Home

User Manual of ATC-1000

image

Contents

1. your Copyrights Nordfield Electronics remote application is using 5 6 UDP Client Remote Connection Port Number default 21 range 0 to 65535 Remote Host IP Address default 192 168 2 2 If your device is acting as an active device to report real time status to a remote device and the data be guaranteed to be received by the peer is not your concern then you can set XS1000 as TCP Client Be sure the value of item Remote Connection Port Number is same as your remote control application using the correct value of Remote Host IP Address Telnet Control Ttem Value Telnet Server Client Server Client Port Number 23 Remote Server IP Address Bo Po fist fica Update 6 0 UART Control RS 232 Use VCOM for creating a new COM port The XS1000 support three serial types RS232 RS422 and RS485 Baud Rate default 57600 range 300bps to 230 4Kbps Character Bits 5 6 7 8 default Parity Check None default even odd space mark Stop Bits 1 default 1 5 or 2 Hardware Flow Control None default or Hardware Mechanical dimensions 32mm 25m 94mm XS 1000 10mm 45mm 19 5mm OO Oe aa I l I I 4 Pi 65mm 25mm Copyrights Nordfield Electronics Note to Admin Panel s UART Control advanced settings Character 1 and 2 These are HEX numbers Default value OOFF When sending data from serial to TCP the data is fist stored in the cache not until the val
2. NordField Electronics XS1000 TCP IP to RS232 422 485 Device Server Overview and quick info sheet 1 0 Introduction The XS1000 is a cost effective and highly integrated Serial to Ethernet 10 100Mbps device server Embedding a 8051CPU with 64KB OTP ROM and 32KB SRAM The serial interface supports handshake signals RTS and CTS The XS1000 can access 1 x RS232 422 485 devices located virtually anywhere via Ethernet or Internet The XS1000 automatically finds devices in the network and can be configured by the serial Port Telnet or WEB Browser 2 0 Features 3 in 1 RS 232 422 485 interface Max 230Kbps Serial interface and 10 100 Mbps Ethernet Supports 4 and 2 wire RS 485 with AUTO SENDTM and built in terminator Power supply 24 VDC and optional Power over Serial Terminal block for easy RS 422 485 serial wiring Supports IP configuration by MAC address Supports Driver TCP Server Client UDP Server Client and Pair Connection protocols Easy and powerful configuration management Approvals CE RoHS 3 0 Hardware Installation amp Initial Setup 3 1 RS 232 Configuration DB9 Male PIN2 RXD PINS TXD PINS GND PIN7 RTS PIN8 amp 3 2 RS 422 485 Configuration terminal header Terminal 1 2 3 4 5 No Ps4 m 1 re vin ono Cases aos 485 vin ono 3 3 Connecting to 10 100M Use a standard Ethernet cable to connect the XS1000 to an Ethernet switch or use a cross ove
3. age can be downloaded at mail nordfield com with any issues http www nordfield com downloads xs1000 xs1000 zip Copyrights NordField Copyrights Nordfield Electronics
4. device to accept commands from a remote device and the data needs to be guaranteed to be received by the peer is your concern then you can set the XS1000 as TCP Server Be sure the value of the setting Port Number is same as your remote control application using Client mode inactive timeout minutes default 20 0 Disable If you want to keep the connection between XS1000 and your remote control application always on then set the value of item Client mode inactive timeout minutes to 0 otherwise when the inactive time of no traffic on the line reach the configured value the XS1000 will terminate the connection 5 4 TCP Client Remote Connection Port Number default 23 range 0 to 65535 Remote Host IP Address default 210 200 181 102 If your device is acting as an active device to report real time status to remote devices and the data needs to be guaranteed to be received by the peer is your concern then you can set the XS1000 as TCP Client Be sure the value of the setting Remote Connection Port Number is same as your remote control application using the correct value of Remote Host IP Address 5 5 UDP Server Local Port Number default 21 range 0 to 65535 If your device is acting as a passive device to accept commands from a remote device and the data needs to be guaranteed to be received by peer is not your concern then you can set XS1000 as UDP Server Be sure the value of item Local Port Number is same as what
5. ication system IP System Status Load default setting Functions TCP Mode UDP Mode ADC DIDO Reset Device Menus explained 4 3 Administrator Setup Main admin window 4 4 Authentication The user can change the username and password to prevent unauthorized access Login ID and password authentication the maximum number of characters is 15 characters and numbers User Name default admin Password default system Authentication Configuration Setting Value fadmain max 15 Password Fe max 15 Confirm s Update Username 4 5 System IP The XS1000 support two IP connection types Static IP and Copyrights Nordfield Electronics DHCP These types are listed in the Web page for the IP Configuration settings Each setup screen and available features will differ depending on what kind of IP connection types you select Default is Static IP System IP Configuration T Setting Value IP Address NS fies RE ft i Subnet Mask 255 255 55 p 4 Gateway HS fies D asa DNS FREE Static DHCP IP Configure Static or Fixed IP IP Address default 192 168 2 1 Subnet mask default 255 255 255 0 Gateway default 192 168 2 254 Primary DNS default 192 168 2 253 If you are connecting through a static or fixed IP from your network environment perform these steps Step 1 Enter IP address Step 2 Enter Subnet mask Step 3 Ente
6. r Gateway IP address Step 4 Enter Primary DNS IP address Step 5 click Update button 4 6 DHCP Host Name Optional default NETUART maximum length 15 characters If there is a DHCP Server existing in your network environment you can set the IP configuration to DHCP to get a dynamic IP address The Host Name is an optional item depending on your DHCP Server setting 5 0 System Status This screen shows the XS1000 s current status All of the information provided is read only Kernel Version the installed version of the kernel MAC Address The present device MAC Address Nickname the product s NetUART model name system Status MAC Address 00 00 11 33 FF 00 Nickname NetUART Update System Version V3 0 060110 5 0 Load default setting Allows the user to reset the XS1000 to default settings The MAC Address will not be updated Load Default Setting to EEPROM foal 5 1 Telnet Telnet connection setting Telnet Server Client Currently used to determine if the device is a Telnet Server or Client 5 2 Operation mode The XS1000 supports four operation modes TCP Server TCP Client UDP Server and UDP Client These modes are listed in the Web page for the Operation Mode setting Each setup screen and available features will differ depending on what kind of operation mode you select Default is TCP Server 5 3 TCP Server Port Number default 23 range 0 to 65535 If your device is acting as a passive
7. r cable if you connect it directly to a PC 3 4 Power Supply XS1000 needs a 9 to 24VDC 1000mA power supply 3 5 XS1000 LED indication LINK Ethernet Link established ACT Data flow TX RX PWR Power ON 3 6 Connection Diagram RS 232 Connection Copyrights Nordfield Electronics PC TS Razz Alt X P 21 Ih ADN ai LL y he La N EJ J a y RS NE DBO Fema DBO Female x51000 ReD 7 3 Txt TD 3 2 RxD GND 5 5 GND RS 422 Connection T 1 T 2 R 3 R 4 ATC 1000 RS 485 Connection 485 1 ATC 1000 4 0 Installation Configuration and Operation A Assign a static IP address to your computer in the 192 168 2 2 to 192 168 2 254 range Subnet mask 255 255 255 0 This is necessary to ensure that your computer can communicate with your XS1000 Your computer must have an Ethernet card and TCP IP installed TCP IP should already be installed on computer using Windows 98 2000 XP and later operating systems B The default IP address of the XS1000 is 192 168 2 1 Open your web browser and enter this IP address to connect to the XS1000 C Default user name is admin and the password is system Click OK The setup screen will then appear and you can now configure the settings D Create a new COM port using VCOM exe olte 192 168 2 1 IL drain Fassword persan 4 2 The menu features as below Administrator Authent
8. ue of character 1 or 2 is received from the serial side the data is released from the cache and sent to TCP Silent time If there is no data sent or received for the number of milliseconds specified the connection is dropped Drop character Drops the delimiter character of the serial port when sending to TCP the receiver doesn t display the character How to hardware reset XS1000 Disconnect the Ethernet cable Disconnect the serial cable Disconnect the power supply Unscrew the two screws on each side on the unit and carefully remove the cover Locate the small white reset button next to the power supply jack Press and hold the reset button While holding the reset button connect the power supply To access technical support please visit the U S Converters website at CO N O ao A W N The Power LED light will come on 9 After 7 10 seconds while holding the reset button the green LED will flash briefly one time www Nordfield com 10 The ATC 1000 now has been reset to factory settings Here you will find Notice the unit can also be reset from the web interface Latest drivers and updates for download Technical tips Documentation Configuration support and much more For installation please refer to our step by step installation guide http www nordfield com downloads xs1000 vcom setup guide xs 1000 Feel free to contact our technical support team at Full driver and documentation pack

Download Pdf Manuals

image

Related Search

Related Contents

Copyright © All rights reserved.
Failed to retrieve file