VK-300x Manual - Balanced Audio Technology

image

Contents

1. An RB NOW O0WmONNNNN 11 11 12 13 13 13 14 14 15 16 16 16 16 17 17 17 17 17 18 10 INTRODUCTION Thank you for your purchase of the Balanced Audio Technology VK 300X Integrated Amplifier Please read this owner s manual to obtain the full benefit of the VK 300X in your system It will provide you with the needed safety information and operating procedures for this exceptional unit WARNINGS To prevent the possibility of serious injury electrical shock or fire DO NOT operate with the cover removed DO NOT expose to rain or moisture DO NOT defeat the ground power plug DO NOT replace fuse with anything other than the same type and rating as supplied by the factory Package Contents Included in the box should be the following Description Quantity VK 300X Integrated Amplifier 1 Power Cord 1 Spare Fuse 1 Torx Wrench T 10 1 Spare Top Cover Screws 5 User s Manual 1 VK R3 Remote Control If ordered Save all the packaging material in a safe dry area for the unlikely event that you need to return the VK 300X to the factory for service PHYSICAL PLACEMENT It is recommended that you provide at least 6 of free space around the unit for proper ventilation Mount the unit on a hard surface with proper ventilation underneath Do not stack the VK 300X Integrated Amplifier on top of other units nor vice versa CONNECTING THE VK 300X TO YOUR SYSTEM Balanced Components Use balance
2. holding the Function button will store this adjustment for the selected input The BALANCE adjustment for each selected input is also stored when switching to another input while still in the BALANCE programming mode 11 RELATIVE Volume adjustment It is quite common to have sources with very different output levels connected to a Integrated Amplifier In this case switching between different inputs is usually accomplished by a large change in volume The VK 300X allows the user to avoid this inconvenience by setting volume offsets between different inputs using ANY input as a reference To program this feature 1 Select any input that you would like to use as a reference Play music at the level you find comfortable 2 Press the Function button twice The display willread VOL 000 3 Switch to a different input Adjust the volume while playing the music to the level that is comparable to the reference input level The display will indicate the volume offset number That number can be either positive or negative depending upon whether the new selected input is stronger or weaker than the reference input 4 Exit the programming mode by pressing and holding the Function button or by switching to a different input Any input volume offset can be programmed at ANY time with respect to ANY other input EXAMPLE The CD1 input is used as the reference Let s presume that the PH1 input the weaker source is then programmed
3. indicates whether the unit is in its INVERTING or NONINVERTING mode This function is also accessible via the VK R3 remote control LED OFF Non Inverting operation LED ON Inverting operation MONO Button and LED The Mono button allows the user to switch the VK 300X in Mono operation when the two channels are summed together This may be useful for example while listening to old monophonic recordings This function is also accessible via the VK R3 remote control LED OFF Stereo operation LED ON Mono operation MUTE Button and LED The Mute button disables the Integrated Amplifier output It is recommended that the Mute be engaged any time the signal cables are changed or any other system configuration changes are being made This function is also accessible via the VK R3 remote control LED OFF Unit in Play mode LED ON Output Muted INPUT selection buttons 1 through 5 These allow the user to select any of five available inputs to be played The selected input number together with its name will be indicated on the unit front panel display as well This function is also accessible via the VK R3 remote control VOLUME Up and Down Buttons These buttons performs different function depending upon the unit s mode of operation In normal mode they works as volume controls They are also used as a data input device in various Function modes to program the unit For example they are used to set the BALANCE adjustment when the VK 300X is switche
4. is issued To EXIT the programming mode at any time press and hold the Function button for about TWO seconds DISPLAY ON OFF Function Turning the display OFF The VK 300X display can be turned OFF or ON at any time by simply pressing the DISPLAY button on your VK R3 remote control transmitter With the display OFF issuing any remote control command that would normally require a display change i e Volume Input selection Fade will automatically turn the display back ON MUTE Function The VK 300X has two mute modes manual and automatic The blue LED above the Mute button goes ON when the unit is in MUTE state To MUTE the VK 300X depress the MUTE button located on the right side of the front panel Depressing this button again will return the unit to its normal operation and turn the mute LED off When the unit is powered up it automatically self mutes until the proper operating points of the circuitry are reached It will then automatically go into Play mode provided the Mute function was not activated the blue Mute LED is Off Turning the VK 300X OFF even for short time will make the unit reset its power sequencing circuit and mute its output Jt will then require 50 seconds for the unit to become operational again VK 300X PROGRAMING FUNCTIONS The VK 300X programming functions allow the user to optimize the unit configuration for any particular system set up The flexible programming facility defines each signal input wi
5. 7_ c A T Balanced Audio Technology VK 300X WARRANTY REGISTRATION FORM Unit Serial Number Customer Name Address Date of Purchase Purchased From Dealer Name Address IMPORTANT NOTE In order to receive the full five year product warranty please mail this completed form together with a copy of your sales receipt to Balanced Audio Technology at the address below within thirty days of purchase Failure to do so will result in the product being warrantied for one year from the date of manufacture 1300 First State Blvd Suite A Wilmington DE 19804 Tel 302 999 8855 Fax 302 999 8818 p_i T Balanced Audio Technology VK 300X Balanced Integrated Amplifier Owner s Manual 1300 First State Blvd Suite A Wilmington DE 19804 Tel 302 999 8855 Fax 302 999 8818 TABLE OF CONTENT INTRODUCTION Package Content Physical Placement Connecting to your system FRONT PANEL CONTROLS VK 300X Power On sequence Turning the VK 300X Off PHASE Button and LED MONO button and LED MUTE button and LED INPUT selection VOLUME buttons DISPLAY format FUCTION button DISPLAY ON OFF function MUTE function VK 300X PROGRAMMABLE FUNCTIONS Parameter Definitions PROGRAMMING THE VK 300X BALANCE adjustment VOLUME offsets PHASE MONO STEREO MAXIMUM gain FIXED gain DISPLAY MODE INPUT NAME REMOTE CONTROL FUNCTIONS Volume Up Down Mute Fade Input Display Power Fuse Protection Servicing Cleaning Warranty
6. Please direct any further service inquiries to the factory Cleaning To remove dust occasionally wipe the front and top surfaces of your VK 300X with a damp soft cloth If fingerprints appear you may use a mild non alkaline soap solution Do not use abrasive cleaners as they may damage the fine finish of the unit 17 Five Year Limited Warranty Terms and Conditions 1 Limited Warranty Upon receipt of the attached warranty registration form Balanced Audio Technology warrants the purchased product to be free from manufacturing materials and workmanship defects for five years from date of original purchase excepting vacuum tubes subject to the following conditions Failure to return the enclosed registration form within 30 days from original purchase will result in a warranty period of one year from the date of manufacture 2 Limited to Original Purchaser This warranty is for the sole benefit of the original purchaser of the covered product and may not be transferred to a subsequent purchaser of the product 3 Conditions and Limitations This warranty is subject to certain conditions and limitations as follows This warranty is void and inapplicable if the product has not been used in accordance with the instructions found elsewhere in this manual or if it has been misused or abused damaged by accident or neglect or in transport once in possession of the purchaser The warranty is also void if the product has been repaired modi
7. d XLR interconnects All input and output connectors are clearly marked on the back panel Note The VK 300X XLR connectors are wired as follows Pin 1 common shield Pin 2 positive Pin 3 negative Single Ended Components Single ended components have RCA connectors The VK 300X Integrated Amplifier is designed to work with a mix of single ended and balanced components connected to its inputs and outputs If more RCA inputs or outputs are required then the use of Balanced to RCA adapters is recommended These adapters are available from an authorized Balanced Audio Technology dealer at a nominal charge Two types of adapters are available Input Adapters RCA Female to XLR Male Output Adapters RCA Female to XLR Female Preamplifier Output These outputs can be used to connect the external power amplifier to the VK 300x VK 300X FRONT PANEL CONTROLS STANDBY Button and LED The Standby button is used to turn the unit ON and OFF and to switch the Integrated Amplifier into its Standby mode The LED indicates the status of the unit s power circuitry and has four state LED OFF Display OFF Unit is in OFF state Display ON Unit is in ON state LED Flashing Unit is going through its Power ON routine LED ON Unit is in its STANDBY mode When the unit is plugged into a power line it will stay in the OFF state until the Standby button is pushed The LED will then start blinking and the unit will go through a 50second warm up sequence A
8. d into its Balance mode More on that in the corresponding sections of this manual DISPLAY FORMAT The VK 300X Vacuum Fluorescent Display VFD is capable of showing up to twelve alphanumeric characters Its format depends on the mode of operation In the normal PLAY mode the display has the following format 1 One character indicating the selected input number 2 Four character input name That name is fully programmable See the programming functions and can include up to four character from the Latin Cyrillic or Greek alphabets or digits 3 Balance adjustment indicator Characters L or R indicate that the balance is shifted in the corresponding direction A BLANK character means that the gains of both channels are identical 4 Volume setting three digits with the full range of 000 to 140 See programming section on Maximum Volume Setting FUNCTION Button This button puts the unit in its programming mode In addition to its normal PLAY mode there are eight programmable functions in the VK 300X BALANCE Adjustment RELATIVE VOLUME setting PHASE setting MONO STEREO setting MAXIMUM volume setting FIXED volume setting DISPLAY Volume mode INPUT NAME assignment Pressing this button while in PLAY mode will switch the unit into programming mode Once in the programming mode pressing the Function button will switch the unit into its NEXT programmable functions The unit will stay in the programming mode until the exit command
9. fied or tampered with by anyone other than Balanced Audio Technology or its specifically authorized agents 4 Remedy If this product contains a materials manufacturing or workmanship defect that cannot be repaired at the dealership where the product was purchased it must be packed in original packaging and returned to Balanced Audio Technology via insured freight at the owners expense If replacement packaging materials are required they will be supplied by the factory at a nominal charge Returned products must be accompanied by a written description of the defect and a return authorization number available from the factory via phone or fax Upon receipt of defective product Balanced Audio Technology agrees to repair the product without charge for parts except vacuum tubes if the unit is more than one year old or labor The product will then be returned via prepaid insured freight with carrier at the sole determination of Balanced Audio Technology This constitutes the purchasers sole remedy 5 Design Changes Balanced Audio Technology reserves the right to modify its products or change specifications at any time without obligation or liability to previous purchasers 6 Miscellaneous Any implied warranties relating to the above product shall be limited to the duration of this warranty This watranty does not extend to any incidental or consequential costs or damages to the purchaser This warranty gives you specific legal rights Yo
10. lifier correspond to the following volume setting CNTS display mode 100 Counts DBU 00 0dB DBM 20 0dB Exit the programming mode by pressing and holding the Function button DISPLAY MODE programming The volume display of the VK 300X can be switched to work in any of the following three modes CNTS Relative volume counts with the range of 000 to 140 DBU Decibel readings with respect to unity gain OdB DBM Decibel readings with respect to maximum gain 20dB NOTE To avoid possible confusion the SAME display mode setting applies to ALL inputs It is not possible for example to set one input to CNTS and another to DBU 14 INPUT NAME programming The VK 300X allows the user to assign any a custom name to any input Those names may include up to four characters The default names for the inputs are as follows 1 TAPE 2 TUN 3 CDI 4 AUX1 5 AUX2 Any combination of up to four Latin Cyrillic Greek alphabet characters or digits can be used to name the source The examples may include CD 2 DVD1 JOHN VKD5 MARY BOBI etc To program the input name do the following Select the desired input Press the Function button eight times The first character of the input name will start blinking Use the front panel volume control buttons or the remote control Volume Up Down buttons to select the desired character The characters are organized in the following order the digits the Latin alphabet the Cyrillic Rus
11. nit in Mute Pressing the Fade button again will cause the volume to ramp back up to its initial value 16 INPUT SELECT Pressing any input selection button on the VK R3 remote control will switch the VK 300X to that input All of the set parameters associated with that input would be loaded at this point DISPLAY POWER switch The Display Power button on the VK R3 remote control provides two functions turning the VK 300X display ON OFF and switching the power to the Integrated Amplifier To control the display Pressing the display button will switch the display from ON to OFF and back Turning the VK 300X OFF With the display in ON state press and hold the Display button on the VK R3 remote control This function is disabled when the unit s display is turned OFF Turning the VK 300X ON With the VK 300X in its OFF or STANDBY state simply press the POWER button on the VK R3 remote control transmitter Fuse Protection A blown fuse in the VK 300X is an indication of a serious problem If a replacement fuse fails as well no further attempts should be undertaken Please contact the factory for professional service The proper fuse ratings are as follows For 100 120 VAC Units 5A 250V Slow Blow For 200 240 VAC Units 2 8A 250V Slow Blow Factory supplied fuses should be only replaced with the same type and rating parts Servicing The Balanced Audio Technology VK 300X should require no service in normal operation
12. sian alphabet the Greek alphabet Advance to the next character by pressing the Function button once Exit the programming mode by pressing and holding the Function button 15 REMOTE CONTROL FUNCTIONS The optional VK R3 remote control that comes with your VK 300X has the following functions Volume Up and Volume Down control Mute function Fade Down Fade Up function Input source selection 1 through 5 Phase switch Function switch Display POWER switch The following describes these functions Volume Up and Down These two buttons are programmed with variable speed volume change profiles The rate of volume change will be slow upon initial pressing of the Volume Up or Down buttons Holding the button depressed will cause the rate of change to accelerate allowing for more flexible control when large changes in volume are required Mute Pressing this button will cause the MUTE function in the VK 300X to toggle between ON and OFF states The Mute LED on the VK 300X front panel will reflect the status of the Mute circuit Fade Pressing the FADE button on the VK R3 remote control will cause the volume to smoothly decay over the period of several seconds This allows for a gradual reduction in volume as opposed to the instantaneous MUTE function This can be particularly useful during the presentation or demonstration of your equipment When the FADE button is pressed the volume will go down all the way to zero 000 on display u
13. t the end of that sequence it will turn ON Pressing the button again will switch the unit into its Standby mode The VK 300X can be turned OFF by pressing and holding the Standby button VK 300X Power On sequence When you turn the VK 300X On it will automatically go through a gentle power on sequence This sequence takes 50 seconds during which time the display and the Standby LED will be flashing indicating the status of the unit 1 The number on the display during this time indicates the volume setting This will usually start at 000 This setting can be changed during this time by using the volume knob or Volume Up Down buttons on your VK R3 remote control transmitter In addition such functions as Phase Mono input selection and Mute can be changed during this time either from front panel or through the remote control 2 Normally the VK 300X will be not muted Mute LED on the display is OFF and will begin playing at the end of the 50 second delay If so desired the unit can be put in the MUTE mode during this delay interval either by depressing the front panel MUTE switch or by using the MUTE button on the VK R3 remote control transmitter Turning the VK 300X Off The unit can be turned OFF by pressing and holding the Standby button It will automatically mute PHASE button and LED This button allows the user to invert the absolute polarity of the signal to compensate for some recordings that are made out of phase The LED
14. th a group of user selectable parameters that are then stored in the unit s memory Every time a particular input is selected its unique combination of parameters is loaded into the operating memory Programming is easy and is accomplished through using just two front panel controls the Function button and Volume buttons or corresponding remote control buttons Function and Volume Up Down buttons Every unit comes from the factory with a default set of parameters stored in its memory This set of parameters is usable for many applications The default set includes the following parameters BALANCE RELATIVE VOLUME PHASE MONO STEREO MAXIMUM VOLUME FIXED GAIN DISPLAY INPUT NAMES ZERO ZERO Non Inverting STEREO 140 OFF COUNTS 1 TAPE 2 TUN 3 CD1 4 AUX1 5 AUX2 The user may at any time configure the unit to a particular set of system requirements For example input names can be changed to reflect a given system s source configuration 10 Parameter Definitions Every input of the VK 300X is defined with the following set of parameters 1 Input name Examples include CD1 DVD1 PH 1 VKD5 or any other combination of up to four characters including the Latin Cyrillic and Greek alphabet as well as digits 2 Balance adjustment gain shifted Left or Right 3 Volume offset relative to any other input to compensate for gross differences in various sources levels 4 Phase Inverting Non inver
15. ting or Last configuration 5 Stereo Mono or Last configuration 6 Maximum allowable volume setting for a particular input This is a convenient safety feature in some instances 7 Display mode This allows the user to switch the volume display to operate in any of the three modes relative Counts DBU Decibels referenced to Unity gain or DBM Decibels referenced to Maximum gain 8 Fixed volume mode this allows any input to be set with a preferred fixed volume setting and is usable for example in Audio Video installations With this flexibility it is possible for example to set the CD input to be Stereo and Non Inverting while the PHONO input would be Mono and Inverting PROGRAMMING THE VK 300X NOTE It is important to note here that all the functions described below are accessible either through the front panel controls or via the VK R3 remote control Therefore functions like BALANCE PHASE MONO etc all can be performed by using the Function button on the remote control in conjunction with the Volume Up Down buttons BALANCE Adjustment Pressing the Function button once will invoke the Balance adjustment mode When in this mode use the front panel Volume buttons or press the Volume Up Down buttons on the VK R3 remote control to set the balance to the desired position An L or R character will appear indicating that the balance is now shifted in the corresponding direction Exiting the programming mode by pressing and
16. tion button NOTE In the LAST mode the state of the PHASE switch will be the same as used the last time for that particular input MONO STEREO programming Select the desired input Press the Function button four times The display will read STEREO Use the volume buttons to set the condition to STEREO MONO or LAST Exit the programming mode by pressing and holding the Function button NOTE In the LAST mode the state of the Phase switch will be the same as used the last time for that particular input MAXIMUM gain programming It may be desirable to limit the allowable volume setting on a particular input To do this Select the desired input Enter the MAXIMUM programming mode by pressing the Function button five times Set the display to any desired number that will now represent the maximum allowable volume setting for the selected input Exit the programming mode by pressing and holding the Function button 13 FIXED Gain mode In some systems some A V installations for example it is desirable to set a particular input to a fixed gain that is then becomes unaffected by the volume knob Most often it is required to set the Integrated Amplifier gain to Unity Gain of 1 The VK 300X allows the user to do so by using its FIXED gain function Press the Function button six times The display will read FIX OFF Enter any desired number for the fixed gain on the selected input see below UNITY gain for the VK 300X Integrated Amp
17. to play at 20 counts higher Its volume offset will then read 20 The user can later select the PH1 input and using it as the reference program the AUX1 input to be 10 counts lower than the PH1 input Effectively the volume offset from the CD1 input to the AUX1 will now become 10 The user then can at any time verify his volume offset programming by switching the unit in its VOLUME mode by pressing the Function button twice and then selecting the inputs 3 4 and 5 The volume offset numbers for these inputs should then read 0 10 and 20 respectfully That means that the AUX1 source will be played at 10 counts above the CD1 input and the PH1 input at 20 counts above the CD1 input Alternatively the volume offset number can be entered directly based on your judgement of volume difference between the two sources To do that select the input enter the VOLUME programming mode by pressing the Function button twice and use the volume knob to set the volume offset number that you deem desirable Then exit the programming mode by pressing and holding the Function Button NOTE A negative number for the selected input indicates that its gain will be set lower than the gain of the reference input 12 PHASE programming Select the desired input Press the Function button three times The display will read PHASE NINV Use the volume buttons to set the condition to NINV INV or LAST Exit the programming mode by pressing and holding the Func
18. u may also have other rights which vary from state to state 18

Download Pdf Manuals

image

Related Search

Related Contents

Contrato de condiciones generales de uso para la  EVGA 01G-P3-1468-KR NVIDIA GeForce GTX 560 1GB graphics card  User's Guide Test Monitor Features  Manuel d`Installation  ici-même  NAMCO Bandai Games 90500129 User's Manual  CAPITOLATO SPECIALE D`APPALTO  GE JN327HCC 30" Standard Range Hood: Bisque on Bisque  DJ Lase 150-R MK-III showlaser user manual  