Home

Diagnostic Imaging Product Catalog

image

Contents

1. Dimensions inches Model Model with FAS Shipping Viewing area Wall cutout option wot Ib Length Height 1 panel 14 in x 17 in 14x 17 14 75 21 75 71 201VR 77 201VR FAS 24 2 panel side by side 28 x 17 28 75 21 75 77 202VR 771 202VR FAS 48 3 panel side by side 42x17 42 15 21 75 77 203VR 771 203VR FAS 72 4 panel side by side 56 x 17 56 75 21 75 77 204VR 771 204VR FAS 96 5 panel side by side 70 x 17 70 75 21 75 77 205VR 771 205VR FAS 120 6 panel side by side 84x 17 84 75 21 75 77 206VR 77 206VR FAS 144 1 over 1 14 in x 17 in 2x 14x17 14 75 42 15 77 211VR 77 211VR FAS 48 2 over 2 2xX28x 17 28 75 42 15 77 222VR 71 222VR FAS 96 3 over 3 2x42x 17 42 15 42 15 77 233VR 71 233VR FAS 144 4 over 4 2x56 x 17 56 75 42 15 77 244VR 71 244VR FAS 192 5 over 5 2x70x 17 70 75 42 15 77 255VR 71 255VR FAS 320 crated 6 over 6 2x 84x17 84 75 42 15 77 266VR 771 266VR FAS 368 crated Viewing height is actually 16 5 inches in order that extraneous light is eliminated when standard 14 in x 17 in film is inserted Overall recessed fixture dimensions including recessed trim length and height are each three inches greater than surface mounted dimensions Film Activated Switches FAS options Replacement parts Optional accessories 71 MS REPL On Off Master Switch 71 CS Cluster Switching 771 CS REPL Cluster Switching 11 MS On Off Master Switch 72 EEE REPL Ballast 71 HGP Ho
2. Model Filter Weight Length Width Filter holder Application Configuration required 57 429 Chest 16 oz 5 125 in 5 125in No PA View 72 in FFD 57 432 2 inch Wedge 3 4 oz 6 5 in 2in Yes All lateral decubitus position Lateral Decubitus see 57 426 views I at 40 in FFD e Angiography of neck and head use 2 filters 57 433 3 inch Wedge 5 50z 6 5in 3in Yes Suggested for children Lateral Decubitus see 57 426 at 40 in FFD 57 426 Filter Holder 24 oz 6 5 in 6 5 in Has two steel rails WxD 1 in x 5 5 in for Required for set of mounting positioning filters and shields Only one O 57 432 57 plates included F Iter Holder is needed per x ray machine 433 57 441 Comes with a Plexiglas cutter 57 440 Foot and Ankle Filter 3 9 oz 6 5 in 2in No AP foot 1 e Podiatric equipment 57 441 2in Wedge AP Foot 2 oz 6 5 in 2in Yes Lateral and oblique E at 40 in FFD see 57 426 Axial view of calcaneus 57 414 Wall Rack 8 oz 12 in lin Can hold a complete filter set plus 3 to 5 extra filters Two sided foam tape holds the rack to the wall 57 411 Replacement 6 50z 9in Qin Attaches to filter holder with screws Easily cut 77 Mounting Plate to fit collimator assembly Set of two 57 405 AP PA 72 in FFD 5 oz 6 5 in 2 5 in Yes Lateral chest see 57 426 i 57 415 AP PA 40 in FFD 9 oz 6 5 in 4 125 in Yes Sectional AP cervical thoracic j see 57 426 57 406 Lateral Cervical 3 2 oz 6 5 in 1 25in
3. Material Gold nickel construction equivalent to 25 microns of lead or 2 6 mm of aluminum Dimensions LxW 25mm x 12 5 mm Thickness 0 0175 mm 0 0152 mm gold 0 0025 mm nickel Designed by Carol Mount R T R M and Joel E Gray Ph D Department of Diagnostic Radiology Mayo Clinice Rochester MN 55905 Manufactured under licensing agreement with Mayo Foundation for Medical Education and Research Mammography Quality Assurance Biomedical Key features With a single exposure you can e Measure the contrast and dynamic range of the imaging system e Easily measure the system resolution of the focal spot length and width on mammography units with optional Resolution Test Pattern 07 555 Phantom with two 5 20 LP mm test patterns optional in parallel and perpendicular orientation Also includes an air step wedge with aluminum attenuator Optional accessories 07 555 Resolution Test Pattern The 18 252 Contrast Detail s Phantom for Mammography is designed to provide a means of quantitatively testing and mon itoring the total performance of an entire mammographic imaging chain Its small size as well as the number and distribution of holes simulating embedded objects make this phantom particularly useful in evaluating digital spot mam mography systems With 49 holes generating subtle con trast variations the phantom makes it possible to dete
4. Minimum CRLU rate 1 5 sec approx 0 15 mR sec entrance exposure rate 7 sec approx 0 7 mR sec entrance exposure rate 07 QRX Maximum CRLU rate 2500 sec approx 250 mR sec entrance exposure rate 25000 sec approx 2500 mR sec entrance exposure rate 07 QRX Power on off Manual switch Controls Wireless communications with computer software Bluetooth wireless communications 07 CRX only Functions Measures CRLU AEC converts CRLU to CR manufacturers specific CR plate reader light exposure index value EI user selectable calculates cassette input exposure values for various x ray beam conditions exposure in mR plus backscatter Power requirements Built in NiMH rechargeable battery pack 9 6 V Typical battery life 5 hours 20 hours 07 QRX between charging X ray beam filter 1 5 mm copper B152 110 6 in x 6 in complete with velcro straps to attach to x ray tube collimator housing Environmental Operating temperature 15 C to 35 C 59 F to 95 F requirements General information Electronic cassette 30cm x 24cm x 1 3 cm 12 in x 10 in x 0 5 in dimensions WxDxH Weight 1 8 kg 3 9 Ib Computer software CD ROM containing Microsoft Excel program Computer requirements Computer capable of running Windows 98 or higher with Microsoft Excel Computer not required to operate 07 QRX Software is provided with 07 QRX to manually enter values if desired Optio
5. Radiography Fluoroscopy Phantoms and Accessories Key features e Quick and easily optimize images from your CR DR system e Effectively reduces equipment downtime e Incorporates the DIN standard test pattern DIN 6868 58 e Dramatically reduces repeat patient exams thus prevent ing unnecessary patient exposure due to problems related to the image acquisi tion chain and poor image quality e Lightweight durable e Easy to use no moving parts e Cost effective e Quickly verifies impor tant parameters including dynamic range contrast resolution homogeneity and resolution 68 The 07 647 R F QC Phantom is designed to provide the diagnostic radiologic tech nologist with an accurate easy to use tool for evaluating the image quality and perfor mance of standard diagnostic radiographic and fluoroscopic imaging systems For fine tuning of radio graphic and fluoroscopic imaging systems it is recom mended that the phantom be imaged at least monthly on all radiographic and fluoroscopic equipment To attain the most accurate up to date quality control information a daily or weekly frequency is preferable When used daily the R F QC Phantom will allow the technologist to quickly determine whether the equipment is functioning cor rectly This easy to use phantom allows the user to complete the suggested protocol in approximately five minutes or less when used on a standard R F s
6. 80 kV to 160 kV 22 kV to 35 kV 1 2 mm of Al 30 p of Mo Mo Mo Mo Rh 22 kV to 40 kV 25 p of Rh Mo Al 22 kV to 49 kV 1 mm of Al Rh Rh 25 kV to 49 kV 25 u of Rh Rh Al 25 kV to 49 kV 1 mm of Al Radio and mammo All calibrations performed with NIST traceable calibration beam Analyze display cycle time Three seconds for 0 1 second exposure ine second for each 32 ms of exposure time Fluoro and AMSE Time Radio mode 15 seconds for all exposures Measured during entire exposure at 90 80 75 rise fall of waveform zero crossing or pulse count Mammo mode Measured during entire exposure at 90 rise fall of waveform pressure correction Measured quantity Accuracy 1 ms Resolution 0 1 ms Range All diagnostic exposures from 1 ms to 60 seconds Exposure and rate Measured during entire exposure with automatic energy temperature and Roentgens or grays Accuracy 5 Reproducibility Radio and mammo modes 2 or 2 mR Resolution 0 1 mR Range All diagnostic exposure and rate measurements from 1 mR to 9999 R Fluoro rate 0 1 R min to 999 R min mAs and mA Measured invasively during entire exposure Accuracy 2 Reproducibility 1 or 0 2 mAs Range 0 1 mAs to 9999 mAs 0 to 1000 mA HVL Accuracy 5 Range 0 1 to 99 9 mmAl Physical Display Super bright 240 x 60 pixel super twist LCD with cold cathode fluoresc
7. Biomedical Biomedical Key features e Optimized for evaluation of digital systems e Improves diagnostic accuracy oes Most definitions of image e Can also be used for conven quality in radiology are based tional radiography systems on characterizing the physical properties of the image chain HEED However medical diagnosis is not made by the image alone observer perception greatly Used to evaluate loss of detail in e Film digitizers e Computed Radiography CR systems affects the result Display monitors Digital radiography e Laser printers The 07 652 CDRAD Phantom is an excellent tool for evaluating the imaging characteristics of digital radiographic systems including stimulable phosphor computed radiography systems and teleradiography systems One of the principle concerns with the use of digital radiog raphy is the potential reduction in the visibility of detail due to the blurring introduced at various places within the system such as the film digitizers display monitors and the sampling of the image into discrete pixels Loss of detail is the image character istic which can have an adverse affect on diagnosis Resolution bar phantom test objects which are used to evaluate conven tional x ray imaging systems are generally not appropriate for evaluating digital systems The 07 652 CDRAD Phantom provides a reliable and objective evaluation of the loss of detail from blur ring a
8. Figure 2 Spatial Resolution the 1 4 and 1 6 line pair mm targets are resolved The 1 8 and 2 targets are not resolved Radiography Fluoroscopy Phantoms and Accessories Biomedical Key features e Independent confirmation Reassurance of an optimally working system Quick evaluation The machine is tested in its clinical configuration Verification That the system actually needs to be serviced allowing you to save time money and avoid more serious problems later on e Ease of use Anyone with technical knowledge can do the tests to determine if corrective action is necessary e Peace of mind To make sure that you are getting just what you paid for iy y Air cylinder MH a ea aa Air test pin er ea a a at Lead test pin E A me Sot i mas y Aluminum cylinder J ie rt m Figure 3 Photograph and diagram of the central test plate Note the resolution test plate iodine contrast detail targets and working thickness range targets e Low contrast detectability Four sets of holes with diameters of 4 mm 3 mm 2 mm and 1 mm are filled with elemental iodine dispersed in epoxy The relative areal concentration of iodine in the four patterns is 20 10 5 2 5 mg cm The test operator is required to identify the smallest visible pair of targets in each pattern See Figure 4 Visibility of moving structures A rotating spoke target allows visual evaluation of motion unsharpness and t
9. 199XRAY Medical Scopemeter The 199XRAY Medical ScopeMeter has all the normal oscilloscope functions as well as the speed performance and analysis power for more demanding applications This high performance oscillo scope offers the functionality of top end bench instruments With up to 200 MHz bandwidth 2 5 GS s real time sampling and a deep memory of 27 500 points per input the 199XRAY is ideal for engineers who need the full capabilities of a high performance oscilloscope in a handheld battery powered instrument In addition the 199XRAY is specially designed for use with x ray systems This ScopeMeter displays kVp waveforms and direct kVp values simultaneously on an easy to read screen eliminating time wasting calculations of scope traces to derive kVp values Diagnostic X Ray Quality Assurance Instruments Biomedical Key features 35080M e New miniaturized configura tion for convenient transport to the job site e Fast easy non invasive kVp values for calibration QA e Non invasive technology eliminates the hazards of high voltage cables and the need for bulky divider tanks e Auto ON OFF when connected disconnected e Optional filter packs enable testing in all modalities e Rh Rh measurement capability when 35080M is used with Cadmium K Edge and Linear Mammo Filter Pack Pair e Convenient storage carrying case 199XRAY e ScopeMeter displays kVp wave forms and direct kVp values simultaneously on an ea
10. The accurate indexing capa bility and exceptional image quality of the computed tomog raphy CT scanners not only guarantee the object s loca tion and its size and shape but also improve the diagnosis accuracy The index and per formance parameters of the CT scanners cannot be confirmed without objects of known specifications The 76 432 CT Spiral Phantom provides specific details necessary to confirm the integrity of both conventional and spiral scan ning What makes the phantom unique is that it allows the user to visually evaluate all test results in their image displays The 76 432 consists of five Lucite plates of different sizes all affixed to a flat rectangular base Specific hole patterns are drilled on each side of these plates When imaging the holes within the x ray field will appear in the phantom images By the hole appearance both index and performance parameters can be confirmed qualitatively and quantitatively Parameters that can be confirmed by the phantom based on the hole appearance in the phantom images include Index parameters e Light localizer orientation e Light localizer and image slice congruence e Slice thickness accuracy e Gantry inclination e Couch index accuracy e Ruler angle and distance accuracy Performance parameters e Slice geometric uniformity e Image geometric distortion e Image slice overlap e Slice thickness change by pitch factor and image interpolation e
11. Beam Alignment Test Tool In radiographic quality control it is essential to verify proper alignment of the collimator light field with the x ray field The O7 661 7662 readily indicates a 1 or 2 misalignment at a 40 in focal film distance FFD but it may be used at any FFD It consists of a flat 8 in x 10 in plate with a 14 cm x 18 cm pattern etched on its surface It can also be used to check fluoroscopy alignment and collimation Improper central ray align ment will distort a radiographic image The O07 661 7662 provides a simple means of determining if the x ray beam is perpendicular to the image receptor and centered with respect to the light field A steel ball is mounted in the center of a disc at each end of the 15 cm high clear plastic cylinder When the balls are positioned over one another and at a right angle to the film their images will appear as one if the central ray is truly perpendicular to the film The approximate degree of improper angulation can also be determined 027 661 7662 Dimensions beam alignment 15 cm h x 006 3 OD cm 5 9 in x 2 5 in Weight beam alignment 0 24 kg 0 54 1b Weight collimator 0 19 kg 0 41 Ib 07 644 Lead plates Three plastic covered 0 062 inch thick lead plates 1 9 125 in x 3 625 in test plate 2 3 56 in x 2 375 in blocker plates Test plate 5 0 375 inch test holes and 5 0 062 in orientation holes Weight 0 68 kg 01 5 1b Diagn
12. Dimensions nominal LxWxH 84 555B Material Saran based 15 cm x 15 cm x 14 7 cm 5 9 in x 5 9 in x 5 79 in Zerdine solid elastic water based polymer Freezing point O C 32 F Melting point above 100 C 212 F Attenuation coefficient 0 5 dB cm MHz 0 05 dB cm MHz Speed of sound 540 m s 6 m s Targets See pattern Scanning membrane Saran based Dimensions nominal LxWxH 10cm x 15 cm x 18 5 cm 4in x 5 9 in x 7 3 in Scanning membrane Saran based GROUP 1 GROUP 2 laroup s GROUP 6 Figure 1 A Figure 1 B 1 t Figure 2 B Ultrasound Quality Assurance Biomedical FLUKE o Biomedical Gray Scale Key features Ultrasound Phantom e 21 testing objects Diameters 2 4 mm 4 mm and 6 4 mm Contrast anechoic 9 6 3 The newly designed 84 347 3 6 and 9 dB Gray Scale Ultrasound Phantom Depth of test object varies uses proven patented materials continuously as phantom is scanned laterally e Scatter controlled indepen dently from attenuation e For evaluating resolving to permit rapid visualization of gray scale resolution power at continuous depths from 1 cm to 12 cm i i power as a function of depth 84 347 is a single simple size and contrast tool used to assess resolution of e Complies with ACR masses
13. Included accessories 8000 100 5 Control Console 8000 101 5 Detector 105 252 Detector Cable 105 253 and 105 254 mAs Leads 8000MAX Excel Add in 38667 HVL Plates 8000 200 1 Instruction Manual 8000 70 Carrying Case Ordering information 8000 NERO mAx X Ray Test Device E E Da item pee pee Dee ete ries Ae mie ee Oe eet RS ko eih bein Oe aal a9 si m Fb ee es ee ae Neier Core Par 4 Chew uta I J E Tan cheered ng ris E z Equipment Teire Dwn A Aun D Tae Sfp weet Aneel Kecel WO P magii Biram LEI Bip masgh te i od irs Eton spew ore Tree H iM aphy Phototimer Technby i i Pay Shet S f aty SA Dirai Depis EE eS es ee E Pe eee B i erm Ey pe 1 Mammagpraphie Unit Assembbhy Evaluniiorn efi eian Gi i ain AE T a J Baa Fie Gig y i d Sime fe l ija fa 5 Baay a Pea tees The NERO mAx Toolkit for Excel is a complete software package for the NERO mAx that includes an Excel Add In called NERO mAx Add In and Excel templates that may be used to evaluate the performance of radiographic mammographic and fluoroscopic x ray machines The NERO mAx Add In collects measured results from the NERO mAx and places the data in the cells of the active Excel worksheet starting at the active worksheet cell The NERO mAx Add In also may be used to acquire and graph radiation and kV waveforms from the NERO mAx as well as remotely control the NERO mAx pee mem en Drim b AOH bid EA
14. Mediolateral ML Localize define Lateromedial LM Localize define Spot compression SPOT Define Magnification M Define Exaggerated craniocaudal XCCL Localize Cleavage CV Localize Axillary tail AT Localize define Tangential TAN Localize define Rolled lateral RL rolled lateral t Localize define Rolled medial RM rolled medial t Localize define Caudocranial FB from below Define Lateromedial oblique LMO Define Superolateral to infermedial SIO Define oblique Implant displaced ID Augmented breast Used as a suffix after the projection For example LCCRL equals Left Craniocaudal Upper Breast Tissue Rolled Laterally Taken from ACR Mammography Quality Control Radiologic Technologist Manual Used as a prefix before the projection For example RMMLO equals Right Magnification Mediolateral Oblique Mammography Quality Assurance FLUKE o Biomedical Key features e Meets all requirements for standardized terminology set forth by the MQSA and Ameri can College of Radiology e Standardized labeling of mammography films is essen tial to ensure that films are not misinterpreted Choose from the following kits e Standard Kit normal requirement Consists of eight markers for the most frequently used positions Weight is 0 24 kg 0 5 1b e Specialty Kit Consists of 14 specialty markers Weight is 0 5 kg 1 1b e Full Service Kit Consists of 22 markers Standard Kit plus 14 specialty markers fo
15. Slice thickness 1 mm or 2 mm gap Slice position separation Gradient strength Slice thickness ramp section Four sections 2 with 1 mm gap 2 with 2 mm gap MRI Quality Assurance Key features 76 907 Accurately evaluates e Spatial linearity e Image artifact e Signal to noise e Resonance frequency e Quadrature error 76 908 Accurately evaluates e High contrast resolution e Slice thickness e Gradient strength e Slice position separation e Resonance frequency e Designed to conform to AAPM MRI specifications These phantoms conform to the AAPM Specifications contained in the report Quality Assurance Methods and Phantoms for Magnetic Resonance Im aging issued by the AAPM NMR Task Group No 1 article appeared in Medi cal Physics 17 2 Mar Apr 1990 This report has also been co sponsored by the American College of Radiology MR Committee on Imaging Technology and Equipment Optional accessories 716 903 7000 Copper Sulfate 1 gm l f Da aa B e TF hA af p w i 3 c r _ P E am Five section insert The use of surface coils in Magnetic Resonance Imaging MRI has become an important part of the clinical operations in most MR facilities Surface coils are preferred in some MR studies in part because their use can minimize motion artifacts obtain high signal to noise ratio in the areas closer to the surface and obtain hig
16. tioned on the bucky with the smallest disc diameters at the thorax side in combination with one or more Plexiglas plates The markings on the Plexiglas plates should be aligned at the thorax side of the bucky On digital stereotactic systems with smaller fields of view specific portions of the phantom can easily be imaged as well The density of the image has to be checked after the film has been processed In a series of CD images all images should approximately have the same densities in a reference position on the film Dimensions WxDxT Plexiglas plates 162 5 mm x 240 mm x 10 mm 6 38 in x 9 45 in x 0 4 in Aluminum base 162 5 mm x 240 mm x 0 5 mm Weight 2 06 kg 4 54 Ib Mammography Quality Assurance Proven simulation technology enables the use of tissue equivalent realistically shaped phantoms for mammographic quality control The 18 222 Tissue Equivalent Mammography Phantom contains targets that are engineered to test the threshold of the new generation of mammography machines The phantom is 4 5 cm thick simulates a 50 glandular tissue composition and is designed to test the performance of a mam mographic system by a quantitative evaluation of the system s ability to image small structures similar to those found clinically The phantom is designed to determine if your system can detect small structures that are important in early detection of breast cancer Test objects within the
17. 3335795 TNT 12000D Wireless Display Included accessories 1330005000 TNT 12000D Wireless Display 14 445 1 AC Adapter Charger 50 197 Cable Type A to Mini B USB 50 198 Cable Mini A to Mini B USB 1320003000 Excel Software User Manual on CD TNT12QRG Quick Start Reference Guide CE 35080M 199XRAY The winning combination The 35080M and 199XRAY are commonly used x ray tools unmatched by traditional meters This winning com bination allows busy service engineers and biomedical per sonnel the ability to perform fast and accurate verification of kVp values for calibration or QA assessment Fluke Biomedical offers this combination in a convenient kit with all the accessories you need to get started 35080M Non Invasive kVp Divider The 35080M Non Invasive kVp Divider quickly and accurately measures kVp for all modali ties The unit checks both above and below table tubes and displays the direct kVp values on either the 35050AT Dosimeter the 199XRAY Medical ScopeMeter or optional Excel Add in software The 35080M is highly portable and eliminates the need for bulky and heavy high voltage divider tanks In fact it s so compact in size that it fits into a shirt pocket A patented wide range filter pack is included with the 35080M and provides accurate readings for the range of 50 kVp to 150 kVp Four optional filter packs are available for use with the 35080M for CT mammographic and mobile applications
18. 800 850 4608 or Fax 440 349 2307 In Europe M East Africa 31 40 267 5435 or Fax 31 40 267 5436 From other countries 1 440 248 9300 or Fax 1 440 349 2307 Email sales flukebiomedical com Web access www flukebiomedical com Service Center Repair Calibration US Fluke Biomedical 6045 Cochran Road Cleveland OH 44139 3303 Tel 440 498 2560 Toll free 800 850 4608 ext 2564 Email globalcal flukebiomedical com Service Center Repair Calibration Europe Fluke Biomedical Europe Science Park Eindhoven 5110 5692EC Son The Netherlands Tel 31 40 267 5435 Fax 31 40 267 5436 Email servicedesk fluke nl Biomedical Diagnostic Imaging Product Catalog Film Processor Quality Assurance 07 444 The Little Genius Scanning Densitometer se sesesesiersserierrierrssrreerisrrrsrrrernssriennrerrnsnrennne 80 07 443 Handheld Deluxe Digital Clamshell Densitometel eeececsceseseteeeeeeteeeeeeeeeeeeeteeeeeeeeeeeeees 81 07 417 Handheld Dual Color Sensitometer 0 ceeeeseeeeneseeeeeseeeesseeneeasaeeesceaeaseeenseneasenenaes 82 07 402 Portable Digital Thermometer 07 424 Digital Densitometer sccccsccscsscssvissovisvssvusvusesvisssssusvsvisiususussnusrissusisnusvuse Film Handling and Storage 77 201TR TS MAXANT TECHLINE Illuminators 77 101HL MAXANT High Intenstiy Hot Lamp 77 201VR VS MAXANT MVP Illuminator eeseeeecseeeeeeeeeeeeees 18 231 2350 Fixer Retention QC Test
19. Dimensions WxDxH 13 34 cm x 19 37 cm x 9 21 cm 5 25 in x 7 625 in x 3 625 in Weight 1 14 kg 2 5 1b Film Processor Quality Assurance FLUKE o Biomedical Key features e Helps maintain optimum film processing conditions e Easy selection of blue or green light emission e Lightweight portable battery operated e Repeatability 0 04 OD log exposure from unit to unit e Stability 0 02 OD log expo sure per year at 10 C to 45 C e Numbered 21 step density wedge Optional accessories 89 417 Carrying Case Available ac adapters for specify with order 14 301 110 V ac 9 V de 500 mA USA and Japan 14 399 230 V ac 9 V dc 500 mA Europe 14 415 230 V ac 9 V dc 500 mA UK 14 415 and 14 416 Adapter 230 V ac 9 V dc 500 mA Australia Ordering information 07 417 Handheld Dual Color Sensitometer Portable Digital Thermometer This 07 402 Portable Digital Thermometer is a battery powered unit with a detach able immersion probe Temperature readings appear in Centigrade or Fahrenheit with 0 5 accuracy The LED display eliminates prob lems that can result from the misreading of stem type thermometers Detachable immersion probes are time savers for x ray departments that have several film processors The use of mul tiple probes each remaining in a specific tank also eliminates the possible cross contamina tion of chemicals C The 07 402 includes many con
20. FDA QSR as applicable and NRC Part 50 Appendix B Part 21 and adheres to ISO 17025 2005 ANSI Z540 Mammography MQSA and CNSC Many of the Fluke Biomedical products are CE marked and CSA certified In addi tion the Global Calibration Laboratory holds its NVLAP Lab Code 200566 0 certification and is traceable to both the NIST amp PTB Legacy You may be familiar with some of our legacy brand names includ ing e Victoreen e Nuclear Associates e DNI Nevada e Keithley e Bio Tek Instruments Fluke Biomedical has taken the best elements and products of these former brands and have incorporated them into the Fluke Biomedical culture and product line available today Metron Our newest catalog Thank you for requesting our Radiation Oncology catalog Within these pages you will find solutions to manage your quality assur ance and maintain a safe regulatory compliant facility in the radiation oncology physics field If you are interested in receiving catalogs or information about any of Fluke Biomedical s other product lines please visit www flukebiomedical com catalog Catalogs are available for the following product lines e Biomedical Test e Radiation Safety e Diagnostic Imaging QA e Service About Fluke Biomedical Fluke Biomedical leads the world in the manu facture of biomedical test and simulation products including standalone electrical safety testers to fully integrated and automated performance testing
21. Minimum 90 collection efficiency at 20 R sec Automatic reset Resets display to zero can also be reset manually Operating temperature 10 C to 40 C Relative humidity O to 90 non condensing Display 3 5 in x 0 5 in LCD low battery indicator Controls Auto or manual reset selector Display zero reset button Dose or dose rate output selector Integral or remote ion chamber selector On off switch Power 9 V alkaline battery gt 100 hours operation 50 hours in manual reset mode Dimensions WxDxH 15 25 cm x 15 9 cm x 7 cm 6 in x 6 25 in x 2 75 in Weight 6000 528 0 51 kg 1 125 lb Optional external chamber accessories 30 cm Energy response within 7 from 30 kVp to 150 kVp 15 keV to 65 keV Cable 4 5 m 15 ft Chamber dimensions 10 2 cm x 10 2 cm x 1 4 cm 4 in x 4 in x 0 54 in thick 6000 529 3 3 cm Energy response within 5 from 0 2 mm to 5 0mm Al HVL 16 kVp to 90 kVp Cable 4 5 m 15 ft Chamber dimensions 4 cm x 1 5 cm thick This chamber meets the needs of the MQSA for an external transparent chamber 6000 530B 150 cm Energy response 10 from 1 8 mm to 10 mm Al HVL Cable 3 m 10 ft Chamber dimensions 15 9 cm x 20 6 cm x 1 6 cm 6 26 in x 8 in x 0 63 in 6000 100 3 2 cm Energy response 5 from 1 mm to 10 mm Al HVL Cable 0 9 m 3 ft Sensitive length 10 cm 4 in Chamber inside 6 4 mm 0 25
22. Select exposure only for external ion chamber Mo Mo or W AI Select anode filter of x ray tube Connectors Power 9 V dc 500 mA Scope BNC for oscilloscope connection RS 232 DB 9 connector configured as DCE BNC and banana plug for external Ion chamber Power requirements 9 V dc 500 mA external supply Rechargeable internal Ni Cd batteries supply more than six hours of continuous service with overnight charge Dimensions WxDxH 21 5 cm x 23 cm x 7 6 cm 8 5 in x 9 in x 3 in Weight Approximately 1 59 kg 3 5 1b HVL set Aluminum filters 2 3 mm 1 0mm and 0 3 mm Optional external chamber accessories 6000 528 30 cm Energy response within 7 from 30 kVp to 150 kVp 15 keV to 65 keV Cable 4 5 m 15 ft Chamber dimensions HxWxT 10 2 cm x 10 2 cm x 1 4 cm 4 in x 4in x 0 54 in 6000 529 3 3 cm Energy response within 5 from 0 2 mm to 5 0 mm Al HVL 16 kVp to 90 kVp Cable 4 5 m 15 ft Chamber dimensions 4 cm x 1 5 cm thick This chamber meets the needs of the MQSA for an external transparent chamber 6000 530B 150 cm Energy response 10 from 1 8 mm to 10 mm Al HVL Cable 3 m 10 ft Chamber dimensions HxWxT 15 9 cm x 20 6 cm x 1 6 cm 6 26 in x 8 x 0 63 in 6000 532B 400 cm Energy response 5 from 32 keV to 662 keV Cable 3 m 10 ft Chamber dimensions HxWxT 15 9 cm x 20 6 cm x 1 6 cm 6 26 in x 8 in x 0 63 in 6
23. The Radiation Oncology QA catalog provides a full range of QA solutions for the Radiation Oncology Physicist Therapist and Dosimetrist The catalog contains information about the linear accelerator QA instruments radiation oncology chambers phantoms and accessories needed to manage radiation oncology QA and maintain a safe regulatory compliant facility For more information contact sales flukebiomedical com Fluke Biomedical Radiation Safety The Radiation Safety catalog highlights devices used to measure radiation levels manage regulatory QA requirements and aide in radiation emergencies These devices are intended for Radiation Safety Officers RSOs Health Physicists Emergency Responders and other radiation minded professionals The catalog contains information about a variety of survey meters and probes area monitors and other radiation monitoring accessories For more information contact sales flukebiomedical com Fluke Biomedical Test The Biomedical Test catalog emphasizes the complete line of biomedical test and simulation products for Biomedical Clini cal Engineers and Technicians The catalog contains information about Fluke Biomedical s test and simulation products includ ing standalone electrical safety testers patient simulators and performance analyzers as well as fully integrated and automated performance testing and documentation systems For more information contact sales flukebiomedical com Fluke B
24. Vpwm Vpwm function for motor drive and frequency inverter applications mA mAs measurement calculates current over time Using the cursors you can now measure directly the amount of radiation produced by x ray systems or the total amount of charge applied to a system Smart averaging Smart averaging gives the averaged waveform over successive acquisitions reducing noise in the displayed waveform Thanks to smart averaging you can now also see an incidental curve of a different wave shape with no effect on the averaged curve This allows you to see the averaged curve of a sequence of video lines for example while still seeing the incidental flyback line flash by The oscilloscope gives an immediate response when the signal makes large changes Extended offset Vertical offset is now extended to a maximum of 16 divisions allowing vertical zoom in for study of small details of the signal Electrical safety 1000 V CAT II and 600 V CAT III safety certified Power requirements Rechargeable NiMH battery pack four hours operation Dimensions LxWxH 25 6 cm x 16 9 cm x 6 4 cm 10 1 in x 6 6 in x 2 5 in Weight 2 0 kg 4 4 Ib FlukeView for Windows Documenting Transfer waveforms screens and measurement data from the ScopeMeter to a PC Print or import the data into your report Enhancing Add user text to individual ScopeMeter settings providing guidance to the operator
25. accuracy and ease of use Each Service QC kit includes an easy to carry durable insulated carrying storage case to keep your equipment safe wherever you go e Optional mAs meter available Included accessories 89 426 Carrying Case 18 526 3000 06 526 5240 RAD CHECK MICRO R 07 494 Wide Range Digital kVp Meter 07 453 Digital X Ray Pulse Counter Timer 06 524 3000 Image Intensifier Ionization Chamber 100 cm 18 526 1000 06 526 RAD CHECK PLUS 07 492 Mammographic Digital kVp Meter 07 453 Digital X Ray Pulse Counter Timer 6000 529 Mammographic Ion Chamber 3 3 cm 18 526 2000 06 526 RAD CHECK PLUS 07 494 Wide Range Digital kVp Meter 07 453 Digital X Ray Pulse Counter Timer 6000 528 Radiographic Ion Chamber 30 cm 18 526 4000 06 526 RAD CHECK PLUS 07 479 Dental Digital kVp Meter 07 453 Digital X Ray Pulse Counter Timer 07 453 2000 Remote Sensor for use with 07 453 6000 528 Radiographic Ion Chamber 30 cm Ordering information 18 526 3000 Cardiac Cath Special Procedures QC Kit 18 526 1000 Mammography QC Kit 18 526 2000 Radiography Fluoroscopy QC Kit 18 526 4000 Dental QC Kit Digital X Ray Pulse Counter Timer Poor or inconsistent quality of X ray images is caused by an inaccurate generator timer This results in repeat examinations which cost time and money A poorly maintained system is also hazardous to the patient When a malfunction in the timer occurs the patient may receive unne
26. 100 mm x 125 mm x 20mm Weight 0 57 kg 1 3 lb Optional accessories 18 216 2555 Acrylic Wafer Test Pattern Mammography Quality Assurance FLUKE o Biomedical 18 228 and 18 229 1313 Key features 18 228 e Compressible With the increasing use of e Contains cysts dense masses stereotactic breast biopsy ciate CIEE ks procedures it is essential Fropnictaty gel sunulates that radiology healthcare pro Phys aucers Wenge attenuation of BR 12 viders maintain and increase Gel will not dry out after Stereotactic Biopsy Phantoms their needle biopsy skills initial needle punctures thus The 18 228 tissue equivalent extending storage life phantom is a MUST for every e Physical consistency similar mammography facility to human tissue combined The automated stereot with an elastic skin like 2 i membrane enables palpation 18 228 Stereotactic Needle Biopsy Tissue Equivalent actic breast biopsy procedure of embedded structures and Training Phantom depends on several variables accurately simulates needle for accurate needle placement resistance Thus for patient safety this system must be properly maintained e Anthropomorphic shape and evaluated allows for accurate simulation This versatile 18 228 was designed to assist in training tech of breast compression nologists and physicians in the use of a stereotactic system and 18 229 1313 for verifying the proper operation of mammographic stereotactic e The mo
27. 25 cm x 5 08 cm clear acrylic Weight 76 214 Dimensions WxDxH Weight 76 215 This kit contains all the components needed to make any one of the phantoms on this page 12 kg 26 5 lb 1 25 cm x 25 cm x 1 mm piece of high purity alloy aluminum sandwiched between 2 sheets of 25 cm x 25 cm x 2 54 cm clear acrylic 4 5 kg 10 lb Dimensions WxDxH 5 25 cm x 25 cm x 2 54 cm thick acrylic sheets 1 25 cm x 25 cm x 5 08 cm thick acrylic sheet 1 25 cm x 25 cm x 1 mm thick aluminum sheet 1 25 cm x 25 cm x 2 mm thick aluminum sheet 1 7 cm x 25 cm x 4 5 mm thick aluminum sheet Spacers for a 5 08 cm air gap Weight 15 3 kg 34 lb Radiography Fluoroscopy Phantoms and Accessories FLUKE o Biomedical Included accessories 76 211 Spacers to provide a 5 08 cm air gap 76 212 In order to provide additional attenuation in the spinal region a7cmx25cmx4 5 mm thick piece of high purity alloy aluminum is included Ordering information 76 211 Chest X Ray Phantom 76 212 Abdomen Lumbar Spine Phantom 76 213 Skull X Ray Phantom 76 214 Extremity X Ray Phantom 76 215 Make Your Own Phantom Modular Kit Biomedical Key features e Designed to meet the requirements for the NEXT dental survey protocol The Nationwide Evaluation of e Conforms to Center for Devices X Ray Trends NEXT dental and Radiological Health protocol has been issued to CDRH s
28. 3 phase one line cycle single phase Tube current Wide Dynamic Range From 4 mA to 3000 mA 3 phase 2 mA to 1500 mA single phase Note Generator settings will vary in waveform and distance Less than 1 kV effect for wide range radiographic filter pack covering 50 kVp to 150 kVp Specialty filter packs may have different characteristics Diagnostic X Ray Quality Assurance Instruments Biomedical Key features 35080M e New pocket size configuration e Non invasive technology eliminates the hazards of high voltage cables and need for bulky divider tanks e Auto ON OFF when connected disconnected e Optional filter packs enable testing in all modalities e Rh Rh measurement capability when 35080M Non Invasive kVp Divider is used with cadmium K Edge and linear mammo filter pack pair 35080M Non Invasive kVp Divider The 35080M Non Invasive kVp Divider quickly and accu rately measures kV for all modalities The unit checks both above and below table tubes and the direct kV values are displayed on either the 35050AT Dosimeter or the 199XRAY Medical ScopeMeter Derived kV can also be calculated using a storage oscilloscope The 35080M Non Invasive kVp Divider is highly portable and elimi nates the need for bulky and heavy high voltage divider tanks so compact in size that it fits into a shirt pocket A patented wide range filter pack is included with the 35080M Non Invasive kVp D
29. 5 dB cm MHz 0 05 dB cm MHz x A z Speed of sound 1540 m s Ordering information Contrast Anechoic 9 dB 6 dB 3 dB 6 dB and 9 dB 84 347 Gray Scale Ultrasound Diameters 2 4 mm 4 mm and 6 4 mm Phantom Depth Range 3 mm 1 cm to 6 cm 4 mm 2 cm to 9 cm 6 mm and 3 cm to 12 cm Dimensions LxWxH 13 cm x 35 cm x 17 cm 5 12 in x 13 78 in x 6 7 in Scanning well 1 cm deep Weight 10 45 kg 23 1b Ultrasound Quality Assurance 122 Ultrasound Elasticity QA Phantom The 84 349 Ultrasound Elasticity QA Phantom contains 10 mm and 20 mm diameter spheres of varying hardness relative to the background material The spheres are located at depths of 15 mm and 35 mm respectively and will appear isoechoic to the background using standard B mode imaging All materials are tested and a certification is provided listing the acoustic and elastic properties of each tissue Housed in a durable ABS housing with flexible scanning surface 84 349 is manufactured from Zerdinee a solid elastic polymer whose elastic proper ties can be controlled independently of its acoustic properties The phantom is a reliable and consistent elasticity reference tool useful for researchers sales demonstrations and quality assur ance testing Specifications Background Material Zerdine solid elastic water based polymer Freezing point O C 32 F Melting point above 100 C 212 F Speed of sound
30. 660 6 CT Ion Chamber 3 2 cm with UHF termination used with the 660 Electrometer 500 100 CT Jon Chamber 3 2 cm with triax BNC used with the 35040 ATD TRIAD and TRIAD TnT 500 200 CT Ion Chamber High Sensitivity 10 cm for multislice CT with triax BNC used with the 35040 ATD and other elec trometer dosimeters including TRIAD and TRIAD TnT 6000 100 CT Ion Chamber 3 2 cm with coax BNC for sig nal and banana plug for bias used with the 4000 8000 and RAD CHECK Plus Dosimeter 6000 200 CT Ion Chamber High Sensitivity 10 cm for multislice CT with coax BNC for signal and banana plug for bias used with the 4000 8000 and RAD CHECK Plus Dosimeter F The 76 430 Mini CT QC Phantom phantom is designed for routine monitoring of the consistency of all the major parameters of computed tomog raphy CT image quality and radiation dose Its unique compact design allows for unparalleled portability easy set up and reliable parameter determinations It is perfect for use by physicists technologists and service engineers The disc section consists of a 1 inch thick Lucite disc with a 6 inch diameter The six large holes are for the placement of inserts for evaluation of CT number consistency and evaluation of image resolution The four small holes are for inserting an ion chamber at different locations within the phantom Lucite inserts are provided to fill the four small holes when necessa
31. 9999 ms Pulses 1 pulse to 999 pulses Resolution Milliseconds 0 1 ms Pulses 1 pulse Diagnostic X Ray Quality Assurance Instruments Biomedical Optional accessories 35035 mA mAs Meter TNT 12000 Ansur Test Automation Software Plug in TNT 12000 X Ray Test Device Specifications Accuracy Milliseconds 1 or 0 5 ms Pulses 1 pulse Reproducibility Milliseconds 1 or 0 5 ms Elapsed time fluoro modes Pulses 1 pulse Average pulse rate pulsed fluoro Range O sec to 9999 sec Resolution 0 1 second Accuracy or 0 5 sec Range pps to 999 pps pulses per second Resolution pps Accuracy Pps Average pulse width pulsed fluoro Electrical specifications Battery Range O ms to 999 ms Resolution 0 1 ms Accuracy or 0 5 ms HVL Range Radio Fluoro modes 1 2 mm Al to 10 mm Al equivalent Mammo mode 0 2 mm Al to 0 6 mm Al equivalent Resolution Radio Fluoro modes 0 1 mm Al equivalent Mammo mode 0 01 mm Al equivalent Accuracy Radio Fluoro modes 10 or 0 2 mm Al equivalent Mammo mode 5 or 0 05 mm Al equivalent Battery type Lithium ion 3 7 V 4000 mAh Battery charge time Approx 5 hr Battery discharge time Approx 8 hr Battery cutoff voltage 2 75 V AC adapter Environmental specifications Operating temperature Input voltage 100 V ac to 240 V ac Input frequency 50 60 H
32. Alignment Utilizing New Radiographic Techniques Clinical Orthopedics June 1987 Ny Radiography During Double Contrast Barium Enema Examinations Radiology 149 3 December 1983 848 850 Radiography Fluoroscopy Phantoms and Accessories Butler P F Thomas A W Thompson W E Wollerton Feczko PJ et al Compensation Filtration for Decubitus Optional accessories Lead Plastic Filters 57 409 Breast Shields provides protection to the radiosensitive breast and lung parenchyma adjacent to the spine Fully adjustable may be used on the Filter Holder Assembly 57 426 with or without a compensation filter Consists of two 3 in x 3 in steel lead shields with magnetic tape on one side 57 408 Adult Gonad Shield Shamrock shaped insert has three overlapping lead circles each 0 50 inch cemented to clear plastic 57 444 Pediatric Gonad Shield For imaging children and the sacroiliac joints of adults Overlapping lead circles are 0 25 inch 57 430 Thin Buildup Filter Used with AP PA filters for patients with measurements from 14 cm to 25 cm Provides additional filtration in the cervical area to compensate for the added expo sure that may be needed in the thoracic lumbar area FLUKE o Biomedical Included accessories 57 402 57 405 AP PA Filter 57 406 Lateral Cervical Filter 57 407 Lateral Thoracic Filter 57 408 Adult Gonad Shield 57 409 Breast Shield Set 57 426 Filter Holder 5
33. At 60 f s 1 to 120 frames selectable IEC 61674 effective range at 1 resolution steps 96020C and 96035B Diagnostic Ion Chambers Energy range 96020C 30 kVp to 150 kVp 96035B 30 kVp to 150 kVp for diagnostic measurements 20 kVp to 50 kVp for mammographic measurements Nominal volume 96020C 150 cm 11 3 cm diameter by 1 5 cm thick active volume 96035B 15 cm 3 96 cm diameter by 1 22 cm thick active volume Nominal sensitivity 96020C H60 2 08 R C x 10 R C at 22 C and 760 mmHg optimized for low level image intensifier and cine measurements 96035B L100 2 0 R C x 10 R C at 22 C and 760 mmHg MV30 PTB Mammo Point 2 21 R C x 108 R C at 22 C and 760 mmHg flat energy response suitable for conventional diagnostic radiography and mammography Leakage current lt 10 fA under normal bias conditions 300 V Collection efficiency 96020C 95 at 2 000 R min 96035B 95 at 5 000 R min Diagnostic X Ray Quality Assurance Instruments Biomedical 96020C and 96035B e Very low leakage and low noise e Rugged mechanical construction e Ionization chambers are supplied with triaxial BNC connectors 96020C and 96035B Diagnostic Ion Chambers The 96020C and 96035B Diagnostic Ion Chambers are vented volume parallel plate air ionization chambers with side mounted BNC triaxial connectors The 96020C Ion Chamber has a nomi nal volume of 150
34. Calibration FLUKE o Biomedical Tol aVi ersmr l elem r l lela iilolal World class facility World class service Calibration Beam Specifications Molybdenum Rhodium Anode NIST Traceable Techniques Potential Filtration 7 mm Mo mm Rh Equivalent Beam Code Mo Mo 28 28 0 032 Mo Mo 35 35 0 032 0 39 Mo Rh 28 28 0 029 0 41 Rh Rh 25 25 0 029 0 35 Rh Rh 40 40 0 029 0 56 Mo Mo28x 28 0 030 2 0 63 Rh Rh 35x 35 0 029 2 0 898 PTB Traceable Techinques Equivalent Potential Filtration HVL Beam Code kV mm Mo mm Rh mm Al Al MV20 20 0 030 0 223 MV25 25 0 030 0 282 MV30 30 0 030 0 337 MV35 35 0 030 0 374 MV40 40 0 030 0 402 MV50 50 0 030 0 440 MV20 20 0 030 2 0 450 MV25 25 0 030 2 0 580 MV30 30 0 030 2 0 670 MV35 35 0 030 2 0 749 MV40 40 0 030 2 0 825 MV50 50 0 030 2 0 968 Service Center Repair Calibration US Fluke Biomedical 6045 Cochran Road Cleveland OH 44139 3303 Tel 440 498 2560 Toll free 800 850 4608 ext 2564 Email globalcal flukebiomedical com Service Center Repair Calibration Europe Fluke Biomedical Europe Science Park Eindhoven 5110 5692EC Son The Netherlands Tel 31 40 267 5435 Fax 31 40 267 5436 Email servicedesk fluke nl www flukebiomedical com service Service and Calibration Pu blications Biomedical Fluke Biomedical Radiation Oncology QA
35. It stands on two legs approximately 4 inches off the tabletop One leg is specially designed as a probe holder 9 55 kg 21 Ib Phantom Lead stop plate Copper attenuation plate Fluoroscopic image quality test object Dimensions LxWxH Weight 60 Radiography Fluoroscopy Phantoms and Accessories 07 601 and O7 800 Series Fluoroscopic System Resolution Test Tools and Flex Film Cassettes 07 601 Fluoroscopic System Resolution Test Tools The Fluke Biomedical Flouroscopic Resolution Tools are 7 5 inch square plastic plates that each have a 7 inch square area containing eight groups of copper or brass mesh screening in the following mesh size ranges 16 to 60 lines inch 30 to 100 lines inch or 60 to 150 lines inch The screens are arranged in an irregular rotation to permit discrete visualization of groups They can also be used to opti mize television system focus as well as mirror optics and image intensifier settings 07 800 Series Flex Film Cassettes The 07 800 Series Flex Film Cassettes are flexible vinyl x ray film holders that pro vide unsurpassed detail and resolution Unlike conventional cassettes Flex Film Cassettes contain no screen so you get direct exposure of the x ray film and a better image Flex Film Cassettes offer an ideal combination of firmness and flexibility for a variety of medical and industrial applications that s why they are the most
36. Quality Assurance FLUKE o Biomedical Key features e Reduces setup time by half e Simple to use e Complies with MQSA testing requirements as contained in the ACR Mammography QC Manual e Measurement can be quickly and easily repeated e Compression paddle rests on peg exactly 4 2 cm above the bucky no measurement of compression paddle height needed Stays firmly in place Adaptable for 18 cm x 24 cm 24 cm x 30 cm and magnification stand testing Image of test tool on top of bucky Image of test tool in bucky Ordering information 18 303 Mammography Collimation Assessment Test Tool includes one 1 7 cm peg and one 2 2 cm peg Specifications Labeling codes for positioning Labeling code Purpose 18 210 8000 View Markers for Mammography As stated in the American College of Radiology Mammography Quality Control Manual it is required that all mammography films are labeled to prevent misinterpre tation The 18 210 8000 View Markers provide the optimal solution to comply with ACR requirements The markers are radiopaque and each is equipped with an attached super hold suction cup Firm gentle pressure will hold the suction cup in place on the side of the mammog raphy unit Laterally Right R Left L Projection position Mediolateral oblique MLO Standard view Craniocaudal CC Standard view 90 Lateral
37. Quality Assurance Instruments Biomedical Key features e Entrance skin exposure measurements ESE e Fluoroscopy exposure examinations e Exposure checks radiographic mR mAs e Beam quality half value layer HVL e mAs reciprocity mA station checks plus many others depending on the remote external chambers used The American College of Radiology ACR recommends this type of product in their quality assurance program e Fast and easy use e Dual range for high and low dose rate fluoroscopy e Optimized for use with our 100 cm Image Intensifier Ion Chamber 06 524 3000 e Portable no ac power cords Optional accessories 89 525 Carrying Case holds RAD CHECK MICRO R and accessories 07 494 07 492 and 07 479 Whether using the Wide Range Mammographic or the Dental Digital kVp Meter these devices offer quick and accurate measurements of diagnostic x ray generator tube potential These instruments need no connection to the x ray generator Lightweight and rugged these meters are extremely C easy to use Simply place on the x ray table with the detector facing the x ray source With the beam s central ray centered on the detector an exposure is made and the reading appears immediately on the large easy to read liquid crystal display Unique features are provided to ensure maximum efficiency and accuracy Readings remain on display until the next exposu
38. an Fr E Eee par a a a ee a e pre n a em a m e ee puen mira ee Firei Pimes e E n A tiri briri ba rd aE a SO bma re es cee er ee ee ee a n one ee ee ee ee Diagnostic X Ray Quality Assurance Instruments Biomedical Key features e Automatically collects measurement results and places them in an Excel worksheet Automatically captures kV waveforms and charts them in an Excel worksheet Templates are provided for QA tests on radiographic fluoro scopic and mammographic x ray machines Templates may be modified to perform user specific tests and generate customized reports Allows complete remote control of the NERO mAx Complete online help speeds learning Compatible with Microsoft Windowse 2000 and above and Excel 97 2000 Biomedical System requirements Windows 2000 and above Microsoft Excel 97 2000 F One serial port COM1 through The NERO mAx menu provides an interface for the user to remotely control the NERO mAx and COM4 retrieve radiation and kV waveforms A description of each menu option follows Select mode Selects the NERO mAx measurement mode This allows the user to select the correct measurement mode for the template in use For instance the radio mode is selected when using the radiographic template the mammo mode is selected when using the mammographic template and the fluoro mode is selected when using the fluoroscopic template Controls Retrieve r
39. be inserted properly The W AI filter card and the Mammo filter card are clearly labeled to the x ray tube targets for which they are calibrated Diagnostic X Ray Quality Assurance Instruments Key features e Non invasive evaluation of radiation outputs e 100 kHz sampling speed captures data from the most difficult machines e 0 5 kV or 1 accuracy from 22 kV to 160 kV e Measures kVp average kV effective kV peak time expo sure or rate mA or mAs HVL exposure frame and mAs frame e Displays R or Gy e Excel Add in includes MQSA Rad and Fluoro templates e RS 232 computer interface e Enhanced dental capabilities External chambers External ion chambers for CT mammographic image intensifier tube and special radiographic applications are available Chamber calibration factors can be stored in the NERO mAx for direct readout of measurements The Excel Add in acquires measured data and waveforms directly into an Excel spread sheet to maximize flexibility for report generation Biomedical Real time CT Th Pali BI ky E mPa Sie Easy Flow menu Radio screen 24 8 kip deg 24 3 kw Eit 27 3 Wy Peake Moe NENS Tomeer cose Easy Flow menu Mammo screen 75 4 kp avg 0 159 mma 71 1 ky Eit 0 m nipulbss B0 8 wren TIF utpuss MEDE TYPE gt SENS ESS Easy Flow menu Pulsed Fluoro display 74 1 p Awg 102 1 maeatrame T2 7 ky EN 359 3 ent ager 74 8 Wv Paak 30 5 mas
40. body resolution and noise measurements when positioned on the main tank Inner and outer resolution values are easily determined CT SSP insert 76 412 The CT SSP Slice Sensitivity Profile Point Response Phantom can be used as a stand alone phantom or as an insert with the AAPM CT Performance Phantom The AAPM CT Performance Phantom meets the guidelines in AAPM Report 1 for Performance Evaluation and QC of CT Scanners The AAPM CT Performance Phantom is described in the report by the AAPM Task Force on CT Scanner Phantoms Optional accessories The acrylic and closed cell foam ball bearing size is 0 01 in diameter is 7 5 in width is 3 5 in and 76 411 External Whole Body weight is 0 825 1b Resolution and Noise Ring Low Contrast CT Resolution Insert 76 421 Sari CT SSP Point Response antom The insert consists of an almost water equivalent plastic disc 201 mm x 25 mm thick protected 16 421 Low Contrast CT on both sides by clear plastic The resolution targets are a series of water filled holes from 2 5 mm IR d onraz to 7 5 mm in in 0 5 mm steps For each target size the center to center distance between holes esolution Insert is twice the hole diameter to ensure meaningful resolution testing The insert s 25 mm thickness eliminates alignment problems Dimensions are 201 6 cm x 32 5 cm thick Weight is 1 1b Dimensions xD 21 59 cm x 39 37 cm 8 5 in x 15 5 in Weight 7 84 kg 17 25 1b Orderin
41. by counting these targets See Figure 4 Radiography Fluoroscopy Phantoms and Accessories Biomedical a 1 i Figure 4 Working thickness range Three examples of white clipping and two examples of black clipping Figure 6 Example of typical dosimetry measurement Geometry Dosimetry center is always 25 mm below bottom of phantom Biomedical How does the NEMA Cardiology Phantom actually work oF The field size plate is placed on top of the phantom A second plate with a centered radiopaque dot is placed in the base The imaging gantry is adjusted until the cross wires intersect the approximate center of the disk See Figure 7 Fluorographs A and B demonstrate acceptable alignment of the NEMA phantom In fluorograph A the spatial resolution test plate and several of the low contrast detectability targets are shown Both lines cross at the dot Fluorograph B shows both lines crossing at the dot The test plates have been removed Fluorographs C and D demonstrate poor alignment of the NEMA phantom In fluorograph C the spatial resolution test plate and several of the low contrast detectability targets are also seen in this image The intersection of the two lines is outside the dot Fluorograph D shows the intersection of the two lines outside the dot The test plates have been removed Figure 7 Alignment Tools NEMA Base with both lower dot and upper cross align NEMA Base with bot
42. consists of an 8 5 inch diameter acrylic tank con taining a beam width insert a spatial resolution and linespread block a high contrast insert and a means for inserting align ment pins and or TLD holders Additionally a 0 25 inch thick Teflon band positioned at the base of the tank and concentric to the 8 inch internal diameter simulates human bone Attached to the base of the tank is a low contrast section with reseal able cavities from 1 in to 0 125 in diameter which can be filled with a diluted dextrose or other appropriate solution to provide a low contrast media The optional external resolution and noise ring slides snugly over the outside diameter of the tank allowing whole body scanner systems to be evaluated Made of acrylic Dimensions ODxIDxL 8 5 in x 8 in x 12 75 in Resealable with fill and drain ports Low contrast detectability block is attached to base Linearity and contrast insert Dimensions ODxL 7 5 in x 2 5 in Contains 1 inch diameter contrast pins of polyethylene acrylic polycarbonate polystyrene and nylon Density values polyethylene 0 95 gm cc polystyrene 1 05 gm cc nylon 1 1 gm cc acrylic 1 19 gm cc polycarbonate 1 2 gm cc Note The contrast pins in each AAPM CT Performance Phantom are identical in density to the contrast pins of similar material in every other Fluke Biomedical CT Phantom For example the nylon pin in every CT Phantom we manufacture has the sam
43. detail and other image quality experiments Developed by M A 0 Thijssen Ph D K R Bijkerk MSc and J M Lindeyer BSc Project Quality Assurance in Mammography QAMAM Department of Diagnostic Radiology University Hospital St Radboud Nijmegen The Netherlands 96 Mammography Quality Assurance Biomedical A line pattern has been engraved onto the Plexiglas cover and treated with paint containing aluminum The x ray image will show a number of squares ordered in 16 columns and 16 rows with the disc diameter shown for each row and the disc thick ness for each column The 18 227 CDMAM Phantom includes a set of four Plexiglas plates which are used for the simulation of different breast thicknesses The plates are 10 mm thick and the same dimen sions as the phantom The plates are marked in one corner for identification of the configuration of Plexiglas and phantom in an x ray image The phantom and Plexiglas plates match the stan dard mammography film size 18 cm x 24 cm Under standard mammography exposure conditions Mo anode 30 pm Mo filtration 28 kVp the phantom has a Plexiglas equivalent thickness of 10 mm The actual attenuation of the CDMAM Phantom depends on the configuration of the phantom and Plexiglas plates The effective energy of the phantom plane will be higher when more Plexiglas is added to the top and bottom of the phantom Application To make an x ray image the CDMAM Phantom should be posi
44. dia 0 0091 in 0 0126 in 0 018 in lines inch 0 025 in 12 16 0 035 in 20 24 0 049 in 30 40 0 068 in 50 60 1 in gap The Nationwide Evaluation of X Ray Trends NEXT fluoroscopy protocol has been issued to provide guidelines for quality control procedures for diagnostic fluoroscopy In order to perform these proce dures a suitable phantom was developed the 07 649 CDRH Fluoroscopic Phantom In a survey of fluoroscopic facilities for the NEXT pro gram it was determined that a substantial proportion of facilities could not visualize low contrast test objects this strongly suggests image quality problems Measurements for this survey were performed using the 07 649 CDRH Fluoroscopic Phantom In addi tion to air kerma rate free in air measurements imaging performance was assessed using the Fluoroscopic Image Quality Test Object included with phantom The phantom also contains a lead stop plate and copper attenuation plate By using the 07 649 CDRH Fluoroscopic Phantom doses at fluoroscopy can be reduced and fluoroscopic image quality Biomedical Key features e Conforms to Center for Devices and Radiological Health CDRH specifications e This phantom is now required in order to comply with QC tests recommended in the ACR s Barium Enema QC Manual e Recommended in AAPM Report No 60 Instrumen tation Requirements of Diagnostic Radiological Physicists e Optimized for both unde
45. eee Fibers Al203 Specks Masses A 0 93 mm nylon fiber E 0 54 mm speck I 0 25 mm thickness mass B 0 74 mm nylon fiber F 0 32 mm speck J 0 5 mm thickness mass C 0 54 mm nylon fiber G 0 24 mm speck K 0 75 mm thickness mass D 0 32 mm nylon fiber H 0 2 mm speck L 1 mm thickness mass Designed by Carol Mount R T R M and Joel E Gray Ph D Department of Diagnostic Radiology Mayo Clinice Rochester MN 55905 Manufactured under licensing agreement with Mayo Foundation for Medical Education and Research Mammography Quality Assurance Digital image demonstrating image evaluation insert Key features e The fast easy way to test image quality on digital biopsy mammography units and qualify for ACR accreditation e Accepted by the ACR for use in its Stereotactic Breast Biopsy Accreditation Program e One exposure is all you need e The phantom contains test objects that are similar to those found in the Mammo graphic Accreditation Phantom specified by the ACR e The extended top edge of the phantom allows ease of positioning on recumbent biopsy units e The phantom s small size allows it to be imaged in its entirety in a single exposure when used with a digital biopsy unit e Enables you to determine if the images are similar to or better than screen film Biomedical 94 18 251 2000 The 18 251 2000 Contrast and Resolution Mammography Phantom is designed with an
46. exposing the meter Features nclude auto reset and auto power off There is no need to adjust the light field to a square phantom before making an expo sure No time is wasted waiting for films to be developed The pocket sized DXR gives an objective reproducible and immediate read out Dimensions WxDxH 23 cm x 23 cm x 1 6 cm 9 in x 9 in x 0 625 in Weight 2 27 kg 5 1b Range Mammo 30 kVp 50 kVp 70 kVp 100 kVp gt 100 mA gt 200 mA gt 100 mA gt 100 mA Dimensions WxDxH 15 mm x 30 mm x 145 mm 0 59 in x 1 18 in x 5 71 in Weight 75 gr 2 6 oz Radiography Fluoroscopy Phantoms and Accessories Biomedical Key features e Conforms to Report 15 by the American Association of Physicists in Medicine AAPM e Checks contrast range resolu tion linearity uniformity amplifier dynamic range registration accuracy and subtraction effectiveness Provides easy to interpret results Quantitatively measures high and low contrast spatial resolution Retaining hasps ensure a tight fit between the step blocks for reduced motion artifacts Specially designed stop on the end of the slot blocks improves the positional accuracy of the insert material during image acquisition and This 76 710 Digital Subtraction Angiography DSA Phantomt reduces the number of DSA conforms to the recommendation in Report No 15 by the frames that must be acquired American Association of Physicist
47. exposure 3rd waveform value represents the average mA for the 3rd 50 milliseconds of exposure Reset Auto LCD update optional manual reset Dynamic range 10 mA to 2000 mA 0 1 mAs to 999 9 mAs 1 ms to 6 535 sec Accuracy mAs 0 1 mAs or 1 whichever is greater mA 1 0 mA or 0 5 whichever is greater Time 1 ms or 1 whichever is greater Operating temperature 15 C to 35 C 59 F to 95 F Power requirements One 9 V battery Typical battery life gt 40 hours Size 10 16 cm x 16 51 cm x 0 84 cm 4 in x 6 5 in x 0 33 in Weight 0 28 kg 0 625 1b Diagnostic X Ray Quality Assurance Instruments Key features Biomedical An intelligent meter that measures mAs exposure time and mA all at the same time Provides mA waveform information At a button press the O7 MAS5 meter ignores the first 10 milliseconds of exposure AC and DC inputs A diagnostic power up sequence to indicate opera tional status Auto LCD update Optional manual reset Automatic power down when meter is not used for more than five minutes Displays when an exposure is detected Low battery indication The 660 X Ray and CT Exposure Measurement Instrument is the optimum choice for flexibility in x ray and computed tomography CT exposure measurement The 660 consists of a readout carrying case and choice of four optional ion chamber based probes with built in calibrations allow
48. features e Displays minimum maximum readings e Hold freeze function e Auto shut off e Battery eliminator jack for a 9 V dc converter e Checks film processor solution temperatures quickly and accurately e Large easy to read backlit digital display of temperature in Centigrade or Fahrenheit e Accuracy 0 5 e State of the art detachable immersion probe saves time and allows use of multiple probes with one display unit Optional accessories 07 403 Immersion Probe 07 401 Waterproof Probe will not be damaged in chemistry or water Included accessories High impact plastic case Ordering information 07 402 Portable Digital Thermometer with one probe FLUKE o Biomedical Key features e Large illuminated surface e Density range is O D to 4 5 D e Three apertures 1 mm 2mm and 3 mm e RS 232 interface available e Includes a five step optical density tablet Digital Densitometer The 07 424 Digital Densitometer is an easy to use precision instrument that quickly mea sures the optical density of film And with its optional RS 232 interface you have the capability to automatically transfer the data to a computer for storage and retrieval Constructed of rugged steel and compact enough to fit on any crowded worktable it offers exceptional accuracy 0 02 optical density The optical density value is dis played in bright LED numerals on the detector arm The sample table is 6 125 in x 10 5 in
49. features the 35050AT dosimeter a technologically advanced microprocessor controlled x ray radiation dosimeter The kit also includes ion chambers and test stand triaxial coaxial cable ac adapter HVL filter set RS 232 interface cable with adapters customization software instruction manual CD and lightweight carrying case 10500AT includes all of the components from the 10100AT in addition to the 35080M non invasive kVp divider and 37617 wide range filter pack 50 kVp to 150 kVp for quick and accu rate kV measurement 10500AMT is equipped with all the components from the 10500AT as well as the 35035 mA mAs meter and CA 23 universal test lead kit allowing engineers to accurately measure mAs and fluoroscopic mA for diagnostic radiographic and fluoroscopic imaging equipment Diagnostic X Ray Quality Assurance Instruments Key features e Bright display with direct readout in user selected units Image intensifier measure ments at 0 1 yR and 0 1 uR s resolution cine in pR frame Expanded kVp and exposure time measure ment capabilities Simplified controls include autoreset autoranging automatic offset and drift compensation automatic power down and automatic pressure and temperature correction Optional TRIAD toolkit for Excel for remote operation waveform capture and calibration Multiple self checking features to reduce testing time Battery powered with auto power down feature to extend battery life Automati
50. fibers A1203 Specks Masses thickness 1 1 56 mm 7 0 54 mm 12 2mm 2 1 12 mm 8 0 4mm 13 1 mm 3 0 89 mm 9 0 32 mm 14 0 75 mm 4 0 75 mm 10 0 24 mm 15 0 5 mm 5 0 54 mm 11 0 16 mm 6 0 4 mm 92 Mammography Quality Assurance In the past there was not an easy way to compare the image quality of conventional and digital biopsy mammography units because the field of view on the digital system is typi cally much smaller than the 24 cm x 30 cm field of view on conventional mammography units In order to image the h Mammographic Accreditation Phantom specified by the American College of Radiology ACR on the biopsy units the Phantom with image evaluation insert user has to move the phantom to various positions in order to obtain four separate images to be sure all objects were imaged This is a very inconvenient time consuming task The small size of the 18 250 Digital Stereotactic Breast Biopsy Accreditation Phantom phantom permits fast easy comparison of conventional and digital image quality because you can attain an image of the entire unit in a single exposure The objects are some of the same ones found in the Mammographic Accreditation Phantom specified by the ACR so it makes comparison of the two imaging systems easy Phantom body Material Cast acrylic base block Dimensions WxDxH 6 05 cm x 6 2 cm x 3 71 cm 2 38 in x 2 44 in x 1 46 in Weight 1 2 kg 8 7 oz Wag insert
51. filters that block the collimator light field In addition CLEAR Pb fil ters are only one fifth as heavy as aluminum filters And they eliminate the use of gradient speed intensifying screens CLEAR Pb filters are made of lightweight plastic that is 30 lead by weight A unique quick stik magnetic mounting system plus a filter holder that slides into the collimator tray ensure that the filter is held firmly in place It also permits instant repositioning as the area and or degree of filter coverage changes Full Spine Scoliosis Filter Tested and proven in FDA and specialized radiography studies enables scoliosis radiography with more diagnostic detail and less radiation exposure FLUKE o Biomedical Key features e Improve image quality e Filters are 30 lead by weight e Reduce the need for multiple exposures e Ensure a more uniform image density e Reduce patient exposure by selectively attenuating the x ray beam e Lightweight easy to use e Mounts to any collimator e Collimator light field is never blocked Single exposure spinal radiographs the radiograph at left was obtained without a CLEAR Pb filter Notice burnout in cervical and thoracic areas At right is radiograph obtained with a CLEAR Pb AP PA filter Note uniform density throughout the spinal column 57 4 Series CLEAR PB Compensation Filters Biomedical
52. is actually 16 5 inches in order that extraneous light is eliminated when standard 14 in x 17 in film is inserted in the roller gravity grip Qverall recessed fixture dimensions including recessed trim length and height are each 3 inches greater than surface mounted dimensions Replacement parts Sra we HERA L ER Film Handling and Storage 77 FAMS Film Activated Micro Switch 71 CS REPL Cluster Switching 71 MS REPL ON OFF Master Switch 71 LC REPL Line Cord and Plug Assembly 77 REPL VP Translucent Viewing Panel per panel 77 HGP REPL Hospital Grade Plug 77 BAL 200 Ballasts Techline 200 Series 71 BAL 300S Ballasts Techline 300 Series single intensity 71 BAL 300D Ballasts Techline 300 Series dual brightness 71 BAL 400S Ballasts Techline 400 Series single intensity 71 BAL 400D Ballasts Techline 400 Series dual brightness Re mount retrofit kits 71 REC SUR Recess to Surface per panel 77 SUR REC Surface to Recess per panel Optional accessories 71 FAS Film Activated Switch 71 MS On Off Master Switch 77 DB300 Hi Low Dual Brightness Switch 300 series includes FAS 71 DB400 Hi Low Dual Brightness Switch 400 series includes FAS 77 HGP Hospital Grade Plug 77 HW Surface Mount Hard Wired 77 HF Handle and Non Skid eek Diagnostic Viewing Center per system 71 DVC11 to 77 DVC44 71 DVC55 and 77 DVC66 71 DVC90 with Bright Spot capability 771 DVC91 without Bright Spo
53. number dates prone position x ray units Minimum number of objects detected Minimum detectability score 24 49 Phantom material Plexiglas Dimensions WxDxH 6 27 cm x 6 27 cm x 6 27 cm 2 47 in x 2 47 in x 2 47 in Weight 0 58 kg 1 2 1b Column number Object depth Typical contrast at mammographic energies 1 0 853 mm 0 033 in 6 6 2 0 533 mm 0 021 in 4 2 3 0 332 mm 0 013 in 2 6 4 0 208 mm 0 008 in 1 7 5 0 129 mm 0 005 in 1 6 0 08 mm 0 003 in 0 65 7 0 05 mm 0 002 in 0 41 Object diameter Row number Object diameter Row number Object diameter 1 4 292 mm 0 169 in 5 0 513 mm 0 02 in 2 524 mm 0 099 in 6 0 302 mm 0 011 in 1 485 mm 0 058 in 7 0 177 mm 0 007 in 0 873 mm 0 034 in 2 3 4 Mammography Quality Assurance Biomedical Biomedical Key features e Helps identify objects with very low contrast and very small diameter Compatible with full field analog and digital units Compares of image qual ity with various screen film combinations Evaluates conventional digital and stereotactic modalities Determines the optimum exposure technique e g by variation of tube potential Compares image quality at various object thicknesses by variation of the amount of Plexiglas at a fixed density The 18 227 CDMAM Contrast Detail Mammography Phantom was develop
54. of active length Beam orientation Normal to chamber axis Leakage current 300 V collection potential Less than 10 A at 10 min polarization time Intensity limits Continuous beam 31 6 R sec 1 recombination loss Pulsed beam 15 8 mR pulse 1 recombination loss Collection time 0 478 mSec Cable length 0 9 m 3 ft Operating voltage 300 V Detector type Vented air ion chamber Volume 3 2 cc Sensitive length 10 cm Chamber material Polystyrene Chamber inside diameter 6 4mm Chamber wall thickness 54 mg cm Electrode material Aluminum Sensitivity 10 Recm nC nominal Standard calibration 100 kVCP 5 5 mm Al HVL NIST Tech M100 Response uniformity along axis 3 over central 90 of active length Beam orientation Normal to chamber axis Phantom adapter OD 1 27 0 04 cm 0 5 0 015 in Leakage current 300 V collection potential Less than 1013 A at 10 min polarization time less than 1014 A at 2 hour polarization time Intensity limits Continuous beam 4 86 kR min 1 recombination loss Pulsed beam 51 5 mR pulse 1 recombination loss Maximum pulse repetition 3 3 kHz rate Cable length 0 9 m 3 ft Operating voltage 300 V CT Quality Assurance FLUKE o Biomedical 10 cc high sensitivity ion chamber Va SS n cr 3 2 cc ion chamber a a Ordering information
55. of exposures to be made without used intervention At the time Auto Reset is clicked the TRIAD will be set up for an exposure Filter packs Selects the filter pack to use for kVp measurements Chambers Selects the ion chamber to use for exposure measurements Units Selects the unit to use for exposure measurements Download waveform The Waveform button is enabled after an exposure is made and before the TRIAD is set up for another exposure When the Waveform button is pressed a dialog box prompts for the start and end times for the waveform chart allowing the user to specify any portion of the kV waveform The default start and end times are for the complete waveform The waveform data is then placed in the active cell in the active workbook Help Templates Three templates are also provided with the TRIAD Toolkit for Excel a radiographic template a mammographic template and a fluoroscopic template Each template includes a help worksheet with detailed instructions for its use Opens the TRIAD Toolkit for Excel Instruction Manual The TRIAD radiographic template Is used to perform the following radiographic tests reproducibility kVp accuracy timer accuracy linearity and beam quality The TRIAD mammographic template The TRIAD fluoroscopic template May be used to perform mammography tests required for ACR and MQSA Measured data from the 35050A Dosimeter may be automatically collected in the follo
56. one sphere each of the following diameters 2 4 mm 3 2 mm 4 mm 4 8 mm 6 3 mm and 9 5 mm These diameters were chosen to encompass the full range of clinically significant lesions The disk can also be placed at the end of the phantom when axial scanning detectability testing is desired fee Disk with embedded targets CT Quality Assurance 776 424 4156 Nested CT Dose Phantom Kit for Pediatric Adult Head and Body The innovative nested CT Dose Phantom can be used with any computed tomography CT system designed to image pedi atric and adult head and body Each phantom segment can pro vide separate dose information When performing dose profile measurements the dose phan toms allow the user to collect information for the maximum minimum and mid range value of the nominal tomographic sec tion thickness This essential phantom kit con sists of three parts an adult body phantom an adult head phantom that doubles as a pediatric body phantom and the new pediatric head phantom nested together for easy storage and convenient transport All are made of solid acrylic with diameters of 32 cm 16 cm and 10 cm respectively Each part contains four probe holes FLUKE o Biomedical Key features e Uniquely designed for pedi atric and adult computed tomography dose index CTDI in a lightweight 20 kg 44 1b total package e Can be used with new multi det
57. phantom Dimensions Lx 15 cm x 10 cm Weight 1 3 kg 3 1b 3 nested phantoms Weight 15 kg 33 lb Weight 716 419 4150 Body phantom 14 5 kg 32 lb Head phantom 3 6 kg 8 1b Weight 716 414 4150 Body phantom 14 5 kg 32 1b Head phantom 3 6 kg 8 Ib Pediatric head phantom 1 3 kg 2 85 Ib CT Quality Assurance 716 424 4150 Nested CT Dose Phantom Kit for Pediatric Adult Head and Body including carrying case without wheels and pull handle 716 414 4150 CT Dose Phantom Kit for Adult Head and Body including carrying case 76 419 4150 CT Dose Phantom Kit for Pediatric Adult Head and Body including carrying case with wheels and pull handle 76 419 CT Pediatric Head Dose Phantom with five plugs 76 414 CT Head Dose Phantom with five plugs 76 415 CT Body Dose Phantom with five plugs 110 Specifications 10 cc high sensitivity CT lon Chambers CT lon Chambers Detector type Vented air ion chamber Volume 10 1 cc Sensitive length 10 cm Chamber material Chamber outside diameter Acrylic PMMA 12 7 mm 0 4 mm 0 5 in 0 015 in Chamber inside diameter 11 44 mm 0 45 in Chamber wall thickness 77 mg cm Electrode material Aluminum 1100 Sensitivity 3 2 Recm nC nominal or 0 3 nC Standard calibration 100 kVCP 5 5 mm Al HVL NIST Tech M100 Response uniformity along axis 3 over central 90
58. phantom range in size from those that should be visible on any system to objects that will be dif ficult to see in the best mammographic systems The 18 222 includes a 30x hand held microscope and mammography QA documents for recording image evaluations and scores 25 adipose Line pair target 1 20 Ip mm Calcium carbonate specks 2 0 13 3 0 165 4 0 196 5 0 23 6 0 275 7 0 4 8 0 23 9 0 196 10 0 165 11 0 23 12 0 196 13 0 165 Step wedge 1 cm thick 14 100 gland 15 70 gland 16 50 gland 17 30 gland 18 100 gland Nylon fibers 19 1 25 mm 20 0 83 mm 21 0 71 mm 22 0 53 mm 23 0 3 mm Hemispheric masses 24 4 76 mm thick 25 3 16 mm thick 26 2 38 mm thick 75 glandular 27 1 98 mm thick 28 1 59 mm thick 29 1 19 mm thick 30 0 9 mm thick Optical density 31 reference zone Edge beam 32 localization target Material Epoxy Dimensions WxDxH 18 5 cm x 12 5 cm x 4 5 cm 7 28 in x 4 92 in x 1 77 in Weight 1 kg 2 2 1b References Skubic S E Fatouros P P Absorbed Breast Dose Dependence on Radiographic Modality and Technique and Breast Thickness Radiology 61 1986 263 270 Fatouros P P Skubic S E Goodman H The Development and Use of Realistically Shaped Tissue Equivalent Phantoms for Assessing the Mammographic Process Radiology 32 1985 157 Mammography Quality Assurance Key fe
59. remote sensor can also be used when placement of the Digital X Ray Pulse Counter Timer in the beam is ques tionable such as in a Panorex dental x ray unit Optional accessories 07 453 2000 Remote Sensor with 10 ft cable 88 453 Oscilloscope Leads 89 453 Carrying Case Ordering information 07 453 Digital X Ray Pulse Counter Timer The 07 487 Dual Range Digital mAs Meter allows service per sonnel to check and adjust the mA settings of x ray generators This easy to use instrument is calibrated directly in mAs thus eliminating the need for the calculations typically required with more complicated and expensive equipment The digital mAs meter is very sensitive It can measure incre ments of 0 1 mAs It has a low range of O mAs to 199 9 mAs push a button and the range expands to O mAs to 1999 mAs The greatest use for the 07 487 mAs meter is in calibrating the high current short time station where a conventional mAs meter is verifying the generator accuracy to set all mA stations and check C precluded by tube ratings The instrument can be used after that phototiming error does not exceed the limits of good prac tice To use simply connect the cable to the x ray generator and make the required exposure The mAs reading appears instan taneously on the four digit LCD A display indicator warns of the need for battery replacement Ranges O mAs to 199 9 mAs over
60. targets 4 Diameter of targets 2 mm 4 mm 6 mm and 8 mm Depth of targets 2 cm 4 cm 6 cm and 8 cm Contrast of targets 15 dB relative to background Phantom dimensions WxDxH 19 cm x 20 cm x 14 cm 7 5 in x 8 in x 5 5 in Weight 9 1 kg 20 lb with case Carrying case WxDxH 46 cm x 38 cm x 43 cm 18 in x 15 in x 17 in Ultrasound Quality Assurance The 84 342 General Purpose Urethane Ultrasound Phantom offers a reliable medium which contains specific known test objects making it more accurate than random scan nable materials The phantom enables repeatable qualita tive assessment of ultrasound scanner performance over time The phantom is constructed from a proprietary urethane matrix housed within a rigid PVC container with three separate scanning windows It allows for depth of penetration uniformity distance calibra tion resolution and lesion detectability assessment The three scanning surfaces also provide the user with the ultimate in versatility simplicity and ease of use The scanning wells permit either water or gel to be used as an acoustic coupling agent Phantom material Proprietary urethane matrix Attenuation coefficient 0 5 dB cm MHz 0 05 dB cm MHz at 5 MHz Speed of sound 1430 m s 10 m s at 20 C Scanning surfaces Number 3 Depth of scanning wells 2 cm Housing material White PVC Vertical plane targets Number of groups 1
61. the bottom sec gray finish It comes with a tion of either a a painted lower panel to cover the open area or 7 ft switch cord and can be b a lower panel with a bright spot capability as shown above table or wall mounted bright spot NOT included All DVC products may be wall or counter top mounted Diagnostic Viewing Center DVC 71 DVC11 1 over 1 angled 14 25 in x 41 75 in 71 DVC22 2 over 2 angled 28 25 in x 41 75 in 71 DVC33 3 over 3 angled 42 25 in x 41 75 in 71 DVC44 4 over 4 angled 56 25 in x 41 75 in Optional accessories 71 DVC55 5 over 5 angled 70 25 in x 41 75 in 77 101HL High Intensity TI DVC66 6 over 6 angled 84 25 in x 41 75 in Bee leliaye DVC Corner System pi 71 DVC90 Corner kit with bright spot capability amd bright spot not included 71 DVC91 Corner kit without bright spot capability fc CORNER SraTee Top View jet 475 Po ae T 120 88 Film Handling and Storage Biomedical 77 201VR to 77 266VS Key features e Thin 3 375 inch profile e Sturdy steel construction e FLEXI GRIP handles all film thicknesses wet or dry e Continuous bottom film ledge e Minimal 1 8 inch separation Available in configurations from ee a single 14 in x 17 in panel up to a six over six the MAXANT MVP Illuminator is a two between tiers of two tiered lamp light source that emits fixtures approximately 2000 NITS of e Shatterproof translucent panel
62. to 65 keV Cable 4 5 m 15 ft Chamber dimensions 10 2 cm x 10 2 cm x 1 4 cm 4 in x 4 in x 0 54 in thick 6000 529 3 3 cm Energy response within 5 from 0 2 mm to 5 0 mm Al HVL 16 kVp to 90 kVp Cable 4 5 m 15 ft Chamber dimensions 4 cm x 1 5 cm thick This chamber meets the needs of the MQSA for an external transparent chamber 6000 530B 150 cm Energy response 10 from 1 8 mm to 10 mm Al HVL Cable 3 m 10 ft Chamber dimensions 15 9 cm x 20 6 cm x 1 6 cm 6 26 in x 8 in x 0 63 in 6000 532B 400 cm Energy response 5 from 32 keV to 662 keV Cable 3 m 10 ft Chamber dimensions 15 9 cm x 20 6 cm x 1 6 cm 6 26 in x 8 in x 0 63 in 6000 100 and 500 100 CT 3 2 cm Energy response 5 from 1 mm to 10 mm Al HVL Cable 0 9 m 3 ft Sensitive length 10 cm 4 in chamber inside 6 4 mm 0 25 in 6000 200 and 500 200 CT 10 cm for multislice CT Energy response 5 from 1 mm to 10 mm Al HVL Cable 0 9 m 3 ft Sensitive length 10 cm 4 in Chamber inside 11 44 mm 0 45 in Diagnostic X Ray Quality Assurance Instruments Specifications Measured quantity Kilovoltage Measured during the first 480 ms of exposure NERO mAx X Ray Test Device KVp Avg KV Eff KV Peak Accuracy 0 5 KV or 1 Reproducibility 0 5 kV or 1 Range Target Filter Range Filtration W Al 30 kV to 60 kV 50 kV to 100 kV
63. widely used flexible film cassettes in the industry Flex Film Cassettes are the best choice for QC testing of imaging equipment They are ideal for use with such test tools as the Mini CT QC Phantom all X Ray Test Patterns and all Focal Spot Imaging Test Tools as well as many others Specifications 07 601 Dimensions WxDxH 19 cm x 19 cm x 0 3 cm 7 5 in x 7 5 in x 0 35 in Weight Weight 0 225 kg 0 5 1b 07 800 Series Radiography Fluoroscopy Phantoms and Accessories FLUKE o Biomedical Key features 07 601 e For resolution checks of fluo roscopic imaging systems 07 800 e Convenient to use an align ment grid is printed on one side Easy to load they fit easily around contoured items Durable use them again and again Resistant to moisture and dirt they re easy to clean Available in custom sizes cassettes have been manufac tured in sizes up to 68 inches long Metric sizes are also available on special order Ordering information 07 601 Fluoroscopic Resolution Tool 16 60 mesh 07 619 Fluoroscopic Resolution Tool 30 100 mesh 07 618 Fluoroscopic Resolution Tool 60 150 mesh 07 601 1414 Fluoroscopic Resolution Tool 16 60 mesh 14 in x 14in 07 800 5007 Flex Film Cassette Byaah dq Hf shal 07 800 8010 Flex Film Cassette 8 in x 10in 07 800 8012 Flex Film Cassette fs aia a 2 shay 07 800 1012 Flex Film Cassette 10 in x 12 in 07 800 1417 Flex Film Cassette 1
64. with a 4 75 in x 5 5 in illuminated section It will accommodate film up to 14 in x 17 in and provides ample room for positioning any selected area under the detector The detector is a hermetically sealed silicon photodiode The detector lamp is at full brilliancy only during the actual measure ment thus preventing heating problems and ensuring very long lamp life with minimum wavelength shift or other degradation When necessary the lamps are easily replaced The densitometer includes a five step optical density tablet CE Specifications Density range ODto 4 5D Accuracy 0 02 density Reference tablet supplied Response time Two seconds at 3 density Zero drift Negligible Apertures supplied 1 mm 2 mm and 3 mm D Anodized aluminum Throat 21 cm length 8 2 in Easily measures to center of 35 6 cm x 43 cm 14 in x 17 in film Illuminated table 12 cm x 14 cm 4 75 in x 5 50 in Diameter of aperture holder area obscured 0 73 in Spectral response 5000 A to 5500 A peak of bell shaped curve Detector illumination Incandescent lamp with spectral compensation filter Lamp is at full brilliancy only during measurement Table illumination Four 37 low voltage wedge base lamps Digital readout Three 0 4 inch high light emitting diode LED numerals on detector arm Detector Hermetically sealed silicon photodiode Zero control Allows wide range adjustment
65. x 5 0 cm x 8 75 cm 2 in x 2 in x 3 50 in Weight 0 35 kg 0 78 1b Please refer to charts at the right for Miliamp current and signal Input limit specifications for the 35035 mA mAs Meter Milliamp seconds mAS Range Resolution Input impedance 200 mAs 0 1 mAs 10Q 2000 mAs 1 0 mAs 1Q Current mA Does not include fuse resistance Also does not include effect of bridge rectifier present when unit is set for ac specifications Range Resolution Input impedance 20 mA 0 01 mA 100 Q 200 mA 0 1 mA 10 Q 2000 mA 1 mA 1Q Signal input limits Does not include fuse resistance Also does not include effect of bridge rectifier present when unit is set for ac specifications Function Range Max input limit mA OFF Input shorted 2 0 A maximum fuse protected 20 250 mA for 30 s 200 1 0 A for 30 s 2000 2 0 A maximum fuse protected mAs 200 1 0 A for 30 s 2000 2 0 A maximum fuse protected Limits set by power dissipation rating of shunt resistors Diagnostic X Ray Quality Assurance Instruments 10100AT 10500AT and 10500AMT TRIAD TnT X Ray Field Service Optional accessories All Kits 500 100 CT Ion Chamber 3 2 cm 500 200 CT Ion Chamber High Sensitivity 10 cm for Multislice CT 07 434 Ultra high Purity HVL Attenuators for mammo set of six 10500EXL TRIAD Toolkit for Excel 38617 USB to RS 232 Adapter 199XRAY Medical ScopeMet
66. 000 100 and 500 100 CT 3 20m Energy response 5 from 1 mm to 10 mm Al HVL Cable 0 9 m 3 ft Sensitive length 10 cm 4 in chamber inside 6 4 mm 0 25 in 6000 200 and 500 200 CT 10 cm for multislice CT Energy response 5 from 1 mm to 10 mm Al HVL Cable 0 9 m 3 ft Sensitive length 10 cm 4 in Chamber inside 11 44 mm 0 45 in Diagnostic X Ray Quality Assurance Instruments Biomedical Optional accessories 4000EXL 4000 Toolkit for Excel 07 434 Ultra High Purity HVL Attenuators for mammo set of 6 4000 69 Carrying Case 190004 RS 232 Cable 7 6 m 25 ft 9 pin to 9 pin External chamber accessories 6000 528 Radiographic Ion Chamber 6000 529 Mammographic Ion Chamber 6000 529 95 Probe Holder for BRH2 test stand 6000 530B Image Intensifier Ion Chamber 6000 532B Scatter lon Chamber 6000 100 and 500 100 CT Ion Chamber 6000 200 and 500 200 CT High Sensitivity lon Chamber Available ac adapters for specify with order 14 301 110 V ac 9 V dc 500 mA USA and Japan 14 399 230 V ac 9 V dc 500 mA Europe 14 415 230 V ac 9 V dc 500 mA UK 14 415 and 14 416 adapter 230 V ac 9 V dc 500 mA Australia Biomedical Telele gt 4E Key features e Automatically collects measurement results and places them in an Excel worksheet Captures radiation and kV Oca We i hes oe Timi MG waveforms and charts them in an Excel worksheet Templates are p
67. 10cm 2 8 in x 1 2 in x 4 in Weight 0 11 kg 0 25 1b Diagnostic X Ray Quality Assurance Instruments Biomedical Key features The luminance of view boxes for interpretation or QC of mammography images meets or exceeds minimum levels Ambient illuminance levels are below prescribed levels e Viewing conditions have been optimized NIST traceable Performs required ACR NITS measurements Easy to read digital display Small convenient to carry and supplied with its own carry ing case Rugged construction Measure button press it to get continuously updated read ings Releasing the measure button freezes the last reading for convenient reference Range button adjusts the measurement display for the resolution desired LED display visible in very dim light as well as direct sunlight LED displays are inherently robust in compari son to liquid crystal displays LCDs e The battery powered photometer provides tens of thousands of readings Optional accessories 07 634 Fiber Optic Probe Flexible 12 in must be calibrated with meter 07 634 1000 Fiber optic Probe Rigid 1 inch must be calibrated with meter 07 634 1100 Rotating Tlluminance Receptor must be calibrated with meter 89 621 Carrying Case Biomedical O7 661 7662 and 07 644 Need new pic 07 661 662 Collimator Beam Alignment Test Tool 07 644 Grid Alignment Test Tool 07 661 7662 Collimator
68. 1540 m s 6 m s Attenuation coefficient 0 5 dB cm MHz 0 05 dB cm MHz Contrast 90 db with respect to reference Lesions Material Zerdine solid elastic water based polymer Freezing point O C 32 F Melting point above 100 C 212 F Speed of sound 1545 m s 6 m s Attenuation coefficient 0 5 dB cm MHz 0 05 dB cm MHz Contrast 90 db with respect to reference Elasticity Lesion Type I 16 kPa 8 Lesion Type II 25 kPa 8 Lesion Type III 44 kPa 8 Lesion Type IV 56 kPa 8 Diameter Qty 4 10 mm at 15 mm depth one of each hardness Qty 4 20 mm at 30 mm depth one of each hardness Elastograph image courtesy of C Wu at the University of Rochester Ultrasound Quality Assurance FLUKE o Biomedical Key features e Provide users with targets of known hardness e 10 mm and 20 mm diameter spheres e 15 mm and 30 mm depth placements e 4 separate hardnesses e Spheres appear isoechoic on standard B mode imaging 1US Patent 5196343 Ordering information 84 349 Ultrasound Elasticity QA Phantom Multipurpose Tissue Cyst Ultrasound Phantom The 84 317 Multipurpose Tissue Cyst Ultrasound Phantom helps provide both quantitative and qualitative information on the performance of all diagnostic ultrasound imaging systems When used on a regular basis it promotes uniform system performance better patient data and
69. 4 in x 17 in Biomedical 07 600 and 07 678 Key features 07 600 e Reduces exposure to 07 600 Fluoroscopic Beam tHe ees Alignment Device 07 678 w In misaligned fluoroscopic o uy ESTE z _ image intensifier systems the e 10 ms exposure time portion of the field that falls Auto power on outside the visible area of e Auto power off i the image receptor does not e 6 years to 8 years contribute to the useful fluoro JANG Uis scopic image and can result in unnecessary exposure to the Ea patient a If corrective measures are required the 07 600 Fluoroscopic Beam Alignment Device will provide a measurement of optimum beam alignment It consists of an aluminum plate with four sliding brass strips set in recessed channels The strips define the visible area of the image receptor and are adjustable with respect to the center of the measurement plate A transparent plastic overlay on the aluminum plate prevents the vertical displacement of the brass strips Holes drilled at 0 5 inch intervals through the center of each channel are filled with high density plugs The visibility of the plugs in the fluoroscopic image permits their use as a means of centering the device 07 678 DXR Direct X Ray Ruler The 07 678 DXR Direct X Ray Ruler represents the latest in today s technology for alignment of the light and radiation field The 07 678 DXR is extremely easy to use as it is powered on by simply
70. 42 2000 Dimension 55 mm 07 542 1000 For measuring focal spots from 0 3 mm to 0 6 mm Sectors 4 28 patterned sectors with a 1 angle of a single line within a sector Thickness Lead foil thickness 0 03 mm 07 543 2000 Dimension 55 mm 07 543 1000 For measuring focal spots from 0 8 mm to 1 5 mm Sectors 4 35 patterned sections with a 1 5 angle of a single line within a sector Thickness Lead foil thickness 0 03 mm 07 510 2000 Dimension 55 mm 07 510 1000 For measuring focal spots from 1 mm and up Sectors 1 35 360 pattern sector with a 2 angle of a single line within a sector Thickness Lead foil thickness 0 05 mm 07 456 Dimensions Step wedge 2 5 in x 5 5 in x 1 375 in Each step 0 5 in surface 3 mm rise Weight 0 50 kg 1 10 Ib Dimensions Step wedge 3 in x 10 3 in x 1 85 in Each step 12 mm surface 2 1 mm rise Weight 1 45 kg 3 20 1b 07 456 High Purity Aluminum Step Wedges 46 Diagnostic X Ray Quality Assurance Instruments FLUKE o Biomedical 07 456 High Purity Aluminum Step Wedges e Built to US Federal specification GG X 635C e Determines mAs linearity e Determines contrast vs kVp e Used for Darkroom fog testing Film and screen comparison Technique chart development On these high purity aluminum step wedges even numbered steps are identified with lead numerals Ordering information 07 503 2000 High Precision
71. 7 445 57 405 AP PA Filter 57 406 Lateral Cervical Filter 57 407 Lateral Thoracic Filter 57 430 Thin Buildup Filter 57 434 Thick Buildup Filter 57 408 Adult Gonad Shield 57 444 Pediatric Gonad Shield 57 409 Breast Shield Set 57 426 Filter Holder 57 404 57 408 Adult Gonad Shield 57 409 Breast Shield Set 57 426 Filter Holder 57 444 Pediatric Gonad Shield Ordering information 57 429 Chest Filter 57 432 2 inch Wedge Lateral Decubitus at 40 inch FFD 57 433 3 inch Wedge Lateral Decubitus at 40 inch FFD 57 426 Filter Holder set of mounting plates included 57 440 Foot and Ankle Filter 57 441 2 inch Wedge AP Foot at 40 inch FFD 57 414 Wall Rack 57 411 Replacement Mounting Plate 57 405 AP PA 72 inch FFD 57 415 AP PA 40 inch FFD 57 406 Lateral Cervical 72 inch FFD 57 407 Lateral Thoracic 72 inch FFD 57 430 Thin Buildup 57 434 Thick Buildup 57 437 Thin Wedge for conventional machines 57 438 Thick Wedge for conventional machines 57 408 Adult Gonad Shield 57 444 Pediatric Gonan Shield 72 inch FFD 57 402 Basic Full Spine Filter Set 57 445 Deluxe Full Spine Filter Set 57 404 X Ray Protection System oy gi lelel le7yfey diolo ele Quality Control Kit Fluke Biomedical s O7 600QC Quality Control Kit is ideal for performing quality assurance inspections in conventional radiography applications The 07 600QC is best used in con junction with a dosimeter kit enabling the user to measure and veri
72. 70010A Dual Channel Compara tors You can set this level to between O and 100 mR hr with a direct read ing dial setting The 70020 also provides a con venient voltage source to check the actual trip levels of each Dual Channel Comparator Module All comparator modules are forced into the fault indication when the test switch is pressed to quickly check all channels There are two operational modes in the Interrupt mode a fault relay closes whenever any channel goes above the trip level in the Continuous mode the relay is not activated The relay contacts can activate an alarm or stop the drive motor when the system is scanning Biomedical Key features 10970 e Pre wired mainframe e Expandable system e Line operated e Self checking 96010A 50300A e Fully guarded air equivalent chamber e NIST traceable calibration e Electrometer directly connected to ion chamber e Low noise high speed performance 70010A e Bright visual fault indication e Altitude compensation e Direct readout in mR hr e Front panel monitoring and test e Readout of highest channel 70020 ssa e Set mR hr limits oe aid e Two modes interupt ue and continuous Biomedical O07 CRXW and 07 QRX Key features e Calibrates computed radiog raphy CR plate readers and automatic exposure control The wireless 07 CRXW CR AEC TUBE Sane RADCHEX and O7 QRX QA e Assesses ongoing perfor RAD CASSETTE RADCH
73. 905 Manufactured under licensing agreement with Mayo Foundation for Medical Education and Research Optional accessories 07 622 89 622 Carrying Case 07 633 Pinhole Assembly mark measurement scale on the radiographic image Other 0 010 mm applications where object firm distance magnification corrected 07 617 Pinhole Assembly measurement is needed 0 075 mm 07 613 Pinhole Assembly 0 030 mm 0 100 mm 07 623 or et 89 622 Carrying Case Dimensions 12 in x 12 in at base 6 15 in x 6 15 inch at top 07 611 Pinhole Assembly Height Adjustable from 16 94 in to 31 38 in 0 100 mm Weight 5 kg 11 1b 07 623 Dimensions 9 in x 11 50 in at base 4 in x 6 in at top Height Adjustable from 9 in to 18 in Weight 5 kg 11 Ib 07 533 Model 07 533 07 533 1000 07 533 1100 07 533 3600 30 cm long 100 cm long 110 cm long 36 cm long 2 mm divisions 2 mm divisions 2 mm divisions 2 mm divisions Weight 0 04 kg 0 24 kg 0 24 kg 0 04 kg 0 05 1b 0 5 1b 0 5 1b 0 05 1b 50 Diagnostic X Ray Quality Assurance Instruments 07 611 to 07 633 07 620 and 07 635 X Ray Pinhole Assemblies and High Quality Comparators 07 611 to 07 633 X Ray Pinhole Assemblies One of the specifications and chief features of an x ray tube is its focal spot size a very important factor in the resolu tion to be achieved during a radiologic examination A small focal spot size will provide the maximum resolution However ther
74. ACS and telera diology A quick objective and reproducible QC test is needed to ensure optimization of the digitizer and display system As an integral part of your regular QC for a laser scanner or CCD digitizer the digital format PACS Test Pattern will prove itself as an invaluable QC tool for testing image display systems and film printers T The PACS Teleradiology Test Pattern tests e The ability to discriminate between 16 different gray scale levels from its lowest to its highest optical density which is a greater number of gray scale levels than is tested by the SMPTE Test Pattern e For low contrast discrimination with a rose hole type pattern which is not available on the SMPTE Pattern e The ability to discriminate between different gray levels on both sides of the pattern as well as in the center of the pattern These features designed specifically for QC in teleradiology systems provide a more superior test of gray scale reproduction than the SMPTE Pattern e High contrast resolution in horizontal vertical and diagonal axes while the SMPTE Pattern test only horizontal and vertical axes e For specific artifacts which are important to digitization of radio graphs such as the ability to reproduce fine lines blooming from bright areas and light leakage along the sides of the image Specifications Horizontal vertical and diagonal high contrast line Pairs Tests resolution up to 6 lp mm when prin
75. CR RADCHEX and QA RADCHEX ssssessssesessserrssrirerierrrenrrerrserresnne 29 OZ MASS MW AS SiMGLGT a fs tctccidecassressncsssvcand Sasan EE Raiena ara ea EAE anaiai Aaaa ndan aesan 31 660 X Ray and CT Exposure Measurement Instrument nial 06 526 RAD CHECK Plus Dosimeter sses 4 06 526 5240 RAD CHECK MICROKR c essssssesssseessseeseseeseeecseencseeseseeseeseseeucaeenseeeneeeaeeasanenseteneeeeneenes 35 07 494 07 492 07 479 Wide Range Mammographic and Dental kVp Meters u s 36 18 526 Series Service and Quality Control Kits ssssensssossssesussressssrerssseenesrssnses eri 07 453 Digital X Ray Pulse Counter Timer 38 07 487 Dual Range Digital MAS Meter irnn aTa 39 07 469 Wave Precision High Voltage Divider oo ceeeeesceseseeeeeseseeeeteneeaeesseeeeeaseneneeeeeaees 40 18 116 VeriLUM Color Dual Mode Pod Al 07 621 Precision Photometer 0 0 eects i 07 661 7662 Collimator Beam Alignment Test TOO c cccccsssssessecsessessessessessessessecsesseeseeseeseeseeseenss 43 07 644 Grid Alignment Test TOOL sssssc scccccescedhrecaiesazeescecctcsecscasdevescetepssseengazecescersseaeeeranestannaeestanineatee 43 07 591 Focal Spot Test Tool 3 07 501 to 07 555 Test Patterns 07 503 to 07 551 Star Patterns 07 456 High Purity Aluminum Step Wedges ceseeeeseeneseeeeeseeeasseeteeasaseesseeaseneneeeasenenees 46 07 450 PACS Test Patterns in Digital Format Al 07 451 X Ray Output Detector 48 07 608
76. Display Three digit LED legends R min R hr mR hr R mR mSv min mSV h mSv and Sv Battery life Six hours between charges at 20 C with normal usage Automatic shutoff when charge drops below usable level Battery complement One 67 5 V collecting potential shelf life and four rechargeable 1 25 V D batteries for instrument power Battery charge time 10 hours to full recharge at 20 C instrument OFF AC recharge input 117 V 15 50 60 Hz power cord furnished 230 V 15 availableon special order Dimensions WxDxH 14cm x 21 6 cm x 11 4 cm 5 5 in x 8 5 in x 4 5 in Weight 3 2 kg 7 Ib net Ion Chambers Application Diagnostic Beam Measurement Scatter CT Probe volume 4 cm 400 cm 3 2 cm Measurement area 10 cm 100 cm NA Maximum rate Maximum exposure 999 R min 99 9R 99 9 R min 9 99R 9 99 R hr 99 9 mR 999 Recm min 99 9 Recm 99 collection efficiency Resolution on most 10 mR min 1 mR min 0 1 mR hr 0 01 Recm min sensitive range 1 mR 0 1 mR 1 uR 0 001 Recm rate Exposure Intensity limit for 40 R sec 1 8 R sec 10 8 R hr 985 R min a ey ices oe Diagnostic X Ray Quality Assurance Instruments Optional accessories 660 3 Parallel Plate Ion Chamber 4 cm 99 9 R 660 3DE Parallel Plate Ion Cham
77. EX are factory radiation mance of CR plate reader AEC and automatic calibrated NISTtraceable light programmed radiography meters that can be used to APR calibrate balance CR plate e Sets and maintains desired readers also radiation cali clinical system speed dose brated light meters in the field of the CR system The CR plate reader in the field e Calibrates CR plate readers will be calibrated and trace in the field to be traceable to able to the Fluke Biomedical a factory radiation produced ee light condition factory radiation calibrated and Links radiation exposure traceable x ray produced light mR to the front of the plate C exposure accurately and predictably to Both 07 CRXW and 07 QRX have the same x ray energy response as a a CR light measurement value CR system x ray to light conversion efficiency is the same for various CRLU beam conditions This enables them to be used as accurate and precise replace e Provides a reliable and repro ments for the plate reader s light measurement value exposure index value Seen ene ar Most importantly the 07 CRXW and 07 QRX can save valuable time when cali ers specific factory calibra brating or accessing CR readers and AEC used with multiple x ray systems These tion x ray systems may have different filtration and beam characteristics even when e Provides three different located in the same department or imaging center Balancing system performan
78. Kit for Radiographic Film cseeeeeeeseceeeseseeeseeeeeeeeeeeseeeeees 91 Mammography Quality Assurance 18 220 Mammographic Accreditation Phantomsissa 18 250 Digital Stereotactic Breast Biopsy Accreditation Phantom 18 251 2000 Contrast and Resolution Mammography Phantom ceceeceseceeeseseeeseeeeeeeeeeeeeeeeees 18 252 Contrast Detail Phantom for Mammography 18 227 CDMAM PHh Nt M i iii 18 222 Tissue Equivalent Mammography Phantom 18 216 Single Exposure High Contrast Resolution Phantom s sesssessssissrrsssrsrisrrrsnrrernnerrenrnennnes 18 228 Stereotactic Needle Biopsy Tissue Equivalent Training Phantom cccccceeeeeeeees 100 18 229 1313 Mammo Cube Stereotactic Core Biopsy Phantom si 18 229 Triple Modality Biopsy Training Phantom sesssseseersrirerierrssrreerne a 18 230 Series GRID VIEW Breast Biopsy Transport and Imaging System 102 18 203 Mammography Phototimer Consistency Test Tool 18 224 Mammography Phantom Material eee 18 303 Mammography Collimation Assessment Test Tool si 18 210 8000 View Markers for Mammography se ss sesssersssssesrisrrssrirerissrienrienrsnrenninnriennrenienrrennrennt CT Quality Assurance 76 410 4130 AAPM CT Performance Phantom e sessssessrrserrssrerrresrrssreesnisnrerunrnresnrennesrresnersnesnreens 106 76 409 Spiral Helical CT Lesion Detectability Phantom cccccssssseeseeseeseeseees 716 424 4156 Nested CT Dose Phantom Kit for Pe
79. Noise level of imaging protocols This versatile phantom can be used by Research laboratories for e Testing image reconstruction algorithms and interpolation approaches Material Lucite Plate dimensions 10 cm x 10 cm 15 cm x 15cm 20 cm x 20 cm 25 cm x 25 cm Phantom dimensions WxDxH 25 cm x 20 cm x 25cm Weight 8 2 kg 7 18 1b CT Quality Assurance Biomedical Key features e A supplemental phantom to the CT Performance Phantom described in a report by the AAPM task force on CT scanner phantoms Quality of axial and spiral scanning can be assured e Accuracy of clinical diagnosis based on the object s size shape and location will be improved e Users can evaluate scanners objectively and independently of CT manufacturers e No film exposures and no radiation profile measure ments are necessary e All test results can be evalu ated visually by the users in their image displays Scanner evaluation is more realistic what you scan is what you see CT manufacturers to e Evaluate equipment hardware design e Improve imaging software e Facilitate equipment instal lation calibration and preventive maintenance End users to e Set up baseline standards for future reference e Verify scanner performance in the acceptance test e Assist in routine equipment quality control testing e Evaluate vendor supported imaging protocols e Customize image parame
80. Number of targets per group 10 Depth of visualization 1 cm and 19 cm Visualized spacing 20 0 38 mm Material Nylon monofilament 0 10 mm Horizontal plane targets Number of groups 1 Note This target group is also Number of targets per group 10 the Vertical Plane Target Group Depth of visualization 3 cm and 10 cm Visualized spacing 20 0 35 mm Material Nylon monofilament 0 1 mm Axial resolution targets Number of groups 2 Number of targets per group 12 Depths of visualization 2 cm 5 cm 8 cm and 11 cm Axial resolution test range 0 5 mm 1 mm to 5 mm in 1 mm increments Material Nylon monofilament 0 1 mm Lateral resolution targets Number of groups 2 Number of targets per group 6 Depths of visualization 2 cm 5 cm 8 cm and 11 cm Lateral resolution test range 1 mm to 5 mm in 1 mm increments Material Nylon monofilament 0 1 Anechoic targets Number of targets 2 Diameter 8 mm to 2 mm in 2 mm increments Depths of visualization 2 cm 5 cm 8 cm 11 cm 13 cm and 16 cm Phantom dimensions WxDxT 17 cm x 25 5 cm x 7 cm 6 in x 10 in x 2 75 in Weight 5 45 kg 12 lb Ultrasound Quality Assurance Key features e Features three scan surfaces Biomedical e Complies with the AIUM stan dard for quality assurance e Rugged durable e Ideal for service use e Performs a wide variety of tests needed to meet AIUM and ACR ultrasound QC guidelin
81. Screen Film Contact Mesh o seesseseesseessesssessesssessesseesseeseesnesseceacesueeseesuesseeeneeseeeneesneeaeeseeeseesess 48 07 706 Patient Phantom Penetrometer System c sscceesseesseessessesseeeseseseesesseeseesseseseeseeeseesneeseeeess 48 07 894 Computer Monitor Tester s 49 07 622 Multipurpose Focal Spot HVL Test Stand 0 50 07 623 Mammography Focal Spot Measurement Test Stand oo ee eeeeeeeceeeseeeeeseeeaeeeenees 50 07 533 Radiopaque RULELS fs csscscsssiensesucsesseadessenscussstarnscdcaasasoapscasnasseassnsaeeasssesssnasadestssasaeasaeseasitcanariizs 07 611 to 07 633 X Ray Pinhole Assemblies zs 07 620 07 635 High Quality COMparatorS c cecscsssssessessessessessessecseesessesseeseesesseesesseesecseeseeseeseeseeseesss Radiography Fluoroscopy Phantoms and Accessories 57 4 Series CLEAR Pb Compensation Filters oo es eeeeceeseeeeeseeseeeeneneeaseesneneseaseneeeeaeanes 52 07 600QC 07 600QCN Quality Control Kit 2255 07 680 NEMA Cardiology Fluoroscopy Phantom 456 07 649 CDRH Fliieroscopic Phantom sii anda ive nnn ncinieiediananinedi 60 07 601 Fluoroscopic System Resolution Test Tools cesescecssesecesessseseseeeseseeeseaeseaeseeeeeeeseeeeeeeeteeeeees 61 07 800 Series Flex Film Cassettes 00 07 600 Fluoroscopic Beam Alignment Device at 07 6784 DXR Direct X Ray Ruler s sssvesscsceeceseneavetaststee cea enuneedaannniiineianeane 76 710 Digital Subtraction Angiography DSA Phanto
82. Six 5 cc refillable glass vials ey with caps 15 mm x 47 mm h Flood section Diameter 9 in C Depth 1 25 in Star pattern e MTF evaluation Wedge angle 3 e Horizontal and vertical spatial Number of wedges 20 resolution Fan angle 60 e Quadrature setting Wedge length 60 mm e Baseline correction Height 30 mm High resolution hole pattern lmmxlmm 0 75 mm x 0 75 mm 0 5 mm x 0 5 mm Hole depth 9 mm 00000 oo0000 ooooo Concentric conic section Four holes 2 mm x 2 mm Outside diameter 8 in Number of segments 4 Optional accessories 716 903 7000 Copper Sulfate 1 gm l 118 MRI Quality Assurance Biomedical Key features e Complies with AIUM standards e Simulates characteristics The 84 555 for 2D and of the human liver 3D Evaluation Ultrasound e Perfect for QC Service Phantoms consists of two phan not affected by changes toms as described in the AIUM in temperature publication Standard Methods Rugged carrying case for Calibration of 2 Dimensional menier and 3 Dimensional Spatial Measurement Capabilities of Pulse Echo Ultrasound Imaging Systems These phantoms were designed to evaluate measurements taken on ultra 1S Patent 5196343 sound systems using newer spatial encoding algorithms This is especially important for the 3D and 4D ultrasound sys tems currently on the market Both p
83. Star X Ray Test Pattern 07 503 1000 Ultra High Precision Star X Ray Test Pattern 07 509 2000 High Precision Star X Ray Test Pattern 07 509 1000 Ultra High Precision Star X Ray Test Pattern 07 542 2000 Precision Star X Ray Test Pattern 07 542 1000 Ultra High Precision Star X Ray Test Pattern 07 543 2000 High Precision Star X Ray Test Pattern 07 543 1000 Ultra High Precision Star X Ray Patterns 07 550 Ultra High Precision Star X Ray Patterns 07 551 Ultra High Precision Star X Ray Pattern 07 510 2000 High Precision Star X Ray Test Pattern 07 510 1000 Ultra High Precision Star X Ray Test Pattern 07 456 11 Step Wedge Type 2024 Aluminum 07 456 1100 11 Step Wedge Type 1100 Aluminum 07 456 2100 21 Step Wedge Type 2024 Aluminum 07 456 2111 21 Step Wedge Type 1100 Aluminum aE nt SER PACS Test Patterns in Digital Format The 07 450 PACS Teleradiology Test Pattern is superior to the SMPTE Test Pattern for PACS Teleradiology quality control It provides a simple objective approach to system evaluation allowing for quick objective testing of image quality by a single observer Simply digi tize the PACS Test Pattern by loading the test image from the disk and display it at full reso lution on your display monitor Then using your systems controls magnify and view dif ferent areas of the test pattern A regular quality control pro cedure is mandatory to ensure a diagnostic level of image quality with P
84. The American College of making it an extremely useful accessory for training technolo Radiology recommends this gists and physicians as well as for verifying the proper operation type of product in their qual of a mammographic biopsy system ity dseurance Proga Training With the increasing use of breast biopsy procedures it is essen tial that radiology healthcare providers maintain and increase their needle biopsy skills This training phantom is a must for every mammography facility Quality control The breast biopsy procedure depends on several variables for accurate needle placement Thus for patient safety the system must be properly maintained and evaluated A comprehensive mammography quality control program must provide assurances that all aspects of the mammography equipment are operating at optimum levels The Triple Modality Biopsy Training Phantom is the ideal tool for such a program Additionally the phantom can and should be used whenever a new system is installed or repaired to ensure accurate needle placement X ray mammography Research and development This cost effective phantom is also an excellent research and development demonstration tool for manufacturers of mammog raphy equipment Material Zerdine 1 Targets Dense masses 2 mm and 8 mm for core biopsy Cystic masses 3 mm to 10 mm for needle aspiration Volume 500 cc Dimensions WxDxH 10 cm x 12 cm x 9 cm 3 94
85. Yes Lateral full spine 72 in FFD see 57 426 with 57 407 filter E F e Lateral aortic arch 57 407 Lateral Thoracic 2 6 oz 6 5in 1 25in Yes Oblique or AP esophagram 72 inch FFD see 57 426 obese patients E a Lateral chest tomography e Routine lateral thoracic 57 430 Thin Buildup 2 502 6 5in 2 5in Yes E F see 57 426 d 57 434 Thick Buildup 3 50z 6 5in 1 25in Yes E E see 57 426 i 57 437 Thin Wedge 8 oz 6 5 in 4 5 in Yes AP scanograms for for conventional see 57 426 determination of long leg machines length discrepancies 57 438 Thick Wedge 13 oz 6 5 in 4 5 in Yes Full leg radiography for conventional see 57 426 under bodyweight load machines Orthopedic angiographic e Cross table lateral hips 57 408 Adult Gonad Shield 0 5 oz 6 5 in lin Yes see 57 426 a AE 57 444 Pediatric Gonad 0 25 0z 6 5 in lin Yes HE E Shield 72 inch FFD see 57 426 57 402 Basic Full Spine Filter Set Includes CLEAR Pb AP PA Filter 57 405 CLEAR Pb Lateral Cervical Filter 57 406 Lateral Thoracic Filter 57 407 Adult Gonad Shield 57 408 Breast Shield Set 57 409 and Filter Holder 57 426 Weight 1 4 kg 3 1b 57 445 Deluxe Full Spine Filter Set Includes CLEAR Pb AP PA Filter 57 405 CLEAR Pb Lateral Cervical Filter 57 406 Lateral Thoracic Filter 57 407 Thin Buildup Filter 57 430 Thick Buildup Filter 57 434 Adult Gonad Shield 57 408 Pediatric Gonad Shield 57 444 Breast Shield S
86. able ac adapters for specify with order 14 301 110 V ac 9 V de 500 mA USA and Japan 14 399 230 V ac 9 V dc 500 mA Europe 14 415 230 V ac 9 V dc 500 mA UK 14 415 and 14 416 adapter 230 V ac 9 V dc 500 mA Australia a E a8 a6 1 2 1 8 2 4 3 8 Log Rel Exp D Log E curve generated by The Little Genius without external software Specifications O to 4 OD units O to 3 OD 0 02 OD units 3 to 4 OD 1 0 02 OD units 6 AA batteries 1 5 V alkaline 110 V ac with ac power converter Centered at 540 nm 1 mm and 2 mm 8 1 cm x 7 cm x 18 cm 3 2 in x 7 1 in x 2 75 in 1 3 kg 2 8 1b Measuring range Accuracy Repeatability Power requirements Included accessories 07 444 802013 RS 232 Interface Cable 169072 9 Pin Adapter 169071 25 Pin Adapter 07 446 07 444 1CD AutoSTPP X Ray Film Processor QC Software 802013 RS 232 Interface Cable 169072 9 Pin Adapter 169071 25 Pin Adapter Spectral response Aperture size Dimensions WxDxH Weight Ordering information 07 444 The Little Genius Scanning Densitometer 07 446 The Little Genius Scanning Densitometer Film Processor Quality Assurance Handheld Deluxe Digital Clamshell Densitometer Get all the benefits of state of the art features in a compact handheld unit The 07 443 Handheld Deluxe Digital Clamshell Densitometer has today s most wanted features for go anywhere qu
87. ack mount cage designed to accept up to nine 70010A plug in Dual Chan nel Comparator Modules and one 70020 Reference Control Module The Mainframe incudes power supplies 15 V and 6 3 V dc for up to eighteen 50300A Electrometers nine 70010A Dual Channel Comparators and one 70020 Reference Control Module 50300A Electrometers are con nected to the back panel of the Mainframe Power required is 120 V ac or 220 V ac specify at time of order An output connector provides the contacts of the fault relay as well as the output of the highest chan nel in those systems using the Model 7OO10A 96010A 50300A Ion Chamber Elec trometer Module The 96010A Ion Chamber is con structed of air equivalent plastic and is vented The chamber has a window area of 100 cm 5 cm x 20 cm and a volume of 500 cm When used to demonstrate compli ance to the Radiation Control Act seventeen chambers mounted around a semicircle of one meter radius provide 180 coverage with overlap between chambers The 50300A Electrometer may be com bined with a 96010A Ion Chamber to eliminate the problems associated with high impedance cable The rise time is approximately 250 msec 10 to 90 and the output noise is less than 10 mV peak to peak 1 mR hr peak to peak Based on the typical characteristics of the Model 96010A Ion Chamber the electrometer module is factory adjusted to provide a scale factor of one volt for 100 mR hr NIST traceable ion ch
88. ad waveform Retrieves the radiation waveforms from the NERO mAx When this is selected a dialog box opens and the user may select either all of the waveform or a portion of the waveform to be charted If a portion of the waveform is desired the user prompted for start and end times in milliseconds of the waveform window Retrieve kV waveform Retrieves the kV waveform from the NERO mAx When this is selected a dialog box opens and the user may select either all of the waveform or a portion to be charted If a portion of the waveform is desired the user is prompted for start and end times in milliseconds of the waveform window Select com port Allows the user to choose serial communication port COM1 COM4 for 8000 NERO mAx connection Templates Three templates are also provided with the NERO mAx Toolkit for Excel a radiographic template a mammographic template and a fluoroscopic template Each template includes a help worksheet with detailed instructions for its use NERO mAx radiographic Used to perform the following radiographic tests reproducibility template kVp accuracy timer accuracy linearity and beam quality NERO mAx mammographic Used to perform mammography tests required for ACR and template MQSA Measured data from the Model 8000 NERO mAx may be automatically collected in the following worksheets kVp accuracy kVp reproducibility beam quality breast entrance exposure AEC reproducibility average gland
89. agnostic detail of the lungs heart and spine Lateral Decubitus X Ray Compensation Filter Excellent diagnostic detail in double contrast barium enema examinations To obtain the optimum diagnostic detail the AP PA Wedge Filter 57 405 should be used when performing fullspine examinations First the Breast Shields 57 409 are placed on the filter holder The AP PA Wedge Filter 57 405 is placed on top of the Breast Shields The Gonad Shield 57 408 is placed below the AP PA Wedge Filter Buildup filters are used to provide addi tional filtration in the cervical area to compensate for the added exposure that may be needed in the lumbar area Buildup filters are placed on the AP PA Wedge Filter Reference 1 Gray J E Hoffman A D Peterson H A Mayo Clinic Dose Reduction in Radiography for Scoliosis J Bone Joint Surg January 1983 5 12 2 Patient Exposure Reduction During Scoliosis Radiography FDA Publication 85 8251 August 1985 Request Reprint No 361B 3 American Academy of Orthopedic Surgeons Bulletin 32 1 January 1984 4 Downey E F Jr Butler P Less Radiation and Better Images a New Scoliosis Radiography System Milit Med 149 September 1984 526 528 ol M A Rachlin J A Simple Methods to Reduce Patient Exposure During Scoliosis Radiography Radiologic Technology 57 5 1986 6 Petersen T D Rohr W Improved Assessment of Lower Extremity
90. ale RGHHV for BNC 5 Diagnostic X Ray Quality Assurance Instruments 07 622 07 623 and 07 533 07 622 Multipurpose Focal Spot HVL Test Stand The 07 622 Multipurpose Focal Spot HVL Test Stand can be used for half value layer measurements and features extendible legs that provide the enlargement factors required by the NEMA standard It s designed for both over table and under table x ray tube measurements Long leveling screws allow the positioning of a screen film cassette under the base 07 623 Mammography Focal Spot Test Stand It is particularly important to verify the size of the focal spot during acceptance testing of new mammographic equip ment or when a new x ray tube is installed The 07 623 Mammography Focal Spot Measurement Test Stand test stand is designed to make these important procedures easy to perform and ensures accurate results The test stand includes a magnification insert alignment device and fluorescent alignment screen Designed by Joel E Gray Ph D Professor Emeritus Department of Radiology Mayo Clinic Rochester MN 55905 Manufactured under licensing agreement with Mayo Foundation for Medical Education and Research 07 533 Radiopaque Rulers All versions of the radiopaque rulers provide an anatomic land Biomedical 07 533 Designed by Joel E Gray Ph D Professor Emeritus Department of Radiology Mayo Clinic Rochester MN 55
91. ality con trol testing from darkroom to It s easy to use Just lift the shell and insert the test film close the shell and press the READ button The measured optical density appears on the three digit liquid crystal dis play The self contained light source makes it convenient to use anywhere darkroom and from lab to field Specifications Range 0 to 4 0 OD Accuracy 0 02 OD Reproducibility 0 01 OD Temperature range 10 C to 40 C 50 F to 104 F Apertures 1 mm and 2mm Measuring length Throat 135 mm 5 3 in Zero range Auto zeros to density 0 0 Sensor High efficiency silicon photodiode Controls Zero pushbutton zeros unit Power on off switch READ pushbutton initiates READ sequence Calibration control screwdriver adjustable 20 turn potentiometer used to calibrate against a known step tablet Display Three digit 0 5 in LCD with a low battery indicator Light source When turned on during measurement provides extremely long life with minimum spectral and intensity degradation Reduces heating to a minimum Power requirements Four 1 5 V AA batteries approx 3 000 exposures Dimensions WxDxH 8 1 cm x 18 cm x 6 1 cm 3 2 in x 7 1 in x 2 4 in Weight 0 82 kg 1 81 lb Film Processor Quality Assurance FLUKE o Biomedical Key features e Features a self contained light source e Fast and accurate resu
92. aluates e Laser beam alignment Slice thickness spacing and contiguity e Table movement e CT numbers and noise level e CT number uniformity e Relative radiation dose e Video monitor and image processing equipment e Scout and axial scan correspondence e High contrast resolution e Low contrast resolution with optional insert Optional accessories 716 430 1000 Low Contrast Resolution Insert designed for determining the CT unit s abil ity to detect slight differences in contrast Two materials with very similar CT numbers are incorporat ed into the low contrast resolution insert to assess the low contrast detection capability of the unit 716 430 2000 and 76 430 3000 Teflon and Lung Inserts these inserts provide the CT number and density that are important when treatment planning parameters are being established for radiation therapy patients 716 430 4000 Teflon Bone Semi Ring this accessory is used as a beam hardening ring for simulat ing clinical conditions The ring has been machined to slide easily over the phantom so that each of the inserts will have the effect of beam hardening 716 430 1212 Acrylic Insert with Wire 0 5 in 76 430 6000 Acrylic Insert 76 430 7000 Fillable Insert 76 430 8000 Aluminum Insert 89 430 Carrying Case 07 800 5007 Flex Film Cassette 5 in x 7 in 07 800 8010 Flex Film Cassette 8 in x 10 in 07 800 1012 Flex Film Cassette 10 in x 12 in Biomedical
93. amber calibration 70010A Dual Channel Comparator The 70010A Dual Channel Comparator compares outputs of the 96010A 50300A Ion Chamber Electrometer and any desired reference radiation level An input reference voltage of 500 mV 50 mR hr can be set to dem onstrate compliance to the Radiation Diagnostic X Ray Quality Assurance Instruments Control Act If the output of the ion chamber electrometer exceeds this value a bright red light initiates and remains illuminated until manually reset The 70010A Module has an adjust able gain and offset for the output of the 50300A Electrometer Gain is adjusted to compensate for altitude so readings are correct for installations as high as 8000 feet above sea level Normal changes in barometric pres sure can typically be disregarded as they do not exceed 3 To correct reading for normal barometric pres sure changes a correction table is included The 700104 features two inde pendent channels to connect each to a 50300A Electrometer Fifty five feet of cable included connect the electrometers to the back of the 10970 Mainframe The 10970 supplies all required power The 70010A permits the highest output of all electrometers on the system to be read You can use this output as the Y axis on an X Y plot to demonstrate that no output exceeds the 100 mR hr legal level 70020 Reference Control Module The 70020 Reference Control Module sends a calibrated rejection level to the
94. anana receptacles 1 red 1 black Diagnostic X Ray Quality Assurance Instruments 35080M 199XRAY 199XRAY Field applications Bandwidth Dual input 200 100 or 60 MHz Real time sampling rate Up to 2 5 GS s Trigger types Connect and View automatic triggering and a full range of manual trigger modes Extended video triggering Along with its triggering capability for standard interlaced TV signals the instrument also triggers on high resolution non interlaced video systems The ScopeMeter 199XRAY will trigger on all lines nonselective or can select an individual video line from systems with up to 2800 lines per frame Persistence Digital persistence for analyzing complex dynamic waveforms similar to an analog scope Selectable persistence Persistence mode with selectable decay time helps to find anomalies in the wave shape and optimizes the display for color information when working with composite color video Display Fast display update rate for seeing dynamic behavior instantaneously Automatic capture and replay of 100 screens Maximum record length 27 500 points per input record length using ScopeRecord mode Trend analysis TrendPlot paperless chart recorder for trend analysis up to 22 days Independently floating isolated inputs Waveform compare Up to 1 000 V Waveform reference for visual comparisons and automatic pass fail testing of waveforms
95. and documentation systems Fluke Biomedical also provides some of the most trusted and accurate radiation safety medical imaging and oncology quality assurance solutions for regulatory compliance About Fluke Corporation Fluke Biomedical is a divi sion of Fluke Corporation Fluke Corporation is the world leader in the manu facture distribution and service of electronic test tools and software and is a wholly owned subsidiary of Danaher Corporation NYSE DHR B F e alet ji om aat lellare Product Catalog Diagnostic X Ray Quality Assurance Instruments TNT 12000 X Ray Test Device it ccs cctssccicesteirsneiisiecsteceeeesdausiieeeecqentinatiisinuenedcmuintatiieane 3 35080M 199XRAY Non Invasive kVp Divider and Medical Scopemetet s e sscseseeeeeeeees 6 10100AT 10500AT and 10500AMT TRIAD TnT X Ray Field Service Calibration QA Kit 9 10500EXL TRIAD Toolkit for ExC s occccsccccecestsieesiccascssceoecsccatsnteessossaseevastiecstmnueestenssienraeeecicienatncease 15 8000 NERO mAx X Ray Test Device ne 8000mAx NERO MAX Toolkit for Excel oo sees eeeseeseeeeseeseeeeseseseseeseeseeeenesecseenseeenseeeaessaeeseeenseneneeees 21 4000M X Ray Test Device tisini ianiai arateeas eeeta steecdavntisseds a duesesssseneeedds Hieber da saai 23 4000EXL 4000 Toolkit for Excel eee 2d 10970 Crescent X Ray Leakage Detection System teeeeeee aiad 07 CRXW and 07 QRX Wireless
96. ange radiographic filter pack covering 50 kVp to 150 kVp Specialty filter packs may have different characteristics Environmental Temperature range O C to 35 C Relative humidity 20 to 80 Storage temperature 35 C to 50 C Orientation Long axis of the Model 35080M Non invasive kVp Divider oriented perpendicular to axis of x ray tube to eliminate heel effect Power requirements 9 V battery 60 hours operation Dimensions LxWxH 6 cm x 9 cm x 21 cm 2 38 in x 3 5 in x 8 25 in Weight 0 68 kg 1 5 Ib MA190 Accessory Kit The MA190 accessory set enables interconnec tion of the 199XRAY for use in the field A CH of medical imaging and video systems The x Y kit is included with the 199XRAY as a standard accessory The accessory kit includes the following e FlukeView for Windows software e 50 Q BNC feedthrough terminator in insulated enclosure to maintain proper termination of test connections during measurement e 50 Q BNC terminator with 10 1 signal attenua tion to keep test terminal properly loaded while getting optimum signal amplitude to benefit from the instrument s extended offset range 1 Q current shunt for current measurements in insulated enclosure e Safety designed BNC cable 1 5 m 5 ft with plastic connectors for safe connection to test terminals even when not at ground potential e Insulated BNC f to 4 mm banana plug adapter e Dual 4 mm b
97. antoms must These phantoms are recom be used Attenuating mate mended in AAPM Report rial must be used between No 60 seca lanal ear Requirements of Diagnostic the source and AEC or ABC Radiological Physicists detectors Since these detec tors are energy dependent er 5 measurement of skin entrance 76 211 exposure requires the use of patient equivalent phantoms for meaningful results __ p AAPM Report No 31 recom ie mends the use of four unique phantoms for use in diagnostic x rays Fluke Biomedical s Dn 76 2 Series phantoms meet this need These acrylic and aluminum phantoms are patient equivalent and are spe 76 212 cifically designed to conform to the AAPM recommendations 76 213 76 214 Radiography Fluoroscopy Phantoms and Accessories 72 Specifications 76 211 76 2 Series Diagnostic X Ray Phantoms Dimensions WxDxH 4 25 cm x 25 cm x 2 54 cm clear acrylic sheets 1 sheet of 25 cm x 25 cm x 1 mm type 1100 high purity aluminum 1 sheet of 25 cm x 25 cm x 2 mm type 1100 high purity aluminum Weight 76 212 Dimensions WxDxH 8 kg 17 5 lb 5 sheets of 25 cm x 25 cm x 2 54 cm and 1 sheet of 25 cm x 25 cm x 5 08 cm clear acrylic to achieve a 17 78 cm thick phantom Weight 76 213 The Skull Phantom has the same 17 kg 37 1b configuration as the 76 211 but without the air gap Dimensions WxDxH Center sheet 25 cm x
98. as well as allowing rotations about each of these axes The head easily screws onto the stand and locks into place Capabilities and applications e Commission x ray pan oramic x ray CT and cone beam CT systems e Learn how to properly position head for optimal images e Test reconstruction tech niques and algorithms for implant planning and maxillofacial reconstruction e Train and evaluate person nel during implementation of new equipment and techniques e Validate consistency of im age quality Overall size phantom only 22 9 cm x 22 9 cm x 29 2 cm 9 in x 9 in x 11 5 in Phantom weight 5 kg 11 Ib Stand weight 3 2 kg 7 Ib Shipping weight 13 2 kg 29 1b Radiography Fluoroscopy Phantoms and Accessories 07 656 and 07 434 07 656 Cardiac Digital Imaging Cine Video Quality Control Phantom and Patient Identifier This patient equivalent phantom provides permanent patient identification informa tion required by the ACC as well as quality control checks for digital imaging when exposed on the cine film or videotape at the beginning of the study before the patient is placed on the table In addition quality control test of resolution density and contrast and uniformity of focus 07 434 Ultra High Purity HVL Attenutators Because type 1100 aluminum is only 99 0 pure it has some impurities that can give a HVL value that is 7 5 lower than those measured wit
99. aseline correction aspect ratio and single T and T values The 76 903 is constructed of non magnetic materials It is 9 inches in diameter with two inserts and is designed to be filled with an MRI signal producing solution One insert is a series of concentric conic sections The other insert is made up of five sections one for positive contrast two for slice evaluation one for MTF evaluation one for T and T evaluations A void between the sections provides a fully flooded area for signal uniformity Phantom dimensions WxH Star pattern one 120 T1 T2 solution insert one 60 High resolution hole pattern one 60 Flood section one 360 Concentric conic section one 360 OD is 9 in x 4 5 in Weight 3 09 kg 6 82 1b Developed by Seong Ki Mun Ph D Department of Radiology Georgetown University Hospital Washington DC MRI Quality Assurance Biomedical Key features Provides a comprehensive range of tests in one compact unit Slice thickness e MTF evaluation e Spatial resolution e RF signal uniformity e Magnetic field homogeneity Biomedical Individual phantom inserts and sections permit a wide range of tests Folded step ramps rT e Slice thickness Step Interval 1 mm ann e Slice orientation Range 36 mm HE Ly e Interslice gap tll C T and T solution insert
100. atures e Breast phantom to test new generation of mammography machines e A refined quality control for today s advanced imaging systems e Objects within the phantom simulate calcifications fibrous calcifications in ducts and tumor masses Biomedical Biomedical Key features e Perform quality control inspections of mammography system resolution with just The 18 216 Single Exposure one exposure High Contrast Resolution e Meets ACR guidelines Phantom incorporates a 17 5 e Meets MQSA requirements micrometer thick gold nickel e Rugged easy to use and alloy bar pattern This allows cost effective the assessment of resolution e The phantom includes a 30x perpendicular and parallel to peletclals leanne the anode cathode axis in just one exposure This pattern has segments from 5 Ip to 20 Ip mm and is equivalent to 25 micrometers of lead or 2 6 mm of aluminum at 20 keV The bar pattern is permanently embedded in a thin acrylic wafer to protect it from wear and damage The phantom body is available in BR 12 or BR50 50 It enables consistent reproducible positioning of the bar pattern at 4 5 cm above the breast support plate at 1 cm from the chest wall centered laterally as recommended by the American College of Radiology The bar pattern can also be positioned at a variety of heights for more thorough evaluations Material BR12 or BR50 50 Dimensions WxDxH
101. ber 4 cm 99 9 R dose equivalent 660 4 Ion Chamber 4 cc 660 4DE Parallel Plate Ion Chamber 4 cm 99 9 R dose equivalent 660 5 Parallel Plate Ion Chamber 400 cm 660 5DE Parallel Plate Ion Chamber 400 cm dose equivalent 660 6 CT Ion Chamber 3 2 cm Biomedical uses proven technology specifi k ni cally designed to provide you x with the ultimate in versatility and cost effective operation Accurate lightweight por e table this industry standard AAD CHEDE i rl ae dosimeter enables you to gain the critical edge in your QC _ program CE The 06 526 RAD CHECK Plus Battery operation and built in detector virtually eliminate setup time Just place the meter or external ion chamber on x ray table collimate shoot and read the result Precision ion chamber and digital display ensure accuracy plus easy readability Ranges 0 001 R to 2 R 0 01 R min to 20 R min Internal chamber 30 cc volume energy response 5 from 15 keV to 65 keV 30 kVp to 150 kVp filtered 20 5 cm 5 1 cm effective measurement area Center of chamber 1 03 cm below top of chamber Standard calibration At 75 kVp with 4 mm Al filtration at 22 C and one atmosphere Reproducibility Electrometer drift Within 2 short term over 100 mR to 2 R range 1 mGy to 20 mGy 0 5 to 1 mR min typical 6 mR min maximum 5 uGy to 10 Gy 60 pGy min maximum Maximum exposure rate
102. brate and repair the following types of instruments e Area Monitors e Barometers e Blood Pressure Simulators e Defibrillators External Pace Maker Analyzers e Densitometers e Diode Detectors e Dosimeters e Electrical Safety Analyzers e Incubator Analyzers e Ion Chambers e IV Pump Analyzers e kVp Meters e mAs Meters e Electrical Multimeters e Oscilloscopes e Patient Simulators e Pressure Meters Parameter Testers e Radiation Multimeters e Sensitometers e Sp02 Simulators Analyzers e Thermometers e Test Lungs e Ultra Sound Analyzers e Velometers e Ventilators Gas flow Analyzers Filtration Equivalent Potential Equivalent Potential Beam Code kV Beam Code kV Sa L20 20 0 07 DV30 30 2 5 0 98 L100 100 1 98 2 75 DV40 40 2 5 1 44 M30 30 0 50 0 33 DV50 50 2 5 1 81 M50 50 1 00 0 98 DV60 60 2 5 2 13 M60 60 1 50 1 68 DV70 70 2 5 2 45 M80 80 2 6 2 98 DV80 80 2 5 2 78 M100 100 5 0 5 1 DV90 90 2 5 3 1 M150 150 5 0 0 25 10 2 DV100 100 2 5 3 48 M200 200 4 1 1 12 14 9 DV120 120 2 5 4 15 M250 250 5 0 3 2 18 5 DV150 150 2 5 5 36 H50 50 4 0 0 12 4 4 DH40 40 4 2 2 H60 60 4 0 0 6 6 DH50 50 10 3 75 H100 100 4 0 13 5 DH60 60 16 5 35 H150 150 4 0 15 16 8 DH70 70 21 6 77 H200 200 4 0 6 4 0 7 19 5 DH80 80 26 0 8 12 H250 250 4 0 6 1 2 7 2L5 DH90 90 30 0 9 26 DH100 100 34 0 10 15 DH120 120 40 0 11 67 DH150 150 45 0 13 36 Service and
103. c temperature and pressure correction for faster operation in any environment Timesaving scroll functionality Recognizes and ignores spurious background signals e Very low dose rate 20 nGy s at a 1 nGy s resolution e Broader range of dental unit kV and time measurement Biomedical 10100AT 10500AT FLUKE and 10500AMT Biomeaicai TRIAD TnT X Ray Field Service Calibration QA Kit Specifications 10100AT TRIAD TnT Kit Exposure and exposure rate accuracy Basic accuracy of 35050AT 1 of reading 2 range resolution steps over range of 18 C to 28 C and 2 of reading 2 range resolution steps over the full operating temperature range of O C to 50 C Note A 3 NIST traceable calibration is provided with each system and includes effects of 35050AT 96035B and 96020C Exposure time measurement Exposure time accuracy 0 1 of reading 0 2 msec Maximum exposure time 6 5 s 0 2 ms Measurement resolution Measurement modes kVp Dose Time Single shot all in one exposure direct beam measurement of exposure kVp and time autoranging across three decade ranges auto reset between exposures display updates after each exposure Simultaneous measurement of kVp and exposure rate Autoranging across five decades of sensitive ranges automatic drift and offset compensation automatic post exposure display hold Full sensitivity rate Measurement range covers a span from low leve
104. ce tube head filtration choices and dose is an important QA requirement best satisfied with either the 07 CRXW for users who desire a non or 07 QRX filtered beam condition for field plate reader calibration Applications e Software selections of The wireless 07 CRXW is ideal for use by service engineers to initially cali multiple beam conditions for brate and troubleshoot the CR plate reader AEC and density selector settings different CR manufacturers Physicists use O7 CRXW to assess the performance of CR AEC for compliance to e Ideal tools for service engi clinical system speed objectives and patient dose Radiology managers can use neers physicists and quality O7 CRXW to assist in the establishment of technique charts and training to deter assurance personnel mine ALARA techniques for various exam types QA personnel can use 07 CRXW to periodically document the performance of the CR system and to compare CR to film screen systems regarding desired ALARA objectives The 07 CRXW uses Bluetooth to communicate with a laptop computer so that the CRLU CR Light Units EI Exposure Index and estimated mR values measured by the electronic cassette are automatically recorded and displayed on the laptop screen Benefits Using the 07 CRXW to calibrate x ray system AEC and CR plate readers instead of a dosimeter can improve productivity significantly A full system AEC and CR plate reader calibration process can take as much as six hours Employin
105. cessary radiation doses Regular monitoring of x ray systems and timers is an essential part of a good quality assurance program 07 453 Digital X Ray Pulse Counter Timer is a non invasive solid state instrument to mea sure the exposure time of either ac or dc x rays as well as the duration of radiation output produced by a wide variety of medical and dental x ray systems A sensitive x ray detector in the instru ment allows direct measurement of exposure from the x ray head Pulses produced by half wave and full wave x rays are measured as 60 or 120 pulses per second For dc capacitor discharge and three phase x rays 07 453 measures the exposure time in milli seconds When testing x ray timers and controls the time of relay contact closure is measured using the ac input feature An output connector on the side of 07 453 allows the user to view a radiation output waveform on an oscilloscope to diagnose and troubleshoot problems with x ray generators Specifications Accuracy AC input 1 count dc input 2 1 count X ray detection 1 count Sensitivity AC input 90 V ac minimum X ray input 50 kVp 5 mA at 5 cm from top surface of case pointed to target on case Range 9999 pulses 9999 ms Display 0 3 inch liquid crystal Power requirements 9 V battery alkaline or equivalent 48 hours minimum typically six months of normal use AC input jacks 130 V ac maximum 90 V ac minimum input circuit not af
106. cm and the 96035B has a nominal volume of 15 cm Both ion chambers have a fully guarded centrally located collector plate that provides superior collection efficiency The patented 96035B has a dual energy range that enables both diag nostic and mammographic measurements They are accomplished using the other side as the entrance window Patent numbers 4 843 619 4 916 727 and 5 508 526 10100AT 10500AT and 10500AMT 96020C and 96035B Diagnostic Ion Chambers continued Wall material 96020C Composite graphite filled thermoplastic 96035B Graphite coated acrylic methyl methacrylate Window material 96020C 0 76 mm thick graphite coated polycarbonate 96035B Both entrance windows are made of 0 25 mm graphite coated polycarbonate Window density 96020C 91 mg cm 96035B 32 mg cm Active window area 96020C 100 cm centered within the chamber body 96035B Each side of the chamber has a circular active window region centered 7 1 mm further from the BNC connector than the center of the chamber body active window regions have an area of 12 32 cm Collector plate 96020C 0 8 mm thick graphite coated acrylic plate 10 8 cm in diameter 2 16 cm x 2 85 cm guard region electrically isolated from collector area 96035B 0 25 mm thick centrally mounted graphite coated polycarbonate plate 3 18 cm 0 01 cm in diameter 1 27 cm x 0 89 cm guard region is electrica
107. ct small changes in overall system performance The Contrast Detail Phantom for Mammography contains a 7 x 7 matrix of objects The diameter of each row of objects decreases from 0 169 inch to 0 007 inch In each row the subject contrast decreases from approximately 6 6 to 0 41 at mammographic energies The Contrast Detail Phantom for Mammography is easy to use Simply place the phantom on the image receptor surface in the same position as a breast Position the x ray tube and com pression device as in a craniocaudal examination When using the phantom on prone position breast biopsy systems use the rotating top plate of the phantom and the compression device to secure the phantom against the image receptor Choose the appropriate kV and mAs factors 26 kV and 60 mAs works well on most systems or select automatic exposure control Key features Optimized for digital imaging Easy to use compact and lightweight Closely simulates scattering conditions of the breast Rotatable support plate accommodates prone position x ray units The plate can be returned to a position that does not interfere with place ment of the phantom on flat surfaces Geometrically increasing hole depths result in linearly increasing x ray transmission Geometrically increasing hole diameters enable quantitative measurement of the contrast threshold of the mammo graphic system Fg Tis 3 Rotatable support plate accommo Row
108. ctures and 18 228 Stereotactic Needle accurately simulates needle resistance Biopsy Tissue Equivalent Care The phantom should be stored in a cool place and discarded Training Phantom after all lesions have been biopsied 18 229 1313 Mammo Cube Dimensions WxDxH 6 5 cm x 7 cm x 4 5 cm E Core Biopsy Weight 5 oz Individual cube dimensions and weights may vary by 10 sages 100 Mammography Quality Assurance Biomedical Key features e Tissue equivalent under x ray ultrasound and MRI e Compressible Ideal for physician and tech Suspect lesions discovered in x ray Mammography must nologist training and quality often be evaluated under control ultrasound to aid diagnosis e Physical density and attenua and in some cases use of MRI tion characteristics accurately may be indicated The 18 229 Simtleie inei On amare 50 glandular breast BR 12 equivalent Flesh like consistency allows Triple Modality Biopsy Training Phantom is an ideal training device because it can be for the palpation of embed imaged under three modalities ded lesions while accurately and was designed specifically simulating needle resistance found in human tissue Anthropomorphic shape is suitable for compression mammography ultrasound or for needle biopsy The 18 229 Triple Modality Biopsy Training Phantom is a disposable phantom that was MRI examinations designed to closely mimic the properties of the human breast e
109. d luminance response model VeriLUM provides on board gamma correction using BARCO Metheus DOME Image Systems Matrox and RealVision gray scale video boards If the operating system is Microsoft Windows 2000 XP ME or Vista and if the color video card supports downloadable gamma ramps then VeriLUM will use that capability VeriLUM software can be installed on as many workstations as desired no additional licenses are required This allows the VeriLUM luminance pod to be taken from workstation to workstation to perform measurements The VeriLUM luminance pod supports all CRTs and all LCD panels It uses a USB port on the PC thus a simple extension cable provided allows for simple connection Minimum computer Intel PC CD Rom Microsoft Windows 2000 Vista and a video requirements board capable of 1024 x 768 pixels with a minimum of 256 colors or a grayscale video board Calibration Traceable to a NIST source Luminance accuracy t 2 Luminance repeatability EL Luminance range 0 05 cd sqm to 1000 cd sqm Weight 0 45 kg 1 Ib Diagnostic X Ray Quality Assurance Instruments Photometers are required for medical scientific and labora tory applications The 07 621 Precision Photometer utilizes a filtered sensor with spectral response tightly calibrated to the CIE photopic response The illuminance receptors closely follow the Cosine Law relative sensitivity versus angle of i
110. diatric Adult Head and Body 176 419 4150 CT Dose Phantom Kit for Pediatric Adult Head and Body lt 76 414 4150 CT Dose Phantom Kit for Adult Head and Body 109 CT Ion Chambers i isiisecccicscsccsseessesstessscccevscscescestversstisisastctsrevesserses 110 76 430 Mini CT QC Phantom eel Il 76 432 CT Spiral PRantom 0 c ccceeeseeessseeeeceeeeeseeeeeeeeeeeseeeeeaeeaeeees 112 84 357 Interventional Triple Modality 3D Abdominal Phantom 0 cece 113 MRI Quality Assurance 76 907 MR Uniformity Linearity Phantom AAPM c cccscsssssssssesssssesesseesssseesesseesssseesesseeseeseesesees 114 76 908 MR 3D Slice Thickness High Contrast Resolution Phantom AAPM 114 76 904 MRI Surface Coil Phantom eeeeseeeesesesseseessesseeasseseseeaeeeeeeeeseaeee wll5 262903 MRI Multipurpose Phantom sccccscscasssassscssascarseddescasacscssaroadscscsnsissessasseessnzandnsnssticsssasassabsaresesects 117 Ultrasound Quality Assurance 84 555 Ultrasound Phantoms Set for 2D and 3D Evaluation ou eeeeeeeseeeeeeeeeteneeeeeenes 119 84 347 Gray Scale Ultrasound Phantom 121 84 349 Ultrasound Elasticity QA Phantom 122 84 317 Multipurpose Tissue Cyst Ultrasound Phantom 123 84 340 General Purpose Multi Tissue Ultrasound Phantom 124 84 342 General Purpose Urethane Ultrasound Phantom eeeeeeseeeseeeeeeeeneeeeeeanenes 125 Service and Calibration PX 0 79 oy INIO ee ep eR Pe Te AP Tee ee 126 Galibrat
111. dis tance to yield free air entrance skin exposure ESE fluoroscopic exposure rate or average glandular dose for mammography The output can be selected in units of R or air kerma 78 Radiography Fluoroscopy Phantoms and Accessories Contrast Test Disks intensifier tube lens system me Measuring the percent con e For quality control testing of trast using the Fluoro Contrast the cine imaging chain Test Disks can be performed e Testing can easily be agi annually and or whenever a performed by the in house e installed This test should be 07 614 8080 part of the QC testing program e Help measure fluoro input Sa of the cine imaging chain uelhe Mae Le i Fluoro Contrast Test Disks e Simulates average adult k make performing all required patient measurements easy The disks satisfy NEMA National 07 638 n Electrical Manufacturers Ne a a disk is taped to the center of r the fluoro grid during a 2 to _ Adult Cine Attenuator in the 07 614 8080 07 638 Disk thickness Dimensions 07 638 and 07 614 8080 oy Bley E 10X10 Biomedical Key features 07 638 e Designed specifically for monitoring the percent contrast of the image 07 638 Fluoro new image intensifier tube is fo Ni Association requirements for image intensifiers and facili tate compliance with NEMA Standard XR 16 To measure percent contrast 3 second cine run using the beam Th
112. e R min and mR pulse mAs pulse and kV Peak AMSE mode AMSE mode is used for Automated Measurement of Sequential Exposures This mode is used to measure the output of CINE generators In AMSE mode the NERO mAx measures kVp Avg Exposure rate mR frame kV Eff mAs frame kV Peak and Time frame ms frame CT exposure mode CT Exposure mode is used to make CT exposure measurements using the 6000 100 CT ion chamber The CT probe must be connected to the NERO mAx detector s external ion chamber input in this mode Exposure mode HVL mode Exposure mode is used to make exposure and rate measurements using the NERO mAx s internal ion chamber or an external ion chamber In the HVL mode the NERO mAx calculates half value layer based upon a series of exposure or rate measurements made with varying thicknesses of aluminum absorbers placed in the x ray beam A minimum of two exposures are required and up to ten exposures may be used Calibrate mode Calibrate mode is used to enter and store calibration factors for ion chambers used with the NERO mAx Setup mode Setup mode is used to set the instrument s parameters such as the real time clock temperature and pressure Unit ID Displays the NERO mAx s serial number firmware part number and level Optional external chamber accessories 6000 528 30 cm3 Energy response within 7 from 30 kVp to 150 kVp 15 keV
113. e on CD two meter RS 232 inter face cable and adapters 37581 Test Stand 37581 ion chamber stem HVL filter tray 37688 HVL filter set 37668 35050ATCD User service manual 37500D Kit Carrying Case 10500AT Components in 10100AT Kit plus 35080M Non Invasive kVp Divider 37617 Wide range Filter Pack 50 kVp to 150 kVp 10500AMT Components in 10500AT Kit plus 35035 mA mAs Meter A 23 Universal Test Lead Kit Ordering information 10100AT TRIAD TnT Dosimeter Kit 10500AT TRIAD TnT X Ray Field Kit Service Calibration QA Kit 10500AMT TRIAD TnT X Ray Field Kit Service Calibration QA Kit Biomedical Key features e Automatically collects measurement results and places them in an fem SS a Excel worksheet ee pE e ees ee a ee ee Ml are ioe oe it EHE grm uee SSH ee 2 4 3 Automatically captures kV Poe eee Fes fy ier een we f waveforms and charts them CE o o neiet Ci m aea a iana ines ai ieee Mias DOi ARAE attend B in an Excel worksheet e Templates are provided 7 a for QA tests on radiographic f fluoroscopic and mammo i ara graphic x ray machines Pl e Templates may be modified to perform user specific tests and generate customized reports e Allows complete remote control of the TRIAD Automatically downloads Model 35050A and 35050AT Dosimeter configuration settings Compatible with Windows 2000 and above and Microsoft Excel 97 2000 ig Eee F TILili tel t
114. e are other factors in the construction of an x ray tube such as the heat dissipation within the target which limits the minimum size of the target In order to determine the focal spot size of an x ray tube a small and precise pinhole is often used Its size must be very small compared to the focal spot to be measured Any of four precision pinholes can be used with our 07 623 and 07 622 test stands The test stand height is adjust able in order to maintain the minimum magnification factor of two A fluoroscopic screen is part of the test stand and is used for centering the focal spot before exposing the film The 0 010 mm pinhole diameter is for focal spot sizes from 0 5 mm to 0 10 mm the 0 030 mm pinhole diameter is for focal spot sizes below 1 0 mm the 0 075 mm diameter is for focal spots from 1 0 mm to 2 5 mm the 0 1000 mm diameter is for sizes above 2 5 mm The pinhole diaphragm is made from a 90 10 gold platinum alloy in accordance with the table and figure 07 620 and 07 635 High Quality Comparators Magnification 25X Supplied with a O to 5 mm reticle Features a knurled ring that adjusts the focal point to personal preference Transparent body allows illumination to fall on magnified area Supplied with protective storage case An excellent high quality precision magnifier Magnification 7X Supplied with its own leather case Fits in the palm of your hand Transparent body allows illumination to fall on magnified area Accu
115. e density This uniform density among all Fluke Biomedical phantoms provides the user with a standard for comparing the performance of different scanners CT Quality Assurance Biomedical Key features e Meets guidelines in AAPM Report No 1 for Performance Evaluation and QC of CT Scanners e Single system measures nine performance parameters This ONE phantom evaluates e Noise e Spatial resolution e Sensitivity low contrast resolution e Absorbed dose e Size dependence e Contrast scale e Slice thickness e Alignment e Linearity e Beamwidth FLUKE o Biomedical 776 410 4130 AAPM CT Performance Phantom Specifications Resolution insert Dimensions ODxL 7 5 in x 2 5 in with 6 inch diameter solid acrylic block 76 410 4130 Block has eight sets of five holes 1 75 mm 1 5 mm 1 25 mm 1 00 mm 0 75 mm 0 61 mm 0 5 mm and 0 4 mm round 76 410 4132 Block has nine sets of five holes 1 75 mm 1 5 mm 1 25 mm 1 00 mm 0 75 mm 0 61 mm 0 5 mm 0 4 mm and 0 2 mm round In both phantom inserts the holes are spaced longitudinally on mm centers and vertically on centers equal to twice the hole width All cavities are filled with air The 6 inch block is sectored 1 25 inch out on radius The insert contains 0 014 inch stainless steel wire positioned longitudinally to the insert plates The wire allows simple computation of linespread functions A sectored 1 25 inch portion of th
116. e main 6 inch block permits an edge gradient to be measured Beam width insert Dimensions ODxL 7 5 in x 3 5 in Contains three 0 020 in x 1 00 in aluminum strips angled at 45 positioned on the center line and displayed vertically A simple direct calculation permits the accurate measurement of beam width Adjacency is determined merely by a double exposure of two adjacent frames Low contrast extension Dimensions ODxL 8 5 in x 2 75 in solid acrylic block Has two each of the following 2 25 inch deep cavities 1 in 0 75 in 0 5 in 0 375 in 0 25 in and 0 125 in diameter spaced twice the appropriate diameter apart one row of cavities on each side of the center line Cavities with screw locking sealing ports are easily filled with dextrose or sodium chloride solutions of various densities The user may adjust densities to any value suitable for the scanner Typically 2 or 3 differentials in density between cavities are used Alignment pin Dimensions ODxL 0 25 in x 3 in aluminum with tapped hole allowing pin to be secured to cover plate TLD insert Dimensions ODxL 0 5 in x 3 5 in polystyrene rod drilled 3 inch deep to accept TLD inserts Resealable cavity Tapped on other end to allow mounting to cover plate External whole body resolution and noise ring 76 411 Annulus 12 in OD x 8 5 in ID x 2 5 in long contains the same hole pattern as the Resolution Insert at two locations 90 apart Permits whole
117. e plug e Diagnostic viewing center over six panels surface and recess mounted TECHLINE provides maximum quality and flexibility for radiological film interpretation TECHLINE is a high end line that boasts the EvenVue Reflector System for uniform lighting Cluster Switching for optimal convenience and many other standard features Applications TECHLINE is ideal for use in hospital and medical high volume environments It incorporates the most com monly requested features and benefits desired by diagnostic imaging professionals Two over two panel recess mounted unit 77 222TR Body construction 18 gauge welded steel construction 3 375 inch deep body Ballasts Safety rating All ballasts are UL listed and C S A approved rapid start low leakage thermally protected Class P type These ballasts have self starting reliability exceeding 10 000 cycles with an anticipated 50 000 hours of operating life Line cord and plug Each surface mounted fixture comes standard with a grounded chassis 7 inch line cord and NEMA 5 15P 2 pole 3 wire ground Film grip Roller gravity film holding system accommodates all film thickness variations This grip will not scratch or tear film Requires no field adjustments Open sides facilitate viewing of oversize film Continuous bottom film ledge Allows for the placement of small film formats on the top and bottom of viewing area Finish Powder coa
118. e resulting optical densities to the side and behind the image of the disk on the developed cine frames are then measured with a calibrated densitometer such as our Hand Held Deluxe Digital Clamshell Densitometer 07 443 07 614 8080 Adult Cine Attenuator The input radiation level of a fluoroscopic unit can be measured directly by placing an x ray ion chamber behind the antiscatter grid and then imaging the appropriate cine attenuator The adult model has a 2 4 mm copper plate sandwiched between 0 125 in thick acrylic sheets The attenuator is designed to simulate an average adult patient in regard to the exposure factors required by the ABC system The final optical density on the processed frames is controlled by the size of the aperture in the diaphragm which is located directly in front of the cine camera lens To determine the optimal on frame optical density a series of cine runs are made using different sized apertures in the beam Optional accessories 07 638 07 443 Handheld Deluxe Digital Clamshell Densitometer 0 125 inch thick lead sandwiched between two 0 125 inch thick white acrylic plates 17 8 cm x 17 8 cm 7 in x 7 in Weight 1 42 kg 3 15 1b Radiography Fluoroscopy Phantoms and Accessories The Little Genius Scanning Densitometer The 07 444 Little Genius Scanning Densitometer stands head and shoulders above all FLUKE o Biomedical Key features e B
119. e you to evaluate adjust aperture concen and optimize fluoro video cam eras brightness systems and image processing systems Its proven design makes it ideal for use by x ray service engineers Substrate uniformdensity plate Dual grey scale steps to set video level gamma peak whites Lead disks to set black level f Largecirdes X ray image White dots tosetsweep to check resolution linearity preamp frequency characteristics aperture correction Two 2 absorber plates not shown tocheck operation of automatic brightness system Phantom diagram Outside diameter 22 78 cm 8 97 in Thickness 1 28 cm 0 5 in Weight 1 86 kg 4 1 1b Radiography Fluoroscopy Phantoms and Accessories Biomedical 76 2 Series Key features e Phantoms conform to AAPM recommendations contained in Report No 31 Standard JCAHO requires that x ray ized Methods for Measuring exposure measurements be Diagnostic X Ray Exposure determined for commonly used Patient equivalent acrylic and projections in all radiographic un MAN Poemon ayer ele ites In order t id the necessary attenuation sul eS OP 2 O provi c between the source and AEC T this information when using or ABC detectors automatic exposure control Helps you comply with JCAHO AEC or automatic brightness requirements for radiographic control ABC systems spe exposure measurements cially designed ph
120. each body part This is controlled by computers rather than chemical processors and soft copy displays which are calibrated using light meters rather than visual inspection CR DR systems also incorporate laser beams photomultiplier tubes network gateways and laser printers The 07 605 7777 is designed specifically for evaluating the entire CR DR image acquisition chain Ideal for use as a preventive maintenance quality control test tool the O7 605 7777 can also be used to take regularly sched uled measured data points from the image such as line pair resolution measurements ROIs regions of interest and geometry symmetry Measurements angle can be used to evaluate monitor as well as printed film image quality By performing daily quality control checks both before the first patient is examined and at the end of the day equipment problems can be accurately and easily pinpointed and corrected Equipment downtime is significantly reduced resulting in increased patient throughput Patients no longer need to endure repeat exams due to poor image quality You ll soon realize a dramatic savings in film costs when you use the 07 605 7777 as part of your QC program In addition radiological personnel will experience significantly less of the problems and frustrations associated with equipment mainte nance and thank you for it 35 5 cm x 43 1 cm x 1 5 cm 14in x 17 in x 0 5 in 3 2 kg 7 05 1b Dimensions WxDxH Weight
121. ector MDCT units e Meets requirements of FDA performance standards e All new carrying case with wheels and pull handle e Case includes space for CT Ion Chambers purchased separately 176 424 4156 Kit Adult body phan tom adult head phantom pediatric head phantom and acrylic rods around the perimeter 90 apart and 1 cm from the edge and the pediatric head center insert has one probe hole in its center The inside diameter of the holes is 1 31 cm Each part includes five acrylic rods for plugging all the holes in the phantom A sturdy storage and carrying case with wheels and pull handle that holds all three phantoms is included An optional smaller case without wheels is available Optional accessories 89 419 Carrying Case with wheels and pull handle for 716 419 4150 The CT Dose Phantoms were designed in accordance with 89 414 Carrying Case for the Food and Drug Administration s performance standard for 76 414 4150 diagnostic x ray systems which includes regulations specifically applicable to CT systems 21 CFR 1020 33 Ordering information 76 424 4156 Nested CT Dose Phantom Kit for Pediatric Adult Head and Body including carrying case with wheels and pull handle Specifications 716 424 4156 Adult body phantom Dimensions Lx 15 5 cm x 32 cm Weight 11 3 kg 25 1b Adult head pediatric body phantom Dimensions Lx 15 5 cm x 16 cm Weight 2 3 kg 5 lb Pediatric head
122. ed to evaluate conventional mammographic x ray equipment film and cassettes However with the increase of digital imaging in mammography especially when performing stereotactic breast needle biopsies and preoperative needle localizations the phantom can aid in achieving improved image quality processing display quality and speed in these new modalities What makes the CDMAM Phantom so special The CDMAM Phantom consists of an aluminum base with gold discs 99 99 pure gold of varying thicknesses and diameters which is attached to a Plexiglas cover The 5 mm thick Plexiglas cover PMMA plate has a 2 mm deep cavity that accommodates the aluminum base with gold discs The assembly PMMA and aluminum has a Plexiglas equivalent thickness of 10 mm under standard mammography exposure conditions The aluminum base is 0 05 mm thick Al 1050 99 5 pure aluminum The base has been polished and anodized black Precisely measured gold discs of varying thickness range 0 05 um to 1 6 pm and diameter range 0 1 um to 3 2 pm have been attached to the base by means of evaporization Finally the base has been airbrushed to protect the gold discs The Gold Standard of Mammographic Phantoms The discs are arranged in 16 rows and 16 columns Within a row the disc diameter is constant with logarithmically increasing diameter The precision of the disc diameter and thickness makes the CDMAM Phantom an ideal tool for conducting contrast
123. el Bjomedical Diagnostic Imaging Product Catalog 2009 2010 TNT 12000 X Ray Test Device 35080M 199XRAY kVp Divider and Medical ScopeMeter 07 QRX Wireless QA RADCHEX CR QC Productivity Device Fluke Biomedical 76 424 4156 Nested CT A Dose Phantom Kit for Better products More choices One company Pediatric Adult Head and Body Radiation Oncology Product Catalog Providing solutions not just products Today biomeds physicists RSO s other medical personnel must meet increasing regulatory pressures higher quality standards and rapid technological growth while performing their work faster and more efficiently than ever Fluke Biomedical provides a diverse range of software and hardware tools to meet today s challenges Service Fluke Biomedical is dedicated to providing the best service within the healthcare industry Equipped with the best credentialed facilities onsite experts and full asset management capabilities Fluke Biomedical s service team is always on call to take care of its customers Fluke Biomedical s world class staff leads the industry in post and pre sale support including help ing customers choose the best products and accessories for their needs technical support product calibration and repairs Regulatory compliance Fluke Biomedical s benchmark quality operates to the most rig orous standards in the industry including compliance with ISO 9001 2000 ISO 13485 2003
124. els were measured under the following conditions an ambient temperature of 21 C 70 F 118 V line voltage and new lamps Light levels measured in the field may vary with the local environment including lamp age line voltage ambient temperature and lamp temperature These measurements are subject to change without notice Surface mounted Dimensions inches 200 series 2 lamp 300 series 3 lamp 400 series 4 lamp Viewing Length Height Model Shipping Model Shipping Model Shipping area wot 1b wot 1b wot 1b 1 panel 14 in x 17 in 14x17 71 201TS 24 71 301TS 24 71 401TS 24 2 panel side by side 28 x 17 71 202TS 44 71 302TS 44 77 402TS 44 3 panel side by side 42x17 77 203TS 64 71 303TS 64 71 403TS 64 4 panel side by side 56 x 17 71 204TS 64 71 304TS 64 77 404TS 64 5 panel side by side 70x 17 71 205TS 71 305TS 107 77 405TS 107 6 panel side by side 84 x 17 71 206TS 125 71 306TS 125 71 406TS 125 1 over 1 14in x 17 in 2x 14x17 77 211TS 37 77 311TS 37 77 411TS 37 2 over 2 2x 28x17 71 222TS 82 71 322TS 82 71 422TS 82 3 over 3 2x42x 17 71 233TS 125 71 333TS 125 71 433TS 125 4 over 4 2x 56x17 71 244TS 71 344TS 71 444TS 2x 70x 17 71 255TS 307 crated 77 3551 307 crated 77 455TS 307 crated 6 over 6 2x 84x17 71 266TS 346 71 3661 346 71 466TS 346 crated crated crated Viewing hei
125. ent backlight Detectors Ion chamber and solid state kV detectors Ion chamber volume 45 cc nominal Window area density 38 mg cm Polycarbonate HVL set 2 30 mm 1 0 mm 0 3 mm Al Power requirements 12 V de 1 A external supply Rechargeable internal batteries supply more than 4 hours of continuous service with overnight charge Size Volume 0 065 m 3960 in Console 22 86 x 23 17 x 8 26 cm 9 00 x 9 12 x 3 25 in Detector 16 66 x 9 4 x 6 55 cm 6 56 x 3 70 x 2 58 in Filter cards 6 1 x 15 88 x 0 8 cm 2 4 x 6 25 x 0 31 in Weight Shipping 10 43 kg 23 1b Console 2 067 kg 4 56 Ib Detector with card 0 747 kg 1 65 1b Filter cards 0 090 kg and 0 094 kg 2 9 oz and 3 2 oz Diagnostic X Ray Quality Assurance Instruments FLUKE o Biomedical Optional accessories 07 434 Ultra High Purity HVL Attenuators for mammo set of 6 External chamber accessories 6000 528 Radiographic Ion Chamber 6000 529 Mammographic Ion Chamber 6000 529 95 Probe Holder for BRH2 Test Stand 6000 530B Image Intensifier Ion Chamber 6000 532B Scatter Ion Chamber 6000 100 and 500 100 CT Ion Chamber 6000 200 and 500 200 CT High Sensitivity lon Chamber Available ac adapters for specify with order 14 328 110 V ac 12 V dc 1000 mA USA and Japan 14 401 230 V ac 12 V dc 1000 mA Europe 14 414 230 V ac 12 V dc 1000 mA UK 14 414 and14 416 adapter 230 V ac 12 V dc 1000 mA Australia
126. ent modes and three system control modes are available and clearly displayed on the control console screen for easy access and selection Applications The NERO mAx consists of the control console detector detector cable two filter cards mAs leads Excel Add in ac adapter HVL plates instruction manual and carrying case The compact control console houses the rechargeable battery super bright easy to read backlit display eight control buttons and the sophisticated electronics necessary for accurate repro ducible measurements Connectors for power input RS 232 printer scope output and the NERO mAx detector are located on the control console s rear panel The NERO mAx detector contains sensors for simultaneously measuring kV exposure or rate and mA or mAs Solid state detectors are used to measure kV An ion chamber located in the top of the detector is used for exposure rate measurements Connectors for external ion chambers and the NERO mAx detector interface are located on the rear panel of the detector The front panel has a keyed opening for the NERO mAx filter cards and a connector for mAs leads The filter cards contain the various filters needed to accurately measure kilovoltage Each filter card is coded so that the NERO mAx knows which filter is in use and its position The NERO mAx also verifies that the filter card is valid for the selected measurement mode The two filter cards are keyed so they may only
127. er with kVp Capabilities includes the MA190 Medical ScopeMeter accessory kit 10500AT and 10500AMT Kits 37355 37351 Mammographic Filter Pack Pair includes Cadmium k edge mammo filter pack 27 5 kVp to 29 5 kVp 0 5 kV accuracy linear mammo filter pack 22 kVp to 40 kVp 1 0 kV accuracy Note Mammo filter packs are designed for molybdenum anode beryllium window generators Diagnostic X Ray Quality Assurance Instruments r lelae it elayA W Gis 35035 Digital mA mAs Meter The 35035 Digital mA mAs Meter is a versatile instrument for x ray service engineers field service engineers and biomed ical engineers to measure mAs and fluoroscopic mA accurately for diagnostic radiographic and fluoroscopic imaging equipment The 35035 Digital mA mAs Meter operates with an easily replaceable 9 volt alkaline battery for extra convenience and portability 37946 Mobile Filter Pack 50 kVp to 135 kVp 2 accuracy 33551 CT Filter Pack 70 kVp to 140 kVp 2 accuracy kVp 2 accuracy 38237 Low Range Filter Pack 30 kVp to 90 kVp 2 accuracy Available ac adapters 9 V 200 mA specify with order 14 106 USA and Japan 14 107 Europe 14 108 UK 14 109 Australia FLUKE o Biomedical Included accessories 10100AT 35050AT Dosimeter 96035B 15 cm Ion Chamber 96020C 150 cm Ion Chamber 38208 Coax triaxial Cable 6 m 20 ft 37594 Programming Kit 37594 includes customization softwar
128. es e Includes an in house certification traceable to NIST standards YERTICAL axial t PLANE RESOLUTION axia e RESOLUTION STEPPED MASS em LaTeRaL RESOLUTION T LATERAL O 1 RESOLUTION steppen mass Emm 2mm oe 7 1 ot STEP MASS PATTERN L _ d Diagram showing internal targets b a Service and Calibration Fluke Biomedical s Global Calibration Lab is NVLAP Lab Code 200566 0 accredited adheres to ISO 17025 2005 ANSI Z540 Mammography MQSA and CNSC and is traceable to national and international stan dards Fluke Biomedical offers one stop bulk contracts for managing larger instrument pools including various asset management alternatives for pools larger than 150 units Fluke Biomedical s asset management program takes over your grueling task of instrument tracking and allows you to use your time more productively If you have a large number of instruments that require service you can greatly benefit from this quality service Proper protocols are strictly followed eliminating the problems with inspectors and audits that can result when other less qualified labs perform the calibrations Instrumentation includes Fluke Biomedical as well as other industry models Tungsten Anode NIST Traceable Techniques PTB Traceable Techinques Biomedical Fluke Biomedical s Global Calibration Laboratory is equipped to cali
129. es to deliver maximum output c One 7 in x 7 in x 0 03125 in aluminum penetrometer plate with 0 25 in 0 176 in 0 125 in 0 088 in and 0 0625 in holes Place this plate between the two aluminum blocks and ascertain the contrast gradient of the pen etrometer on image amplified systems d Two sets of legs one 1 25 in long and one 10 375 in long Ordering information 07 451 X Ray Output Detector includes BNC Output Connector 07 706 Patient Phantom Penetrometer System 07 608 Screen Film Contact Mesh Biomedical Key features e Fully featured bench top design e Up to one hundred scan The 07 894 is an easy to formats are available use portable instrument for e Allows for quick easy testing repairing and aligning troubleshooting testing analog computer monitors LCD and alignment of computer monitors displays and video projection systems A microprocessor and rogrammable logic based p g g e Four video output connections design provide significant per for direct connection to PC formance improvement over SUN MAC and BNC monitors the common memory based Features convenient VGA Push button operation includ ing last setting memory monitor testers The 07 894 MAC and SUN groupings of Computer Monitor Tester pro commonly used scan formats ri vides up to one hundred scan e Selectable sync outputs for formats including all current oe F Tent aor Video Electro
130. et 57 409 and Filter Holder 57 426 Weight 1 4 kg 3 1b 57 404 X Ray Protection System Includes Adult Gonad Shield 57 408 Breast Shield Set 57 409 Filter Holder 57 426 and Pediatric Gonad Shield 57 444 These models manufactured under licensing agreement with the Mayo Clinic Mayo Foundation These models manufactured under licensing agreement with Alvarado Orthopedic Research Company Radiography Fluoroscopy Phantoms and Accessories E Lead Steel Sandwich E Magnetic Tape Plastic Lead Plastic 57 4 Series CLEAR Pb Compensation Filters Breast Shields 57 409 Thick Buildup Filter 57 434 same as 57 430 filter above but for patients whose measurements exceed 25 cm Z Thin Build Up Filter 57 430 Chest X Ray Compensation Filter For greater diagnostic detail over entire lung with fewer AP PAFilter Tepeats Reveals details that 57 405 conventional x rays usually miss The CLEAR Pb Chest X Ray Filter eliminates a problem commonly encountered in chest x rays a portion of the lung field is usually severely under exposed because it is hidden behind the hilum With the CLEAR Pb filter you can increase the beam intensity sufficiently so that all details of the lung and the posterior mediastinal field are clearly revealed The CLEAR Pb filter attenuates the x ray beam while protecting the rest of the field from overexposure You get clear di
131. extended top edge to aid the user in positioning it on recum bent biopsy tables On digital mammography units this phantom can test the high contrast spatial reso lution of the system with the results being viewed on the monitor The focal spot high contrast resolution can also be determined by placing a conventional mammography cassette behind the phantom and making an appropriate exposure It is suggested that a reso lution test pattern from 5 20 LP mm be used to evaluate the condition of the focal spot Instead of making focal spot mea surements that can be ambiguous an accurate determination of the x ray tube s resolution ability can be measured by using the optional Resolution Test Pattern 07 555 On conventional mammography units the phantom can be used to meet the ACR guidelines for testing focal spot resolution The ACR suggests placing a resolution target 4 5 cm above the image receptor and imaging twice once parallel to the anode cathode axis and once rotated 90 degrees With two resolution targets this can be achieved in a single exposure The grey scale step wedge can also be used to check the dynamic range of the entire system indicate processing problems and variation in film emulsion Phantom body Materials Cast acrylic block with aluminum plate Dimensions WxDxT 6 66 cm x 6 4 cm x 4 3 cm 2 6 in x 2 5 in x 1 7 in Weight without test patterns 8 oz 0 5 Ib 07 555 Optional Resolution Test Pattern
132. fected by reversed polarity Output signal BNC connector for waveform analysis Connections None required for direct exposure measurement Controls indicators Dimensions LxWxH Three position switch Pulse Off Milliseconds Four digit LCD 0 4 in character Low battery indicator Low Batt appears in display when battery voltage reaches 5 3V 0 3V Power on LED green oscilloscope output 14 7 cm x 8 cm x 4 cm 5 8 in x 3 15 in x 1 6 in Weight 0 21 kg 0 5 Ib Diagnostic X Ray Quality Assurance Instruments FLUKE o Biomedical Key features e Measures duration of radiation output produced by x ray generators e Measures ac or dc x rays Gives direct readings time or pulses e Can be used for medical or dental x ray systems Designed specifically to allow service personnel to accu rately and easily assess the performance of x ray genera tors timers and controls e Saves time and money by reducing repeat examinations e Easy to read digital display e Automatic reset holds a read ing until the next exposure Battery operated lightweight fits easily into tool box or pocket e Output connector included allows a radiation output waveform to be viewed on an oscilloscope For added operator conve nience the remote sensor is available as an option e The optional remote sensor can be used when the user has the unit in their hand The
133. ficult to see even on the best mammographic system Phantom body Material Acrylic Dimensions Overall WxDxH 10 15 cm x 10 8 cm x 4 4 cm 4 in x 4 25 in x 1 75 in Biomedical Key features e Helps ensure optimum image quality and peak performance of the mammographic system Essential for MQSA compliance Complies with ACR phantom specifications and QC requirements e Contains test objects to simulate indications of breast cancer punctuate calcifications tissue fibrillar extensions in adipose tissue and tumor like masses e Ideal for monitoring the overall performance of your mammographic imaging system x ray generator film processor and screen film combination e Equivalent in x ray attenua tion to a 4 5 cm compressed average breast Optional are two 2 cm acrylic plates The addition of these two plates when combined with the overall 4 4 cm thickness of the phantom will allow the system image quality to be checked in varying thicknesses of 2 cm to 8 5 cm Both of these items are recommended by ACR in their Mammography Quality Control Procedure Optional accessories 18 237 Acrylic Plates 10 cm x 10 cm x 2 cm thick set of 2 18 205 Acrylic Contrast Test Disc 1 cm x 4 mm 89 220 Carrying Case Acrylic base 3 4 cm in thick 1 375 in Cover 3 mm thick 0 128 in Acrylic contrast test disk 1 cm x 4mm Weight 0 55 kg 1 2 1b Nylon
134. for different apertures and density subtraction Power 110 220 V 50 60 Hz Dimensions WxDxH 16cm x 34 cm x 12 5 cm 6 3 in x 13 4 in x 4 9 in Weight 3 2 kg 7 1b Film Processor Quality Assurance Optional accessories 89 424 Carrying Case 07 413 Apertures set of three 010037 Step Tablet 802013 RS 232 Interface Cable 2m 7 ft 169072 9 Pin Adapter 169071 25 Pin Adapter Included accessories 010128 Step Tablet Ordering information 07 424 Digital Densitometer 07 424 220 Digital Densitometer 220 V 07 440 Digital Densitometer with RS 232 interface 07 440 2200 Digital Densitometer with RS 232 interface 220 V 77 201TR to 77 406TS Key features Thin 3 375 in profile e Sturdy steel construction e TECH GRIP roller gravity film holding system e Centralized cluster switching e Continuous bottom film ledge e Minimal 1 8 in separation between tiers of two tiered The MAXANT TECHLINE Illuminator is a universal body design available in multiple instant on lighting configura tions including the TECHLINE 200 300 and 400 series fixtures Offered in configurations from e Engineered design easily a single panel through six serviced e Baked white enamel finish e UL listed and CSA approved e Film activated micro switch e Dual intensity available on TECHLINE 300 and 400 series only e Multi panel master switch e Surface mount hardwired e Hospital grad
135. fy the quality of x ray tube voltage accuracy linearity and reproducibility of the x ray beam as well as the dose rate Originally designed to meet French regulations The kit is ideal for use anywhere com prehensive quality assurance is needed The 07 600QC Quality Control Kit comes in two configurations The O7 600QC is the standard quality control kit and includes all of the recommended phantoms and test objects for quality control to meet regulatory requirements This kit is best paired with Fluke Biomedical s 10500AMT TRIAD TnT x ray test device allowing users to accurately test the integrity of their x ray tube The 07 600QCN is also designed to work with Fluke Biomedical s 8000 NERO mAx x ray test device This kit version includes all the components of the 07 600QC as well as sev eral additional accessories to improve the setup and ease of use while testing with the 8000 NERO mAx Both kits come in a rugged carrying case designed to easily transport and protect all of the phantoms and test object The carrying case also doubles as a safe storage compartment conve niently holding all of the delicate components Radiography Fluoroscopy Phantoms and Accessories FLUKE o Biomedical Key features e Includes all of the phantoms and test objects needed for quality control in conventional radiography applications Ideal for QC measurements of beam geometry kilovoltage and radiation quality spatial
136. g information 76 410 4130 AAPM CT Performance Phantom with Resolution Insert to 0 4 mm 76 410 4132 AAPM CT Performance Phantom with Resolution Insert to 0 2 mm CT Quality Assurance 108 Biomedical Key features e Incorporates clinically relevant lesion shape spherical and size Wee The 76 409 CT Lesion e Provides clinically relevant Detectability Phantom is par absolute HU values for soft ticularly useful to physicians tissue CT technologists and medical P S physicists who design enue have a slightly lower HU than ning protocols for abdominal background pelvic and brain CT It allows e Designed for use on all users to test various scanning conventional and spiral protocols to verify that small helical CT scanners low contrast lesions will be e Compact rugged detected This is the only way e Features three cylindrical to be sure that a CT scanner is reference plugs made of the seeing tumors that are known same material as the spherical lesions e Valid for x ray energies from 80 kVp to 140 kVp e Background Hounsfield Units to be present The use of this phantom removes any doubt as to the limit of low contrast spherical lesion detectability HU approximate liver tissue for various scan protocols e Contains clinically relevant The phantom is designed to permit complete testing of low sphere sizes of 2 4 mm contrast lesion detection when various scan or image recon 3 2 mm 4mm 4 8 m
137. g the 07 CRXW the process can be completed in under two hours A substantial productivity gain for service biomedical or physics professionals Essentially the wireless 07 QRX performs all of the functions of the 07 CRXW however CRLU and speed numbers representing the relative system speed of the CR system compared to a film screen system are displayed on a LCD readout built into the electronic cassette A pressure sensitive On Off switch activates the O7 QRX and is used to reset the meter between exposures The values may be manually entered into the software program on a laptop or PC if desired but a laptop is not required to use the O7 QRX The O07 CRXW and O7 QRX are designed to work with all major brands of CR equipment The O7 QRX QA RADCHEX is ideally suited for fast and easy daily checks of AEC and CR system exposure continuity Data obtained from daily checks can be used for trend analysis of individual systems as well as a way to monitor the balanced performance of CR systems throughout the healthcare enterprise Diagnostic X Ray Quality Assurance Instruments Biomedical X ray energy dependence Simulates relative light output of photostimulatable phosphor plate PSP within 3 over kVp range of 60 kVp to 120 kVp and a patient equivalent thickness range of 5 cm to 35 cm within specified operating rates Digital range Computed radiography light units CRLU AEC O to 800 CRLU AEC O to 8000 07 QRX
138. ght is actually 16 5 inches in order that extraneous light is eliminated when standard 14 in x 17 in film is inserted in the roller gravity grip 86 Film Handling and Storage 77 201TR to 77 406TS Biomedical Recess mounted Dimensions inches 200 series 2 lamp 300 series 3 lamp 400 series 4 lamp Viewing Wall cutout Model Shipping Model Shipping Model Shipping area Length Height wgt 1b wot 1b wgt 1b 1 panel 14 in x 17 in 14x 17 14 75 21 75 71 201TS 26 71 301TS 26 71 401TS 26 2 panel side by side 28 x 17 28 75 21 75 71 202TS 45 71 302TS 45 71 402TS 45 3 panel side by side 42 x 17 42 15 21 75 71 203TS 64 71 303TS 64 71 403TS 64 4 panel side by side 56 x 17 56 75 21 75 71 204TS 87 71 304TS 87 71 404TS 87 5 panel side by side 70x17 70 75 21 75 71 205TS 107 71 305TS 107 71 405TS 107 6 panel side by side 84x 17 84 75 21 75 71 206TS 128 71 306TS 128 71 406TS 128 1 over 1 14 in x 17 in 2x 14x17 14 75 42 15 77 211TS 39 77 311TS 39 77 411TS 39 2 over 2 2x 28x17 28 75 42 15 71 222TS 86 71 322TS 86 71 422TS 86 3 over 3 2x42x 17 42 15 42 15 71 233TS 126 71 333TS 126 71 433TS 126 4 over 4 2x56 x 17 56 75 42 15 71 244TS 165 71 344TS 165 71 444TS 165 5 over 5 2x 70x 17 70 75 42 15 71 255TS 328 71 355TS 328 71 485TS 328 crated crated crated 6 over 6 2x 84x17 84 75 42 15 71 266TS 364 71 366TS 364 71 466TS 364 crated crated crated Viewing height
139. group test pattern Each group has six bars three of which are positioned at right angles to the adjacent set The groups diminish in size from 0 63 line pairs mm 2 mm to 2 52 line pairs mm 0 8 mm By observing the radiograph and using the supplied chart showing resolution vs focal spot size the nominal focal spot dimension in mm can be determined Dimensions stand WxH 6 35 cm x 15 24 cm 2 50 in x 6 in Weight 0 11 kg 0 25 1b 44 Diagnostic X Ray Quality Assurance Instruments FLUKE o Biomedical 07 501 to 07 555 Test Patterns X Ray Test Patterns for measuring resolution Fluke Biomedical offers a range of patterns for use in a variety of desired applications The sector test patterns are 0 4 and the group test patterns have varying numbers of line pair groups Lead thicknesses are limited by the resolu tion with a maximum thickness of 0 1 mm for test patterns up to 5 LP mm Radiopaque numbers indicate the resolution in LP mm of each group 0 05 mm Pb Gi Ionia p tat tensluul Hil E o PAU 15 20259 6 Specifications and ordering information Range of Number of Lead foil Dimensions resolution groups thickness inmm in LP mm in mm X Ray Test Patterns for measuring resolution 07 501 2000 1 0 to 4 8 16 0 1 110 x 40 07 501 1000 Ultra High Precision Pattern same
140. h resolution images of smaller areas of interest The 76 904 MRI Surface Coil Phantom was specifically designed for acceptance testing and routine QC of surface coils It provides the proper geometry not found in conventional head or body phantoms The 76 904 is constructed of non magnetic Plexiglas It is rectangular in shape contains three inserts and is designed to be filled with an MRI signal producing solution The void between the inserts provides a fully flooded area Outer dimensions WxDxH 33 02 cm x 15 24 cm x 17 46 cm 13 in x 6 in x 6 875 in Inner dimensions WxDxH 30 49 cm x 12 7 cm x 15 24 cm 12 inx 5 in x 6 in Weight 3 61 kg 7 96 lb Developed by Seong Ki Mun Ph D Department of Radiology Georgetown University Hospital Washington DC MRI Quality Assurance Biomedical Key features e Provides proper geometry not found in conventional head or body phantoms Accurately evaluates e High spatial resolution e RF signal brightness profile e Slice thickness e Slice to slice gap e MTF evaluation e Magnetic field uniformity e Gradient linearity e Image artifacts e And more 116 Biomedical A wide range of tests are provided by individual phantom sections High resolution hole pattern oooo000000 oooooo00000 oo Five holes 2 mm x 2 mm Seven holes 1 mm x 1 mm Nine holes 0 75 mm x 0 75 mm Eleven
141. h lower dot ment plates in position Note that the grooves on the side and upper cross alignment plates of each plate ensure the correct orientation of the plates in position NEMA Base with lower alignment plate dot plate in posi tion Note that the leading edge of the plate fully engages the cutout in the rear leg Radiography Fluoroscopy Phantoms and Accessories Plate identification and stacking order Biomedical Additional Lead Plate if needed oy OF oF image oF oF Receptor os os On F os os 05 HP maT 1 o4 oo oa pa oz tir oF Oz LiF mi t wI Di i oa T3 og on Os as pS gt Da OG ar bss or Dose Measurement Point 25 mm below phantom Ssoerter Ray Tube Maximum Output 5 cm 10cm 20 cm 30cm 30 cm from image Receptor NEMA 00 Configuration Revised 1 Sep 00 SB Irpa Material Thickness tolerance Comments PMMA plates 1mm Aluminum 0 5 mm Type 1100 Piano wires Commercial steel These are standard items Lead pins 1lmm Lead plate 0 1 mm Copper plate 0 1 mm Iodine t5 Reagent grade tolerance is concentration in epoxy PC boards Solder covered traces thick enough to be seen through 30 cm of PMMA Radiography Fluoroscopy Phantoms and Accessories Low contrast holes in aluminum disk ach dia 0 375 in Hole depths Test Tool Plastic thickness 0 34 in Aluminum disk 0 25 in 0 0063 in 2 in
142. h pure alu minum When doing HVL measure ments with a mammography unit it is recommended that the highest purity aluminum be used This set of six attenuators satisfies this recommendation because they are 99 9 pure type 1145 Dimensions WxDxH Weight UNIFORMITY 07 434 21 5 cm x 21 5 cm x 1 2 cm 8 5 in x 8 5 in x 0 375 in 1 3 kg 3 1b Dimensions WxDxH Weight 10 cm x 10cm x 0 1 mm 4 in x 4 in x 0 004 in 0 06 kg 0 15 1b Designed by Joel E Gray Ph D Professor Emeritus Department of Diagnostic Radiology Mayo Clinic Rochester MN 55905 Manufactured under licensing agreement with Mayo Foundation for Medical Education and Research 16 Radiography Fluoroscopy Phantoms and Accessories Biomedical Key features 07 656 e Recommended as part of the Image Compression Study being conducted by the American College of Cardiol ogy ACC DICOM Committee e Selected by the ACC as the image quality criteria for digital imaging 07 434 e Recommended for mammography e 99 9 pure for accurate HVL measurements Biomedical Key features e Designed to yield a quantitative assessment of fluoroscopic threshold contrast The 07 645 Fluoro Test Tool is a fluoroscopic contrast reso lution device that employs a target arrangement designed to reduce ambiguity and difficulty associated with employing a sequential array of targets with small difference
143. hantoms are manu factured from a water based polymer called Zerdinee and housed in rugged ABS containers that minimize desiccation The background is calibrated to mimic the ultrasound characteristics of human liver tissue Unlike other phantom materials Zerdine is not damaged by changes in temperature 84 555A is a volumetric target phantom and contains a small egg and a large egg There are two scanning surfaces and the targets are off centered within the background material Depending upon what side is scanned the test objects are located at distances ranging from 2 cm to 6 cm from the scan ning surface 84 555B is a wire target phantom that can be used to measure linear and curved dimensions as well as perimeters volumes and surface areas It may also be used to determine image uniformity and depth of penetration The phantoms come with a rugged carrying case a copy of the above referenced AIUM publication as a user s guide and han dling instructions Ultrasound Quality Assurance 120 84 555A Material Attenuation coefficient Zerdine solid elastic water based polymer Freezing point O C 32 F Melting point above 100 C 212 F 0 5 dB cm MHz 0 05 dB cm MHz Speed of sound 1540 m s 6 m s Targets 9 dB 3 dB lower than background Depth of targets 2 cm to 6 cm from scanning surface Volume of targets Small egg 6 7 cc Large egg 65 0 cc Scanning membrane
144. he effects of temporal averaging The device contains five steel wires of different diameters 0 022 in 0 016 in 0 012 in 0 009 in and 0 005 in or 0 56 mm 0 41 mm 0 30 mm 0 23 mm 0 13 mm Two lead dots are used to evaluate lag and recursive filtering Rotation speed is 30 revolutions min The linear velocity of the outer lead dot is 200 mm sec The rotating disk replaces the central test plate at the isocenter See Figure 5 Dosimetry tools The NEMA Cardiology Phantom entrance exposure rate is measured at a standardized position in front of the entrance surface of the phantom 25 mm This position is considered an acceptable choice for this particular benchmark ing phantom The phantom can also be configured to generate the FDA measuring point 30 cm in front of the image receptor See Figure 6 Working thickness range The ability to image structures overlaid by bone or air Systems with inadequate single image latitude are unable to do this in bright air or dark bone portions of the image The NEMA Cardiology Phantom contains eight cylinders composed of different heights of air aluminum and plastic These cylinders are calibrated for a total 20 cm phantom thickness A 50 mm deep air challenge target overlaps the four air cylinders The bright side dynamic range is deter mined by how many of these targets are seen A 5 mm lead challenge target overlaps the four aluminum cylinders The dark side dynamic range is determined
145. he platen is raised and a sheet of film is inserted beneath it until the film stops are reached The platen is lowered and the exposure switch is depressed An audible buzzer is activated during the exposure To prevent double exposures a two second delay is engaged before the next exposure can be made When battery replacement becomes necessary the unit will not expose film Battery life is approximately 10 000 exposures Processor variations are monitored by comparing the control film to previously processed films Speed contrast and base plus fog values can be graphically plotted for easier comparison Specifications Light source Dual color electroluminescent Blue 455 nm 10 nm green 520 nm 10 nm Repeatability 0 04 OD log exposure from unit to unit Stability 0 02 OD log exposure per year at 10 C to 45 C Exposure area 21 steps each 5mm x 10mm Tablet densities 0 05 OD to 3 05 OD in 0 15 OD increments Exposure time Adjustable 50 ms to 500 ms typical Exposure adjustment Separate external screwdriver adjustments 0 5 OD on each color Controls Push to expose button buzzer monitor and two second delay to prevent double exposures Blue Green rocker switch Power switch none required Unit draws no power on standby Power requirements Two 9 V alkaline transistor batteries Optional ac power converter Approximate battery life 10 000 exposures
146. he tissue simulation properties for these slabs are maximized at 20 keV 28 kVp The glandular equivalency of this material is 45 in the mammographic range Biomedical Mammography Collimation Assessment Test Tool The 18 303 Mammography Collimation Assessment Test Tool is a self contained precise QA tool that gives you instant measurements by simply viewing the image The 18 303 Mammography Collimation Assessment Test Tool is simple to use Just follow the exact instructions contained in the ACR Mammography QC Manual for the Collimation Assessment However instead of using all those hard to find coins you use the 18 303 The O point of the metal ruler is placed at the edge of the light field The compression paddle rests on top of the appropriate size plastic peg 1 7 mm and 2 2 cm pegs are included to accommodate different cassette thicknesses and the alignment ruler generously sized at 3 cm in both directions fits snugly against the edge of the paddle It couldn t be much sim pler or much quicker Mammography Collimation Assessment Test Tool shown in position Specifications Dimensions WxH 24 cm x 30 cm 9 45 in x 11 81 in Weight 0 57 kg 1 25 1b Designed by Carol Mount R T R M Supervisor of Mammography Mayo Clinic Rochester MN 55905 Manufactured under licensing agreement with Mayo Foundation for Medical Education and Research Mammography
147. holes 0 5 mm x 0 5 mm Hole depth 9 mm Folded step ramps e Slice thickness profile e Interslice gap e Slice orientation evaluation Step interval 1 mm Range 30 mm Step size 10x 10 mm Matching pair of ramps e Precision slice definition evaluation 160 mm run 40 mm rise 4 1 ratio 0 5 in thick Star pattern a e Qualitative MTF evaluation e Resolution e Asymmetric resolution e Image artifacts Thirty 3 wedges 60 mm x 30 mm covering a 180 fan shape 0 785 mm gap at narrow end 3 mm gap on wide end Square grid e RF intensity profile e Magnetic field uniformity e Gradient linearity e Aspect ratio Dimensions 0 5 x 0 5 gird of 12 in x 6 in x 0 375 in thick Flood section e RF signal uniformity e Single T and T values Dimensions 12 in x 5inx6in Optional accessories 716 903 7000 Copper Sulfate 1 gm 1 MRI Quality Assurance Five section insert Sections Folded step ramps Segments provided two 60 The 76 903 MRI Multipurpose Phantom monitors the overall performance of an MRI system The parameters that can be measured include slice thick ness slice orientation interslice gap magnetic field homoge neity radio frequency signal uniformity spatial resolution in positive and negative con trast and modulation transfer function MTF The phantom can also be used to evaluate quadrature setting b
148. ier and cine measurements Construction 96035B Graphite coated acrylic parallel plate air vented 96020C Composite graphite filled thermoplastic parallel plate air vented Volume 96035B 15 cm 96020C 150 cm Diagnostic X Ray Quality Assurance Instruments 10100AT 10500AT and 10500AMT 10100AT TRIAD TnT Kit continued Ion Chamber Units Effective Range Resolution Step Size 15 cc R 00 p to 20 ly R s 00 p to 20 lp R m 5 m to 1200 50u R h 0O m 72k lm R f 2 u to 333 m 0 02 p Gy uto 175 m 0 01 p Gy s p174m 0 01 p Gy m 50 p to 10 5 0 5 y Gy h 1 m to 630 0 01 m Gy f 0 02 u to 2 9m 0 2 n 150 cc R 10 p to 2 0 1 p R s 10 to2 Olu R m 0 5 m to 120 5u R h 10 m to 7 2 k 0 1m R f 0 2 u to 33 m 0 002 u Gy 0 1 u to 17 5 m 0 001 u Gy s 0 1 y to 17 5 m 0 001 u Gy m 5 u to 1050 m 05 p Gy h 0 1 m to 63 0 001 m Gy f 0 002 p to 290 p 0 02 n 150 cc VLDR R s 2 u to 2 Oly R m 0 1 m to 120 5u R h 2 m to 7 2 k 0 1m R f 0 04 to 33 m 0 002 p Gy s 0 02 p to 17 5 m 0 001 p Gy m 1 y to 1050 m 0 05 p Gy h 0 02 m to 63 0 001 m Gy f 0 4 n to 290 p 0 02 n Electrical Units c 1 pto 100n 0 01 p A 1 pto 100n 0 01 p Values for ion chambers are calculated using nominal sensitivities 15 cc 2 4 x 108 R C 150 cc 2 4 x 107 R C Very Low Dose Rate effective range at 5 resolution steps
149. image Provides information about the imaging performance of the whole system 225 squares 15 rows and 15 columns In each square either one or two spots the images of the holes are present The first three rows show only one spot while the other rows have two identical spots one in the middle and one ina randomly chosen corner See graph The optical densities of the spots are higher than the uniform background In the contrast horizontal direction the depth of the holes increases logarithmically and the image shows 15 columns of spots with increasing contrast Performance comparison Comparison of the performance of several observers is also possible The better performing observer produces a CD curve more to the lower left part of the image Dimensions WxDxH 26 4 cm x 26 4 cm x 0 76 cm 10 4 in x 10 4 in x 0 3 in thick Weight 1 34 kg 3 1b 66 Radiography Fluoroscopy Phantoms and Accessories Biomedical Biomedical O7 6G05 7777 The 07 605 7777 CR DR DIN Test Tool is a timely and valu able solution to the image quality maintenance problem Technologists radiologists and physicists can easily perform quick and reliable assessments of their CR DR systems Today s new image acquisi tion chains are considerably more complex than conven tional screen film systems Computed Radiography CR Digital Radiography DR sys tems involve special processing for
150. imensions WxDxH 28 cm x 12 5 cm x 20cm Weight 5 5 kg 12 1b 1US Patent 5196343 CT Quality Assurance 114 76 907 ppp 2s 76 908 76 907 Dimensions WxDxH 76 907 and 76 908 76 907 MR Uniformity Linearity Phantom AAPM The 76 907 Uniformity Linearity Phantom was designed to conform to AAPM MRI specifications This large flat flood phantom can be filled with an MR signal producing solution The orthogonal array holes contain orientation refer ence markers and the flood section has an image artifact cylinder 76 908 MR 3D Slice Thickness High Contrast Resolution Phantom AAPM Various sections are arranged within a cubical shape to make the 76 908 truly si 3D Slice Thickness Resolution Y Phantom contains slice thick N ness measuring sections and TE a void between the inserts to allow for a signal producing solution Slice thickness and g resolution information can be p obtained in all three direc tions transaxial coronal and sagittal without moving the phantom 33 02 cm x 33 02 cm x 10 16 cm 13 in x 13 in x 4 in Biomedical three dimensional The 76 908 Weight 5 3 kg 11 68 lb 76 908 Dimensions WxDxH 15 24 cm x 15 24 cm x 12 7 cm 6 in x 6 in x 5 in Weight 1 56 kg 3 46 1b Phantom configuration Resolution section Six sections Square holes 0 5 mm 0 75 mm 1 mm and 2 mm Hole depth 0 5 in
151. imilar manner It can also be connected to 10 MQ input impedance dc digital voltmeters or 10 M 10 X scope probes The three anode connections are individually wired for use on the latest GE CT Scanners 07 469 is designed with the same dc resistance values as the General Electric C1515A and 46 15496681 Those voltage dividers have a frequency response valid to 1000 Hz 07 469 performs as a frequency compensated replacement for those dividers and is usable at high frequencies as well as short exposures With a well characterized rise time 07 469 is suit able for use in radiographic cine pulsed and mammographic applications 87 476 Carrying Case 07 478 High Voltage Cable 5 ft DC accuracy when operated 1 into rated load impedance Divider ratio Divider resistance Switch selectable 10 000 1 or 1 000 1 100 megohm Load impedance 1 megohm 10 000 1 or 10 megohm 1 000 1 Voltage range O kVp to 150 kVp DC accuracy 1 or better 10 kV to 75 kV per side Frequency response DC to 1 kHz 3 to 100 kHz 5 Insulation Oil filled may be operated continuously HV terminals Federal standard 3 pin 4 pin optional for cathode Output terminals BNC Oil tight selector switch Dimensions LxH 25 cm x 30 5 cm 10 in x 12 in Weight 14 5 kg 32 lb 40 Diagnostic X Ray Quality Assurance Instruments Biomedical Key features e A qual
152. in 34 Diagnostic X Ray Quality Assurance Instruments Biomedical Key features e Entrance skin exposure measurements ESE Fluoroscopy exposure measurements Exposure checks radiographic mR mAs Beam quality half value layer HVL mAs reciprocity mA station checks plus many others depending on the remote external chambers used The American College of Radiology ACR recommends this type of product in their quality assurance program Fast and easy use Battery operation and built in detector eliminate setup time Measures dose up to 2 R dose rate up to 20 R min Energy response is 5 from 30 kVp to 150 kVp for the RAD CHECK PLUS internal chamber Optional remote chambers for mammographic and cine imaging systems Extremely compact 15cmx 15 9cmx7cm 6 in x 6 25 in x 2 75 in weighs only 0 51 kg 1 125 1b Optional accessories 6000 528 Radiographic Ion Chamber 6000 529 Mammographic Ion Chamber 6000 100 CT Ion Chamber 6000 530B Image Intensifier Ion Chamber 89 525 Carrying Case holds RAD CHECK Plus and accessories CE O06 526 5240 This state of the art electrom eter is designed for measuring dose and rate under high and low dose rate conditions It is excellent for cardiac cath and fluoroscopy and the perfect choice for tight budgets RAD CHECK MICRO R tech nology gives you the ability to measure dose and rate in fluo roscopy with the accuracy and reliabili
153. in x 4 72 in x 3 54 in Weight 0 44 kg 1 1b Ultrasound 1US Patent 5196343 Mammography Quality Assurance 18 230 1000 18 230 Series The 18 230 Series GRID VIEW System enables the breast biopsy procedure to be per formed faster easier and more accurately than ever before With GRID VIEW there is no longer an open exposed spec imen which must be handled a number of times There is no longer a delay between the specimen being brought down from surgery to radiology to be placed on a makeshift imaging board And with GRID VIEW there is no longer any guess work as to the orientation of the specimen The GRID VIEW System is composed of a sealable plastic container that contains a radiopaque grid which is lettered and numbered for accurate orientation Once the top of the GRID VIEW container is closed the specimen is compressed onto the grid making it stationary and ready for transport Using GRID VIEW makes your job easy 1 Biopsy tissue is placed in the GRID VIEW container 2 GRID VIEW container is delivered to radiology for image confirmation 3 GRID VIEW container with biopsy is delivered undisturbed to pathology with the x ray image 4 Specimen is compared with x ray image by pathologist Weight 0 44 kg 1 1b Mammography Quality Assurance Biomedical Key features e Reduces surgery time through improved imaging turnaround e Improves communication between surgery rad
154. ing inter changeability to customize the instrument to a particular measurement requirement The 660 instrument is suitable for use for energies ranging from mammography through 1 3 MeV The 660 measurement readout is part of a complete x ray and CT exposure mea surement instrument that saves time and effort during routine diagnostic quality assurance measurements This portable and light weight readout device with large three digit LED display can be used with any of the four optional interchangeable ion chamber based probes to cover a range of 1 0 uR to 100 R in the exposure mode and 0 1 mR min to 1000 R min in the rate mode The 660 readout can be line operated or powered by NiCad rechargeable batteries Each 660 Series ion chamber based probe contains an elec trometer that permits probe calibration independent of the readout The ion chamber current signal is then digitized and this digital signal is then transmitted over the cable to the readout resulting in a virtually noise free transmission of data unaffected by cable length or stress Cables are available up to 76 meters 250 feet Applications The 660 X Ray and CT Exposure Measurement Instrument is suit able for in beam and scatter exposure and exposure rate measurements of diagnostic x ray beams mammographic range x ray machines as well as CT output measurements depending on the ion chamber based probe s selected The ease of por tability of this instrument makes it a
155. iology and pathology e Eliminates physical handling of specimen in radiology e Reduces exposure to blood borne pathogens e Eliminates the need for needles or wires e Meets all OSHA requirements for specimen handling 18 230 2000 18 230 3000 18 203 and 18 224 18 203 Mammography Phototimer Consistency Test Tool The mammographic unit s auto matic exposure control should be capable of maintaining optical density within 0 15 OD as the voltage is varied from 25 kVp to 35 kVp and as breast thickness is varied from 2 cm to 8 cm for each technique Test images taken of uniform phantoms of varying thicknesses should not differ by more than 0 3 OD from each other These tests should be carried out over the kVp range customarily used by the mam The 18 203 Phototimer Consistency Test Tool is available in two materials acrylic and for more accurate results breast tissue equivalent BR 12 material Both are supplied in uniform 2 cm slabs to produce thicknesses of 2 mm 4 mm 6 mm and 8 cm 18 203 mography center SS ee i TAU A 18 224 18 224 Mammography Phantom Material The American College of Radiology s Committee on Quality Assurance in Mammography Medical Physicist s Manual recom mends as part of the required test equipment the 18 224 Mammography Phantom Material This material is best suited for testing automatic exposure control AEC collimator assessment and artifact evalua
156. iomedical Better products More choices One company Your authorized Fluke Biomedical distributor Fluke Biomedical 6045 Cochran Road Cleveland OH 44139 3303 U S A Fluke Biomedical Europe Science Park Eindhoven 5110 5692EC Son The Netherlands For more information contact us In the U S A 800 850 4608 or Fax 440 349 2307 In Europe M East Africa 31 40 267 5435 or Fax 31 40 267 5436 From other countries 1 440 248 9300 or Fax 1 440 349 2307 Email sales flukebiomedical com Web access www flukebiomedical com 2008 2009 Fluke Biomedical All OEM company trademarks are implied Specifications subjectto change without notice Printed in U S A 6 2009 3077923B C EN N
157. ion Into isic 20 5 i ek eee 126 Diagnostic X Ray Quality Assurance Instruments Biomedical The TNT 12000 X Ray Test Device is the newest and most versatile instrument available for measuring key x ray imaging parameters It sets up in seconds and measures kVp dose dose rate time and half value layer HVL in a single exposure A totally wireless ZigBee interface enables quick and easy setup and the wireless detector can be used with the companion wire less display or a laptop computer X ray imaging QA calibra tion and maintenance in today s demanding digital environment require very high produc tivity and compliance with local and regional regulations The TNT 12000 delivers high productivity through 100 wireless connectivity to either a display which instantly responds with all values in a single exposure or a laptop where measured values are dis played and categorized in organized templates Instant HVL with just a single exposure further enhances productivity Featuring all in one exposure measurements and ZigBee wire less communication combined with the rugged reliable and accurate design that is a Fluke trademark the TNT 12000 is truly a new breed of non invasive x ray test tool TNT 12000 is ideal for use by OEM factory and field service engineers independent service organizations physicists biomedical and clinical engi neers and local and regional field inspectors of x ray imaging equipmen
158. ise fall of waveform 5 Range Fluoroscopic Measured over one second interv 10 mR to 10R als during fluoro exposure Accuracy 5 Range Detectors kV CsI photodiode pair measures 0 5 to 200 R min x ray transmission through differential attenuators Time Computed from kV waveform stored in memory against quartz crystal time base Exposure Parallel plate ionization chamber Volume 36 cm Window 38 mg cm 18 9 cm polycarbonate Calibration Reference to a NIST traceable voltage divider and a calibrated exposure monitor during irradiation Diagnostic X Ray Quality Assurance Instruments Biomedical Key features e Measures kVp maximum kVp average kVp effective dose and time in one exposure e Compact lightweight design e Displays R or Gy e External ion chambers for Mammo CT image intensifier and phototiming measure ments e Automatic exposure reset for hands off operation e Rechargeable Ni Cd batteries provide more than six hours of continuous service e RS 232 computer interface e Storage scope output for real time waveform display e Reversible display for fluoro measurements 24 Physical Display Controls 16 character dot matrix LCD Model 4000 Five rocker switches On Off Power switch Radio Fluoro Select radiographic or fluoro operation High Low Select for sensitivity Roll Roll thru data Exposure All
159. ity control tool for ensuring consistent color and grayscale video VeriLUM is an innovative tool display performance for ensuring consistent dis Can be used for acceptance play monitor performance It testing provides an easy and efficient Calibrates luminance to sa conform with DICOM Part way to judge Whether a dis 14 Grayscale Standard play system is continuing to Display Function function normally or needs e Supports Microsofte Windows adjustment or replacement 2000 XP and Vista operating VeriLUM can be used for systems acceptance testing of a CRT or e Each VeriLUM package LCD display system includes pod and cd rom with version 5 2 software and user guide e Applicable to CRT and LCD displays It also provides a quick visual check for the user A SMPTE test pattern is displayed on each monitor If the gray scale range and stability is adequate C E and if all the monitors have essentially the same look and feel then the display system is ready for use Bitmaps DICOM images e g AAPM TG 18 can be displayed VeriLUM makes a rapid set of measurements of the display luminance for tracking consistent performance over time These measurements take less than 30 seconds per monitor and the history chart can be printed when hard copy documentation is needed VeriLUM can be used to perform gamma correction in con formance with the DICOM Part 14 Grayscale Standard Display Function or any other user define
160. ivider and provides accurate readings for the range of 50 kVp to 150 kVp Four optional filter packs are avail able for use with the 35080M Non Invasive kVp Divider for CT mammographic and mobile applications 10100AT 10500AT and 10500AMT Biomedical 35080M Non Invasive kVp Divider continued Environmental requirements Temperature range O C to 35 C Relative humidity 20 to 80 Storage temperature 35 C to 50 C Orientation Power requirements Long axis of the 35080M Non invasive kVp Divider oriented perpendicular to axis of x ray tube to eliminate heel effect 9 V battery 50 hours operation battery check function connects battery to output terminals for voltage measurement Dimensions LxWxH 6 cm x 9 cm x 21 cm 2 375 in x 3 5 in x 8 25 in Weight 0 68 kg 1 5 1b 35035 mA mAs Meter Controls Accuracy 1 Power mA mAs switch 2 Reset switch 3 Range switch 200 mA mAs 2000 mA mAs and 20 mA range settings 4 ac dc switch 1 of reading two least significant digits for all ranges Environmental requirements Temperature range 5 C to 35 C Relative humidity 0 to 80 Display Liquid crystal display LCD 3 5 digit 5 in H 13 mm Input Storage temperature 20 C to 50 C Two banana jacks Power requirements Dimensions LxWxH 9 V alkaline battery with easy replacement 15 cm
161. l elapse tt e 4y m am j Benj f ini y j nan ak The TRIAD Toolkit for Excel is a complete software package for the TRIAD that includes an Excel Add In called TRIAD Tool and Excel templates used to evaluate the performance of radiographic mammographic and fluoroscopic x ray machines The TRIAD Tool collects measured results from the 35050A and 35050AT Dosimeter and places the data in the active Excel worksheet In addition the TRIAD Tool may be used to acquire and graph kV waveforms from the TRIAD as well as remotely control the TRIAD Dosimeter Diagnostic X Ray Quality Assurance Instruments 10500EXL Dirai pim Fema H ras Hame Pack X homa 2i TR yp tered Fiore r each control follows The TRIAD Tools menu provides an interface to remotely control the TRIAD select filter packs chambers units retrieve kV waveforms open templates and change the options A description of Connect disconnect Connects or disconnects the TRIAD to the communications port Connect instructs the TRIAD Tool to read configuration information such as the filter packs chambers and units Options Several options can be specified including COM port temperature pressure and frame rate Measure Sets the TRIAD up for a single exposure using the selected filter pack chamber and unit Auto reset Informs the TRIAD Tool to automatically reset the TRIAD for another exposure allowing a series
162. l image intensifier measurements to unattenuated direct beams automatic offset compensation and nonlinear filtering Autoranging provides five decades of sensitivity ranges Display updates once per second kVp Rate Full sensitivity dose Very low dose rate VLDR This mode is only for making very low dose rate measurements Nonlinear digital filtering and autoranging provide five decades of sensitivity ranges Display updates once per second In this mode automatic current offset and drift compensation are disabled As a result the system can display very low dose rates Power requirements Battery life 30 hours with six AA alkaline batteries automatic power down after user selected period of unattended operation 5 min to 255 min AC adapter supplied with each 35050AT Note When the ac adapter is in use the auto power down feature is disabled providing continuous operation User selections for ion chamber units kV filter pack temperature pressure and frame are stored in nonvolatile memory before automatic turnoff eliminates manual reselection at power up Bias voltage supply Fixed electronic bias 300 V bias voltage removed from triaxial input connector at instrument turnoff Customization Allows user to modify contents of nonvolatile memory including ion chamber and KV filter pack conversion factors temperature and pressure units radiation units and power down interval A field customiza
163. lluminance The O7 621 is a highly accu rate instrument designed to measure both illuminance the amount of light falling on a sur face in lux lumens per m and luminance the amount of light emitted from a surface in nit candela per m The 07 621 easily and quickly verifies that an x ray collimator light and or CT system light source used for patient alignment and localization is in accordance with regulations and guide lines It also measures the brightness and uniformity of an x ray view box quickly detecting non uniformity which may appear as artifacts causing misdiagnosis This battery operated pho tometer has a bright LED display and only two operating controls Measure for taking a reading and Range to adjust the meter display to the light level being measured Capabilities Illuminance measured in lux foot candles or luminance measured in candela m2 nit Readout display Three digit LED 0 25 in high Range 0 1 to 999 000 lux or nits candela m2 equivalent to 0 01 to 99 000 foot candles Accuracy Within 7 of full scale range for light sources between 2500 and 5400 Kelvin Electrical accuracy 1 plus two digits Sensor Silicon photodiode with photometric filter Response curve shape Close match to CIE photopic response curve Power requirements Type A 76 alkaline button cells or silver oxide equivalents Dimensions WxDxH 7 cm x 3 cmx
164. lly isolated from the collector area Connector Side mounted triaxial two lug BNC connector Calibration 96020C Standard Calibration Standard calibration performed at H60 NIST defined as 60 kVp first HVL of 6 0 mm Al homogeneity coefficient of 94 96035B Standard Calibration Standard calibration performed at one diagnostic and one mammographic beam quality calibration factors normalized to 22 C and 760 mmHg Diagnostic Unattenuated Beam Calibration on diagnostic side of chamber is performed at M80 NIST defined as 80 kVp first HVL of 2 97 mm Al homogeneity coefficient of 57 Mammographic Beam Calibration on mammographic side performed at Mo Mo28 NIST defined as 28 kVp first HVL of 0 332 mm Al homogeneity coefficient of 74 3 or MV30 PTB defined as 30 kVp first HVL of 0 337 mm Al 35080M Non Invasive kVp Divider Range 50 kVp t0150 kVp using only the wide range radiographic filter pack 37617 range and versatility extended with use of special optional filter packs Accuracy 2 of reading in the range of 50 kVp to 150 kVp exclusive of linearity filtration and gain effects linearity corrections automatically applied when using 35080M Non invasive kVp Divider with either the 35050AT Dosimeter or the 199XRAY Medical Scopemeter Response time 150 ps 10 to 90 Calibration Internally generated signal provides calibration check Minimum time for valid reading 1 ms
165. lts e Lightweight and portable e Reads grayscale up to 4 OD e Two aperture choices 1 mm and 2mm e Easy touch pads e Battery operated e Easy read display Optional accessories 87 443 1000 Battery Charger 87 443 2140 Battery and Charger Kit includes four AA NiCad batteries and one battery charger 89 443 Carrying Case Included accessories 010128 Five Step Density Tablet 89 443 Carrying Case Ordering information 07 443 Handheld Deluxe Digital Clamshell Densitometer Handheld Dual Color Sensitometer ral This compact precision instru ment is ideal for maintaining consistent high quality film processing By evaluating control films on a daily basis the technologist can identify processor variations before they affect clinical radiographs Also processing conditions in multiprocessor depart ments may be standardized In the past this was difficult in departments using varied film screen combinations in different areas With this sensitometer proper exposure of either blue or green sensitive x ray film is easily accomplished with no need for internal adjustments The Handheld Dual Color Sensitometer features a 21 step den sity wedge with 0 15 OD increments The 21 density gradient steps are numbered for convenience An innovative dual color electroluminescent light source provides precisely controlled repeatable exposures The desired color is selected with a front panel switch To make an exposure t
166. luminescence designed to pro provides consistently even vide a reliable solution to most light diffusion viewing needs The FLEXI GRIP a Gesign ey Film Holding System handles p r all film thicknesses wet or dry ed soca a and requires no field adjust e UL listed and CSA approved wi ment The high gloss finish e Centralized cluster switching is standard hospital white geo acl ha compatible with most medical Gee Ero Svea facility decors The shatterproof translucent viewing panel pro e Multi panel master switch vides consistently even light diffusion and is easily removed for optional cleaning and maintenance And the bottom film ledge allows for o SMECE ma ne SAS reading of multiple film sizes on a viewing area This illuminator optional is the reliable light source for the value minded customer e Hospital grade plug optional Applications The Maxant MVP Illuminators are ideal for use in clinics and private office settings Rugged and durable MVP Illuminators combine quality and affordability in one diagnostic viewer Each viewing area has a 110 V power supply Each viewing area contains two 15 W daylight fluorescent lamps which are controlled by two ballast Safety rating All ballasts are UL listed and C S A approved Each MVP viewing panel 110 V to 124 V 60 Hz 0 7 A per panel Two lamps F15T8 D or equivalent Ground chassis with 3 wire 6 ft cord and NEMA 5 15 2 pole 3 wire gr
167. m struction parameters are varied These include collimation oe 9 5 mm in pitch reconstructed field of view reconstruction algorithm z axis patient s long axis interpolators kVp mA and rotation time This lesion detectability testing can be applied to protocols designed for imaging of the liver spleen pancreas kidneys and adrenal e Spheres are 5 HU 10 HU and 20 HU below background HU e Carrying case is designed for use as a phantom support glands It can also be used for mass detection in the brain during scanning procedure Low contrast sphere 2 4 mm 3 2 mm 4 mm 4 8 mm 6 3 mm and 9 5 mm diameters Disk dimensions 18 cm x 4 cm thick rane i Phantom dimensions 20 cm long x 18 cm O Weight 5 4 kg 11 9 1b 6 Note The CT Lesion Detectability Phantom is a tissue equivalent test object that consists of an 18 cm diameter right circular cylinder with a CT value of 50 HU at 120 kVp Within the phantom is an 18 cm diameter 4 cm deep right circular void in which a soft tissue equivalent disk containing low contrast spheres can be placed The cylindrical void is in a plane containing the z axis of the scanner The soft tissue equivalent disk also has a background CT value of 50 HU Embedded within the disk are three sets of simulated spherical lesions One set is 5 HU below background a second set is 10 HU below background and the last set is 20 HU below background Each set contains
168. m menu routines means setup in seconds Fluke Biomedical ruggedness provides reliable operation It s tough 40 kHz sampling rate to ensure accuracy with the most difficult applications Global support network delivering prompt service and peace of mind to Fluke Biomedical customers worldwide are instantly available on the hand held display or on the user s laptop The latter appli cation places measured values into templates that are stan dard with the Excel software provided with TNT 12000 Because the TNT 12000 Excel package is a spreadsheet users can customize their templates and create their own reports to send to others Accuracy reproducibility and reliability are also critically important and Fluke Biomedical is the industry standard customers count on to deliver uncompro mised performance OAA kVp measurements TNT 12000 Radio Fluoro modes Units kVp Average average of peaks during a specified interval kVp Max highest peak during a specified interval PPV peak practical voltage Ranges 40 kV to 150 kV Mammo modes Mo Mo 22 kV to 35 kV standard calibration Rh Rh 25 kV to 49 KV optional calibration Mo Rh 22 kV to 40 kV optional calibration Mo Al 22 kV to 49 kV optional calibration Rh Al 25 kV to 49 kV optional calibration W Rh optional calibration W Ag optional calibration Resolution 0 1 kV Accuracy Radio Fl
169. m o e eeeeeeeceeceeseceeeeeeeeeeteeeeeeeteeeeeeeteeetees 63 07 652 CDRAD Contrast Detail Digital and Conventional Radiography Phantom 65 O7 605 7777 CR DR DIN Test TOO siisii iai is 01 647 R F QC Phant i ericnnatn nra ae raa A SEAE EEEE Lad EEEE FLEES 07 643 Contrast Imaging Phantom io c cc ccccccutctccscscactescesetcceeeseieaeccdesssacennecceeiaiboesddiststaeeescseneetinnestases 07 653 Fluoroscopic Imaging Test Phantom 5 76 2 Series Diagnostic X Ray Phantoms a 76 025 CDRH Dental Image Quality Test Tool ee cesssceceseeeseseseeseeeseseseseseneneeceseeseaeaesetesenseeeeseses 73 76 606DX ATOM MAX Diagnostic Head Phantom 0 ees eese cee eeseaeeeenseeeaeeeeneeeaseneneeeeenee 75 07 656 Cardiac Digital Imaging Cine Video Quality Control Phantom and Patient Identifier 76 07 434 Ultra High Purity HVL Attenuators oo eceeeceeeeeeeseeeeeeseseeeseeeeeeeeeseseeeaeaeesaeseaeeeseseaseeeeeeeeeteteees 76 07 645 FIUOLO Test TOO iiiisssiriniisiisrsi iriiria dispi aaia aiiai ia TI 07 101 2000 RADCOMP X Ray Entrance Skin Exposure SoftWare seesssssereserieerierrierrreriserrennne 78 07 638 Fluoro Contrast Test Disks isi ssissssiivissssrrisi scsasinanissnssssannnaisnin i 07 614 8080 Adult Cine Attenuator Contact us Fluke Biomedical 6045 Cochran Road Cleveland OH 44139 3303 U S A Fluke Biomedical Europe Science Park Eindhoven 5110 5692EC Son The Netherlands For more information contact us In the U S A
170. module system control logic and a spare HV power supply The entire system has a modular design for add on capability inter changeability and ease of maintenance Applications The only sure way to demonstrate compliance to leakage radia tion standards is with a full spherical scan of the x ray emitting products such as diagnostic x ray tubes X ray leakage tests are made easy for x ray tube manufacturers and tube reloaders A rapid 100 production test can be less expensive than design analysis analysis of tolerances and tolerance buildup and costly quality control procedures and inspection With the X Ray Leakage Detection System you can perform a full scan of your product in only two minutes Leakage detection system configurations Ion chamber mounting ring and hardware High voltage cable 17 channel Rack Cabinet Control Module High voltage cable 3 channel 1 Calibration current source 1 1 Requires one per channel Requires two per channel t Specify 120 V ac or 22 V ac Module Description 17 channel system 3 channel system No req No req 96010A Ion Chamber w NIST traceable calibration 17 3 50300A Electrometer 17 3 10970 Mainframet 1 1 70010A Dual Channel Comparator 9 2 70020 Reference Control Module 1 1 55 foot interface cable 9 2 High voltage supply 1 1 1 1 1 Diagnostic X Ray Quality Assurance Instruments Key features e Ion Chamber arra
171. mon to most radiological procedures requiring fine ana tomical details The 76 606DX provides a consistent tool for researchers clinicians and technologists It is ideal for determining optimum system settings com missioning new equipment monitoring system performance and training in dental x ray panoramic x ray CT and cone B beam CT procedures AT Mvax The phantom includes an adjustable stand for positioning within a cone beam CT or pan oramic x ray system The jaw of the phantom is slightly opened and front teeth are vertically aligned to replicate correct posi tioning with a bite guide Please note that an actual bite guide can not be positioned in this product The phantom is constructed of proprietary tissue equiva lent materials ATOM MAX is made of tissue simulating resins that mimic the X ray attenuation properties of human tissue for both CT and therapy energy ranges 50 keV to 25 MeV The 76 606DX approximates the average male human head in both size and structure The phantom includes detailed 3D anthropo morphic anatomy including brain bone larynx trachea sinus nasal cavities and teeth The bones contain both cortical and trabecular separation The teeth include distinct dentine enamel and root structure including the nerve The sinus cavities are fully open Simple to set up and easy to use The 76 606DX stand allows accurate phantom positioning The included stand is adjust able in the x y z axes
172. more productive work schedules Imaging equipment can be evalu ated for axial and lateral resolution vertical and horizontal distance cali bration and linearity and ring down This updated and improved phantom is filled with Zerdine a solid elastic water based polymer that exhibits echogenic patterns similar to those encountered in human liver parenchyma Unlike other phantom materials Zerdine is elastic and is not damaged by heavier scan ning pressures It is also highly resistant to damage by extreme temperatures Specifications Phantom body Phantom material Zerdine solid elastic water based polymer Freezing point 0 C Melting point above 100 C Storage temperature Speed of sound O C to 66 C 32 F to 150 F 1540 m s 6 m s Attenuation coefficient 0 5 dB cm MHz or 0 7 dB cm MHz Scatter Mimics healthy liver parenchyma Positional tolerance of wires monofilaments Stated distance 0 1 mm Diameter of cylindrical targets Stated Diameter 5 Base material Cork Phantom dimensions WxHxT 20cm x 2 cm x 8 cm 7 87 in x 8 26 in x 3 15 in Weight 3 36 kg 7 4 lb Optional scanning trough For scanning with a liquid coupling agent water or coupling oil Optional carrying case This insulated case is large enough to hold the phantom and trough and also protects the phantom from extreme heat or cold Optional acoustic standoffs A fas
173. n excellent choice for measurements necessary in maintaining a diagnostic quality assurance program for several machines and modalities Diagnostic X Ray Quality Assurance Instruments Biomedical Key features e Digital auto ranging data display e Electrometer in probe handle e Digital signal transmitted over shielded cable for noise immunity e Automatically calibrated and adjusted for any 660 series probe e Available in SI units e Includes fitted carrying case e Exposure or exposure rate modes e Rechargeable batteries or ac power e Built in calibration auto ranging e Very portable Range Three decade auto ranging and auto indicating with proper decimal placement and measurement units See selected ion chambers specifications for specific ranges Calibration Unnecessary Response depends on frequency of internal crystal oscillator 0 01 from 10 C to 40 C Accuracy Depends only on crystal oscillator frequency in Exposure Rate mode See selected probe s specifications for measurement accuracy ee ee ee ee ee ee EEEN Controls Function switch selects off total exposure or exposure rate modes Reset switch selects run stop or reset in Total Exposure Mode Intensity knob controls readout brightness Error prevention logic Low battery auto turnoff OverRange indicator Excessive intensity indicator Probe disconnected indicator
174. nal accessories 07 AEC6 For film screen appli cations to assess and calibrate automatic exposure control AEC radiographic and mammo graphic systems 07 AEC6M For film screen applications to assess and cali brate automatic exposure control AEC mammographic systems Diagnostic X Ray Quality Assurance Instruments The O7 MAS5 mAs Meter simultaneously pro vide mAs exposure time and mA as well as mA waveform information This intelligent meter displays three 50 milliseconds mA waveform samples so radiographic and mammographic pre heat circuits can be analyzed and adjusted without using an oscilloscope Based on feed back from field service engineers the 07 MAS 5 also features a button that causes the meter to ignore the first 10 milliseconds of the mA wave form Featuring a microcontroller to analyze the digital mA waveform the O7 MAS5 mAs Meter accurately display the values essential for analyzing and calibrating radiographic and mammographic equipment The four line LCD displays the following Line 1 mAs average tube current mA times mA waveform C C exposure time Line 2 Exposure time mA waveform exposure time in seconds Line 3 mA average tube current mA over the entire mA waveform Line 4 Three sample mA waveform values lst waveform value represents the average mA for the Ist 50 milliseconds of exposure 2nd waveform value represents the average mA for the 2nd 50 milliseconds of
175. nfolded Step Block with Retaining Hasp removed l Weight 13 9 kg 30 7 1b Registration Plate My G o o o fe o fe fe fe fe fe oo 2920 0090 002020 9902020 002020 008080 000080 0020 0 050900 009090 009 01 020 2520 0595 2920 o o o o o o o e o o 0200 0200290 o o oo o 00 9 2020 206 o o 20 29 0090 080 020 020 o2 6 o o o o 02020200 o o o o o o o o o o 090 000909 020 o 29 o o0 o0 o9 o 05 oxo o o2 e o o e 0o90 o o o o o e o o o o o o o Radiography Fluoroscopy Phantoms and Accessories Optional accessories 76 705 Artery Block with 15 mg per ML venous concentration 76 705 1150 Artery Block from 76 700 1150 phantom with 150 mg per ML arterial concentration 716 705 1300 Artery Block from 76 700 1300 phantom with 300 mg per ML arterial concentration 76 711 Step Wedge 76 712 Slot Block 76 713 Bone Block 76 714 Blank Insert 76 715 Low Contrast Artery Insert 76 716 Low Contrast Iodine Line Pair Insert 76 717 High Contrast Resolution Pattern Insert does not include test pattern s 76 718 Registration Plate 76 719 Linearity Insert Optional high contrast resolution test patterns 07 527 High Precision Test Pattern 0 01 mm thick 07 538 1000 High Precision Test Pattern 0 1 mm thick 07 538 2000 Ultra High Precision Test Pattern 0 1 mm thick
176. nics Standards Association VESA standards and e A e i eae ae Selectable polarity settings for most fixed frequency monitor scan formats Additionally the horizontal and vertical sync 07 894 is field upgradeable to custom frequencies Four video outputs patterns full raster color bars gray scale and dotted cross hatch e Optional 10 minute timeout with 16 colors and intensity control provide all the patterns and on video to prevent CRT colors normally required to test and align any monitor burn in Use the 07 894 to cut repair time and reduce equipment e Four video patterns with 16 downtime Battery power enables you to repair monitors at the colors and intensity control job site eliminating the need to disconnect the monitor and povided transport it to another location for testing Projectors can be aligned onsite without the host workstation being present Color bars Gray scale Cross hatch Full raster Dimensions WxDxH 20 3 cm x 17 cm x 7 cm 8 in x 6 6 in x 2 7 in Patterns The four video patterns with 16 colors and intensity control provide all the patterns and colors normally required to test and align any monitor Power supply 9 V dc 500 mA wall transformer or six C cell alkaline batteries Compatibility Over 100 frequencies cover a wide range of monitors including all industry standard PC MAC and SUN frequencies Connectors VGA 15 pin HD female MAC II 15 pin D female SUN 13W3 D fem
177. nsharpness and phantom entrance dose Applications Test objects are positioned Figure 1 The NEMA Cardiology phantom at the center of the NEMA Cardiology Phantom This simulates the location of clinically important organs The NEMA Cardiology Phantom positioned with its center at the x ray sys tem s isocenter simulates clinical imaging geometry Therefore the geometric magnification of the test objects is similar to that of the clinical target The receptor blur focal spot penumbra blur and x ray scatter are also similar in test and clinical condi tions The entrance surface of a thick phantom is closer to the x ray tube than the entrance surface of a thin phantom This is an additional reason why patient phantom dose increases with phantom thickness e Visualized field size A plate is placed on the entrance surface of the image receptor The plate is fluorographed to determine the actual field of view FOV e Congruence of irradiated and visualized fields This test is not needed if the shutters are fully seen in the FOV under test CAUTION digitally synthesized shutters may simulate this effect without actual beam collimation e Spatial resolution A standard bar pattern insert is included in the central test plate The test plate is placed with the bars at 45 to the video lines or digital image matrix This produces the smallest change in the moir pattern resulting from a small change in angle See Figures 2 and 3
178. nt hardwiring Single electrical power exit location on the rear of fixture allows for surface mounted fixtures to be directly wired to the wall Diagnostic viewing center Angled mounting top tier vertical and bottom tier angled at 20 maintaining centralized Cluster Switching angulation and corner located at bottom center of fixture which controls top and bottom tiers see DVC information mounting Light source and luminance Techline Series Illumination Amps ALET Fluorescent levels expected per panel requirements lamp type minimum cd m Techline 200 series Standard 2000 0 75 118 V 60 Hz 2 F15IT8 D per panel Techline 300 series Standard high intensity 3500 0 66 118 V 60 Hz 3 F15T8 D per panel Optional dual intensity 2500 low mode Optional dual intensity 3500 high mode Techline 400 series Standard high intensity 4000 0 7 118 V 60 Hz 4 F15T8 D per panel Optional dual intensity 2000 low mode Optional dual intensity 3800 high mode The noted series exceeds the American College of Radiology recommended light level of 3000 cd m for mammography viewing Published readings are 3 less than actual test levels to allow for decreased light output as a result of normal usage These light levels are taken from procedures specified by the German DIN 6856 standard Currently this is the only published standard for evaluating the luminance levels of x ray illuminators These lev
179. onal accessories 716 025 4000 Aluminum Step Wedge CDRH Dental Image Quality Test Tool 76 025 set up for half value layer measurements BACKGROUND DENSITY AREA LOW CONTRAST OBJECTS EMBEDDED HUMAN TOOTH FOR FILM Diagram of Aluminum Step Wedge used for darkroom CDRH Dental Image Quality Test Tool 76 025 set up fog and consistency testing for dental exposure measurement protocols Materials Base Wood Test tool Acrylic Step wedge Type 1100 aluminum Dimensions WxDxH Base 10 cm x 20 cm x 4 9 cm 3 94 in x 7 87 in x 1 93 in Test tool 7 6 cm x 5 5 cm long 3 cm x 2 17 cm Step wedge 5 1 cm x 12 7 cm x 1 3 cm Weight 0 88 kg 2 06 1b Radiography Fluoroscopy Phantoms and Accessories 76 606DX The 76 606DX ATOM MAX Diagnostic Head Phantom is a standard of reference for diagnostic radiology of the head The phantom is designed Biomedical Key features e Our most realistic maxillofa cial phantom for dental cone beam CT and panoramic x ray e Includes detailed anatomical features e Frankfurt plane identified to ensure proper alignment e Tissue equivalent from 50 keV to 25 MeV e Positioning stand with six degrees of freedom e Carrying case included e Four year warranty to assist technical and clin ical staff in the selection monitoring training and verifi cation of scanning parameters com
180. ondition b need to adjust exposure factors Output signal BNC connector for waveform analysis Dimensions WxDxH 20cm x 15 cm x 6 cm 8 in x 6 in x 2 5 in Weight 0 9 kg 2 lb 36 Diagnostic X Ray Quality Assurance Instruments Biomedical Key features e Choose from three kVp meters e Easy to read digital display e Fast and easy setup e Automatic display reset e No remote control cables e Scope output for waveform analysis e Compact lightweight and battery operated Optional accessories 89 473 Carrying Case 18 526 Series Service and Quality Control Kits 18 526 3000 Cardiac Cath Special Procedures QC Kit Contains the essential non invasive test tools for special procedures 18 526 1000 Mammography QC Kit Everything you need to make compliance with ACR and MQSA regulations easy 18 526 2000 Radiography Fluoroscopy QC Kit All the test devices necessary to perform QC in radiographic and fluoroscopic suites 18 526 4000 Dental QC Kit Service and QC are easier and more cost effective than ever with this comprehensive kit rs Diagnostic X Ray Quality Assurance Instruments FLUKE o Biomedical Key features e Each kit contains the essen tial instruments that service personnel physicists and QC technicians rely on to check and calibrate today s most vital equipment Every instrument selected for inclusion in our Service QC kits was selected for reliabil ity
181. or 0 7 dB cm MHz scanning trough carry ing case and the AIUM Quality Assurance Manual 124 The 84 340 General Purpose Multi tissue Ultrasound Phantom is constructed from a patented solid elastic material called Zerdine Unlike other phantom materials it is not affected by changes in temperature It can be subjected to boiling or freezing conditions without sustaining significant damage It is also more elastic than other materials and allows more pressure to be applied to the scanning surface without subse quent damage to the material At normal room temperature Zerdine will accurately simu late the ultrasound characteristics found in human liver tissue It contains dense and cystic masses in a range of sizes one high density target and an assortment of nylon monofilament target groups It was designed to allow for assessment of linearity axial and lateral resolution depth calibration dead zone measurement and registration within two different backgrounds of 0 5 dB cm MHz and 0 7 dB cm MHz The phantom is protected by an acrylic case and plastic membrane to facilitate scanning and minimize desiccation Biomedical Key features e Complies with the AIUM Stan dard for Quality Assurance e Simulates characteristics found in human liver tissue e Ensures patient s safety and doctor s confidence e Perfect for QC service use since phantom is not affected by changes in tempe
182. ostic X Ray Quality Assurance Instruments Key features 07 661 7662 e Verifies proper alignment of collimator light field to x ray field e Verifies alignment of central ray is perpendicular to image receptor 07 644 e Checks focused grid alignment with relation to central ray e Checks focused grid align ment to the center of a film cassette 07 644 Grid Alignment Test Tool Increased patient radiation dose and reduced image con trast can result from lateral decentering or tilting of a focused grid used in a Bucky apparatus The 07 644 Grid Alignment Test Tool is used to check whether a focused grid is aligned properly with the central ray and the center of the film cassette The easy to use test tool is centered on the x ray table and fixed in position perpen dicular to the grid lines Five exposures are made with the x ray beam sequentially cen tered on each of five holes and the optical densities of the hole images are com pared A properly centered and leveled grid will result in equal density changes in the hole images on either side of the central hole Unequal density changes indicate the need for correc tive action Biomedical The 07 591 Focal Spot Test i Tool provides a simple pass Optional accessories fail test to determine if an 07 800 5007 Flex Film Cassette 5inx7in x ray tube focal spot has been damaged This tool consists of a 6 inch high stand with a thirteen
183. ound plug No hazardous electrical parts are exposed when the diffusing panel is removed for cleaning or lamp replacement eee eS F E ai qp im Ls ior ihrer r i IF ar HF at 3r m iw ur r TAi Erpe p 17 Temy LE eg i reei eek hea HEr a EA i fier Film Handling and Storage Biomedical 77 201VR to 77 266VS Surface mounted Dimensions inches Model Model with FAS Shipping Viewing area Length Height option wot Ib 1 panel 14 in x 17 in 14x 17 14 21 77 201VS 77 201 VS FAS 17 2 panel side by side 28 x 17 28 21 77 202VS 71 202VS FAS 33 3 panel side by side 42x 17 42 21 77 203VS 71 203VS FAS 50 4 panel side by side 56 x 17 56 21 77 204VS 71 204VS FAS 67 5 panel side by side 70x 17 70 21 77 205VS 71 205VS FAS 84 6 panel side by side 84x 17 84 21 7T1 206VS 77 206VS FAS 101 1 over 1 14in x 17 in 2x 14x17 14 42 T1 211VS 77 211VS FAS 33 2 over 2 2X28 x 17 28 42 77 222VS 7T1 222VS FAS 67 3 over 3 2xX42x 17 42 42 77 233VS 71 233VS FAS 101 4 over 4 2x56 x 17 56 42 77 244VS 71 244VS FAS 134 5 over 5 2x70x 17 70 42 77 255VS 71 255VS FAS 278 crated 6 over 6 2x 84x 17 84 42 77 266VS 71 266VS FAS 346 crated Viewing height is actually 16 5 inches in order that extraneous light is eliminated when standard 14 in x 17 in film is inserted Pilm Activated Switches FAS options Recess mounted
184. p ci 4 Ordering information ACC A ECHO ER Le aee Group 2 i i ie 17 18 19 21 Pattern LP mm 2 9 3 5 4 2 5 6 7 8 5 10 8 5 Z 6 Diagnostic X Ray Quality Assurance Instruments 07 503 to 07 551 07 456 Star Patterns High Purity Aluminum Step Wedges Shown in 07 509 2000 Shown in 07 509 2000 Star x ray test patterns Focal spot size can be determined by observing the regions of blurring which occur when the pattern is radiographed by an x ray source of finite dimensions Radiation from different areas of the focal spot will cause a periodic blurring of the pattern due to penumbra effects Knowledge of the geometric factors and the distance from the center of the pattern to the region where blur ring occurs will permit the calculation of the focal spot size with the same accuracy as measurements made with a pinhole camera Specifications 07 503 2000 Dimension 55 mm 07 503 1000 For measuring focal spots from 0 1 mm to 0 3 mm 07 550 Sectors 4 15 patterned sectors with a 0 5 angle of a single line within a sector 07 551 Sectors 07 550 4 45 patterned sectors for easier interpretation Sectors 07 551 4 15 patterned sectors with a 0 25 angle Thickness Lead foil thickness 0 03 mm 07 509 2000 Dimension 55 mm 07 509 1000 For measuring focal spots from 1 mm and up Sectors 4 45 sectors with a 2 angle of a single line within a sector Thickness Lead foil thickness 0 05 mm 07 5
185. pecifications provide guidelines for quality Provides a means of repro ducible setup ensuring a consistent test protocol e Reduces the need for repeat films e Reduces setup time e Increases patient safety e Minimizes chance of control procedures for diagnostic dental radiography In order to perform these procedures a suit able phantom was developed the 07 625 CDRH Dental Image Quality Test Tool The JCAHO requires certain misdiagnosis standards to be met regarding e Ideal for dental service radiographic quality control The engineers and inspectors 07 625 CDRH Dental Image Quality Test Tool facilitates compli ance with these standards since the standards were compiled using a prototype of this phantom The 07 625 CDRH Dental Image Quality Test Tool is designed specifically for testing the functionality of dental x ray units and provides a means of evaluating half value layer determining kVp and assessing overall image quality It is the only dental test tool designed with dental service personnel and inspec tors in mind The test tool will significantly improve the ability of service personnel to quickly and accurately survey the image quality of the x ray unit The 76 025 CDRH Dental Image Quality Test Tool can also be used as a constancy check for x ray film processing making it the most versatile and cost effective dental test tool available today Clinical imaging involves diagnosis of tooth pathology In o
186. r and over table fluoroscopic tubes e Compact and easy to use 4 6 mm Al 1100 Alloy The Conference of Radiation Control Program Directors CRCPD the professional organization of state and local radiation control agencies along with the Food and Drug Ad ministration FDA of the federal gov ernment conducts the Nationwide Evaluation of X Ray Trends NEXT survey program can be improved Optional accessories 07 649 1169 Fluoroscopic Image Quality Test Object This patient equivalent phantom of uniform thickness consists of a 7 inch thick acrylic block one Fluoroscopic Image Quality Test Object one lead stop plate and one copper attenuation plate Base 2 type 1100 aluminum plates each 2 3 mm thick 4 lead beads embedded on top to be used as collimation orientation points This 3 2 mm 0 125 in plate simulates maximum attenuation and can be used to measure the maximum air kerma rate free in air This 1 6 mm 0 06 in copper filter simulates the presence of a 2 mm thick layer of barium sulfate and can be used to measure the air kerma rate free in air This is comprised of eight low contrast test holes each 0 375 in and ranging in depth from 0 0063 in to 0 068 in and eight wire meshes ranging from 12 to 60 lines per inch The test object is used for the assessment of spatial resolution and can easily be taken on and off the phantom 17 8 cm x 17 8 cm x 19 3 cm 7 inx 7 in x 8 in
187. r use with all possible positions Weight is 0 78 kg 1 75 1b Included accessories Suction cup Each set includes a holder the small set gets a small holder the larger sets get a larger holder Ordering information 18 210 8000 Standard Kit of 8 View Markers 18 210 1400 Specialty Kit of 14 View Markers 18 210 2200 Full Service Kit of 22 View Markers Watertank Material 776 410 4130 The increasing use of computed tomography CT as a diagnostic tool creates the need for an efficient means of evaluating the performance of the CT scan ners now in use Recognizing this requirement the American Association of Physicists in Medicine established the AAPM Task Force on CT Scanner Ang Phantoms Its goals are to define CT scanner performance and present practical methods of performance testing through the utilization of special phan toms This phantom design is based on the guidelines presented in Report 1 of the Task Force and approved by the AAPM The modular 76 410 4130 AAPM CT Performance Phantom offers the CT user a single system with which to measure nine performance parameters This phantom permits the routine standardization of alignment beam width spatial uniformity linearity contrast spatial resolution linespread noise size inde pendence and absorbed dose All components of the phantom are housed in a compact transparent tank that holds the system together in the correct orientation The phantom
188. range indicator above 160 mAs Also O mAs to 1999 mAs overrange indicator above 1600 mAs Accuracy 2 of reading Input 25 mA to 1000 mA Drift Zero Operating temperature 15 C to 30 C 50 F to 100 F Controls POWER on off RANGE highlow and RESET Power requirements Single 9 V alkaline battery typical life 80 hours Input jack Uses two banana jacks Dimensions WxDxH 8 9 cm x 16 8 cm x 3 5 cm 3 50 in x 6 63 in x 1 38 in Weight 0 2 kg 0 44 Ib Diagnostic X Ray Quality Assurance Instruments Key features e Accurately measure x ray generator mAs values e Meets today s QC needs for accuracy and dependability e Used for calibration of high current and phototimer accuracy e Calibrated directly in mAs no calculations required e Handheld battery operated and lightweight Biomedical Biomedical Key features e Replacement for GE divider e Can be used with oscilloscopes or dc digital voltmeters e Three individually wired anode connectors for use with the latest GE CT scanners 07 469 Wave Precision High Voltage Divider provides two ranges that allows it to be used with a variety of readout devices One range of 07 469 is 10 000 1 when operated into a 1 MQ load such as the direct input of an oscilloscope The other mode of operation provides the 1000 1 ratio into a 10 MQ load In this mode it can be used as a replacement for the GE divider when con nected in a s
189. rate easy to use versatile and truly portable Specifications Pinhole diaphragm dimensions mm D L 0 020 0 010 Nominal pinhole diameter mm 07 613 0 030 0 005 0 075 0 010 0 030 07 617 0 075 0 005 0 350 0 010 0 075 0 500 0 010 Custom pinholes available on request 07 620 Weight 10 08 kg 0 0518 07 635 Weight 040 kg 0 20 Diagnostic X Ray Quality Assurance Instruments FLUKE o Biomedical i a a 07 611 Pinhole assemblies Ordering information 07 633 X Ray Pinhole Assembly 07 613 X Ray Pinhole Assembly 07 617 X Ray Pinhole Assembly 07 611 X Ray Pinhole Assembly 07 620 Comparator 7X Magnification 07 635 Comparator 25X Magnification 57 4 Series CLEAR Pb Compensation Filters F Lightweight CLEAR Pb lead plastic filter is fully transparent Single exposure AP view of the foot radiograph at left wastaken without a CLEAR Pb filter Notice burnout at the toesdue to increased technique needed to properly expose the dense tarsal bones The radiograph on the right was taken with a CLEAR Pb filter The image density is uniform from instep to toes Radiography Fluoroscopy Phantoms and Accessories CLEAR Pb Compensation Filters eliminate the problems inherent in imaging a wide range of densities on one radiograph Because they are far superior they replace the bulky heavy aluminum
190. rature e Promotes uniform system performance for all types of imaging equipment including small parts scanners e Supplied with insulated rugged storage carrying case e Quick scanning can be performed without removing phantom from the airtight case Tolerances Distance between any two wires equals stated 0 38 mm Material Zerdine Type Solid elastic water based polymer Freezing point O C Melting point Above 100 C Cylinder diameters equal state 5 Accuracy of measured parameters Attenuation coefficient 0 5 dB cm MHz 0 7 dB cm MHz Speed of sound equals stated 3m s Speed of sound 1540 m s Scanning well 1 cm deep Scanning membrane Saran Attenuation coefficient equals stated 0 02 dB cm MHz Targets Material Monofilament nylon wire Diameter 0 1 mm Temperature at time of measurement Vertical and horizontal plane target Number of groups 1 Number of targets 7 Depth range 9 cm Spacing 2 cm Recorded on certification document Resolution targets Number of arrays 3 Depths 3 cm and 10 cm Axial intervals 0 5mm 1mm 2 mm 3 mm 4 mm and 5 mm Horizontal intervals 1 mm 2 mm 3 mm 4 mm and 5 mm Low contrast targets Number of targets 4 Diameter of targets 2 mm 4 mm 6 mm and 8 mm Depth of targets 2 cm 4 cm 6 cm and 8 cm Contrast of targets 15 dB relative to background High contrast targets Number of
191. rder to permit an accurate simulated clinical image evalua tion the test tool contains a human tooth encased in its center The 76 025 CDRH Dental Image Quality Test Tool consists of a wooden cradle to hold the test tool body built in slots for attenuation filters a film slot an exposure chamber holder and a mounting screw for use with a tripod The test tool comes with an aluminum step wedge that is designed for evaluating darkroom fog and consistency testing The step wedge has two slots one for exposing a film pack and one for evaluating dark room fog The film slot also ensures easy reproducible placement of the film for consistent imaging To use the 76 025 CDRH Dental Image Quality Test Tool it is necessary to establish an acceptable baseline or standard for the x ray unit performance The test tool should be imaged using the same technical factors that were used to establish the baseline These images when compared to the baseline will allow the user to determine if image quality degradation is occurring so appropriate corrective action can be taken NEXT Nationwide Evaluation of X Ray Trends is a committee of the Conference of Radiation Con trol Program Directors CRCPD that oversees quality control procedures for diagnostic radiology They issue procedure protocols and guidelines for imaging modalities Radiography Fluoroscopy Phantoms and Accessories Biomedical HIGH CONTRAST OBJECTS WIRE MESH Opti
192. re is made at which time the reading is automatically updated Automatic display indicators tell you when adjustment of exposure factors or battery replacement is necessary Neither remote control cables nor time consuming manual re zeroing are needed A BNC connector is provided for radiation waveform display on a storage oscilloscope Ranges Wide range Low 50 kVp to 90 kVp 0 1 kVp resolution High 80 kVp to 150 kVp 0 1 kVp resolution Mammographic 24 kVp to 40 kVp 0 1 kVp resolution Dental 45 kVp to 90 kVp 0 1 kVp resolution Accuracy Wide range 3 or 3 kVp whichever is greater Mammographic 3 or 1 5 kVp whichever is greater Dental 3 or 3 kVp whichever is greater mAs requirements Wide range 45 7 cm SDD 18 mAs at 120 kVp 50 mAs at 60 kVp single phase Minimum exposure time 1 20 0 05 sec Mammographic 25 cm SDD 100 mAs at 24 kVp Minimum exposure time 1 20 0 05 sec Dental 8 5 mAs at 45 kVp 0 026 mAs at 90 kVp Controls Wide range On off single three phase and range selection switch Mammographic On off and Moly Tungsten selector switches Dental On off and single three phase selector switches Operating temperature 10 C to 40 C 50 F to 104 F Relative humidity O to 90 non condensing Power requirements 9 V alkaline battery 150 hours operation Display 3 5 in x 0 5 in LCD Automatic indication of a low battery c
193. reathe dust or vaai The bottle of test chemical makes 100 ml of Monge Wash theoreti i solution enough to provide dozens of tests HYPO ESTIMATOR 4 NUCLEAR A Sbm Goad WY anata Weight of kit 0 12 kg 0 25 lb Film Handling and Storage The 18 220 Mammographic Accreditation Phantom will assist you in complying with MQSA and the American College of Radiology ACR Quality Control Programs This phantom is intended for use as an integral part of the Mammographic Quality Control Program and when used to perform routine mammographic QC it will help you quickly easily and accurately evaluate the overall imaging perfor mance of your mammographic system This phantom will detect imaging changes so you can make the necessary cor rections in order to maintain your system at peak performance The 18 220 Mammographic Accreditation Phantom was designed to test the performance of a mammographic system by a quantitative evaluation of the system s ability to image small structures similar to those found clinically Objects within the phantom simulate calcifications fibrous calcifications in ducts and tumor masses The phantom is also designed to determine if a mammo graphic system can detect small structures that are important in the early detection of breast cancer Test objects within the phantom range in size from those that should be visible on any system to objects that will be dif
194. resolution automatic exposure control AEC function and half value layer HVL to meet regulatory requirements Custom carrying and storage case with sturdy wheels and extendable pull handle allows users to easily transport components from site to site Included accessories 07 600QC Al plate 1 mm x 100 mm Two Al plates 2 mm x 100 mm Two Cu plates 1 mm x 200 mm Pb assembly 2 mm x 300 mm between two pieces of 2 mm PMMA Four PMMA plates 50 mm x 300 mm with four polyethylene spacers Leeds TOR 18FG phantom Leeds TOR Cu plate 07 661 7662 Three piece Collimator Alignment Tool 07 533 Radiopaque Ruler 007 523 2000 Test Pattern 07 620 Magnifier Metric Tape Measure 3 m 07 600QCN All components from the 07 600QC kit plus 37596 8000 NERO mAx stand base 37589 Stand Vertical Rod 37586 HVL Holder One stand for external ion chamber Ordering information 07 600QC Quality Control Kit 07 600QCN Quality Control Kit for Fluke Biomedical 8000 NERO mAx system The 07 680 NEMA Cardiology Phantom was designed by collaboration with SCA amp I to provide a cardiovascular fluo roscopy benchmark phantom It is used to test systems under conditions simulating normal clinical use for fluoroscop ically guided invasive and interventional procedures The phantom test ensemble includes tests for imaging field geometry spatial resolution low contrast iodine detect ability working thickness range motion u
195. roducibility Beam quality Breast entrance exposure AEC reproducibility Average glandular dose and Radiation output rate NERO mAx fluoroscopic template Used to perform the following fluoroscopic tests kVp accuracy Beam quality and Fluoro exposure rate These templates are easy to use and can be modified to fit the user s needs Diagnostic X Ray Quality Assurance Instruments Biomedical System requirements Windows 2000 and above Microsoft Excel 97 2000 One serial port COM1 through COM4 The Crescent X Ray Leakage Detection System is custom E designed for accurate low level T radiation measurements 7 4 When used in a suitable configuration the system demonstrates compliance to Title 21 CFR subchapter J Part 1020 30 k of the Radiation Control Act The 10970 Crescent X Ray Leakage Detection System consists of a combination of Ion Chamber Electrometer Modules 96010A 50300A and a Control Console will include 70010A Dual Channel Comparator Modules 70020 Reference Control Modules and power me supply The air filled ion chamber electrometer module is the j basic component of the system Seventeen of these modules are sufficient to provide a full spherical scan and are connected to the control console through low impedance cable for remote monitoring The Control Console contains the high voltage ioniza tion potential a precision comparator and trip circuits reference
196. roscopy Phantoms and Accessories Biomedical O7 101 2000 Key features e Eliminate the tedious and time consuming calculations you are now doing to comply am ie ay palle with patient safety needs e RADCOMP software will generate the required table of patient entrance skin expo sures quickly conveniently and accurately Em E e RADCOMP is so accurate Ll i that its output was adopted ee et L by NCRP 102 senke e aa e RADCOMP s simplicity lends itself to use by anyone Vere epephe bee Ar Enpoire Ae Teck chai f although a qualified physicist Ge i n a oii must review the results for Paid bp oe eet de ont or JCAHO compliance er The 07 101 2000 RADCOMP can be used for x ray fluoroscopy mammography and cardiac cath The user inputs typical projec tions used for each procedure aluminum filtration kVp mAs etc and the RADCOMP program will make all the calculations quickly and accurately In addition RADCOMP can tabulate technique charts RADCOMP generates a unique scale factor for each individual x ray tube It is derived by making only three or four exposure measurements at different kVp settings RADCOMP automatically matches these measurements against reference data This refer ence data was obtained under controlled conditions and does not require user input The scale factor is used by RADCOMP together with simple user input kVp mAs and focus to skin
197. rovided for QA tests on radiographic fluoro scopic and mammographic x ray machines Templates may be modified Taahealagiveel to perform user specific tests 7 Temni and generate customized ee a car s Date eae ma ee marl ethene kisii e Allows complete remote Era g mack al iP it control of the 4000M NERO i Paley 1 Bemp gerd at pee Trike e Complete online help speeds learning SEES e Compatible with Microsoft f laren tuehooes a Windowse 2000 and above j I F 7 and Excel 95 97 2000 e e Automatically detects the PF presence of 4000M NERO F a1 3 1 Mammographie Unit Assembhy Evaluation aL a Te dasha Coleen Pomme JBT j lieder fiestas epis j bom Sei J Times j ree Peli jaj bpr Me The 4000 Toolkit for Excel is a complete software package for the 4000M NERO that includes an Excel Add In called 4000 Add In and Excel templates that may be used to evaluate the performance of radiographic mammographic and fluoroscopic x ray machines The 4000 Add In collects measured results from the 4000M NERO and places the data in the cells of the active Excel worksheet starting at the active worksheet cell The 4000 Add In also may be used to acquire and graph radiation and kV waveforms from the 4000M NERO as well as remotely control the 4000M NERO ream ree a Tarei pes a aA Sheed bree dd bs raed ae a SE DL feo rn emery ome e een no en one ee ee ee ee Diagnostic X Ray Quality Assurance Inst
198. ruments 26 Controls Telele 4E The 4000 menu provides an interface for the user to remotely control the 4000M NERO and retrieve radiation and kV waveforms A description of each menu option follows Remote control Selects the 4000M NERO measurement mode and measurement options This allows the user to select the correct measurement mode for the template in use For instance the radio mode is selected when using the radiographic template the Mo Mo target filter is selected when using the mammographic template and the fluoro mode is selected when using the fluoroscopic template Retrieve rad waveform Retrieves the radiation waveform data from the 4000M NERO and charts it in a new Excel chart Retrieve kV waveform Retrieves the kV waveform data from the 4000M NERO and charts it in a new Excel chart Templates Three templates are also provided with the 4000 Toolkit for Excel a radiographic template a mammographic template and a fluoroscopic template Each template includes a help worksheet with detailed instructions for its use 4000 radiographic template 4000 mammographic template Used to perform the following radiographic tests Reproducibility kVp accuracy Timer accuracy Linearity and Beam quality used to perform mammography tests required for ACR and MQSA Measured data from the Model 4000M NERO may be automatically collected in the following worksheets kVp accuracy kVp rep
199. ry The disc section is attached to a rectan gular acrylic bar containing a thin copper wire embedded along a central groove This section of the phantom is used to evaluate laser beam alignment and accuracy of slice thickness slice spacing slice contiguity and pilot scan to transverse longitudinal scan correspondence This is achieved by exposing a non screen film such as Flex Film Cassettes listed below placed underneath the phantom and making several cuts while the phantom is advanced along the gantry in a pre programmed manner Dimensions 6 inch 1 in thick with six 1 125 in through holes and four 0 5 in through holes Lucite disk The Lucite disk is attached to the side of the base by two removable nylon slotted screws Inserts Phantom is supplied with seven inserts for 1 125 in holes 1 each of Plastic Waterse bone equivalent polystyrene polycarbonate polyethylene nylon and one acrylic high contrast resolution insert Lucite base LxWxT 11 94 in x 1 81 in x 0 69 in with copper wire approx 0 02 in fixed into a 0 02 in deep groove centered on the base Weight 1 36 kg 3 1b CT Quality Assurance Key features e Lightweight compact and extremely portable e Ideal for field service use e Used with any CT scanner for measurement and analysis of all major CT scanner functions and radiation dose e Makes inhomogeneity correc tions in radiation oncology Accurately ev
200. s in Medicine AAPM Digital The U block provides a very Radiology Fluorography Task Group of the Diagnostic X Ray sturayisupporiumnenentrance Imaging Committee exposures are being measured D ee inih li fth b di with a dosimeter ion chamber ramatic improvement in the quality of the subtracted image Two artery blocks in two due to improved phantom stability and increased homogeneity of concentrations of iodine bone material in bone blocks 15 mg ml and 150 mg ml for This phantom eliminates occurrence of mis registration increased clinical relevance artifacts caused by inadvertent movement of the phantom compo A 300 mg ml iodine artery nents during image acquisition block is available as an option Designed by Joel E Gray Ph D Professor Emeritus Mayo Graduate School of Medicine and Jerome P Taubel R T Department of Diagnostic Radiology Mayo Clinic and Foundation Manufactured under licensing agreement with Mayo Foundation for Medical Education and Research t This phantom conforms to the recommendation in Report 15 by the American Association of Physicists in Medicine AAPM Digital Radiography Fluoroscopy Task Group of the Diagnostic X Ray Imaging Committee Radiography Fluoroscopy Phantoms and Accessories Possible DSA phantom configurations Bone Block Slot Block for use with Slot Block Inserts TEE Folded Step Block with ee a Retaining Hasp eae ee phantom when using with dosimeter probe F U
201. s in contrast between adjacent targets With the 07 645 Fluoro Test target plates the user focuses on a subset of three targets at a given time In each subset or column large differences approx 3 are present between adjacent targets and it is easy to decide if a target is visualized or not The threshold contrast for a plate is the lowest of the values observed for the three columns of targets and a contrast resolution precision of 0 5 is obtained by the sequential use of the two plates When imaged at 80 kVp with 2 mm of Cu beam attenuation the targets of Plate A range in contrast from 1 to 8 in 1 increments Likewise the targets of Plate B range from 0 5 to 7 5 Tables of target contrast versus kVp permit the user to determine target contrast and therefore threshold contrast resolution at other fluoroscopic tube potentials Dimensions WxDxH Two 6 in x 6 in x 0 25 in 6 1 mm thick aluminum plates with each plate containing an array of 1 1 cm targets of varying contrast Three 6 in x 6 inx 1 mm thick copper attenuator sheets Weight 1 42 kg 3 15 lb Manufactured under licensing agreement with UAB Research Foundation University of Alabama at Birmingham Alabama The development of the 07 645 is based on the work of A J Wagner G T Barnes and X Wu Assessing Fluoroscopic Contrast Resolution A Practical and Quantitative Test Tool Medical Physics 18 1991 894 899 Radiography Fluo
202. specifications as 07 501 2000 07 521 2 0 to 10 0 15 0 05 94 x 50 07 525 3 15 to 16 6 15 0 03 94 x 50 07 555 5 0 to 20 0 13 0 02 25 x 10 07 515 1 0 to 10 0 1 0 05 80 x 40 07 523 2000 0 5 to 5 0 1 0 1 157 x 50 07 523 1000 Ultra High Precision Pattern same specifications as 07 523 2000 07 539 1 5 to 20 0 1 0 025 60 x 30 07 526 0 6 to 10 0 26 0 05 65x 55 07 527 0 6 to 5 0 20 0 01 50 x 50 07 535 0 6 to 5 0 20 0 05 50 x 50 07 538 2000 0 6 to 5 0 20 0 1 50 x 50 07 538 1000 Ultra High Precision Pattern same specifications as O7 538 2000 07 541 2000 0 6 to 3 4 2x15 0 1 50 x 50 07 541 1000 Ultra High Precision Pattern same specifications as 07 541 2000 anes 07 548 2 0t06 0 2x14 0 08 50 x 50 X Ray Test Patterns for measuring resolution of image intensifiers and video systems 2E 07 506 1 0 to 2 0 2x6 Ol 32 07 507 3 0 to 4 0 2x6 0 1 32 07 511 2 0 to 3 0 2x6 0 1 32 07 519 1 8 to 3 15 2x6 0 1 32 Shown in Model 07 506 07 529 2 8 to 5 0 2x6 0 1 32 07 532 5 0 to 6 0 2x6 0 05 32 07 537 5 0 to 7 0 2x6 0 05 32 07 526 0 6 to 10 0 26 0 05 65x55 Ultra High Precision Test Pattern for measuring modulation transfer function The Ultra High Precision Test Pattern utilizes 22 groups of line pairs Each group is indicated by the extended line above the pattern The resolution of the individual groups can be taken from the table Lead thickness is 0 05 mm Pattern size is 71 mm x 44 mm Shown in Model 07 553 Grou
203. spital Grade Plug T1 STARTER Starter 71 HW Surface Mount Hard 71 HGP REPL Hospital Grade Plug Wired 71 DP REPL Diffusion Panel per panel Lied Handle and Non Skid ee 77 LC REPL Re mount retrofit kits 71 REC SUR Recess to Surface per panel 71 SUR REC Surface to Recess per panel Line Cord and Plug Assembly 90 Film Handling and Storage Biomedical 186 231 2350 Key features e Helps ensure the image qual ity of stored radiographs e Determines the amount of Too much residual fixer in processed film will residual fixer in processed film have a degrading effect on the x ray image e Helps eliminate degradation Over a period of time the radiograph will start of image stability to turn brown and deteriorate rendering it use e Allows you to take immediate less to the physician corrective action The 18 231 2350 Fixer Retention Test Kit allows you to routinely monitor your film pro cessor s washing capabilities By applying the kit s solution to a test film and comparing the resulting stain to the comparison strip you FIXER RETENTS can quickly determine if insufficient washing Residual Hye has left a large amount of residual fixer on the a film This simple chemical test will show you or Medal whether the film is stable or whether corrective Sinn NITRATE AND DASAL action is needed to protect the long life of your Ths ar and emi az diograph gt SM Come FoR TED re Ami b
204. st cost effective and biopsy systems economical phantom for Because the phantom closely mimics properties of the human teaching training and QC breast it is also an ideal teaching tool and practice medium for mammographic needle biopsy procedures It should also be used whenever a new system is installed or repaired to ensure accu rate needle placement This training phantom is also an excellent research and devel opment demonstration tool for manufacturers of mammography equipment The phantom should be stored in a cool place The phantom should be discarded after all the tumors have been aspirated Specifications 18 228 Targets Color Dimensions Quantity Position Cystic masses green 5mm to 12 mm 6 Random a Dense masses black 5mm to 12 mm 6 Random ee Microcalcifications orange 0 3 mm to two clusters Mid plane 0 35 mm on right and left sides r Dimensions LxH 10 cm x 5 cm 1500 cc Weight 0 91 kg 2 Ib 18 228 Mammo Cube Stereotactic 18 229 1313 Mammo Cube Stereotactic Core Biopsy Phantom Core Biopsy Phantom Embedded lesions Six dense masses 5 to 12 mm Proprietary gel Simulates the physical density and mass attenuation of BR 12 The gel will not dry out after initial needle punctures thus extending storage life Physical consistency Similar to human tissue and combined with an elastic skin like Ordering information membrane which enables palpation of embedded stru
205. sy to read screen No more time spent calculating scope traces to derive kVp values Full medical oscilloscope scope functionality with color display ScopeMeter triggers on standard interlaced and high resolution non interlaced video systems Triggers on all lines nonselectively or select an individual video line up to 2800 lines per frame mAs measurement calculates current over time Smart averaging capabilities Extended vertical offset Selectable persistence mode Extended video triggering FlukeView for Windows for documenting enhanc ing waveform analysis and archiving results Biomedical 35080M 199XRAY rh 35080M Range 50 kVp to 150 kVp using only the wide range radiographic filter pack 37617 Range and versatility are extended with the use of special optional filter packs Accuracy 2 of reading in the range of 50 kVp to 150 kVp exclusive of linearity filtration and gain effects Linearity corrections automatically applied when using 35080M with either 35050AT Dosimeter or 199XRAY Response time 150 ps 10 to 90 Calibration Internally generated signal provides a calibration check Minimum time for valid reading 1 ms three phase one line cycle single phase Tube current Wide dynamic range from 4 mA to 3000 mA three phase 2 mA to 1500 mA single phase Generator settings will vary in waveform and distance Less than 1 kVp effect for wide r
206. t Its small lightweight design enhances portability and 100 wireless operation ensures setup can be accomplished in seconds Because the TNT 12000 measures all parameters with every exposure there is no need for complicated menu selec tion further enhancing user productivity TNT 12000 always defaults to the last use when powered on so when used often for repetitive procedures it is truly a one button power on solu tion The TNT 12000 has the expanded functionality needed for modern applications and can be managed with minimum keystrokes Users can identify and select custom measurement protocols and save them for future use Full test automation and documentation software is available for TNT 12000 creating the advantage of accurate repeatable testing processes Ansur Test Automation Software is only available from Fluke Biomedical Primary end benefit Productivity and accuracy are central goals when performing any maintenance or QA process on diagnostic imaging equipment because image system uptime is critical to patient care objectives TNT 12000 is small portable and wireless It is easily trans ported to the imaging room set up in seconds and all results Diagnostic X Ray Quality Assurance Instruments Biomedical Key features e 100 ZigBee wireless opera tion between detector and hand held display or laptop e Compact hand held design for maximum portability and ease of use Simple user interface with minimu
207. t capability 71 DVC11C 1 over 1 Angulated Corner System 71 DVCOO 1 over 1 Vertical Corner System available in one and two panel configura tions only Biomedical 77 201TR to 77 406TS Diagnostic Viewing Center DVC The features and benefits of the Techline can be combined with Maxant s family of Diagnostic Viewing Center angled and corner mounting systems for maximum viewing flexibility The DVC angulation system R _ creates a two tier fixture with a vertical top tier and a bottom tier angled at 20 A Techline High Intensity Hot Lamp illuminator housed in a DVC e For bright spot hot light film angulations system maintains all of the standard features associ illuminator ated with the Techline including centralized cluster switching e Variable rheostat foot minimal 1 8 inch separation between tiers roller gravity grip switch turns lamp on or off etc The DVC angulation system provides an optimal viewing and varies intensity environment for easy top to bottom image construction The MAXANT Hot Lamp Techline illuminators may also be positioned in a DVC Corner allows for intense illumina System The DVC Corner System combined with the DVC tion of excessively dark areas Angulation System provides effective use of awkward corner on films It s construction is space DVC corner systems allow for a single viewing panel in steel with a powder coat light the top tier of the corner system and a choice for
208. t easy accurate way to bring the focal zone closer to the surface for enhanced diagnostic detail during ultrasound examinations Material Sonolucent gel Dimensions 10cm x 15cm Weight 0 42 kg 1 1b 1US Patent 5196343 Ultrasound Quality Assurance FLUKE o Biomedical Key features e Complies with the AIUM stan dard for quality assurance e The best performing phantom in the industry for evaluating system and transducer performance e Includes cyst like and solid structures in various sizes Simulates liver tissue scatter ing and attenuation Now available with 0 5 or 0 7 dB cm MHz attenuation coefficients Provides resolution targets at several depths Compatible with all types of imaging equipment including small parts scanners Withstands extreme tempera tures making it ideal for service and quality control use e Three large scanning surfaces Optional accessories 84 318 Scanning Trough for Oil and Water 89 317 Carrying Case insulated for phantom and trough 84 325 1000 Acoustic Standoff 1 0 cm 84 325 2000 Acoustic Standoff 2 0 cm 84 325 3000 Acoustic Standoff 3 0 cm 84 325 Acoustic Standoff 4 0 cm 84 325 1234 Acoustic Standoff Set includes all four 1 cm 2 cm 3 cm and 4 cm Ordering information 84 317 Multipurpose Tissue Cyst Ultrasound Phantom 0 5 dB cm MHz 84 314 Multipurpose Tissue Cyst Ultrasound Phantom Kit consists of phantom either 0 5 dB cm MHz
209. t any point within the system Used to adjust and optimize e Image processing parameters e Viewing conditions Radiography Fluoroscopy Phantoms and Accessories Image evaluation e To evaluate the phan tom image the observer indicates the location of the second spot in each square Correct indication proves that a contrast is actually seen At the transition from visible to invisible it is difficult to decide in which corner the second spot is located and the response equals pure chance The line connecting the central spots with the l smallest visible diameter 0a 1 io and contrast is called the Contrast Detail CD curve For comparison of the imag ing performance of different systems phantom images are made under identical conditions and evaluated by the same observer at the same time The better system will produce an image in which smaller contrasts and details are visible This results in a shift of the CD curve to the lower left part of the image See graph e In the detail vertical direction the diameter of the holes increases step wise and logarithmically from 0 3 mm to 8 mm The image shows 15 rows of spots with increasing detail Detail Diameter mm Contrast Depth mm Contrast detail lines of monitor image and the hard copy image O from the same digital equipment Plexiglas tablet Cylindrical holes of exact diameter and depth tolerances 0 02 mm Radiographic
210. ted on 14 in x 17 in film Gray scale Tests full range of your printer or display Low contrast pattern Digital values of low contrast squares differ from the background density by 9 Weight lt 1lb Diagnostic X Ray Quality Assurance Instruments FLUKE o Biomedical Key features e High contrast resolution e Low contrast discrimination e Linearity of gray scale response e Geometric distortion e Reproduction of continuous fine lines e Digitizer noise A teleradiology PACS quality control test pattern may help identify problems that should be addressed to optimize printer quality Regular interval testing of paper printers with a dedi cated test pattern should be recommended as a part of the quality control program for all teleradiology PACS systems A D Maidment Ph D M Albert Ph D and E J Halpern M D A Quality Control Program for Paper Printers Used with Teleradiology PACS Radiology 205 P November 1997 307 Ordering information 07 450 1024 PACS Digital Test Pattern 1024 x 768 07 450 4000 PACS Digital Test Pattern 4 x 4 K 48 07 451 07 608 and 07 706 X Ray Output Detector Screen Film Contact Mesh and Phantom Penetrometer System 07 451 X Ray Output Detector The 07 451 X Ray Output Detector offers a dynamic means of demonstrating x ray generator 2 performance It is used with a storage or camera TETOR oscilloscope
211. ted white finish is bonded to all steel surfaces to provide durable chip and wear resistant outer surface Highly reflective inner finish provides optimal light distribution Diffusing panel 0 125 inch shatter resistant UL listed translucent thermoplastic Switches The standard two position rocker switch provides manual ON OFF lighting for each viewing area Engineered two tiered fixture design Two tier configurations have a minimal separation of 1 8 inch between tiers allowing for convenient top to bottom image comparison Engineered design for easy servicing Viewing panel is easily removed without tools Fixture is serviceable without having to remove fixture from wall Individual wireway panels can be easily removed for direct access to problem panels Cluster switching Individual rocker control switches are a standard feature and are centrally located at the bottom of the fixture configured in the same layout as the viewing panels they control Film Handling and Storage Biomedical Biomedical 77 201TR to 77 406TS Optional features Film activated three position Provides for manual ON OFF and film activated mode which activates the viewing area when a film is rocker switch inserted into the film grip Master switch Provided master ON OFF control of the entire fixture Hospital grade plug Heavy duty plug specified in certain municipalities Surface mou
212. ters MODE SENS aeecssaae Easy Flow menu AMSE screen 3 65 a iT Eo LO 10 eran Easy Flow menu CT EXP screen 1 23 me ELIP PLUE INTEG HIH MODE MAME MODE SERS EE Easy Flow menu EXP screen 6 2 r HVL 3 76 mmm ra 1 z HYL ET LOW 10mm 5 BODE CHAMBER GENS BEAM Easy Flow menu HVL screen Diagnostic X Ray Quality Assurance Instruments NERO mAx operating modes Radio mode Biomedical Radio mode is used to make measurements on tungsten target aluminum filtered radiographic x ray generators Selections are available for kV peak for the type of generator being tested For example Zero Crossing Single Phase Pulse 75 80 or 90 of kVp modes are available for accurate exposure measurements on difficult x ray machines Radio mode simultaneously measures kVp Avg Exposure kV Eff Exposure time kV Peak kV Peak and mAs Mammo mode Mammo mode is used to make measurements on mammographic x ray generators Mammo mode simultaneously measures kVp Avg Exposure kV Eff Exposure time kV Peak and mAs Fluoro mode Fluoro mode is used to make measurements on fluoroscopic x ray generators Fluoro mode supports both continuous fluoro and pulsed fluoro measurements In the continuous fluoro mode the NERO mAx measures kVp Avg kV Eff exposure rate R min mA and kV Peak In the pulsed fluoro mode the NERO mAx measures kVp Avg kV Eff Exposure rat
213. ters for special applications Regulatory agencies to e Set up the standards for CT scanners and measure their compliance Designed by Jung T Ho Ph D Department of Radiology LAC USC Medical Center Los Angelos California 90033 Biomedical Key features e Mimics human tissue for MRI ultrasound and CT e Designed for training quality The 84 357 Interventional control and demonstrating Triple Modality 3D Abdominal scan techniques Phantom is made from propri e Improve performance of free etary materials which accurately hand abdominal biopsies mimic human tissues under e Test new equipment magnetic resonance imaging e Validate automated biopsy MRI ultrasound and computed eee T f tomography CT It is designed S EMOn SiratE ty reason for a ied R a ano MRI Scan techniques procedures e Optimize imaging protocols The 84 357 contains simulated lungs liver hepatic vessels ribs vertebra kidneys abdominal aorta inferior vena cava muscle fat and interstitial tissues Embedded within the lung and liver are simulated lesions available in a range of sizes and rela tive contrasts Each phantom is protected by a fat equivalent urethane membrane and ABS end caps These features make the phantom durable enough for extended scanning sessions and enable insertion of various surgical instruments as needed Needle not included Material Zerdinee urethane epoxy and ABS D
214. ting both the radiographic and fluoroscopic results Along the sides of the test tool are beads 1 cm inside and outside of the lines started in the corners Ho Pi eb The 07 643 Contrast Imaging Phantom is an accurate easy to use indispensable tool for evaluating image quality and determining that the imaging system is operating at its full potential It will immediately let you know if there s a problem Dimensions WxDxH Outside diameter 23 cm 9 05 in Thickness 1 28 cm 0 5 in Weight 1 26 kg 2 8 1b Radiography Fluoroscopy Phantoms and Accessories Biomedical Key features e Provides the ability to simul taneously check the dynamic range of the video system e Allows users to evaluate during all fluoro modes pulsed non pulsed etc e Provides the ability to check film range and density X ray image Biomedical Key features Provides a test pattern enabling the precise adjustment of many critical parameters of the fluoro Ensure the optimum perfor scopic system i mance of your fluoroscopic e Video level contrast w system with the 07 653 peak whites black level in es Fluoroscopic Imaging Test Shading or vignetting Phantom correction Fs This compact versatile and pou gbiices extremely easy to use phantom Sweep linearity is inventively designed to Frequency response rtur rrection p enabl
215. tion 18 203 Material Acrylic Dimensions WxDxH 10 cm x 12 5 cm x 2 cm thick Weight 1 34 kg 3 1b 18 204 Material BR 12 Weight 1 kg 2 2 lb Dimensions WxDxH 10 cm x 12 5 cm x 2 cm thick 18 238 Material BR 12 Dimensions WxDxH 3 10 cm x 12 5 cm x 2 cm 2 10 cm x 12 5 cm x 1 cm thick 1 10 cm x 12 5 cm x 0 5 cm thick Weight 1 2 kg 2 6 1b 18 238 3070 18 238 5050 Material Tissue equivalent 30 gland 70 adipose Material tissue equivalent 50 gland 50 adipose 18 238 7030 Material tissue equivalent 70 gland 30 adipose 18 224 Material Acrylic Dimensions WxDxH 10 cm x 12 5 cm x 2 cm thick Weight 0 92 kg 2 1b 18 225 Material BR 12 Dimensions WxDxH 2 18 cm x 24 cm x 2 cm thick Weight 1 7 kg 3 8 1b Mammography Quality Assurance Key features 18 203 e Available in either acrylic or tissue equivalent BR 12 material e Should be used to test thickness tracking e The American College of Radiology recommends this type of product in their quality assurance program e Meets MQSA requirements 18 224 e Available in either acrylic or tissue equivalent BR 12 material BR 12 is a designation D R White et al of certain epoxy resin formulations which react to x ray in the mammographic energy range 15 keV to 30 keV in the same manner as human tissue T
216. tion software program is included for use with an IBM PC or compatible 35080M Interface Male two lug BNC Computer interface RS 232 using RJ 45 connector 9 600 baud 8 bit 1 stop no parity xon xoff enables fully programmable operation and waveform display from a PC with optional Excel add in powered when connected to computer Ion chamber input Triax BNC collector and guard positive biased relative to ion chamber body and dosimeter chassis Power 2 1 mm dc power jack power input for an unregulated 9 V 200 mA adapter with a center negative 2 1 mm plug General information Display Two line 20 character alphanumeric PLED polymer LED with 0 5 cm character height indicates all ion chamber kV filter pack identification information numerical measurement results battery level calibration date and other information Weight 6 4 kg 14 Ib Dimensions LxWxH 46 cm x 33 cm x 15 cm 18 in x 13 inx 6 in Diagnostic Ionization Chambers 96035B and 96020C Energy range 96035B 30 kVp to 150 kVp 20 kVp to 50 kVp for mammographic 96020C 30 kVp to 150 kVp Nominal sensitivity 96035B 2 00 R C x 108 R C 1 75 Gy C x 106 Gy C at 22 C and 1013 hPa 2 21 R C x 108 R C 1 94 Gy C x 106 Gy C at 22 C and 1013 hPa flat response suitable for conventional diagnostic radiography and mammography 96020C 2 08 R C x 107 R C 1 82 Gy C x 10 Gy C at 22 C and 1013 hPa optimized for low level image intensif
217. tion needed to check the performance of image intensifier systems A penetrometer permits the determination of system contrast gra 07 706 dient under simulated operating conditions Specifications 07 451 Shock resistant solid state diode detector Power source None required Rise time Less than 1 psec Dimensions WxDxH 3 175 cm x 3 175 cm x 1 27 cm 1 25 in x 1 25 in x 0 5 in Weight 16 6 g 0 58 oz 07 706 Dimensions WxDxH 17 8 cm x 17 8 cm x 4 2 cm 7 in x 7 in x 1 656 in Weight 4 3 kg 9 5 1b Diagnostic X Ray Quality Assurance Instruments FLUKE o Biomedical Key features e Timer calibration single phase three phase or CP units e Loading characteristics e Rectifier malfunctions e Contactor problems e Cable or connector arcing e Shutter calibration etc Optional accessories 07 451 88 222 Cable 6 m 20 ft BNC to BNC 07 706 07 629 1000 Aluminum Blocks two Type 1100 Al 7 125 in x 7 125 in x 0 75 in thick Included accessories 07 706 a Two 7 in x 7 in x 0 75 in blocks of high purity aluminum which represent the equivalent absorption of 26 cm of water and simulate a thick or heavy set patient at 90 kVp A single block is the equivalent of a child or adult chest Aluminum simulates the scatter characteristics of the human body b One 7 inx 7 inx 0 125 in lead beam stop plate When placed in the beam this plate allows automatic brightness con trol machin
218. to display the intensity time rela aN tionship of an x ray beam To use the detector is placed in the x ray beam and the output cable is connected to the oscilloscope input The resulting waveshape patterns are used to calibrate and or diagnose malfunctions in the x ray generator The detector supplies a crisp 200 mV signal at 07 451 standard diagnostic conditions 80 kVp 100 mA This extremely high output permits the simple interpretation of oscilloscope displays Since the detector rise time is better than 1 ms no alteration of the true x ray output pulse shape is introduced 07 608 Screen Film Contact Mesh The 07 608 Film Screen Contact Mesh test tool determines the clarity of the focused image This device allows problems to be identified so that image clarity can be restored It consists of a 35 6 cm x 43 cm 14 in x 17 in copper screen with 0 3 cm 0 125 in mesh embedded in durable plastic for long life use To use simply lay the unit over the cassette radiograph and develop the film Look for screen image clarity across the film Blurring or distortion indicates poor film screen contact et paga 07 706 Patient Phantom Penetrometer System To check the tabletop output of image intensified fluoroscopic equipment properly a simulated body or phantom should be placed between the x ray output meter and the input phosphor The 07 706 phantom protects the phosphor from the direct beam and provides the simulated attenua
219. ty of equipment that costs two or three times more With the RAD CHECK MICRO R measurements are easy to perform and highly accurate Incorporate RAD CHECK MICRO R into your routine QC program for fluoroscopy now and accurately measure what your patient exposures actually are from fluoroscop ically guided procedures This precision electrometer also features a tiltstand for convenient adjustment of display visibility Ranges Low 0 01 mR to 19 99 mR 0 1 R min to 199 9 R min High 0 01 R to 19 99 R 0 1 R min to 1999 R min Standard calibration At 75 kVp with 4 mm Al filtration at 22 C and one atmosphere using 06 524 3000 chamber Reproducibility Within 2 short term over 100 mR to 2 R range 1 mGy to 20 mGy Maximum exposure rate Minimum 90 collection at 20 R sec Electrometer drift Low range 1 mR min typical 6 mR min maximum High range 10 pR min typical 60 pR min maximum Manual reset Resets display to zero Operating temperature 10 C to 40 C 50 F to 104 F Relative humidity 0 to 90 Display 3 5 in x 0 5 in LCD low battery indicator Control Reset button dose or dose rate output selector high or low range selector on off switch Power requirements 9 V alkaline battery gt 50 hour life Dimensions WxDxH 15 25 cm x 6 25 cm x 7 cm 6 in x 6 25 in x 2 75 in Weight 0 51 kg 1 125 Ib Diagnostic X Ray
220. uilt in scanning and single point spot measurement capability it literally does the work of two densitometers Quickly and easily generates control charts and D Log E curves without the use of other densitometers when it external software comes to performance reli i a ability and economy The only 7 eee m Py handheld scanning densi readings y tometer in the industry w E e Provides vital information built in scanning and single n SST point spot measurement capability it literally does the work of two densitometers The 07 444 measures and stores daily film data for up to 20 different x ray film processors for 31 days in its own built in memory Use it to generate and print control charts and D Log E curves directly to a printer without using external software and a computer Set base line target and tolerance levels for each control chart parameter either manually or automatically by scan ning and averaging up to 9 different film strips Includes built in scanning and single point measure ment capabilities Available with AutoSTPP X Ray Film Processor QC Software PROCES2 Contrast Index 01 20 38 D Log E Optional accessories 802013 RS 232 Interface Cable 2 m 7 ft EEN 169072 9 Pin Adapter ee BHRR 169071 25 Pin Adapter peak Tae HHI It tH 88 444 Non Powered Serial Parallel Converter 1 3 5 7 9 11 1 15 17 19 21 23 25 27 29 31 Reference Number a E e J i ie eng Avail
221. ular dose and radiation output rate NERO mAx fluoroscopic Used to perform the following fluoroscopic tests kVp accuracy template beam quality and fluoro exposure rate These templates are easy to use and can be modified to fit the user s needs 22 Diagnostic X Ray Quality Assurance Instruments CE The 4000M X Ray Test Device does it all Simply place the instrument in the x ray beam f make one exposure and it seri ra ally displays kVp Maximum d KVp Average kVp Effective r dose and time The Model i 4000M then automatically resets for the next exposure A CsI photodiode pair provides the kVp measurements through five user selectable filter pairs This ensures optimum accuracy over the entire diagnostic range with minimum filtration dependence Exposure measurements are made with a parallel plate ionization chamber located above the filter wheel Exposure time is measured with quartz crystal accuracy Plus a variety of external ion chambers may be con nected for even greater flexibility Kilovoltage Accuracy Range 1 kV Mo Mo 22 kVp to 35 kVp Mammo generators w 30 u Mo 38 mg cm Polycarbonate W AI tubes 27 kVp to 155 kVp Time Measured during entire exposure Mo Mo tubes 21 kVp to 50 kVp at 90 rise fall of waveform Accuracy Within 2 or 2 ms whichever is greater Range Measured during entire exposure Accuracy 1 ms to 10 seconds at 90 r
222. uoro modes 2 or 1 kV whichever is greater Mammo modes 2 or 0 7 kV whichever is greater Reproducibility 1 std of 5 readings Filtration correction range Dose exposure measurements Units Range Radio Fluoro modes 1 mm Al to 10 mm Al or equivalent Mammo mode O mm Al to 0 4 mm Al added filtration Roentgens grays 0 5 mR to 999 R 5 uGy to 999 Gy Resolution uR 0 01 pGy Accuracy 5 Reproducibility 0 5 std of five readings Filtration correction range Radio Fluoro modes 1 mm Al to 10 mm Al or equivalent Mammo mode 0 mm Al to 0 4 mm Al added filtration kV correction ranges Units Radio Fluoro modes 40 kV to 150 kV Mammo mode Mo Mo 22 kV to 35 kV Dose exposure rate measurements Roentgens or grays per hour minute second pulse Range 8 mR s to 10 R s 70 pGy s to 100 mGy s 130 uR pulse to 160 mR pulse 60 PPS 12 Gy pulse to 1 4 mGy pulse 60 PPS Resolution 1 pR s 0 01 pGy s 0 02 uR pulse 60 PPS 0 2 nGy pulse 60 PPS Accuracy 5 Filtration correction range Radio Fluoro modes 1 mm Al to 10 mm Al or equivalent Mammo mode O mm Al to 0 4 mm Al added filtration kV correction range Units Radio Fluoro modes 40 kV to 150 kV Exposure time radiographic modes Mammo mode Mo Mo 22 kV to 35 kV Milliseconds pulses Range stated accuracy Milliseconds 10 ms to
223. varying in size depth accreditation programs and contrast e Rapid visualization of gray This gray scale ultrasound scale resolution phantom is usable on all diag e Continuous depth from 1 cm nostic ultrasound machines to 12 cm thus allowing user evalua e Carrying case included tion of gray scale sensitivity with a wide range of transducer frequencies This phantom is an ideal training tool for learning optimum system setup and evaluating system performance Masses may be viewed with either a circular or elliptical cross section The mass diameters were selected so the volume imaged ys Patent 5196343 would double as the diameter increased The gray scale levels were selected to achieve a doubling in signal intensity as you move from mass to mass The anechoic masses comply with the ACR accreditation program 84 347 is manufactured from Zerdine a solid elastic polymer whose elastic properties can be controlled independently of its acoustic properties O O 0 Anechoic 9dB 6dB 3qdB 3 dB 6 dB 9dB Test objects have same speed and attenuation as background Specifications Material Zerdine solid elastic water based polymer Freezing point O C 32 F Melting point above 100 C 212 F Scanning membrane Saran based laminate Background Attenuation coefficient 0 5 dB cm MHz 0 05 dB cm MHz Speed of sound 1540 m s 6 m s Contrast O dB Targets Attenuation coefficient 0
224. venient features and capabili ties You can quickly and easily display the lowest and highest temperatures measured by the probe since the unit was turned on Our digital thermometer also enables you to freeze the current temperature reading on the display The thermometer display can be easily illuminated making it perfect for use in the darkroom You can also program the 07 402 for auto or manual shut off The 07 402 Portable Digital Thermometer is a shock resistant solid state unit that needs no adjustments to maintain accuracy Calibration is traceable to the National Institute of Standards and Technology NIST The unit includes a high impact plastic case with a recess for storing one probe and is equipped with a power jack that will accept the optional ac power supply The jack should be used when the unit will be in use for extended periods of time in order to prevent battery failure Specifications Temperature range 40 C to 150 C 40 F to 300 F Resolution 0 1 F Accuracy 0 5 over entire range Display Four digit LED plus decimal point Battery Standard 9 V alkaline or equivalent Dimensions Thermometer WxDxT 7 6 cm x 20 3 cm x 2 9 cm 3 in x 8 in x 1 125 in Display area 5 1 cm x 2 4 cm 2 in x 0 94 in Probe 15 3 cm long 6 in long Weight 3 38 kg 7 44 Ib Factory re calibration available Film Processor Quality Assurance FLUKE o Biomedical Key
225. when recalling a setup Archiving Create a library of waveforms with your comments for easy reference and comparison Store complete replay cycles for analysis of waveform changes Store complete memory content of the ScopeMeter on your PC for backup purposes Waveform comparison Store reference waveforms add operator instructions and send both to the ScopeMeter for waveform comparison and Pass Fail testing Analysis Use cursors perform spectrum analysis or export data to other analysis programs Diagnostic X Ray Quality Assurance Instruments Biomedical Optional accessories 33551 CT filter pack 37351 Linear mammo filter pack 37355 Cadmium K Edge filter pack 37946 Mobile filter pack 38237 Low range filter pack 10100AT 10500AT and 10500AMT The TRIAD TnT X Ray Field Service Calibration QA Kit is a full function x ray dosimeter kit that performs fast highly sensitive measurements It is ideal for govern ment compliance testing troubleshooting repair of diagnostic x ray equipment installa tion and setup of new equipment preven tive maintenance radiographic QA mea surements and measurements required for JCAHO accreditation C The kit performs measurements for all modalities radiographic fluoroscopic mammographic MQSA CT cine and dental The TRIAD TnT Kit comes in three popular configurations e 10100AT is the base level dosimeter kit and
226. wing worksheets kVp accuracy kVp reproducibility Beam quality Breast entrance exposure AEC reproducibility average glandular dose and radiation output rate Is used to perform the following fluoroscopic tests kVp accuracy beam quality and fluoro exposure rate These templates are easy to use and can be modified to fit the user s needs Diagnostic X Ray Quality Assurance Instruments Biomedical System requirements Windows 2000 and above Microsoft Excel 97 2000 One serial port COM1 through COM4 Biomedical The NERO mAx Non invasive NERO mAx X Ray Test Device tests the spectrum of x ray machines on the market today Offering evalu ation of pulsed fluoro cine computed tomog raphy CT portable mammographic dental radiographic fluoroscopic low medium and high frequency machines with a single device the NERO mAx is a benchmark instrument for quality and accuracy This fifth generation quality assurance tool features 100 kHz sampling speed and direct mA mAs measurements The NERO mAx s innovative Easy Flow Menu EFM system and flexible soft keys provide an intuitive user friendly operating environment for quick accurate and easy measurements All measurement modes and functions are dis played on the NERO mAx s super bright LCD and are controlled by the five soft keys directly below the display and three hard keys to the right Seven user selectable measurem
227. y performs x ray leakage tests for diag nostic x ray tube manufactur ers and tube reloaders e Demonstrates product compliance to the Radiation Control Act Standard 17 channel 3 channel or custom designed systems are available 17 chambers mounted around a semicircle of one meter radius provides 180 cover age with overlap between chambers Fast full spherical scan two minutes Direct readout in mR hr Reliable modular construction e Expandable from one to eighteen channels e Highest channel readout System configurations A basic 3 channel leakage radiation system can be assembled from an Ion Chamber Electrometer Module used in combination with one 10970 Mainframe two 70010A Dual Channel Comparator Modules one 70020 Reference Control Module and one High Voltage Power Supply The system can expand up to 18 channels to pro vide a full spherical scan by adding plug in mod ules Listed below are two standard system configura tions a 17 channel and a 3 channel system Any number of channels from three to 18 may be ordered Details of system modules are described in the table Note Typical systems are configured with either 17 channels or 3 channels All systems are custom designed Spare components are recommended On site installation is recommended Calibration source and standard NEMA rack cabinet are required Biomedical 10970 Mainframe The 10970 Mainframe includes a r
228. ystem Once the phantom is imaged simply graph the results to determine any trends that may indicate a degradation of imaging system performance such as a steady but slow change in the fluoro kVp or in the radiographic mAs Dimensions WxDxH 17 78 cm x 17 78 cm x 1 42 cm 7 in x 7 in x 0 56 in Weight 0 5 kg 1 1 1b Radiography Fluoroscopy Phantoms and Accessories Biomedical Key features e Designed specifically with the radiologic technologist in mind e Provides an accurate overall evaluation of image quality consistency Ideal for use in determining subtle degradation in imaging performance Average test time is less than 5 minutes per unit Verifies fluoroscopic moni tor contrast and brightness adjustment Includes pie shaped wedges of varying mesh sizes 20 30 40 60 80 and 100 L in for evaluating high contrast performance Surrounding the mesh are four low contrast masses of different diameters 2 mm 4mm 6mm and 8mm At one edge of the phantom is a small density differ ence patch for a measure of contrast on the films At the opposite edge of the phantom are two monitor adjustment squares each having a low contrast square insert The phantom contains a 1 mm copper attenuator which allows it to simulate the attenuation of an average adult At the corners of the test tool are lines for aligning the light field QC charts are provided for plot
229. z Input current 0 5 A rms Output voltage 6 V dc 0 C to 35 C 32 F to 95 F Storage temperature 35 C to 50 C 31 F to 122 F Operating humidity Physical specifications 20 to 80 RH non condensing Display 320 x 240 Color LCD Size WxDxH Display 15 2 cm x 11 4 cm x 4 45 cm 6 in x 4 5 in x 1 75 in Detector 15 2 cm x 11 4 cm x 4 45 cm 6 in x 4 5 in x 1 75 in Weight Display 0 422 kg 0 93 1b Detector 0 68 kg 1 5 1b Diagnostic X Ray Quality Assurance Instruments FLUKE o Biomedical Optional accessories 3335538 TA TNT12K TNT 12000 with Test Automation 3340639 TA TNT12KWD TNT 12000 Wireless Detector with Test Automation Ordering information Kit 1 TNT 12000 X Ray Test Device Included accessories 1320005000 TNT 12000WD Wireless Detector 1330005000 TNT 12000D Wireless Display 14 445 2 AC Adapters Chargers 50 197 Cable Type A to Mini B USB 50 198 Cable Mini A to Mini B USB 1320003000 Excel Software User Manual on CD 1320033000 Carrying Case 90 183 ZigBee USB Dongle TNT12QRG Quick Start Reference Guide Kit 2 3335774 TNT 12000WD Wireless Detector Included accessories 1320005000 TNT 12000WD Wireless Detector 14 445 1 AC Adapter Charger 50 197 Cable Type A to Mini B USB 1320003000 Excel Software User Manual on CD 1320033000 Carrying Case 90 183 ZigBee USB Dongle TNT12QRG Quick Start Reference Guide Kit 3