1. UDM Ultrasonic Distance Measure Instruction Manual As of August 2011 ALL ARTWORK PICTURES AND TEXTS ARE COVERED BY OUR COPYRIGHT THEY MUST NOT BE COPIED FOR REPRODUCTION E G ON CD ROM DISKS OR INTERNET SITES OR USED IN THEIR ENTIRE FORM OR IN EXCERPTS WITHOUT OUR PREVIOUS WRITTEN AGREEMENT IF YOU ARE DOWNLOADING PDF FILES FROM OUR INTERNET HOME PAGE FOR YOUR PERSONAL USE MAKE SURE TO CHECK FOR UPDATED VERSIONS WE CANNOT TAKE ANY LIABILITY WHATSOEVER FOR DOWNLOADED FILES AS TECHNICAL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE 1 Contents 1 Contents 2 2 Safety Instructions and Legal Disclaimer 4 2 1 Safety instructions 4 2 2 Disclaimer 4 5 ie est ee de 5 3 General Description 7 3 1 ARRI Order numbers 9 10 5 Operation of the UDM 11 5 1 Switching 11 5 2 Controls and Status LEDS anne 11 5 3 Operation Settings 12 54 Parameter Settings 12 5 5 Depth of Field and Focus Tracking 13 6 Specifications 14 7 ARRI Service 15 This page is left intentionally blank 2 Safety Instructions and Legal Disclaimer 2 1 Safety instructions Do not use accessories or attachments not re
2. be sure to read and understand all respective instructions The ARRI Wireless Lens Control System is only available for commercial customers The customer grants by utilization that the ARRI Ultrasonic Distance Measure UDM or other components of the system are only deployed for commercial use Otherwise the customer has the obligation to contact ARRI preceding the utilization While ARRI endeavors to enhance the quality reliability and safety of their products customers agree and acknowledge that the possibility of defects thereof cannot be eliminated entirely To minimize risks of damage to property or injury including death to persons arising from defects in the products customers must incorporate sufficient safety measures in their work with the system and have to heed the statuted canonic use No part of this document may be copied or reproduced in any form or by any means without prior written consent of ARRI ARRI assumes no responsibility for any errors that may appear in this document The information is subject to change without notice For actual design in refer to the latest publications of ARRI data sheets or data books etc for the most up to date specifications Not all products and or types are available in every country Please check with an ARRI sales representative for availability and additional information ARRI or its subsidiaries does not assume any liability for infringement of patents copyrights or other in
3. 3 8 support on both units Connect the Display to the Sensor Unit using the blue labeled cable Choose the applicable supply cable either for ALEXA ARRICAM ARRIFLEX 435 435Advanced 435Xtreme 416 235 camera or the optionally available UMC 3 cable You may create custom supply cables at your own risk Refer to chapter 6 for detailed information 4 2 LCS Setup Depth of Field Display and Focus Tracking Using suitable cameras and accessories the UDM provides the operator with actual Depth of Field information on the LDD FP and controls automatic focus tracking when required The UDM sends the distance information repeatedly in a serial data stream to the connected unit Applicable units are ARRI cameras providing a LDD connector and built in lens motor drives like the ALEXA Plus the ARRICAM ST LT equipped with a Lens Data Box and an unit incorporating a LDD FP connector an ARRIFLEX 435 Advanced Xtreme with FEM 2 or an ARRIFLEX 416 plus Alternatively a UMC 3 will also interface the UDM data to an LDD FP in non ARRI set ups e g video camera usage As the LDD FP provides the complete UDM information the Display Unit may be disconnected after parameters have been set Applicable Cameras and Accessories Cameras ARRICAM Studio Studio Lens Data Box Studio Readout ARRICAM Lite Lite Lens Data Box Lite Frame Glow or Remote Control Station with cable KC 65 or KC 69 ARRIFLEX 435Advanced Xtreme FEM 2 ARRIFLEX 416pl
4. M Exp 260m Raw Om Batt 243V N 4 6 290 1 78 Filter the gate 264 m UP tracks focus 24 mm T4 Typical LDD FP image indicating UDM CTM active measured distance green dart and numeric value Depth of Field bar graph and numeric value 13 6 Specifications Operating temperature 20 to 50 C 4 to 122 F Operating voltage 10 t0 30 V DC 12 24V nominal ARRICAM compotible Typ current consumption 0 024A 24V 0 040A 12V Dimensions h w d with connector Display Unit 83 75 32 mm 3 3 2 9 1 3 Sensor Unit 73 74 91 mm 2 9 2 9 3 6 in Weights Display Unit 1409 5 oz Sensor Unit 120 g 4 2 oz Power connections pin GND 4 Vbat suitable connector ARRI order 05 21182 0 LEMO FHJ 0B 304 CYMD52Z or equivalent Declaration of Conformity We Manufacturer ARRI CINE VIDEO GERATE GmbH Pottendorferstrasse 25 27 3 2 1 A 1120 Wien declare that the product Ultrasonic Distance Measure UDM is in conformity with DIN EN 61326 1 2006 10 DIN EN 55011 2003 08 Group1 ClassB DIN EN61000 4 2 2001 12 DIN EN61000 4 3 2003 11 DIN EN61000 4 4 2002 07 Date Signature 2007 05 27 2 P Ing Walter 7 ARRI Service Germany USA Arnold amp Richter Cine Technik GB T rkenstra e 89 D 80799 M nchen Deutschland phone 49 0 89 3809 0 fax 49 0 89 3809 1245 fax service 49 0 89 3809 1793 e m
5. M complete The package includes K2 65144 0 Cable UDM UMC 3 1 5m 5ft connects UDM Sensor Unit t0 UMC 3 AUX 2 65130 0 UDM Sensor Unit K2 65261 0 Cable UDM ALEXA 1 5m 5ft K2 65131 0 UDM Display Unit connects UDM Sensor Unit to ALEXA EXT K4 65655 0 Cable UDM Sensor 1 5m 5ft K2 65240 0 Cable UDM RS 1 5m 5ft connects Sensor Unit to Display Unit connects UDM Sensor Unit to ARRI RS connector K5 65999 0 UDM User Manual EN K2 65262 0 Cable UDM PSC 0 7m 2 5ft connects UDM Sensor Unit to PSC cables PSC Cables Optional Accessory ARRI order no Description Length connects to Function K2 65206 0 PSC XLR3 1 5m 5ft 24volts battery Power supply only K4 65656 0 Cable UDM CAM 1 5m 5ft K2 65207 0 PSC XLRA 1 5m 5ft 12volts battery Power supply only connects UDM Sensor Unit to ARRICAM CAC K2 65208 0 PSC DTAP 0 6m 2ft Anton Bauer D Tap socket Power supply only K2 65209 0 PSC HI12 0 6m 2ft Hirose 12pin socket Power supply only K4 65672 0 Cable UDM 435 1 5m 5ft K2 65210 0 PSC FI11 0 6m 2ft ARRIFLEX 435 SONY FF35 Power supply only connects UDM Sensor Unit to K2 65211 0 PSC RS 0 6m 2ft ARRI RS socket Power supply only ARRIFLEX 435 Advanced Xtreme or K2 65212 0 PSC FI2 1 5m 5ft ARRI OBB 2 battery Power supply only ARRIFLEX 416 PLUS K2 65213 0 PSC LCS 0 6m 2ft ARRI LCS bus Power supply only 4 Setup 4 1 Standard Setup Distance measurement only Fasten the UDM units in convenient places on or around the camera using the
6. ail service webmaster arri de ARRI Camera Rental T rkenstra e 89 Italy D 80799 M nchen Deutschland phone 49 0 89 3809 1240 fax 49 0 89 3809 1798 e mail mjahn arri de ARRI Inc East Coast 617 Route 303 Blauvelt NY 10913 1123 phone 1 845 353 1400 USA fax 1 845 425 1250 e mail arriflex arri com ARRI Inc Canada West Coast 600 North Victory Blvd Burbank CA 91502 1639 USA phone 1 818 841 7070 fax 1818 848 4028 e mail brussell arri com ARRI GB Limited 2 Highbridge Oxford Road Uxbridge Middlesex UB8 1LX England phone 44 0 1895 457 000 fax 44 0 1895 457 001 e mail sales arri gb com ARRI Italia S R L Viale Edison 318 20099 Sesto San Giovanni Milano Italia phone 39 02 262 271 75 fax 39 02 242 1692 e mail info arri it ARRI Italia S R L Via Placanica 95 00040 Morena Roma Italia phone 39 06 79 89 02 1 fax 39 06 79 89 02 206 e mail msembroni arri it ARRI Canada Limited 415 Horner Avenue Unit 11 Toronto Ontario MaW AW3 Canada phone 1 416 255 3335 fax 1416 255 3399 e mail service arrican com technical data is subject to change without notice ARRI 2011 UDM User Manual ARRI Order no K5 65999 0 ARNOLD amp RICHTER CINE TECHNIK T rkenstr 89 D 80799 M nchen Phone 49 0 89 3809 0 Fax 49 0 89 3809 1244 www arri com
7. commended by ARRI as they may cause The UDM has been thoroughly tested for quality of hazards and void the warranty workmanship and operating functions before leaving the factory To ensure optimal performance it is essential that you aquaint yourself with this instruction manual and that you follow the operating instructions described Do not repair any part of the system Repairs must only be carried out by authorized ARRI repair shops Do not remove any safety measure of the system Warning signs Do not operate the system in high humidity R areas or expose it to water or moisture Possible risk of injury or damage to equipment Operate the system using only the type of This symbol indicates the risk of electric shock power source indicated in the manual or fire danger that could result in injury or equipment damage Do not use solvents to clean General safety instructions Any violation of these safety instructions or the non observance of personal care could cause serious injuries including death and Read and understand all safety and damages on the system or other objects operating instructions before you operate or install the system Product Identification Retain all safety and operating instructions When ordering parts or accessories or if any questions should for future reference arise please advise your type of produc and serial number 2 2 Disclaimer Before using the products described in this manual
8. cription The ARRI Ultrasonic Distance Measure UDM provides a continuous reflection based distance measurement and automatic focus tracking using the built in Lens Data System of the ALEXA Plus ARRICAM ARRIFLEX 435 Advanced Xtreme and ARRIFLEX 416plus cameras or the UMC 3 lens motor controller Main features Measurement range from approx 0 4 10m 1ft 4in 33ft Selectable Meter Feet display Automatic focus tracking with ARRI Lens Data System equipment Pre set measuring limits for exact object tracking Fine trimming for best performance in different environments Large transflective LCD display for good readability under all light conditions The UDM consist of two units the Display Unit and the Sensor Unit 3 8 UNC bushings allow the units to be mounted on standard supports in convenient positions The UDM comes with an 1 5m 5ft interface cable Connection cables for interfacing to cameras and UMC 3 must be ordered seperately page 9 A large control wheel on the Display Unit allows easy setting of the UDM parameters supported by a set of status LEDs The small toggle switch under the large LCD display changes the unit of measurement between meters and feet Display Unit K2 65131 0 optional power supply data cable please refer to page 9 Sensor Unit K2 65130 0 UDM Sensor Cable blue label K4 65655 0 3 1 Order Numbers K0 60055 0 Ultrasonic Distance Measure UD
9. tellectual property rights of third parties by or arising from the use of ARRI products or any other liability arising from the use of such products No license express implied or otherwise is granted under any patents copyrights or other intellectual property rights of ARRI or others ARRI or its subsidiaries expressly excludes any liability warranty demand or other obligation for any claim representation or cause or action or whatsoever express or implied whether in contract or tort including negligence or incorporated in terms and conditions whether by statue law or otherwise In no event shall ARRI or its subsidiaries be liable for or you have a remedy for recovery of any special direct indirect incidental or consequential damages including but not limited to lost profits lost savings lost revenues or economic loss of any kind or for any claim by third party downtime good will damage to or replacement of equipment or property any costs or recovering of any material or goods associated with the assembly or use of our products or any other damages or injury of persons and so on or under any other legal theory In the case one or all of the forgoing clauses are not allowed by applicable law the fullest extent permissible clauses by applica ble law are validated ARRI registered trademark of Amold amp Richter Cine Technik GmbH amp Co Betriebs KG This page is left intentionally blank 3 General Des
10. ulated Depth of Field range blinking indicates the object to being outside of the Depth of Field range No light indicates that no camera Depth of Field signal is available 5 3 Operation Settings During operation the following changes or adjustments are available Selection of the unit of distance measurement Use the toggle switch to select either m cm or ft in Setting of sensitivity Press the control wheel briefly the SENSITIVITY LED starts blinking indicating the device is in sensitivity mode Turn the control wheel and set the new sensitivity value The value range starts at O OFF and ends at 100 MAX Adjust so that you achieve a steady green SENSE light in the desired measurement range Press the control wheel briefly again to return to normal operation Setting of Film Plane offset When the Sensor Unit is not mounted on the film plane the Film Plane offset will need to be recalibrated Measure the distance between the film plane and the object Press and hold the Control Wheel for about 1 5sec until the FILM PLANE LED starts blinking Turn the Control Wheel until the correct distance is displayed Press the Control Wheel briefly again to return to normal operation 5 4 Parameter Settings Enter the parameter setting mode by pressing and holding the Control Wheel during power on Scroll through the parameter settings by repeatedly pressing the control knob briefly The following settings are available Displa
11. us UMC 3 LDD FP with Lens Table stored in Lens Data Archive ALEXA and ALEXA Plus Cable Control LCS bus cable LC Z1 LC Z2 LC M1 LC M2 WHA 3 WFU 1 3 CLM 2 Metering LDD FP with Cable LDD RDO K2 54172 0 Wireless Control WMU 3 WFU 3 WEB 3 WBU 3 4 LDD FP Always use the latest Camera and UMC 3 software packets for secure operation 5 Operation of the UDM 5 1 Switching on The UDM has no dedicated power switch Power on the UDM by using the power switch of the connected supply source Camera UMC 3 or connect the appropriate UDM cable to the supply unit C C ss _ 7umir AO O Lps boF f S n SENSE O PLANE SENSITIVITY SENSOR j 3i SUR er 5 2 Controls and Status LEDs The blue Control Wheel is used for configuration setup Push to select and turn to change values The Toggle Switch changes the unit of measurement between Metres and centimetres and Feet and inches SENSE LED steady green shows successful measurement FILM PLANE LED yellow blinking indicates film plane offset adjustment mode SENSTIVITY LED yellow blinking indicates sensitivity adjustment mode LIMIT LEDs yellow blinking indicates value setting mode steady light indicates limits set to other than maximum default value LDS DOF LED steady light indicates the object as being within the calc
12. y backlight brightness Default value L 100 settings from to 200 LOWER LIMIT display range Lower LIMIT LED blinking Default value 0 00 m OftOin settings from to 15 00 m 49 2in UPPER LIMIT display range Upper LIMIT LED blinking Default value 15 00 m 49f 2in settings from 15 00 m 49ft 2in to O Display Resolution step width of least significant digit Default value r O settings from O to 5 Default Reset Default value dno stores user set parameters dEF resets to default values Press and hold the Control Wheel to retum to normal operation 5 5 Depth of Field and Focus Tracking Using the settings and accessories described in chapter 4 2 the UDM uses the LDD FP or the WRC 2 with LDD FP software option as a display for the actual Depth of Field As the LDD FP provides the complete UDM information the UDM Display Unit may be disconnected after parameters have been set Indicators on the LDD FP show the following An active UDM or CTM the measured distance and actual Depth of Field Depth of Field is shown graphically as a bar graph and is also displayed as numeric value In a cabled configuration the Focus Tracking function can be activated by pressing and holding the blue tracking button on the left side of the WHA 3 Using the wireless setup press and hold the BRIGHT UP button on the LDD FP As long the button is kept pressed the focus motor will follow the measured distance Fos 24 000 798

Download Pdf Manuals

image

Related Search

Related Contents

Board User`s Manual "CPU Board XMC4400 General  iStarUSA IS-700S2UPD8 power supply unit  FOR POOL AND SPA MAGICSTREAM® LAMINAR  Verser votre Taxe d`Apprentissage  AreaList Pro manual - e-Node  Téléchargez Garrigues n°53 - Conservatoire d`espaces naturels de  Sencor SRC 180 RD  Gebrauchsanleitung für den Bohrmaschinenvorsatz  カタログ - チノー  