Home
click details - EM Euro Medical
Contents
1. around 10 measurements still possible Battery is nearly empty with enduring displaying of battery symbol Instructions Change battery
2. OF FAILURES TROUBLESHOOTING In case of failure or incorrect temperature measurement the following warnings will be indicated on the display Display indicates LO Measured temperature is below 35 C and out of measuring range r Instructions Turn off thermometer by using the ON i j OFF button and turn it on again Retake Il measurement as described on left page Lu Display indicates HI Measured temperature is above r 42 C Display indicates Er i Thermometer was inserted before symbols inclusive sand glass disappeared from display Instructions Wait till Waiting symbol sand glass disappears and till resound of two Beeps ro Display indicates Er 2 Temperature is not registered because of poor physical contact or wrong placement Instructions Prove coincidence of chosen method of measurement Retake measurement after a minute mm he 2 Display indicates Er 3 Malfunction of thermometer Instructions Do not use the thermometer any longer Contact EM Euro Medical GmbH or your authorized specialized dealer ha Lis Display indicates Er 4 Temperature was not measured within 1 minute after thermometer was ready to operate Instructions Prove coincidence of chosen method and practiced measurement Turn thermometer off by using the ON OFF Button Restart the measurement after 1 minute rm be M Display indicates Battery Symbol When blinking battery loses power
3. 11 e mail info euro medical de www em euromedical com INSTRUCTIONS FOR USE WARNING Never use the Penguin as an Ear Thermometer Severe injuries can be caused by insertion into the ear 1 Turn on the Thermometer Press the ON OFF button and wait until all symbols inclusive sand glass disappear on display and two signal tones resound 2 The Thermometer is now ready for use To select the method of measurement press the Mode button the kl arrow changes its position and points to the selected method 3 Position the thermometer in correspondence to the selected method and follow the following instructions and illustrations gt Axilla Place thermometer s probe in the armpit and press the arm to the body gt Oral Place thermometer probe under the tongue and close the mouth gt Rectal F Due to hygienic requirements make use of Penguin Na Probe Covers Lubricate thermometer probe covers with a water soluble glide gel Gently insert the N thermometer tip not more than 1 25 cm into the rectum we recommend lateral position for avoiding too deep penetration differing from illustration 4 A long single beep indicates the ending of measurement The measured result appears on the display 5 To turn off the thermometer press the ON OFF button WARNING Wait at least one minute before taking any other measure ments that the thermometer can cool down on room temperature WARNINGS IN CASE
4. TECHNICAL INFORMATION Measurement time Measurement methods Measurement range Accuracy 3 5 seconds Axilla Oral and Rectal 35 C to 42 C 95 F to 107 6 F Technical 0 1 C tested in calibrated water bath Clinical Complies with ASTM E 1112 86 standard requirements Required operating environment for functionality Temperature 10 C to 40 C 50 F to 104 F Air pressure 700 to 1060 hPa Humidity 15 to 95 no condensing Storage environment Temperature 20 C to 50 C 4 F to 122 F Air pressure 700 to 1060 hPa Humidity 15 to 95 non condensing Design Display LCD 18 5 mm x 21 5 mm Dimensions 18 5 cm x 3 5 cm x 4 4 cm Weight 114 gr without battery Materials Case ABS plastic Other information Internally powered equipment Battery life Mode of operation Device is not suitable for use Water desity WARRANTY Probe tip Stainless steel 304 9 V Battery approximately 1 000 measurements using alkaline battery continuous operation In addition to flammable anesthetics as well as with air or oxygen or mixture of nitrous oxide Thermometer IPXO Applied part IPX7 User manual Penguin Instant Thermometer You can now measure body temperature exactly in just 4 seconds only with the Penguin Instant Thermometer whilst using the three classic measuring methods Axillar oral or rectal The Penguin Instant Thermometer is especially el
5. igible for unproblematic and accurate measurements with babies and small children ee T P nguin Penguin Reference Method enables faster evaluation of fever trend The unique probe of this thermometer provides precise measuring of inner body temperature by practicing rectal measurement Penguin Reference Method includes an oral and rectal measurement Those should be taken in between one minute interval for cooling down the thermometer at room temperature Due to these recorded two values the effect of antipyretics can be recognized by a subsequent oral measurement Accordingly inferences to a rectal measurement can be anticipated This is important because the change of temperature can be recognized faster oral than by the rectum Due to a higher body mass around the anus cooling down of body will be processed slower Thus Penguin Reference Method avoids any unnecessary additional antipyretics EM Euro Medical guarantees that this thermometer will operate as described in this manual for a period of one year from the date of purchase when used and maintained in accordance with the instructions herein Please submit the thermometer in case of a complaint with original invoice to authorized specialist dealer or directly to EM Euro Medical EM Euro Medical Vertriebsgesellschaft fur Medizinische Produkte mbH Untere SchloBhalde 9 D 78351 Bodman Ludwigshafen Germany Tel 0049 0 7773 93881 0 Fax 0049 0 7773 93881
Download Pdf Manuals
Related Search
Related Contents
Cisco Systems PGW 2200 Installation & Configuration Guide Bedienungsanleitung Mode d'emploi Manuale d Installation and User Guide for Operating Instructions - VEGASON 62 - 4 … 20 mA/HART - two-wire LINDY User Manual User Manual - UNC Center for Public Health Preparedness Manual del usuario - SENSUS Pain Management Copyright © All rights reserved.
Failed to retrieve file