Home
AVRed-ES100
Contents
1. Each connection must be Safety Extra Low Voltage kind SELV and must stay inside buildings Fl Laite on liitett v suojamaadoituskoskettimilla varustettuun pistorasiaan NO Apparatet m tilkoples jordet stikkontakt SE Apparaten skall anslutas till jordat uttag AVRed ES100 User s Manual AuviTran 2008 6 10 TECHNICAL SPECIFICATIONS 483 x 253 x 44mm 19 rack 1U Height lt 50 Watts P TRTE 100 240VAC 50 60Hz 1 5A Max 5Vdc 5A max 12Vdc 2A max Sree 100 240V 47 63Hz 1 35A 5Vdc 5A 12Vdc 2A 5 C to 70 C Max 95 non condensing 5 C to 40 C 5 to 90 non condensing Network and links Rx and Tx Activities Active link running Quality Status of both Links A and B In or Out Mode selected for device Power Main Aux and On Display 2 Neutrik OpticalCon for FoNeutrik version 1 IEC Power inlet 4 Neutrik EtherCon RJ 45 1x6 poles Euroblock Connector for Aux power supply 2 BNC for word clock synch in and out 1 DB9 connector for Serial Port 4 Dip Switches for hardware configuration Optical Fiber 62 5 125 Multimode fiber used with LC connectors or Neutrik Opticalcon Mode IN EtherS ound Input to 2 resilient links Mode OUT on AVRed ES 2 resilient links coming from an AVRed ES module to one Eer ound Output P ort Mode OUT on Switch 2 resilient links coming from an Ethernet Switch to one Eier ound Output Port IN or OUT port depending of operating mode selected
2. 6 COPYRIGHT The information in this manual is protected by copyright Therefore reproduction distribution of whole or part of this manual is strictly forbidden without the prior written agreement of AuviTran 7 AUVITRAN WEBSITE MORE INFORMATION Please visit our website for any question of further inquiry concerning our product range Updates will also be posted when available http www auvitran com 8 PACKAGE CONTAINS e 1AVRed ES100 Cord set with proper plug configuration must be used depending on country in which the product is used AVRed ES100 User s Manual AuviTran 2008 5 9 PRECAUTIONS A A A des A i Eb gt gt Do not modify open or disassemble the Product The guarantee shall be null and void in that case Do not apply excessive pressure on connectors or any other part of the board Do not touch the metallic sharp parts pins of the product This product is designed to be rack mounted Be sure to observe following installation rules of this kind of equipment Elevated Operating Ambient If installed in a closed or multi unit rack assembly the operating ambient temperature of the rack environment may be greater than room ambient Therefore consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature Tma specified by the manufacturer Reduced Air Flow Installation of the equipment in a rack should be such that t
3. be selected Note Option must be set on both side of redundant link i e selected on both AVRed ES100 control page 15 4 4 Status box The Status box shows temperature in the box fan speed and its turn off switch and the front panel brightness setting Status Temp 43 3 C Fan Speed 174 Stop Fan Brightness d Fan speed is automatic depending on box temperature Thresholds were optimized regarding fan noise and maximum working temperature For noise critical environment fan can be turn off Please note that if internal temperature becomes too high AVRed ES100 will override the Stop Fan command to ensure proper cooling of the box AVRed ES100 User s Manual AuviTran 2008 17 15 4 5 Bi directional Status box Er Directional Status Ss Bi Directionnal mode OM Loopback If AVRed ES100 is inside a bi directional ES network this box will display the Bi Directional mode ON message You can also force the device to be end of bi directional loop thanks to Loopback checkbox 15 4 6 Mode box If you own an AVRed ES100 FoNeutrik this box shows you if redundant links are routed on the back panel EtherCon RJ45 connectors or on the front panel OpticalCon optical connectors It is a read only display as you must use back panel Dip Switches to change mode Mode Ce EtherCon OpticalCon 15 4 7 Clock Setting box This control box enables you to choose the clock source of your network in case
4. your AVRed ES100 is the Primary Master Clock Setting Ow Clock EtherS ound 15 4 8 Serial Communication Mode box This box helps you to create a Unicast serial tunneling between AVRed ES100 serial port and a remote device All you have to do is to check the Unicast button and choose the destination device of the communication to create the tunnel Serial Communication Mode If you leave the Slave button checked that means that AVRed ES100 is able to communicate with a remote device that was configured to communicate with 15 4 9 Serial Port Configuration box Serial Port Configuration Baud Haie 38400 w Parity Bits per Char Parity Stop Bits Handshake This box will helps you to configure properly the physical serial port parameters as baud rate parity etc AVRed ES100 User s Manual AuviTran 2008 18 16 Auxiliary power supply AVRed ES100 provides another source of power supply to improve the reliability of the system It allows you to have two distinct power supply sources for redundancy solutions When both power supply units PSU are plugged AVRed ES100 monitors them and always chooses best In case of failure of one PSU or associated electrical network AVRed ES100 will so continue to work Auxiliary PSU ref AVPSAUX E45 EB is validated and provided by AuviTran only Please contact us if you want to integrate the redundant PSU in your system http www auvitran com AVRed ES100
5. 3rd port for PC remote control A and B with automatic selection of best link 2 8us in AVRed ES100 AVRed ES100 Mode Approx 22us in Switch AVRed ES 100 Mode 4 samples 83us at 48 kHz RS232 serial port 48 kHz local clock when Primary Master or EtherS ound Network When not PM Word clock In used for synchronization O Network Monitoring of Temperature inside the Box Network Monitoring of PSU Failure for Main and Aux power supply Automatically Controlled by internal Temperature Off Windows XP ES Monitor enables to remotely set control and monitor an EtherS ound network and provides enhanced property pages to manage the AVRed ES100 specific parameters Links status Power supply status Main Aux Temperature monitoring Fan remote control and PSU Aux Main remote control AVRed ES100 User s Manual AuviTran 2008 7 11 Rear Panel Description AuviTran AVRed ES100 AC IN Main lg mo Power switch switch on or off the main power supply AC IN main power supply Refer to tech specs for AC range DC IN auxiliary power supply for redundancy purpose Dip switches setup the device Serial Port standard RS232 for custom application Word Clock Input and Output for external synchronization EtherSound Ports link to EtherSound network or control PC Redundant Links double Cat 5 redundant links Here is the detailed description of the dip switches Every setup will be explained bel
6. FCC to use the product 2 IMPORTANT When connecting this product to accessories and or another product use only high quality shielded cables Cable s supplied with this product MUST be used Follow all installation instructions Failure to follow instructions could void your FCC authorization to use this product in the USA 3 NOTE This product has been tested and found to comply with the limits for a Class B Digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential environment This equipment generates uses and can radiate radio frequency energy and if not installed and used according to the instructions found in the users manual may cause interference harmful to the operation of other radio communications Compliance with FCC regulations does not guarantee that interference will not occur in all installations If this product is found to be the source of interference which can be determined by turning the unit OFF and ON please try to eliminate the problems by using one of the following measures Relocate either this product or the device that is being affected by the interference Utilize power outlets that are on different branch circuit breaker or fuse circuits or install AC line filter s In the case of radio or TV interference relocate reorient the antenna If the antenna lead in is 300 ohm ribbon lead change the lea
7. If a non ES100 device is within the daisy chain 3 port enables remote PC control of the local device only if not primary master AVRed ES100 User s Manual AuviTran 2008 13 15 AVRed ES100 IN ESMONI TOR SOFTWARE 15 1 Software Installation Please visit our website to download the latest version of our EtherSound Monitor Software called ESMonitor http www auvitran com view php products_AVS ESMonitor php and save the file on your hard disk ESMonitor requires Windows XP to function You are now ready for installation Refer to the ESMonitor documentation for installation When ESMonitor is installed on your PC you can run ESMonitor and manage any AVMRed ES100 devices connected to an EtherSound network Refer to ESMonitor documentation for generic EtherSound device management such as Enumeration of EtherSound devices 15 2 Getting Started with AVRed ES100 and ESMonitor Software The computer on which the EtherSound Monitor is installed should now be connected to the primary master of the EtherSound network The primary master must be the first EtherSound based device of the network After running the ESMonitor Select an AVRed ES100 device on the device list or tree list 15 3 AVRed ES100 Properties Page in ESMonitor When selecting the properties page ESMonitor will display the following information e ES Monitor by AuviTran File Edit Command Help Bod Es fk G o BEBOREGEO a Properties gui NetPatch q Ethersou
8. User s Manual AuviTran 2008 19
9. Version 1 0 July 2008 O f AuviTran REID ae 2 AVRed ES100 USER S MANUAL MM wm SCH gt AVRed ES100 B In 0ut 3rd Aux Ether A viran A EE 13S S 9 lt M DNA pr Status gd Link Activity Mode Pawer EtherSound Redundant Links L On le Ka W k ama o AVRed ES100 b a e A B In Out 3rd Aux AuviTran ANG es a ee Tx a Our On el 2 lt M S Ba Status y Link Activity Mode _ Power EtherSound Redundant Links e D VU AVRed ES100 User s Manual AuviTran 2008 1 2 ELECTRICAL AND ELECTRONIC INTERFERENCES RISKG 005 3 3 LIMITATION a Vs 3 AA e tube tuks Vals mea 4 A A Ao O o O 5 ll TP SSA 5 7 AUVITRAN WEBSITE MORE INFORMATION s sss sss sss ss css sse s eee ennenen 2 D He Zeit 5 9 PRECAUTIONS s sss ss sssssseee eenn nenen D 10 TECHNICAL SPEGCIFIGATION Sion 7 11 REAR PANEL DESCRIPTION ss ss sss cesses neee eenn ennenen ennenen 8 12 ARCHITECTURE USING AVRED ES 100 cooncoccconcconcconccncconnconcconcconnnnnrnnnronnnnans 9 13 AVRED ES100 MODES o ocoocconconcconconccnncnncnnncnncnnncancnnrnanrnnrnnnnancnnrnanranrnnrnanenannn 10 13 1 Dip switches Mode Setting uk xeeekEK KEE RK KREE KNKKKKEK KEE RR KKK KKK EEKKEK KR R EN 10 2 Copper BOptical Setting cccccocococooooooooooooocoo nn nnnnnnnnnnnnana 10 13 3 COMME CUR SCNOMAUCS iii 11 dl RE AVRed mode ENNEN EEN 11 13 3 2 Switch AVRed mode 11 13 4 Why
10. d in to co axial type cable If these corrective measures do not produce satisfactory results please contact the local retailer authorized to distribute this type of product If you cannot locate the appropriate retailer please contact Yamaha Commercial Audio Systems Inc Electronic Service Division 6600 Orangethorpe Ave Buena Park CA90620 The above statements apply ONLY to those products distributed by Yamaha Commercial Audio Systems Inc or its subsidiaries COMPLI ANCE INFORMATION STATEMENT DECLARATION OF CONFORMITY PROCEDURE Responsible Party Yamaha Commercial Audio Systems Inc Address 6600 Orangethorpe Ave Buena Park Calif 90620 Telephone 714 522 9011 Type of Equipment EtherSound Redundant links Model Name AVRed ES100 This device complies with Part 15 of the FCC Rules Operation is subject to the following conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation See user manual instructions if interference to radio reception is Suspected AVRed ES100 User s Manual AuviTran 2008 4 5 TRADEMARKS All trademarks listed in this manual are the exclusive property of their respective owners They are respected as is by AuviTran Any use of these trademarks must receive prior approval of their respective owners For any question please contact the trademark s owner directly
11. h links the system is able to use one cable for upstream and the other for downstream provided this gives better results This feature is not available on Switch AVRed ES100 Mode Last but not the least the AVRed ES100 AVRed ES100 Mode proves better results by ten times superior in terms of latency for the redundant link than the Switch AVRed ES100 Mode 14 Third Port and Remote Control AVRed ES100 was built with the latest EtherSound ES100 technology and includes a 3 port for remote control and monitoring With previous version of EtherSound the control PC should always be connected to the IN port of the first EtherSound device in the network Le the primary master Now thanks to EtherSound ES100 and native AVRed ES100 3 port you can plug your control PC directly to your device even if it is not primary master 14 1 Example of architecture using 3 port Mixing control amp Remote monitoring AuviTran AVRed ES100 Serial Port OUT GG o AC IN Main Ge a Q ae SE a SS S IN Setting In Out 3rd e To From another AVRed ES100 AVRed ES100 User s Manual AuviTran 2008 12 14 2 Limitations of architectures AN Remote control via 3 port of your ES100 device is subject to few limitations when in heterogeneous EtherSound network i e ES100 and non ES100 devices Please read carefully following points a The primary master of the network should always be an ES100 EtherSound device
12. he amount of air flow required for safe operation of the equipment is not compromised Mechanical Loading Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on over current protection and supply wiring Appropriate consideration of equipment nameplate ratings should be used when addressing this concern Reliable Earthing Reliable earthing of rack mounted equipment should be maintained Particular attention should be given to supply connections other than direct connections to the branch circuit e g use of power strips This product is electrostatic sensitive make sure you check this before touching or using It The disconnect devices of the unit are the appliance inlet of the auxiliary power Supply and the appliance inlet on the rear side of the unit These must be easily reachable Conformity of this product is subject to proper electrical wiring regarding CEl364 NFC15 100 Installation must be equipped with differential protection To prevent electric shock do not remove the cover No user serviceable parts inside This unit contains hazardous voltages and should only be opened by a trained and qualified technician Both power supply sources must be disconnected before servicing
13. nd Networks E List ih Tree ts Group be Control a MS avvi6 s100 S AVRedES100 H E AVRed ES100 2 HE AVM500 ES 4 ES AYM500 ES 8 ES AYM500 ES C ES AVMS00 ES D ES AVMS500 ES E Information MAC Address 00 0E 55 03 04 28 Name AVRedES100 1 EtherSound module properties Manufacturer AuviTran Y Product family AVRED ES AVRed ES100 Firmware version Kernel version 3 07 Hardware Configuration Flag OFF Audio setup Sample Rate Single 44 1 48k Double 88 2 96k Quad 176 4 192k EtherSound inputs Channel inputs 0 EtherSound outputs Channel outputs 0 Group setup ID AVRed ES100 1 AVRed ES100 User s Manual Type AVRed ES100 Service 3 3 5 Monitor v3 3 3 AuviTran 2008 14 15 4 AVRed ES100 Control Page in ESMonitor If the Control page is selected ESMonitor will display following information ao AVRed ES100 a A B InODut 3rd Aux H m a pn a In a aue Tx Y a J Our Y On Status Link Activity Mode Power EtherSound Redundant Links Link Status Remember to activate priority link mangement on linked Aw Red Bi Directional Status KE Bi Directionnal mode UN Loopback Status Temp 39 5 C Fan Speed 0 4 Stop Fan Brightness _ e A Mode Clock Setting Gei EtherCon OpticalCon Cow Clock Co EtherS ound benal Communication Mode Serial Port Configuration Baud Rate 29000 Parity Bit
14. no case and in no way the provider of this Product AuviTran the distributor or reseller or any other party acting as provider shall be liable and sued to court for damage either direct or indirect caused by and to the user of the board and which would result from an improper installation or misuse of the Product Misuse and improper installation mean installation and use not corresponding to the instructions of this manual Please note that graphics given in this manual drawings and schemes are only examples and shall not be taken for a real vision of your own equipment configuration AuviTran is constantly working on the improvement of the products For that purpose the products functionalities are bound to change and be upgraded without notice Please read carefully the User s manual as the new functionalities will be described therein AVRed ES100 User s Manual AuviTran 2008 3 4 FCC This device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation FCC INFORMATION U S A 1 IMPORTANT NOTICE DO NOT MODIFY THIS UNIT This product when installed as indicated in the instructions contained in this manual meets FCC requirements Modifications not expressly approved by Yamaha may void your authority granted by the
15. ow ON OFF d In w AVRed Switch Copper Optical Mode FoNeutrik only AVRed ES100 User s Manual AuviTran 2008 8 12 Architecture using AVRed ES100 L Mixing control amp Remote monitoring S AF o am AVRed ES100 Au ran A So mp eee e se o F494 z A E EtherSound Redundant Links AugiTran A OG N Ethernet Switch 100Megabit Third party ES products A pair of AVRed ES100 boxes will build a redundant link composed of 2 Cat 5 cables or fibres for AVRed ES100 FoNeutrik If one link breaks down AVRed ES100 will quickly Switch on the second one Status of both links is displayed on ESMonitor software and on front panel AVRed ES100 User s Manual AuviTran 2008 9 13 AVRed ES100 Modes AVRed ES100 is able to work in 3 different modes that are set up with dip switches on the rear panel of the box 13 1 Dip switches Mode setting Dip Switches AWRed ES5100 Mode ESMonitor Position Mode Out Switch AWRed Mode Cut k UY T AVRed AVRed a mii 13 2 Copper Optical setting Dip Switches AWRed ES100 FoNeutrik Mode ESMonitor im Optical Fiber Mode baas front panel OpticalCon Mode In AVRed AVRed C7 EtherCon Gei OpticalCon Copper Mode Mode back panel RJ45 EtherCon O OpticalCon If you own an AVRed ES100 FoNeutrik you can choose if you want to use optical fiber connectors or switch back to regular copper RJ45 connectors This set
16. s per Char Parity Stop Bits Handshake Off Ke All standard parameters of the AVRed ES100 can be seen or changed in this control page You can now start the configuration of your network and enjoy the functionalities of AuviTran AVRed ES100 AVRed ES100 User s Manual AuviTran 2008 15 15 4 1 AVRed ES100 Mode The scheme below shows the current mode of your the AVRed ES100 1 Mode Output from Switch 2 Mode Output from AVRed ES100 3 Mode Input 15 4 2 Links Status box Link Status Remember to activate priority link mangement on linked 44 Red The link status is shown with colours Green for a good link Orange for a link with errors Red for a broken link X AVRed ES100 User s Manual AuviTran 2008 16 The active link is in Bold The front panel on box and in ESMonitor shows the active link 1 and the error memory 2 As errors are sometimes too fast to be seen on Leds or because you were away when the error occurred Error memory is blinking during 20s 2 sonn gt AVRed ES100 a A B InDut 3rd Aux Ax y 4 In U 1 Man Tx Y Y j Our n A Status Mode Power Erheraound Redundant Links 15 4 3 Links Options Swap Link Swap link button allows user to swap active link if possible Priority Link When available on device priority link management allows device to automatically select first link To activate priority link management button must
17. stem that will switch on the best cable in less than 100us and 3 2us pass thru latency The AVRed ES100 boxes offer full network and or local control of all parameters as well as constant network status monitoring making it ideal for live professional audio applications Build in serial port allows you to build serial tunneling communications thanks to native ES100 kernel Also word clock input and output are available for external audio synchronization over the network Auxiliary power supply connector ensures extra redundancy of your system You will find herewith the necessary instructions to use your product Please read them carefully as misuse of this device might cause serious damage to you and your environment 2 ELECTRICAL AND ELECTRONIC INTERFERENCES RISKS This Product uses high frequency digital circuits that might interfere with electrical or electronic devices placed in your working environment Please make sure this kind of device television radio device cell phones is removed in order to ensure a proper functioning of each device Always use shielded cables and connectors serial port word clock and EtherSound ports In the other case AuviTran will not guarantee the proper behavior of the product A Serial port cable must be length lt 1m to ensure proper EMC and interferences behavior A Word clock cable must be length lt 1m to ensure proper EMC and interferences behavior 3 LIMITATION OF LI ABILITY In
18. ting is useless if you own a standard AVRed ES100 AVRed ES100 User s Manual AuviTran 2008 10 13 3 Connection schematics 13 3 1 AVRed AVRed mode 4 AuviTran AVRed ES100 Serial Port 3 d AC IN Main E DS Olt Re AuviTran AVRed ES100 AC IN Main GE 13 3 2 Switch AVRed mode Ether Sound m L 20 4 0 8 16 3 2 64 12 8 25 50 o E MTR OOOOODODOO O nS ESU 205 Sab O O O O O Couse 30 zu O O O O O aoon Se sae O O O O O Dux SEE O O O O O Lix acr 10 PORT PORT 2 4 Pol 5 2 3 2 5 Po SPAT AuviTran AVRed ES100 Serial Port e AC IN Main e E heich q E amp 1 E MED a E Power Si ATA WA SC AVRed ES100 User s Manual AuviTran 2008 11 13 4 Why using AVRed ES100 in Pair instead of with a switch When using a combo of 2 AVRed ES100 Boxes instead of switch AVRed ES100 computation of link status is more precise and allows more accurate switch between links The Switch AVRed ES100 Mode combo will only detect cable disconnection while AVRed ES100 AVRed ES100 Mode will detect cable failure including quality status The AVRed ES100 AVRed ES100 mode allows system to precisely analyse status of each pair of cables Therefore system can choose the best pair for both upstream and downstream signals Consequently if errors occur on bot
19. using AVRed ES100 in Pair instead of with a switch 12 14 THIRD PORT AND REMOTE CONTROL sese ss sss sse sees neee 12 14 1 Example of architecture using 3 port sss scs s sees enea nnan n 12 14 2 Limitations Of architectures sss sese sees sss sss sese essen senses eanne nnan ennes 13 15 AVRED ES100 IN ESMONITOR SOFTWARE sss sss ss css css ees eenn eee 14 15 1 Software INSTallatiON iii da 14 15 2 Getting Started with AVRed ES100 and ESMonitor Software 14 15 3 AVRed ES100 Properties Page in ESNMonitoOr ssss sss sss sss K sss s sss essa sne 14 15 4 AVRed ES100 Control Page in ESMONItOF ee 15 15 4 DwAWRed ES100 Mode 16 E Er AM aerate o oo o O RA 16 14S LOKS ODON wy veces rr ope 17 Ole ee ee o eee 17 15 4 5 Bi directional Status box 18 Moe AS E er en ee er ee oe 18 15 4 7 Clock Setting box 18 15 4 8 Serial Communication Mode Dos 18 15 4 9 Serial Port Configuration Dos 18 16 AUXILIARY POWER SUPPLY E 19 AVRed ES100 User s Manual AuviTran 2008 2 1 WELCOME Thank you for purchasing AuviTran s AVRed ES100 We hope you will enjoy using it This product will helps you building secure redundant EtherSound networks AVRed ES100 guarantees that your digital EtherSound connection is secured by a second path In case of cable failure or even only data errors the AVRed ES100 boxes will automatically switch on the best cable AVRed ES100 is currently the fastest ever built redundancy sy
Download Pdf Manuals
Related Search
AVRed ES100
Related Contents
S-0808 catalog Philips AZ1330D Docking Entertainment System La nuova Golf Sportsvan Manual User Manual: DiskOnChip Software Utilities for TrueFFS 6.x Samsung Secadora 24 kg DV24F9A8GVP Carga frontal Manual de Usuario user manual - Victron Energy VOLTCRAFT® - Sos electronic s. r. o. 50060753_KUL.K.3010 TOSHIBA SD-151E-S Liquid Handling · Easy Handling! Gebrauchsanleitung Copyright © All rights reserved.
Failed to retrieve file