1. 6 Specification MODEL SEKURY C 800VA capacity A W 480W 230VAC INPUT Voltage Voltage Range 0 300VAC Voltage Regulation T Batt Mode aie OUTPUT Frequency 50Hz Frequency Regulation Batt 1 Hz Mode Output Waveform Modified Sinewave Battery Type amp Number 12V 9Ah x 1pc BATTERY Per a 8 minutes depending of load Recharge Time 3 5 hours to 90 after complete discharge RANSFER IME Typical lt 4ms AC Mode Green LED lighting INDICATOR Battery Mode Green LED flashing Fault Low Battery Battery Red LED lighting Replacement Battery Mode Sounding every 10 seconds Low Battery Sounding every second AUDIBLE Overload Sounding every 0 5 seconds ee Battery Replacement Sounding every 2 seconds Fault Continuously Sounding P Under Over Voltage Spike and Surge Suppression eee ul Protection Overload EMI RFI Filter and Short Circuit Protection Dimension 345x134x163 PHYSICAL DxWxH mm Net Weight kgs 7 2 Operating 0 40 C at full load 0 90 relative humidity ENVIRONMENT Environment non condensing Noise Level lt 40dB INTERFACE RS232 See the list as below 10 7 Software Installation Winpower is a unique uninterruptible power supply UPS control software that offers you unprecedented convenience for the control of any UPS E Software compatible with Windows 95 98 NT 2000 ME XP Linux x86 Compaq
2. ON position otherwise the UPS will be disabled and your equipment will not be protected during a power failure 5 Trouble Shooting Symptom Possible Cause Remedy No LED display 1 Missing battery 1 Charge battery up to 8 hours on the front panel 2 Battery defect 2 Replace with the same type of battery 3 Power switch is not pressed at least 5 seconds 3 Press and Hold power switch for at least 5 seconds Alarm buzzer Overload of the UPS Verify that the load matches the UPS beeps capability specified in the specs continuously when AC supply is normal When power f1 Overload of the UPS 1 Remove some noncritical load failure back up time is shorten 2 Battery voltage is too low 2 Charge battery 8 hours or more 3 Battery defect due to high temperature operation environment or improper operation to battery 3 Replace with the same type of battery Communication lost between 1 Software is not installed well Check the setting of the software UPS and computer 2 Cable is not properly connected 2 Check the RS 232 cable is firmly connected to COM1 COM2 of the computer and confirm the setting again Mains normal 1 Fuse is blown k Replace the same type of fuse but red and green LEDs are 2 Power cord is loose flashing 2 Reconnect the power cord properly
3. True64 IBM AIX 4 3x 5x FreeBSD 4 x UnixWare IA32 Sun Solaris x86 2 6 7 8 9 Sun Solaris Sparc 2 6 7 8 9 HP US 11 x amp MAC Features Saves files before shutdown occurs Power flow display for monitoring UPS status e Scheduled system shutdown restart e Scheduled UPS test e Warning notification via E mail Pager e Warning notification via Broadcast e Password security protection e Remote Monitor Control via LAN e Safety to shutdown Multi systems e Selectable User Interface Background e UPS Parameter setting e Record logs for analysis E Winpower Soyntec Passion for In valizada Soyntec y Instalando hello27 jar 11 Installing Commander Pro is a simple process 1 Install CD ROM 2 Type in Serial No 511C1 01220 0100 478DF2A to install the software 12
4. UPS and decrease its life The UPS surpasses the competition in producing the smoothest transition from sine wave to step sine wave Major features of SEKURY C Series are listed as follows Microprocessor control guarantees high reliability Auto turn on at first plug in Provide boost and buck AVR to stabilize input voltage Built in Smart RS 232 Communication Port Smart software bundled to monitor UPS with powerful features Provide lightning surge overload and short circuit protection Green Power function for energy saving Auto restart when AC recovery Power Switch Off delay Function 2 age bat CAUTION This UPS utilizes voltages that may be hazardous Do not attempt to disassemble the unit The unit contains no user serviceable parts Only factory service personnel may perform repairs Connection to any other type of receptacle other than a two pole three wire grounded receptacle may result in a shock hazard as well as violate local electrical codes Inthe event of an emergency turn the power switch to the off position and disconnect the power cord form the AC power supply to properly disable the UPS Avoid placing the UPS in locations where there is standing or running water or excessive humidity Do not allow liquids or any foreign object to enter the UPS Do not place beverages or any other liquid containing vessels on or near the unit Do not plug the UPS power cord into itself Do n
5. UPS to charge fully by leaving it plugged in for at least 8 hours 8 hours 4 Computer Connection Connect one computer related device into each of the power receptacles supplied on the back of the UPS maximum of three devices 5 Modem Phoneline Connection Plug incoming internet line into the In socket at the back of the SEKURY C UPS Use one more Internet line cable and plug one end of the Internet line cable to the Out socket at the back of SEKURY C UPS Plug the other end to the modem input socket as shown Incoming Internet line 6 Serial Cable Connection To allow for unattended system shutdown for your operating system connect the serial cable as per diagram below 7 Turn On Off SEKURY C Series will be turned on automatically at first plug in At this moment press and hold power switch for 5 seconds lightly to turn off the UPS To turn on the UPS again press and hold the power switch for 5 seconds Please DO NOT punch it for extended life of the power switch 8 DC Start To start the UPS when AC utility power is not available and battery is fully charged press and hold the power switch for 5 seconds 9 Green Power Function All SEKURY C Series are equipped with Green Power Function If no load connects to the UPS it will automatically shut down in 5 minutes for energy saving while power failure The UPS will restart while AC recovery Note The Power Switch must be kept in the
6. Soyntec y User Manual SEKURY C 800VA 1 Introduction SEKURY includes a software which can remote and control UPS through LAN get warning notifications through broadcast and mobile phone multi shutdown PCs and schedule UPS self test This unique software provides complete power protection for computer system while power failure The line of UPS provides boost and buck AVR to stabilize input voltage and full protection to your computers and peripheral devices such as scanners monitors modems etc from losing valuable data as a result of power failures In the event of a utility failure such as a blackout brownout or power sag when the lights in a room dim for a moment the UPS rapidly transfers your computer equipment to an alternative power source This allows you adequate time to save files exit programs and properly shut down your system Under normal conditions when the available AC voltage is within limits that are appropriate for your equipment the SEKURY C UPS maintains it s battery charge and otherwise remains invisible in it s operation When the power supply is transferred from utility AC power to backup battery DC power the waveform is altered with minimal transfer time from a normal sine wave to a step sine wave According to research a rough wave transition or an imperfect step sine wave could cause a voltage transient Eventually this voltage transient could damage the MOS circuitry within the
7. ot attach a power strip or surge suppressor to the UPS Do not attach non computer related items such as medical equipment life support equipment microwave ovens or vacuum cleaners to the UPS To reduce the risk of overheating the UPS do not cover the UPS cooling vents and avoid exposing the unit to direct sunlight or placing the unit near heat emitting appliances such as space heaters or furnaces Unplug the UPS prior to cleaning and do not use liquid or spray detergent To reduce the risk of overheating the UPS do not cover the UPS cooling vents and avoid exposing the unit to direct sunlight or installing the unit near heat emitting appliances such as space heaters or furnaces Unplug the UPS prior to cleaning and do not use liquid or spray detergent Do not dispose of battery or batteries in a fire The battery may explode Do not open or mutilate the battery or batteries Released electrolyte is harmful to the skin and eyes It may be toxic A battery can present a risk of electrical shock and high short circuit current The following precautions should be observed when working on batteries 1 Remove watches rings or other metal objects 2 Use tools with insulated handles 3 Wear rubber gloves and boots Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions Keep unauthorized personnel away from batteries When replacing bat
8. teries replace with the same number of the sealed lead acid batteries 3 System Description LED Indicators amp Audible Alarms z LED Condition Audible Alarm Green Red AC Mode E None Battery Mode A Sounding every 10 seconds Low Battery E Sounding every second Overload Sounding every 0 5 second Battery Replacement E Sounding every 2 seconds Fault E Continuously sounding Mi LED on A LED flash Back Panel 1 Output receptacles one Schuko 3 RS 232 Communication Port 2 AC input with AC fuse 4 Phone Modem Surge Protection 4 Installation and Operation 1 Inspection Remove the UPS from its packaging and inspect it for damage that may have occurred during shipping If any damage is discovered repack the unit and return it to the place of purchase Placement Install the UPS unit in any protected environment that provides adequate airflow around the unit and is free from excessive dust corrosive fumes and conductive contaminants Do not operate your UPS in an environment where the ambient temperature or humidity is high On the other hand place the UPS unit away from monitor at least 20cm to avoid interference Charging This unit is shipped from the factory with its internal battery fully charged however some charge may be lost during shipping and the battery should be recharged prior to use Plug the unit into an appropriate power supply and allow the