Home
GSM Gateway User Manual
Contents
1. 1 second set the Total cycle time ms 10 steps to 100 1000ms Power up time Time of operation during the cycle time E g if the cycle time is set to 1 second and you want the Gateway to power the POTS during 50 of the time set the Power up time ms 10 steps to 50 500ms 8 2 5 Tone generation The GSM Gateway can generate line tones on the POTS according to different country specific preferences There are a few pre programmed countries France Germany Great Britain Italy and Spain Germany and Italy are the same setting and this is also the EU recommendation for PSTN tones When using the GSM Gateway with the EC II Flex please use German Italian or Spanish settings even if the EC II Flex is installed in other countries 8 2 6 Dial tone 2 battery failure For setting the GSM Gateway to generate the dial tone 2 indicating a battery failure set the Dial Congestion tone battery fault to 425 Hz 1000 250 250 250 ms This is default active Page 12 of 13 9 Technical Data Parameter Size L x B x H Weight Protection class External power Power consumption Battery type Battery power consumption GSM module Antenna Line voltage on hook Polarity reversal Operating temperature Air humidity Approvals Tone indications Dial tone 1 Dial tone 2 battery failure Congestion tone Ring tone Ring back tone Busy tone Connections Telephone Antenna connector DC
2. GSM Gateway SMS from GSM Gateway The GSM Gateway will acknowledge a correct programming by returning a SMS as above In this example when the battery is changed it will generate the following SMS from the GSM Gateway Bacen TOR eO Ihab acre 452 SMS from GSM Gateway Both functions described above are switched off by sending the following SMS to the GSM Gateway Balarm off Balarm OFF Bares OFF SMS to GSM Gateway SMS from GSM Gateway Page 7 of 13 ROCOM Ere The SMS is acknowledged with a SMS from the GSM Gateway The Battery replaced SMS Bares function described above can be switched off separately by sending the following SMS to the GSM Gateway Balarm ON Bares OFF SMS to GSM Gateway SMS from GSM Gateway The SMS is acknowledged with an SMS from the GSM Gateway 7 2 Dial tone 2 The dial tone 2 indicating a battery alarm low battery voltage indication to the lift phone is default activated but can be turned off In case the function is deactivated the GSM Gateway will always use dial tone 1 when the line is taken off hook To deactivate the dial tone 2 battery alarm low battery voltage indication dial tone off send the left side SMS to the GSM Gateway The Gateway will return the answer on the right side Dial Teme7 OFF Dia CONEA OnT SMS to GSM Gateway SMS from GSM Gateway To reactivate the dial tone 2 battery alarm low battery voltage indication dial tone send the left
3. ROCOM er GSM Gateway User Manual Table of contents 1 Content of delivery oo ee cececcesssscssecsseeeseesecneesessssessssecsessecseesesuassessaecsssascsesseenseseseseesesaecsesseeseeaeenes 2 2 PIN COGG s dicssccccscdscisevissctuascesetiaviswsoeaecebedaesdsescuaecesdduavnastonqnceseduecdaestuaudes cbaavedsctagscasedavettaatamsdusceanesteedunecetes 2 3 DS TANATION ara si sanpscctouseve E E P AA EE ussucededaduasebdasaeedcdaqidvebtasuettes 2 4 Front panel connectors and indications ssssssssessesesssesssssersesreseessssionessesnesresressssisnesrenrisrsseese 3 5 Back panel connectors and INdICAtIONS cc ccccsscessesssessceseceseeseceseccssecssccsscesesesesesescesceseeeaeens 3 6 ECT Vacs acess sic tesscah a E E R N A Scents 4 6 1 Low battery voltage indication 00 cece ecceccesceseeseeeeessesecsseeecsseeseessesecsseesenessaeesesaeeseesesseeaeenes 4 G 2 Battery fault AA ccccseesssseseesessesetessonscesesonsescssontecvescnsseessonsvevesonsenssnonsesvesenssbessensenvesense neds 5 7 SMS TUNCHOMALILY icici Gscetictescees Ascessentnrs E AE AA 5 FD Bette ry ANIM scces ce ovede a E E O 5 KAn T W 6 eager area en ee er ee ree ee eee 8 8 Upgrade TOON ics tesevcessesdcces cassens csnsveces E E sven easedees saadentsdesvterd ots 10 2 1 Firmware upgrades eein TE EET 10 8 2 SUD cian acre a A E E A E a E OA 11 8 2 1 LED control on signal strength seeeseeesressressressreesrerressreseressresererreseresrer
4. device PHONE 1 No PHONE RJ11 1 2 La m 3 Lb 4 5 Back panel connectors and indications an favpbce E Wo e 2 ANT Y ANT SMA connector for the antenna SIM Input of the SIM card GSM Status for the GSM connection when the GSM Gateway is up and running Green LED Page 3 of 13 GSM Indicates OFF Faulty GSM unit 800 ms ON 800 ms OFF No service No connection with GSM or SIM card missing 100 ms ON 1500 s OFF Connection with the GSM network OK Backup power in use ON Normal status Connection with the GSM network OK AC powered 1 and S2 Indications for GSM signal strength Green LED S1 S2 Signal strength OFF OFF Bad ON OFF Good default 15 83 dBm ON ON Very good default 25 63 dBm Flash OFF Good Backup power in use Flash Flash Very good Backup power in use LED levels are programmable in 2 dB steps from 113 dBm to 51 dBm via USB 1258 Manager 12V DC 12V DC No PWR e 9 28 V DC GND RESET Type of RESET activation Power supply Result Short push External Reboot of GSM Gateway Short push Battery GSM Gateway is switched off Hold button for gt 20 s External All settings are reset to factory settings This is indicated by the LED s PHONE and BATT Note Factory reset also changes the PIN code back to the default 1234 if PIN code is in use this may cause the S M card to be locked if a SIM card is mounted i
5. power supply input USB 10 Contact Information Support Tel 49 6106 66000 E mail info rocom gmbh de Data 165 x 140 x 64 mm 558 g with battery and antenna included IP 20 10 28 VDC At rest 12V lt 140 mA 24V lt 75 mA Ongoing call 12V lt 450 mA 24V lt 225 mA NiMH 4 8V 1250 mAh High Temp At rest about 100mA Ongoing call lt 550mA I E 2h including 3 x 3 minute calls Siemens M55i Quad Band 850 900 1800 1900 MHz 50 Ohm SMA connector 870 960 MHz 1710 1990 MHz 48 V DC Yes 5 C to 40 C 30 to 90 RH TBD 425 Hz 10 dBm Continuous 425 Hz 10dBm 1000ms ON 250ms OFF 250ms ON 250ms OFF continuous 425 Hz 10dBm 200ms ON 200ms off 200ms ON 200ms OFF 200ms ON 600ms OFF continuous 25 Hz 40 VRms into 3REN 1500 ms ON 3000 ms OFF 1500 ms ON 3000 ms OFF 200 ms ON 200 ms OFF RJ 11 SMA DC Plug 2 1mm 5 5mm USB 2 0 Mini Rocom Energie und Kommunikationssysteme GmbH Lessingstr 20 63110 Rodgau Germany Phone 49 6106 66000 Fax 49 6106 660066 Homepage www rocom gmbh com Page 13 of 13
6. side SMS to the GSM Gateway The Gateway will return the answer on the right side Page 8 of 13 Dial tone2 Dial Tone2 ON SMS to GSM Gateway SMS from GSM Gateway Page 9 of 13 8 Upgrade Tool The USB interface is used to configure user specific parameters and to upgrade the GSM Gateway firmware The upgrade requires the Windows program 1258 Manager and is available from Rocom GmbH or your local distributor Use a standard USB miniUSB cable to connect the GSM Gateway to the PC Install the 1258 Manager tool on your PC Connect the GSM Gateway to the PC using a standard USB miniUSB cable Start the 1258 Manager by clicking the icon 1258 Manager v1 4 by Microbit 2 0 AB 2008 2009 c papa L FEW HW version Fw update Setup Firmware version Hardware version 000 000 003 011 003 1258 attached When the GSM Gateway is connected to the Manager tool the status bar at the bottom will show 1258 attached Push Get to see the GSM Gateway Firmware and Hardware versions In this example FW 3 11 and HW 3 8 1 Firmware upgrade To upgrade the GSM Gateway Firmware select the FW update tab 1258 Manager v1 4 by Microbit 2 0 AB 2008 2009 c Firmware path 1 Select file Update 1258 attached Click on Select file Page 10 of 13 8 2 ROCOM ort Brows to find and select the new FW file supplied by Rocom GmbH or
7. your local distributor Note The FW file always has the file extension bin e g gatewayFW bin Click on Update During the update you can follow the progress in the status bar Note Be careful not to disconnect the power during FW upgrade Setup For configuration of user specific settings use the Setup tab and click on Get setup 1258 Manager v1 4 by Microbit 2 0 AB 2008 2009 c Pw HW version Fw update 1258 attached A new window will appear showing all configurable settings Li Setup Info v5 8 2 1 Serial number 10706 GSM Led 1 limit 0 31 15 GSM Led 2 limit 0 31 GSM Battery alarm text GSM Battery reset text 25 Battery fail level m 4400 Battery test time secs Gain dB GSM gt POTS 300 GSM Battery alarm nr 05 Gain dB POTS gt GSM Tone generation Country Local GSM tones Generate local GSM tones Ring back tone 440 Hz 1500 3500 ms Busy tone 440 Hz 500 500 ms Congestion tone POTS 1 power saving Off v Total cycle timefms 10 Page 11 of 13 0 v Power up timefms 10 LED control on signal strength 440 Hz 500 500 ms Dial Congestion tone battery fault Disabled Dial tone 440 Hz continously Ring signal 50 Hz 1500 3500 ms There are two LED s showing the strength of the GSM signal S1 and S2 You can set the limits when to light these LED
8. eresere 11 8 2 2 Batlery COMI sess cccscascsnascescavescossecs E E 12 82 3 Galil CONO hreet arrr tie Aas E E ieee passes ee ad 12 8 24 POTS1 power SAVING cscri siina iia a reais eee eee 12 8 25 Tone GEMeration ssc csc cc eed eiaa EEEE E EAEE 12 8 2 6 Dial tone 2 battery failure ec cceccceseesesecseesecsseeecssessessecseseeeseeseseseseseaeeaeeaes 12 9 Technical Data ses ciscscescosescesessescsscosescesessegtcutesevauscuaceets condedanedacbads conbucuscsaveads coset aveesiveds coubeassesseeees conbeaiye 13 10 COMtACE PORT ATOM esis cde cases re cck R E N A A OAA sack ences IR 13 1 Content of delivery GSM Gateway Antenna GSM Gateway Manual this document Power adapter 230VAC 12 VDC 2 PIN code Note The GSM gateway must always be switched off before inserting or removing the SIM card The SIM card does not need to have a PIN code activated If the SIM card has a PIN code activated it must be set to 1234 When inserting the SIM card the GSM Gateway will automatically change the PIN code to a random 4 digit code to prevent misusage of the GSM unit If the SIM card must be changed the new SIM card must have any of the PIN codes above or have the PIN code deactivated If the new SIM card has a PIN code activated a factory reset must be done to repeat the random procedure above Otherwise the GSM Gateway will try the random PIN code and cause the SIM card to be locked See section Back panel connectors and
9. indications for information of how to make a factory reset 3 Installation Find a suitable place where to mount the GSM gateway Make sure the GSM coverage is OK before the GSM gateway is mounted with the attached screws Make sure the LEDs on both sides are visible Gently insert the SIM card into the GSM unit as shown in the pictures below e Mount the antenna and connect the power cable The startup might take up to 30 seconds before the GSM Gateway has established the connection with the GSM network For information of how to understand the LED indications please see section 4 and section 5 below For information of how to shut the GSM Gateway off see section 0 below Page 2 of 13 ROCOM ore 4 Front panel connectors and indications e g PHONE 2gp iF USB 2 2 amp USB USB 2 0 Mini connector to be used for connection with a PC The USB can be used for updating the software of the GSM Gateway and also for adjusting parameters such as battery tripping limits LED Indicators LED Status Indicates PWR STAT 1000 ms ON 1000 ms OFF Normal status 100 ms ON 1500 ms OFF Backup power in use eS ON Off hook of the connected telephone device Flashing Ringing signal BATT Flashing Battery problem The battery is not Red LED connected or the battery has not passed a battery test See also section 6 below PHONE Connection to standard telephone
10. nside the GSM Gateway 6 Battery The battery is supervised in two different ways The first low battery voltage indication is activated when the battery voltage is too low for any reason The second is a battery fault alarm activated when the battery capacity is too low and it is time to replace the battery In case there is a battery alarm low battery voltage indication the GSM Gateway will change the dial tone see section Technical Data for information on dial tone 2 specifications The EC II Flex will detect the new dial tone and send a battery alarm to the receiver See section SMS functionality for information on how to turn the dial tone 2 off 6 1 Low battery voltage indication A low battery voltage indication is shown by a red LED see section 4 above and by a change of the normal dial tone see section 7 2 below and can be activated by any of the following reasons This check is done every 30 s The battery is not mounted The battery voltage drops below 4 4 VDC when the unit is connected to mains power The battery voltage drops below 4 2 VDC when the unit is powered by the battery If the unit is powered by the battery and the battery voltage drops below 4 0 VDC the GSM Gateway will shut off to prevent permanent damage of the battery These voltage levels are not programmable Page 4 of 13 6 2 Battery fault alarm A battery fault alarm is indicated the same way as low battery voltage indica
11. s 8 2 2 Battery control For information on the battery control please see the section 6 Battery Fill out the GSM Battery alarm nr where to receive battery alarm SMS Fill out the GSM Battery alarm text SMS text from the Gateway in case of battery alarm E g Battery alarm from lift 4435 Fill out the GSM Battery reset text SMS text from the Gateway when the battery is replaced E g Battery reset from lift 4435 8 2 3 Gain control Gain control is used to amplify or attenuate the signals between the GSM network and the analogue line from the Gateway The signal gain can be set on both GSM to POTS and POTS to GSM Please note that POTS is the analogue line generated by the GSM Gateway Setting a negative value will attenuate the signal and positive values will amplify the signal The signal gain and quality of the GSM system differs between countries and you may therefore be required to change the signal gain to adjust for these differences 8 2 4 POTS1 power saving Note Do not use this feature for any emergency alarm systems The power save will disconnect the POTS line power during a pre defined time Operating modes are Off Always on and Battery only Battery only mode will enable the function only during battery operation to increase the battery operation time After selecting operating mode set Total cycle time Cycle time for power save operation E g select cycle time to
12. ted by sending an SMS to the GSM Gateway The SMS must include the telephone number and an alarm text The SMS is not case sensitive See picture below for an example In the example below the battery alarm level is not changed Balarm On OVOSALZALS Beceainy alarm from Ihe AG Balarm On O7OS2Z12 i sel BeimeSiny alarm from S aa lt lt 4 4 SMS to GSM Gateway SMS from GSM Gateway Page 5 of 13 ROCOM ore The GSM will acknowledge a correct programming by returning a SMS as above In the example below the battery alarm level is changed to 4 0 V 4000 mV Balarm On 4 0004 OVOSAAZ sys Barrer alarm from Balarm On 4 000 OVOSA TAIS Battery alarm from Iie 452 Lift 452 l Asobi SMS to GSM Gateway SMS from GSM Gateway The GSM will acknowledge a correct programming by returning a SMS as above In this example a battery alarm will generate the following SMS from the GSM Gateway Barteee alarm from Mate 452 SMS from GSM Gateway It is possible to generate an SMS Bares when the battery is replaced to a new one after a Battery fault alarm This function is activated by sending an SMS to the GSM Gateway The SMS must include an appropriate text The SMS is not case sensitive See picture below for an example Bares SMS is always sent to the same number as Balarm Page 6 of 13 Bares On Battery TOR reom Laire 452 Batewenye OK EEO Ibs see 452 SMS to
13. tion 6 1 but can also be sent by SMS Please view SMS functionality for information on settings or how to use the USB connector and 1258 Manager software The first battery test is made after 48 hours and the following every 24 hour During a pauer test a load is connected to the battery and the battery voltage measured A battery test lasts for 5 1 minutes and if the voltage drops below 4 4 VDC during this time a battery fault alarm is activated A battery test will not be performed when the GSM Gateway is powered by the battery An active battery fault alarm is automatically reset after a passed battery test Normally the battery will last 2 4 years but this is very much depending on the surrounding temperature and how much the battery is used When the battery is failing only replace the battery with an equivalent type Other types of battery might damage the GSM Gateway A polyswitch fuse is integrated in the battery package to prevent it from damage in case of high temperatures The fuse is automatically reset when the temperature is normal again 1 5 minutes is the default setting The time is programmable via USB 1258 Manager 2 4 4 V is the default setting The levels for the battery fault alarm is programmable via USB 1258 Manager or via SMS by the distributor 7 SMS functionality 7 1 Battery alarm It is possible to generate an SMS when a battery fault alarm occurs and the functionality is activa
Download Pdf Manuals
Related Search
Related Contents
Sanyo RP-5200 User's Manual Dealing With Battery Parasitic Drains Manuale d`uso e manutenzione PS-5817V PS-5817H - Tec-Wi Manual del Usuario - Rockwell Automation SIDizer User Manual CATÁLOGO TÉCNICO - Salvador Escoda SA Comcover Learning Centre User Guide TruVision DVR 41 Quick Start Guide Copyright © All rights reserved.
Failed to retrieve file