would like to open a o AA 7 Once the session has been created o1 enter the Veri Fire M system password A a nen PH PRI and click OK Figure 3 4 6 Veri Fire Tools System Password Once you are online VeriFire Tools will prompt you to select the Hardware Connection which will be NFN Web Server as seen in Figure 3 4 7 Double click on it to proceed to the configuration screen Hardware Connection To determine what options will be available from the VeriFire Tools please choose the type of hardware you will be connecting to or the existing database you would like to open on line NFS 3030 Remote Connect Figure 3 4 7 Selecting the Connection Type NEN Web Server User s Manual PN 51990 A2 12 02 03 27 www PDF Zoo com CHANGING THE NODE NUMBER The Node Number or Drop Number
44. function for a variety of reasons Smoke detectors may not sense fire where smoke cannot reach the detectors such as in chimneys in or behind walls on roofs or on the other side of closed doors Smoke detec tors also may not sense a fire on another level or floor of a building A second floor detector for example may not sense a first floor or basement fire Particles of combustion or smoke from a developing fire may not reach the sensing chambers of smoke detectors be cause Barriers such as closed or partially closed doors walls or chimneys may inhibit particle or smoke flow Smoke particles may become cold stratify and not reach the ceiling or upper walls where detectors are located Smoke particles may be blown away from detectors by air outlets e Smoke particles may be drawn into air returns before reach ing the detector The amount of smoke present may be insufficient to alarm smoke detectors Smoke detectors are designed to alarm at various levels of smoke density If such density levels are not created by a developing fire at the location of detectors the detectors will not go into alarm Smoke detectors even when working properly have sensing limitations Detectors that have photoelectronic sensing chambers tend to detect smoldering fires better than flaming fires which have little visible smoke Detectors that have ion izing type sensing chambers tend to detect fast flaming fires better than
45. he server at a time A The server can support an intranet internet connection simultaneously with a dialup connection 10 NEN Web Server User s Manual PN 51990 A2 12 02 03 www PDF Zoo com NEN WEB SERVER INTERFACE TO STANDALONE PANEL NFS 640 or NFS 3030 The NFN Web Server can directly interface with an NFS 640 or NFS 3030 panel to connect them via Internet Intranet to a PC browser A DB 9 to NUP cable is used to make the connection PC Browser Interface The NWS connects directly to an NFS 640 or NFS 3030 via a 1 re Internet Intranet or DB9 NUP cable Dial Up NFS 640 u or s NFS 3030 ml NWS NOTE No NCM is required when the NWS connects directly to an NFS 640 or NFS 3030 Figure 1 7 3 NFN Web Server Direct Panel Interface Architecture NEN Web Server User s Manual PN 51990 A2 12 02 03 11 www PDF Zoo com NOTES 12 NEN Web Server User s Manual PN 51990 A2 12 02 03 www PDF Zoo com SECTION TWO NFN WEB SERVER HARDWARE INSTALLATION 2 1 REQUIRED COMPONENTS does not increase the burglary grade of service The NEN Web Server requires the following equipment NOTE The NWS is for ancillary use only and NEN Web Server Assembly PC board P N 46173 for the NFN Web Server for the system e Power supply P N 46175 24VDC to 5VDC e PNET 1 surge suppressor e CATS cable P N 75585 provides Ethernet connection cable between NEN Web Server PC board and PNET
46. ics Summary ND01 AM2020 N007 NFS 640 N008 NFS 640 N038 NFS 640 N082 NFS 3030 N087 NWS LOCAL sz EE E E E E Fire Alarm 8 Internet Figure 4 4 2 Multiple Event List Details The zone The device type The event number The event name if applicable 7 l 003 FIRE ALARM Second Floor Zone 02 z002 SMOKE ION 11 27 40A FRI 002 FIRE ALARM DETE a Custom label Extended custom label revious West Wing SEP 06 2002 N045L01D010 Zone 7 2077 SMOKE PHOTO 10 20 21A FRI SEB NO040L 1D002 001 FIRE ALARM DETECTOR HALLUWAA Zone 03 2003 SMOKE PHOTO 10 20 03A SEP 06 2002 NO40LO 1DO90 Event details including the date The address where the event occurred time the event occurred In this example the Fire Alarm entry provides the exact device address NEN Web Server User s Manual PN 51990 A2 12 02 03 41 www PDF Zoo com 4 5 VERSION INFORMATION This link navigates to a screen that contains a list of panels annunciators and related monitoring devices and the corresponding version information for them and their related network interfaces z Louisville Design Center Microsoft Internet Explorer MEE File Edit view Favorites Tools Help Bak y gt A Search Favorites CBuistory Y amp aaa Address E nttp 179 12 86 119 y Links Louisville Design Center NWS Explorer Object Aversion Informa
47. ign Center Microsoft Internet Explorer xj Ele Edit View Favorites Tools Help Heak v gt v O 2 A Qsearch Gjrevorites Ey S El v El Links gt Louisville Design Center NWS Explorer Object System Administration E Mail Profiles Profile 3 MENU PROPER TY VALUE z a o FE FE NNNM NNUM ma 9003 NFS 640 s COMINO PCI EOS ECO ECO FE ETS El E Mail Notification Nose NFS 640 gt PE C Ee Bien 7 poenrsono ei E CIS CIN E E CI CH ETE None Es js js m jm w m das None Es js a ee EI Profle 6 None Es js u ee El Profile 7 None w a PP ee Custom messages are defined EE None mm according to event type and have EE Custom Messages a 50 character maximum cs Node Mapping Fire Alarm Report to node site immediately El E de dM Trouble Please Call security office E EJ Multiple Event List Supervisory Can security office as soon as possible O Version Information E NUP Port Statistics Summary Security Report to node site immediately A EJ N001 AM2020 E NO02 AFP 300 400 Pre Alarm Can security office as soon as possible EE Disabled Point N008 NFS 640 ei adi mme f otter E Profe 3 eg internet Figure 4 3 2 3 Email Configuration Custom Messages In the example illustrated in Figure 4 3 2 3 above custom messages have been defined for various event types Above the Custom Messages area NCA nodes
48. ill be available d from the VeriFire Tools please choose the Ar Fi type of hardware you will be connecting to or 1 7 the existing database you would like to open Connection Type C Offline Local C IP Figure 3 4 1 Veri Fire Local Connection Type 4 Next double click on the NFN Web Server entry on the Nodes screen This will bring up the main configura tion screen that will be used to set up the NFN Web Server for communication over the network x Node Node Type State NFN WEB SERVER Direct Connect Figure 3 4 2 Nodes Screen 5 Before making Web Server configuration settings assign the Web Server a NrsRuntime gt veririre Tools unique NEN node address From the Veri FireTM menu bar select Panel Node a ES E Bnew ession Address Change Js EI Save Node Data Y Save Node Data As Close Service E Nodes on Network Login El Node Password Change EM Node Address Change AU Exit VeriFire Tools 6 Type in the node address and click Update to apply the changes xl Currently Logged In Node 87 The Web Server can now be configured for communication over New Node Address NOTI FIRE NET Update Cancel 24 NEN Web Server User s Manual PN 51990 A2 12 02 03 www PDF Zoo com The following fields must be configured to run the NFN Web Server IP address for connection to Notifier This is the actual IP address where the Web Server will b
49. ist The link below the NWS Home Page link navigates to the custom defined URL configured in System Settings Version Information NUP Port Statistics Summary NO01 AM2020 NOD2 AFP 300 400 NOOS AFP 200 NOD7 NFS 640 NOOS NFS 640 E NO38 NFS 640 NOS3 NCA E NO78 NCA NO82 NFS 3030 N087 NWS LOCAL Version 002 000 008 NCM Version 002 000 015 15 04 26 Aug 15 2003 Figure 4 2 1 NWS Home Page NEN Web Server User s Manual PN 51990 A2 12 02 03 www PDF Zoo com 29 4 3 SYSTEM ADMINISTRATION The System Administration setup options configure various NFN Web Server settings and can only be accessed by administrator level operators 4 3 1 Auto DETECT POINTS ON ALL PANELS This option will auto detect AFP1010 AM2020 points on NOTI FIRE NET How Points Become Visible To The Web Server There are three ways a point becomes visible to the Web Server 1 With Onyx series panels points are detected automatically when the Web Server is connected to the network on which those panels reside Therefore point detection for ONYX series panels requires no user action 2 With AFP1010 AM2020 panels points are only detected when a user clicks on the AutoDetect menu item either under the individual AFP1010 AM2020 panel s menu or under System Administration Although the feature is called Auto Detect this requires the user action of clicking on the Auto Detec
50. l removal Though designed to last many years system components can fail at any time This system contains static sensitive components Always ground yourself with a proper wrist strap before handling any circuits so that static charges are re moved from the body Use static suppressive packaging to protect electronic assemblies removed from the unit Follow the instructions in the installation operating and programming manuals These instructions must be followed to avoid damage to the control panel and associated equipment FACP operation and reliability depend upon proper installation by authorized personnel This digital apparatus does not exceed the Class A limits for radiation noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications Le present appareil numerique n emet pas de bruits radio electriques depassant les limites applicables aux appareils numeriques de la classe A prescrites dans le Reglement sur le brouillage radioelectrique edicte par le ministere des Communications du Canada Acclimate Plus HARSH NOTI FIRE NET ONYX and VeriFire are trademarks and FlashScan and VIEWO are registered trademarks of NOTIFIER NION and UniNet6 are trademarks of NIS NIS and Notifier Integrated Systems are trademarks and NOTIFIERG is a registered trademark of FireeLite Alarms Inc Echelon6 is a registered trademark and LonWorks is a
51. l addresses of the recipients assigned that profile along with the nodes and event types that will initiate an e mail message Profiles filter e mail notification by event type The six event types are Fire Alarms Pre Alarms Securities Supervisories Troubles and Other To access E mail Profiles from the menu hierarchy on the left click on System Administration then click on E mail Profiles to expand the selection to display the ten profiles 1 2 3 4 5 or Select the profile to define from the list on the left Enter the e mail addresses to be included in the profile for notification Choose the node panel type to be included for email notification Choose the event types to be included for email notification Note that these are set on a per node basis Configure custom messages see Figure 4 3 2 3 After making all settings for the profile click on Save Profile to apply the settings Disable Profile By checking the Disable Profile option this will prevent e mails from being sent for this profile until the box is un checked Profiles are enabled by default Each profile can define up to ten nodes that will be included in e mail notification This includes an all nodes setting as well Each profile can define up to five e mail addresses to which the profile will apply E Louisville Design Center Microsoft Interne Explorer Ble Edit view Favorites Tools Help Back v gt A A
52. n Intranet With the NFN Web Server interface the user can view the history of a fire alarm control panel FACP event status device properties and other information based on access permissions defined by the system administrator All data available on the web server is a snapshot of the data on the NOTI FIRE NET network at the time the browser requested the information The NFN Web Server communicates to NOTI FIRE NET version 5 0 and later The NFN Web Server interfaces to the Internet Intranet using an IP based wire Ethernet connection or through a direct dial up connection using a modem The Serial Configu ration Tool allows you to make the necessary network configuration settings for the web server to be able to communi cate with the browser 1 2 NEN WEB SERVER SERIAL CONFIGURATION TOOL FEATURES Below are some of the features of the NFN Web Server and Serial Configuration Tool e Ability to access NOTI FIRE NET device and system statuses and properties remotely via the Internet Intranet or direct dial up connection Compatible with NOTI FIRE NET version 5 0 and later e Serial Configuration Tool runs on any laptop or PC using Windows and having an open COM port e One web server supports multiple users e Standard IP over Ethernet connection e Up to 128 user accounts are supported e Built in password security and user access record e Supports standard Microsoft Internet Explorer 5 e Intuitive Explo
53. n in the top right corner IMPORTANT When the NFN Web Server is first being configured you must use this direct serial connection to initially establish communication between the Web Server and the PC PC COMMUNICATING TO NFN WEB SERVER VIA NCM NOTE Tuis OPTION IS ONLY USED WHEN IT IS NECESSARY TO RE CONFIGURE THE WEB SERVER SETTINGS For a PC Communicating to NFN Web Server Via the NCM run the Serial Port Configuration Utility to establish communications NUP Serial Port Auto Configuration m EJ x SUCCESS NUP auto configured to COM2 Auto Configuration Figure 3 3 1 Serial Port Configuration Utility NOTES If the Web Server is to be connected via an NCM you must specify the node A number being used for the NFN Web Server by accessing VerieFire Tools If the NFN Web Server does not yet have a node number the PC must be connected directly to the Web Server first to give it one NOTE To configure the NWS via an NCM you must have a NUP to DB9 cable P N 75554 sold separately NEN Web Server User s Manual PN 51990 A2 12 02 03 23 www PDF Zoo com 3 4 INITIAL SETUP OF THE NFN WEB SERVER 1 Make a PC to PC hardware connection between Veri FireTM and the NFN Web Server see Figure 2 9 1 2 Open Veri Fire M by selecting Start Programs VeriFire Tools VeriFire Tools 3 Select Local from the Connection Type area of the screen then click OK z Hardware Connection x Y To determine what options w
54. nnonancnnnroncnno nono nnncnn cnn nonnnnn eere 14 2 3 INSTALLING THE NFN WEB SERVER ASSEMBLY INTO A CAB 4 SERIES CABINET eere 15 Figure 2 3 1 NEN Web Server Installation Diagram oooconnnicnnocnnonconnnononnnonncnnnonncnnocononn cnn ono n cnn nn cra non etre 15 2 4 NEN WEB SERVER PC BOARD LAYOUT scsscsccscisusssunctpssdscenetoacsoussesessesaceseveevassesensesesennssteeorsteusectocveassaseos 15 Figure 2 4 1 PC Board Layout eee een era mais a ui 15 2 5 POWER SUPPLY CONNECTIONS Sn ee ANRH UT NA A FE FON 16 Figure 2 5 1 46175 Power Supply Specifications 20 0 ececeeseesesseesessesseescesceeceececsecsecneesessesaeesessesseeaeeaseeseees 16 Figure 2 5 2 NEN Web Server Power Connection oooococcconconnnonconnonnconnnnnonnncnnonnnonnornnonnonnncnn nro n nan non enn n cane nn non nonos 16 Figure 2 5 3 NWS Power Supply Connections for Direct Panel Interfacing eene 17 2 6 DB 9 To NUP CONNECTION NFN WEB SERVER TO NCM W F on NUP DIRECT CONNECT 18 Figure 2 6 1 DB 9 to NUP Connection terrier ete det tH RE Run nr A 18 2 7 MODEM CONNECTION NFN WEB SERVER TO MODEM eee eee ee eee etna nonet DDN tassa esee teen asses e teta aa 18 Figure 2 7 1 10 Pin to DB 9 Connection Modem Connection cccocccooccnonanoncconnnconncnonncnnncnonncnnncrnncconcnnnnnconcnnnns 18 2 8 ETHERNET NETWORK CONNECTION 5 i5 pekesd s ORE sue LS peau NYD OYD NUS ERE PNEU PEERS SOUPE nano sica oe eet up CURE Uo 19 Fig
55. onnection 19 NFN Web Server Assembly 15 Installation Checklist 14 IP ASSIGNED TO PPP MODEM CLIENTS 22 IP Configuration 22 IP FOR ROUTING BACK TO INTERNET 22 L Login 29 M Monitoring Profiles 36 Multiple Event List 40 41 N NCM Configuration 22 NCM Settings 35 Network Configuration 21 Network Connection 19 NEN Web Server User s Manual PN 51990 A2 12 02 03 www PDF Zoo com NUP Port Statistics 43 NEN Web Server Network Configuration 21 NEN Web Server PC Board Layout 15 Node Address Change 28 Node Mapping 37 P Password Configuration 38 Passwords 29 PC Board Layout 15 Power Supply 16 R Regulatory Standards 8 Related Documentation 7 S Security 29 Serial Port Configuration Utility 23 Site Settings 35 SUBNET MASK 22 System Administration 30 Monitoring Profiles 36 Node Mapping 37 Password Configuration 38 System Architecture 9 System Settings 35 General Settings 35 NCM Settings 35 Site Settings 35 V VeriFire Tools 23 Connection Type 27 IP address assigned to PPP modem 25 IP address for connection to Notifier 25 IP address for routing back to Ineternet 25 Launching 26 NCM Threshold and Network Styles 25 Node Address Change 28 W Web Server Node 21 Wiring Network Interface 18 Power Supply 16 Serial Configuration Tool 21 47 NOTES 48 NEN Web Server User s Manual PN 51990 A2 12 02 03 www PDF Zoo com NEN Web Server User s Manual PN 51990 A2 12 02 03 www PDF Zoo com NOTES
56. rer user interface e Sends up to 50 emails in response to any system event 1 3 RELATED DOCUMENTATION Below is a list of NOTI FIRE NET related documentation For information on Refer to Compatible Devices Device Compatibility Document Cabinets amp Chassis CAB 3 CAB 4 Series Installation Document Auxiliary Power Supplies amp Battery Chargers ACPS 2406 Installation Manual Veri FireTM Tools on line help file VeriFire TCD Veri FireTM Medium Systems on line help file VeriFire CD Veri FireTM Tools CD Insert 51871 Offline Programming Utility Noti Fire Net Manual NCM W F Installation Document MIB Media Interface Board VeriFire TCDNetworking NCS Network Control Station NCA Network Control Annunciator BACnet Gateway NFS 640 Installation Operation Programming manuals 51332 51334 51333 NFS 3030 Installation Operation Programming manuals 51330 51344 51345 Network Control Annunciator NCA 51482 Network Control Station NCS 51095 AFP 200 Instruction manual 15511 AFP 300 400 Installation Operation Programming manuals 50253 50260 50259 AM2020 AFP 1010 Installation Operation Programming manuals 15088 UniNet Online Instruction Manual 51994 Panels and Annunciators Table 1 3 1 Related Documentation NEN Web Server User s Manual PN 51990 A2 12 02 03 7 www PDF Zoo com 1 4 STANDARDS AND SPECIFICATIONS The NFN Web Server has been designed to comply with standards set forth by the following regulatory agencies
57. scovery This lets you know that the Auto Detect task is currently being performed This line denotes the current progress of the Auto Detect task wser will refresh with the node list when e Internet This option allows you to cancel out of Auto Detect if necessary Figure 4 3 1 3 Auto Detect Screen Once the Auto Detect has been performed go to the Node Mapping links and make sure that all node numbers that read online are also mapped Refer to section 4 3 4 Node Mapping for more information NEN Web Server User s Manual PN 51990 A2 12 02 03 www PDF Zoo com 31 4 3 2 E MAIL NOTIFICATION SUMMARY The e mail notification feature enables the administrator to configure the NWS to automatically send event information via e mail to a select group of users E mail recipients receive events according to the profiles they have been as signed The NWS can support a maximum of ten profiles and an e mail recipient can be assigned to all ten profiles Each of the ten profiles support a maximum of five e mail addresses E Ma1L CONFIGURATION You will need the following information from your Internet Service Provider ISP or Local Area Network LAN administrator The NWS does not provide authentication information Outgoing Mail IP Address SMTP This is the mail server s IP address The NWS does not support DNS therefore you will need the address in dotted decimal form XXX XXX XXX XXX Mail User This
58. sections NOTE The replacement of the lithium battery of the GENE 4310 CPU Board is to be performed by a trained technician f EIA 232 Port DB9 NUP connector used for operation as the network connection to HDD Power Connector P1 NOTI FIRE NET PC PC connector used for RJ45 Ethernet Connector configuration cable sup CN2 to PNET 1 plied by customer Figure 2 4 1 PC Board Layout NEN Web Server User s Manual PN 51990 A2 12 02 03 15 www PDF Zoo com 2 5 POWER SUPPLY CONNECTIONS The power supply for the NFN Web Server is a 24VDC to 5VDC unit P N 46175 The NFN Web Server requires 24VDC 250 mA nominal and battery backup in accordance with local code requirements It can be powered by any power limited source that is UL listed for use with fire protective signaling units For more details on powering and connecting an NCM W F refer to its Product Installation Document 51533 TYPICAL 24V 5V Output Current 5V ae Figure 2 5 1 46175 Power Supply Specifications ow w_ 360mA without NCM NWS Power SUPPLY CONNECTIONS WHEN USING THE NCM W F When connecting the NWS to NOTI FIRE NET via the NCM W F make cable connections according to Figure 2 5 2 below 16 www PDF Zoo com amp 24v REF Input amp 24VDC Input CBSE Ze 5VDC O COOSL PIN 46175 utput CQO oo Ot CD sv REF Output P N 75583 To NCM NUP Port P N Ne To NWS PC Board Power
59. setup exe from the root directory of the CD ROM 3 This will execute the install application Simply follow the directions on screen to install the Serial Configu ration Tool 4 Once it is installed it can be launched from the Start menu by selecting Programs VerFire Tools NWS Configuration Tool 3 2 UsING THE NWS CONFIGURATION TOOL FOR CONFIGURATION The NWS Configuration Tool configures network parameters of the Web Server When you run the Configuration Tool the following dialog box will be displayed Serial Setup NWS Config Tool x PC Comm part for connection COM NWS Node for connection through NCM fo Figure 3 2 1 NFN Web Server Serial Setup Dialog The Configuration Tool communicates with the Web Server either directly by connecting the PC to the server s serial port or by connecting the PC to the second NUP port of an NCM that is on the same network as the Web Server Note that if connected via an NCM there must also be some type of node connected to the NCM which has caused the NCM to join the network Enter the communications port that the PC is using for its connection to the Web Server When connecting through an NCM the Web Server node must be specified in the window above so the configuration tool can find it When connecting directly the node may be left as zero PC DIRECTLY CONNECTED TO NEN WEB SERVER 1 Select the COM port being used 2 Click OK to finish configuration PC COMMUNICATING TO NFN
60. smoldering fires Because fires develop in differ ent ways and are often unpredictable in their growth neither type of detector is necessarily best and a given type of detec tor may not provide adequate warning of a fire Smoke detectors cannot be expected to provide adequate warning of fires caused by arson children playing with matches especially in bedrooms smoking in bed and violent explosions caused by escaping gas improper storage of flammable materials etc 2 www PDF Zoo com Heat detectors do not sense particles of combustion and alarm only when heat on their sensors increases at a prede termined rate or reaches a predetermined level Rate of rise heat detectors may be subject to reduced sensitivity over time For this reason the rate of rise feature of each detector should be tested at least once per year by a qualified fire pro tection specialist Heat detectors are designed to protect property not life IMPORTANT Smoke detectors must be installed in the same room as the control panel and in rooms used by the sys tem for the connection of alarm transmission wiring communi cations signaling and or power f detectors are not so lo cated a developing fire may damage the alarm system crip pling its ability to report a fire Audible warning devices such as bells may not alert people if these devices are located on the other side of closed or partly open doors or are located on another floor of a building
61. t command 3 With AFP 300 400 panels points are only detected when they generate an event which can then be seen by the Web Server therefore the only way to add points connected to an AFP 300 400 panel is to manually generate an event for each point Events from points that have not been Auto Detected will be shown in the Multiple Events list In other words events coming from a classic panel will be logged even if the points themselves did not previously appear in the hierarchy list at the left of the NWS screen A Note On AFP 200 Panel Points AFP 200 points do not get Auto Detected and they will not be displayed in the hierarchy list on the left However events from an AFP 200 panel and or point will come into the Multiple Event List and can generate an email Selecting this option will navigate to the corresponding ERZIE Design Centers DER Internet Emme BEE n Ele Edit vi Favorites Tc He screen at the right the Auto Point Detect Verification JY Hee Ms dr Heck v gt 7 O 2 A Qsearch s Favorites Ay Ob El v El screen This screen requests that the administrator Address htp 101101101101 8888 Links gt verify the auto discover command as the process can Object System Administration Auto Point Detect For All Panels be time consuming depending on the size of the entire gm ROF ALLE system EJ NWS Home Page Auto Point Detect Verification O Notifier E System Administration x z 010 M Auto
62. testing is required after any change ad dition or deletion of system components or after any modifica tion repair or adjustment to system hardware or wiring All components circuits system operations or software func tions known to be affected by a change must be 100 tested In addition to ensure that other operations are not inadvert ently affected at least 10 of initiating devices that are not directly affected by the change up to a maximum of 50 de vices must also be tested and proper system operation veri fied This system meets NFPA requirements for operation at 0 49 C 32 120 F and at a relative humidity of 85 RH 93 per ULC non condensing at 30 C 86 F However the useful life of the system s standby batteries and the electronic components may be adversely affected by extreme tempera ture ranges and humidity Therefore it is recommended that this system and all peripherals be installed in an environment with a nominal room temperature of 15 27 C 60 80 F Verify that wire sizes are adequate for all initiating and indicating device loops Most devices cannot tolerate more than a 10 I R drop from the specified device voltage FCC Warning WARNING This equipment generates uses and can radi ate radio frequency energy and if not installed and used in accordance with the instruction manual may cause interfer ence to radio communications It has been tested and found to comply with the limits for
63. tion MENU NWS Home Page PANEL SAPP VERSION BOOT VERSION NCM VERS SS Noorawzuzo unknown pa eee ere Auto Point Detect For All Panels MS System Settings E Monitoring Profiles Node Mapping O Authorization Log Multiple Event List Version Information O NUP Port Statistics Summary NOOL AM2020 NOO NFS 640 NOOS NFS 640 NO38 NFS 640 NOS3 NCA N078 NCA N082 NFS 3030 NOS NWS LOCAL El version Information de Internet Figure 4 5 1 Version Information NOTE Only Onyx Series products NFS 3030 NFS 640 NCA will have version information displayed 42 NEN Web Server User s Manual PN 51990 A2 12 02 03 www PDF Zoo com 4 6 NUP Port STATISCTICS There are two NUP Port Statisctics pages From the link menu at the left select NUP Port Statisctics Summary and the Web Server will display a status overview of all nodes and NCMs on the NFN network see Figure 4 6 1 e Individual node statistics can be displayed by clicking on a node in the link menu then selecting NUP Port Statisctics from its menu see Figure 4 6 2 www PDF Zoo com Ai Louisville Design Center Microsoft Internet Explorer File Edit View Favorites Tools Help Back v gt v OA A search Favorites C Ay 3 m4 y El Address fa http 199 62 76 119 8888 y Links gt Louisville Design Center NWS Explorer Object NUP Port Statistics Summary MENU C NWS Home Pag
64. unTime md Wuntted Pant GER N 9 44 AM Figure 3 4 3 NFN Web Server Configuration Settings Subnet Mask This is the IP subnet mask that the Web Server should use to determine whether a connection came from a local network or should be routed on to another network see previous setting All of the IP settings for the Web Server must be on the same subnet for communications to be established between the Web Server and a browser IP address for routing back to Internet This sets the IP of a router that the Web Server can use to locate the browser with which it is communicating This simply sets a path for the Web Server to use to communicate back with the connecting browser IP address assigned to PPP modem This sets the IP that the Web Server will assign to a computer when that computer attempts to connect to the Web Server over the modem connection The Web Server acts as a PPP server with regard to a client computer on the modem connection and one of its responsibilities is to assign the client s IP for purposes of the given modem session This parameter is optional if it is not intended that a browser be used to establish communications via a modem it can be omitted NCM Threshold and Network Styles The NCM threshold can be set to high or low and the network style can be set to style 4 or style 7 Rrefer to the NCM documentation for more details on these fields NEN Web Server User s Manual PN 51990 A2 12 02 03 25 www PD
65. ure 2 8 1 Ethernet Connection ic oett deb desu aan nina kennen 19 2 9 PC TO PC CONNECTION 3 insiste too anta iones innato Fus age SUM Pepe RS EY IV OQ SEP SERV VR PER SURE O 19 Figure 2 9 1 PC to PC Serial Connection esses nennen nennen nennen etre nennen retener R 19 SECTION THREE NFN WEB SERVER CONFIGURATION cusssrsorssossnsssonsssnssnssonsnnnsnnenne 21 3 1 NEN WEB SERVER SERIAL CONFIGURATION TOOL INSTALLATION eee esee enne ennt en notato atas n statuat tnnn 21 3 2 USING THE NWS CONFIGURATION TOOL FOR CONFIGURATION eee essen en nenne tasas tnos tn sns Dn enata sn 21 Figure 3 2 1 NEN Web Server Serial Setup Dialog sese 21 Figure 3 2 2 NEN Web Server Configuration nennen eto re oreet 22 3 3 USING VERI FIRETM TOOLS FOR CONFIGURATION seenesorsnesnennensenesassnenssnnennensnasnnenssnnennenssnsnnesssnnenesnssnrsnenen 23 Figure 3 3 1 Serial Port Configuration Utility essent nne nete rennen 23 3 4 INITIAL SETUP OF THE NEN WEB SERVER sssccscscsdesesseisssevonssdecasuvestuesteossnosastesensodecnsadubsoseisnsiecdsontvasioosveos 24 Figure 3 4 1 VerieFire Local Connection Type sees eene eere nennen net nter 24 Figureca 42 Nodes Screen o decent edt nee T e e tirada 24 Figure 3 4 3 NEN Web Server Configuration Settings esesssseseseeeeeeeeeenneeee nennen reneennrenes 25 Figure 34 4 Selecting the Connection Type 5 teet
66. us o Response Multiple Event List Custom Label ETECTOR ADDR 1D013 o Version Information O NUP Port Statistics Summary Extended Label N001 AM2020 NO07 NFS 640 N008 NFS 640 Detector Type S E ND38 NFS 640 Flashscan Type E Loop 1 E Detectors c L010012 Control By Event 3 ZO ZO ZO ZO J L01D013 EJ L01D014 ALARM PARAMETERS LUDDDDLS Percent of Alarm E uud Percent of Pre Alarm L01020 Alarm Sensitivity O L01D021 Prealarm Sensitivity E L01D023 Compensation Percentage E L01D024 Detector Peak L01D025 L01D026 E L01D027 Co operative Detector Mode one 1010023 Alarm Verification Participation ala y Verification Counter E E Es as N 219 v E BJ Ez Liz E a ojo g 2 ALA 3 3 ojm ia zis E m O gt 319 E o 2 iai S o 4 gt Pre Alarm Mode E Lo1D013 dep Internet v Figure 4 7 4 Detector Properties Sample Screen NFN Web Server User s Manual PN 51990 A2 12 02 03 www PDF Zoo com Index A Auto Discover Points on all Panels 30 31 B Browser Interface 29 C COM Port Configuration 21 Configuration Tool 21 23 COM Port Configuration 21 IP ASSIGNED TO PPP MODEM CLIENTS 22 IP Configuration 22 IP FOR ROUTING BACK TO INTERNET 22 NCM Configuration 22 SUBNET MASK 22 Web Server Node 21 D Device Compatibility 8 Drop Number See Node Address Change E E mail Notification 32 E mail Profiles 33 G General Settings 35 I Installation Hardware Network C
67. will assign to a computer when that computer attempts to connect to the Web Server over the modem connection The Web Server acts as a PPP server with regard to a client computer on the modem connection and one of its responsibilities is to assign the client s IP for purposes of the given modem session This parameter is optional if it is not intended that a browser be used to establish communications via a modem it can be omitted IP FOR ROUTING BACK TO INTERNET sets the IP of a router that the Web Server can use to locate the browser with which it is communicating This simply sets a path for the Web Server to use to communicate back with the connecting browser SUBNET MASK is the IP subnet mask that the Web Server should use to determine whether a connection came from a local network or should be routed on to another network see previous setting All of the IP settings for the Web Server must be on the same subnet for communications to be established between the Web Server and a browser from the Internet Explorer browser you must select Tools Internet Options then click on the Delete Files button check Delete all offline content then click OK to finish the process IMPORTANT When making an update to the Web Server software 22 NEN Web Server User s Manual PN 51990 A2 12 02 03 www PDF Zoo com 3 3 UsinG VERI FIRETM TOOLS FOR CONFIGURATION Veri FireTM Tools is supplied on CD ROM To install the application onto the PC or laptop
68. word first before setting up the user s NWS password and characteristics E Louisville Design Center Microsoft Internet Explorer Ele Edit View Favorites Tools Help MEE Back y gt O A A search Favorites History Ay 3 8 Address 1 http 179 12 86 119 y eo Links Louisville Design Center NWS Explorer Object System Administration Password Configuration Notifier E System Administrateg Auto Point Detect For ANa E Mail Notification System Settings Monitoring Profiles E Node Mapping O Nodes 001 030 O Nodes 031 060 Nodes 061 090 Nodes 091 120 O Nodes 121 150 O Nodes 151 180 Version Information O NUP Port Statistics Summary NOO1 AM2020 NO38 NFS 640 NO82 NFS 3030 How to add a user e type in a new User name and password e retype password in verify field e press the Add button How to select characteristics e select User name e press the Refresh Characteristics button e change the characteristics press the Change Characteristics button How to delete a user e select User name to delete e press the Delete button How to modify a user s password e select User name to User Configuration vet ED Refresh Characteristics Change Characteristics Verifire Read Status Verifire Control Delete Entry Password Configuration O Nodes 091 120 O Nodes 121 150 Nodes 151
69. wser Unmapped The default value the node is either online with no event reporting or there is no device detected at that node address No events or properties will be displayed for unmapped nodes NEN Web Server User s Manual PN 51990 A2 12 02 03 www PDF Zoo com 37 4 3 6 PASSWORD CONFIGURATION Selecting System Administration Password Configuration allows you to create modify and delete system users and their access profiles The system will support up to 128 total IDs The page includes brief instructions on how to set up admin and user profiles The username must be between 3 and 15 characters The password must be between 5 and 8 characters IMPORTANT browser This is where users and their corresponding passwords are created Once a user has been created his her name is added to the drop down selection box in the Characteristics section This is where users are assigned access levels Admin allows System Administration access Verifire Read Status allows the user to access VeriFire for viewing point status information and Verifire Control allows the user to access VeriFire for control and configuration functions 38 www PDF Zoo com NOTE Users cannot access the System Administration menu Only administrators have access to this configuration function To ensure system security when finished with the Web Server exit completely out of your internet NOTE You must set up the VerieFire pass