Home
JXDH-6602B Stand Alone Scrambler User Manual
Contents
1. 777zzwoz_o__ _ ___z a Chengdu Jiexun Electronics Co Ltd Phone 028 82000090 http www jie xun com E mail jx jie xun com JXDH 6602B Stand Alone Scrambler User Manual Charter 2 Installation Guide 2 1 Acquisition check Open the device package and check the articles do check the packing material of small parts check packed goods according to packing list or below items e JXDH 6602B Stand Alone Scrambler 1 unit e User manual lcopy e Coaxial line with Q9 head for each ends 1 radix e AC input power cord 1 radix If there is any missing or mismatch of above items please contact local dealer 2 2 Installation preparation Follow below steps when installing the device The detailed installation will be described at the rest part of this chapter the rear panel sketch is for the reference of specific position Following content is the main for this chapter e Checking if there any possible missing or damage device during transport e Checking if the situation is suitable for installing e Install Stand Alone Scrambler e Connecting signal wires e Connecting communication port for option 2 2 1 Installation flowchart Connecting Acquisition Fixing Hae Connecting Setting Running Check Device Bower Signal Wire Parameter Device Cord Chengdu Jiexun Electronics Co Ltd Phone 028 82000090 http www jie xun com E mail jx jie xun com JXDH 6602B Stand Alone
2. FD 01 A8 00 To press lt D gt left right key can modify physics address set Move tabbing to the to be reset parameter location modify the parameter value with A k y up down key confirm the value with ENTER key Return to the previous menu by pressing menu key Now LCD showing Physics address Factory settings gt For the entry of Factory settings please press V down key now LCD showing Physics address Factory settings 4 prompt means Factory setting Restoring Factory default setting 12 Chengdu Jiexun Electronics Co Ltd Phone 028 82000090 http www jie xun com E mail jx jie xun com JXDH 6602B Stand Alone Scrambler User Manual For the entry of Factory settings please press Enter key to enter Restoring Factory default setting now LCD showing Factory settings Yes XNo To press lt 1 P gt gt left right key can restore factory setting Move X tabbing to the to be reset parameter location then press ENTER for confirmation Press Menu key return to previous menu now LCD showing Physics address Factory settings For the entry of About System please press V down key Now LCD showing About System prompt means About System For the entry of About system please press ENTER key now LCD showing Standard
3. Scrambler User Manual 2 2 2 Environment Requirement a geg irement ______________ When user install machines array in one machine hall the Machine hall distance between 2 row of machine frames should be 1 2 1 5m space and the distance to wall should be no less than 0 8m Electric Isolation Dust Free Machine hall Volume resistivity of ground anti static material 1x10 1x10 Q floor Grounding current limiting resistance 1 MQ Floor bearing should be greater than 450K g m Environment Under 5 40 C operate for long time under 0 45 C operate for short temperature time installing air conditioning is recommended Relative Under 20 80 operate for long time under10 90 operate for short temperature time 86 105KPa Installing rubber strip for sealing door gaps and dual level glasses for Door amp window window be covered with wallpaper or brightness less paint rather than easy Wall pulverization dope Fire protection Have Fire alarm system and extinguisher Requiring device power air conditioning power and lighting power are Power independent to each other Device power requires AC power 110V 220V 50Hz 50W Please carefully check before running 2 2 3 Grounding requirement e All function modules good grounding designs are the base of reliability and stability of device Also they are the most important guarantee of lightning arresting and interference rejection Therefore system must follow
4. operation of system adjustment and the working state display After complete of scrambler installation as per requirement Turn on the power LCD showing System initializing Then LCD SHOWING System startup please wait After the complete of startup LCD showing below Scrambler ver2 0 Now the power indicator light of front panel is on After a while of startup complete LCD will have the notice of light off version V2 0 LCD showing below normal working interface Scrambler ver2 0 Enter system adjustment menu to press menu key Enter status display menu to press gt right key 3 3 1 Entrance of system adjustment menu After the complete of standard scrambler installation as per requirement please turn on the power switch After system startup finished LCD showing the normal working interface 10 Chengdu Jiexun Electronics Co Ltd Phone 028 82000090 http www jie xun com E mail jx jie xun com JXDH 6602B Stand Alone Scrambler User Manual Scrambler ver2 0 At the normal working interface Press Menu key to enter system adjustment menu LCD showing IP address Netmask The notice of system adjustable menu prompt means IP address IP address setting X For the entry of IP address setting Press ENTER to enter IP address parameter setting Now LCD showing IP address 192 168 001 240 If IP address need to be modified
5. please move _ tabbing to the parameter location with lt q gt left right key Press V ae A UP DOWN Key to modify parameter value then confirm the value with ENTER key Press MENU key return to previous menu now LCD showing IP address Netmask For the entry of Netmask Please press y down key Now LCD showing IP address Netmask 4 prompt means netmask subnet mask setting For the entry of Netmask set please press Enter to enter Netmask parameter setting now LCD showing Netmask 255 255 255 000 If Netmask need to be modified please move tabbing to the to be reset parameter location Chengdu Jiexun Electronics Co Ltd Phone 028 82000090 http www jie xun com E mail jx jie xun com JXDH 6602B Stand Alone Scrambler User Manual with lt D gt left right key Modify parameter value with A i V up down key confirm the value with ENTER key Return to the previous menu with menu key now LCD showing IP address Netmask X For the entry of physics address please press V down key Now LCD showing Physics address Factory settings prompt means Physics address Physics address setting For the entry of Physics address please press Enter key to enter Physics address parameter setting Now LCD showing Physics address 00 FF
6. 4al ehan JXDH 6602B Stand Alone Scrambler User Manual V2 1 JXDH 6602B Stand Alone Scrambler User Manual Chapter 1 Product Outline 1 1 Outline JXDH 6602B stand alone scrambler is applied in the simultcrypt scrambling of input code stream It can send fixed or agile word scrambling according to transport stream The built in simulcrypt synchronization controller transmits the exchange information with ECMG When integrated with CA the scrambler adjusts crypto period appropriately in order to make decoder function normally This is a highly integrated equipment for digital TV scramble 1 2 Features DVB common scramble system description ETR289 common scramble system description DVB Scramble designated program or transport stream Comply with DVB standard arithmetic supports simultcrypt compatible with multi CA system Comprehensive MPEG code stream analysis Re process PSI SI information from TS Channel protection for ASI output input Bit rate auto adaption PCR reset and re mark Remote real time monitor of transport stream Auto switch and input backup pocket format auto adaption of 188 204 bit rate Network monitor PCR correction ZE Application e Program collect distribute e SDH network transport satellite DVB T MMDS e Digital CATV Front head end e Video on demand VOD e Digital swerve e Video distribution for television network Chengdu Jiexun Electronics Co Ltd Phon
7. Scrambler Ver2 0 Return to previous menu by pressing menu key now LCD showing About System Return to the normal working interface please re press menu key now LCD showing Scrambler ver2 0 3 3 2 Entrance of the working state displaying menu At normal working interface press P gt right key to enter state displaying in turn 13 Chengdu Jiexun Electronics Co Ltd Phone 028 82000090 http www jie xun com E mail jx jie xun com JXDH 6602B Stand Alone Scrambler User Manual At normal working interface press gt right key once to enter ASI 1 ASI effective rate of 2 input channels displaying LCD showing ASI 1 Rate 50 00 Mbps ASI 2 Rate 50 00 Mbps Above indicates the size of 2 input channel effective rates ASI 1 ASI 2 X At normal working interface please press gt gt right twice to enter scrambling channel 1 CA working state displaying LCD showing Encrypt CH 1 Ecm OK Emm OK Normal working state indication of both Ecm and Emm As shown in photo on the right Encrypt CH 1 N L Scrambling channel is not opened Or Pe pene Need to be opened by operation network management software Encrypt CH 1 As shown in photo on the right Abnormal working state of scrambling Please check the set of network management software and physical connection path X At normal working state please press gt gt left 3 times to en
8. e 028 82000090 http www jie xun com E mail jx jie xun com JXDH 6602B Stand Alone Scrambler User Manual e Program encrypt e Transport stream disposal 1 3 Technical Parameter Ethernet 0 45 C Operating 20 80 C storage Power supply 110V 220VAC 10 50 60Hz 25W Miscellaneous Temperature 1 4 Principle Frame Ethernet interface odule Control module 1 5 Appearance and description TS output TS output Front panel illustration JXDH 6602BStandA loneScrambler pig Power O A Enter Menu Lock Video diehan i O lt gt rm C rm Broadcasting BIE BM i y i Li J Cheng Du Jiexun Electronics Co LTD WATERWET A RAT j BR 7 i i 2 g 8 9 1011 Chengdu Jiexun Electronics Co Ltd Phone 028 82000090 http www jie xun com E mail jx jie xun com JXDH 6602B Stand Alone Scrambler User Manual 1 LCD Screen display 2 Power indicator red 3 Signal lock indicator 4 CA1 indicator 5 CA2 indicator 6 CA3 indicator 7 CA4 indicator 8 Up down left right button 9 Confirm button 10 Menu button Back panel illustration AC110V 220 50 60Hz BGAN Ethernet 1 ASI rate stream dual Same output interface 2 Dual alone rate input interface ASI 1 ASI 2 3 RS232 interface 4 Equipment net management Ethernet interface RJ45 5 Power switch Fuse socket Power socket 6 Ground Column __
9. exun Electronics Co Ltd Phone 028 82000090 http www jie xun com E mail jx jie xun com JXDH 6602B Stand Alone Scrambler User Manual Adjustment of system submenu IP address IP address IP Hiki Ss 192 168 001 240 System adjustment menu Netmask Netmask TARBE 255 255 255 000 Physics address Physics address Vj HE Hb Sit isc E 00 FF FD 01 A8 00 Factory Settings Factory Settings ks KH i Yes No State displaying submenu About System Standard Scrambler KF 52 0 Ver2 0 Input channels effective ASI 1 Rate 50 OOMbps ASI 1 Rate 00 00Mbps ASI 1 Rate 00 00Mbps displaying ASI 2 Rate 50 OOMbps ASI 2 Rate 00 00Mbps ASI 2 Rate 00 00Mbps Status dicalavi ora d k Encrypt CH 1 Encrypt CH 1 Encrypt CH 1 Ecm OK Emm OK Not be opened menu displaying CA2 Encrypt Encrypt CH 2 working Ecm OK Not be opened state displaying CA2 working Encrypt Encrypt CH 3 Ecm OK Not be opened state displaying Encrypt CH 4 Encrypt CH 4 CA2 Ecm OK Emm OK Not be opened working state j j Displaying of normal Notice Scrambling channel A displaying j Displaying of abnormal working state is not opened need to be f working state Please opened by network check network management software management path Chengdu Jiexun Electronics Co Ltd Phone 028 82000090 http www jie xun com E mail jx jie xun com JXDH 6602B Stand Alone Scrambler User Manual 3 3 The
10. gdu Jiexun Electronics Co Ltd Phone 028 82000090 http www jie xun com E mail jx jie xun com JXDH 6602B Stand Alone Scrambler User Manual Chapter3 Operation The front panel of scramler is user s interface Before normal operation User can use factory default setting reset system parameters or check equipment working state display The modifications of system parameters includes IP address set subnet mask address physics address restoring factory default etc Equipment working state display includes the input channel effective rates shows scrambling channel 1 4CA working state display User can use the factory default parameters or execute the scrambling operation through the software of net management Display interface provide users with perfect menus below is panel operation introduction 3 1 The keyboard function introduction of the front panel Up Down key Modify the activation parameters and page up down Left Right Key Enter the working state parameters displaying Then press up down left or right to choose the to be reset parameter ENTER Key Activate the select of adjustment menu and save the corrected parameters MENU Key enter exit MENU 3 2 JXDH 6602B scrambler menu JXDH 6602B scrambler main menu is divided into the system adjustment menu and the displaying menu of equipment working status Scrambler main menu f System adjustment Scrambler main menu Working state displaying Chengdu Ji
11. ower supply outlet while insert the other end to AC power e Connecting Grounding Wire When the device solely connects to protective ground it should adopt independent way say share the same ground with other devices When the device adopts united way the grounding resistance should be smaller than 10 Caution Before connecting power cord to Encoder user should set the power switch to OFF Chengdu Jiexun Electronics Co Ltd Phone 028 82000090 http www jie xun com E mail jx jie xun com JXDH 6602B Stand Alone Scrambler User Manual 2 4 Signal Wire Connection The signal connections include the connection of input signal wire and the output signal wire The signal connection wires are both ASI 2 4 1 ASI input connection User can find ASI INI IN8 input port on the Equipment according to connector mark described in the rear panel illustration and then connecting the Q9 coaxial cable one end to the ASI IN1 8 and the other end to the Encoder s or other equipment ASI output port 2 4 2 ASI Output Port Connection User can find ASI output port on the Equipment according to connector mark described in the rear panel illustration and then connecting the ASI cable in the accessories one end to the JXDH 6102 multiplexer s ASI output port and the other end to the scrambler s or Modulator s input port multiplexer s ASI output port and its connected ASI cable connector illustrated as follow Chen
12. ter scrambling channel 2 CA working state displaying LCD showing Encrypt CH 2 Normal working indication of both Ecm and Emm Ecm OK Emm OK As shown photo on the right Encrypt CH 2 Not be opened Scrambling channel is not opened need to be opened by operation network management software As shown photo on the right Encrypt CH 2 Abnormal working state of scrambling Please check the set of network management software And Physical connection path 14 Chengdu Jiexun Electronics Co Ltd Phone 028 82000090 http www jie xun com E mail jx jie xun com JXDH 6602B Stand Alone Scrambler User Manual X At normal working interface Please press b gt right 4 times to enter scrambling channel 3 CA working state displaying LCD showing Encrypt CH The normal working indication of both Ecm and Emm Ecm OK Emm OK As shown photo on the right Encrypt CH 3 N Vl Scrambling channel is not opened Oppa opens Need to be opened by operation network management software As shown photo on the right Abnormal working state of scrambling DR geYB Ol Please check the set of network management software And Physical connection path X At normal working state please press gt right 5 times to enter scrambling channel 4 CA working state display LCD showing The normal working indication of both Ecm and Emm Encrypt CH 4 Ecm OK Emm OK As shown photo on the right Encr
13. this rule e Coaxial cable s outer conductor and isolation layer should keep sound electric conducting with the metal housing of device e Grounding conductor must adopt copper conductor in order to reduce high frequency impedance and the grounding wire must be as thick and short as 5 Chengdu Jiexun Electronics Co Ltd Phone 028 82000090 http www jie xun com E mail jx jie xun com JXDH 6602B Stand Alone Scrambler User Manual possible e The 2 terminals of grounding wire must make sure for well electric conducting and process for antirust e It is prohibited that users use other devices as part of grounding wire s electric circuit e The section of the conjunction between grounding wire and device s frame should be equal or greater than 25 mm2 2 2 4 Frame Grounding All the machine frames should connect to protective copper strip The grounding wire should be as short as possible and avoid circling The section of the conjunction between grounding wire and grounding strip should be equal or greater than 25mm 2 2 5 Device Grounding Connecting the device s grounding rod to frame s grounding strip with copper wire 2 3 Wire s Connection The power supply outlet is located at the left of rear panel and the power switch is just above it The protective grounding wire connective screw is located at the down left side of power supply outlet e Connecting Power Cord User can insert one end into p
14. to the chassis power must be off immediately 6 Please put the encoder in a horizontal place and avoid pressing 7 Please do not pile heavy objects on this equipment to avoid crush the equipment 8 This equipment should be placed with ventilation and suitable temperature to avoid the fierce light moisture and severe vibration 9 When the machine is moved to a new place with sharp different temperature please keep it off for one or two hours 16 Chengdu Jiexun Electronics Co Ltd Phone 028 82000090 http www jie xun com E mail jx jie xun com
15. ypt CH 4 Scrambling channel is not opened Not be opened Need to be opened by operation network management software As shown photo on the right Abnormal working state of scrambling Please check the set of network management software ZOH And Physical connection path In the course of this operation please press lt 1 left to return previous interface press D gt right 6 times to return to normal working state interface LCD showing below Scrambler ver2 0 15 Chengdu Jiexun Electronics Co Ltd Phone 028 82000090 http www jie xun com E mail jx jie xun com JXDH 6602B Stand Alone Scrambler User Manual 3 3 3 Indicator light description of panel POWER Power indicator light is on while power is working normally Lock 1 Lock 2 Input signal lock indicator light indicator light on when input signal select is normal CA1 CA2 CA3 CA4 Each scrambled channel status indicator light Light is on when CA is normal 3 3 4 The musts of safety 1 Please read this introduction carefully before use the equipment Initial use please ensure that the video source connected normal Do not open the lid to avoid electrical shock or damage the unit ER ad a When the machine is not used in a long time please unplug the power cord Please do not use a damaged power lines to prevent fire or electric shock 5 Do not touch power line with wet hands When a liquid flows in
Download Pdf Manuals