1. K3 ESM Senior Telecare CSM Security Alarm System Wired Scroll Door Contact If you need to contact more than one wired to the K3 Panel please ensure all of the wired detectors are the same output type Normal Close or Normal Open Types any one of these detectors triggered the panel will alarm If the wired detectors are NC type then the connection must be in series see below NO Type DS Connection NC Detector Connection se E if the wired detectors are NO type then the connection must be in parallel see above 3 Contacting other alarm panel output to K3 Panel The user can connect the other Alarm panel s digital output to the K3 Panel s Digital Input as a wired detector so the user can update its alarm panel as GSM SMS Alarm The connection please reference wired detector connection 7 2 Registering Removing the wireless sensor remote control wireless buttons to the K3 Panel a After registered the wireless sensor remote control or wireless buttons must restart the K3 Panel b The packed wireless detectors registered in the K3 Panel already no need to relearn it again The K3 Panel is learning code more safe and easy to add new wireless remote keys and wireless detectors it supports 3 remote controls and 17 Wireless Zones it can accept one learning code wireless detector in each zone and accept unlimited PT2262 2272 fixed code wireless detectors in each zone The K3 Panel integrated verity pro
2. Serial Number 1 6 A is the identification character of this command Function 1 Code 1 2 3 It is for alarm receiving attribute setting 1 stands for when alarm occurrence the K3 Panel will dial to generate two way voice communication as well as send SMS to this number 2 stands for when alarm occurrence the K3 Panel only send alarm SMS to this number doesn t dial 3 stands for when alarm occurrence the K3 Panel only dial this number to generate two way voice communication doesn t sends SMS Function 2 Code 1 2 3 It is for accessing K3 Panel attribute setting 1 stands for when this number dial to the K3 Panel will be rejected after the first ring meanwhile the K3 Panel will be changed to Stay Mode and not return SMS This is very useful when the user come back home or office to change the K3 Panel to Stay mode with a FREE call from its mobile phone When the user leave the home or store or office dial the K3 Panel again the K3 Panel will be changed to away armed mode and call back once immediately to ensure the armed operation is successful Tips When any number with this value call in the K3 Panel the K3 Panel will change from Stay to Armed or Armed to Stay if the K3 Panel in Disarmed mode then the first time call in will change theK3 Panel to Stay mode 2 stands for when this number dial to the K3 Panel will be picked up automatically and enter into two way voice communication 3 stands for this number cannot
3. Power goes on If the AC Power goes off less than 01 99 minutes then goes on will not send SMS If setup successful will return AC Power Goes off Send SMS After 01 99minutes 6 18Setup Siren Response Feature to Arm Operation Xx ON or xx OFF Default is off Xx ON stands for when armed the K3 Panel by remote control successful the siren will sound 2seconds If setup successful will return Set Ok Xx OFF stands for when armed the K3 Panel by remote control successful the siren will NOT sound If setup successful will return Set Ok if armed or disarmed by phone call or SMS the siren will not make sounds to response 6 19Setup Automatically report Status function XX 00 99 unit is hour stands for the interval time to report the K3 Panel status to the first SMS Alert Number default is 00 means disable report function If no SMS number this function will be invalid The return SMS is the same as by 8 4 Inquiry Status and GSM Module IMEI Code 6 20Setup Temperature Alarm value The K3 Panel can setup high low alarm value when the temperature exceeds the preset value more than ee eee K3 CSM Senior Telecare GOMmM Security Alarm System 10 minutes it will send SMS to alert the users The SMS command is below L stands for the low temperature value can set as minus e g 15 must be 3 digits H stands for the high temperature value can set as minus e g 030 must be 3 digits 6 21 Reset th
4. Supports temperature higher or lower than preset value alert function Big SOS Button easy to push it High quality of voice communication Supports 6 preset call numbers for SMS or Call or both Supports monitoring senior get up bed in time or not Supports wireless fall down detector Supports total 17 wireless detectors or SOS buttons Supports free charge to Arm Stay operation with authorized user phone numbers Inbuilt rechargeable battery inside Easy to use no need to train Easy to installation can put on desk or onto wall VVVV VV VV VV VV WV 5 Installation and Connection Diagram 5 1 Inserting the SIMCard Important Make sure to switch off K3 Panel before inserting or removing your SIM card 1 At the backside of the panel please remove the cover and Slide the SIM card holder in the ee eee K3 CSM Senior Telecare GOMmM Security Alarm System direction of OPEN and insert the SIMCard See below photos 2 Close the SIM card holder and then slide it in the opposite direction of OPEN to lock it See above photo 5 2 Contacting the Siren hooter The user can connect one 9 12V rated siren or hooter to the K3 Panel s siren output once alarm occurrence this output ports will start the siren or hooter to make sounds The positive of the siren connect to the Siren port and the negative of the siren contact to the Siren port Generally the siren wire marked red color and black
5. access the K3 Panel by dial in will be hang up Nor listen neither change to Stay or Arm Mode Telephone Number authorized number max 18 characters E g if you want to setup 13512345678 as the third authorized number and the password is 1234 country code is 0086 when alarm occurrence this number can receive both SMS and incoming from the K3 Panel when dial to the K3 Panel from this number can change the K3 Panel to Stay or Armed mode Then you can send 12343A1 1 008613512345678 to the K3 Panel Will return K3 ESM Senior Telecare CSM Security Alarm System Tell Empty Tel2 Empty Tel3 008613512345678 1 1 Tel4 Empty Tel5 Empty Tel6 Empty Tips The K3 supports wireless detector battery low voltage alert function if detected the wireless detector battery is low voltage the K3 will send SMS zone name Low Voltage Alert to the first SMS number At present only PIR 100B and EM 90 supports low voltage alert function 6 4 Inquiry the Authorized number After received this command the K3 Panel will return the SMS as abovementioned E g If you want to know the authorized number list and the password is 1234 then you can send to check It 6 5 Remove the Authorized Number Please overwrite it with another number that you wish to change it or removed it by SMS Command 6 6 Modify the wired zone dry contact digital input type Default is NC Modify the digital input to NC Normal Close type if
6. is Password SMS Command i e if the password is 1234 then you can send to arm 1234BB to disarm the AA EE must be Caps Lock K3 CSM Senior Telecare CSM Security Alarm System 1 Brief introduction The K3 is a brevity fashion and neat design GSM Security Alarm System it is not only a security alarm system but also a senior telecare system The User can send SMS text to control it and received SMS text from it while something happened The K3 includes multi functions and high reliability it is special for Residential areas business area commercial area office factory industrial area senior emergency call senior daily activation and communication and other Varity applications It integrated high performance GSM Module and MCU inside and with innovative and experienced functions and features to meet the required and potential demands in the worldwide markets When it used as a GSM Security Alarm system the user can call in to Arm Stay operation with a free charge from its phone and plus different wireless detectors to protect its assets When it used as the senior telecare system it can be used as a GSM Emergency call system and also can dial and send SMS to preset numbers while Fall Down Push SOS Button Hasn t got up bed in time carbon monoxide leak or intrusion At this period the aging trend is very serious in all countries and lots of seniors living alone They are need urgently help in sometime also
7. worry about death while sleep or fall down and nobody know it The LCD can display the current time what sensor activated and current indoor temperature 2 Safety Directions Safe Startup Do not use K3 Panel when using GSM equipment is prohibited or might bring disturbance or danger Interference All wireless equipment might interfere network signals of K3 Panel and influence its performance Avoid Use at Gas Station Do not use K3 Panel at a gas station Power off K3 Panel when it near fuels or chemicals Power it off near Blasting Places Please follow relevant restrictive regulations Avoid using the device in blasting places Reasonable Use Please install the product at suitable places as described in the product documentation ee eee K3 CSM Senior Telecare CSM Security Alarm System Avoid signal shielded by covering the mainframe Use Qualified Maintenance Service Maintenance can be carried out only by qualified maintainer Package A Item GSM Alarm Pane SMAlamPanel Wireless Fall Down Detector Wireless Door Contact 1 AC DC Adaptor __ Wireless PIR Motion Detector 1 Optional Accessories Wired Sensors or wireless detectors PIR Motion Sensor Glass Break Sensor Magnetic Window Sensor Temperature Sensor Infrared Beam Fence Vibration sensor Siren 4 Mainly Features Brevity Fashion Neat design LCD display current time which detector activated indoor current temperature
8. 4 Hours emergency zones triggered will cause alarm all of the other zones triggered will not cause alarm Usually for maintain or other special requirements 3 Alarm Occurrence 1 When alarm occurrence the K3 Panel will send out Alarm SMS Content firstly then automatically dial the authorized numbers one by one if picked up the call the K3 Panel will stop to sound and enter to listen mode can not speak If nobody picked up or rejected the K3 Panel will dial all of the authorized numbers 3 times in cycle then stop to dial any more Meanwhile the K3 Panel will enter to previous status 2 Only the zone attribute code setup as 0 1 2 3 4 will cause the siren sound while alarm occurrence And the siren will sound about 20 seconds then interrupt about 2 seconds the time according to the setting 3 Once any zone triggered the corresponding LED will always on till Disarm or Restart the K3 Panel mm ee K3 CSM Senior Telecare CSM Security Alarm System 8 1 Operation by Remote Controls Press the button k on the remote key or Press the wireless or wired Arm button the K3 Panel enters arm status delay time according to the setting Under this status any detector triggered the K3 Panel will alarm if answered the call the siren will stop and can listen in the alarm area by phone If you use the remote control to arm the K3 Panel you press the Arm Button then press the SOS button within 2 Seconds the K3 Panel will enter
9. APS LOCK If the password incorrect will not return any SMS 9 When alarm occurrence and in the delay alarm time the buzzer will alert by DIDI sounds once the delay timeout the buzzer will stop to sound 10 After you reset or learning remote control or wireless sensors please remember to restart it otherwise can not work properly 11 The SMS commands that you will certainly use in the K3 Panel are the following 6 1 Setup K3 Panel SIMCard Number System Time The K3 Panel can automatically setup the system time by itself no need to setup it by manual any more But should setup the SIMCard number firstly This parameter must setup again after changed SIMCard or new unit or reset to factory default setting See below Inserted in the K3 panel is 008613501111111 then can send K3 CSM Senior Telecare CSM Security Alarm System 1234L008613501111111 to the K3 panel Inquiry the setting pwd LL 4 after the K3 Panel received will return MyTel XXXXXXXXXXX 6 2 Setup New Password if successful the unit will return new password This is the New Password please remember it The password is 4digits For example the original password is 1234 you want change it to 6666 then you can send the command below 6 3 Setup Authorized number lf you GSM Operator use different number format for SMS and Dial out then please see Notice 6 must setup as includes country code and not includes country code two formats
10. Armed mode immediately no delay Press the button mi on the remote control or press the wireless button the K3 Panel disarms immediately Under this status any detector triggered the K3 Panel will not alarm Except the zone attribute is the 24 Hour Emergency Zones Press the button on the remote control or the wireless or wired Stay button the K3 Panel enters Stay Partial Armed status the zones attribute had been set as outer zone and 24 hours emergency zone triggered will cause alarm but the zone attribute had been set as inner zone triggered will not cause alarm Press Emergency button SOS on the remote control The K3 Panel will cause emergency alarm The siren will not sound but will alert the pre set phone number immediately The Alarm SMS Content is Remote Key SOS Help The Alarm SMS Content for the remote control SOS button can not be modified 8 2 Armed or Stay WITH a FREE call from authorized phone The K3 Panel supports armed or Stay by a free call from authorized phone after you setup the authorized number Function 2 Code as 1 then the user can use this phone number to Arm or Stay the K3 Panel by free charge call in Please reference 6 2 Setup Authorized Number to setup it When the K3 Panel in Disarmed mode any number with the authorized right call in will change it to Stay mode When the K3 Panel in Stay Mode any number with the authorized right call in will change it to Armed Away mode and cal
11. allation Schedule Before install the K3 Panel please write down the installation plan firstly it is very useful for saving your test and installation time After installed successful then tear down this Schedule for review in further ee Ee eee K3 CSM Senior Telecare CSM Security Alarm System K3 Panel Installation Schedule Default Value of Zones User Defined Value of Zones Sensor Place E g SMS Alarm Content Attr SMS Alarm Content Attr ae Windows Description Code Code 00 Wiredzonearm 2 o po Entrancearm o f O ooo d Wireless Zone 11 Spot a Alarm Gas Leakage Alarm Panic Help Alarm Emergency Silent Alarm Monitoring Area No 17 I Fixed Action Alarm K3 Panel Authorized Number Schedule SIMCard Number in the K3 Panel Authorized Type Phone Number Alert when Alarm Occurrence Access the K3 Panel Serial Number Notice Please mark V if for enable and X for disable K3 CSM Senior Telecare GOMmM Security Alarm System Table 2 K3 Panel Program and Operation SMS Command List K3 Panel SMS Command List Caps Lock Function Description SMS Command Format SMS Command Format Example Arm Away Switch On The Siren Switch OFF the Siren Inquiry Status GSM Signal IME Setup New Password pwd Serial Number A Function 1 Code Function 2 7 Setup Authorized number code Telephone Number See 6 3 Inquiry the Authorized number Remove Authorized Number o
12. color the red color is positive and the black color wire is negative See below 5 3 Contacting the AC DC Power Supply Please contact the 12VDC to the K3 Panel the Positive of the 12VDC connect to the PWR the negative of the 12VDC please contact to PWR Generally the red color from the AC DC Adaptor is Positive and the black color is negative The AC DC Adaptor is 12V1A or 12V2A see above mentioned 5 4 Switching on off the K3 Panel After finished all of the connections please plus the AC DC Adaptor to external AC Power socket and switch the PSW Switch to ON side to switch on the K3 Panel See abovementioned 5 5 Amounting the K3 Panel The K3 Panel should be installed in a place where the intruders cannot discover it And the GSM Signal covered well Also the user can see the LED easily to know what happened and what is the status of the K3 Panel eee eee E oe K3 CSM Senior Telecare GOmM Security Alarm System 6 Settings The K3 Panel is an advanced multifunctional programmable controller The user can program it by SMS Commands for various application requirements When power on the K3 Panel will display meanwhile it will automatically registering the SIMCard to GSM Network after the SIMCard registered successful will display GOOD If more than 90Seconds still hasn t registered successful it will display ERRO if no SIMCard detected it will display and after 60 seconds it f
13. ctions The user can operate the K3 Panel by Android Apps For Android Apps please download from our official website GSM Alarm amp SOS Call System K3 CSM Senior Telecare CSM Security Alarm System 3 1 59 PM GSM Alarm Controller Set the phone No first 9 Technical specifications Rated Voltage 12VDC 1A 12V 14VDC Standby Consumption 30 35mA Not charging battery Working Consumption 400mA Siren working Working temperature 10 C 60 C Storage temperature 20 C 60 C Relative humidity 10 90 No condensation GSM frequency 850 900 1800 1 900MHz Communication protocol GSM PHASE 2 2 include data service Wired Zones 1 Dry Contact NC or NO Wireless Encode Learning code compatibles fixed encode Wireless Zone 17 can accept one learning code wireless detector in each zone and accept unlimited PT2262 2272 fixed code wireless detectors in each zone Remote Control 3 Wireless Frequency 433Mhz Wireless Distance 100m in open air Backup Rechargable Battery 3 7V 900 1200mAH lithium batteries Net Weight 0 50Kg 10 Warranty 1 This system is warranted to be free of defects in material and workmanship for one year 2 This warranty does not extend to any defect malfunction or failure caused by abuse or misuse by the Operating Instructions In no event shall the manufacturer be liable for any alarm system altered by purchasers 11 Affix Table Table 1 K3 Panel Inst
14. e If setup successful will return Send Operation Code to 1 Number H is the identification character of this command Pe Ee eee K3 CSM Senior Telecare GOmM Security Alarm System Tips f enable this function when the Authorized Number that Function 2 Code 1 can dial in to change the status from Stay to Arm call in the K3 Panel will send SMS to the 1st Authorized Number If any other number armed or disarmed the K3 Panel it will send SMS to the 1st Authorized number The SMS content is Armed By Telephone number or Disarmed by Telephone number Disable this function SMS Command is 6 16 Required the K3 Panel callback If send successful the K3 Panel will call back the user immediately It is special for the Authorized Number that Function 2 Code 1 can dial in to change the status from Stay to Arm to two way voice communication 6 17 Setup External Power Status Alert Feature Default is 30 minutes If send successful will return SMS M is the identification character of this command Xx 00 99 Default is 30 Unit is minute Xx 00 stands for when external AC Power goes off will send SMS to all authorized numbers or send SMS when AC Power goes on If setup successful will return AC Power Goes off Send SMS Immediately Xx 01 99 stands for when external AC Power goes off more than 01 99 minutes will send SMS Power Goes off 01 99minutes to all authorized numbers or send SMS IAC Power Goes ON when AC
15. e K3 Panel to Factory Default The K3 Panel can be reset to the factory default by following operation Switch off the K3 Panel then press the UP and Down Button at the same time See below Switch on the K3 Panel about 3Seconds later the K3 Panel will display RSE then loose the RESET button means the reset operation successful And please restart the K3 Panel again O i RESET SET e After this operation all the registered wireless detectors and wireless panic buttons and Remote Controls will be removed from the K3 Panel and all of the settings will be reset to the factory default 7 Zone Settings and Connections 7 1 Contacting the Wired Sensor or Other Alarm Panel to K3 Panel The K3 Panel equips one dry contact Normal Close or Normal Open type digital input port the user can connect the wired detector or other alarm panel to it When the digital input triggered by wired detectors or other alarm panel it will alarm 1 Setup the wired detector type SMS Alert Content and zone attributes Please refer to 6 7 6 10 2 Contacting the wired Detector to K3 Panel The wired detector has two connectors please contact one of them to the DIN port another contact to the GND port And setup the Digital input be the correct NC or NO type by SMS Commands Tips if you don t know the NC or NO type of the Detector please try to change the setting to NC or NO type by SMS Commands to after you finished connections E E a
16. fault is 180seconds If setup successful will return Siren ON xxx Seconds E is the identification character of this command Xxx 000 999 unit is second 3 digits Default is 180 seconds E g if you want to setup the siren sound 60seonds when alarm occurrence and password Is 1234 then please send Tips Only the zone attribute code setup as 0 1 2 3 4 will cause the siren sound while alarm occurrence And the siren will sound about 20 seconds then interrupt about 2 seconds 6 13Setup the Alarm Delay Time Default is O00second If setup successful will returniAlarm Delay xxx Seconds F is the identification character of this command Xxx 000 999 unit is second 3digits Default is 000 second Tips Only the zone attribute code setup as 1 2 3 will delay to cause alarm while alarm occurrence 6 14Setup the Arm Delay Time Default is 30seconds If setup successful will returnAArmed Delay xx Seconds G is the identification character of this command Xxx 00 99 unit is second 2digits Default is 30 seconds Tips 1 Only the zone attribute code setup as 1 2 3 will delay to enter into Arm mode when Arm the K3 Panel 2 If Armed the K3 Panel by remote control after press the Armed Button and press its SOS button within 2 Seconds the K3 Panel will enter into Armed Mode immediately will not delay 6 15Enable to Alert the first Authorized Number when other number armed or disarmed the K3 Panel Default is Disabl
17. grammable zone attributes includes Away normal At House or Stay Entrance Zone 24 Hours Sound Zone 24 Hours Silent Zone Local Zone SOS Zone Door Bell Zone and Monitoring movement zone The SMS Alarm Content of each zone is programmable by user through SMS Commands Please follow below step by step to learning the wireless detectors or remote controls or wireless buttons to the expected zones Ee ee K3 CSM Senior Telecare CSM Security Alarm System 1 Writing Installation Schedule Please write down your schedule in below table it will make you clearly what sensor in which zone and with what attribute e g using a wireless door contact for entrance using the photoelectric beams for wired zone in outdoor fence and using a wireless smoke detector for fire alarm and so on Please see the Affix table 2 Setup the wireless detector SMS Alert Contents and zone attributes Please refer to 6 8 6 11 3 Enter Leaning Mode At standby mode press the SET button for 3 seconds will enter learning mode display R1 then loose the button Press the SET button for 3 seconds again will exit learning mode After learned detectors successful it will alert by a long Di sounds a When learning one detector to the K3 Panel the other wireless detectors must be in OFF status otherwise will confuse the learning operation b In learning mode you can press the Up or Down buttons to choose the previous or next zone 4 Learning
18. i mM GSM Security Alar e GSM Senior Telecar K3 Getup Bed In time CO Fire WET ts Leakage _ Temperature jo UJ CU U Ea U K3 CSM Senior Telecare CSM Security Alarm System index 1 Brief introduction 6 15Enable to Alert the first Authorized Number 10 2 Safety Directions 6 16Required the K3 callback 3 Standard Packing list 6 17Setup External Power Status Alert Feature 4 Mainly Features 6 18Setup Siren Response Feature 5 Installation and Connection Diagram 6 19 Setup Automatically report Status function 5 1 Inserting the SIMCard 6 20 Setup Temperature Alarm value 5 2Contacting the Siren hooter 6 21 Reset the K3 Panel to Factory Default 5 3Contacting the AC DC Power Supply 7 Zone Settings and Connections 9 4Switching on off the Panel 7 1Contacting the Wired Sensor 5 5Amounting the Panel 7 2 Registering Removing the wireless sensor remote 6 Settings control wireless buttons to the K3 Panel 6 1Setup K3 Panel SIMCard Number 8 Operating Instructions 6 2Setup New Password 8 1Operation by Remote Controls 6 3Setup Authorized number 8 2Armed or Stay WITH a FREE call 6 4Inquiry the Authorized number 8 3SMS Commands for Arm or Disarm or Switch 6 5Remove the Authorized Number On Off Siren 6 6Modily the wired zone type 8 4Inquiry Status and GSM Module IMEI Code 6 7Modify the SMS Alarm Content 8 510S App and Android Apps Instructions 6 8Inquiry the SMS Alarm Content Setting 9 Techn
19. ical specifications 6 9Setup the Zone Attribute 10 Warranty 6 10Inquiry the Zone Attribute 11 Affix Table 6 11Setup Zone17 Monitoring Zone Table 1 Installation Schedule 6 12Setup the Siren Sound time Table 2 SMS Command List 6 13Setup the Alarm Delay Time 6 14Setup the Arm Delay Time This handbook has been designed as a guide to the installation and operation of K3 Panel Statements contained in the handbook are general guidelines only and in no way are designed to supersede the instructions contained with other products We recommend that the advice of a registered electrician be sought before any Installation work commences The manufacturer its employees and distributors accept no liability for any loss or damage including consequential damage due to reliance on any material contained in this handbook The manufacturer its employees and distributors accept no liability for GSM Network upgrading or SIMCard upgrading due to the technology specifications contained in this handbook SMS Command List SMS COMMAND Functions amp Actions Very Important AA To arm the K3 Panel in this mode any detector triggered will alarm MACEM OTs BB To disarm the K3 Panel in this mode detector triggered will not Installation alarm Schedule at Page To switch ON the Siren output 20 before To switch OFF the Siren output programming it Inquiry the K3 Panel Status and GSM Module IMEI Code The commands should plus Password the format
20. inished registering And display the default time and temperature in turn 1 The default Password is 1234 2 All the settings are through SMS commands please edit the below SMS commands in your cell phone then send to the K3 Panel Tips The K3 Panel cannot support PIN Code Protected SIMCard Please ensure you have disabled the PIN Code of the SiMCard otherwise can not register GSM Network successful 3 You can program the K3 Panel with SMS commands using your phone It is safe to do so because in addition to the fact that other people may not know the number of the SIM inserted in it we also use a Password that makes it impossible for anybody who doesn t know it to access the system by chance 4 Remember that commands must be CAPITAL LETTERS It is PWD not pwd CAP not Cap etc Don t add spaces or any other character 5 The pwd in the commands is means the password when you use it please in stand of it by the digital number 6 While setup phone numbers please try to plus the country code or remove country code E g 0086 13500001111 or 13500001117 7 Please write down the setting list in a paper for review in further please see the affix table at the last page and tear down from this instruction for review 8 Ifthe command is incorrect the K3 Panel will return SMS Format Error Please check Caps Lock in Command Or other warning message So please check the Command or check the input is in ENGLISH INPUT METHOD and C
21. l back immediately as confirmation Armed When the K3 Panel in Armed Away Mode any number with the authorized right call in will change it to Stay Mode This function is very useful while you leave or come back home 8 3 SMS Commands for Arm Away or Disarm or Switch On Off Siren The User can Arm Disarm Switch on or off the siren by sending SMS to the K3 Panel The SMS Commands are below ee Sn Te Tr eee K3 CSM Senior Telecare CSM Security Alarm System The system will carry out the commands immediately with no delay after the K3 Panel receive this SMS command 8 3 1 Armed Away Example 1234AA XXXXAA xxxx Stands for the password 4 digits Return SMS Armed When the Password is 1234 8 3 2 Disarm Example 1111BB XxxxBB xxxx Stands for the password digits Return SMS Disarmed When the Password is 1111 8 3 3 Switch On the Siren Example 1111CC XxxxCC xxxx Stands for the password 4 digits Return SMS SICONA When the Password is 1111 8 3 4 Switch OFF the Siren Example 1111DD xxxxDD xxxx Stands for the password 4 digits Return SMS Siren OFF When the Password is 1111 8 4 Inquiry Status and GSM Module IMEI Code xxxxEE xxxx stands for the password 4 digits Return SMS Armed or Disarmed AC Power ON or AC Power off GSM Value is 17 or other value IMEI Code XXXXXXXXXXXXXXXXXX 8 5 Android Apps Instru
22. ne zone attribute can be setup in one SMS Command but don t exceed the SMS character limitation e g if want to setup the attributes of wired zone 01 wireless zone O2wireless zone 03 wireless zones 08 wireless zone the password is 1234 then please send 1234D00 0 D01 1 D02 4 D03 6 D08 94 6 10Inquiry the Zone Attribute If send successful will return the zone attributes 00 1 01 0 02 2 6 11Setup Zone 17 Monitoring Movement Zone The K3 Panel supports monitoring movement zone it is special for monitoring senior get up bed in time or not if not get up in time the K3 Panel will arise alarm This is very useful for monitoring the senior get up bed or not while her him living alone Please follow below K3 CSM Senior Telecare GOMmM Security Alarm System a Leaning a Wireless PIR Motion detector to zone 17 and install it at the bedroom entrance b Setup the movement period time The SMS command is jpwd Q Start time End Time Example 1234Q06 00 09 00 if at this period the senior hasn t gone out the bedroom the PIR motion detector will not be activated by the senior it will arise an alarm to indicate that the senior hasn t got up the bed The K3 panel will send preset SMS and dial the authorized numbers c If you want to disabled the monitoring zone please send jowd Q00 00 00 00 to the K3 Panel Notice If the K3 panel at AWAY mode this function will automatically disabled 6 12Setup the Siren Sound time De
23. onitoring senior get up bed in time or not Attribute Code 0 9 stands for how does the K3 Panel will performance when this zone activated 0 stands for entrance when armed the K3 Panel this zone will delay 30 seconds to enter into Armed mode for leaving the home or office When come back the home or office will delay 20 seconds to alarm in order to the user can change it to Stay or Disarm the K3 Panel 1 stands for outer zones in Armed or Stay mode when triggered will cause alarm 2 stands for inner zones in Stay mode if triggered will not cause alarm in Armed mode if triggered will cause alarm 3 stands for spot alarm zone in Stay mode if triggered only cause the siren to sound Neither dial out nor send SMS out in Armed mode if triggered will cause alarm 4 stands for 24hours emergency zone with sounds In any mode if triggered will cause alarm immediately with siren sounds 5 stands for 24hours emergency silent zone In any mode if triggered will cause alarm immediately the siren will not sound 6 stands for Armed Buiton trigged it to make the K3 Panel change to Arm Mode 7 stands for Stay Button triggered it to make the K3 Panel change to Stay Mode 8 stands for Disarm Button triggered it to make the K3 Panel change to Disarm mode 9 stands for door bell button triggered it to cause the buzzer to sound 8times Tips 1 When the attribute code setup as 6 7 8 9 the siren will not sound 2 More than o
24. the Wireless Detector or Remote Control to K3 Panel When the K3 Panel enter the learning mode it will display R1 stands for waiting to learning the first remote control At this time can press any button of the first remote control the K3 Panel will learn the code automatically If successful it will alert by long Di sounds means the remote control was learned to the first position press Down button to learn the second remote control If the position was occupied by a remote control already it will display R1USE At this time you can press the SET button again to remove it and lean a new remote control to replace it If you dislike to learn any remote control to this position then please press down button to next zone position By the same way you can learn or remove the wireless detectors to the K3 panel a Remote Control and Wireless Detectors activated method For remote control press any key then can activate it no need to press all of them The wireless door contact can be triggered by dispatch the two parts when installed battery inside The wireless PIR Motion Detectors can be triggered by pass though its front when switched on The wireless panic buttons can be triggered by press its button The wireless gas leakage or wireless water leakage and wireless smoke detector equips Test Button press the Test Button then can trigger them The other wireless detectors please reference its user instructions b When the
25. the sensor you used with this unit is NC then you should set the unit as NC type will return Zone00O NC Modify the digital input to NO Normal Open type if the sensor you used with this unit is NO then you should set the unit as NO type will return Zone00 NO 6 7 Modify the SMS Alarm Content If setup successful will return the SMS Alarm Content B is the identification character of this command Zone Number 00 17 00 stands for the wired zone 01 17 stands for the 17 wireless zones SMS Alarm Content When alarm occurrence the K3 Panel will send the SMS Alarm Content to the authorized numbers by SMS Max 40 characters can not be empty otherwise the K3 Panel will return SMS Alarm Content cannot be set as empty E g if you want to receive SMS Alarm content of the wireless zone 05 is intruder breaking the windows and password is 1234 then you can send SMS 1234B05 intruder breaking the windows 6 8 Inquiry the SMS Alarm Content Setting K3 CSM Senior Telecare GOMmM Security Alarm System If setup successful will return the zone number s SMS Alarm Content 6 9 Setup the Zone Attribute If setup successful will return the zone number s Attribute code D is the identification character of this command Zone Number 00 16 00 stands for the wired zone 01 16 stands for the 16 wireless zones Notice Zone 17 was assigned as the monitoring movement zone can not change the attribute special for m
26. to its position to in stand of it or remove it directly If you want to remove the wireless detector in specified position please move to that zone position then press SET button it will Display R1 or xx stands for removed the wireless detector already 6 Some popular wireless detectors i 272 an an an m m MM m 1 vo E e PIR Motion Detector Dual Element PIR Motion Detector Ceiling PIR Motion Detector Fall Down SOS Button l a fs Door Contact Garage Door Contact Photoelectric Beams Detector Microwave Dual PIR Detector a K3 ESM Senior Telecare GOmM Security Alarm System i i NGC t i O 3 ug nana oa WWW Gas Leakage Detector Smoke Detector Necklace Waterproof Panic Button Emergency Button Wireless Signal Repeater 8 Operating Instructions 1 The user can arm disarm Stay Partial armed by Remote Control Wired Button Wireless Button Dial in and SMS Another the user can switch on or off the Siren by SMS Commands 2 Mode explanation Armed Away In this mode any detector triggered will cause alarm It be used for away the home and need to protect all of the home or office or store etc Stay Partial armed at home in this mode only the outer zones and emergency zones triggered will cause alarm the inner zone triggered will not cause alarm It be used for partial armed e g some people at home and need to monitoring the outer security Disarmed Except the 2
27. wd A pwd SerialNumber A pwd NC owd NO pwd B ZoneNumber SMS 1234B05 intruder Alarm Content breaking the windows pwd B Zonenumber 1234B01 owd D Zonenumber Attrioute Code See 6 9 owd D Modify wired zone type as NC Default is NC Modify wired zone type as NO Modify the SMS Alarm Content Inquiry the SMS Alarm Content Setup the Zone Attribute Inquiry the Zone Attribute Setup the Siren Sound time owd E xxx 1234E060 Default 180S pwd F xxx 1234F999 Default 000S pwd G xx 1234G09 Default 30S 17 Setup the Alarm Delay Time Setup the Arm Delay Time Enable Alert the 1st Authorized owd H Disable Alert the 1st Authorized pwd J Default Required to callback AC Power Goes OFF Alert at once AC Power Goes OFF Alert after 01 99 minutes Siren Response to Arm Operation Siren NOT Response to Arm Operation Automatically report Status function Setup K3 Panel SIMCard Number Setup Zone 17 Monitoring Movement Time period Disable Zone 17 pwd Q00 00 00 00 Setup Temperature Alarm value pwd 1 L H pwd K pwd M 00 owd M xx Default is 30minutes pwd ON Default owd OFF 00 99hours default is 00 d T anesthe means disabled 27 owd L SIMCard Number pwd Q Starttime EndTime o
28. wireless PIR Motion detection is PIR 100B please remember setup the PIR 100B to Test Mode while learning to the K3 Panel after learned to the K3 Panel then please setup to Normal Mode by change the Black PIN Jumpers in the PCB please see the PIR 100B user manual c The differences of PIR Motion Curtain Motion and Ceiling motion detector are the detection direction areas d When the wireless Detectors is PT2262 fixed IC code please setup its wireless code by use some Jumpers to configured it randomly recommend 4 6 jumpers see below 1 Removing the back cover carefully 2 Locate the IC boards black jumpers labeled AO A7 and DO D3 please see below figure 3 Configured the AO A7 and DO D3 different from each wireless detectors If configured the AO A7 and DO D3 a Fu K3 ESM Senior Telecare CSM Security Alarm System are the same the system will treat them as the same one sensor So if you want to add more than one wireless detector to any zone please configure the jumpers as the same in the wireless detectors 4 Also please check the Resistors value is 3 3M Ohm there re 3 Jumpers 1 5M 3 3M and 4 7M if you select incorrect value the wireless distance usually very short or cannot learn to the K3 Panel L N 0 H N 1 L N H 2 r RAIES DENTE fr LI 5 Removing wireless accessories After learned the wireless accessories to the K3 Panel it can be replaced by learning a new wireless detector
Download Pdf Manuals
Related Search
Related Contents
Handbuch echo-screen TDA - Mack Medizintechnik GmbH Xerox Printer FS 3270 User's Manual Akasa AK-TOX-02BK computer case Isomac Brio Espresso Machine Bluetooth® Stereo Headset Kit for iPod Lanternes chinoises et feux d`artifice : quelques conseils pour une Sanukehl Strep D5 Injlsg_lg PanaFlow™ MV80 et MV82 - GE Measurement & Control Copyright © All rights reserved.