Home

E and ES Series Enclosures Installation Instructions

image

Contents

1. Each ladder rack bracket part number is a single ladder rack bracket with installation hardware two brackets are required per enclosure Once two brackets are installed ladder rack can be attached Height adjustable brackets can be used when different height enclosures require ladder rack across them Fixed height brackets can be used when all enclosures in a row are the same height detail shows fixed height bracket installed Available ladder rack brackets include LRB 12A1 Single Height Adjustable Bracket 6 5 11 5 to support 12 W ladder rack LRB 12A2 Single Height Adjustable Bracket 14 24 to support 12 W ladder rack LRB 24A1 Single Height Adjustable Bracket 6 5 11 5 to support 12 24 W ladder rack LRB 24A2 Single Height Adjustable Bracket 14 24 to support 12 24 W ladder rack LRB 12 Single Fixed Height Bracket 3 to support 12 W ladder rack LRB 24 Single Fixed Height Bracket 3 16 to support 12 24 W ladder rack we mM 5 16 18 x 3 CS 7 a Bolt Ladder uo 1 Brackets MW d a gt gt a 5 16 18 E LE A Flat Washer Ca a 5 16 18 Hex Nut 5 16 18 Flat Bolt 5 16 18 Flat Washer 5 16 18 Hex Nut LADDER RACK ATTACHMENT Em HOLES E SERIES NN All E Series tops have pre drilled cable runway attachment holes T LA EN EXTERNAL CABLE MANAGER SIDE CAR ES SERIES The side car is an external cable manage
2. CL Counter clockwise rotation will adjust the leveling glide up Clockwise rotation will adjust 75 Thru holes the leveling glide down Y CASTER AND LEVELER MOUNTING ES SERIES 2 4 D 4 Adjustable Levelers 5 16 18 Hex Nuts gt A Counter clockwise rotation will AUTION To install casters or levelers the enclosure must be tipped onto its side The enclosure can be very heavy several people will be required in this process Please practice safe lifting techniques DO NOT lay the enclosure on its front or back this may damage the door hinges Removing doors and sides will help reduce the weight of the enclosure Before tipping remove the side panels to prevent damage to the locks and latches To install casters the enclosure must first be tipped over onto laid on its side Pass a plate caster over four threaded studs located in one of the recessed areas in the bottom of the enclosure Thread 1 5 16 18 hex nut onto each stud and tighten with a 1 2 socket or nut driver Repeat steps 2 and 3 for the three remaining casters Install leveling glides 7209 N at this time if they were ordered with the enclosure 4 1 2 13 Threaded Holes A adjust the leveling glide up Clockwise rotation will adjust the leveling glide down 5 Thru Holes 6 Total TOP PANEL MOUNTING ES Enclosure The top panel of the enclosure is installed at th
3. P IL BI Vertical Brush Strip Mtg Plates M less Hardware ld Push Pull Nylon Rivet Brush Strips Flexible PVC Slides Onto Outside Edge of Mounting Plates Mount 1 4 Thru Holes that are Installed Onto Front on Front Face of Rails Face of the Equipment Rails 21 BAFFLE KITS Baffle Kits can be installed in ES Enclosures and Great Lakes EN Enclosures visit werackyourworld com for installation instructions While this user s manual is specific to ES E enclosures please note that the chart and following information also references EN Enclosures Baffle Kits create proper airflow for switches and side to side airflow equipment as suggested by manufacturers such as CISCO Cool air is channeled into the equipment along the right side and exhaust air is directed out along the left side of the equipment Kits are tool less and easily attach to rails outside of the EIA mounting profile Kits available for 25 19 14 and 11 RMU equipment are unique to ES and EN enclosures creating the perfect fit between switch and enclosure Great Lakes Great Lakes Enclosure Baffle Kit Part No EN Series ES Series EN ES Enclosure Enclosure Baffle Kit Baffle Kit 7000 Series 7018 8401EN 4048 ENSAB25 N A 7009 8401EN 4048 ENSAB14A N A 9513 8401EN 3242 XX01ES 30XX ENSAB14D ESSAB14D 9509 8401EN 3242 XX01ES 30XX ENSAB14 ESSA
4. WARNING To avoid injury to persons or loss of life ground each enclosure individually to the dedicated branch circuit ground Connecting Main Protective Grounding Stud to the Dedicated Branch Circuit Ground Connect the dedicated branch circuit ground connector to the main protective grounding stud located inside at the bottom rear of the enclosure frame using a listed ring or closed loop terminal Connecting Main Protective Grounding Stud to the Protective Bonding Conductors Connect the rear doors to the main protective grounding studs located inside at the bottom and top rear of the enclosure chassis using a listed ring or closed loop terminal Connect the front door to the grounding stud located inside at the bottom front of the enclosure frame using a listed ring or closed loop terminal Parts Not Bonded to Protective Earthing Terminal The following parts are not effectively bonded to the protective earthing terminal rails and front to back rail horizontals If these parts need to be bonded to the protective earthing terminal do so in accordance with Article 250 of the National Electric Code ACCESSORIES STATIONARY SHELVES 19 Rack Mount PART NO WIDTH DEPTH MAX TAB PMT WT CAP 7206 FM 17 25 18 00 60 165 7206 ElA 17 46 18 00 80 165 7206 FR AHD 17 50 22 25 26 125 200 Ibs 7206 FR ADHD 17 50 27 25 32 250 150 Ibs 7206 FR A28HD 17 50 28 00 30 180 300 Ibs 7206 FR A32HD 17 50 32 00 36 000 300 Ibs 72
5. AN H AN FX at N N XN NN XN A VN M a waso M 7 r 4 Fi WAY N J f fof A NS X 9 V ANN VA V v f ff 7 NN IN NBN eet y 7 4 CRI Y ee UH x NN ADJ USTABLE LEVELER MOUNTING E SERIES On the bottom of the cabinet there are eight threaded holes two in each corner The outside holes are threaded 1 2 13 thds and will accept the levelers Once the levelers 7209 N or 7209 N4 are installed the cabinet level can be adjusted with the use of a 3 4 open end wrench or a 5 16 closed wrench from inside of the enclosure ANCHOR MOUNTING THRU HOLE E SERIES The middle 75 dia thru holes are for securing the enclosure to the floor These holes will accept a standard concrete anchor if desired the Seismic Anchor Kit AK101 is suggested CASTER MOUNTING E SERIES The four inside holes in each corner are threaded 1 2 13 thds to accept the casters Be sure to thread the caster into the bottom of the cabinet until it is firmly seated 4 Adjustable UN Swivel Casters 20 II IO i P P d P d d d d d d lt
6. a sufficient number of service personnel Do not attempt to move enclosures by yourself Only UL Listed ITE Information Technology Equipment units should be installed inside the E and ES Enclosure Be sure to read and follow all individual manufacturer equipment manuals for safety and installation instructions Proper spacing is required when installing electrical equipment to avoid electrical shock Maintain minimum spacing between the accessories and components and the computer enclosure assembly for safe operation of the equipment when installed in accordance with the National Electric Code ANSI NFPA 70 1999 The ambient temperature operating range for the E and ES Enclosure and accessories is 50 to 95 F 10 to 35 C The non operating temperature is 4 to 140 F 20 to 60 C 2 SERVICE The E and ES Enclosures should be repaired by personnel trained by Great Lakes or returned to Great Lakes for repair or replacement Contact Great Lakes Technical Support at 814 734 7303 or at werackyourworld com WHAT S INCLUDED e Eor ES unit assembled e Keys as needed depending on configuration e 50 M6 cage nuts 3 8 square and screws 10 32 tapped rails available must be specified at time of order This user s manual This user s manual applies to the following Great Lakes enclosures Part No H W D RMU GL720E 2432 72 24 32 37 GL720E 2436 72 24 36 37 GL720E 2932 72 29 32 37 GL720E 2936 72 29 36
7. of Chimney Notches Should Fall Onto ge Studs in Chimney 10 32 x 1 2 L Mounting Screws p VV 2 K Qty 4 RET IN n S Le Install Nuts Onto Studs Mounting Holes from Bottom Inside For 10 32 E Enclosure Qty 4 Screws Qty 4 Use Screwdriver to Punch Out Rear Knockout 20 MESH CONTOUR DOOR ES SERIES The mesh contour door for the 24 W enclosures will accept a two 2 hole fan assembly 7217LE2 The mesh contour door for the 30 and 29 W enclosures will accept a three 3 hole fan assembly ai 72171 Both of these fan assemblies on simply need to be attached to the door using the supplied 10 32 hardware The fans should be placed where you need to alleviate a hot spot Adjustable 4 Increments BRUSH GROMMET KIT ES SERIES The brush grommet kit is best installed before any equipment is installed in the enclosure Please refer to detail A for mounting and hardware usage BGRK24 is for use with 24 W ES enclosures while the BGRK30 is for use with 30 W ES enclosures 19 EIA Equipment Mtg Brush Strips Flexible PVC Trim Slides Rails Shown for reference Onto Outside Edge of Mounting Plates Included with Enclosure that are Installed Onto Front Equipment Face of the Equipment Rails Mtg Rails Top Cross Shown for Plate V Include with Enclosure NS N gt De i M I F at 9 2 IT Ba Tho
8. when placing your PDUs Y Figure k ER TOOLLESS MOUNTING d M ER li PI N gt 140 32 TAPPED v f iu Yo Il PM o o sy yY DN k r 1 22 li IR T y E M A Y Figure alien H Ly vt P EE i Y 10 000000 n ATI J n LY 3 af li j 3 00 2 19 2 19 Detail F Fi Figure C yl Fil pu xi Pfad Fl oth i BPR CW Figure D Hy hil j v 1 22 At LEX SS nM EON 7 T lt 24 ay 2 64 Ps 2 19 POWER When using power distribution units PDUs each PDU should be connected to a committed branch circuit that is rated for the continuous load of all the equipment connected When not using a PDU each piece of equipment should be connected to a dedicated branch circuit 13 PLASTIC CABLE MANAGEMENT FINGERS ES SERIES The CM 47 is a single section of 7 RMU fingers that mounts to the Flexible Mounting Profile FMP of enclosure rails The ESC K12 is a kit of 12 sections and the ENC K24 is a installed on the front or rear rails but kit of 24 sections Fingers can be front rails must be recesse
9. 0 60 1200 NOTE It is important to read and understand CISCO installation guides that are associated with each switch 23 NETWORKING GANGING Enclosures can be networked using the following networking ganging kits G101 Networking Ganging Kit to gang two E Enclosures pictured no tools required G101ES Networking Ganging Kit to gang two ES Enclosures G101EN2ES Networking Ganging Kit to gang an EN Enclosure to an ES Enclosures Washer Washer Lock Washer S yt Wing Thumb Nut Screws GROUNDING 410 32 Keps Nut GROUNDING KIT GR101 8 Grounding studs in our E and ES Series enclosures provide a point to which the doors Ground Wire T may be grounded to the enclosure and from Washer which the enclosure may be connected to the Ground Stud facility s common ground The studs are made 10 32 1 7 8 LG from copper which is a conducting metal E 50mm LG Enclosures have three ground studs in the Quick Disconnect frame two in top and one in the bottom ES Enclosures have two ground studs in the Ground Wire bottom rear of the frame Assembly This kit allows you to ground the enclosure so th
10. 0 32 x 1 2 Clip w Lock Washer Flat Head Screw Pan Head Screw PSBKE 2 2 10 10 10 10 To mount Universal Power Strip Brackets enclosure or cabinet extension measure the required mounting distance top to bottom install brackets then install power strip 10 32 Nut with lt AAN Lock Washer gt pu gt A L P lt 6 J 27 77 amp c 10 ae 10 32 x 1 2 r Pan 10 32 x 1 2 Tinnerman Clips Lock Washer Pan Head Screw Optional MOUNTING IN A CABINET EXTENSION 810 32 Nut with Lock Washer 10 32 x 3 8 10 32 x 1 2 Flat Head Screw Pan Head Screw 12 OPTIONAL ACCESSORIES VERTICAL CABLE TROUGH amp PDU MOUNTING ES SERIES For GL780ES GL840ES The ES enclosures come with a universal power strip bracket set in both rear corners These bracket sets will accept a wide range of Power Distribution Units PDUs and will also accept vertical cable troughs The VCT 78 and VCT 84 3 W x 2 572 D are ES enclosure vertical cable troughs Figures A B C amp D show the bracket and the usable mounting space in 42 D enclosures brackets in 48 D enclosures not pictured have six sets of holes The size of the PDU will determine how many of them you will be able to place on the brackets Keep in mind the VCT are 3 W The location of the button mounting will also need to be taken into consideration
11. 06 BT 17 00 20 75 25 250 300 Ibs SLIDING SHELVES 19 Rack Mount PART NO WIDTH DEPTH MAX TAB PMT WT CAP 7206 FRSL AHD 17 50 22 00 26 125 110 Ibs 7206 FRSL ADHD 17 50 26 00 32 125 110 Ibs 7206 FRSLA300 14 33 30 00 36 12 300 Ibs 7206 SL 16 34 17 50 40 Ibs 7206 DR 16 00 18 875 25 500 100 Ibs SPECIALTY SHELVES 19 Rack Mount PART NO WIDTH DEPTH MAX TAB PMT WT CAP 7206 MKM 17 00 24 00 36 12 200 Ibs 7206 PKB MT 20 62 9 50 36 12 N A VERTICAL POWER STRIPS PART NO OUTLETS LENGTH FEATURES 7215 16 49 Circuit Breaker 5 15P Plug 5 15R Receptacle 7215 S 16 49 Surge Suppressor C B 5 15P Plug 5 15R Receptacle 7215 ARTLP 16 49 C B Twist Lock Plug L5 20P 5 20R Receptacle 7215 20 16 49 Circuit Breaker 5 20P Plug 5 20R Receptacle 7215 30A 24 48 Two banks of 12 NEMA 5 20R Receptacles L5 30P Plug 7218 24 8 25 Circuit Breaker 5 15P Plug 5 15R Receptacle for use with 48 and 60 H enclosures Measure your vertical EIA rails front to back for shelf compatibility Shelf mounting tabs are adjust able beyond the shelf surface depth for maximum flexibility Visit our web site at www werackyourworld com for a complete list of available accessories NOT RESPONSIBLE FOR TYPOGRAPHICAL ERRORS 26 CONFIGURED ENCLOSURES ANY WAY YOU WANG SHIPPED UJIEHI 24 48 HOURS READY CHOOSE A STANDARD ENCLOSURE PICK THE GREAT LAKES ACCESSORIES YOU NEED SET WE LL CONFIGURE THE ENCLOSUR
12. 37 GL840E 2432 84 24 32 44 GL840E 2436 84 24 36 44 GL840E 2932 84 29 32 44 GL840E 2936 84 29 36 44 GL480ES 2442 48 24 42 24 GL780ES 2442 78 24 42 42 GL780ES 3042 78 30 42 42 GL840ES 2442 84 24 42 44 GL840ES 3042 84 30 42 44 GL840ES 2448 84 24 48 44 GL840ES 3048 84 30 48 44 ES weight capacity 2000 Ibs E weight capacity 1500 Ibs INSTALLATION Receiving Unpacking and Removing the E or ES Enclosure from the Pallet Inspect and report any damage before receiving Unpack the enclosure by carefully removing the corrugated carton and corners Avoid damaging the enclosure when removing packaging WARNING Only trained service personnel should be used to remove the enclosure from the pallet Also be sure you have a sufficient number of service personnel Do not attempt to move enclosures by yourself WARNING Be careful when moving enclosures before installation Sudden stops and starts excessive force obstructed routes and uneven floor surfaces may cause the enclosure to topple over Loading Equipment WARNING Only install equipment after the E and ES Enclosure has been properly secured Do not move the E and ES Enclosure assembly while loaded Once in place at the desired intended location deploy the leveling feet for maximum stability Rated or maximum load capacity for the E and ES Enclosure is 1500 and 2000 pounds respectively on the floor or on leveling glides To maintain a uniform distribution of the mechanica
13. ALLATION OF ADJUSTABLE EXHAUST CHIMNEY Before installation remove the rear top knockout from the enclosure Place assembled chimney on top and attach from the inside using 10 32 screws Raise the outer section so the seal touches the ceiling INSTALLATION OF FAN TRAY Place fan tray onto fixed portion of the chimney ensuring cord is hanging through the chimney and into the enclosure The fan will rest on four studs Secure the fan with 10 32 nuts from the inside of the enclosure Available Chimney and Fan Trays include GL ECHF 48 1832 High Flow Chimney for 48 D enclosure with an adjustable range of 18 to 32 GL ECHF 48 3246 High Flow Chimney for 48 D enclosure with an adjustable range of 32 to 46 GL ECHFFT48 High Flow Fan Tray for 48 D enclosure 2260 CFM GL EC 48 1832 Chimney for 48 D enclosure with an adjustable range of 18 to 32 GL EC 48 3246 Chimney for 48 D enclosure with an adjustable range of 32 to 46 GL ECFT48 Fan Tray for 48 D enclosure 1200 CFM GL EC 42 1832 Chimney for 42 D enclosure with an adjustable range of 18 to 32 GL EC 42 3246 Chimney for 42 D enclosure with an adjustable range of 32 to 46 GL ECFT42 Fan Tray for 42 D enclosure 1200 CFM Adjust Chimney to Desired Cord for Fan Tray to SK SQ Height Use Screwdriver to Exit back Through WH Punch Out Appropriate the Chimney and i gt Knockout for Knob Qty 2 Both Sides Rear of Enclosure 7 Drop Fan Tray Into Fixed Bottom Portion
14. B14 6000 Series 6513 E 8401EN 3242 XX01ES 30XX ENSAB19 ESSAB19 6509 E 8401EN 3242 XX01ES 30XX ENSAB14 ESSAB14 6506 E 8401EN 3242 XX01ES 30XX ENSAB11 ESSAB11 Four post mounting is required with a rail placement of 24 An additional 0 75 of height is required for rail mount brackets brackets can be removed after chassis is installed 22 CHOOSING YOUR BAFFLE KIT amp ENCLOSURE Based on your switch equipment choose the appropriate EN or ES enclosure Take into consideration your cable management cooling and power needs each enclosure addresses these needs in different ways Baffle Kit part numbers are specific to ES or EN Enclosures The chart below shows which kits accommodate various CISCO switches Other brands of side to side airflow equipment can also be mounted To determine the correct enclosure and baffle kit compare physical equipment dimensions to what is listed For detailed instructions on how to install your baffle kit please refer to the instructions provided with your baffle kit These instructions are also available at werackyourworld com Although equipment may physically fit into a Great Lakes enclosure with or without brackets customers must also review and comply with the equipment manufacturer s installation and other requirements For example the E and ES Series Enclosures when in an open frame configuration can physically support the installation of a Cisco 7018 Series switch however the E an
15. E EXACTLY HOW YOU SPECIFY EVERYTHING IS WRAPPED IN ONE ENCLOSURE GO CONFIGURED ENCLOSURE WILL SHIP WITHIN 24 48 HOURS OF RECEIPT OF ORDER 27 GREAT LAKES CASE amp CABINET NA Invest in Solid Engineering Thank you for your business EE d 1 STEREC 1 nci ISO 9000 2008 Bicsi m me CORPORATI a i ES Sa 5 nica ATE APS Rootes Registrai ISO 9001 2008 Registered ETSI Associate Member FORM MS 5 02 13 REV 6
16. GREAT LAKES A95 CASE amp CABINET Invest in Solid Engineering E and ES Series Enclosures Installation Instructions WeRackYourWorld com 1 866 TRY GLCC 879 4522 Instructions for the following Great Lakes Enclosures GL720E 2432 GL720E 2436 GL720E 2932 GL720E 2936 GL840E 2432 GL840E 2436 GL840E 2932 GL840E 2936 GL480ES 2442 GL780ES 2442 GL780ES 3042 GL840ES 2442 GL840ES 3042 GL840ES 2448 GL840ES 3048 PREFACE This manual is provided to prevent service personnel from committing an act that results in the risk of fire electric shock or injury to persons Only trained service personnel should receive unpack and assemble the E and ES Enclosures In addition only trained service personnel should install equipment in enclosures SAFETY SYMBOLS USED IN THIS MANUAL This manual provides general safety guidelines to be observed during installation operation and maintenance of the E and ES Enclosure WARNING Failure to follow directions in the warning could result in injury to persons or loss of life CAUTION Failure to follow directions in the caution could result in damage to equipment or storage data SAFETY CONSIDERATIONS WARNING Improper handling and use of the E and ES Enclosure could result in equipment damage serious injury or possible death Only trained service personnel should be used to remove the enclosure from the pallet Also be sure you have
17. NTING E SERIES For your convenience we have provided mounting brackets in the left rear and right rear corners of the lt enclosure for mounting power strips vertically Typically any power strip shipped with i an enclosure will be installed at the manufacturer To install a power strip in the field remove the 10 32 x 1 2 lg screws that secure the bracket to the frame Place the power strip into the corner post of the frame and then place one bracket between the top two outlets and install the 10 32 x 1 2 Ig screw into the threaded hole in the frame Then place the other bracket over the power strip between the bottom two outlets and secure to the frame with the DETAIL A same type of screw For ES power strip mounting see page 13 POWER When using power distribution units PDUs each PDU should be connected to a committed branch circuit that is rated for the continuous load of all the equipment connected When not using a PDU each piece of equipment should be connected to a dedicated branch circuit 11 UNIVERSAL POWER STRIP BRACKETS E SERIES Great Lakes offers a universal power strip bracket kit These brackets allow you to mount a PDU with button mounting See drawing PSBKE E Series PDU 10 32 x 10 32 3 8 Flat 1 2 Brackets 10 32 Nut with dm Head PanHead K Waeher Screw Screw 8 PDU Bracket Spring Clip 10 32 Nut 10 32 x 3 8 1
18. acing Bar Kit 48 H x 42 D enclosures VLB 7232 Lacing Bar Kit 72 H x 32 D enclosures VLB 7236 Lacing Bar Kit 72 H x 36 D enclosures VLB 7836 Lacing Bar Kit 78 H x 42 D enclosures VLB 8432 Lacing Bar Kit 84 H x 32 D enclosures VLB 8436 Lacing Bar Kit 84 H x 36 42 and 48 D ane a VLB 72 Vertical Lacing Bar 72 H enclosures VLB 78 Vertical Lacing Bar 78 H enclosures VLB 84 Vertical Lacing 84 H enclosures Detail B HORIZONTAL LACING BARS E AND ES ENCLOSURES Horizontal lacing bars are depth specific Double rows of vertical and horizontal slots allow you to use velcro straps or cable ties to secure your cables which you can run from front to rear of enclosure Available Horizontal Lacing Bars include HLB 32 Horizontal Lacing Bar 32 D enclosures HLB 36 Horizontal Lacing Bar 36 42 amp 48 D enclosures Detail B 15 OVERHEAD CABLE TROUGH ES SERIES When ordered with the enclosure the overhead cable trough ships assembled but not installed When ordered separately the trough will still ship assembled The top of the ES enclosure has a variety of mounting holes Place the trough where you require cable routing For 24 W enclosures use the TCT24 for 30 W enclosures use the TCT30 LADDER RACK BRACKET ES SERIES
19. at it is ready to be connected to the common building ground The kit contains one 48 L ground wire assembly and five 24 L ground wire assemblies Each assembly is made of two smaller wires that are connected this allows a Quick Disconnect when the wire must be removed Using the grounding wires supplied connect one end to the copper ground stud on the side panels and or doors and the other end to the copper ground stud on the enclosure frame Once all wires have been connected to a frame stud have at least one frame stud connected to the common building ground If a ground wire needs to be disconnected e g when the enclosure door needs to be removed but is attached to the enclosure with the ground wire simply pull apart the ground wires 24 COPPER BUS BARS It is important to note that grounding the enclosure does not ground the equipment mounted within it In order for any individual devices and components mounted within an enclosure to be grounded they must be connected to a copper bus bar Available copper bus bars include e CBB 19 Copper Bus Bar for 19 rack mounting Isolated e CBB 48 Copper Bus Bar for 48 H enclosures Isolated e CBB 60 Copper Bus Bar for 72 H enclosures Isolated CBB 72 Copper Bus Bar for 78 and 84 H enclosures Isolated PROTECTIVE GROUNDING Protective grounding studs are provided along with grounding jumper wires that electrically bond the enclosure doors to the enclosure frame
20. d 4 5 for proper installation It is recommended that each CM 47 be installed using 3 points of attachments CTH an ESC K12 Cable Management Rail Kit for 78 or 84 E amp ES Enclosures Front or Rear NM SN A Wo 534 9 amp 2 9 amp 3 amp a 4 sfa 4 aj s 9 5 XA il B A o E 4 ATA VAAN AAN A RAN HCM D36E5 MOUNTING 30 W ES SERIES DETAIL B 14 HCM D36ES are horizontal cable troughs that can be used in the ES enclosures If these parts are ordered with the enclosure they are pre installed If you need to move the trough please do so before ganging enclosures These troughs are installed between the side panel and the 19 rack mount rails Side panel will have to be removed before installation See detail VERTICAL LACING BARS E AND ES ENCLOSURES Vertical lacing bar kits include two horizontal lacing bars and one vertical lacing bar When ordered with an enclosure these kits will come pre installed Lacing bars run independently from 19 rack rails and are infinitely adjustable front to back Additional vertical lacing bars are also available these will only mount when a kit is also installed Available Lacing Bar Kits include VLB 4832 Lacing Bar Kit 48 H x 32 D enclosures VLB 4836 L
21. d ES Series Enclosure frame designs do not provide the airflow space clearance required by Cisco Great Lakes EN Enhanced Networking Series of enclosures is designed to support the installation of Cisco switches and other side to side airflow equipment The EN Series has the airflow space clearances that are currently required and has accessories including baffle kits that are designed to support proper operational conditions For more information please contact your Great Lakes representative or call 1 866 TRY GLCC When any equipment or accessory is installed in a Great Lakes product the installation procedures recommendations and product warranty requirements of the equipment manufacturer must be followed Great Lakes will not be responsible for any losses or claims arising from a customer s installation of electrical electronic or other third party products in any Great Lakes enclosure unless caused solely by a written configuration prepared by Great Lakes for that customer or by a configuration provided by Great Lakes website any configuration relies on complete and accurate information from the customer Physical Equipment CISCO Recommended Dimensions Clearances Equipment Equipment to to Wall Equipment 25 RMU 43 75 32 00 11 00 22 00 14 RMU 24 50 24 00 11 00 22 00 armu 60v 1200 armu 2450 1840 25 6 _ ormu 333v 1810 i200 armu 2520 1810 600 1200 Parry 010 181
22. e manufacturer Removing the top panel can be done by removing the four 10 32 x 1 lg phillips pan head screws E Series or the four 10 32 x 1 2 lg screws ES Series Then simply lift the top panel out or off Top panels are available for 24 W TPE 24 and 29 W TPE 29 E Enclosures There are 5 options for E Enclosures indicates enclosure width in part number e AN TPE S TPE P TPE F 10 TPE 2F10 Solid Perforated Three 10 550 Two 10 550 75 CFM Fans CFM Fan CFM Fans There are 6 top panel options for ES Enclosures TPES S TPES P TPES F TPES F10 TPES 2F10 TPES B Solid Perforated Three 10 550 Two 10 550 Brush 75 CFM Fans CFM Fan CFM Fans Grommet BOTTOM PANELS E SERIES There are several styles of panels available for the bottom of your E Series enclosure Optional panels are solid filtered or brush grommet These panels have foam gasketing for a positive seal K and mount to four internally threaded studs using 10 32 x 1 2 lg phillips pan head screws The back opening can be covered with a solid metal cover These covers are specific to the width of the enclosure BOTTOM PANEL ES SERIES Bottom Panels brush grommet and solid for the ES series comes in two sections One for the middle opening and one for the rear Once you have unpacked the large flat rectangular middle section place it in the bottom of the enclosure with the
23. iddle rear Place the fan tray on the 10 32 screws Plug in the power cord and ensure that it goes through the small notch of the Air Manager see detail D INSTALLATION OF AIR MANAGER Place the Air Manager in the bottom of your ES enclosure attach using two cage nuts per side Use the wing nuts to secure the vertical air deflector After you have installed the Air Manager you can change the amount of airflow by sliding the adjustable panel Available Air Manager and Fan Trays include AM HFES High Flow Air Manager Assembly for ES Enclosures AM HFFTES24 High Flow Air Manager Fan Tray for 24 W Enclosures 940 CFM AM HFFTES30 High Flow Air Manager Fan Tray for 30 W Enclosures 940 CFM AM ES Air Manager Assembly for ES Enclosures AM FTES24 Air Manager Fan Tray for 24 W Enclosures 600 CFM AM FTES30 Air Manager Fan Tray for 30 W Enclosures 600 CFM Vertical Air Deflector Panel an RUN Notch in Rear of Air DETAIL D b Manager For Cord d DETAIL C A I Main Body Flange and Front 2 Diverter Mounted to Bottom Bil gt b 10 32 Wing Nuts for Vertical Deflector Mounting Notches AB E SA m RMU Rail Main Body Flange and Front Diverter Mounted to a uU 10 32 x 1 2 L Self Tapping Adjustable Screws Installed with 1 4 r Airflow Gap for Fan Tray Notches to Rest Qty 4 19 EXHAUST CHIMNEY amp FAN TRAY ES SERIES INST
24. ift straight up FIELD REVERSIBLE FRONT amp REAR DOORS The front and rear doors are installed right hand hinge as standard from the manufacturer Removing the hinges allows you to reverse the door by flipping them over and reinstalling the hinges using the universal mounting holes Begin both screws then tighten while maintaining perfect vertical alignment See detail below All enclosure frames and doors have provisions to be hinged right or left hand If the door is reversed the handle must be taken out rotated 180 and installed in the door again See Operating Handle on page 5 HINGE MOUNTING Pivot Washer Reversible Hinge Female Reversible _ Hinge Female im _ y Mi B Flat Head 4 7 Phillips Screw Flat Head 10 32 1 2 Phillips Screw b 10 32 x 1 2 amp DOOR DETAIL E 1 FRAME DETAIL SIDE PANEL REMOVAL The side panels are secured to the enclosure frame with two quick release latches and a keyed lock Be sure to unlock the side panel To remove the side panel squeeze the quick release latches towards each other Then tilt the top of the side panel out slightly and lift the side panel up a couple of inches until it is free To install the side panel reverse the process Make sure the slots on the side panel engage with the two tabs at the bottom of the frame W N N x 24
25. l load in the E and ES Enclosure load the heaviest equipment first at the bottom of the E and ES Enclosure and load the lighter units at the top OPERATING DOOR HANDLE The door swing handles E and ES Enclosures have been installed at the manufacturer No additional assembly is required To operate the swing handle lift up at the bottom of the handle then swing the handle to the right to open The handle must be kept in this position to close the door Return the handle to the initial position and use the key Lift Up Handle for provided to lock the handle The lock 30 W Mesh on the side panels will accept the Contour Doors same key The swing handles and doors are reversible Swing Handle All doors use swing handles except mesh contour doors 30 W ES cabinets use lift up locking handles Simply lift up to release If you are reversing the doors make sure to switch the latch bracket to the other side DOOR REMOVAL AND ATTACHMENT Open the door beyond 90 degrees grasp the door with both hands and carefully lift upward When the door is free of all three hinge pins pull the door away from the enclosure To attach the door align all three hinges of the door to their respective hinge pins on the enclosure and slowly slide the door down until seated E Hinge Pin Hinge Door eee E EA A N N Align all Open bis three id door MI beyond 90 l
26. ls Install the bracket onto the rail or post toward the side panel It is important to ensure you have 18 31 between the inner holes for 19 mounting PDU1 MOUNTING E and ES SERIES The 30 W ES and 29 W E allows for 0 RMU mounting of 19 rack mount power strip units or other 1 RMU equipment such as patch panels You can mount up to twelve 12 1 RMU pieces of equipment this way Install the bracket into the side panel flange Make sure you have 18 31 between the inner holes See detail B P EZ ol E P T Py d 18 31 Mounting 9 Holes 18 dj lt 9 9 e 10 32 Holes 18 AIR MANAGER amp FAN TRAY ES SERIES IMPORTANT If you are installing the optional fan tray please install before the air manager The Standard Air Manager will take up the first RMU in the bottom of your enclosure and the High Flow Air Manager will take up the first two RMU INSTALLATION OF FAN TRAY Install four 4 10 32 x 1 2 screws in the middle center of the ES enclosure Make sure to remove the cinch straps from the m
27. magnetic strip down To install the rear bottom panel first remove the cinch straps from the enclosure Find the push in fasteners 2 in the hardware bag line up the holes in the bracket with the rear opening of the enclosures and attach DETAIL 2 REVERSE SIDE Panel Slides Into Bottom Rear of Enclosure Between Rear Stiffener and Rear Door Jamb 38 Use Push Clips to Secure in Place 2 Align 0 25 Holes and Flush with Stiffener 2 places Magnetic Strip Hold Bottom of Panel to Enclosure MOUNTING RAILS The vertical mounting rails each enclosure has two pairs 12 ga steel powder coated rails come installed with all standard frames at 19 EIA 310 E The 29 W REA E Series enclosure and the 30 W ES enclosure can configured to 23 EIA mounting with an optional replacement bracket set Universal cage nut rails M6 are standard Tapped 10 32 rails are available Must be specified at time of order Rack Mount Units RMU are marked on rails for easy equipment mounting Flexible Mounting Profile FMP round cable pass through holes and vertical and FMP horizontal cable tie down slots can be found on side of rails 10 RAIL USTMENT E amp ES Series Rails are attached using a sliding nut plate and a 1 4 20 hex head bolt By loosening the top and bottom bolts using a 3 8 drive socket the rails can be adjusted infinitely front and back P e STANDARD POWER STRIP MOU
28. r for 84 H enclosures It can be mounted between two enclosures or mounted on a single enclosure The side car has two vertical troughs fingers and attachment points for cable ties and cinch straps For complete side car installation instructions visit werackyourworld com drawings Available side cars include 5668442 External Cable Manager 84 6 W 42 for use with 84 H x 42 D ES Enclosures SC68448 External Cable Manager 84 H x 6 W x 48 D for use with 84 H x 48 D ES Enclosures SC128442 External Cable Manager 84 H x 12 W x 42 D for use with 84 H x 42 D ES Enclosures SC128448 External Cable Manager 84 H x 12 W x 48 D for use with 84 H x 48 D ES Enclosures SCP8442 End Panel for External Cable Manager for use as an end of row cover panel A EX oy Oey etn Ung Oley A Ron SU BU su iC SAN SW esas EE Severe agsys aagseyse 17 ZERO RMU MOUNTING ZR1 amp ZR2 E and ES SERIES Both ZR bracket kits fit on the 30 W ES and 29 W E enclosures These allow for 0 RMU mounting of 19 rack mount power strip units or other 1 or 2 RMU equipment such as patch pane