Home

MBB200C User`s Manual

image

Contents

1. ANA U CH O oo c g g 33a 28 5 gull Q am GO i os E Oo gt GL p o I x g a N X 0 Figure 3 MBB200C Front Panel Connections Revision 1 0 Page 5 MBB200C User s Manual The I O interface panel located on the rear of the MBB200C see Figure 4 has the following interface connectors e 1x VGA output 1 x RS 232 Serial Port 2 x USB port connectors 1 x Gigabit Ethernet LAN port 1 x 12V DC power jack 1 x 3 pin power terminal block with wide range power input 9V 36V 1 x power switch 2 x USB 2 0 3 pin Power terminal block x lt GE gt S od a O o A Figure 4 MBB200C Front Panel 2 4 1 RS 232 Connection There is one external RS 232 connector The RS 232 connector enables connection to an external touch screen To connect a serial cable with the RS 232 connector please follow the instructions below Step 1 Locate the RS 232 connector on the rear panel of the MBB200C Page 6 Revision 1 0 Maretron Step 2 Align the RS 232 connector on the serial cable with the RS 232 connector on the rear panel of the MBB200C Step 3 Once aligned gently insert the serial cable RS 232 connector into the MBB200C RS 232 connector 2 4 2 VGA Connection There is one external VGA connector The VGA connector enables connection to a monitor To connect a VGA cable with the VGA connector please follow the instructions below Step 1 Locate the VGA connector on the rear panel of the MBB200C
2. 2 3 Mounting the MBB200C The MBB200C can be mounted to a wall or other flat surface with the included mounting brackets 2 3 1 Mounting the System with Mounting Brackets To mount the MBB200C onto a wall or some other surface using the two mounting brackets please follow the steps below Step 1 Turn the MBB200C over Step 2 Align the two retention screw holes in each bracket with the corresponding retention screw holes on the sides of the MBB200C bottom surface marked in red in Figure 2 Step 3 Secure the brackets to the MBB200C by inserting two retention screws into each bracket Step 4 Drill holes in the intended installation surface Step 5 Align the mounting holes in the sides of the mounting brackets with the predrilled holes in the mounting surface Step 6 Insert four retention screws two in each bracket to secure the MBB200C to the wall Page 4 Revision 1 0 Maretron e Br 3 Figure 2 Mounting Bracket Screw Hole Locations 2 4 Connecting the MBB200C Most I O interface connections of the MBB200C are found on the front panel see Figure 3 The I O interface panel located on the front of the MBB200C has the following I O interface connectors e 2x CAN bus ports with isolation for connection to NMEA 2000 1 x CompactFlash Card Socket 1 x HDD LED indicator 1 x Audio line out jack green 1 x Mic in port pink 1 x Power LED Indicator 1 x Reset button 2 x USB 2 0 connectors
3. The Maretron MBB200C is designed to operate within the harsh demands of the marine environment However no piece of marine electronic equipment can function properly unless installed configured and maintained in the correct manner Please read carefully and follow these instructions for installation configuration and usage of the Maretron MBB200C in order to ensure optimal performance 1 2 Firmware Revision This manual corresponds to the MBB200C running N2KView Version 4 0 2 1 3 MBB200C Features NOTE Although the MBB200C looks similar to the former MBB100 product there are important differences The MBB200C is a standalone NMEA 2000 computer with the following features e The MBB200C includes two CAN interfaces for direct connection to one or two NMEA 2000 networks The MBB200C includes all N2KView capabilities that were formerly licensed separately in the MBB200 Alerts Control Fuel Management and Video No gateways such as the IPG100 hardware license keys or additional software licenses are needed You don t need to connect or configure LAN connections unless you are using Video or E mail alert actions N2KView configurations are transferred to and from other N2KView devices using a USB flash drive plugged into one of the MBB200C s USB ports Page 2 Revision 1 0 Maretron The Maretron MBB200C has the following features e Full version of N2KView software preinstalled Wired Ethernet interface Dua
4. eure n2kview IP Address 10 0019 Subnet Mask Default DNS Close Figure 11 Configuration Dialog Uncheck the DHCP box to indicate that your LAN does not use DHCP In the IP Address field enter the IP address you wish to assign to the MBB200C Click on the Configuration button in the Commands amp Settings window to display the Configuration dialog Revision 1 0 Page 11 MBB200C User s Manual h In the Subnet Mask field enter the subnet mask value used on your LAN in most cases this value will be 255 255 255 0 i In the Default Gateway field enter the IP address of the default gateway of your LAN j In the Default DNS field enter the IP address of a DNS Dynamic Name Service Server used on your LAN k Click the Update button to make these changes permanent The screen will go blank for a few seconds while this is being done Page 12 Revision 1 0 Maretron 3 Operating the MBB200C 3 1 Turning the MBB200C On To turn on the MBB200C press the power switch located on the right hand side of the front panel of the MBB200C 3 2 Turning the MBB200C Off To turn the MBB200C off use the Shutdown administrative tab of the N2KView software Alternatively you can power down the unit by pressing the MBB200C s power switch Lastly you can power down the unit by turning off the power source with an external breaker or external switch 3 3 Using
5. Dynamic Host Control Protocol server If your local area network uses a DHCP server no configuration is necessary and the MBB200C should be able to successfully connect to the local area network If your local area network does not use DHCP you must manually enter the LAN connection information into the MBB200C This is done through the following steps Engines Engine Room DC Systems un 3000 Nav Lights Fire Alarms Motion amp Door S 40005 eee 4 m RPM Alternator Voltage Load World Clocks AN EN N SEN od w ov H ee ES J o O Figure 9 N2KView Window with Tabs Displayed a Click anywhere inside the N2KView screen to display the screen tabs as shown in Figure 9 above b Click on the Commands amp Settings tab on the right to display the Commands amp Settings Dialog Page 10 Revision 1 0 f g Maretron Commands amp Settings x Alerts Setup Breaker Lockout Cameras Setup Configuration Connections Enter Full Screen Load Shedding Night Mode Password Clean Screen Screens Setup CE EN ES Figure 10 Commands and Settings Dialog Click on the Configuration button in the Commands amp Settings window to display the Configuration dialog Click on the Network Configuration tab in the Configuration dialog to display the Network Configuration dialog Configuration Default Gateway Network Configuration Screen Configuration DHCP
6. LLP Attn Technical Support 9014 N 23 Ave Suite 10 Phoenix AZ 85021 USA Revision 1 0 Page 17 MBB200C User s Manual 8 Maretron 2 Year Limited Warranty Maretron warrants the MBB200C to be free from defects in materials and workmanship for two 2 years from the date of original purchase If within the applicable period any such products shall be proved to Maretron s satisfaction to fail to meet the above limited warranty such products shall be repaired or replaced at Maretron s option Purchaser s exclusive remedy and Maretron s sole obligation hereunder provided product is returned pursuant to the return requirements below shall be limited to the repair or replacement at Maretron s option of any product not meeting the above limited warranty and which is returned to Maretron or if Maretron is unable to deliver a replacement that is free from defects in materials or workmanship Purchaser s payment for such product will be refunded Maretron assumes no liability whatsoever for expenses of removing any defective product or part or for installing the repaired product or part or a replacement therefore or for any loss or damage to equipment in connection with which Maretron s products or parts shall be used With respect to products not manufactured by Maretron Maretron s warranty obligation shall in all respects conform to and be limited to the warranty actually extended to Maretron by its supplier The foregoing warranties
7. Maretron MBB200C Vessel Monitoring and Control Black Box User s Manual Revision 1 0 Copyright 2014 Maretron LLP All Rights Reserved Maretron LLP 9014 N 23 Ave 10 Phoenix AZ 85021 7850 http www maretron com Maretron Manual Part M003055 Revision 1 0 Page i MBB200C User s Manual Revision History Rev Description 1 0 Original document Page ii Revision 1 0 Maretron Table of Contents TV GENRE 1 WM TANI IO 0 EE seal sci EEES 1 12 Firmware HG VISION yo cecrssces ct isnot ridi e minini enii neia ean chess eetybsesnahhnA AD dea E GANG a Sites Gen 2 13 WB QOD FG arrene 2 14 NAL 4v4vvuv4444v4rv4v4rer eee 3 MV ERE dleiaesdotubuantaebaasteltiges 4 2 1 Unpacking the BOX SR 4 2 2 Choosing a Mounting Location icc cc careenetencetitcmematetevesddebacendectedeediesaendecdedentivkadncecbeaemadetes 4 22 Mo nting the MBB200G nsise sse Scene eaa oeae aeae Sans teictaemause 4 2 3 1 Mounting the System with Mounting Brackets ccccceeeeeeeeeeeeeeeeeeeeeeeeeeeeeneeeeeeeees 4 2 4 Connecting the MIBBZO0G Luvupsemsmmtesjmdmmoinseasemqmeisagutmspeinspunemispnsidee 5 221 15232 Come Me e a ees abet A ea eee eta E ener tesa 6 242 VGA COMO CWO essiri aeee ae NE e 7 243 LAN CONNEC OM isisisi ieden nannini ecbese ear dnsdd dedn dt add dnedndn 7 2 4 4 USB Device Connection ernnnnnnnnnnnnnnvnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnennnnnnnnnnnnnnnnnennee 8 2 4 5 Power C
8. OEN ee pasde anden capscigddevssuebceeaptedduxedteddecectehdaxactebjacacue dexeoties 8 226 Power Ser 9 2 5 Configuring the WIBR2Q OG hJeessrtridkedeeirepebekebnmebebepene erabeiebdetenecetebenehdneueneueianenenene 9 2 5 1 Manually Entering LAN Connection Information rrrennnnnnnnnnnvrrrnnnnnnnnnrnnnnnrrrnnnnnnnnnnnn 10 3 Operating the ON Otte Bed terete niece cence en 13 3 1 Turning the MBB200C On ac jsocsies ceeccaenenpactcustesdeeacenndececuecoeencunddbenstecdusedee sotcadteadesaciesosmases 13 3 2 Turning the MBB2000 Off event csctccsceneocwbieeienentnnnocdhnenntnestedcondbdcohieendeaededhoednoeeniesienoedneoebabes 13 3 3 USING The MBB ZOOC Lu cctcciccesdccctaandvertneniuaice ottenndnendnends ebdnezdemntethenendneatnandeukinantuandeontenninese 13 4 WAMU INGUIN Cis cient etic eee ede ccs essere eed eine hee ieee deeded tiac bee oiedcsinele de deicck NE 14 5 MOUBIESNOOUNO osese rE etree rer er ene eee rer eee ee eee re 15 6 lechnical Specifications sssrini ASAA EAE aS AEAN 16 7 technical SUD NOM eanit a aa a ai aa a aa a aA 17 8 Maretron 2 Year Limited Warany uLasgadssudssatgsedeemuibetebeksifentjemifdkendeikuen 18 Revision 1 0 Page iii MBB200C User s Manual Table of Figures Figure 1 MBB200C Network Diagram rnrrrnnnnnnnnnnornnnnnrrrnnnnnnnnnnrnnnnnnrrrnnnnenennernnnnnrrnnnnnennssernnnnnnrnnnnen 1 Figure 2 Mounting Bracket Screw Hole Locations cccceeeeeeeeeeeeeeneeeeeeeeeeeeeeeeeeeeeeeeeeeeeesese
9. Step 2 Align the VGA connector on the cable with the VGA connector on the rear panel of the MBB200C Step 3 Once aligned gently insert the cable VGA connector into the MBB200C VGA connector 2 4 3 LAN Connection There is one external RJ 45 LAN connector The RJ 45 connector enables connection to an external network To connect a LAN cable with the RJ 45 connector please follow the instructions below Step 1 Locate the RJ 45 connector on the rear panel of the MBB200C Step 2 Align the RJ 45 connector on the LAN cable with the RJ 45 connector on the rear panel of the MBB200C see Figure 5 Figure 5 LAN Connection Step 3 Once aligned gently insert the LAN cable RJ 45 connector into the onboard RJ 45 connector Revision 1 0 Page 7 MBB200C User s Manual 2 4 4 USB Device Connection There are four external USB 2 0 connectors To connect a USB 2 0 or USB 1 1 device please follow the instructions below Step 1 The locations of the USB connectors are shown in Figure 3 and Figure 4 Step 2 Align the USB device connector with one of the connectors see Figure 6 Figure 6 USB Device Connection Step 3 Once aligned gently insert the USB device connector into the MBB200C connector 2 4 5 Power Connection The MBB200C can be connected to a power source in one of two ways overcurrent protection should be provided and should be sized in accordance with ABYC E 11 AC and DC ELECTRICAL SYSTEMS ON BOATS 1 Direc
10. above To obtain a copy of the then current warranty policy please go to the following web page http www maretron com company warranty php Revision 1 0 Page 19
11. dapter cable included CAN Ports Certifications Parameter Comment FCC class A and CE Mark Electromagnetic Compatibility NMEA 2000 Electrical Parameter Value Comment Operating Voltage Dedicated Supply Connection 9 36 Volts DC Voltage Power Consumption Dedicated Supply 22 2 Watts Connection Operating Voltage NMEA 2000 Connection 8 32 Volts DC Voltage Power Consumption NMEA 2000 Connection OmA Load Equivalence Number LEN 0 NMEA 20000 Spec 1 LEN 50 mA Reverse Battery Protection NMEA 2000 Yes Indefinitely Connection Load Dump Protection NMEA 2000 Connection Yes Energy Rated per SAE J1110 Mechanical Parameter Value Comment Overall Dimensions DxWxH 6 02 x 9 76 x 1 73 Including Flanges for Mounting 153mm x 248mm x 44mm Weight 4 6 lbs 2 1kg Chassis Material Aluminum Mounting VESA 100 Wall Bracket DIN Rail Any Orientation Environmental Parameter Value Operating Temperature 10 C to 60 C Operating Shock Half sine wave shock 3G 11 ms 3 shocks per axis Operating Vibration MIL STD 810F 514 5C 2 Page 16 Revision 1 0 Maretron 7 Technical Support If you require technical support for Maretron products you can reach us in any of the following ways Telephone 1 866 550 9100 Fax 1 602 861 1777 E mail support maretron com World Wide Web _http www maretron com Mail Maretron
12. eaaees 5 Figure 3 MBB200C Front Panel Connections arrrnnnnnnrrnnnnnnnnnnrnnnnnrrrrnnnnnnnnnrrnnnnnrrrnenenennnernnnnnrrnnnnene 5 Figure 4 MBB200C Front Panel ents Stee cnt ca ieee are 6 Figure 5 LAN COMMENT 7 Figure 6 USB Device Connection ass 8 Figure 7 MBB200C Power Terminal Block nrrnnnnnnnnnnnvnnnnnnnonnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnennee 8 Figure 8 MBB200C Startup Screen mrrnnnnnnnnnnnnnnonnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnennee 9 Figure 9 N2KView Window with Tabs Displayed rnsrvrvrvrrrvrererereveverrrrerererevevevererrerererereverererrenenen 10 Figure 10 Commands and Settings Dialog rrrrrnnnnnnrvvonnnnnnonnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnennnnnnnnnnnnnee 11 Figure 11 Configuration Di l gua sanse AS 11 Page iv Revision 1 0 Maretron 1 General 1 1 Introduction Congratulations on your purchase of the Maretron MBB200C Vessel Monitoring and Control Black Box Maretron has designed and built your system to the highest standards for years of dependable and accurate service Maretron s Black Box MBB200C is a dedicated processing unit that includes Maretron s N2KView vessel monitoring and control software Unlike a PC that allows any software to be loaded the MBB200C runs only N2KView software making it extremely stable and dedicated to monitoring and controlling your vessel The MBB200C is ruggedized f
13. ht hand side Check that the NMEA 2000 interfaces are correctly connected to the NMEA 2000 network Other Issues Please refer to the Troubleshooting section of the N2KView User s Manual If these steps do not solve your problem please contact Maretron Technical Support refer to Section Technical Support for contact information Warning There are no user serviceable components inside the Maretron MBB200C Opening the MBB200C will expose the sensitive electronic components to adverse environmental conditions that may render the unit inoperative Please do not open the MBB200C as this will automatically void the warranty If service is required please return the unit to an authorized Maretron service location Revision 1 0 Page 15 MBB200C User s Manual 6 Technical Specifications Specifications Parameter Value Comment Video Connector One VGA Port RGB or D sub 15 For Monitor Connection Monitor Resolution 2048 x 1536 Maximum USB Connector Four USB 2 0 connections For connecting Peripherals Mouse keyboard etc and or touch screen connectivity Serial Connector One RS232 9 Pin D Connector For touch screen alternative connection Touchscreen Drivers TSHARC 3M MicroTouch ELO eGalax Ethernet Connector One RJ 45 GbE For connection to IP Cameras or use for Alert E mail transmission Audio Connection One Speaker Output Controller Area Network Two DB 9 Connectors One NMEA2000 a
14. l Optically Isolated CAN bus connectors for direct NMEA 2000 connection Supports user supplied VGA monitor Supports user supplied touchscreen ELO 3M Microtouch Hampshire TSharc Penmount Supports user supplied mouse and keyboard Supports Bluetooth mice and keyboards with built in Bluetooth adapter Operates on 9 36VDC 25W power consumption Solid State Disk Drive Fanless cooling system All N2KView licenses included 1 4 Quick Install Installing the Maretron MBB200C display involves the following four steps Please refer to the individual sections for additional details e Unpacking the Box Section 2 1 Choosing a Mounting Location Section 2 2 Mounting the MBB200C Section 2 3 Connecting the MBB200C Section 2 4 Configuring the MBB200C Section 2 5 Revision 1 0 Page 3 MBB200C User s Manual 2 Installation 2 1 Unpacking the Box When unpacking the box containing the Maretron MBB200C you should find the following items 1 MBB200C Maretron Vessel Monitoring and Control Black Box 1 NMEA 2000 adapter cable 2 Mounting Brackets 1 Short Screw Set Used for Mounting Bracket 1 AC Power Cord 1 AC Power Supply 1 Rubber Feet Long Screw Set 1 MBB200C User s Manual 1 N2KView Documentation CD ROM 1 Warranty Registration Card If any of these items are missing or damaged please contact Maretron 2 2 Choosing a Mounting Location The MBB200C must be mounted in an indoor location
15. liable they should be used only as aids to navigation and vessel monitoring and control and not as a replacement for traditional aids and techniques Please give this device running N2KView a name e g Helm or Engine Room Exit Enter Demo Mode Accept Figure 8 MBB200C Startup Screen The first time you start the MBB200C N2KView will ask you to assign it a unique name Assigning a unique name to the MBB200C is necessary in order to help you determine the source of alerts generated by a MBB200C or other Maretron device capable of generating alerts You are required to press Accept and thereby acknowledge this warning message before N2KView will run in Live Mode Alternatively you may Enter Demo Mode In Demo Mode you will not be able to connect to an NMEA 2000 network and view live data instead simulated data will be provided to stimulate the controls Finally you may choose Exit in which case the MBB200C will power off Revision 1 0 Page 9 MBB200C User s Manual 2 5 1 Manually Entering LAN Connection Information NOTE The LAN Connection is not necessary unless you are using any of the following features e Video e E mail actions on Alerts If you intend to use the Video feature or send e mails via the Alerts feature you must ensure that the device can connect to your LAN local area network The MBB200C comes from the factory preconfigured to obtain its LAN connection information from a DHCP
16. or marine use and includes a solid state disk drive to withstand the pounding associated with waves And since the MBB200C dissipates less than 25 watts there is no need for internal cooling fans that are noisy and wear out causing electronics to overheat and fail VGA Monitor With Optional Touch Screen VGA USB or RS 232 for Touchscreen Optional USB 7Z Keyboard or 4 Mouse Lu IF VZ NMEA 2000 a Network Monitor Battery I Monitor gt Electrical SV Panel Tank Monitor Figure 1 MBB200C Network Diagram Revision 1 0 Page 1 MBB200C User s Manual The MBB200C connects to a monitor through a VGA connector and associated touch screen through a USB or serial port connection Alternatives to controlling the N2KView software through a touch screen include keyboards mice or track balls connected through USB In addition to the two completely isolated CAN bus connectors M12 for easy connection to single or redundant NMEA 2000 networks the MBB200C has an Ethernet port for connecting Internet Protocol IP cameras for viewing within the N2KView software Of course you get the same flexibility using Maretron s N2KView software from the MBB200C as you would running the software on a PC which includes the ability to configure as many screens as you want with exactly the information you want to see Plus you get free upgrades to the software as improvements and new features are added
17. ration of the software programs or products will be uninterrupted or error free Purchaser assumes responsibility for the selection of the software programs or products to achieve the intended results and for the installation use and results obtained from said programs or products No specifications samples descriptions or illustrations provided Maretron to Purchaser whether directly in trade literature brochures or other documentation shall be construed as warranties of any kind and any failure to conform with such specifications samples descriptions or illustrations shall not constitute any breach of Maretron s limited warranty Page 18 Revision 1 0 Maretron Warranty Return Procedure To apply for warranty claims contact Maretron or one of its dealers to describe the problem and determine the appropriate course of action If a return is necessary place the product in its original packaging together with proof of purchase and send to an Authorized Maretron Service Location You are responsible for all shipping and insurance charges Maretron will return the replaced or repaired product with all shipping and handling prepaid except for requests requiring expedited shipping i e overnight shipments Failure to follow this warranty return procedure could result in the product s warranty becoming null and void Maretron reserves the right to modify or replace at its sole discretion without prior notification the warranty listed
18. shall not apply with respect to products subjected to negligence misuse misapplication accident damages by circumstances beyond Maretron s control to improper installation operation maintenance or storage or to other than normal use or service THE FOREGOING WARRANTIES ARE EXPRESSLY IN LIEU OF AND EXCLUDES ALL OTHER EXPRESS OR IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND OF FITNESS FOR A PARTICULAR PURPOSE Statements made by any person including representatives of Maretron which are inconsistent or in conflict with the terms of this Limited Warranty shall not be binding upon Maretron unless reduced to writing and approved by an officer of Maretron INNO CASE WILL MARETRON BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES DAMAGES FOR LOSS OF USE LOSS OF ANTICIPATED PROFITS OR SAVINGS OR ANY OTHER LOSS INCURRED BECAUSE OF INTERRUPTION OF SERVICE IN NO EVENT SHALL MARETRON S AGGREGATE LIABILITY EXCEED THE PURCHASE PRICE OF THE PRODUCT S INVOLVED MARETRON SHALL NOT BE SUBJECT TO ANY OTHER OBLIGATIONS OR LIABILITIES WHETHER ARISING OUT OF BREACH OF CONTRACT OR WARRANTY TORT INCLUDING NEGLIGENCE OR OTHER THEORIES OF LAW WITH RESPECT TO PRODUCTS SOLD OR SERVICES RENDERED BY MARETRON OR ANY UNDERTAKINGS ACTS OR OMISSIONS RELATING THERETO Maretron does not warrant that the functions contained in any software programs or products will meet purchaser s requirements or that the ope
19. the MBB200C The MBB200C runs a fully functional version of the Maretron N2KView software Please refer to the N2KView User s Manual packaged with the MBB200C for detailed operating instructions Revision 1 0 Page 13 MBB200C User s Manual 4 Maintenance Regular maintenance is important to ensure continued proper operation of the Maretron MBB200C Perform the following tasks periodically e Clean the unit with a soft cloth Do not use chemical cleaners as they may remove paint or markings or may corrode the MBB200C enclosure or seals Do not use any cleaners containing acetone as they will deteriorate the plastic enclosure Do not spray cleaning liquids directly onto the MBB200C e Ensure that the unit is mounted securely and cannot be moved relative to the mounting surface If the unit is loose tighten the mounting screws e Check the security of the power and network cables connected to the MBB200C and tighten if necessary Page 14 Revision 1 0 Maretron 5 Troubleshooting If you notice unexpected operation of the Maretron MBB200C follow the troubleshooting procedures in this section to remedy simple problems No activity on the display Check the connection to the power and network connectors and tighten if necessary Ensure that power is supplied to the connected power cable Check the connection to the power jack located on the rear of the device Press the power switch located on the front of the device on the rig
20. tly with 9 32VDC power source using the green power terminal block found on the rear panel of the MBB200C see Figure 7 a Connect the power source negative terminal to the right hand terminal b Connect the power source positive terminal to the center terminal Cable vec Ground Figure 7 MBB200C Power Terminal Block 2 Indirectly with 100 240VAC 47 63Hz power source using the AC power adapter and the AC power cord supplied in the box a Connect the AC power cord to the AC power adapter b Connect the AC power cord to the AC power outlet c Connect the 12VDC connector from the AC power adapter to the MBB200C s 12VDC power input connector Page 8 Revision 1 0 Maretron 2 4 6 Power Sequencing When the MBB200C is connected to an appropriate power source you can use the power switch located on the front panel see Figure 4 to turn the MBB200C on or off The MBB200C can also be switched on and off by applying or removing power through an external switch or breaker Any time the power is reapplied to the MBB200C it will turn on 2 5 Configuring the MBB200C In order to use the MBB200C you must have it connected to the NMEA 2000 network The MBB200C will start up with the following warning screen T Warning Maretron N2KView Vessel Monitoring and Control System Software Version 4 0 2 20140107 WARNING By pressing Accept you acknowledge that while Maretron products are designed to be accurate and re

Download Pdf Manuals

image

Related Search

Related Contents

Estimation des incertitudes sur les mesurages de B[a]  コントローラ取扱説明書(C-3)  Manual del Usuario TOP POS (Top Point Of Sale)  GAK 600 T - Website for Güde  TC76207 - Velleman  User Manual  TATA Photon Whiz User Manual  Code de la Santé Publique Partie réglementaire Quatri  Tangent Duo Clock Radio - Black  CRO-5500 Redundant RAID Controller Kit  