1. ain P am Tripp Lite Pp l 1111 West 35th Street TRI LITE Chicago IL 60609 USA POWER PROTECTION i Telephone 773 869 1234 _ nnn E mail saleshelp tripplite com Model PDUMH15NET2 Single Phase Switched PDU 15A 120V 1U Horizontal Rackmount 8 NEMA 5 15R outlets NEMA 5 15P input plug Highlights e Switched 15A 120V PDU 1U horizontal rackmount format e Reports voltage frequency amp load level via ethernet interface e Visual current meter Reversible housing e NEMA 5 15P input with attached 12 ft 3 6m line cord e 8 NEMA 5 15R switched outlets with cord retention brackets e Temperature humidity and contact closure monitoring options Description Tripp Lite single phase Switched PDU Power Distribution Unit offers advanced network control and monitoring with the ability to turn on turn off recycle or lock out power to each individual receptacle monitor site electrical conditions and remotely monitor output power consumption PowerAlert interface supports remote control and custom notification of user specified conditions via email secure web SNMP Telnet or SSH interface Individually switched outlets can be controlled in real time to remotely reboot unresponsive network hardware or be custom programmed for user defined power up and power down sequences to ensure proper startup of interdependent IT systems and prevent inrush related overloads as network equipment is first energized Unused PDU outlets can be
2. Duty Power cord IEC 320 C19 to NEMA 5 15P 1 P006 010 10 ft 18AWG Power cord NEMA 5 15P to IEC 320 C13 1 P010 012 12 ft 18AWG Power cord NEMA 5 15P to IEC 320 C13 1 More information including related products owner s manuals and additional technical specifications can be found online at www tripplite com en products model cfm txtModellD 5452 Copyright 2013 Tripp Lite All rights reserved All trademarks are the sole property of their respective owners Tripp Lite has a policy of continuous improvement Specifications are subject to change without notice Photos may differ slightly from final products
3. ARMS amp SWITCHES Front panel LEDs PHYSICAL Shipping Dimensions HWD in Shipping Dimensions HWD cm 8 LEDs display power on off status for each outlet Digital Current Meter display shows total output power consumption in amps 2 13 x 11 81 x 20 47 5 4 x 30 x 52 Shipping weight Ibs 6 9 Shipping weight kg 3 1 Unit Dimensions 1 75 1U x 17 5 x 4 25 HWD in Unit Dimensions 4 44 x 44 4 x 10 8 HWD cm Unit weight Ibs a2 Unit weight kg 2 36 Material of Steel construction Style Rackmount Form factors 1U rackmount supported PDU Form Factor Horizontal 1U 2U etc ENVIRONMENTAL Relative Humidity Up to 95 non condensing COMMUNICATIONS SNMP compatibility Yes pre installed SNMPWEBCARD provides remote monitoring via web telnet and SNMP management systems Remote management gives user ability to turn connected loads on or off individually SPECIAL FEATURES Appearance Black 1U rackmount steel chassis CERTIFICATIONS Certifications Tested to UL 60950 1 USA CAN CSA C22 2 NO 60950 1 Canada Class A Part 15 Emissions NOM Mexico ROHS compliant WARRANTY Product Warranty 2 year limited warranty Period Worldwide Related Items Optional Products Related Model Description Qty WEXT3 PDU NET 3 Year Extended Warranty For Switched PDUs ending with NET 1 WEXT5 PDU NET 5 Year Extended Warranty For Switched PDUs ending with NET 1 ENVIROSENSE Monitors temperature humidity and c
4. TCH door sensors e DHCP Manual configuration support e 10 100 Mbps auto sensing e Real time clock backup maintains the time of day and date even if the PDU is unpowered e Tiered access privileges allow an administrator and a guest to login via web browser e Alert notifications via email or SNMP traps offer immediate event notification e Firmware upgrade ability supports future product enhancements e Supports HTTP HTTPS PowerAlert Network Management System SMTP SNMPv1 SNMPv2 Telnet SSH FTP DHCP BOOTP NTP protocols e Fully compatible with FREE PowerAlert Network Management System NMS Software e 1U horizontal rack installation supported in 2 or 4 post racks with included mounting brackets e Mounting brackets support wall mount and under counter installation in many applications e Included cord retention brackets and wire ties Specifications OVERVIEW PDU Type Switched OUTPUT Frequency 50 60 Hz compatibility Output nominal 120V voltage Outlet quantity type 8 NEMA 5 15R Outlet Type NEMA 5 15R Customized load management receptacles 8 individually controlled outlets INPUT Nominal Input 120V AC Voltage s Supported PDU Input Voltage 100 120 127 Maximum Input Amps 15 A Maximum Input Amps A Details 15A maximum Agency de rated to 12A continuous PDU Plug Type NEMA 5 15P Input cord length ft 12 Input cord length m 3 66 Voltage compatibility 120 VAC Phase Single Phase LEDS AL
5. electronically locked off to prevent the connection of unauthorized hardware PDU output current consumption in amps is continuously displayed locally via visual meter and remotely via web network interface to warn of potential overloads before critical IT mains or branch breakers trip Applications e Ideal means of powering networking equipment in datacenters computer rooms and network closets Package Includes e PDU with attached 5 15P input power cord e 1U mounting brackets cable retention ears and wire ties e PowerAlert software and configuration cable e User manual Features e 15A 120V Switched Power Distribution Unit PDU with built in web network interface Agency derated to 12A continuous e Attached NEMA 5 15P 120V single phase input 12 ft 3 6m cord e 1U horizontal rackmount form factor e 8 switched NEMA 5 15R outlets e Supports power on power off or reboot of each outlet on a real time or programmable basis e Enables reboot of locked equipment custom power on power off sequences load shedding of optional loads and disabling unused outlets e Network interface provides PDU control and data regarding input voltage and total output load level in amps e Digital display continuously reports total output load level in amps e Supports user specified alarm notification thresholds e In rack environmental reporting with optional ENVIROSENSE temperature humidity sensor and rack access notification with up to 4 optional SRSWI
6. ontact closure inputs Requires UPS with 1 SNMPWEBCARD monitored PDU or switched PDU SRSWITCH Magnetic Door Switch Kit for front and rear doors requires ENVIROSENSE 1 P006 006 13LA 6 ft 18AWG Power cord NEMA 5 15P to IEC 320 C13 Left Angle 1 P006 006 13RA 6 ft 18AWG Power cord NEMA 5 15P to IEC 320 C13 Right Angle 1 P023 001 1 ft 14AWG Power Adapter cord NEMA L5 15R to NEMA 5 15P 1 P022 001 1 ft 18AWG Power Extension cord NEMA 5 15R to NEMA 5 15P 1 P007 002 2 ft Heavy Duty 14AWG Power cord IEC 320 C13 to NEMA 5 15P 1 P030 002 5 5 Pack of 2 ft 18AWG Power Cords NEMA 5 15P to IEC 320 C13 1 P006 003 3 ft 18AWG Power cord NEMA 5 15P to IEC 320 C13 1 P006 004 4 ft 18AWG Power cord NEMA 5 15P to IEC 320 C13 1 P006 004 BL 4 ft 1BAWG Power Cord NEMA 5 15P to IEC 320 C13 with Blue Connectors 1 P006 004 GN 4 ft 18AWG Power Cord NEMA 5 15P to IEC 320 C13 with Green Connectors 1 P006 004 RD 4 ft 1BAWG Power Cord NEMA 5 15P to IEC 320 C13 with Red Connectors 1 P006 004 YW 4 ft 1BAWG Power Cord NEMA 5 15P to IEC 320 C13 with Yellow Connectors 1 P006 006 6 ft 18AWG Power cord NEMA 5 15P to IEC 320 C13 1 P006 006 2 6 ft AC Power Splitter Cable NEMA 5 15P to 2 x IEC 320 C13 1 P006 006 515MF 6 ft Piggyback Power Cord NEMA 5 15P R to IEC 320 C13 1 P007 006 6 ft Heavy Duty 14AWG Power cord IEC 320 C13 to NEMA 5 15P 1 P007 010 10 ft Heavy Duty 14AWG Power cord IEC 320 C13 to NEMA 5 15P 1 P034 010 10 ft 14AWG Heavy
Download Pdf Manuals
Related Search
Model models model mayhem model 3 model y tesla model number of this laptop modelo beer model context protocol modelscope modelsim model y 2025 model s plaid model o software modelo negra model cars modelling model trains model number for my pc modelo especial models resource model name of my laptop model roundup model 3 tesla model electronics model society model united nations