Perma2™ User Manual - Giatec Scientific Inc
Contents
1. Insert the prepared sample assembly into the cell and fasten the nuts Step 4 Place the second piece of the cell as described in the figure above Carefully pass the bolts through the holes on the corners and place the washers and nuts Using an appropriate wrench tighten the bolt nut combination Giatec Scientific Inc 10 Perma2 User Manual Ready to test Cell front view Filling the Test Cell In order to fill the cell containers place the cell such that the filling inlets are facing upward Fill the right container with black color jack with 3 0 NaCl and the left container with red color jack with 0 3 Normal NaOH solution Fill the test cell containers with NaOH and NaCl solutions Giatec Scientific Inc 11 Perma2 User Manual DO NOT close the filling inlets during the test DO NOT fill the test cells with the liquids when the test is running Leakage Test Once the test cells are filled up with the solutions the leakage test must be conducted as follows Control the level of liquids inside each container If the level of the liquids is not constant within ten minutes or if any dripping is observed below the cell there may be a leak between the gasket and the specimen surface or between the test cell and connectors Any leakage problem should be fixed before starting the test If the leakage is between the gasket and the specimen surface try tightening the bolts and refilling the cell co
2. test cell Left Cell Block End Right Cell Block End Liquid Solution Filling Inlet Rubber Gasket Temperature Sensor Inlet Steel Bolt Spacer Ring e e iS O Giatec Scientific Inc Perma2 User Manual DEVICE OPERATION Before starting the test make sure that the concrete specimens meet the requirements of the standards Then the concrete specimen should be installed in the test cell proeprly In order to run a test follow the step by step instructions below Preparing the Test Cells Step 1 The stainless steel wire mesh must be placed inside each test cell s cup and the corresponding connector must be tightened to provide a firm electrical connection between the mesh and the connector The bolts with provided washers should be inserted into the holes located at the four corners of the cell Steel Bolt and Washers Place the wire mesh inside the cell Tighten the connector Stainless steel mesh Place the steel wire mesh inside each Test Cell container Step 2 Place one rubber gasket at one end of the specimen Then place the spacer ring around the specimen Push the second rubber gasket to the other end of the specimen Make sure that the spacer ring is located right at the middle of the concrete sample by adjusting the location of the rubber gaskets Giatec Scientific Inc 9 Perma2 User Manual Place the gasket and the spacer Step 3 Place the assembled unit into the test cell
3. Depending on the selected test method the appropriate Data Monitor form will appear on the screen ASTM C1202 The Data Monitor form for the ASTM C1202 test methods helps the user control the device and log the test data It provides a user friendly environment to view the real time test data as well as the visualization of the data real time plotting option Time mA T C Time I mA TC Time 1 mA T C Time 1 mA TC Message Log ASTM C1202 Test Method Control Keys On the top of the form the user can find the control keys The control keys are set to be inactive in light grey color when no channel is selected for the test As soon as the user selects the test channel s the Start key will be enabled More information on the Control Keys is provided in the following table Giatec Scientific Inc 28 Perma2 User Manual e dar After selecting test channel s After the first set When the test is successfully Save completed or after pressing Stop e Soon after After pressing Timer According to the ASTM C1202 the total duration of the test is 6 00 hours A timer will appear on the top right side of the form showing the remaining time of the test Test Channels and Data Monitor a Select Channel In order to perform the test the user must select the channels that are connected to the device Click on the check marks in order to select the test channels b Sample ID Once you have checke
4. ADVISED OF THE POSSIBILITY OF SUCH DAMAGES BECAUSE SOME JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES THE ABOVE LIMITATION MAY NOT APPLY TO YOU FURTHER TO THE EXTENT PERMITTED BY LAW IN NO EVENT SHALL GIATEC S LIABILITY AS TO ANY AND ALL DAMAGES ARISING OUT OF THIS AGREEMENT OR THE USE OF SOFTWARE EXCEED THE AMOUNT PAID BY YOU FOR THE RIGHT TO USE THIS SOFTWARE Export Controls This Software is subject to the export control laws of Canada the United States and applicable export and import control laws of other countries You agree to comply with and use the Software in a manner consistent with such applicable laws All rights to use the Software are granted on condition that such rights are forfeited if you fail to comply with this Agreement General Provisions This Agreement constitutes the entire agreement between you and Giatec and supersedes any prior agreement concerning the Software Giatec is not bound by any provision of any purchase order or any other type of correspondence written or verbal Should any court of competent jurisdiction find any provision in this Agreement to be illegal unenforceable invalid or to be overreaching in whole or in part and for any reason such illegal unenforceable invalid or overreaching provisions or part thereof shall be stricken from this Agreement and such provision shall not affect the legality enforceability or validity of
5. Manual THE WARRANTY SET FORTH 15 EXCLUSIVE AND NO OTHER WARRANTY WHETHER WRITTEN OR ORAL IS EXPRESSED OR IMPLIED GIATEC SCIENTIFIC INC SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Please refer to the complete Terms and Conditions of Giatec s products for more details The information contained in this document is subject to change without notice O Giatec Scientific Inc vii Perma2 User Manual SAFETY INSTRUCTIONS This chapter contains important safety instructions that the user must follow for operation and storage of Giatec Perma2 Read the following safety information before any operation to ensure your safety and to keep the instrument in good condition Keep the manual in a safe place for future reference SAFETY SYMBOLS In order to ensure the safety of the operator and increasing the service life of the instruments pay attention to safety precautions described in this manual These messages are indicated by a A symbol throughout this user manual WARNING Identifies conditions or practices that could result in injury or loss of life CAUTION Identifies conditions or practices that could result in damage to Giatec Perma2 or to other properties ATTENTION Refer to the User Manual GENERAL GUIDELINES 1 Always follow basic safety precautions when using this product to reduce risk of injury from fire or electric shock 2 Read and understan
6. TERMS OF THIS AGREEMENT BY CLICKING ON THE I ACCEPT THE TERMS IN THE LICENSE AGREEMENT RADIO BUTTON BELOW YOU ON BEHALF OF CUSTOMER AGREE TO AND ARE LEGALLY BOUND BY THE TERMS AND CONDITIONS OF THIS AGREEMENT IF YOU DO NOT AGREE WITH AND DO NOT WISH TO BE LEGALLY BOUND BY THE TERMS AND CONDITIONS OF THIS AGREEMENT DO NOT CLICK ON THE I ACCEPT THE TERMS IN THE LICENSE AGREEMENT RADIO BUTTON AND THE INSTALLATION PROCESS WILL STOP Copytight Proprietary Protection The Giatec Software the Software and the Documentation all of the online help files and manuals and all of the printed material included with this Software are owned by Giatec and are protected by Canadian United States and international copyright laws and international treaty provisions You must treat this Software like any other copyrighted material with the exceptions outlined in the following License Grant Any violation of this agreement will automatically terminate your right to use this Software and you must immediately return it to Giatec Giatec trademarks contained in the Software are trademarks or registered trademarks of Giatec in Canada the United States and or other countries Third party trademarks trade names product names and logos may be the trademarks or registered trademarks of their respective owners You may not remove or alter any trademark trade names product names logo or other proprietary notices legends symbols or labels in
7. be turned off and short cir Message will be showed on display Turn off the device and remove the short circuit before restarting the test Disconnected Sensor If the temperature sensor is not connected to the test device or if the temperature sensor is damaged a DC message will appear in front of the channel number under the temperature column As soon as the temperature sensor is appropriately connected to the device the temperature value will appear on the LCD display Temperature error in Channel 4 Giatec Scientific Inc 20 Perma2 User Manual Over Current The electric current on each channel is continuously monitored so that the maximum allowable current is not exceeded The current is limited to 50412 mA if the current exceeds this value the channel will be turned off automatically The Over curr message will appear in front of the corresponding channel name on the display and the channel will be turned off No additional data will be recorded from a turned off channel Over current error in Channel 4 Over Heat If the temperature in the test cell exceeds 90 5 1 C the channel will be turned off and the Over heat message will appear in front of the channel name on the display Over Heat error in Channel 4 If the temperature sensor is not connected to the device or if the temperature sensor is not working properly the overheat check will not work and device will not
8. be able to shut down the channels There is a chance that the test cell can be seriously damaged if it becomes overheated Giatec Scientific Inc 21 Perma2 User Manual DATA MONITOR SOFTWARE Perma2 Data Monitor software can be used to control the measuring device perform the tests and log the test data on your computer In order to be able to use the Perma2 Data Monitor you have to install the software on your PC You should also connect the measuring device to the PC using the USB cable provided DEVICE DRIVER When you connect the Perma21M measuring device to your computer for the first time Microsoft Windows will automatically install the required driver 1f your computer has access to internet pop up message will appear on the lower right corner of the screen Windows taskbar Installina device driver sc Click here for status 9 43 AM Ei i do i Pe AB nom Installing the device driver When the installation has successfully completed a message will appear confirming the installation USB Serial Port COMI stalled successfully LY evice driver software in 9 43 AM E y o Pe all DE ET USB Serial Port successfully installed on the computer Giatec Scientific Inc 22 Perma2 User Manual If your computer is running an older version of Windows De XP or 2000 or if your computer does not have internet access you have to install the driver manually The driver fil
9. charge a nominal re stock fee for any such returns Limitation of Liability Giatec is not liable under any other agreement between End User and a Giatec reseller or distributor for the provision of support to include but not limited to an extended warranty or any support service or repair agreement If found to have breached this Sale Agreement Giatec is not liable for any amount above the aggregate dollar amount paid by Customer for the purchase of the Product under this Sale Agreement Except as provided in the Warranty and to the extent permitted by law Giatec is not responsible for indirect special incidental or consequential damages resulting from any breach of this Sale Agreement including but not limited to loss of use loss of revenue loss of actual or anticipated profits including loss of profits on contracts loss of the use of money loss of anticipated savings loss of business loss of opportunity loss of goodwill loss of reputation loss of damage to or corruption of data or software programs or any indirect or consequential loss or damage howsoever caused including the replacement of equipment and property any costs of recovering programming or reproducing any program or data stored or used with the Product and any failure to maintain the confidentiality of data stored on the product The foregoing limitation shall not apply to death or personal injury claims or any statutory liability for intentional and gross negli
10. the intellectual property of Giatec and respects Giatec s rights as the intellectual property rights holder Customer may not and customer agrees not to or to enable others to copy decompile reverse engineer disassemble attempt to derive the source code of decrypt modify or create derivative works of the Software or any part thereof except as and only to the extent any foregoing restriction is prohibited by applicable law Any attempt to do so is a violation of the rights of Giatec By virtue of this Sale Agreement Customer acquires only the right to use the Software as contained in the Product and does not acquire any rights of ownership All rights title and interest in the Software shall at times remain the property of Giatec Product Disposal Recycling Giatec is unable to dispose of or recycle the Product following use End User may dispose of recycle the Product or arrange for the same through the Giatec distributor or reseller which made the Product sale Any disposal or recycling of the Product must be done in accordance with local government directives Export Customer must comply with all export laws and restrictions and regulations of Canada Furthermore Customer will not export or allow the export or re export of the Product in violation of any such restrictions laws or regulations Additionally Customer agrees to comply with the above and represents and warrants that it is not located in under the control of or a r
11. the remainder of this Agreement This Agreement is governed by the laws of the Province of Ontario and any disputes or claims arising hereunder shall be under the exclusive jurisdiction of the courts situated in the City of Ottawa Province of Ontario Giatec Scientific Inc 48 GIATEC SCIENTIFIC INC 301 MOODIE DRIVE SUITE 302 OTTAWA ON K2H 9C4 CANADA PHONE 1 613 240 7451 FAX 1 613 280 1544 SUPPORT GIATECSCIENTIFIC COM WWW GIATEC CA Version 1 0 Printed in Canada
12. units and cables unless damage has occurred due to a defect in materials or workmanship b to cosmetic damage including but not limited to scratches dents and broken plastic on ports c to damage Giatec Scientific Inc 41 Perma2 User Manual caused by accident abuse misuse neglect or failure to properly maintain to include but not limited to water damage and or condensation ot improper temperatures during storage or improper installation d to damage caused by electrical disturbances or acts of God to include but not limited to civil disturbance war flood fire rodents or insects e where manufacturer s serial numbers and security labels have been removed from the Product and f to damage caused during shipment due to Customer s improper packaging from Customer to Giatec in the case of Product returns for repair Giatec disclaims all other warranties express or implied including without limitation implied warranties of merchantability fitness for a particular purpose or against hidden or latent defects Giatec s responsibility for warranty claims is limited to repair or replacement Giatec reserves the right to modify this Warranty at any time at its sole discretion and with notice to Customer Giatec does not warrant that the operation of the Product will be uninterrupted or error free Giatec is not responsible for damage arising from failure to follow instructions relating to the Product s use This
13. EE E E Update Driver Software USB Serial Port COM17 How do you want to search for driver software gt Search automatically for updated driver software Windows will search your computer and the Internet for the latest driver software for your device unless you ve disabled this feature in your device installation settings sl SED AA A e AA VV VV gt Browse my computer for driver software Locate and install driver software manually Select Browse my computer Select the Driver provided on the software CD and click on Next to install the driver File Action View Help 3 15 BrA S F RS e USB Serial Port COM1 Browse for driver software on your computer Search for driver software in this location gram Files x86 Intel Android Device USB driver Include subfolders gt gt gt gt gt gt gt gt gt gt gt gt D win aa gt Let me pick from a list of device drivers on my computer This list will show installed driver software compatible with the device and all driver software in the same category as the device Select the driver file and browse for the file on the CD Giatec Scientific Inc 24 Perma2 User Manual INSTALLING DATA MONITOR SOFTWARE Insert the Perma2 Data Monitor software CD in your computer s CD ROM drive The Setup file is an autorun application If the autorun did not start automatically you can start the setup by clicking on the s
14. KAGE CONTENTS Part Oty Picture Perma2 Measurement Device 1X Test Cable Pair 4X Black amp Red Cell Block End 8X Verification kit 1X Spacer Ring 4X Giatec Scientific Inc m Perma2 User Manual USB Cable 1X o PS o em e Stainless Steel Wire 8X Mesh Rubber Gasket 8X Perma2 Data 1X Monitor Software Giatec Scientific Inc tv Perma2 User Manual Power Cord 1X Please note that the images above are for illustration purpose only and might not be in scale Giatec Scientific Inc Vv Perma2 User Manual WARRANTY Limited Warranties Giatec warrants the Product against defects in materials and workmanship under normal use the Warranty for a period of 12 months from the Delivery Date the Warranty Period on the condition that the Product has been completely paid for Unless as otherwise mandated by local law the Warranty Period does not restart if Customer receives a replacement appliance and or replacement Software This Warranty does not apply a to consumable parts such as batteries Plexiglas cell units and cables unless damage has occurred due to a defect in materials or workmanship b to cosmetic damage including but not limited to scratches dents and broken plastic on ports c to damage caused by accident abuse misuse neglect or failure to properly maintain to include but not limited to water damage and or condensation or improper temperat
15. Smart Concrete Testing Technologies GIATEC SCIENTIFIC USER MANUAL ON S E pi y NaOH mme 3 NaCl h H Temp N K lt gt d sr Rapid Chlori i o o CH4 gt TM Perma2 RAPID CHLORIDE PERMEABILITY TEST Perma2 User Manual TABLE OF CONTENTS PACKAGE CONTENTS aaaaaaannensennnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn Ill WARRANTY A US VI SAFETY INSTRUCTIONS ucccceeeeeeeeeeeeeeeeeeeeeeeeennnennnnnnnnnnnnnnnnnnnnnnnnnn 1 SE IN i EE aca talon manatee 1 GENERADA ecc 1 ID NICE AND o 1 INTRODUCTION TO Giatec Rermai ennnnnnnnnninicininonananannnnonnnannnnnnnnnn nos 4 A aa nt tn tt mette cuite 5 MEASUREMENT CONCEPT a a 5 DA een ee ae res eR ee 6 DEVICE OPERATION arran a at eee a 9 TURNO EE ts ER 13 DEVIC SRT EE 14 AAS EIE DI RE 14 DACE YERE ATON ee 15 SCREEN CON IRAS EE 15 PERTORM TOF TP oroa EAT 16 MESSAGES EE 19 DATA MONITOR SOFTWARE 22 AA A eee O ee ehe 22 INSTATLING DATA MONITOR SORT WARE EE 25 USING DATA MONITOR SOFTWARE EEN 26 Eeer 34 DEVICE Y ERTEICA TON esse 36 O Giatec Scientific Inc 1 Perma2 User Manual EE o A D O O O 36 EE 37 NAIN TENANCE sense teten 39 SERVICE E 399 REPLACEMENT asa 39 Perma2 TECHNICAL SPECIFICATIONS 40 GENE EN 40 OPERATING CONDITIONS Saskia 40 TERMS AND CONDITIONS OF SALE 41 SALE AGREEMENT EXHIBIT A END USER SOFTWARE LICENSE 47 O Giatec Scientific Inc 11 Perma2 User Manual PAC
16. Warranty is voided immediately if repair modification to include upgrades expansions or usage or addition of non manufacturer parts or accessories alteration or other service is attempted other than by Giatec In this regard the integrity of the appliance casing aka the box should not be violated for any reason unless expressly authorized by Giatec in writing Technical Support Giatec will provide technical support to Customer in accordance with the then current support policy in effect and in accordance with the Warranty provided herein unless full payment for the purchase of the Product is not received Giatec will respond to Customer support problems by phone or by email inquiry If a support problem cannot be rectified via phone or email Customer will be provided with return instructions Customer agrees and understands that it may be necessary for Giatec to collect process and use Customer data to perform the support and repair obligations identified herein This may include the necessity to transfer data to affiliate third parties that are contracted with Giatec to assist in meeting these obligations In doing so Giatec will 1 protect and keep confidential such information 11 not use such information for reasons Giatec Scientific Inc 42 Perma2 User Manual other those discussed above and 111 not sell distribute or pass on such information to any third party Repair Customer should carefully inspect the Produc
17. al Perma2 TECHNICAL SPECIFICATIONS GENERAL Type Value Applied Voltage 6020 1 V Range of Current Measurement 0 500 0 1 A Or 0 2 whichever greater Temperature Measurement Range 0 100 1 C Measurement Channels 4 Short Circuit Protection System Yes Data Display on LCD Yes Timer Display on LCD Yes LCD Display Area 65 mm X 33 mm Dimensions of Device 280 mm X 240 mm X104 mm Weight 2 Kg When the ASTM C1202 test is operated OPERATING CONDITIONS Type Value Operating temperature 156456 Operating humidity 30 80 Storage temperature 0 70 C Operating voltage current 100 240 V 50 60Hz Giatec Scientific Inc 40 Perma2 User Manual TERMS AND CONDITIONS OF SALE SALE AGREEMENT Please read this Sale Agreement before using the Giatec Scientific Inc Giatec product the Product By finalizing Your purchase order You the purchaser of the Product and if applicable any end user End User on whose behalf You are making this purchase for You and the End User are hereafter collectively referred to as Customer Customer and Giatec are hereafter together referred to as Parties agree to be bound by and accept the terms and conditions provided below If You and or the End User as the case may be disagree with these terms and conditions do not finalize Your order or if the order has been placed return the Product immediately upon receipt without using it Payment Purchas
18. ampling intervals respectively and 1 is the electric current Amperes Giatec Scientific Inc 17 Perma2 User Manual Sample Calculations If the current is recorded at 30 min intervals the total electric charge can be calculated as O A 800 7 21 21 21 30 160 b ASTM C1760 in this test the value of electric current will be displayed at the end of the 60 second test period The user needs to record the results as there is no onboard memory and turn off the device in order to set up the next series of test samples During the sample replacement the device must be kept off to avoid electrical shock hazard To avoid electric shock the device must be turned off before connecting any cables and cells Placing the temperature sensor in the positive cell might cause a serious damage to the device if the epoxy on the tip of the sensor is damaged Therefore it is highly recommended to place the supplied temperature sensor in the cell with black jack containing sodium chloride solution that is connected to the negative terminal Giatec Scientific Inc 18 Perma2 User Manual MESSAGES Perma2 has been designed and tested to the highest standards to ensure the safety of the user and the instrument Several safety measures have been implemented in the device Depending on the situation one or more of these features might prevent the unit from continuing its normal functions The channels are des
19. cted to the appropriate connection terminals Also make sure that there is no short circuit The main power switch of Perma2 is located on the back panel of the device Turn the switch from O off to I on The LCD screen on the front panel will turn on after a few seconds the Test Parameters menu will appear on the LCD screen Giatec Scientific Inc 13 Perma2 User Manual The default test method is set to ASTM C1202 If you want to perform the test according to ASTM C1760 you should change the test method using the options available in the Menu Test Parameters on the LCD display DEVICE SETUP The system setup can be changed by pressing the Menu l key on the front panel The menu options will then appear on the LCD display Using the Up and Down keys on the front panel the user can ACCESS these options Main Menu on the LCD display TESTING STANDARD The user can change the test method by selecting either of the two available standard test procedures ASTM C1202 or ASTM C1760 You can select the test method by using the Up Jand Down keys on the front panel Press SelectB to choose your test method Giatec Scientific Inc 14 Perma2 User Manual Testing standard on the LCD display DEVICE VERIFICATION The verification kit is a useful accessory kit that can be used to ensure the appropriate functionality of the Perma2 system In order to verify the device select the verification opti
20. d a test channel the Sample ID box will be activated Fill in the text box to identify the sample ID This will help to document the test results better c Real Time Data When the test starts the current and temperature values will be measured by the device The data will appear on the screen next to the Current and Temperature boxes At each step and for each channel the software will calculate the total Charge that has passed through the concrete sample Giatec Scientific Inc 29 Perma2 User Manual d Data Log Table The real time data logging will be displayed in tabulated format right under the channel box Message Log A message log box located at the bottom of the form will log any errors that might have occurred during the test The user can scroll the box to view multiple messages E a e File Controls Tools Help Current mA Charge C I mA T C I mA T C I mA T C MER 398 4 D C 319 4026 23 9 19 1683 23 19 20 01 3979 D C 19 2001 4021 23 1609 23 19 21 01 3978 D C 192101 4019 23 1558 23 Message Log 2014 11 13 19 19 00 CH 2 Channel is tumed off due to No Current ASTM C 1202 Test Running Alternatively the user can use the control keys under the Controls menu item to proceed with the test Giatec Scientific Inc 30 Perma2 User Manual ASTM C1202 Test Method ASTM C1760 The control keys and data monitor sections are customized to help the user with th
21. d all instructions in the documentation that comes with Giatec Perma2 3 Observe all warnings and instructions marked on the product DEVICE HANDLING LN OS Giatec Perma2 device is a delicate testing instrument The electronic parts and test cells are sensitive components Please handle them with care e Do not place any heavy objects on Perma2 Measurement device e Avoid severe impact or rough handling that might damage the device or the cells e Do not disassemble Perma2 Giatec Scientific Inc 1 Perma2 User Manual e Install the product in a protected location where no one can step on or trip over the power cord and in a location where the power cord cannot be damaged OPERATION WARNING AC Input voltage 100 240 V 50 60Hz Leave at least 100mm 4 room behind Perma21M to allow for ventilation Do not perform measurement on or connect the test leads to circuits directly connected to Mains Live circuit Keep the instrument in a place where the chance of spilling liquids on the device is negligible Only replace the fuse with the exact one mentioned on the marking at the back of the unit Avoid touching the output terminals or end metal parts of the test cables when the device is ON CLEANING THE INSTRUMENT A ATTENTION Unplug this product from wall outlets before cleaning Use a soft cloth dampened in isopropanol alcohol or water Do not use chemicals or cleaners containing harsh pr
22. discovers that the Warranty is inapplicable due to the reasons provided above see the Limited Warranties section hereof the Product will not be repaired and will be returned to Customer at Customer s expense unless Customer authorizes and pays for repair Whether Customer authorizes repair or not Giatec reserves the right to charge a No Fault Found fee where the Product is found not to be defective due to any fault of Giatec Any Giatec reseller or distributor involved in the purchase of the Product is not authorized to make any modification extension or addition to the Limited Warranties provided by Giatec herein although any such reseller Giatec Scientific Inc 43 Perma2 User Manual or distributor may provide its own warranty in addition to the warranty coverage provided by Giatec Refund Policy and Product Return On a case by case basis Giatec reserves the right to authorize a full refund of any Product purchase made where a refund is requested within 30 days of the Delivery Date In such cases where a refund is approved End User will return the Product to Giatec if the End User made such order itself If the Product was ordered by a distributor or reseller such distributor or reseller will coordinate with Giatec for the return of the Product In either case Customer is responsible for shipping and insurance charges and any damage to the Product which takes place en route to Giatec Giatec reserves the right to
23. e ASTM C1760 test procedure In this test method the value of electrical current at the end of 1 minute test will be displayed for any selected channel s AE ASTM C1202 Test Method O Giatec Scientific Inc 31 Perma2 User Manual Control Keys On the top of the form the user can find the control keys The control keys are set to be inactive when no channel is selected for the test As soon as the user selects the test channel s the Start key will be enabled More information on the Control Keys is provided in the following table e After y the Start test y a Soon after Timer CG Ben the Start After pressing the Timer According to the ASTM C1760 the total duration of the test is set to 1 00 minute A timer will appear on the top right side of the form showing the remaining time of the test Test Channels and Data Monitor a Select Channel In order to perform the test the user has to select the channels that are connected to the device Click on the check marks in order to select the test channels b Sample ID Once you have checked a test channel the Sample ID box will be activated Fill in the text box to identify the sample IDs This will help to document the test results better c Length Diameter Before starting the test fill in the dimensions of the test sample the length and diameter of the cylinder These values will be used to determine the bulk conductivity of concrete
24. e Price and Associated Charges Payment must be made at the time of order unless otherwise agreed to by the Parties Customer will pay the total purchase price plus shipping and handling if any as specified on the emailed invoice Customer is also responsible for all taxes related to this purchase and to the import of the Product if applicable to include but not limited to all sales taxes value added taxes import taxes customs duties and any other similar taxes imposed by any governmental entity Title Risk of Loss Title to the Product passes to Customer when the Product is paid for in full However Giatec bears all responsibility for loss of or damage to the Product during initial shipment after purchase and until Product is received by Customer unless Customer selects 1ts own mode of shipping In repair cases risk of loss is borne by Customer for return of the Product but by Giatec following repair and upon return to Customer Limited Warranties Giatec warrants the Product against defects in materials and workmanship under normal use the Warranty for a period of 12 months from the Delivery Date the Warranty Period on the condition that the Product has been completely paid for Unless as otherwise mandated by local law the Warranty Period does not restart if Customer receives a replacement appliance and or replacement Software This Warranty does not apply a to consumable parts such as batteries Plexiglas cell
25. e inside a cell reaches 90 5 1 C the corresponding channel will be turned off automatically The duration of the test is also controlled by an internal clock system which will disconnect the power from the channels once the test 1s completed DEVICE OVERVIEW Giatec Perma2 has two main components A measuring device Fig 2 and 3 and four concrete sample cells Fig 4 The measuring device can be used as a stand alone equipment to perform the tests It can also be connected to a personal computer PC using the USB connection pott The Data Monitor software provided in the package controls the device and also records the measurement data In this section the key functions of these components are described Measuring Device The front panel of the measuring device includes channel ports see Fig 2 Items 1 2 and 3 Display and the control keypad The test cells are connected to the measuring device using the cables included in the package Giatec Scientific Inc 6 Perma2 User Manual Front Panel Figure 2 Front Panel View 1 Positive Connection Port 2 Negative Connection Port 3 Temperature Sensor Connection 4 LCD Screen 5 Control Keypad Back Panel Figure 3 Back Panel View 1 Power Switch 2 Power Inlet 3 Cooling Fan 4 USB Communication Cable Port 5 Fuse Box O Giatec Scientific Inc Perma2 User Manual Test Cell Q Figure 4 Assembled Test Cell The assembled Perma2
26. e is located on the Perma2 Data Monitor CD In order to install or update a previously unsuccessful installation go to the Device Manager In Windows you can access Device Manager under System in the Control Panel File Action View Help AE B m E 4 Ey WS6 HA Mi Computer a Disk drives E Display adapters E DVD CD ROM drives De Human Interface Devices C IDE ATA ATAPI controllers amp Keyboards A Mice and other pointing devices amp Monitors amp Network adapters KR Portable Devices 7 Ports COM amp LPT D Processors Sound video and game controllers Mi System devices Universal Serial Bus controllers USB Virtualization Device Manager window Right click on the USB Serial Port and select Update Driver Software ci AENA AA LL 4 Ey WS6 HA Ni Computer ca Disk drives amp Display adapters E DVD CD ROM drives 1 Human Interface Devices lt q IDE ATA ATAPI controllers Keyboards D Mice and other pointing devices amp Monitors amp Network adapters KE Portable Devices 1 Ports COM amp LPT H p USB Serial Part COM17 DI Processo Update Driver Software amp Sound vi Disable JM System d Universal USB Virtu Scan for hardware changes Uninstall Properties Update Driver Software Giatec Scientific Inc 23 Perma2 User Manual Click on Browse my computer for driver software File Action View Help Ze zeg A T
27. e of arbitration shall be Ottawa Ontario Canada The language of the arbitration shall be English For the purposes of this arbitration this Sale Agreement shall be governed by and construed under Ontario law as such law applies to agreements between Ontario residents entered into and to be performed within Ontario Canada The decision of the arbitrators shall be binding upon the parties hereto and the expense of the arbitration including without limitation the award of attorneys fees to the prevailing party shall be paid as the arbitrators determine The decision of the arbitrators shall be executory and judgment thereon may be entered by any court of competent jurisdiction Any non English language translation of this Sale Agreement is done for local requirements and in the event of a dispute between the English and any non English versions the English version of this Sale Agreement shall govern Giatec Scientific Inc 46 Perma2 User Manual EXHIBIT A END USER SOFTWARE LICENSE IMPORTANT PLEASE READ THE TERMS AND CONDITIONS OF THIS SOFTWARE LICENSE AGREEMENT CAREFULLY BEFORE AGREEING TO INSTALL THE SOFTWARE THIS IS A LEGAL AGREEMENT BETWEEN GIATEC AND THE END USER CUSTOMER GIATEC IS WILLING TO LICENSE THE SOFTWARE WITH WHICH THIS AGREEMENT IS PROVIDED THE SOFTWARE TO THE CUSTOMER UTILIZING THE SOFTWARE ONLY ON THE CONDITION THAT THE CUSTOMER ACTING THROUGH YOU THE CUSTOMER S AUTHORIZED AGENT ACCEPT ALL OF THE
28. esident of any restricted country Giatec Scientific Inc 45 Perma2 User Manual Entire Agreement This Sale Agreement constitutes the entire understanding of the Parties as to the subject matter hereof and supersedes all prior offers agreements arrangements negotiations and understanding written or oral between the parties relating to that subject matter Severability Assignment If any provision of this Sale Agreement is held to be unenforceable for any reason the legality or enforceability of the remaining terms shall not be affected or impaired The failure of Giatec to act with respect to a breach of this Sale Agreement by Customer or others does not constitute a waiver and shall not limit Giatec s rights with respect to such breach or any subsequent breaches Giatec expressly reserves the right to assign this Sale Agreement and to delegate any of its obligations hereunder Customer may not assign delegate or otherwise transfer whether by operation of law or otherwise this Sale Agreement or any of Customer rights or obligations hereunder without the prior written consent of Giatec Giatec may assign the provision of repair services to third parties Governing Law Dispute Resolution All disputes arising out of or in connection with this Sale Agreement shall be finally settled under the Rules of Arbitration of the International Chamber of Commerce by one or more arbitrators appointed in accordance with the said Rules The plac
29. etup icon in the installation CD e y Downloads Perma2 Installer y Search Perma2 Installer Organize El Open Share with Burn New folder 3 Favorites Le HZ Desktop DotNetFX40Client de Downloads Windowsinstaller3_1 23 Dropbox z E PERMA2 DM INSTALLER msi Date modified 11 20 2014 6 07 PM File folder 11 20 2014 6 07 PM File folder 11 20 2014 11 32 Windows Installer 7 156 KB amp OneDrive setup exe 11 20 2014 11 32 Application 418 KB E Recent Places A Libraries Documents d Music Pictures amp Videos D s setup exe Application Date modified 11 20 2014 11 32 AM Size 418 KB Date created 11 20 2014 6 07 PM Click on Setup to start installing the Perma2 Data Monitor The setup wizard will guide you through the rest of the installation Follow the instructions on your screen to install the software This process may be different depending on the version of your operating system Windows XP 2000 7 or 8 Following a successful installation a Perma2 Data Monitor icon will be created on your desktop Click on this icon to run the software Giatec Scientific Inc 25 Perma2 User Manual USING DATA MONITOR SOFTWARE Click on the Perma2 Data Monitor icon on the desktop to launch the software Alternatively you can open the software from the Programs in the windows Start Menu The device should be connected to the PC with the USB cable and tur
30. gent acts and or omissions Not For Resale The Product may not be purchased for resale purposes by Customer unless Customer is a legal and authorized reseller of Giatec products Giatec Scientific Inc 44 Perma2 User Manual High Risk Uses Customer will not purchase the Product for usage in connection with any high risk or strict liability activity including without limitation air travel space travel firefighting police operations vehicle operations power plant operations or power generation applications transport management systems military operations rescue operations hospital and medical operations or the like whereby such usage could cause or contribute to damage to property or injury to persons Software License The Product is and contains the intellectual property of Giatec and is protected by Canadian U S and international copyright patent trade secret laws and international treaties This Agreement is not intended to grant and shall in no way be construed to grant to Customer any rights in the intellectual property of Giatec including the intellectual property in the Products The Customer shall obtain a non exclusive license to use the software contained in the Product the Softwate only in accordance with the terms of the Software License Agreement attached hereto as Exhibit A and the Customer shall agree with its terms prior to installing the Software Customer acknowledges that the Software is
31. he measuring device the corresponding LED light will remain off during the test No data will be recorded for these channels A turned off message will appear in front of the channel number If there is any error a specific error message will appear Refer to the ERROR section of this user manual for information regarding the troubleshooting of the malfunctioning channels At any time during the test the user can terminate the test by pressing the STOP key A message will appear on the screen to verify the termination of the test By pressing the YES key the test will be terminated For an incomplete test using the recorded data the total electrical charge until the termination time will be calculated and displayed on the screen The user can choose to continue the test by pressing the NO 2 key The end of the test When the test is completed the channel s will be turned off for ASTM C 1202 the total electrical charge will be calculated and displayed in front of the channel number for ASTM C1760 the current value after 1 minute will be displayed in front of the channel number a ASTM C1202 in this test the total electrical charge Coulomb for each specimen is calculated by integrating the area under the current curve This area can be calculated using the trapezoidal rule l Q Anl 21 21 1 Where O is the total electrical charge Coulombs f and Af seconds are the total duration of the test and s
32. ice is appropriately set to Firmware Upgrade mode the following screen will appear KZ 1 Select the HEX and EEP upgrade files 2 Press O for upgrade Select Upgrade files Select the appropriate Hex and Eep files provided by Giatec Scientific Inc Click on the Firmware upgrade button to start Upon the successful completion the following message will appear on the display and the device will return to the test mode EE Instructions 1 Select the HEY and EEP upgrade files 2 Press O for upgrade L el Firmware Upgrade Successful O Giatec Scientific Inc 35 Perma2 User Manual DEVICE VERIFICATION A verification kit can be purchased with Perma2 that can be used to ensure the appropriate functionality of the device The verification kit contains various electrical circuits that generate known electrical charge when it is tested by the device To ensure appropriate functionality of the measurement system verify the device with the verification kit from time to time The verification procedure may be repeated as required If the device does not pass the verification procedure the device should be returned to Giatec for hardware calibration The hardware calibration is also advised to be conducted once per year to ensure the appropriate functionality and accuracy Of the measurements It is noted that the optional verification practice will not assure the required accuracy of the system and the
33. igned to work individually therefore these safety features will only apply to the channel experiencing trouble In this case a message will appear on the display Turn Off The channel s will automatically be turned off if no electric current is drawn following the start of the test In this case a Turned off message will appear in front of the channel name on the display This condition could arise in one or more following conditions e Test cables are not connected to the cell or the device or are loose e No liquid was poured into test cell e The sample were not fully saturated before running the test Communication error in Channel 4 If all four channels are disconnected the turned off message will appear for all channels The user has to press the stop key to terminate the test The user is then asked to turn off the device using the main power key on the back panel and check the test cells and wires Giatec Scientific Inc 19 Perma2 User Manual ADC Err When the current measurement circuit does not function properly the ADC Err message will appear on the display To resolve the issue try turning off the device first and then turn it on after a few seconds If the issue is not resolved contact Giatec customer service Short Circuit If the positive and negative test leads are short circuited to each other by error when connecting them together the channel with this fault will
34. ith the testing standards requirements each channel must be supplied by a controlled precision Time Management Block Short Circuit Protection Block Over Current Temperature Protection Block Control Block res rs rs ps Lo Power Source Temp Sensor 60 0 0 1 V Cut off Switch Shunt Resistor Current Measurement Block Figure 1 Electrical Block Diagram of Perma2 device Giatec Scientific Inc 5 Perma2 User Manual 60 0 1 DC voltage source The electrical current passing through the cell is measured through an accurate and stable shunt resistor The electrical potential over this shunt resistor will be used to calculate the current passing through the cell Each channel is protected against short circuit to prevent damage to the device and the test cells in case of faulty connection in the output circuitry The short circuit protection system is also designed to reduce the fire hazard from excessive temperature rise in wires during a prolonged short citcuit period In addition each output port is monitored continuously for its current consumption to limit the maximum allowable current to 504 5 mA A current consumption in excess of this limit would automatically turn off the overloaded channel The temperature of each test cell is continuously monitored with the accuracy of 1 C using the temperature sensors to prevent overheating that might damage the test apparatus When the temperatur
35. ned on before launching the Data Monitor softwate The Perma2 Data Monitor home window will appear on the screen The menu strip box at the top of this form helps the user to perform different tasks Data Monitor home screen In this section the function of these menu items File Controls Tools and Help will be described File Before starting a test the user must start a new session In the File menu click on New to define a new session Giatec Scientific Inc 26 Perma2 User Manual File Menu A wizard will appear on the screen The user has to fill in the necessary information to start a new test session ene Controls Tools Help New Session Wizard Output files Name and Destination In the wizard form the user has to enter a valid file name and select a destination address The file name will be used to create the output file The destination address is the location where the output file will be saved in The user can also change the destination folder Giatec Scientific Inc 27 Perma2 User Manual Additional Information The user is encouraged to fill in the name of the operator for their records Any additional notes can be added in the Notes box Select Test Method The test method can be selected using the dropdown menu bar at the bottom of this form The user can select from the two available standard test procedures ASTM C 1202 and ASTM C 1760 Press OK to continue
36. ntainers If the source of leakage is between the cell and connectors try tightening the connector if it is possible Otherwise use silicon glue to seal the space between the connector and the cell You may also need to adjust the position of the rubber gaskets and ensure they ate properly located within the Plexiglas cell part to fix the leakage problem To avoid electric shock all the cells must be leak free before running the test Disconnect the test cells from the measuring device before checking or fixing the leakage Giatec Scientific Inc 12 Perma2 User Manual Connect the Test Cells to the Measuring Device To avoid electric shock the device must be turned off before connecting any cables and cells Each cell should be connected to the corresponding channels on the front panel The red connector of the cell should be connected to the red terminal of the channel using the red cable In a similar way connect the black terminal to the black connector on the other half of the cell The temperature sensor should also be placed inside the NaCl container The other end of the temperature sensor cable should be connected to the designated terminal on the front panel d NaOH emm NaCl bo 0 3N 3 N Connection diagram shows the details of the cable connections TURN ON Perma2 Before turning on the device make sure that the cable sensors and test cells are conne
37. oducts such as benzene toluene xylene and acetone OPERATION ENVIRONMENT A ATTENTION Do not block ventilation holes on the top of the device Place the instrument in a well ventilated area Avoid blocking the fan output at the rear of the instrument Giatec Scientific Inc 2 Perma2 User Manual STORAGE ENVIRONMENT MA ATTENTION e Location Indoor e Relative Humidity 5 to 90 e Temperature 0 C to 70 C O Giatec Scientific Inc Perma2 User Manual INTRODUCTION TO GIATEC Perma2 Giatec Perma2 is a re engineered laboratory test device for measuring the resistance of concrete to the penetration of chloride ion The test procedure is consistent with different standards including e ASTM C1202 AASHTO T277 e ASTM C1760 The device is capable of measuring the electrical charge passing through a standard concrete sample The Perma2 device can be operated as a stand alone unit or controlled using the Data Monitor PC software The measurements can be used in the performance based quality control of concrete materials Measurements can also be used to estimate the chloride diffusion coefficient of concrete for the purpose of service life prediction The ASTM C1202 test provides an indication of concrete resistance to the penetration of chloride A widely accepted qualitative relationship see Table 1 between the electrical charge measured according to ASTM C1202 and the long term chloride penetrability
38. of concrete was originally proposed by Whiting et al 1981 Table 1 Chloride ion penetrability based on charge passed ASTM C1202 Chloride 56 Day Rapid Chloride Permeability Charge Passed Penetration Coulombs Low 1 000 to 2 000 An alternative procedure to the test was proposed and standardized ASTM C1760 to predict the bulk electrical conductivity of saturated specimens of hardened concrete The results reveal a rapid indication De in one minute of the concrete s resistance to the penetration of chloride by diffusion The results of this test method can be also related to the Giatec Scientific Inc 4 Perma2 User Manual apparent chloride diffusion coefficient that is determined using ASTM C1556 test method APPLICATION Perma2 is a laboratory device for testing the durability of concrete that is or has been exposed to chloride contaminated environment including Concrete s ability to resist chloride ion penetration ASTM C1202 AASHTO T277 Bulk electrical conductivity of concrete ASTM C1760 Performance based quality control of concrete Estimation of the chloride diffusion coefficient of concrete Estimation of the chloride migration coefficient of concrete Service life design of concrete structures Estimation of the remaining service life of concrete structures MEASUREMENT CONCEPT Fig 1 depicts a typical functional diagram for one of the four channels available on the device In accordance w
39. on in the Main Menu and follow the instructions Device verification on the LCD display SCREEN CONTRAST In order to adjust the contrast of the device display use the Up key to increase the contrast or the Down r key to reduce the contrast Screen contrast on the LCD display Giatec Scientific Inc 15 Perma2 User Manual PERFORM THE TEST In the main menu select the test method you want to use ASTM C1202 or ASTM C1760 Test Parameters Method ASTM C1202 Test Parameters Method ASTM C1760 Duration hh mm Duration hh mm 06 00 00 01 ASTM C1202 ASTM C1760 Press the Start key on the front panel to start the test all four channels will be checked by the system to ensure their appropriate functionality before starting the test Turned On Turned Off e CH 1 Cc d A O Ki CH 3 A oo A CH 4 o e A A O 0 H 2 A TIO If the channel is working properly the values of the current and temperature will appear in front of the channel number on the display and the red LED lights on the front panel will turn on Ch I mA T C Timer Ch I mA T C Timer 50 2 25 0 50 2 25 0 0 1 25 5 hh mm ES 25 5 hh mm 201 2 24 5 00 01 Turned off L 2 3 lt Ul e 24 5 04 25 4 350 3 25 1 Measured current and temperature during the test Giatec Scientific Inc 16 Perma2 User Manual For those channels that are not connected to t
40. pment of the Software to Customer General and specific limitations on this warranty are described in Giatec s Warranty statement and are incorporated by reference THE WARRANTIES DESCRIBED HEREIN AND OR ACCOMPANYING PRODUCTS ARE IN LIEU OF ALL OTHER WARRANTIES OR CONDITIONS AND SAVE AS OTHERWISE PROVIDED HEREIN GIATEC MAKES AND THERE ARE NO OTHER WARRANTIES OR CONDITIONS OR REPRESENTATIONS OF ANY KIND WHETHER EXPRESSED OR IMPLIED AND GIATEC EXPRESSLY DISCLAIMS THE IMPLIED WARRANTIES OR CONDITIONS OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE AND THOSE ARISING BY STATUTE OR OTHERWISE IN LAW OR FROM A COURSE OF DEALING OR USAGE OF TRADE GIATEC DOES NOT REPRESENT OR WARRANT THAT THE PRODUCTS WILL MEET ANY OR ALL OF ANY ORGANIZATION PARTICULAR REQUIREMENTS THAT THE OPERATION OF THE PRODUCTS WILL BE ERROR FREE OR UNINTERRUPTED Any written or oral information or advice given by Giatec distributors agents or employees will in no way increase the scope of this warranty No Liability for Consequential or Incidental Damages and Limitation of Liability IN NO EVENT SHALL GIATEC ITS SUPPLIERS OR DISTRIBUTORS BE LIABLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES WHATSOEVER INCLUDING WITHOUT LIMITATION DAMAGES FOR LOSS OF PROFITS BUSINESS INTERRUPTION LOSS OF INFORMATION OTHER PECUNIARY LOSS OR ATTORNEY FEES ARISING OUT OF THE USE OF OR THE INABILITY TO USE THIS SOFTWARE EVEN IF GIATEC OR ITS SUPPLIERS OR DISTRIBUTORS HAVE BEEN
41. refore the calibration procedure is necessary to be conducted regardless of the verification practice The verification of the device can be performed from the main menu option on the front panel of the device Alternatively you can verify the device by using the Data Monitor softwate Using the Front Panel From the main menu go to the Device verification option and press the Select key Select Device Verification The user will be asked to connect the ports of the verification kit to the corresponding channels on the front panel of the device Giatec Scientific Inc 36 Perma2 User Manual Select Device Verification Press the startB key to initiate the verification process Once the verification process is completed the results will be displayed on the LCD screen Device Verification Results Using Data Monitor Software The user can also verify the accuracy of the device using the Data Monitor software by connecting the device to the verification kit Connect channels 1 to 4 to the corresponding channels on the front panel of the device Giatec Scientific Inc 37 Perma2 User Manual Ex Firmware Upgrade O Device Verification Device verification If the channels Pass the verification test a Pass message will appear in the text box For channels failing the test a Fail message will appear Perma2 Data Mont EHER Instructions 1 For channels 1 to 4 connect the verification kit to
42. samples Giatec Scientific Inc 32 Perma2 User Manual Message Log A message log box located at the bottom of the form will log any errors that might have occurred during the test The user can scroll the box to view multiple messages Le Wl amp el File Controls Tools Help ASTM C1760 Test Method Running Giatec Scientific Inc 33 Perma2 User Manual FIRMWARE UPGRADE If there is any update for the firmware of the Perma2 device the firmware upgrade files will be sent to the customers These files will be used to upgrade the firmware of the device You can access the firmware upgrade from the Tools menu item Firmware Upgrade The user has to turn on the device in the Firmware upgrade mode To do so hold the ge Key 4 and press the power switch on the back ES B GE Tools O O Firmware Upgrade Instructions 1 Turn off the device If the device is already turned off go to the next step 2 Press and Hold UP key on the front panel and turn on the device The Firmware Upgrade will appear on the LCD 3 Press button to check the status of the device Device Info Hex File Serial Number Cd Description EEP File ams Kee Firmware Upgrade Giatec Scientific Inc 34 Perma2 User Manual If the device is not in the correct mode the user is asked to follow the instructions and try again Click on the verify button to check the status of the device If the dev
43. t upon its delivery Customer should maintain all original packaging upon receiving the Product until the Product has been installed and is found to be in proper working order If the Product arrives to Customer the date of arrival is referred to herein as the Delivery Date damaged or defective at initial delivery Customer must notify Giatec Technical Support within 30 days from the Delivery Date of the condition of the Product and obtain return instructions if needed Product must then be returned immediately to Giatec for repair or replacement at Giatec s discretion Giatec will then arrange for delivery of temporary or permanent replacement Product Customer is responsible for properly packing the return shipment of the Product Giatec will arrange for shipping and insurance If Customer fails to notify Giatec within 30 days of the Delivery Date 1 the Refund Policy below will not apply 11 Customer will bear the cost of returning the Product for repair and 111 damaged Product will not be accepted If during the Warranty Period as described herein but following the initial 30 day period the Product is not working properly Customer must contact Giatec Technical Support to confirm the problem and obtain return instructions if needed Customer will pay shipping and insurance costs when returning the Product for repair If the Product is returned for repair or replacement at any time following purchase by Customer and Giatec
44. the Software License Grant Giatec grants you a nonexclusive license to use this Software on a single dedicated computer You may copy this Software onto the hard disk of this computer and make one copy for archival purposes You may not make copies of the Software for any purpose other than what is stated above You may not copy the Documentation for any reason You may not reverse engineer disassemble decompile or attempt to discover the source code of the Softwate You may not modify the Software or create derivative products using this Software You may not sublicense rent or lease any portion of the Softwate You may transfer your rights under this agreement on a Perma2nent basis to another person or entity provided that you transfer this License Agreement all original and updated Software and Documentation and that you not retain any copies of the Software or Documentation You must notify Giatec in writing of your transfer and the recipient must also agree to the terms of this License Agreement If you want to share the Software on a network please contact Giatec to request a Network License Agreement Giatec Scientific Inc 47 Perma2 User Manual Limited Warranty Giatec warrants the physical compact disk s on which the Software is distributed to be free from defects in materials and workmanship and that the Software will function in substantial accordance to the specifications for a period of one 1 year from the date of shi
45. the device using provided cables 2 Click the gt button This process may take a few seconds 3 Upon completion the verification test results will be shown for each channel Device Verification Giatec Scientific Inc 38 Perma2 User Manual MAINTENANCE Repairs and servicing not covered in this manual should only be performed by qualified personnel Periodically wipe the case with a damp cloth Do not use abrasives or solvents SERVICE If Perma2 does not start check the power supply cord to see if it is connected properly If Perma2 still does not work properly review this manual to make sure you are operating it correctly If Perma2 malfunctions first try to check its functionality using the verification kit If that fails call our technical support line number provided on the back of this manual Only after consulting with our technical support department pack the device securely in its original shipping container and forward it to the nearest service center Please include a description of the malfunction REPLACEMENTS When servicing Perma2 use only the replacement part specified The USB communication cable is intended to be used only by Perma2 device and connecting it to other instruments will damage the cable To order replacement parts call Giatec Scientific Inc using the number provided on the back of the manual or on the back of the device Giatec Scientific Inc 39 Perma2 User Manu
46. ures during storage or improper installation d to damage caused by electrical disturbances or acts of God to include but not limited to civil disturbance war flood fire rodents or insects e where manufacturer s serial numbers and security labels have been removed from the Product and f to damage caused during shipment due to Customer s improper packaging from Customer to Giatec in the case of Product returns for repair Giatec disclaims all other warranties express or implied including without limitation implied warranties of merchantability fitness for a particular purpose or against hidden or latent defects Giatec s responsibility for warranty claims is limited to repair or replacement Giatec reserves the right to modify this Warranty at any time at its sole discretion and with notice to Customer Giatec does not warrant that the operation of the Product will be uninterrupted or error free Giatec is not responsible for damage arising from failure to follow instructions relating to the Product s use This Warranty is voided immediately if repair modification to include upgrades expansions or usage or addition of non manufacturer parts or accessories alteration or other service is attempted other than by Giatec In this regard the integrity of the appliance casing aka the box should not be violated for any reason unless expressly authorized by Giatec in writing Giatec Scientific Inc vi Perma2 User