Home
User`s manual, control centre CCP Alpha
Contents
1. 4 6 PoC ENTRELECC 3 1 3 TERMINAL M4 6 2 8 101 108 TERMINAL M4 6 PE ENTRELEC 4 SWITCH 5 1 40 2 O ee 2 SKINTOP_ST16 22 5 1 4 CABLE INLET 5 5716 18 6 AHLSELL Order nr Blad nr CCP ALPHA 9514 1 a ab Control unit Lubrication pump ee ATVIDABERG swepen Artnr 907179 9514 03 46 0 120 299 90 Layout Parts list 5 220 50 60 2 10 5 HIGHEST 0 022 KABLE COLOUR 11 13 Berack NEUTRAL N LIGHT BLUE GROUND GREEN YELLOW 230v man _MAN BLACK L 230V BLUE 0 75 7 24Vac GcolwHiTeE LUBRICATION PUMP 24Vdc DARK BLUE EXT ORANGE LUBRICATION PUMP INDIKERING LUBRICATION PUMP ALARM LUBRICATION PUMP MACHINE STOP LOW LEVEL LUBRICATION SPARE AUTOMATIC LUBRICATION PUMP LOW LEVEL LUBRICATION LOW LEVEL LUBRICATION CCP ALPHA Oooo Control unit Lubrication pump A avtomatik ab _ frit 907178 060626 46 20 299 90 Control diagram nr 9514 03 5 462 5 5 461 5 LOW LUBRICATION LEVEL ALARM LOW LUBRICATION LEV gt Q a 5 z gt 2 a lt 0 gt ALPHA avtomatik ab Control unit Lubrication pump een Artnr 907
2. pump is controlled by the setting for pump time and pause time SETTINGS The time the lubrication shall continue here called pump time and the time between the lubrications here called pause time can be set To be able to change the setting put the switch MITSUBISHI for type of running in the 0 position PUMP TIME Place the cursor at the setting to be changed 10 min with the up down arrow PAUSE TIME 60 min Change setting by pressing or Confirm the new setting by pressing OK NORMAL RUNNING During the pause time it is shown how much that has passed of the pause time J MITSUBISHI TIME PAUS 11 min PAUSE TIME 60 min In this example 11 minuter has passed of the pause time During the pump time it is shown how much that has passed of the pump time J MITSUBISHI PUMP TIME In this example 4 minuter has passed of the 10 min pump time TIME PUMP 4 min ASSALUB AB Box 240 S 597 26 ATVIDABERG SWEDEN Tel 46 120 358 40 Fax 46 120 152 11 E post info assalub se www assalub se 3 CONTINOUS LUBRICATION When the switch for type of running is in 1 position the pump runs continously Aa MITSUBISHI CONT LUBR MACHINE INTERLOCKING The control centre can be controlled by the lubricated machine so called machine interlocking Aa MITSUBISHI When the contact for machine interlocking is being closed the lubricated machine is stopped the lubrication phase in progress if any
3. 12132 06 06 CONTROL CENTRE CCP Alpha Art No 907179 USER S MANUAL CONTENTS 1 DESCRIPTION Page 2 2 DATA Page 2 3 HANDLING Page 3 4 ELECTRIC DIAGRAM Page 6 5 CE Certificate Annex 1 ASSALUB AB Box 240 S 597 26 ATVIDABERG SWEDEN Tel 46 120 358 40 Fax 46 120 152 11 E post info assalub se www assalub se 1 1 DESCRIPTION The control centre CCP Alpha controls and monitorse one electric motor powered lubrication pump One low level switch can be monitored FUNCTIONS Adjustable pause and pump time Continuously pumping Machine interlocking control Output for alarm signal activated at low level of lubricant reservoir or triggered motor protection switch DEFINITIONS Pause time Time from pump stop to pump start Pump time Time from pump start to pump stop 2 DATA Protection class IP 65 Dimensions 230x300x145 WxHxD Weight 4 5 kg Supply voltage 3x220V 50 60 Hz Current max 10A Outputs Pump 3x220 V 0 75A Alarm Potential free contact max 250V AC 30V DC Max 1A Inputs 24V DC Adjustment range Pause time 1 32 767 minutes Pause time 1 32 767 minutes ASSALUB AB Box 240 S 597 26 ATVIDABERG SWEDEN Tel 46 120 358 40 Fax 46 120 152 11 E post info assalub se www assalub se 2 3 HANDLING TYPE OF RUNNING With the switch in the front of the cabinet the type of running is choosen 1 The pump is running continously 0 The pump is stopped Aut The
4. 179 9514 03 46 0 120 299 90 Connecting diagram
5. is stopped as well as the time counting At restart of the machine the lubrication phase and the time counting resumes ALARM If the alarm level switch in the lubricant reservoir is triggered a low level alarm is activated J MITSUBISHI LOW LEVEL The system stops lubricating and the alarm contact closes The alarm is deactivated when the reservoir has been replenished ASSALUB AB Box 240 S 597 26 ATVIDABERG SWEDEN Tel 46 120 358 40 Fax 46 120 152 11 E post info assalub se www assalub se 4 If the motor protection switch is triggered a pump alarm is activated J MITSUBISHI PUMP The system stops lubricating and the alarm ALARM contact closes The alarm is deactivated when the motor protection switch is reset ASSALUB AB Box 240 S 597 26 ATVIDABERG SWEDEN Tel 46 120 358 40 Fax 46 120 152 11 E post info assalub se www assalub se 5 TERMINALS D 180 11 CAB PC3020 18T bygel EKIV 23 200x300x180 FIBOX a ee 1 s1 SWITCH ZB4 BK1353 ZB4 BW0B51 ZBE 101 24 YELLOW 3CL_3 POS GROUPE SCHNEIDER 1 THI LAMP ZB4 BVB4 24V RED GROUPE SCHNEIDER 1 k CONTACTOR WITH TERMAL RELAY LC1DO9P7 LRDO5 0 63 1A_ GROUPE SCHNEIDER 1 F MCCB 243 33 2 POL_C3A GROUPE SCHNEIDER aa eee SSS E 1 Pre Ci AL 1 0MR D PoC MITSUBISHI ar eee nr eee 1 1 m1 POWER SUPPLY CMP 230 24 230 24V 30VA MEANWELL Sa S221 OEE 2 PE
Download Pdf Manuals
Related Search
Related Contents
Manuale di istruzioni User Manual Pulsar 429 - User Manual & Certificates ET-A-EQ-11 OPERAÇÃO DO INCINERADOR Copyright © All rights reserved.
Failed to retrieve file