Home
Wireless Forecast Station Model: 308-1451
Contents
1. Forecast station However due to the nature of the Earth s lonosphere reception is very limited during daylight hours The Forecast station will search for a signal every night when reception is best The WWVB radio station derives its signal from the NIST Atomic Clock in Boulder Colorado A team of atomic physicists continually measures every second of every day to an accuracy of ten billionths of a second a day These physicists have created an international standard measuring a second as 9 192 631 770 vibrations of a Cesium 133 atom in a vacuum This atomic clock regulates the WWYVB transmitter WWVB RECEPTION ICON with full signal strength will appear on screen in front of the date when A the reception of time is successful The tower icon will show solid when the Forecast station has received the WWVB signal No tower icon is shown The Forecast station was unable to receive a signal at this time Reposition the Forecast station for better signal reception or try again at bedtime The Forecast station will start searching at UTC 07 00 and if no reception on the first attempt they will try again at 08 00 09 00 and 10 00 Each attempt will be at least 2 minutes and the most will be 10 minutes If there is no signal or too much interference the receiver will only be on for 2 minutes If the signal is good it may catch a signal in ABOUT 2 3 minutes If the signal is marginal it will try to catch a signal for up to 10 minutes IMPORTANT W
2. examined which is not in need or repair you will be charged for the repairs or examination The owner must pay any shipping charges incurred in getting the La Crosse Technology Ltd product to a La Crosse Technology Ltd authorized service center La Crosse Technology Ltd will pay ground return shipping charges to the owner of the product to a USA address only The La Crosse Technology Ltd warranty covers all defects in material and workmanship with the following specified exceptions 1 damage caused by accident unreasonable use or neglect including the lack of reasonable and necessary maintenance 2 damage occurring during shipment claims must be presented to the carrier 3 damage to or deterioration of any accessory or decorative surface 4 damage resulting from failure to follow instructions contained in the owner s manual 5 damage resulting from the performance of repairs or alterations by someone other than an authorized La Crosse Technology Ltd authorized service center 6 units used for other than home use 7 applications and uses that this product was not intended or 8 the products inability to receive a signal due to any source of interference This warranty covers only actual defects within the product itself and does not cover the cost of installation or removal from a fixed installation normal set up or adjustments claims based on misrepresentation by the seller or performance variations resulting from installatio
3. 100mb Resolution 1mb a Measuring time interval every 12 minute WARRANTY INFORMATION La Crosse Technology Ltd provides a 1 year limited warranty on this product against manufacturing defects in materials and workmanship This limited warranty begins on the original date of purchase is valid only on products purchased and used in North America and only to the original purchaser of this product To receive warranty service the purchaser must contact La Crosse Technology Ltd for problem determination and service procedures Warranty service can only be performed by a La Crosse Technology Ltd authorized service center The original dated bill of sale must be presented upon request as proof of purchase to La Crosse Technology Ltd or La Crosse Technology Ltd s authorized service center La Crosse Technology Ltd will repair or replace this product at our option and at no charge as stipulated herein with new or reconditioned parts or products if found to be defective during the limited warranty period specified above All replaced parts and products become the property of La Crosse Technology Ltd and must be returned to La Crosse Technology Ltd Replacement parts and products assume the remaining original warranty or ninety 90 days whichever is longer La Crosse Technology Ltd will pay all expenses for labor and materials for all repairs covered by this warranty If necessary repairs are not covered by this warranty or if a product is
4. LA CROSSE TECHNOLOGY Wireless Forecast Station Model 308 1451 Instruction Manual INTRODUCTION The Wireless Forecast Station features radio controlled time dual time alarms sunrise sunset barometric pressure in numbers and pressure graph with 12 hour history forecast icons indoor outdoor temperature and humidity with high and low alarms Four forecast Icons based on temperature amp air pressure readings suggest what kind of weather to expect and what to wear This Forecast Station will never keep you guessing on current or future weather conditions FORECAST STATION ay Cid ss 8 28 TUE ae OME se 2 an Ws Ho isga 84 gt YY OUTDOOR TEMPERATURE HUMIDITY TRANSMITTER TX14TH TABLE OF CONTENTS INTRODUCTION FORECAST STATION OUTDOOR TEMPERATURE HUMIDITY TRANSMITTER TX14TH FEATURES INITIAL SETUP WWVB RADIO CONTROLLED TIME WWVB RECEPTION ICON MANUAL SIGNAL SEARCH FUNCTION BUTTONS PROGRAM MENU WWVB RECEPTION ON OFF TIME ZONE DAYLIGHT SAVING TIME INDICATOR 12 OR 24 HOUR TIME FORMAT FAHRENHEIT CELSIUS SET TIME SET CALENDAR CITY SELECTION TIME ALARM SET DEACTIVATE ALARM SNOOZE FROST ALARM OUTDOOR TEMPERATURE ALARMs TEMPERATURE TREND ICONS CHANNEL SCROLL ABSOLUTE PRESSURE NUMBER UNIT OF MEASURE PRESSURE HISTORY 12 HOUR PRESSURE GRAPH WEATHER FORECAST ICONS FORECAST TENDANCY ARROWS CLOTHING INDEX MIN MAX TEMPERATURE HUMIDITY DATA VIEW RESET LOW BATTERY MULTIPLE OUTDOOR TRANSMITTERS CHAN
5. NEL SCROLL OTHER FORECAST STATION ICONS INSTALL BATTERIES INOUTDOOR TRANSMITTER INSTALL BATTERIES IN THE FORECAST STATION CARE AND MAINTENANCE POSITION OUTDOOR TRANSMITTER POSITION FORECAST STATION SPECIFICATIONS ACCURACY WARRANTY FCC DISCALIMER APPENDIX A CITY LIST OCOOOONDDMHDODOAUHUHAKR RWW SBA FEATURES Atomic Clock 7 Time Zones AST EST CST MST PST AKST HAST Calendar Month date 2000 2099 Default Year 2010 Time hour minute Indoor Temperature Humidity Wireless Outdoor Temperature Humidity C F selectable Alarm and snooze Function Weather Forecast Sunny Slightly Cloudy Cloudy Rain or Snow History chart for Pressure Low Battery indicator Main unit Transmitter Display when out of battery Temperature and humidity trends High Low Daily records Comfort indicator 250 major US cities sunrise sunset Clothing index e Low battery icon for Forecast Station and Transmitter e Sits on desktop or tabletop e 308 1451 requires 3 AA Alkaline batteries not included e TX14TH requires 2 AA Alkaline batteries not included INITIAL SET UP Note The Forecast Station will display the fisherman icon lines etc before batteries are installed These items are painted on the screen 1 Insert 3 AA batteries not included into the Forecast station see Install Batteries in the Forecast Station The Forecast Station will light up and show pressure indoor temperature humidity and c
6. PMENT All rights reserved This handbook must not be reproduced in any form even in excerpts or duplicated or processed using electronic mechanical or chemical procedures without written permission of the publisher This handbook may contain mistakes and printing errors The information in this handbook is regularly checked and corrections made in the next issue We accept no liability for technical mistakes or printing errors or their consequences All trademarks and patents are acknowledged Printed in China APPENDIX A UNITED STATECITY LIST BY STATE coce STAtUOTY stateorr iw AARSET NEWA TRENTON FORT SATH UTTLE ROCK FRANIFORAT UDUVOTON LANSING ROGERS CITY MANQUE TTE TRAVERSE CITY 5 testwoct oF WaASHNGTON a EA DRUT GRAND PORTAGE INTERNATIONAL FALLS Vhs OL JEFF ORSON CITY UTTLE AMERUCA penne a A WEST VELLOWSTONE vE POMAR WUY SPRINGFIELD GREENWOOD PUNTEVILLE PAPO eC TON JACKSON OO WAL IFA TUPELO c YELLOW E OTTAWA SleURY THUNDER BAY TORONTO OMMALOTTE TOWN GREENVELE MONTREAL Qutfec SOUTH DAROTA FE Cote SOU FALLS 6 Png Bead RAPD city FAYETTEVILLE TENNESSEE WEMINGTON WINSTON SALEM WELAMSTON z 53 Q s MASHVELE CMATTENOOGA MEO CiTy NOIRA GUADALUPE MEWPres MERMOGELO a3
7. ash in the time display 2 Press and release the or button to turn DST to OFF 3 Confirm with the SET button and move to 12 24 hour time format On 12 OR 24 HOUR TIME FORMAT The Time may be displayed in 12 hour or 24 hour format Default is 12 hour time Note When in 12 hour format AM or PM will show in front of the hour 1 12Hr will flash in the time display 2 Press and release the or button to select 24 hour time 3 Confirm with the SET button and move to Fahrenheit Celsius FAHRENHEIT CELSIUS Select to have temperature displayed in Fahrenheit or Celsius Default is Fahrenheit 1 F will flash in the time display o 2 Press and release the or button to select Celsius F 3 Confirm with the SET button and move to Set Time SET TIME To set the time manually The hour digit will flash Press and release the or button to select the hour Press and release the SET button to move to the minutes The minute s digit will flash Press and release the or button to set the minutes Press and release the SET button to move to the seconds The seconds digit will flash Press and release the or button to reset the seconds to zero Confirm with the SET button and move to Set Calendar ooNDNA ON gt SET CALENDAR The date default of the Forecast station is 1 1 2010 To set the calendar 1 The year will flash 2 Press and release the or button to set t
8. e shown next to the indoor temperature and outdoor temperature readings QP CHANNELS AUTO SCROLL CH Channels The Forecast Station can receive up to 3 outdoor transmitters Extra TX14TH sensors may be found online or at your retailer to monitor remote temperature in up to 3 locations within a 200 ft wireless range of the forecast station When more than one transmitter is used set each transmitter to a different channel number then hold the CH button for 5 second to search for the transmitters View Channels press the CH button to select Ch1 Ch2 Ch3 or auto channel scroll Auto scroll channel will show a circling arrow below the channel number and will rotate through each channel approximately every 5 8 seconds ABSOLUTE BAROMETRIC PRESSURE NUMBER Barometric Pressure is read by the Forecast Station The numeric pressure value adjusts automatically as the forecast station reads changes in air pressure Since this number is absolute pressure it may not be the same as a local reporting station that reads in relative pressure Note The number cannot be calibrated Absolute Pressure is measured in a vacuum without the influences of terrain weather water foliage and elevation The air pressure it would be consistent at every elevation and decrease as it went higher Relative Pressure is a combination of air pressure and altitude Relative air pressure will make readings in local areas relative to each other to allow for proper
9. es each day starting at midnight 12 00 AM The forecast station automatically resets the min max temperatures at midnight 12 00 AM View MIN MAX data Press and release the MAX MIN button to view the Maximum Minimum then Current Indoor and Outdoor Temperatures Multiple Transmitters Press and release the CH button to select the desired outdoor channel to view the Minimum and Maximum Outdoor Temperatures Press and release the MAX MIN button to view the Maximum Minimum then Current Temperatures for that channel Reset all MIN MAX data Hold the MAX MIN button for 5 seconds and the Indoor and all Outdoor Minimum and Maximum Temperatures will be reset manually to Current temperatures LOW BATTERY 2 When this icon appears in the indoor IN reading section replace the batteries in the Forecast Station When this icon gt appears in the outdoor OUT readings section replace the batteries in the outdoor transmitter USE MULTIPLE OUTDOOR TRANSMITTERS The Forecast station will accommodate up to three remote outdoor transmitters TX14TH The channel selection button allows you to easily see the temperature in various locations outdoors baby s room greenhouse basement etc To connect multiple remote transmitters to the Forecast station 1 Remove the battery cover from all the transmitters Leave battery covers off until all transmitters are received by the Forecast station 2 Set the first outdoor transmitter to C
10. forecasting UNIT OF MEASUREMENT InHg or hPa Hold the HISTORY button for 5 seconds to switch from InHg inches or mercury or hPa Hectopascal for the numeric pressure display and the pressure graph Inches of Mercury is common for weather reports and aviation in the United States Hectopascal is equivalent to millibar and commonly used to measure atmospheric pressure outside the United States PRESSURE HISTORY Press and release the HISTORY button to E a ea view the past 12 hours of numeric pressure history Pa gog e Inthe small box to the right of the numeric pressure a number 0 from 0 to 12 will appear 0 is current pressure 1 through 12 reflects the history in one hour increments Note The history graph and forecast icons will not change when you view pressure history 12 HOUR PRESSURE HISTORY GRAPH The bar chart indicates the air pressure history trend over the last 12 hours in 5 steps Oh 1h 2h 3h 6h amp 12h The columns represent the change in InHg or hPa gt 0 18 m on readings at specific times a The 0 in the middle of this scale is equal to the current pressure and each bar represents how high or low in InHg or hPa the past pressure was compared to the current SS pressure wwf 12 6 3 2 1 0 Read the graph from left to right If the bars are rising it means that the weather is getting better due to the increase of air pressure If the bars
11. fort statement is based on the indoor humidity WET amp Humidity is above 64 COMFORTABLE Humidity is between 43 and 64 DRY Humidity is below 42 F Aa 1s Us TOY YY ALARMS There are 9 different alarms that may be individually set on this forecast station Time Alarm 1 Time Alarm 2 Frost Alarm High Temperature Alarm CH 1 Low Temperature Alarm CH 1 With additional TX14TH transmitters a High Temperature Alarm CH 2 Low Temperature Alarm CH 2 High Temperature Alarm CH 3 Low Temperature Alarm CH 3 TIME ALARM This forecast station has two individual time alarms Press and release the ALARM button to enter Alarm mode Alarm 1 A1 will show after the alarm time Press and release the ALARM button again and Alarm 2 A2 will show after the alarm time SET TIME ALARM 1 Press and release the ALARM button once to enter Alarm mode The Alarm Time and A1 will show 1 HOUR Hold the ALARM button for 3 seconds The Hour will flash Use the or button to set the Hour Be sure to set the Hour correctly for AM or PM Press and release the ALARM button once 2 MINUTES The Minutes will flash Use the or button to set the Minutes Press and release the ALARM button once 3 ACTIVATE Press and release the ALARM button to enter the correct Alarm mode Press and release the button and the alarm icon will appear above the time alarm 1 below the time alarm 2 The number in the bell icon
12. g will void the warranty If the Forecast station does not work properly change the batteries and or check the a c cord connection POSITION THE OUTDOOR TRANSMITTER The remote temperature transmitter should be mounted vertically to avoid damage WALL MOUNT Choose a location for the transmitter that is within range of the Forecast station and under an overhang for accuracy Install one mounting screw not included into a wall leaving approximately inch 12 7mm extended Place the transmitter onto the screw using the hanging hole on the backside Gently pull the transmitter down to lock the screw into place fi hhh TIT TETT TTT hy T SAA l ut NOTE Always ensure that the transmitter locks onto the screw before releasing To achieve a true temperature humidity reading mount where direct sunlight cannot reach the outdoor transmitter Mount the outdoor transmitter on a North facing wall or in any well shaded area Under an eave or deck rail work well The maximum transmitting range in open air is 200 feet 60 meters Obstacles such as walls windows stucco concrete and large metal objects can reduce the range Place the transmitter at least 6 feet in the air to improve signal transmission Place both units in their desired location and wait approximately 1 hour before permanently mounting the transmitter to ensure that there is proper reception The outdoor temperature humidity transmitter is water resis
13. go down it means the air pressure has dropped and the weather is expected to get worse from the present time 0h Note The bar graph will scroll continually to prevent LCD burnout WEATHER FORECAST ICONS Sun Slightly Cloudy Cloudy Rainy or Snow These icons forecast the weather in the next 12 24 hours The forecast icons displayed predict the weather in terms of getting better or worse and not necessarily sunny or rainy as each icon indicates SLIGHTLY CLOUDY CLOUDY NOTE After set up readings for weather forecasts should be disregarded for the next 48 60 hours This will allow sufficient time for the forecast station to collect air pressure data at a constant altitude and therefore result in a more accurate forecast WEATHER TENDENCY INDICATOR Up or Down arrows Working together with the weather icons is the Weather Tendency Indicators When the Indicator Points Upwards it means that the Air 4 pressure is increasing and the weather is expected to improve but when Indicator Points Downwards the Air pressure is falling and the weather is expected to become worse An arrow to the right means no change gt 83 F 63 F 83 F 43 F 63 F lt 43 F CLOTHING INDEX Fisherman The Fisherman Clothing change combinations are based on Outdoor Temperature from the transmitter on channel 1 only The Fisherman represents CURRENT TRENDS in Temperature MIN MAX The forecast station will show the daily minimum and maximum temperatur
14. hannel 1 Insert 2 fresh AA batteries into the transmitter observing the correct polarity see Install Batteries in the Outdoor Transmitter Note The CH switch is set to Channel 1 by default Confirm channel 1 is selected Keep the transmitter 5 10 feet from the Forecast station for 15 minutes to establish a good connection Within 3 minutes the station will beep and the outdoor temperature should be shown on the Forecast station If the outdoor temperature does not show after 3 minutes remove power from the transmitter and the Forecast station for 60 seconds and start again from step 1 If the outdoor temperature does not show up after a second attempt please slide open the battery cover of the outdoor transmitter to reveal the TX button Push down on the TX button for 3 seconds to send a wireless signal to the Forecast Station 6 Hold the CH button on the forecast station to start the search for the transmitter signal 7 For optimum 433 MHz transmission the outdoor transmitter should be placed a distance of no more than 200 feet 60 meters open air from the Forecast station Do Not Mix Old and New Batteries Do Not Mix Alkaline Standard Lithium or Rechargeable Batteries WWVB RADIO CONTROLLED TIME The NIST radio station WWVB is located in Ft Collins and transmits the exact time signal continuously throughout the United States at 60 kHz The signal can be received up to 2 000 miles away through the internal antenna in the
15. hannel 1 and insert 2 AA batteries Set the second outdoor transmitter to Channel 2 and insert 2 AA batteries Set the third outdoor transmitter to Channel 3 and insert 2 AA batteries Press and hold CH button on the Forecast station for 5 seconds The Forecast station will search for all outdoor transmitters Press the TX button on the back of each outdoor transmitter to transmit RF signal When RF connection is established the respective temperature amp humidity for each of the selected channels will appear on the main unit Allow the transmitters and the Forecast station to stay 5 10 feet apart for 15 minutes to establish a solid connection Install the battery covers on each sensor 10 After 15 minutes place the remote transmitters in appropriate locations see position the outdoor transmitter Press and release the CH button to view channel 1 2 or 3 on the Forecast station when multiple transmitters are used Note You cannot change channels if only one transmitter is connected CHANNEL SCROLL Press and release the CH button until you see O appear in the outdoor data area The Forecast station will automatically rotate through the channels for all connected transmitters Press and release the CH button to lock the Forecast station into one channel Then view channels individually with a press of the CH button OTHER FORECAST STATION ICONS A WWVB Reception icon a The tower icon will show solid when the Forecast stati
16. he year between year 2010 2039 Press the SET button again to confirm and to enter the month setting The month will flash Press and release the or button to set the month Press the SET button again to confirm and enter the date setting The date will flash Press and release the or button to set the date Confirm all calendar settings with the SET button to confirm and exit the program menu Note If no buttons are pressed for 20 seconds set mode will time out and return to live display mode reflecting whatever adjustments were made before it timed out Note Press the or button once to adjust by 1 unit or hold for fast scroll adjustment CITY SELECTION SUNRISE SUNSET TIMES Note Preset City abbreviations are at the end of this guide Choose the city closest to you in a north south direction This will provide the most accurate sunrise sunset times aul f TIDE G a f mo MOON Er PHASE a Lore UT To select a city location Select your country state and then city location Hold the CITY button for 5 seconds USA USA will flash next to the sunrise sunset time Press and release the or button to select USA CAN or MEX as your country Press the CITY button to confirm the country and select a state Note When either Canada or Mexico is chosen you will move directly to city selection The state will flash Press and release the or button to select a state Press the CITY button to confir
17. hen operating on a c power the backlight and USB charge port will turn off while the Forecast station searches for the WWVB signal to avoid interference Both features will return after the 2 10 minute search which occurs during the late night or early morning hours Note In case the Forecast station is not able to detect the WWVB signal disturbances transmitting distance etc the time may be manually set WWVB Manual Signal Search Normal mode Hold the and buttons together for 3 seconds to enter manual search Reception mode Hold the and buttons together for 3 seconds to exit searching for the WWVB signal Note In case the Wireless Forecast Station is not able to detect the WWVB signal disturbances transmitting distance etc the time can be manually set by following the program menu Recommended distance to any interfering sources like computer monitors or TV sets is a minimum of 6 feet 2 meters Within ferro concrete rooms basements superstructures the received signal is naturally weakened In extreme cases please place the unit close to a window and or point its front or back towards the Fort Collins Colorado transmitter During nighttime the atmospheric disturbances are usually less severe and reception is possible in most cases A single daily reception is adequate to keep the accuracy deviation below 1 second Note In case the Forecast station is not able to detect the WWVB signal disturbances transmit
18. indicates which alarm is active DEACTIVATE Press and release the ALARM button to enter the correct Alarm mode Press and release the button and the alarm icon s will disappear indicating alarm 1 and or alarm 2 is off on pa Fon by swt 056 SET TIME ALARM 2 Press and release the ALARM button twice to enter Alarm mode The Alarm Time and A2 will show Follow steps 1 4 above to program alarm 2 SNOOZE When either alarm 1 or alarm 2 sounds press the SNOOZE LIGHT button on the top of the forecast station once to activate the snooze feature for 10 minutes The alarm icon 4 and the snooze icon ZZ will flash when the snooze is active Press any button to deactivate the snooze feature FROST ALARM ie The Frost Alarm when active will sound when the outdoor temperature drops to 34 F 1 1 C 1 ACTIVATE Press and release the TEMP ALERT button to activate the Frost Alarm on all channels when multiple transmitters in use The Frost Alarm icon will appear in the outdoor temperature area when active DEACTIVATE Press and release the TEMP ALERT button until the Frost Alarm icon no longer shows OUTDOOR TEMPERATURE ALARMS A high and low outdoor temperature alarm may be set on the forecast station Note When multiple transmitters are connected on different channels a high and or low temperature may be set for each channel SET TEMPERATURE ALARM CHANNEL 1 1 Press and release the CH button to select channel 1 when multiple trans
19. is lit For instance the moon will be blank during a new moon and dark during a full moon O99900 New Moon SmallWaxing Large Waxing First Quarter Small Waxing Large Waxing Crescent Crescent Gibbous Gibbous CEDE DE DKO Full Moon Large Waning Small Waning Last Quarter Large Waning Small Waning Gibbous Gibbous Crescent Crescent New Moon occurs when the moon is between the earth and sun so the illuminated portion of the moon is on the back side facing the sun and we cannot see it After a new moon the illuminated visible portion will increase or wax until the full moon occurs Full Moon occurs when the earth moon and sun are in approximate alignment with the moon and the sun on opposite sides of the earth The illuminated portion of the moon faces the earth giving us complete visibility of one side of the entire moon After a full moon the illuminated portion will decrease or wane until the new moon occurs First Quarter and Last Quarter moons occur when the moon is at a 90 degree angle to the earth and sun So we see half of the moon illuminated and half is in shadow Waxing means growing or expanding illumination and happens after a new moon Waning means decreasing illumination and occurs after a full moon Crescent refers to the moon being less than half illuminated Crescents can be waning or waxing Gibbous describes a moon phase when more than half is illuminated Gibbous can be waxing or waning COMFORT STATEMENT The com
20. m the state and select a city 8 The city location will flash 9 Press and release the or button to select a city from the list at the end of this ANC manual 10 Press the CITY button to confirm and exit After a short calculation time the forecast station shows the times for sunrise and sunset moon phase and lunar tide Note When DST is in affect the forecast station will need to receive the WWVB time signal to make the adjustment for DST The WWYVVB signal includes an embedded bit to tell the station to adjust for DST Until that signal is received the first time the sunrise sunset times will be one hour off TIDE The tides reflected on this station are based on the ebb and neap tides of the lunar month Not daily high and low tides When the forecast station states high tide the tides will be higher than usual etc When the sun moon and earth are lined up at new and full phases of the moon tides will be higher When the moon is at right angles to the sun and Earth at the first and last quarter the tides are weaker Full amp new moon spring tide TIDE HI Quarter neap tide TIDE LO Other mean water level TIDE MID MOON PHASE The LCD Moon phase is divided by 6 sections showing a total of 12 phases of the moon Note With the moon shown against a light colored background the phases will show opposite to a paper calendar The segments that are highlighted portray the part of the moon that
21. mitters in use 2 Hold the TEMP ALERT button until the High Temp Alert icon Aent appears and the temperature will flash Use the or button to select your High Temp alarm value Press and release the SET button to move to the Low Temp alarm The Low Temp Alert icon will appear and the temperature will flash Use the or button to select your Low Temp alarm value Press and release the SET button to confirm and exit to current temperature rene The Temp Alert icon will show in the outdoor temperature area when a temperature alarm is active When the temperature alarm sounds the Temp Alert icon E and the temperature value will flash Press any button to silence the alarm temporarily SET TEMPERATURE ALARM CHANNEL 2 or 3 Use the CH button to select the channel Follow steps 2 4 above to set temperature alarms on other channels DEACTIVATE TEMPERATURE ALARM Press and release the TEMP ALERT button 3 times to deactivate all temperature alarms The alert icons will disappear o TEMPERATURE TREND ICONS The indoor and outdoor temperature trend indicators will update every 30 minutes or less These trends represent temperature changes over the past three hours gt Temperature rising more than 2 F 1 C in the past three hours Temperature has not changed more than 2 F 1 C in the past three hours Temperature falling more than 2 F 1 C in the past three hours The temperature trend indicators ar
22. n related circumstances LA CROSSE TECHNOLOGY LTD WILL NOT ASSUME LIABILITY FOR INCIDENTAL CONSEQUENTIAL PUNITIVE OR OTHER SIMILAR DAMAGES ASSOCIATED WITH THE OPERATION OR MALFUNCTION OF THIS PRODUCT THIS PRODUCT IS NOT TO BE USED FOR MEDICAL PURPOSES OR FOR PUBLIC INFORMATION THIS PRODUCT IS NOT A TOY KEEP OUT OF CHILDREN S REACH This warranty gives you specific legal rights You may also have other rights specific to the State Some States do not allow the exclusion of consequential or incidental damages therefore the above exclusion of limitation may not apply to you For warranty work technical support or information contact La Crosse Technology Ltd 2817 Losey Blvd S La Crosse WI 54601 Contact Support 1 608 782 1610 Product Registration www lacrossetechnology com support register The complete instruction manual is available at www lacrossetechnology com 308 1451 Protected under U S Patents 5 978 738 6 076 044 6 597 990 FCC DISCLAIMER This Device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 the device must accept any interference received including interference that may cause undesired operation NOTE THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT SUCH MODIFICATIONS COULD VOID THE USER AUTHORITY TO OPERATE THE EQUI
23. nd New Batteries Do Not Mix Alkaline Lithium Standard or Rechargeable Batteries If the Forecast station does not display indoor temperature after 60 seconds remove batteries and wait for at least 60 seconds before repeating the setup process INSTALL BATTERIES IN THE OUTDOOR TRANSMITTER Slide the battery cover down then lift off the back of the transmitter Note Be careful not to break the tabs on the battery cover Confirm the channel selector switch is on channel 1 Insert two fresh AA batteries into the transmitter Observe the correct polarity see marking inside battery compartment Keep transmitter 5 10 ft from the forecast station during setup After 15 minutes if the outdoor temperature shows on the forecast station move the outdoor transmitter outside to a shaded location within range of the forecast station CARE AND MAINTENANCE Do Not Mix Old and New Batteries Do Not Mix Alkaline Lithium Standard or Rechargeable Batteries Do not expose the Forecast station to extreme temperatures vibration or shock Keep dry Clean Forecast station with a soft damp cloth Do not use solvents or scouring agents The Forecast station is not a toy Keep it out of reach of children The Forecast station is not to be used for medical purpose or for public information but is determined for home use only The specifications of this Forecast station may change without prior notice Improper use or unauthorized opening of housin
24. on has received the WWVB signal No tower icon displayed The Forecast station was unable to receive a signal at this time Reposition the Forecast station for better signal reception or try again at bedtime IN Indoor readings Temperature Humidity Dew Point Heat Index Outdoor Channel indicator The number 1 2 or 3 for will appear next to this icon indicating which transmitter the Forecast station is reading Press and release the CH button to view other cH channels when using multiple sensors When this appears the outdoor temperature humidity readings will automatically switch between channels when using multiple sensors Press and release the CH button to display only one channel Zz Snooze icon a Will flash when snooze feature has been activated Solid when alarm is on Does not display when alarm is deactivated Alarm icon Shows when time alarm is on Does not display when time alarm is deactivated High Temperature Alarm active TEMP ALERT TEMP n aenar Low Temperature Alarm active Tomer E High and Low Temperature Alarms Active siie Frost Alarm active ants ms Sunrise time Sunset time om ofr on Humidity Low Battery lINSTALL BATTERIES IN THE FORECAST STATION Battery Compartment Batteries 1 Remove battery cover Slide tab to the right and pull out to remove battery cover 2 Install three fresh AA batteries according to the polarity markings Do Not Mix Old a
25. rands Dimensions Wireless Forecast Station TX14TH Transmitter 5 12 L x 2 36 W x 5 12 H 130 x 60 x 130 mm 2 5 Lx 1 42 W x 3 98 H 64 x 36 x 101 mm ACCURACY Indoor Temperature Operating temperature range 32 F to 122 F 0C to 50C Accuracy 2 degrees Fahrenheit 32 F to 122 F OC to 50C Resolution 0 1 degree F When above 122 F 50C the temperature sensor should continue to read the correct temperature as long as the LCD display continues to function When below 32 F 0C the temperature sensor should continue to read correctly as long as the LCD display continues to function Indoor Humidity Operating humidity range 1 RH to 99 e Accuracy 5 RH 25 C 30 RH to 80 RH Accuracy 8 RH 25 C 20 RH to29 RH 80 RH to 95 RH Accuracy 12 RH 25 C 1 RH to 19 RH 96 RH to 99 RH Resolution 1 RH Outdoor Temperature Operating temperature range 40 F to 140F 40C to 60C Accuracy 2 degrees Fahrenheit 32 F to 122 F OC to 50C Accuracy 4 degrees Fahrenheit 40 F to32 F 40C to OC 122 F t0140 F 50C to 60C Resolution 1 degree F Outdoor Humidity Operating humidity range 1 RH to 99 Accuracy 5 RH 25 C 20 RH to 90 RH Accuracy 8 RH 25 C 20 RH to 30 RH 80 RH to 95 RH Accuracy 12 RH 25 C 1 RH to 19 RH 96 RH to 99 RH Resolution 1 RH Barometric Pressure Measure range 800mb to 1
26. tant not waterproof and should not be placed anywhere it will become submerged in water or subject to standing water or snow POSITION THE FORECAST STATION 1 The Forecast station has a wide base to sit on a desk or table 2 Choose a location 6 feet or more from electronics such as cordless phones gaming systems televisions microwaves routers etc 3 Place within range of the outdoor transmitter The maximum transmitting range in open air is 200 feet 60 meters Obstacles such as walls windows stucco concrete and large metal objects can reduce the range For best WWVB reception orientate the Forecast station with the front of the back facing Ft Collins Colorado SPECIFICATIONS Indoor Temperature Range 32 F to 122 F 0 C to 50 C Humidity Range 1 99 RH Interval About every 30 seconds Barometric Pressure 23 62 to 32 48 inHg 800mb to 1100mb Interval About every 12 minutes Outdoor Temperature Range 40 F to 140 F 40 C to 60 C Humidity Range 1 99 RH Distance Over 200 ft 60 meters RF 433MHz open air Interval About every 50 seconds Power Wireless Forecast Station 3 AA IEC LR6 batteries not included TX14TH Transmitter 2 AA IEC LR6 batteries not included Battery Life TX14TH Transmitter Battery Life Battery life is over 24 months when using reputable battery brands Wireless Forecast Station Battery Life Battery life is over 12 months when using reputable battery b
27. ting distance etc the time and date can be manually set see program menu FUNCTION BUTTONS ALARM _ CH HISTORY CITY OQODIDNOAOO SET MAX MIN TEMP ALERT PROGRAM MENU The SET button will moves through the items in the program menu The or button will change these values WWYVEB reception ON or OFF Time Zone Seven Time Zones Daylight Saving Indicator 12 24 hour time format Fahrenheit Celsius selection Manual time set Hour Minutes Seconds Calendar set Year Month Date WWVB RECEPTION The WWVB time reception defaults to ON To turn the WWVEB reception OFF Hold the SET button for 5 seconds WWV6B and ON will flash in the time display Press and release the or button to turn this OFF Confirm with the SET button and move to the Time Zone TIME ZONE This station offers seven time zones listed in letter format default is EST AST Atlantic Time EST Eastern Time CST Central Time MST Mountain Time TIMEZONE PST Pacific Time AKT Alaskan Time EST HAT Hawaiian Time EST will flash next to the date Press and release the or button to select a different Time Zone Confirm with the SET button and move to Daylight Saving Indicator DAYLIGHT SAVING INDICATOR DST will default to the ON position as most of the country observes the DST change If you live in an area does not observe the DST change switch this to the OFF position 1 DST and ON will fl
Download Pdf Manuals
Related Search
Related Contents
Monitor LCD serie VW199 Guida dell`utente KISS Pro Manual Kiss Pro Manual Rieber Thermoport Copyright © All rights reserved.