Home
Vigil User Manual
Contents
1. Input sensors terminated 12v sensor pigtail PANEL WARNING LIGHT ALERT Optional 12v boat bilge pump sensing D Shore 110VAC Power BILGE PUMP OVER RUNNING ALERT Shore power sensing AC adaptor with 3v DC output Contact Vigil Marine for Programming commands connects directly to any free and hints for each function switch input SHORE POWER LOSS RECOVERY ALERT 14 OUTPUT RELAY CONNECTION ALTERNATIVE Depending on the model Vigil you are using the output relays have provision for Normally Open and Normally Closed connections Instead of finding and connecting to the relay common to create a positively switched output it is often easier and more convenient to convert the relays to negative switching This is normal practice if you are using Vigil as an engine kill on an outboard motor Converting the relays to negative switching i e connecting the relay common to negative is easy to accomplish by simply inserting the jumpers adjacent to each relay as shown below Your Vigil has two built in 12 volt 1 Amp relays that can be used to drive the coil of a slave relay in order to activate other devices To utilize these relays you will need to either 1 Insert J2 and or J3 to use negative switching initiated by Vigil or 2 Leave J2 and or J3 open then feed a positive or negative into the Vigil relay via the Relay Common and use the appro
2. 5sec Telemetry Ch n Acquire reading Enable Telemetry Ch n Disable Telemetry Ch n Sets up telemetry readout conversion values for telemetry channel n The Ov input is set by xx xx and 3v input is set by yy yy xx xx and yy yy can be 1000 to 1000 Change Text message for telemetry Channel n Eg CTXT2 ADC volts ch 2 volts NB 2 spaces Enable Output 1 This is the main relay ACTIVATION command Requires setup NB After a NOKILL REL1OFF is left set so a F5E won t work until a REL1ON is first issued KILL does a REL1ON automatically so that will work after a NOKILL Disable Output 1 This is the main relay DE ACTIVATION command Enable Output 2 This is the main relay ACTIVATION command Disable Output 2 This is the main relay DE ACTIVATION command ARMS and Activates closes Output relay 1 NB KILL and NOKILL are given full immediate control of the relay so that no other device can interfere with the high priority action required To get overall control they utilize REL1ON and REL1OFF This stops anything else interfering with the function i e KILL OP1REM REL1ON F5E Deactivate open output relay 2 NOKILL REL1OFF De activates amp disables KILL relay Setup command Relay1 can be turned both ON or OFF Setup command Relay1 Turns OFF and remains OFF regardless of F5E REL2ON REL2OFF SIREN NOSIREN Fast access commands ENTER lt gt opcode1 opcode2 ENTER lt gt 88888888 LE
3. Thick red EI P Supply Thick Black Ground Thin Black 7 Signal ground Relay 1 Orange DI Ignition KILL Blue sw Bilge sensor Brown ww 2 Door sensor Relay2 Green o6 Siren trigger Yellow d 6ft cable to probe Vigil Geo Plus 17 Thick red GUDD Thick Black aGrauae Orange sw go Blue Relay 1 Common A Green si 2 W VW Purple Relay ape NC A i Yellow Relay 2 fp D Common a White Relay1 OPS NO t Grey Relay 2 OB N O Vigil Basic QUESTIONS and TROUBLESHOOTING Unit doesn t Check that the SIM Card has been installed activated is working and doesn t respond to require a PIN number SMS Try it in a mobile phone If your phone asks for a PIN Number remove it Test commands the SIM Card is working by sending an SMS message to another mobile phone Make sure the SIM is installed improperly Orient it correctly and make sure the holder is firmly closed Open the unit and make sure the battery is plugged in Check that the numbers you entered into the device registers are correct including country code lf one of the numbers is receiving messages and others are not you can issue a GETPHONE from a phone that is working to see what numbers are loaded in the registers NB The leading sign will be replaced by 00 Try adding the numbers again even a space at the end of a number cannot be seen but will result in a message send failure Check that the syntax of the command you
4. board one at the time Locate the SIMCARD holder as shown in FIG 2 Gently push the silver slide toward main holder body to release Swivel SIMCARD carrier up Insert an activated SIMCARD with the golden contact side facing downwards and the cut corner facing up as shown See FIG 3 Hinge carrier closed Slide silver slide back away from main body to lock Carefully replace the standby battery holder making sure you don t leave the plug under the battery so that it can easily be plugged into the socket TURN VIGIL ON If you have not already done so insert the SIM Card using the instructions noted above To activate the unit take the small white plug from standby battery and slide it into the power socket as shown in FIG 4 This only goes in one way Do NOT force When you do this you may note the small LEDs on the circuit board start flashing They will only flash for the first minute or so and then turn themselves off You are now ready to load the phone numbers Test with just one mobile phone first then load others later as required SETUP AND OPERATING COMMANDS Please Note the following convention used in this manual to describe the commands e Spaces are indicated by lt gt Don t insert any spaces in the phone number itself e The eight 8 s included in various commands are a factory password e The SMS messages commands are not case sensitive Set up your phone to send a text message SMS TO the phone number iss
5. connect a third wire into the TAP engine please consult your engine manufacturer to Vigil connector confirm that this is the correct method of installing an Kil wire aim Engine Kill function on your motor before proceeding This will involve making a wire tap into the KILL switch wire that goes into the engine Electronics Control Module VIGIL GEO provides a THREE Engine KILL diode isolator block Engine IGNITION Kill wire that allows for 3 Engine Kill isolation so turning one off at the key switch does not kill the others Connect the ORANGE VIGIL GEO wire to the Diode common terminal Each diode goes to a separate engine Kill wire Use any of 12 the diodes for any engine Refer to the engine manual or local Dealer for identification of the KILL wire in your make of engine Make sure that it requires GROUNDING in order to KILL the ignition Some modern engines will not KILL with simple grounding of the wire Seek advice and then confirm by running engine and grounding wire before connecting to VIGIL GEO If you are using VIGIL GEO on an outboard engine marine installation please make sure that the link is inserted at Jumper link J2 The J2 link connects the KILL relay RL1 to ground providing the ignition ground that KILLs the outboard ignition If you are planning on using the device to kill outboard ignition by grounding the ignition you must have the small black plastic link jumper inserted see photo J2 is located next to
6. new geofence RADIUS in meters note there is a space between RAD and XxXxX Factory default is 200 m Minimum is 5 meters e g RAD 100 Geofence Distance Report DIST lt gt xxxx where xxxx is the new Distance between reports AFTER a Geofence transgression Factory default is 0 m no report Minimum is 200 meters e g DIST 500 Geofence Time Report Iinterval TIME lt gt xxx where xxx is the Time in minutes between reports AFTER a geofence transgression Factory default and Minimum ts 5 minutes e g TIM 20 Turn the Geofence Off NOSET This turns off the Geofence Position Update YES OPTUS 6 18 PM 17 59 k At any time you can request ET A I EE EEE an immediate position report Dec 20 2012 18 53 by sending 32 028195 115 772591 FIX or POS VIGIL FIX NEW Co 11 Sp 8 km h http maps google com maps Kg This will respond with a f q amp hl en amp t h amp q loc S 32 028195 115 772591 current fix If the GPS receiver is already on and tracking satellites then the message your unit sends will show NEW for the fix If it is not warmed up or it cannot determine its location because it cannot get a GPS fix it will send a report showing OLD while it continues searching the sky for satellites and a NEW fix The OLD coordinates will be its last known position Please note that it may take several minutes to lock a satellite solution and deliver a fix When your V
7. use Vigil in your specific application please don t hesitate to contact us Solutions Centre A B N 40 335 741 635 16 Carlton Loop Canning Vale WA 6155 Tel 0412 958 253 Fax 08 6102 1798 E mail info solutionscentre net au Web www solutionscentre net au LOADING SIM CARD CAUTION Before loading your SIM Card ensure that the SIM Card you are using does NOT require a PIN Number most Telstra SIM Cards are supplied with a PIN Number required each time you start the mobile device If the SIM Card requires a PIN Number you will need to insert the SIM Card into another mobile phone and turn off this requirement before it will work on Vigil If your unit has been shipped with a SIM Card preinstalled then all you need to do is follow the separate instructions to activate it Otherwise you will need to follow these steps to install a SIM Card NOTE YOU MUST disconnect all external power supply connections when changing the SIM Card This may require disconnecting AC adaptors or car battery L 2 Se Hinge SIM carrier up Remove screws carefully slide out ss a FIG 1 board and unclip battery holder FIG 2 Topside Cutcorner UP Insert SIMCARD gold contacts downward i Then hinge e down and lock Remove screws as shown in FIG 1 Carefully slide out the Vigil circuit board Make sure the Battery is disconnected as seen in FIG 4 Remove the black Battery holder by releasing the clips from the main
8. AVE lt gt opcode1 opcode2 LEAVE lt gt 88888888 SOS alarm SOSE SOSD CTXS AKSOS Power settings PLE PLD PGE PGD PWRDEL lt gt nnn CTXPL lt gt message CTXPR lt gt message EXTVOLT lt gt ON lt gt vv vv SET NOSET GFE GFD GPSE Setup command Relay 1 can be turned both ON or OFF SetupCommand Relay Turns OFF and remains OFF regardless of F6E This is a setup command that ARMS Siren relay connection but does NOT activate relay Issues a REL2ON Then use F6E to activate siren relay This is a setup command that DISARMS siren relay connection and de activates Siren relay with REL2OFF Note NOSIREN is a high priority action so uses REL2OFF which overrides all other devices Sets up predefined command string for ENTRY No Password required Activates the ENTRY command string and requires the password Sets up predefined command string for Leaving No password required Eg SMSE SET REL1ON REL2ON Activates the LEAVING command string and requires password Enable SOS activation thro sw 4 Disable SOS activation thro sw 4 Set text for SOS message Acknowledge SOS received Power Loss alert enable Power loss alert Disable Power Good alert enable Power good alert disable Power sense delay of nnnn secs Change Text for POWER LOST message Change text for POWER RECOVERY message Alarm setpoint voltage Note space after ON Must be over 10 volts GPS Functions only applicable to GPS equ
9. Marine accept no liability for the applications or uses made by its products We recommend that you always obey local laws relating to tracking and in particular disablement of vehicles by remote control This can be dangerous and should not be deployed on road vehicles as it can cause serious injury to others Only activate remote engine kill when you have the vessel in sight and it is safe to do so Solutions Centre and Vigil Marine also accept no liability for the use or misuse of its products under any circumstances including GSM network GPS services or device failure for whatever reason Solutions Centre and Vigil Marine also reserve the right to change the specifications functionality and instructions of its products and accessories at any time without notification 19
10. Web www solutionscentre net au E mail info solutionscentre net au Solutions Centre vigil geo geo thermo remote basic installation and User Guide IMPORTANT e Please read this manual carefully and thoroughly before installing and operating your Vigil e Please retain this manual for future reference after reading it thoroughly Table of Contents INTRODUC HON E 2 LOA DING IN OCAR D E 3 TORN VIGE ON sc E E E E E E E E 4 SETUP AND OPERATING COMMANDG 4 EENEG 4 Loading tne SIM Card due CT ne 4 WEE EE eege ectace E aE bi cines E O ens chenanba macy arebene 5 Rss Ville CN Gilet ton E 5 OP ee ER 5 Setting and Using the Geotence 5 Changing Ihe Renee E 6 Geofence Distance Report cccccccccsscccceeeeceeeeeseeecseeesseeeeseeesseeeesecessaeeeseesessaeessaeeesesesseeesueesseeesseeeesenees 6 Geoence Time Ee ele gl 6 ENEE EE 6 Position Beie EE 6 CIR RETTEN 7 RV Se eent el 7 OPM MOR eeler E 7 euer EE 7 Ree eer 8 VVC TNS TEE 8 CUTOUT SOMO RE 8 Fast AGC S elen ANOS ccrratecaeceec asec E A R N E E E E case E 9 SD MIM EE 9 Rail E 9 GPS Functions only applicable to GPS equipped models 9 BR FOI Teac np ic Ma a apg es se Maou oss ss E oe nD apa a cape re nD apa sap 10 SECT FASS CAA E 10 PHONE Pa pars erste Se area age etre ee tds sn tes Goa oes ed waters ee tn ee ote ve edad geese aed teat dre oe gettin lane eee oases 10 BASI INSTALLATION aces ccueecte E A E E A E E E E E S 11 A Determine MOUNTING ee e bacssvcino
11. battery plug and disconnect the power supply when doing this 3 Even though VIGIL can be installed in any craft Bast better including ROAD VEHICLES we strongly Goeie recommend that you NOT connect the Ignition Se KILL function to road vehicles as road vehicles require engine power to provide full steering and Thick braking Killing their ignition can cause a danger RED to other road users ALWAYS have the vehicle or vessel IN SIGHT when you utilize the ignition KILL function and be very careful with its use Vigil cable RED BLACK Boat Battery Connect RED to Positive and BLACK to Negative At same connection point 13 VIGIL GEO TYPICAL BOAT WIRING SUGGESTIONS Multi Engine KILL Wiring To Port Engine Kill wire Cerner engine Relay 1 is for KILL switch To STBD Engine Kill wire Relay 2 is for SIREN Boat battery Boat batter To Vigil ORANGE 7 Positive Negative for up to TRIPLE ground Engine Kill G Ignition KILL tap d Thick Single Engine Kill Black 7 6 Relay 2 Common Vigil cable SIREN STROBE ALARM Zt Not included e Ground Black SCC BE 1 eg 8 Purple Brown and White Switch Ess REED Switch MAGNET MAGNET Bilge sensors Door or Hatch entry sensor Not included at any convenient connector Activate DOOR and HATCH ENTRY ALERT Alert when wet ELECTRONIC HIGH WATER ALERT ENGINE HOUR COUNTER E SOS Button J ad
12. ber Remove Ph Number in entry n Sends list of active phone numbers Set tamper sensing E5CE E5OE Disable Tamper sensing E5CD E5OD Get Firmware Version Acquire Battery voltage and Temperatures Acquire temps Temp acquire 40F to 248F 40C to 120C Set Tamp alarm set points xx Lo YY high 30C to 110C 30F to 230F where F or C is desired temperature scale Reset minimum and maximum temperature log Temp High alert enable Temp High alert Disable Temp Low alert enable Temp Low alert disable Temp Normal alert Enable Temp Normal alert Disable Temp delay of up to 9999 seconds Change text for Temperature LOW alert Change text for Temperature NORMAL alert Change text for Temperature HIGH alert I O contact Switches EnOE EnCE CTXSOn lt gt msg CTXSCn lt gt msg EnDestttt Telemetry ADC TLnA TLnE TLnD TLn lt gt xx xx yy yy CTXTn lt gt message lt gt lt gt units Output Control relays FSE F5D F6E F6D KILL NOKILL REL1ON REL1OFF Enables unit to send an alert when the nominated switch changes to Open where n is the switch number e g Switch 1 OPEN Enable is E10OE Enables unit to send an alert when the nominated switch changes to Close where nis the switch number e g Switch 1 CLOSE Enable is E1CE Change Text message for External Alarm n OPEN to msg Change text message for External Alarm n CLOSED to msg Set switch n DELAY for tttt sec 0 to 9999 sec 0
13. ciosstcoclorssnacdoseedsctnrssnadnertcacknessnadnertbacknessuecdnertiacdoessuecdovssaecdaeesuas 11 B ele fe te E 11 C ET e Ae 6c E 11 D RES ue WI EE 12 E Make Ne COMMC CHONG ege 12 F ONIO fl eaei ae R EESE R E SEE EE shot E ESE AR E RE EEEE AER 12 G Serge leet IOVS SOI S e DE 13 VIGIL GEO TYPICAL BOAT WIRING SUGGESTIONS cece cccccceeeeecceeeeeeeeseeeeeeeseeeeeeeeeeeeeesseaeeeesseaeeeeeeas 14 OUTPUT RELAY CONNECTION ALTERNATIVE scocvecescactocedoacusciensuctiodsbonctadensueedeloesuddtdanbedelacciaiwaseciedebocsuasede 15 VV EE EE CR E 16 QUESTIONS and TROUBLESHOOTING ccc ecccccceccecceeceeceeeeeeceeeceseeeeeeseeeeeeseeeeesseeeeeseaeeesseeeesaaeeesseneeeeas 19 INTRODUCTION Your Vigil is a very powerful monitoring device that can monitor and provide remote control from any mobile phone Some models also provide GPS tracking functionality In order to make Vigil as accessible and as simple to use as possible we have provisioned Vigil at the factory to perform the more common functions out of the box It has many capabilities that we do not mention here so contact us for any special requirements This manual provides you with installation and operating guidelines for the Vigil Geo Geo Thermo and Remote Since the Vigil range of products is so versatile it is impossible to provide you with instructions applicable to every application in a single document If you require any assistance or suggestions on how to
14. de the viciLseT Home geofence radius and thereafter it will send a new position sire ard eat a report every 5 minutes if it has moved more than a f gshi en amp t h amp g loc e SC 31 961195 115 897591 factory set 50 meters from the previous reported position Please Note 1 If the device is stationary and mounted high and clear of anything that provides multiple GPS signal paths then the accuracy of the fixes will be probably better than 3 m However a truck driving nearby or anything else that gives a reflected GPS signal can give rise to false alarms For this reason the default geofence Time based radius is set to 200 metres although it can be altered down to a minimum of 5m You will need to try it in the target environment to see how small the radius can be set without getting excessive false alerts 5 2 If the GPS receiver is already on and tracking satellites then the message your unit sends will show NEW for the fix If it is not warmed up or it cannot determine its location because it cannot get a GPS fix it will send a report showing OLD while it continues searching the sky for satellites and a NEW fix The OLD coordinates will be its last known position 3 You can program it to send a position report based on time distance or BOTH after a transgression You can change these factory presets with the following commands Changing the Geofence Radius RAD lt gt xxxx where xxxx is the
15. ence mode lt is therefore recommended that you use a small regulated trickle charger to keep your jet ski battery charged if you are leaving it unused You may need to perform some tests to determine how long it takes for VIGIL to flatten the battery C Check the signal Check the signal strength with the GETSIG Command before you commit to a location to verify that it is receiving solid GPS and GSM signals in the area you plan to mount the unit IVI lec 20 2012 18 53 N SSI signal strength index Jer CETE ES GPS Signal Fix 1 to 3 satellites 3 is good See ee SAT 10 SAT number of satellites being tracked 1 12 B GSM Signal 1 is low 5 is great 11 D Tamper Switch Vigil comes equipped with an internal Tamper Sensor switch Insert foam Mount the magnetic pad supplied as shown button between and if the unit is moved away from the pad 7 Vigil and mount it will immediately send an alert NB ONLY apply glue to the PAD end marked GLUE HERE E H DO NOT apply glue to the Vigil Case or the Vibration Tamper alert will not work cushioning foam button Allow 24 hours for glue to set E Make the connections Your Vigil unit can be powered by a 12 volt system The internal battery charges off of the ships power and it is recommended that the unit be connected directly to the batteries with a 1 2amp slow fuse fitted between the unit and the power supply Next referring to the wir
16. entered this number cannot be removed If you don t add the Device Phone number Vigil will still work but the TIME will only be updated from the network when an SMS message transfer occurs List Registered Phones Vigil allows for a FOUR entry phone book which must consist of the full phone number required to call within the network or roaming area provided by the SIM Card To check the four recipient phone numbers stored in Vigil send the following command GETPHONE a ph2 ph3 0061412345678 ph4 Vigil will send you an SMS text showing a list of the four entries in its phonebook NB The leading sign will be replaced by 00 in the register Removing a Phone Number Send the following text to your vigil REMOVEPHONEn lt gt PASSWORD n is ph 1 to 4 VIGIL Removed Phone i e g REMOVEPHONE2 lt gt 88888888 this removes ph 0061412345678 L stored as 2 To change a number you can load the new number over the old using ADDPHONE GPS EQUIPPED MODELS Setting and Using the Geofence Your Vigil unit can be set to notify you if it moves beyond a preset distance from the position where you activate the Geofence the home location To set the home position and activate the Geofence SMS the following to your Vigil SET EE Vigil will respond with a confirmation SMS that it has a new HOME location for the geofence Your Vigil will now send a transgression report if it moves outsi
17. g This affords great ease and flexibility of mounting Vigil is capable of transmitting through fibreglass and teak decks more than an inch thick but like any antenna metal objects will interfere with transmissions Choose a spot inside the boat or in an exterior locker or cowling or other position that is not under heavy machinery metal boxes excessive decking or carbon fibre as these will shield the GPS antenna from satellite communication d In general the higher up and the closer to the deck the better the reception will be The unit works best if mounted in a vertical position as indicated by the arrow on the unit and the Top sticker on the device The arrow should be pointing to the sky and the Top sticker should be on top of the unit for maximum reception The unit will work best if mounted in a location where the unit will generally be in this orientation regardless of the boat s tack or motor trim in normal conditions Mount the unit where you can access power and easily run wires to the sensors you will be monitoring VIGIL is made to operate at temperatures up to 140 deg F 60 deg C however the standby battery life will be Shortened at these higher temperatures VIGIL should be fitted at least 1 inch 25 mm CLEAR of the crankcase or other HOT engine parts The lead acid battery on most Jet skis and motor bikes is often very low capacity and may run flat after a short period of time when VIGIL is in geo f
18. igil unit sends a position Fix it delivers the Course co in degrees True Soeed Sp in knots default or configurable to miles or kilometres and lastly a hyperlink to Google Map that contains the Latitude and Longitude in a degrees and decimal degrees Cursor your internet enabled smart phone browser over the hyperlink and click to see the current position displayed on Google Map You can copy the link straight onto Google Earth if running on a PC or use Bluetooth to transfer the hyperlink from your cell phone to your PC where you can click on the hyperlink and view the position on a map EXPANDED COMMAND SET Following are some commands that Vigil responds to There are many more specialised commands available that are not listed here If you have a requirement that is not listed or need help understanding the listed Opcodes please email info solutionscentre net au System controls ADDPHONEn lt gt 88888888 lt gt Ph number DEVPH lt gt dev ph Number REMOVEPHONEn lt gt 88888888 GETPHONE TAMPER NOTAMPER GVER Information Acquisition INFO Temperature monitoring TEMPA TEMPRESET lt gt F or C lt gt XX YY TEMPRESET THEP THD TLE TLD TNE TND TEMPDEL lt gt nnnn CTXTL message CTXTN message CTXTH message Add new phone number to phone registry location n 1 to 4 Always enter numbers in international format E g for Australian mobile numbers replace leading O with 61 set Device s SIM Card phone num
19. ing diagram connect the wires from the Vigil unit to your external sensors and accessories A few notes to consider when wiring your unit a Any of the sensors float switch motion sensor smoke sensor etc must be a dry contact type sensor or output less than 3vDC to the Vigil unit when the circuit is closed b In order to sense a voltage e g 12v always use a Vigil 12v sensor pigtail to isolate the Input circuit from the 12v boat voltage These sensors offer an optically isolated contact signal to any Vigil switch input Vigil Black 12 Volt Boat Ground ve Vigil Switch oat ve Sense input Ground c Bilge sense wires float switches and entry switches magnetic reed switches can be daisy chained to accommodate monitoring multiple entry or bilge areas Vigil inout sensor wires can be setup for normally open or closed monitoring e Distance is generally not an issue when running your sensor wires f The output wires are the relay switches for controlling external devices or remote shutoff of the motor These relays are set to be normally open and close to ground The relays are rated for 1 amp and can power small LED type applications from the onboard power If higher amperage or a voltage other than the power supply of the unit is required a slave relay should be used F Ignition Kill Connection for one two or three engine installation If you want to implement the IGNITION KILL function you will likely need to
20. ipped models Enable Geo Fence GFE Disable Geofence GFD holds GPS Rx OFF Enable Geofence Disable Geofence Enable GPS receiver GPSD Disable GPS receiver FIX Acquire immediate fix GPSA Report REP lt gt nnn d opcode opcode opcode Where nnn d is the time between reports in hours and 1 10 hour e g REP 20 INFO RCOUNT TEMPRESET Max 30 chars Note commas Set nnn d Zero to disable i e REP 0 SETSERVICEDUE lt gt ddmmyy nn were ddmmvyy is due date and nn days before date to alert Default is 7 SETSERVICEMESSAGE lt gt message User set text message Switch Assignments Sw 3 Can be used for Countdown of operating hours contact us for related commands Sw 4 SOS call Must first be activated Sw 5 Tamper switch Activate up sw 5 for both OPEN OR CLOSE PHONE APP lf you would rather push a button on your mobile phone than remember the opcode to send to your Vigil you will find SMS RC available on both the iPhone or Android stores useful 10 BASIC INSTALLATION A Determine mounting location This is an important step that requires careful forethought in order to get the best results out of your unit B Considerations The following instructions describe issues to consider when installing the device in a boat The same principles need to be considered when installing the unit in any other environment a b Vigil has all its antennas enclosed within its weatherproof housin
21. issued is correct Unit is sending 1 If you have reduced your geofence radius from the factory default 200 metres you frequent or your unit is obstructed from a clear view of the sky then your geofence radius Geofence false may be too small Try increasing the radius using the command GFR ddddd alerts GPS where ddddd is the selected radius equipped Send the unit a GETSIG command to see if you are getting a strong GPS models only signal If the signal is consistently poor try mounting the unit in a different location If there is no GPS Fix try turning on the GPS by issuing the command GPSE On an outboard installation when the motor is tilted up and not in use turn it so that the unit is on the upward facing side so that the GPS antenna has a clear view of the sky All our products have very high gain GPS antennas but accuracy can be affected by many variables including atmospheric conditions unit location time of day sun spots surrounding building amp terrain etc Check to see if the GPS antenna cable has come unplugged from the circuit board Open the unit and carefully plug in the antenna to the circuit board The GPS antenna is located above the battery and the plug is on the left side of the unit the plug receptacle is located in the upper left hand corner of the circuit board If you have difficulties please email us at info solutionscentre net au or phone on 0412 958 253 NOTE Solutions Centre and Vigil
22. priate External Output to feed switched current to your relay Insert J2 to ground relay 1 used for engine KILL or negative switching Next to it is J3 used to ground relay 2 for siren or other negative switching Removing link s enables direct access to Relay normally open contacts however the other side of the contacts are in the wires under the shrink tubing white for relay 1 KILL and Grey for relay 2 Siren J2 KILL Link AASR sm JS not used SL Battery Socket e ege ES es i J3 Siren Link Contact your supplier for program instructions to set Siren in activation J6 Tamper sensor link Insert Beka mode lOr if KILL is needed to independently Blo use onboard tamper sensor lt operate other devices Gi SH S Acs T 9 DT geet 1 D EE Ee h 3 ies Oe f We Factory Reset f Ap Relay 2 O Be Careful mae under ana O E a Bo 4 S LED On Off ssh LORS dimple switch gt _ ESS weer We ck N 28 Hinge up i SIM Card e carrier TETY H SE SO e e KEE e SE S D f X ao of r z yom BI A i 7 mm k GEI DH l em e an ir GPS Antenna socket P H e gang Links snot used 15 WIRING ASSIGNMENTS Each Vigil model has slightly different wiring assignments Please ensure you identify the wiring assignments applicable to your model from the following diagrams Please note that only 7
23. the relay RL1 which is the relay closest to the silver button cell on the top side of the VIGIL PCB board If the Kill is being used to say operate a fuel solenoid on a diesel or petrol engine then this link may not want to be grounded Please contact your supplier for confirmation G Electronic Bilge level sensing VIGIL GEO comes with the BLUE bilge sense wire contigured to alarm when wetted in water NB it may not work in very pure unsalted water This allows its use as a bilge sensor Use any two wire MARINE screw terminal to connect to the BLUE bilge sense wire and to the BLACK ground wire Shorting the black to the blue will produce a bilge alert You can then screw the sensing terminal in the bilge at a point and level that is ABOVE the normal Bilge pump float switch That way if the bilge pump cannot keep up with water inflow or fails the sensing terminals will get wet and set off the alarm Note that these terminals can false alarm if they get wet They will only reset when totally dry IMPORTANT TVs Transient Voltage Suppressor 1 Unless you are powering this unit from a DE regulated power supply always utilise the Connection diagram Transient Voltage Suppressor TVS supplied with your unit or available from your supplier ee Connect the Red positive end and the Black eae negative end to the same power connection point TM as the unit 2 NEVER change or load a SIMCARD while power is still connected to VIGIL UNPLUG BOTH the
24. ued with the SIMCARD that you just loaded into Vigil The SIMCARD phone number will have been issued along with the SIM card by the network provider The first message you must send Vigil is your mobile phone number Send the following text Adding Phone Numbers ADDPHONEn lt gt 88888888 lt gt country code area code your mobile phone number n is ph 1 to ph 4 eg ADDPHONES 88888888 61423456789 This is loaded as ph 3 Now send this off Vigil should respond with a confirmation 0 ea escape message If no response is received within about 3 Dec 20 2012 18 53 minutes it means it either did not receive the message or there was a syntax error in the command VIGIL New Phone Added If this worked you can close the unit up again carefully 0061412345678 making sure the o ring is clean and seated properly Incorrect installation of O ring voids warranty You can store up to four phone numbers using the same command Loading the SIM Card Phone Number Most SIMCARDS do not have a phone number stored internally so you may want to load the number assigned to the SIMCARD by the network provider Do this py sending Vigil the following command e g DEVPH 121234567899 i ae 4 DEVPH lt gt country code area code SIMCARD phone number NB This will cause Vigil to send itself an occasional SMS to update the time Depending on your chosen mobile phone plan you may be charged for these SMS messages Once
25. wires are typically exposed at the end of the cable To access the remaining wires carefully remove the heat shrink at the end of the cable Vigil AC adaptor Thermo DC inline socket Thick red St Thick Black Thin Black Relay 1 Orange o s external output relay 1 Blue __swi input sensor 1 Black Brown l White nominees fpPUrsensor2 Input sw3 l Relay2 Input sw4 Purple Green DEL external output relay 2 Telemetry 2 DIE Ae Brown Telemetry 3 White ton 6ft cable to probe Relay 1 common White Vigil Thermo Vigil AC adaptor Remote i DC inline socket Thick red e Thick Black d Thin Black Orange external output relay 1 ae input sensor 1 Black Brown Input sensor3 mat white input sensor 2 Input sensor 4 BE oe external output relay 2 Yell Relay 2 Common sos Grey Telemetry 2 Brown hit Telemetry 5 Ee white Relay 1 common Vigil Remote 16 Vigil Geo Black Spare input sw3 If SOS trigger sw4 Purple Brown Spare input zw White yellow N C Relay 2 op6 Kill common Relay 1 White Siren common Relay 2 HIE Vigil Geo Plus Spare sense sw3 SOS trigger sw 4 Purple shore Power input zw LOTE Output control 2 SEY Thick red ER Supply Thick Black S Ground Thin Black m ilac Signal ground Relay 1 A ange C 5 Ignition KILL Blue Bilge sensor Brown Sw 2 Door sensor Relay2 Green op6 _ Siren trigger Vigil Geo
Download Pdf Manuals
Related Search
Related Contents
CDPM 7753 (41901927) Bedienungsanleitung OUT LIMITS DSS Digitales GSM Hayter Mowers BCL2250C RS User's Manual Copyright © All rights reserved.
Failed to retrieve file