Integrated Amplifier 530 Integrated Amplifier 530 User manual User
Contents
1. IN 4 IN 5 1 30 50 1 30 50 50 80 lt 9 0 9 gt OFF AUX CD DAC DVD PHON SACD TUNE etc Remarks Start Mode defines the behaviour of the 530 after switch on It can always be switched off via the power button on the front panel Defines which input shall be active after start up Defines the Start Volume level In the value domain it changes to the Start Volume level Defines the Dim Volume level In the value domain it changes to the Dim Volume level The maximal volume can be limited Espe cially for high efficiency loudspeakers this function should be activated In the value domain the volume level does not change Balance defines the level difference be tween left and right channel The inputs IN 1 IN 5 can be renamed individually Function PHONO HP ON 1 SURRDUNGD IN IM 44 HURROUNGD UDL 4g GROUND LIPFT OFF 3 ERIGHTNES REMOTE ID r LOARD DEFHULT Tot Values ON OFF OFF IN 1 In 2 IN3 IN 4 20 50 80 OFF connected ON disconn l low 2 medium 3 high 1 2 Integrated amplifier 530 User manual a a A Remarks Phono High Pass de activates the sub sonic filter RIAA norm OFF should be used only for top quality LP s and decoup led turntables The volume and balance settings of the preamp do not have any influence in the Surround IN Defines the output level for the Surround
2. 4dB 10dB 64dB A Omit feedback loops while connecting recording devices Speaker F Use top quality cables for the connection to your loudspeakers Gain Volume 80 INI amp IN2 INZ amp IN4 IN 5 Phono 36dB 42dB 96dB LINK G The LINK connection allows controlling the switch on of other soulution products Start Mode defines the behaviour of the 520 after switch on RS 232 Interface H All functions can be controlled through the RS 232 interface Seite 7 soulution nature of sound A S A 5 Front side Power J With the Power button you define the operating condition ON or OFF red LEDs In operating condition OFF the audio circuits are completely disconnected from the outputs We suggest switching off the 520 power consumption in lt 0 5W while not listening to music It can easily be activated with the remote control LINK System The integrated amplifier 530 remains in MUTE until all connected LINK components are switched on Display LINK Connect If an error occurs within a LINK component the display shows LINK ERROR When the integrated amplifier 530 is switched off all connected LINK components are switched off simultaneously operating condition OFF Seite 8 Integrated amplifier 530 User manual A a ES Mute K The safety function Mute allows disconnecting all inputs SHLD IH 1 from the outputs in case of an emergency wrong cabling MUTE feedback loops etc Pro
3. soulution 12 Seite nature of sound i ee 16 Specification Specification General Nominal voltage Nominal rating Power consumption Input Impedance Main Out Power rating Current rating Gain Frequency response Slew rate THD N Damping factor Signal to Noise ratio Crosstalk Pre Out Gain Frequency response THD N Signal to Noise ratio Crosstalk Impedance Dimensions Dimensions Weight Standby IN 1 IN 5 Balanced IN 1 IN 2 Unbalanced IN 3 IN 4 Phono IN 5 8Q 4Q 2 Q dynamic Balanced Unbalanced Data 100 240 V 50 60 Hz 1000 2000 W lt 0 5 W 10 kQ 47 KQ Adjustable 125 W 250 W 500 W 45 A max 37 42 dB DC 800 kHz 0 9 us lt 0 001 gt 10 000 gt 120 dB gt 110 dB 63 16 dB 69 10 dB DC 800 kHz lt 0 001 gt 120 dB lt 120 dB 10 Q 442x448x350 mm ca 40 kg Technical specifications are subject to change without prior notification Integrated amplifier 530 User manual a lt 13 Dimensions 350 mm 75 mm 38 mm gt 448 mm Q mute Q me power soulution 442 mm Seite 17 Spemot AG Industriestrasse 70 CH 4657 Dulliken www soulution audio com info soulution audio com soulution nature of sound part no 92149
4. IN The setting is ignored if Surround IN is set to OFF Dis connects the ground of the balanced outputs The intensity of the display can be ad justed in three steps Defines the identification of the 530 The identification of the remote control has to be defined accordingly Activates the default values bold for all functions Seite 13 soulution Seite 14 nature of sound i ee Trouble shooting Error No display No music PROTECT POWER FAIL OVERCURRENT Action Check the cabling to the mains supply Eventually replace the fuse Check cabling to the source components cabling to the loudspeaker if the proper input has been selected if the source component is in MUTE Protect Mode is activated in following cases current to the loudspeakers gt 45 A DC offset audio signal high frequency signal in power amplifier section too high temperature of power transistors In case of a short circuit in the power supply the unit Switches off automatically The display shows POWERFAIL If the current at the pre out is higher than 0 2 A the MUTE function is activated and the display shows OVERCURRENT If you can not identify the error please disconnect the integrated amplifier 530 from the mains supply and contact your soulution dealer Service If your soulution product needs service please contact your soulution dealer For fur ther information see www soulution audio com 10 11 Integrate
5. Integrated Amplifier 530 User manual soulution nature of sound Integrated amplifier 530 User manual a lt Dear client We are proud that you decided yourself for a soulution amplifier You have acquired an integrated amplifier with outstanding sonic performance which you will enjoy for many years We understand your eagerness to get started but even though please study this manual step by step before you integrate the integrated amplifier 530 in your High Fidelity system This manual contains also useful tips for the optimisation of your overall HiFi system If there are any questions regarding the start up or operation of your integrated am plifier please do not hesitate to contact your dealer Have fun Your soulution team Seite 1 soulution Seite 2 nature of sound a u CE Declaration of Conformity Spemot AG declares that this product is in conformance with the following direc tives and standards Low Voltage Directive 2006 95 EG EN IEC 60065 2002 Electromagnetic Compatibility 2004 108 EG EN 55013 2001 EN 55020 2002 EN 61000 3 2 2006 EN61000 3 3 1995 FCC Notice Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are de signed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequen
6. cy energy and if not installed and used in accordance with the instructions may cause harm ful interference to radio communications However there is no guarantee that inter ference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encour aged to try to correct the interference by one or more of the following measures adjust or relocate the receiving antenna increase the separation between the equipment and the receiver connect the equipment into a mains outlet on a circuit different from that to which the receiver is connected consult the dealer or an experienced radio TV technician for help Disposal According to the Directive 2002 96 EG of the European Parliament used consumer electro technical appliances have to be disposed separately and have to be indicated with the following symbol Ea In the case of disposal of this component please do so in conformity with legal and environmental regulations Integrated amplifier User manual Table of contents 1 Technical eli airada A 2 Safety advice Mao cccccccccccccseecccceceenneecceseenteeeeeesetnteeeeeeseennteteeeeeenas 5 3 cope Of OSI encierra 6 A ee ea A 6 5 FI SC na aaa ta E AE tere 8 6 REMOS CONTO arios 10 POSTS MIOS tinta orita 11 8 TrOUblE SHOOENE ernennen 14 9 IN o E E NSR 14 10 Sara UNCI Oratoria notre 15 11 e e
7. d amplifier User manual a lt Safety functions Overcurrent For currents gt 0 2 Ampere at the output the integrated ampli fier 530 shuts down automatically Power supply The power supply is monitored for correct operation In case of an error the 530 gets shut down automatically Audio Signal The audio signal is monitored for DC and high frequency com ponents In case the threshold values are reached the 530 gets switched of automatically Temperature The 530 is switched of automatically if the operating tempera ture of the power transistors gets too high Fuse Model 220 240 V 10A T 250V micro fuse 5x20mm Model 100 120 V 16A T 250V micro fuse bx20mm Warranty All soulution products are guaranteed against defects in material and workmanship for five years from date of purchase The guarantee is void if the product has been subject to misuse or negligence or has been modified repaired or opened by a non authorised person without written au thorisation of Spemot AG For the return transport to our premises please use exclusively the original packag ing Transport damages are not subject to this guarantee repairs will be charged We recommend effecting transport Insurance If you do not posses the original packaging no more please contact your soulution dealer Basic repairs may be completed by your soulution dealer Please clarify whether he is able to do the work before you send the product back to us 530 15
8. e ii O 15 12 o A e OR a ee 16 13 DIMCASION S en een stos coda aires 17 Quick start Unpack your integrated amplifier 530 Unpacking Keep the packing for future transportations Positioning A A Treat the top class surface with care Position the integrated amplifier 530 on a stable base Cooling air must be able to escape unrestricted Disconnect all appliances of your system from the mains Connect the 530 with your loudspeakers Connect the 530 with your source components Cabling Connect all appliances of your system with the mains A The 530 must remain disconnect from the mains gt l Default values for all functions are programmed earn e No additional programming is required for the start up Switch on the integrated amplifier 530 Select a moderate volume level Switch on Switch on your source components A Check the cabling before switch on Seite 530 3 soulution Seite 4 nature of sound eee Technical Highlights Design The audio section of the 530 is physically separated from the power supply and digital circuits In order to reduce interferences to a minimum these sections are additionally shielded The power amplifier section is executed in dual mono layout The left and right audio channels have their own respective identical boards to de liver a channel separation of gt 105dB for a three dimensional sound stage Amplification At its core is an innovative voltage amplification stage that c
9. e towel Please do not use any solvents or liquidities Service by a qualified person required if the mains cable or the mains connectors are damaged foreign substances or liquidity have entered the 530 the 530 has seen rain the 530 seems to malfunction the 530 has fallen to the floor or the housing is damaged Seite 5 soulution nature of sound A A 3 Scope of delivery Integrated amplifier 530 Remote control Power cord Phono Termination Plug User manual 4 Rear side RIGHT PRE OUT LEFT SPEAKER RIGHT Mains A Connect the integrated amplifier 530 with the mains After switch on the 530 changes to operating condition OFF red LEDs in display consumption lt 0 5W A Only switch off the mains connection in operating condition OFF Input IN 1 IN2 B amp Input IN 3 IN 4 C Seite 6 Integrated amplifier 530 User manual a a B Use top quality cables for the connection to your source components For long ca bles we suggest using the balanced connections Phono MC Input IN 5 D If required the subsonic filter RIAA IEC can be activated A dip switch controlled resistor network allows for optimal adjustment of the termination impedance Micro Switch Open SI S2 S3 S4 S5 S6 Impedance in Q 1000 500 405 300 215 100 20 Ah Never connect a line source to the input IN 5 Pre Out E Gain O Volume 80 INI amp IN2 IN3 amp INA IN 5 Phono Balanced Out XLR 10dB 16dB 0dB Unbalanced Out RCA
10. en the battery tray on the rear side Insert the batteries into the tray as indicated Ensure correct polarity of the batteries Close the tray with corresponding screw Dispose the exhausted batteries Seite 10 Integrated amplifier 530 User manual A a ES Program Mode General The integrated amplifier 530 can be adjusted to your individual setup It is already programmed with default settings Further programming is not mandatory We recommend to adjust the Start Volume and to set the Max Volume Function Push on the Prog button switches the integrated ampli fier 530 between operating mode and programming mode Timeout after 10 seconds a ay Rotating of the Select knob allows selecting the desired Program Function Push on the Select knob for approval of the selected function Now the value domain of the selected Pro eram Function is active red LEDs in display Rotating of the Select knob allows for adjusting the de sired value Push on the Select knob for approval of the respective value j j y o o 3 E o o E o a 3 gt a 3 gt Seite 11 soulution 7 1 Seite nature of sound a EEE u Program Functions Function STHET MODE LIME 3 START IMPUT IM ii STHRT UOLLUME mu DIM VOLUME aki 3 MAS UOLLME i i BALANCE A ne 2m ee MAME IH 2 SEND 12 Values NORM Master LINK Slave AUTO Master IN 1 IN 2 IN 3
11. g L Several Program Functions allow adjusting the 530 to your individual requirements The Prog button switches the 530 to Program Mode Volume M The Volume knob controls the functions Volume Input Select and is used for the Program Mode Volume The 530 has a volume control range of 79 dB We suggest limiting the maximal volume level w x Volume Dim A short push de activates the Volume Dim function Dis play for example D 20 As long as the Volume Dim function is active the volume can not be altered T Change to Input Select Mode gt W m gt dl Input Select The new input can be selected and will be activated after timeout of approx 3 sec e Display IR receiver N The display shows all relevant information of your integrated amplifier 530 Seite 9 soulution nature of sound a VE 6 Remote control Taste Pre Modus CD Modus 1 IR transmitter Operation until 5m distance and angel of 45 2 3 A Y Volume 4 DIM u Volume Dim Play Pause 5 6 gt Select Next Previous track 7 Enter function for Program Mode 8 P De activates Program Mode 9 x Mute 10 ON OFF 11 2 Open Close 12 PRE Activates PRE Mode 13 CD Activates CD Mode Change of Remote Ctrl ID Press the respective buttons for approx 5 seconds ID 1 4 6 gt 5 10 ID 2 4 6 P 5 amp 9 Exchange of batteries 2 x AAA Op
12. n without any ad justment for volume or balance Integrated amplifier 530 User manual a lt Safety advice 4h User manual Mains supply Cabling Transport Packing Operation Cleaning Service Follow the safety advices Keep this user manual Exclusively use 3 phase power cords with ground conductor Unplug the 530 from the mains in the following cases before you manipulate with cables before cleaning during thunder storms before you leave for longer periods While manipulating with cables the 530 has to remain discon nected from the mains Wrong cabling may cause damages to your 530 and loudspeakers Excessive volumes due to inappropri ate handling may cause hearing damages Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving cart apparatus combination to avoid in jury or tip over In order to omit condensation of water inside your integrated am plifier 530 let it warm up within the packing Please keep the original packing for future transports Never run your integrated amplifier 530 with opened housing with closed cooling slots with high ambient temperatures gt 40 C close to heat sources like radiators etc with extremely high humidity for example in humid cellars close to water Sink bathtub or similar equipment Use a soft and dry towel We suggest using a non abrasive micro fibr
13. onsists of linearized amplifiers operating up to a cutoff frequency of 80MHz Current amplification is done in three stages each with a narrow almost linear operating range Powersupply Four cutting edge switched mode power supplies deliver 2 400W of audiophile quality power They feature high performance filtering at the input and output and six high speed soulution voltage regulators to deliver considerably more stable power than any conventional transformer based technology Volume control The 530 s volume control uses only high precision low noise metal foil resistors and it controls both the volume and balance To block switching peaks during vol ume changes which may be hazardous to power amps the 530 is equipped with a second volume control with PGA Programmable Gain Amplifier Active only during the volume control process it is similar to a potentiometer and enables the volume to be adjusted smoothly without clicks As soon as the new desired level value has been selected the unit returns control to the precision resistors Pre Out The soulution 530 integrated amplifier is equipped with pre out connections which enable subwoofers tape recorders or other amplifiers to be driven directly by the 530 s preamplifier section by passing the power amplifier section Surround mode Surround mode allows users to optimally integrate the 530 with AV systems In sur round mode the input signal by passes the preamplifier sectio
Download Pdf Manuals
Related Search
Related Contents
TSR Router Menu-Driven User Interface User Manual 2.97 Manual de instalación y mantenimiento Triton Riel GX EPSON CSCBN12B 専用プリンタ台(キャスター付)取り付け Supermicro P4SCi ValveTrain Spring Thing User Manual à la loupe ÉLODIE BANCE Spectra Studebaker SB6060 User's Manual NetBook NetBook User Guide Honda GXH50 User's Manual Smeg CE6IPX Instructions for Installation and Use Copyright © All rights reserved.
Failed to retrieve file