1. is a therapeutic technique mainly used for analgesic purposes to counter the effects usually pain of a wide variety of medical conditions For this purpose it finds application in treating everyday ailments troubling mankind neck pain arthrosis myalgia neuritis back pain periarthritis heaviness in legs muscle weakness just to mention a few On an academic level TENS can be divided into various categories according to the mechanism used to reduce the pain The main types are conventional TENS or fast analgesic electro acupuncture training TENS or delayed analgesic TENS at maximum values with antidromic action and consequently an immediate local anaesthetic effect The rehabilitative action of TENS is represented by its power to reduce pain thereby restoring physiological conditions more often than not this allows the patient to regain normal motor function Consider a patient suffering from irritating periarthritis they either resort to using analgesics or learn to live with the pain that often makes even the simplest movements impossible Immobility reduces metabolic activity making it impossible to eliminate algogenic substances So a vicious circle begins In addition to relieving pain TENS causes induced muscle stimulation increasing metabolic activity and blood flow and improving tissue oxygenation with an intake of nutritional substances So the positive effect can be amplified by combining TENS with muscle stimulation of the
2. Atmospheric pressure from 700 hPa to 1060 hPa Cleaning only clean the device using a dry cloth We recommend that the device be subjected to a functional test carried out by the manufacturer every 24 months The manufacturer retains that the T ONE device cannot be repaired by personnel external to its own company Any work of this nature carried out by personnel not authorised by the manufacturer will be classed as tampering with the device freeing the manufacturer from responsibility for the warranty and hazards that the operator or user may be exposed to N B disconnect the cables before placing the electronic stimulator in the bag If not the cables will bend excessively close to the connectors This may damage the cables 8 Resolution of problems and questions Any type of work on T ONE must be carried out exclusively by the manufacturer or by an authorised dealer In any event any presumed malfunction of T ONE must be verified before sending the device to the manufacturer Here below are some typical situations T ONE cannot be turned on e Ensure of presence of batteries in the unit e Recharge the batteries and try to switch it on again e Check that the ON OFF button has been pressed correctly held down for at least one second e Check that batteries have correct polarity of the batteries T ONE does not transmit electric impulses e Check that the cable jacks have been inserted in the electrodes and that the p
3. 15 minutes Stimulation intensity medium low 15 25mA increased during the last 5 minutes Position of electrodes see photos 01 to 20 in the manual of positions in relation to the area that you wish to stimulate F10 Agonist Antagonist The electronic stimulator produces contractions alternated between 4 channels during the first phase of warm up the 4 channels work simultaneously during the second work phase 20 minutes muscle contractions are alternated between Channel 1 and 2 agonist muscles and Channel 3 and 4 antagonist muscles The program is designed to restore muscle tone to the quadriceps and its antagonist the leg biceps or the biceps brachii and the triceps The work aims at developing strength With this program muscle relaxation is obtained by simultaneous stimulation from 4 channels during the last 10 minutes Stimulation intensity during the contraction enough to produce good muscle contraction voluntary contraction to reduce the sense of discomfort and reach higher intensities Intensity must be increased gradually treatment by treatment without overstraining the muscles In the event of muscle ache after stimulation use the FO9 Recovery program F10 Agonist Antagonist Program duration 33 minutes EA KA Biceps Ch1 CH2 photo 02 Triceps Ch3 CH4 photo 03 Extensors CH1 CH2 photo 11 Flexors CH3 CH4 bi q Quadriceps CH1 CH2 photo 11 Biceps femoris Ch3 CH4 Phase 1 Ph
4. epileptics pregnant women people with a high temperature anxious people or people suffering from heart disease phlebitis thrombophlebitis or serious illnesses In the event of injury muscle stress or any other health problem use the device only under medical supervision The ionophoresis program uses monophasic impulse so it is polarizing do not use near metallic prosthesis under skin minimum 10 cm from metallic prosthesis Side effects No significant side effects are known of Some particularly sensitive people have reported skin redness in the area where the electrodes were positioned the redness usually disappears a few minutes after the end of the treatment Should the redness persist please consult a doctor In rare cases stimulation carried out in the evening can cause some people to experience difficulty in falling asleep If this occurs suspend the treatment and consult a doctor Pag 4 USER MANUAL T ONE Medi Medi Pro cod doc MNPG06 03 j C MEDICAL DIVISION 3 Warnings T ONE has been designed and manufactured to be operated with 4 rechargeable AA batteries e The device must not be used in the presence of patient monitoring equipment e Do not use T ONE with electrosurgical or shortwave or microwave therapy equipment e Use of the device is prohibited to persons known to be of unsound mind e Use of the device is prohibited to persons suffering from sensibility disorders e Use of the device is prohibited to
5. two phases 4 5 minutes intensity set above the threshold of perception to produce light internal stimulation This program for which no photographs are provided regarding the position of the electrodes requires the use of appropriate internal stimulation probes supplied separately together with the relative instructions We recommend to consult your doctor before using this program WARNING on program R07 and R08 we suggest to use certified probes class Ila medical devices Datasheet of the probes must contains how to use informations storage and cleaning precautions and any other useful informations R09 Haematomas Medical program Consult a doctor before using this program to treat haematomas Total program duration 20 minutes Few applications carried out within a few hours of the bruise A combination of various types of square wave impulses has a graduated draining effect on the area to be treated impulses at different frequencies drain the area at different depths The intensity should be adjusted to a level between the thresholds of perception and pain without causing Pag 20 USER MANUAL T ONE Medi Medi Pro cod doc MNPG06 03 MEDICAL DIVISION muscle contraction Position of electrodes form a square above the area to be treated as shown in illustration 1 12 Fitness program IMPORTANT Intensity of stimulation fitness programs Firming up Toning up Strength Resistance Endurance Agonist
6. 10 15 applications once a day the daily treatments can be doubled if required Identify the area to be treated and position the electrodes as shown in illustration 1 Adjust the intensity until a tingling feeling is produced in the area treated avoid contracting the surrounding muscles Program duration 30 minutes T10 Neck pain Headache Medical program Specific program for the treatment of pain in the neck area The intensity should be adjusted to a level between the thresholds of perception and pain the maximum intensity level is the moment in which the muscles surrounding the area treated begin to contract over this limit stimulation does not become more effective just more irritating so it is best to stop before that point The first benefits can be seen after 10 to 12 treatments carried out on a daily basis proceed with the treatment until the symptoms pass Position of electrodes photo 25 Eletcrodes Positioning cervical zone photo 25 Phase 1 Phase 2 Short width Tens impulse 30 min Decontracting 3 min T11 Backache Sciatic pain Medical program Specific program for the treatment of pain in the lumbar area or along the sciatic nerve or both The intensity should be adjusted to a level between the thresholds of perception and pain the maximum intensity level is the moment in which the muscles surrounding the area treated begin to contract over this limit stimulation does not become more effe
7. Antagonist are divided in 3 phases warm up phase work phase recovery phase During warm up phase phase1 the intensity of stimulation has to be setted so to produce a reasonable solicitation of the muscle so to warm it up without getting tired 18 30mA During work phases the middle phases of each program T ONE alternates contraction impulses with active recovery impulses The intensities of the two impulses have to be setted separately contraction intensity shown by a full bar on the display should be setted at 20 30mA for out of train people 30 50mA for trained people over 50mA for well trained people We suggest to set recovery intensity value between one contraction and another around 15 20 lower than contraction intensity value During the last recovery phase the intensity value has to be setted to produce a good massage on the stimulated part without produce pain 18 30mA F01 Firming up Indicated for firming up muscles in the arms and bust or the legs working mainly on slow twitch fibres Suitable for those who have never done any physical activity or have been inactive for a long period of time Method of use 1 identify the muscle to be treated To obtain good results it is best to treat just a few muscles at a time and complete the process described below 2 position the electrodes as shown in the photo 3 increase the intensity until the impulse can be felt use a low intensity for the first session to help
8. M01 M02 TENS memory 1 2 Medical program Available programs to set Rapid tens endorphinic tens maximum values microcurrent Position of electrodes form a square on the painful area as shown in illustration 1 Use keys g 9 to move through the menu and select the stimulation parameter use keys PED to modify the values Set all stimulation parameters position the cursor over OK to store the program e To start the stored program press key D e A three sound signal will advise of the end of the program USER MANUAL T ONE Medi Medi Pro MNPG06 03 Pag 27 C MEDICAL DIVISION Settable values chart PARAMETER DESCRIPTION MIN MAX Frequency 1 Hertz 120 Hertz Impulse width 20 microsec 450 microsec Total time 1 minute 60 minutes M03 EMS 1 second slope EMS 1 sec slope to set EMS program with 1 second impulse slope Z IMPORTANT using 1 second slope the contraction will be faster while with 2 3 seconds slope we obtain more progressive contraction Particularly for memory 5 with 3 seconds slope we obtain a triangular impulse where the impulse parameters are continuously varied This program is particularly suitable for partially denervated muscles Use keys g gt to move through the menu and select the stimulation parameter use keys EPA to modify the values 3 Set all stimulation parameters position the cursor over OK to store the program e Tostartthe stored program press k
9. White To simultaneously increase the intensity of all channels use the following buttons GD Increase D gt Decrease Skip phase press the 3 button during the working program to skip to the next phase Pause stop program during the working program press the o button once to momentarily pause the normal working cycling Press the o button again to restart the program Switch off the machine to stop the program 6 Battery charging The display shows when the battery is low of energy Batteries Batteries partially Batteries fully fully charged discharged discharged BATTERY CHARGER SPECIFICATIONS see battery charger datasheet Use only battery charger supplied by the manufacturer or by authorized dealers Using other battery chargers can seriously compromise equipment and user safety Batteries specifications use only AA type batteries like the ones supplied with the equipment rechargeable Ni Mh AA 1 2V or Alkaline AA 1 5V The manufacturer is not responsible for damages due to the use of different batteries WARNING do not recharge other batteries than the ones supplied with Ni Mh battery charger Pag 8 USER MANUAL T ONE Medi Medi Pro cod doc MNPG06 03 I TECH MEDICAL DIVISION Recharging instructions e Insert the rechargeable batteries into the charger respecting the indicated polarity e Connect the charger to the domestic plug e The batteries need 8 12 hours for a complete c
10. area concerned Position of electrodes and intensity levels The electrodes should be positioned to form a square surrounding the painful area using Channel 1 and Channel 2 as shown in illustration 1 The intensity should be adjusted to a level between the thresholds of perception and pain the maximum intensity level is the moment in which the muscles surrounding the area treated begin to contract over this limit stimulation does not become more effective just more irritating so it is best to stop before that point illustration 1 Red Red Painful A WARNING Channel 1 Channel 2 Create a square area with the alee electrodes over the painful zone Keep 4cm minimum distance BI between electrodes ack Black Pag 12 USER MANUAL T ONE Medi Medi Pro cod doc MNPG06 03 MEDICAL DIVISION T01 rapid TENS Medical program Program also called conventional tens used for analgesic purposes its purpose is to induce the organism into blocking pain at the spine in accordance with the Gate Control Theory by Melzack and Wall Pain impulses leave part of the body for example the hand and run along the nerve tracts through small diameter nerve fibres until they reach the central nervous system where the impulses are interpreted as pain Conventional tens activates large diameter nerve fibres blocking the path of small diameter nerve fibres at the spine So action is mainly taken against the symptom to simplify it further th
11. j Q MEDICAL DIVISION F04 Fast strength Speed This program is designed to increase speed in fast athletes and develop it in athletes lacking the quality The exercise assumes a fast pace and the contraction is short as is the recovery It is usually best to complete a three week basic strength cycle of increasing intensity before using this program Then continue with three weeks of fast strength three times a week at high intensity 30 50mA almost past endurance during the contraction F04 Fast strength Program duration 26 minutes Biceps photo 02 15 Triceps photo 03 16 Extensors photo 04 Flexors photo 05 Deltoid photo 06 Abdominals photo 01 20 Pectoral Breast photo 07 17 Trapezius photo 08 Large dorsal photo 09 Gluteus photo 19 Obliques photo 22 We ae oe ae ff ti Quadriceps photo 11 18 Biceps femoris photo12 Calves photo13 Anterior tibial photo14 Phase 1 Phase 2 Phase 3 Phase 4 10 min 8 min 3 min warm up 14 sec recovery 10 sec recovery 5 min recovery 6 sec work 5 sec work F05 Explosive strength Explosive strength programs increase the explosive power and speed of the muscle mass with extremely short strengthening contractions and very long active recovery times to allow the muscle to regain strength It is usually best to complete a three week basic strength cycle of increasing intensity before using this program Then continue with three wee
12. must not be used when they no longer stick to the skin in fact it can cause skin redness that can last for many hours after stimulation Consult a doctor if this occurs 16 Technical specifications Risk class Class Il in accordance with the 93 42 EEC directive Insulation class Internally powered device with type BF applied parts in accordance with the CEI EN 60601 1 standard Classification IP30 based on the penetration of liquids and powder equipment not protected Housing ABS Power Supply 4 AA Alkaline batteries 1 5V or 4 AA Ni Mh batteries 1 2V Average consumption 1W Limitations equipment not suitable for use in environments with a high concentration of oxygen and or flammable liquids and or flammable gas do not use with equipment for electrosurgery or short wave or microwave therapy Operation equipment suitable for continuous operation Output channel 4 channels independent and galvanically isolated Output current peak to peak 218mA maximum power 31mA max effective per single channel with load from 200 ohm to 1Kohm Type of impulse rectangular and compensated biphasic rectangular Frequency operates with a range of impulses from 0 5 Hz to 1500 Hz Impulse amplitude from 40us to 900us sum of the two semi impulses Display reflective LCD display 128x64 pixel Control keypad 10 key soft touch keypad Dimensions 125 x 76 x 34 mm Weight 280 gr including batteries Battery charger see cha
13. the description of the single programs We recommend that you record the level of intensity reached in order to try to improve the level of stimulation and consequently your performance Massage winding down active recovery impulse intensity must be adjusted gradually to massage the muscle treated The level of intensity should be sufficient to obtain a comfortable massage Bear in mind that there is no need to endure high intensity levels in this case as it is meant to be a massage meaning that intensity can be increased gradually without excesses Capillarization impulse increase the intensity gradually to produce constant visible stimulation of the area treated a medium stimulation threshold is recommended always below the pain threshold USER MANUAL T ONE Medi Medi Pro MNPG06 03 Pag 11 Q MEDICAL DIVISION 10 T E N S Programs The product conforms to the 93 42 EEC directive concerning medical devices for the following programs WARNING It must be remembered that an electronic stimulator is a very effective analgesic instrument and that pain can indicate various types of medical conditions The Tenst to Tens20 programs described in this paragraph are analgesic You are advised to read the manual carefully before using T ONE REMEMBER THAT PAIN IS A SIGN consult a doctor to identify the medical condition before using T ONE TENS an acronym standing for transcutaneous electrical nerve stimulation
14. the intensity must be strong enough to produce a relevant perception near pain till the muscles surrounding the area treated begin to contract Lipolysis drainage impulse the pump effect is produced by sequential tonic contractions The intensity must be enough to produce these contractions the greater the contraction is the greater the pump effect will be But beware there is no benefit to be gained from enduring intensity high enough to cause pain The first electrostimulation sessions should be carried out at a low intensity to allow the organism to get used to new sensations That way intensity can be increased gradually and will not be traumatic Warming up impulse in this case stimulation intensity must be increased gradually to increase the metabolism of the muscle concerned gradually A bit like with a car the engine needs warming up before it is taken to full speed Toning training atrophy contraction impulse the muscle treated must visibly contract during a training impulse The fact that the muscle tends to stiffen and increase in volume will be visible to the naked eye Intensity should be increased gradually in the first contraction to enable you to identify the right level of stimulation comfort Intensity can be increased up to the personal tolerance threshold during the second training contraction this operation is then repeated during each contraction until the workload reaches the level of intensity recommended in
15. 4 5 min warm u 12min Temin 5 min recove P 13 sec recovery 7 sec work 13 sec recovery 7 sec work y F03 Basic strength The Basic strength program is used in sport to develop basic strength of a muscle The contractions alternate with periods of active recovery during the work phase allowing the muscle to be trained without subjecting it to stress and improving oxygenation of the same muscle The following basic procedure will enable you to obtain the first results two sessions per week for each muscle region for the first three weeks at medium low intensity three sessions per week for the next three weeks at high intensity Intensity must be increased gradually treatment by treatment Suspend training for a few days in the event of fatigue and proceed with the F09 Recovery program F03 Basic strength Program duration 30 minutes Biceps photo 02 15 Triceps photo 03 16 Extensors photo 04 Flexors photo 05 Deltoid photo 06 Abdominals photo 01 20 Pectoral Breast photo 07 17 Trapezius photo 08 Large dorsal photo 09 Gluteus photo 19 Obliques photo 22 Be ae oe ae HH ti Quadriceps photo 11 18 Biceps femoris photo12 Calves photo13 Anterior tibial photo14 Phase 1 Phase 2 Phase 3 Phase 4 10 min 10 min 5 min warm up 13 sec recovery 14 sec recovery 5 min recovery 7 sec work 6 sec work Pag 22 USER MANUAL T ONE Medi Medi Pro cod doc MNPG06 03
16. CAL DIVISION must be adjusted to produce good muscle contraction in the area treated Position of electrodes from photo 1 to photo 20 Program duration 30 minutes R03 Atrophy prevention Program duration 30 minutes Biceps photo 02 15 Triceps photo 03 16 Extensors photo 04 Flexors photo 05 Deltoid photo 06 Abdominals photo 01 20 Pectoral Breast photo 07 17 Trapezius photo 08 Large dorsal photo 09 Gluteus photo 19 Obliques photo 22 We a ee ae ff ff Quadriceps photo 11 18 Biceps femoris photo12 Calves photo13 Anteriore tibial photo14 Phase 1 Phase 2 Phase 3 Phase 4 10 min 10 min 5 min warm up 9 sec recovery 9 sec recovery 5 min recovery 6 sec work 6 sec work R04 Atrophy trophism rehabilitation Medical program This program acts selectively on slow twitch fibres Ideal for recovering muscle trophism after a long period of inactivity or an accident Program to be carried out when loss of muscle tone has already occurred Apply with caution at low intensity enough to produce light muscle contractions in the first 2 3 weeks Increase intensity progressively over the next 3 4 weeks Application on alternate days Position of electrodes from photo 1 to photo 20 Program duration 30 minutes R04 Atrophy Program duration 25 minutes EA LI Biceps photo 02 15 Triceps photo 03 16 Extensors photo 04 Flexors photo 05 Deltoid photo 06 Ab
17. ON F06 Resistant strength Program duration 30 minutes EA LI Biceps photo 02 15 Triceps photo 03 16 Extensors photo 04 Flexors photo 05 Deltoid photo 06 Abdominals photo 01 20 Pectoral Breast photo 07 17 Trapezius photo 08 Large dorsal photo 09 Gluteus photo 19 Obliques photo 22 We ae ee ae ff ti Quadriceps photo 11 18 Biceps femoris photo12 Calves photo13 Anterior tibial photo14 Phase 1 Phase 2 Phase 3 Phase 4 10 min 10 min 5 min warm up 20 sec recovery 20 sec recovery 5 min recovery 10 sec work 10 sec work F07 Resistance Endurance The Resistance program is used in sports to increase muscle resistance acting mainly on slow twitch fibres Program indicated for endurance sports marathon runners cross country skiers ironman etc Program duration 50 minutes Stimulation intensity during the contraction if not particularly fit start with a low intensity then increase gradually For practised athletes the intensity used should be enough to produce visible muscle contractions In the event of muscle ache after stimulation use the FO9 Recovery program F07 Resistance Endurance Program duration 50 minutes EA KA Biceps photo 02 15 Triceps photo 03 16 Extensors photo 04 Flexors photo 05 Deltoid photo 06 Abdominals photo 01 20 Pectoral Breast photo 07 17 Trapezius photo 08 Large dorsal photo 09 Gluteus photo 19 O
18. Position of electrodes above the painful area as shown in illustration 1 T07 Vascularization Medical program Has a vascularizing effect on the area treated Vascularization increases arterial flow and consequently aids the removal of algogenic substances and helps to restore normal physiological conditions Do not position the electrodes close to inflamed areas Daily application is recommended the number of applications is not defined the program can be used to reduce pain Stimulation intensity should be between the thresholds of perception and slight discomfort Program duration 20 minutes Position of electrodes see photo 25 and 33 in the manual of positions Pag 14 USER MANUAL T ONE Medi Medi Pro cod doc MNPG06 03 MEDICAL DIVISION T08 Decontracting Medical program Program used to speed up the recovery of muscle function after intense training or strain from work the effect is immediate Adjust the intensity for moderate muscle solicitation Two treatments per day for three or four days Program duration 35 minutes Position of electrodes from photo 1 to 28 T08 Decontracting Electrodes positioning Create a square area with the electrodes over the painful zone Phase 1 Phase 2 Short width Tens impulse 15 min Large width Tens impulse 20 min T09 Anti inflammatory Medical program Program recommended for inflammatory conditions To be applied until the inflammatory state is lessened
19. That is the reason why such stimulation is undoubtedly the least tolerated but is extremely effective This type of stimulation is not recommended for particularly sensitive people and in any case the electrodes should not be positioned in sensitive areas such as the face and genitals or close to wounds Position of electrodes form a square above the painful area as shown in illustration 1 T05 TENS Burst impulse Medical program This program produces a training effect using the frequencies of conventional TENS Useful for pain therapy The action is similar to the one of endorphinic TENS with a treatment time of 15 minutes for a phase Position of electrodes form a square above the painful area as shown in illustration 1 T06 Microcurrent Medical program The use of microcurrent is very similar to conventional Tens the only difference is the use of the very fine electric impulse more suitable for the sensibility of slightly anxious people or for more delicate parts of the body It can generally be applied for everyday pains bearing in mind that you should always consult your doctor to identify the cause of the pain It is considered a good all purpose analgesic current as it does not have any side effects except slight skin redness after long applications and has very few contraindications those specified in the paragraph at the beginning Program duration 30 minutes Intensity set above the threshold of perception
20. USER MANUAL vi ao model MEDI amp MEDI PRO MNPGO6 Rev 03 02 12 2011 MEDICAL DIVISION WARNING T ONE IS A MEDICAL DEVICE Consult your doctor before using T ONE if you suffer from health problems Read the contraindications and warnings carefully before using the medical programs C 0476 Manufactured in compliance with the 93 42 EEC directive concerning medical devices by IACER S r l via Pertini 24 A 30030 Martellago VE iacer iacer it www itechmedicaldivision com Pag 2 USER MANUAL T ONE Medi Medi Pro cod doc MNPG06 03 j Q MEDICAL DIVISION USER MANUAL TABLE OF CONTENTS 1 T ONE kit contents Page 4 2 Purpose Page 4 Contraindications and side effects 3 Warnings Page 5 4 Legend of symbols marked on T ONE and found in the manual Page 6 5 Howto use T ONE Page 6 Description of controls Preliminary instructions Operating instructions 6 Battery charging Page 8 7 T ONE maintenance and storage Page 10 8 Resolution of problems and questions Page 10 9 Electrostimulation and T ONE stimulation intensities Page 11 10 T E N S programs Page 12 11 REHAB programs Page 18 12 FITNESS programs Page 21 13 Custom programs only model MEDI PRO Page 27 14 SET UP Page 29 15 Self adhesive electrodes Page 30 16 Technical specifications Page 30 17 Assistance Page 31 USER MANUAL T ONE Medi Medi Pro MNPGO6 03 Pag 3 MEDICAL DIVISION 1 T ONE kit contents 1 T ONE electronic s
21. al phasic contractions 2 This program produces rhythmic contractions with a stimulation frequency typical of fast twitch fibres Thanks to the high stimulation frequency it is suitable for increasing muscle strength sequentially The programs produce sequential phasic contractions on four channels Stimulation intensity must be sufficient to produce good muscle contractions during the treatment but not enough to cause any soreness Unlike the previous program this one uses a higher stimulation frequency during the contraction phase and therefore works mainly on fast twitch fibres R06 Sequential prasi contractions 2 Program duration 25 minutes Muscles all you want to stimulate in a sequence Phase 1 Phase 2 Phase 3 Phase 4 10 min sequential 10 min sequential 3 min warm up contractions on 4 channels 6 contractions on 4 channels 6 2 min recovery sec duration each sec duration each R07 Stress incontinence Medical program Program duration 9 minutes two phase 4 5 minutes intensity set above the threshold of perception to produce light internal stimulation This program for which no photographs are provided regarding the position of the electrodes requires the use of appropriate internal stimulation probes supplied separately together with the relative instructions We recommend to consult your doctor before using this program R08 Urgency incontinence Medical program Program duration 9 minutes
22. ase 2 Phase 3 20 min 3 min warm up 6 sec recovery 10 min recovery 7 sec work on CH1 CH2 7 sec work on CH3 CH4 F11 Lipolysis These specific drainage program increase microcirculation within and around the muscle fibres treated and create rhythmic contractions facilitating the discharge of algogenic substances and promoting lymphatic activity It can also be applied to older people to improve blood and lymphatic circulation The program produces sequential tonic contractions before CH1 and CH2 after CH3 and CH4 reproducing the typical effect of electronic lymphatic drainage There are no real limits of application for this program which can be practiced until the desired result has been achieved Stimulation intensity must be sufficient to produce good muscle contractions during the treatment but not enough to cause any soreness Duration 30 minutes The first results can usually be seen after 3 4 weeks practicing 4 5 sessions a week USER MANUAL T ONE Medi Medi Pro MNPG06 03 Pag 25 j Q MEDICAL DIVISION Upper CH1 on Extensors photo 04 only 2 electrodes CH2 on Flexors photo 05 only 2 electrodes muscles CH3 on Biceps photo 02 only 2 electrodes CH4 on Triceps photo 03 only 2 electrodes Lower CH1 on Calves photo 13 only 2 electrodes CH2 on Anterior tibial photo 14 only 2 electrodes CH3 on Quadriceps photo 11 only 2 electrodes CH4 on Biceps femoris photo 12 only 2 muscles electrodes Phase 1 Pha
23. bliques photo 22 We ae oe ae i ti Quadriceps photo 11 18 Biceps femoris photo12 Calves photo13 Anterior tibial photo14 Phase 1 Phase 2 Phase 3 Phase 4 20 min 10 min 5 min warm up 20 sec recovery 22 sec recovery 5 min recovery 10 sec work 8 sec work F08 Capillarization This program significantly increases arterial flow in the area treated Prolonged use of this program develops the intramuscular capillary network of fast twitch fibres The effect obtained is an increase in the capacity of fast twitch fibres to withstand strain over extended periods of time For an athlete with good resistance the capillarization program is very useful for recovery after intense aerobic work before anaerobic work and when training is not possible due to bad weather or an injury Program duration 30 minutes one phase Recommended stimulation intensity medium Position of electrodes see photos 01 to 20 in the manual of positions in relation to the area that you wish to stimulate Pag 24 USER MANUAL T ONE Medi Medi Pro cod doc MNPG06 03 j Q MEDICAL DIVISION F09 Muscle recovery Can be used for all sports after competitions or the most demanding training sessions in particular after long and intense exertion To be used immediately after exertion Helps drainage and winding down improving muscle oxygenation and helping to discharge synthetic substances produced during exertion Program duration
24. ctive just more irritating so it is best to stop before that point The first benefits can be seen after 15 to 20 treatments carried out on a daily basis proceed with the treatment until the symptoms pass Program duration 35 minutes Position of electrodes see photo 27 and 28 in the manual of positions T11 Lumbal sciatic pain Program duration 35 minutes Electrodes positioning lumbal area photo 27 sciatic area photo 28 Phase 1 Phase 2 Short width Tens impulse 30 min Tens Burst impulse 5 min USER MANUAL T ONE Medi Medi Pro MNPG06 03 Pag 15 MEDICAL DIVISION T12 Sprains Bruises Medical program The program develops its effectiveness after this type of injury by inhibiting pain locally producing three selectively acting differentiated impulses The intensity should be adjusted to a level between the thresholds of perception and pain Number of treatments until pain is lessened on a daily basis even 2 3 times a day Electrodes positioning ankle photo 32 Phase 1 Phase 2 Tens rapid 15 min Emathoma impulse 15 min T13 Hand and wrist pain Medical program This program is suitable for all types of hand and wrist pain aching caused by strains arthritis in the hand carpal tunnel syndrome etc Total program duration 40 minutes A combination of various types of square wave impulses has a general analgesic effect on the area to be treated impulses at different frequencies
25. d by the manufacturer will free the same from any responsibility related to damage to the equipment or user and will expose the user to risks such as short circuits and fire e It is forbidden to position the electrodes in such a way that the current crosses the heart area e g a black electrode on the chest and a red electrode on the shoulder blade however electrodes can be positioned along the muscular fascia of the heart area as used for pectoral strengthening e Use of the device is prohibited with electrodes positioned on or close to injuries or cuts e The electrodes must not be positioned on the carotid sinuses carotid or genitals The electrodes must not be positioned close to the eyes make sure that the current delivered does not cross the eyeball one electrode diametrically opposite to the other in relation to the eye keep a distance of at least 3 cm from the eyeball e When using the electrodes follow the instructions given in this manual and on the package of the electrodes themselves Use single patient electrodes supplied exclusively by the manufacturer or retailer and take great care to avoid the exchange of electrodes between different users T ONE has been tested and guaranteed for use with the electrodes supplied Insufficiently sized electrode sections can cause skin reactions or burns Only use the round electrodes supplied by the manufacturer for facial applications e Do not use electrodes when damaged even i
26. de with the drug on painful area and the other electrode horizontally Program duration 20 minutes Select channel 1 or channel 2 select both channel only if you need to stimulate two different areas Position the electrodes positive and negative horizontally to the treatment area Channel 3 and channel 4 are disconnected Set up an intensity value so to have pins and needles on treatment area At the end of the program the skin could lightly turn bright red the reddening usually vanishing few minutes after the end of program Program 1 works at 1000 Hz program 2 works at 1500 Hz Program 2 has a stronger action in carry drugs trough skin than program 1 but also has a higher probability of skin reddening Do not use ionophoresis program near metallic prosthesis CATHODE ANODE drug skin R03 Atrophy prevention Medical program Program created to maintain muscle trophism This treatment concentrates on muscle toning paying particular attention to slow twitch fibres Particularly indicated for patients recovering from an accident or an operation Prevents the reduction of muscle trophism caused by physical inactivity The muscle area concerned can be stimulated with daily applications of medium intensity if you increase the intensity leave a day of rest between applications to allow the muscles to recover The intensity of this program Pag 18 USER MANUAL T ONE Medi Medi Pro cod doc MNPG06 03 j MEDI
27. dominals photo 01 20 Pectoral Breast photo 07 17 Trapezius photo 08 Large dorsal photo 09 Gluteus photo 19 Obliques photo 22 hip photo 23 We ae ee ae ff ti Quadriceps photo 11 18 Biceps femoris photo12 Calves photo13 Anteriore tibial photo14 Phase 1 Phase 2 Phase 3 3 min warm u Sl 2 min recove P 6 sec recovery 6 sec work y RO5 Sequential tonic contractions 1 This program increases microcirculation within and around the muscle fibres treated creating rhythmic contractions fostering better drainage and toning It can also be applied to older people to improve blood and lymphatic circulation in the lower limbs e g applying CH1 to the right calf CH2 to the left calf CH3 to the right thigh CH4 to the left thigh These programs can be carried out using self adhesive electrodes Stimulation intensity must be sufficient to produce good muscle contractions during the treatment but not enough to cause any soreness lt mainly works on slow twitch fibres USER MANUAL T ONE Medi Medi Pro MNPG06 03 Pag 19 j Q MEDICAL DIVISION R05 sequential tonic contractions 1 Program duration 25 minutes Muscles all you want to stimulate in a sequence Phase 1 Phase 2 Phase 3 Phase 4 10 min sequential 10 min sequential 3 min warm up contractions on 4 channels 6 contractions on 4 channels 6 2 min recovery sec duration each sec duration each R06 Sequenti
28. e current intensity until the personal tolerance level is reached Selected Total Phases Battery charge program working phase Phase countdown indicator Working Recovery work program indicator bar BU KW ococo 15 00 m Endurance Output nnn lO connection error working aon g fon A OFF Weve a Xe mA USER MANUAL T ONE Medi Medi Pro MNPGO6 03 Pag 7 j MEDICAL DIVISION A bar indicating the start and end of a contraction will appear on the display whilst the electronic stimulator is working The periods of muscular contraction bold bar and the periods of recovery dotted or striped bar are graphically visualised under the bar with a cursor This enables the user to know exactly when a contractions starts 8 At the end of the first phase the T ONE cancels the previously selected intensity and warns the user with an intermittent signal to continue with the program press the A button for the relevant channels again until you reach the desired level of stimulation An audio signal will sound three times when the program has finished 9 At the end of the program switch off the T ONE and remove the cables Attach the electrodes to the transparent films and replace them in their original packaging Option to simultaneously increase the intensity on all channels Select the desired program Start program Increase each channel to at least intensity 1 A A A CHI i CH2 CH3 CH4 Blue Yellow Red
29. e wire transmitting pain information is obstructed Treatment duration should be no less than 30 40 minutes Conventional tens is a current that can be used to treat general everyday pain The average number required to benefit from the treatment is 10 12 per day there are no contraindications for up to double this amount The program has a duration of 40 minutes in a single phase The program can be repeated at the end of the session for particularly persistent pain The nature of the impulse means that the patient may experience an addictive effect due to which the impulse will be felt less and less if necessary the intensity can be increased by one level to counter this effect Position of electrodes form a square above the painful area as shown in illustration 1 T02 endorphinic TENS Medical program This type of stimulation produces two types of effects according to how the electrodes are positioned positioning the electrodes in the dorsal region see photo 08 in the positions manual promotes the endogenous production of morphine like substances capable of raising the pain perception threshold positioning the electrodes to form a square above the painful area as shown in illustration 1 produces a vascularizing effect Vascularization increases arterial flow and consequently aids the removal of algogenic substances and helps to restore normal physiological conditions Treatment duration 30 minutes in a single phase daily frequ
30. ency Do not position the electrodes close to inflamed areas Intensity adjusted for good solicitation of the part stimulated the sensation must be similar to that of a massage USER MANUAL T ONE Medi Medi Pro MNPG06 03 Pag 13 MEDICAL DIVISION T03 TENS sequential Medical program The action of this program is very similar to the one of T01 program During stimulation this program modifies by itself the frequency and impulse width so to contrast the habit at the stimulation no need to continuously adjust the intensity value Select the intensity at the beginning of the program and maintain it till the end of the program In the event during the program current perception decreases a lot do not increase intensity value and wait till the end of therapy TENS program is working properly Program duration 20 minutes for each phase Intensity set above the threshold of perception Position of electrodes form a square on the painful area as shown in illustration 1 or see pictures from 25 to 33 T04 TENS at maximum values Medical program Very short duration 3 minutes Blocks pain impulses peripherally creating a proper anaesthetising effect in the area treated This type of stimulation is suitable for injuries or bruises when rapid action is required The intensity selected is the maximum tolerable value well in excess of conventional tens and therefore with considerable contraction of the muscles surrounding the area treated
31. ency 20 Hertz 120 Hertz Contraction time 6 seconds 10 seconds Recovery frequency 1 Hertz 12 Hertz Recovery time 2 seconds 20 seconds Impulse width 60 microseconds 450 microseconds Total time 1 minute 60 inutes 14 SET UP Selecting the language and contrast level on the display Turn T ONE on using the button and immediately after keeping pressed the button until the language list appears on the display Release the button now use the mouse to move the cursors and choose the desired language or the level of contrast on the display Select the chosen language by using the LW buttons Adjust the level of contrast on the display by using the g 9 buttons Press to confirm your selections USER MANUAL T ONE Medi Medi Pro MNPG06 03 Pag 29 I TEGR DIVISION 15 Self adhesive electrodes The position of the electrodes is shown in the manual of electrode positions The electrodes supplied are top quality pre gelled and ready for use they are particularly suitable for electrostimulation treatments They are very flexible making it easy to treat all areas Remove the protective plastic from the electrode before use position it on the skin as shown in the manual and replace the plastic after use Electrode duration is determined by the skin s pH value we recommend no more than 10 15 applications using the same electrode Repeated use of the same electrodes can compromise stimulation safety which is why electrodes
32. ey amp e A three sound signals will advise of the end of the program Selected Phase number Impulse width Countdown program i ee val M03 f Indication bar Program a HH 35 00 Es contractions and active name EMS 1 second slope as Sas 3004S ecoven Contraction DONE Hii oo wb frequency time Recover ABS 4Hz 105 1 isle H2 Contraction frequency time Description fici petra of selected and start program Oarameter Settable values chart PARAMETER DESCRIPTION MIN MAX Contraction frequency 20 Hertz 120 Hertz Contraction time 2 seconds 10 seconds Recovery frequency 1 Hertz 12 Hertz Recovery time 2 seconds 20 seconds Impulse width 60 microseconds 450 microseconds Total time 1 minute 60 minutes Pag 28 USER MANUAL T ONE Medi Medi Pro cod doc MNPG06 03 j Q MEDICAL DIVISION M04 EMS 2 seconds slope EMS 2 sec slope to set EMS program with 2 second impulse slope Settable values chart PARAMETER DESCRIPTION MIN MAX Contraction frequency 20 Hertz 120 Hertz Contraction time 4 seconds 10 seconds Recovery frequency 1 Hertz 12 Hertz Recovery time 2 seconds 20 seconds Impulse width 60 microseconds 450 microseconds Total time 1 minute 60 minutes M05 EMS 3 seconds slope EMS 3 sec slope to set EMS program with 3 second impulse slope Settable values chart PARAMETER DESCRIPTION MIN MAX Contraction frequ
33. f they stick to the skin well e Electrodes must not be used when they no longer stick to the skin Repeated use of the same electrodes can compromise the safety of the stimulation in fact it can cause skin redness that can last for many hours after stimulation Warning During treatment with round and 35 x 45 mm electrodes current density may be in excess of 2 mA cm for each electrode In these cases take special care regarding any skin redness e Do not use anal or vaginal probes in event of skin or muscle injuries Do not use without a medical prescription USER MANUAL T ONE Medi Medi Pro MNPGO6 03 Pag 5 I TECH MEDICAL DIVISION 4 Legend of symbols marked on T ONE and found in the manual C E0476 bbe mS gt do lt p Manufactured in compliance with the 93 42 EEC directive concerning medical devices Internally powered device with type BF applied parts Product subject to WEEE regulations concerning separate waste collection Read the instructions for use carefully before using the device ON OFF button Select program and muscles to stimulate Multifunction buttons select Sport Beauty or Tens program male female and skip phase Start Stop program confirm selection and pause Increase intensity Decrease intensity 5 How to use T ONE Startistop ram confirm Faleciion _ graphic LCD Select rams and muscles Switch ON OFF Select Sport Beau Tens p am ee Select Sport Beauty ma
34. g joints tendons serous sacs and connective tissue These appear altered and can break into fragments and calcify If neglected this condition can become heavily crippling For this reason after carrying out a cycle of 15 20 applications once a day we recommend that you consult your doctor for a cycle of specific rehabilitation exercises to reduce the pain The Tens17 program consists of various phases including Tens and muscle stimulation aimed at improving the tone of the muscles surrounding the joint Program duration 41 minutes intensity set above the threshold of perception with small muscle contractions at the end of the program 10 minutes before the end T17 Periarthritis Program duration 41 minutes Electrodes positioning periarthritis foto 26 Phase 1 Phase 2 Phase 3 Tens 150Hz 1 min Tens 90Hz 30 min Muscle stimulation 10 min T18 Heaviness in legs This program is used to improve blood flow and muscle oxygenation speeding up the elimination of lactic acid produced after anaerobic sessions for muscle definition reducing soreness and the risk of contractures Thanks to this program the muscle treated will be ready for a new training session or competition much more quickly Program duration 25 minutes Recommended initial intensity medium low enough to produce good movement of the part treated increase intensity progressively until the muscle treated is subjected to a strong massage Position of e
35. harge e During charging both batteries and charger get warm this is a normal condition and do not imply any danger N WARNING disconnect the battery charger from domestic plug when not in use Do dot immerge the battery in water or other liquids and do not expose it to heat sources Do not dispose of discharged or defective batteries with domestic waste dispose of in an authorised waste collection bin Before storing T ONE for long periods of time we recommend that it is fully charged and stored in a dry place checking that it is switched off Do not use the battery charger if e The plug is damaged or parts of it are broken e It has been exposed to rain or any other type of liquid e The components have been damaged by a fall Do not immerge the battery charger in water Use a dry cloth to clean the battery charger Do not open the battery charger it does not contain repairable parts USER MANUAL T ONE Medi Medi Pro MNPGO6 03 Pag 9 C I T DIVISION 7 T ONE maintenance and storage We recommend that T ONE is switched off and the cables are removed from the connectors at the end of every session T ONE should be kept in the carry bag supplied together with the rest of the equipment supplied with it and carefully stored on a secure surface and protected from situations listed in the Warnings paragraph T ONE should be stored in the following conditions Temperature from 20 to 40 Maximum relative humidity 75
36. ks of explosive strength twice a week During the contraction the intensity must be the highest that can be endured in order to obtain maximum muscle exertion whilst involving the greatest number of fibres over 35mA F05 Explosive strength Program duration 28 minutes EA I Biceps photo 02 15 Triceps photo 03 16 Extensors photo 04 Flexors photo 05 Deltoid photo 06 Abdominals photo 01 20 Pectoral Breast photo 07 17 Trapezius photo 08 Large dorsal photo 09 Gluteus photo 19 Obliques photo 22 fji H Quadriceps photo 11 18 Biceps femoris photo12 Calves photo13 Anterior tibial photo14 Phase 1 Phase 2 Phase 3 Phase 4 10 min 10 min 3 min warm up 24 sec recovery 24 sec recovery 5 min recovery 6 sec work 6 sec work F06 Resistant strength Long effort This program is designed to help increase resistance to physical stress or rather withstand intense exertion for a longer amount of time in muscle regions subjected to stimulation Indicated for sporting disciplines involving long intense periods of exertion Stimulation intensity during the contraction start with a low level of intensity increasing it gradually For practised athletes the intensity used should be enough to produce visible muscle contractions In the event of muscle ache after stimulation use the FO9 Recovery program USER MANUAL T ONE Medi Medi Pro MNPG06 03 Pag 23 j Q MEDICAL DIVISI
37. lastic protection has been removed from the electrode e Check that the cables have been connected correctly connector well inserted in the device T ONE switches off during operation e Recharge the batteries and start the treatment again If the problem persists contact the manufacturer Disposal To protect the environment the device its accessories and above all the batteries must be disposed of in areas equipped for that purpose or as special waste A Product subject to WEEE regulations concerning separate waste collection Pag 10 USER MANUAL T ONE Medi Medi Pro cod doc MNPG06 03 MEDICAL DIVISION 9 Electrostimulation and stimulation intensity Electrostimulation consists of the transmission of electric microimpulses to the human body Fields of application of electrostimulation are pain therapy recovery of muscle trophism after injury or a surgical operation athletic preparation and beauty treatments Specific electric impulses are used for every one of these applications The stimulation intensity is displayed on the T ONE screen for each channel in a scale progressing from 0 to 120 The types of impulses can be classified as follows 1 Tens impulse for tens programs the intensity should be adjusted to a level between the thresholds of perception and pain The maximum limit is reached when the muscles surrounding the area treated begin to contract It is best to stay below that limit lonophoresis impulse
38. le female Tens program mate and female increase intensity Decrease intensity ___ Dulput Ch oing OIR rr E put Cha Pag 6 USER MANUAL T ONE Medi Medi Pro cod doc MNPG06 03 I TECH MEDICAL DIVISION Preliminary instructions Before using T ONE clean the skin of the area to be treated with the cable disconnected from T ONE connect the electrostimulation cable jacks to the self adhesive electrodes position the self adhesive electrodes on the skin see photos of electrode positions connect the impulse transmission cables to the relative jacks Channel 1 and or Channel 2 then turn T ONE on Warning make sure that T ONE is switched off before disconnecting the electrodes at the end of the treatment Operating instructions N B read the whole manual before using the equipment 1 Turn T ONE on using the button 2 Select the program group Sport Beauty Tens Mem only Medi Pro version using the button 3 Select the program using the gt LW buttons 4 Select male or female with g 9 buttons Male selection Female selection 5 Select the muscle group with GD GOW buttons tn Arms male trunk Legs male Arms female trunk Legs female male female 6 press to start program the display shows connect cables and electrodes and increase intensity of the used channels to start intensity press A for each used channel T ONE will begin the session 7 press the A button for each use channel to increas
39. lectrodes see photos 01 to 20 in the manual of positions T18 Heaviness in legs Program duration 25 minutes Electrodes positioning photo 21A and 21B Phase 1 Phase 2 Phase 3 EMS 10 min Tens 3Hz 5 min Tens 1Hz 10 min USER MANUAL T ONE Medi Medi Pro MNPG06 03 Pag 17 I TECH MEDICAL DIVISION 11 REHAB Programs R01 R02 lonophoresis 1 lonophoresis 2 Medical program lonophoresis is an electrotherapic technique that uses continuous current to carry drugs into painful area or contracture area lonophoresis means ions transport through continuous current active pharmacologic ions are driven through the skin Electric current favours drugs penetration into the cells and at the same time it stimulates the elimination of metabolic slag The drug can have negative polarity positive polarity or double polarity The current induce the drug to run from one pole to the other crossing the painful area and releasing the specific active ingredient WARNING before starting the therapy wet the sponge electrodes and wring them so to avoid dripping then put the drug on the electrode as follow e Active polarity drug dissolve this drug on the electrode connected to positive pole red connector e Negative polarity drug dissolve this drug on the electrode connected to negative pole black connector e Double polarity drug can be dissolved on positive pole or negative pole without distinction Position the electro
40. n from reoccurring Program duration 40 minutes intensity adjusted above the threshold of perception Position of electrodes photo 29 Electrodes positioning photo 29 Phase 1 Phase 2 Phase 3 Tens 90Hz 20 min Tens 70Hz 10 min Tens 50Hz 10 min Pag 16 USER MANUAL T ONE Medi Medi Pro cod doc MNPG06 03 MEDICAL DIVISION T16 Epitroclea Medical program Also known as golfing elbow it affects golfers but also those who carry out repetitive tasks or tasks involving frequent intense strain for example carrying a particularly heavy suitcase It causes pain in the flexor and pronator tendons inserted in the epitroclea Pain is felt when bending or straightening the wrist against resistance or when clenching a hard rubber ball in the hand 15 applications once a day even twice until the symptoms pass We recommend that you consult your doctor to identify the precise cause of the pain in order to prevent the condition from reoccurring Program duration 40 minutes intensity set above the threshold of perception Position of electrodes photo 29 but with all of the electrodes positioned on the inside of the arm with a rotation of about 909 Electrodes positioning photo 29 with electrodes rotated 90 Phase 1 Phase 2 Tens 90Hz 20 min Tens 70Hz 20 min T17 Periarthritis Medical program Scapulo humeral periarthritis is an inflammatory condition affecting the fibrous tissues surroundin
41. oderate physical activity Method of use 1 identify the muscle to be treated To obtain good results it is best to treat just a few muscles at a time and complete the process described below 2 position the electrodes as shown in the photo 3 increase the intensity until the impulse can be felt use a medium intensity for the first session to help you understand how the machine works 4 during the program and over the next few days the intensity should be increased gradually to produce marked muscle contractions 5 during machine contractions contract the muscle voluntarily 6 acycle of 15 20 applications must be completed before the first results can be seen one application for each muscle every two days with a day of rest in between It is possible to work on pairs of muscles for example thighs and abdominal muscles treating one set one day and the other the next day Working on too many muscles at the same time is not recommended A bit at a time but consistently F02 Toning up Program duration 34 minutes Biceps photo 02 15 Triceps photo 03 16 Extensors photo 04 Flexors photo 05 Deltoid photo 06 mn pi Abdominals photo 01 20 Pectoral Breast photo 07 17 Trapezius photo 08 Large dorsal photo 09 Gluteus photo 19 Obliques photo 22 We ae ee ae ff fi Quadriceps photo 11 18 Biceps femoris photo12 Calves photo13 Anterior tibial photo14 Phase 1 Phase 2 Phase 3 Phase
42. ollowing program with a duration of 15 minutes is used to tone facial muscles using a special impulse to improve both the appearance and the dynamism of facial muscles The position of the electrodes is shown in the manual of electrode positions photo 24 N B a minimum distance of 3 cm must be kept between the electrode and the eyeball N IMPORTANT take care when adjusting the intensity as facial muscles are particularly sensitive intensity should be increased gradually starting with a very low level of stimulation just above perception and increasing with extreme care until you reach a good level of stimulation represented by good muscle activation IMPORTANT it is not necessary to reach levels of intensity capable of causing discomfort The equation more pain more gain is completely misleading and counterproductive Great and significant results are obtained through consistency and patience Pag 26 USER MANUAL T ONE Medi Medi Pro cod doc MNPG06 03 MEDICAL DIVISION 13 T ONE MEDI PRO programmable memories Operative instructions reserved to medical personnel or therapists 1 Switch on T ONE keeping pressed key Oi at least 1 second 2 Select MEM on menu pressing 3 times key Proceed on choosing the desire memory using keys 2D GD 4 Press key D to enter selected memory and change the stimulation parameters kH 30 00 EJ TENS memory TENS memory 2 EMS 2 seconds slope EMS 3 seconds slope
43. permanently or temporarily disabled persons unless assisted by qualified personnel e g a doctor or therapist e Use of the device is prohibited in the presence of signs of deterioration of the device itself Should any foreign matters penetrate the device contact the retailer or manufacturer immediately If dropped check that the housing is not cracked or damaged in any way if so contact the retailer or manufacturer Should you notice any changes in the device s performance during treatment interrupt the treatment immediately and consult the retailer or manufacturer patients being treated in a centre must also be informed of the event e Use of the device is prohibited in combination with other medical devices e Use of the device is prohibited close to flammable substances or in environments with high concentrations of oxygen e Consult a doctor before using T ONE with metallic osteosynthesis devices Muscle heaviness and cramps may be experienced in the event of prolonged muscle stimulation Should this occur we recommend suspending treatment with T ONE for a few days and then continuing with muscle recovery and capillarization programs Make sure that the plug and battery charger are intact Should one of these parts show any sign of damage suspend use of the battery charger immediately and contact the retailer or manufacturer Only use battery chargers supplied by the manufacturer the use of battery chargers not supplie
44. rger instruction Maintenance and storage refer to the instructions in Chapter 8 Maintenance and storage of T ONE Pag 30 USER MANUAL T ONE Medi Medi Pro cod doc MNPG06 03 Q MEDICAL DIVISION Warning the equipment delivers current in excess of 10mA C 0476 Manufactured in compliance with the 93 42 EEC directive concerning medical devices 17 Assistance Every intervention on device must be performed by manufacturer For any assistance intervention contact the National Distributor or the manufacturer at the following address I A C E R S r l Via S Pertini 24 a 30030 Martellago VE Italy Tel 39 0415401356 Fax 39 0415402684 www iacer it e iacer iacer it You can get any technical documentation on spare parts but only prior business authorization USER MANUAL T ONE Medi Medi Pro MNPG06 03 Pag 31 I A C E R S r l SU Sede operativa 30030 Martellago VE Via S Pertini 24 A Tel 39 041 5401356 Fax 39 041 5402684 Sede legale S Marco 2757 30124 Venezia Cod Fisc P IVA IT 00185480274 R EA VEN 120250 M VE001767 Cap Soc 110 000 00 i v www iacer ve it iacer iacer it
45. se 2 Phase 3 20 min 5 min warm up 6 sec recovery 5 min recovery 7 sec work on CH1 CH2 7 sec work on CH3 CH4 F12 Drain up These programs have specific draining purpouse increasing the microcirculation inside and around treatened muscular fibers also creating rhythmic contractions to facilitate the flow of algogene substances and lymphatic activity This program can be useful for elderly people to aid blood circulation and lymphatic circulation On phase 2 and 3 the programs produce sequential tonic contractions able to produce the typical effect of electronic lymphatic massage However unlike of lipolysis program in drain up program the contraction are sequential start on CH1 then CH2 CH3 CH4 There are no real applicative limits for the use of these programs so they can be used till the achievement of desired result The intensity of stimulation has to be strong enough to assure good muscular contractions during treatment but not so strong to generate stiffness 20 30mA Normally the results appear after 3 4 weeks with 4 5 treatment a week F12 Drain up Program duration 25 minutes Muscles all the muscles you want to stimulate in a sequence of 4 channel Phase 1 Phase 2 Phase 3 Phase 4 10 min sequential 10 min sequential 3 min warm up contractions on 4 contractions on 4 2 min recovery channels 6 sec duration channels 6 sec duration each each F13 Microlifting The f
46. stimulate different sized nerve fibres promoting an inhibitory action at spinal level The intensity should be adjusted to a level between the thresholds of perception and pain without causing muscle contraction Position of electrodes form a square above the area to be treated as shown in illustration 1 T13 Hand and wrist pain Program duration 40 minutes Electrodes positioning wrist photo 33 Phase 1 Phase 2 Phase 3 Tens 70Hz 15 min Tens 90Hz 15 min Tens 110Hz 10 min T14 Plantar stimulation This program has a relaxing and draining effect on the limb stimulated It is ideal for people suffering from a sense of heaviness in the legs Duration 40 minutes Intensity just above the threshold of perception Position of electrodes 2 electrodes one positive the other negative on the sole of the foot one close to the toes the other under the heel T14 Plantar stimulation Program duration 40 minutes Phase 1 Phase 2 Phase 3 Tens 70Hz 15 min Tens 2Hz 15 min Tens 90Hz 10 min T15 Epicondylitis Medical program Also known as tennis elbow it is an insertional tendinopathy concerning insertion of the elbow bone into the epicondylar muscles those enabling finger and wrist extension bending backwards 15 applications once a day even twice until the symptoms pass We recommend that you consult your doctor to identify the precise cause of the pain in order to prevent the conditio
47. timulator 4 connection cables for the transmission of electric impulses 2 packages containing 4 pre gelled self adhesive 48x48 mm electrodes 2 packages containing 4 pre gelled self adhesive 50x90 mm electrodes 1 packages containing 8 round pre gelled self adhesive 32 mm diameter 1 battery charger 4 rechargeable Ni Mh batteries AA 8 for model MEDI PRO 1 T ONE user manual 1 electrode position manual 1 lonophoresis Kit 1 carry bag Spare parts available e Pre gelled self adhesive electrodes 48x48mm 50x90mm round 32mm e lonophoresis pads 60x80mm 80x120mm e Elastic band for lonophoresis treatment 80 mm high code FI80X60 e Set elastic band for legs drainage codes FC250 265 and FP235 245 2 Purpose The T ONE electronic stimulator is a medical device specifically intended for adults with adequate knowledge of the device acquired from reading the manual for domestic use T ONE is used to apply electrical microimpulses capable of producing energy to the human body This energy modulated in accordance with parameters typical to each impulse can be used for various purposes from pain reduction to winding down exercises from muscle strengthening to drainage from isotonic exercises to treating haematomas to the treatment of imperfections using the beauty programs We recommend to consult your doctor before using TENS and REHAB programs Contraindications This device must not be used by people with a pace maker
48. you understand how the machine works 4 during the program and over the next few days the intensity should be increased gradually so that muscle contractions are not painful 5 during machine contractions contract the muscle voluntarily 6 a cycle of 15 20 applications must be completed before the first results can be seen one application for each muscle every two days with a day of rest in between It is possible to work on pairs of muscles for example thighs and abdominal muscles treating one set one day and the other the next day Working on too many muscles at the same time is not recommended A bit at a time but consistently F01 Firming up Program duration 30 minutes Biceps photo 02 15 Triceps photo 03 16 Extensors photo 04 Flexors photo 05 Deltoid photo 06 Abdominals photo 01 20 Pectoral Breast photo 07 17 Trapezius photo 08 Large dorsal photo 09 Gluteus photo 19 Obliques photo 22 We ae ee ae ff ti Quadriceps photo 11 18 Biceps femoris photo12 Calves photo13 Anterior tibial photo14 Phase 1 Phase 2 Phase 3 Phase 4 10 min 10 min 5 min warm up 13 sec recovery 13 sec recovery 5 min recovery 7 sec work 7 sec work USER MANUAL T ONE Medi Medi Pro MNPG06 03 Pag 21 MEDICAL DIVISION F02 Toning up Indicated for toning up muscles in the arms and bust or the legs working mainly on fast twitch fibres Suitable for people who already practice m