Home
bipower 7000
Contents
1. pag 4 13 General information 5 2 AIR CONDITIONER IDENTIFICATION TTL pag 6 21 Compornernls rm pag 6 22 DB pag 6 2 3 Technical features 44 4144 pag 7 2 4 Connection diagram pag 7 3 TRANSPORT HANDLING STORAGE Teen eT pag 8 31 I a pag 8 32 Won eee pag 8 20816 eee pag 8 4 INSTALLATION ere nn pag 8 4 1 Preliminary information pag 8 4 2 Installation pag 8 4 3 Installing the condenser unit pag 9 4 3 1 A type installation emen nnn nnn nnn eem pag 9 4 3 2 type installation nnn nnn 14414414 pag 9 4 4 Howto fasten the condenser unit pag 13 5 INSTALLING THE EVAPORATING AERATOR UNIT pag 14 5 1 Using the ventilation por
2. type installation The condenser unit sucks in the outside air from the side and drives the hot air out towards the bottom 4 3 2 type installation The condenser unit sucks in the outside air from the bottom and drives the hot air out towards the bottom too This kind of installation calls for greater attention since it is of the utmost importance that the hot air which is driven out is not sucked back in via the opening Fig 3 Ref 1 as this would diminish the efficiency of the conditioner Should the condenser unit be installed outside the vehicle do not place the air inlet hole against a wall which could limit the passage of air If the unit is too close to the ground less than 40 cm the hot air driven out from Fig 3 Ref 2 as it springs back from the ground could be sucked in again by the opening Fig 3 Ref 1 A type installation 1 Outside cool air inlet 2 Hot air outlet B type installation Flair If you install the condenser unit inside the vehicle you must be careful to keep the flow of the sucked in outside air separate from that of the hot air driven out and also prevent the expelled hot air from getting inside the vehicle To separate the two air flows use a soft sponge adhesive liner Fig 4 Ref 3 placing it against the floor in order to prevent the hot air coming out from Fig 4 Ref 2 from being sucked in through the op
3. AIR CONDITIONER Split BIPOWER 1000 MANUAL FOR INSTALLATION AND USER MANUAL GE V001 June 2005 ET SPLIT BIPOWER 7000 Via E Majorana 49 48022 Lugo RA ITALY CE STATEMENT OF COMPLIANCE Under the EEC Machine Directive 89 392 attachment IIA We hereby declare that the air conditioner the data of which are provided below has been designed and built to comply with the essential requirements in terms of safety and health laid down by the European Directive on Machine Safety This statement shall fail to be valid should any changes be made to the machine without our approval in writing Machine AIR CONDITIONER Model SPLIT BIPOWER 7000 Serial Number Directive of reference Machine Directive 89 392 EEC in the 91 31 EEC version Low Voltage Directive 73 23 EEC Electromagnetic compatibility 89 336 EEC in the 93 31 EEC version Harmonized standards applied especially EN 292 1 EN 292 2 EN 60204 1 DATE January 2004 THE CHAIRMAN 90 Manual drawn up in the Flair technical office SPLIT BIPOWER 7000 INDEX FOREWORD err ure nnn Tree e LLL Tee uL nnn nn nnennnneennnns pag 4 i Purpose and scope of application of this manual pag 4 1 2 Symbols and definitions
4. PAC ANN SU agg YN 18 1 ZHOS NL AO C Scc az TANVd puer 1005 x AV I38 JOSSIYAMNOO LAVLS AVE JONVISIS3M LH 390148 30010 Add YOSNAS 1YNSSIAd LHOIH XWd YOLOW ONILVEOdVAS SAW YOLOW 9NISN3QNOO JAN AV T3 99 AV I38 I3A MOT CAM AVT38 TSA LAM 133818 LAN S85 AV I38 dlNOO M 3Sf14 A4311V4 95 4504 Xn 023 AAW 3Sf3 93 3503 93 YASNACNOO YVIO WO ANON QNOO 39 YASNAGNOO YALYVLS VO X3QNI JAN FYOLVYOd VAT VINOS LIS 6 SPLIT BIPOWER 7000 WRENCH KIT LIST FOR ASSEMBLING SPLIT CONDITIONERS Open 24 wrench Open 22 wrench Open 19 wrench T 3 1 Tightening fastening vibration dampers Tightening self tapping screws for Screwdriver condenser conveyor 10 wrench i Screwdriver Open 13 wrench The same key can be used for all the nuts and bolts for closing the plates condenser 8 wrench Assembling brackets on condenser u SPLIT 7000 GENERAL TERMS OF WARRANTY Telair guarantees that its products are without faults or defects in their material and or construction The effects of the warranty are understood to be limited to the right to obtain replacement or repair free of cost of any part which should turn out to
5. and use This manual lays down the purpose for which the machine was built and contains all the information needed to ensure its safe and proper use Constant compliance with the instructions contained in it ensure the safety of the user economy of use and longer machine life In order to make it easier to consult it has been subdivided into sections which identify the main ideas to consult it quickly refer to the table of contents The parts of the text which must not be ignored are highlighted in bold type and preceded by symbols which are explained below We strongly suggest reading the contents of this manual and of the documents of reference carefully this is the only way to ensure proper operation of the air conditioner through time its reliability and the prevention of any damage to people or things Note the information provided here was correct at the time of going to press but may be modified at any time without prior notice SPLIT BIPOWER 7000 1 2 Symbols and definitions DANGER This means you must be careful to avoid serious consequences which could lead to the death or injury of people N WARNING This means a situation which could take place within the lifetime of a product system or installation considered to be hazardous in terms of injury to people damage to property or to the environment or financial loss CAUTION This means you must pay attention in order to incur serio
6. be defective within 12 months from the date of purchase of the product and in Telairs opinion It is understood that the purchaser has no right whatsoever to terminate the contract toclaim damages for people or things todemand an extension of the warranty in case of any product defect or malfunction Any transport charges are on the account of the purchaser as well as any expenses for on site checks requested by the purchaser and accepted by Telair The warranty shall be valid only if the customer is able to show a document evidencing the date of purchase invoice or receipt This document must be kept whole and must be submitted to the Telair after sales centre when asking for operation under warranty SPLIT BIPOWER 7000 SPLIT BIPOWER 7000 SPLIT BIPOWER 7000 Foto e disegni non contrattuali Les photos et les dessins ne sont donn s qu a titre indicatif We reserve the right to make technical changes without prior notice Fotos und Zeichnungen nicht vertraglich Fotos y planos no indicados en contrato IN EUROPE GREAT BRITAIN SCAN TERIEUR LTD 30 The Metro Centre Tolpits Lane Watford Herts England WD18 9XG Tel 01923 800353 Fax 01923 220358 HOLLAND KARMAN AGENTUREN Emmastraat 31 ITALY l 1213 AJ Hilversum Holland Via E Majorana 49 Tel 035 6240156 Fax 035 6242141 48022 LUGO RA e mail karman agenturen worldonline nl Tel 39 0545 25037 FRANCE
7. mm thick If you crush the liner too much this will damage the supporting base of the air conditioner compromising the sealing of the joint and generating loud noise inside the vehicle when working TE Telair SPLIT BIPOWER 7000 5 4 Installing the diffuser After anchoring the evaporating unit to the roof of the vehicle take both cold air outlet flaps out of the diffuser Fig 16 Fit the probe of the thermometer into the rubber tab on one side of the aluminium conveyor Fig 17 Ref 3 Connect the cable 1 coming from the condensing unit to the connector of the control unit then the cable 2 red black coming from the evaporator to the other cable on the control unit SPLIT BIPOWER 7000 Apply the diffuser to the conveyor Make sure that the aluminium tunnel is properly placed at the very centre of the diffuser Fasten the diffuser to the ceiling using the self tapping screws provided with the supply Fig 18 Put the two cold air direction orientation flaps back on Fig 19 6 USER INSTRUCTIONS 6 1 Foreword The SPLIT BIPOWER 7000 air conditioner consists of four basic sections e compressor this makes the refrigerating gas inside the system circulate and raises its temperature e condenser this cools the refrigerant changing its state from gaseous to liquid e injector this changes the state of the refrigerant from liquid to gaseous e evaporator this rec
8. BLEYS ANTOINE BLEYS JEAN PHILIPPE Fax 39 0545 32064 19 Rue de la Parcheminerie Tel 02 48580367 Fax 02 48583585 899 899 856 Mobil 06 78262186 Mobil 06 07012634 e mail bleysetd club internet fr jp bleysetd club internet fr ESPANA NAUCCA CARAVANING S A E mail telair telecogroup com Poligono Industrial CAN ROQUETA 2 Calle Can Lletget 2 www telecogroup com 08202 Sabadell Barcelona Espa a Tel 0937 457 054 Fax 0937 254 484 e mail comercial naucca com OSTERREICH TELECO GmbH 82041 Deisenhofen Tel 49 08031 98939 Fax 49 08031 98949 e mail telecogmbh telecogroup com www telecogroup com ry a m go LOB IN DEUTSHLAND xv TELECO GmbH SZ TELECO GmbH 82041 Deisenhofen Tel 08031 98939 Fax 08031 98949 e mail telecogmbh telecogroup com www telecogroup com Handler und Info in Ihrer Nahe 01805 006857 Service fur Teleco Anlagen in Deutschland 09001000690 KUNDENDIENST BEI AUSGEWAHLTEN BOSCH SERVICE
9. That the direct power supply is never less than 205 V or else that the battery has not run out e The suction filters are not jammed e The air diffusion outlets are open 1 The air conditioner fails to start up e make sure that the cool air warm air switch Fig 20 Ref 2 is not in 0 position and that the thermostat is in its all cool position Fig 20 Ref 3 e Then make sure that the sockets are powered connecting a household appliance or using a voltmeter 2 The compressor does not work e for the compressor to work the thermostat Fig 20 Ref 3 must be set at a temperature at least 5 degrees lower than that of the indoor environment of the vehicle and the warm cool selector must be in cool position 3 The evaporator fan does not work e make sure that the ON OFF switch Fig 20 Ref 2 is not in 0 position and that the fan speed selector Fig 20 Ref 1 is not blocked in an intermediate position 4 The condenser fan does not work e call in a technician SPLIT BIPOWER 7000 5 The air conditioner has a poor yield e if the air conditioner has a poor yield you must clean the air filter the condenser and the evaporator using specific detergents We suggest washing the air conditioner before using it after a long period of time during which it has not been used If the air conditioner does not recover its initial yield even after the exchangers have been cleaned check the load of the refrigera
10. d the ambient temperature TA inside the vehicle is displayed for a few seconds The display then reverts to the temperature setting In addition to temperature the Display fig 20 ref 5 also shows the following 4 AUT Speed1 Speed 2 Speed3 Automatic Speed WAY HEATING winter WAY COOLING summer SPLIT BIPOWER 7000 6 6 Setting fan speed T Press the speed key fig 20 rif 1 If pressed once the display shows the fan speed setting this is shown for a few seconds before the display reverts to ambient temperature TA To modify fan speed keep pressing the key fan speed will be adjusted according to the following sequence Fi Fi 213 ALT In which F11 F12 and F13 are the three fixed speeds and AUT is automatic speed F11 indicates slow fan speed F12 medium speed and F13 high speed If one of the three fixed speeds is set the control panel always activates ventilation at that same speed If instead fan speed is set to AUT the control panel step by step fig 20 automatically selects the most appropriate fan speed in consideration of the temperature setting and the temperature in the vehicle interior 6 7 Thermostat fig 20 rif 2 Hotate the thermostat to set the desired temperature on the display INFORMATION The control panel fig 20 allows automatic contro of temperature in the vehicle interior If for example we set a temperature of 25 C the condit
11. ditioner 6 10 Safety rules e Always use power sockets which are connected to earth and are protected by differential cut off switches e Never use the air conditioner near flammable liquids e Never use the air conditioner for any purpose other than those provided for by the Manufacturer e Do not modify or tamper with any part of the air conditioner e Use original spare parts e Maintenance and repairs must be carried out by specialized personnel e Do not put your hands inside the ventilation grids e Do not put any foreign matter into the ventilation outlets e Should the air conditioner suffer from any forceful impact have specialized technicians check it out before using it again e n case of fire never open the top lid of the air conditioner but use approved type fire extinguishers e Do not use water to put out fire SPLIT BIPOWER 7000 6 11 Troubleshooting If the air conditioner fails to work properly this usually will not be due to a fault but simply to improper use For example e The air conditioner is undersized compared to the volume of air to be conditioned e he walls of the vehicle are not sufficiently insulated e he doors are opened too frequently e here are too many people inside the vehicle e Voltage is too low Following is a list of troubles which may come up their reasons and how to solve them INFORMATION f the air conditioner is working poorly first make sure e
12. eives the refrigerant in its gaseous state cooling the surrounding air The cooled air is spread inside the vehicle by a variable speed fan The air temperature is controlled by a thermostat Before starting up the air conditioner after a long period during which the vehicle has been exposed to the sun it is good practice to open the doors and windows to let out the heat which has been accumulated inside When the temperature inside the vehicle has reached the same level as the outdoor temperature close the doors and windows and start up the air conditioning system opening the doors and windows only in case of need The SPLIT BIPOWER 7000 air conditioner is able to run at both 12 Volts battery and at 230 Volts power mains The 12 Volt or 230 Volt power supply is selected by a special circuit which when a mains voltage at 230 Volts is present cuts the connection to the 12 Volt battery off automatically and activates the connection to the power mains On the other hand when the plug is taken out of the 230 Volt power source the circuit automatically restores the connection to the 12 Volt battery if the conditioner is made to run at 12 Volts with the vehicle parked remember that a good 100 Ah battery completely charged will last for no more than one and a half hours If the battery is not in a good condition or is smaller this time will diminish drastically In any case we suggest you do NOT use the battery until it
13. ening Fig 4 Ref 1 After having prepared the area of installation of the condenser unit you should connect the gas pipes and the extension cables before finally fastening the unit in place The metal container has been set up so as to let both gas pipes the 2 extension cables and the 230 Volt feeding cable of the air conditioner out on 2 directions on the long side Fig 5 Ref 2 and on the short side Fig 5 Ref 3 SPLIT BIPOWER 7000 After having chosen the best position first take off the lid Fig 5 Ref A in order to access the inside of the condenser unit and then take off one of the other two lids Fig 5 Ref B if you have chosen the outlet on the long side Fig 5 Ref 2 Fig 5 Ref C if you chosen the outlet on the short side Fig 5 Ref 3 1 Outside cool air inlet 2 Hot air outlet 3 Soft adhesive sponge liner SPLIT BIPOWER 7000 Telair The extension cables and pipes are provided with Connect the extension cable to the relevant a through bush Fig 6 Ref 1 which must be fitted connector of the condenser unit Fig 7 Ref 1 into each of the sockets Fig 6 Ref 2 and then locked in place via the nut Fig 6 Ref 3 Connect both pipes of the refrigerating gas to the relevant quick couplings screwing all the way down using two wrenches Fig 7 Ref 2 and 3 Flair Fit the through bushes into the socket and lock them in
14. g 20 6 11 Troubl eshoolllig pag 20 7 MAINTENANCE nn pag 21 7 1 Maintenance operations pag 21 8 DISPOSAL err rre eru Tree eL TTL LLLTT LLLT T pag 21 WIRING DIAGRAM nenn pag 22 WRENCH KIT LIST FOR ASSEMBLING SPLIT CONDITIONERS pag 23 GENERAL TERMS OF WARRANTY re ener nere nen nnn nn nen nennennnnnnnennnnnen pag 24 1 FOREWORD LA MANUAL Read this manual carefully before carrying out any kind of operation on the air conditioner 1 1 Purpose and scope of application of this manual This manual has been drawn up by the Manufacturer in order to provide the essential information and instruction needed to carry out every maintenance and use operation on the air conditioner in a proper and safe manner It is an integral part of the equipment of the air conditioner and must be kept carefully throughout its lifetime and protected against any agent which might deteriorate it It must follow the air conditioner if this is reinstalled on another vehicle or if there is a change of property The information contained in this manual is addressed to the staff which must install the air conditioner and to all those involved in maintenance
15. ioner will produce cold air as long as the temperature inside the vehicle is higher than 25 C N WARNING Correct use of the thermostat is very important If you set a temperature much lower than outdoor temperature more than 8 C lower you run the risk of falling ill catching colds etc and energy consumption increases 6 8 Cooling mode 1 When this symbol is displayed constantly the air conditioner is generating cold air When the symbol flashes the air conditioner is restoring gas pressures inside its interior and will start producing cold air after 3 minutes When neither the symbol not the heating symbol appear this means that a a ambient temperature has reached the set temperature so the compressor is off and only the ventilation fans are working b temperature is less than 16 C and the thermostat is set to minimum In this case as long as ambient temperature remains below the 16 C threshold only the fans work the compressor is shut down 0 6 9 Switching off To switch the air conditioner off press the on off key fig 20 ref 3 CAUTION After turning off the air conditioner using the thermostat knob or else the ON OFF switch you must wait at least 3 minutes before turning it back on again in order to allow the refrigerant to stabilize its pressure Failure to comply with this rule may lead to irreparable damage to the compressor of the air con
16. is protected by a suitable carton packaging The air conditioner must be stored in a horizontal position in a covered dry and ventilated environment The package is made to allow up to five 5 condensing parts and up to five 5 evaporating parts to be stacked f CAUTION Do not turn the package upside down The right position is shown by the symbol stamped on the package 1 Stacking a larger number of items than the number specified above complete with their packaging is dangerous not only for the integrity of the equipment but is also hazardous for people 3 2 Weight Weight not including packaging SPLIT BIPOWER 7000 26 kg for the condensing part 9 kg for the evaporating part 3 3 Handling The air conditioners complete with their packaging can be handled using ordinary hoisting and transport means The boxes are fitted with spacers which allow you to introduce transpallet forks When hoisting and transporting comply with accident prevention and safety rules Use hoisting and transport equipment with a capacity greater than the load to be hoisted SPLIT BIPOWER 7000 4 INSTALLATION 4 1 Preliminary information INFORMATION Before installing the air conditioner you must by all means read these instructions in order not to make any mistake while installing i N WARNING Improper installation of the air conditioners may lead to irreparable damage to the equipment and compro
17. mise the safety of the user Should the air conditioners be installed in a manner which does not comply with the instructions of this manual the Manufacturer shall not be held liable for any failure or for the safety of the air conditioner according to the law DM 89 392 EEC The Manufacturer shall also not be liable in such a case for any damage to things or injury to people Installation must be performed only by qualified and properly trained staff 4 2 Installation i N WARNING Before installing you must cut off all the power supply to the vehicle e Battery positive pole e Generator unit if any e Outside power source DANGER comply with the above instructions may lead to electrical discharge DANGER Before getting onto the roof of the vehicle make sure it is strong enough to be walked on Check with the provider of the vehicle Should it not be strong enough you must set up a special trestle with scaffolding SPLIT BIPOWER 7000 4 3 Installing the condenser unit When you install the condenser unit remember it must always communicate towards the outside via at least two openings Fig 3 Ref 1 and 2 In fact the condenser unit sucks air in from the outside via the opening Fig 3 Ref 1 then after having used it to cool the condenser inside it again drives the heated air out via the opening Fig 3 Ref 2 Two kinds of installations can be made 4 3 1 A
18. n you connect the SPLIT BIPOWER air conditioner to a power source the battery disconnects automatically SPLIT Telair BIPOWER 7000 2 AIR CONDITIONER IDENTIFICATION 2 1 Components Fig 1 2 2 ID plate A 1 CONDENSER UNIT 1 Model B 4 SILENT BLOCKS 1 SUCTION CONVEYOR 3 Serial number D 1 EXTENSION 6 m TUBE D 6 mm 4 Compressor and fan consumption E 1 EXTENSION 6 m TUBE D 10 mm 5 Type and quantity of refrigerating gas F 1 EXTENSION CONTROL CABLE G 1 EVAPORATOR UNIT H 1 COLD AIR CONVEYOR 1 DIFFUSER WITH CONTROLS SPLIT BIPOWER 7000 2 CODE xxxxxx 5 3 Refrigerating yeld 1 85 kW Voltage 12 Vdc e 230 a c 50Hz Inlet Power 650 920 W 4 ne gr 450 R134A 5 8 0 15564 006040 7 SPLIT BIPOWER 7000 2 3 Technical features Refrigerating power SPLIT BIPOWER 7000 1 85 kW 6500 BTU Number of fan speeds 2 auto Feeding 12 VDC 230 V 50 Hz Consumption 54A 12V 4 0A 230 V Absorbed power 650 920 W Refrigerating gas R 134A Air supply 300 m h Diffuser height 7 cm 2 4 Connection diagram Fig 2 THERMOMETER CABLE CONTROL PANEL CABLE D 10 mm TUBE D 6 mm TUBE CONTROL CABLE CONTROL CABLE 230V Flair 3 TRANSPORT HANDLING STORAGE 3 1 Storage During transport the air conditioner
19. ng sealant around the edges of the opening Put the evaporating unit onto the roof of the vehicle and place it over the opening previously treated with the sealant Make sure that the side holes which are on the bottom Fig 13 Ref 1 face the driving direction of the vehicle while the rear holes Fig 13 Ref 2 face the rear of the vehicle The arrow on Fig 13 shows the driving direction of the vehicle Telair INFORMATION Place the outside unit the roof as shown on the figure and centre it over the 39 5 x 39 5 cm hole Connect the cable coming from the condensing unit to the relevant cable on the control panel Connect both hoses screwing the two quick couplings all the way down using a wrench First connect the smaller tube 6 mm Fig 14 Ref 3 then the larger one 10 mm Fig 14 Ref 4 Cover the large tube and the coupling with anti condensation material Flair Introduce the aluminium air conveyor Fig 15 Ref 1 into the plastic tube of the evaporator and push it down until the 2 fastening brackets Fig 15 Ref 2 to the roof of the vehicle leading the 4 fastening screws out of the holes Fig 15 Ref 3 Note he air conveyor has been designed to be installed on vehicles with a roof having a thickness between 30 and 60 mm With thicker roofs one can ask for a suitable conveyor Do not crush the sealing liner too much it must not be less than 12
20. ort This solution can be applied on condition that the porthole measures 395x395 mm First remove the porthole after having taken out the screws which fasten it to the roof of the vehicle Scrape away all the sealing material located around the opening Fig 10 Ref 1 and suitable close the holes of the screws and the joint lines using silicone or putty of a kind easily available in specialized shops Fig 10 Ref 2 INFORMATION Every kind of scrap glue silicon liners and so on should not be disposed of within the environment but should be put in special containers and delivered to Collection and Disposal Centres SPLIT BIPOWER 7000 5 2 Opening a new hole On the roof chose an central area between two stanchions and use a felt pen to mark off a square measuring 395 mm on each side Fig 11 Ref 1 Use a small saw to carefully cut the opening on the roof Be careful not to cut any electric wires Fig 10 Ref 2 ZA CAUTION Wear goggles and safety gloves before using any electrical tools or manual saws SPLIT BIPOWER 7000 Place a reinforcing frame Fig 12 along the profile of the opening if necessary drill a hole on the side to let through the power cables and refrigerating gas pipes a 5 3 Positioning the evaporating unit Before positioning the evaporating unit on the roof of the vehicle you must spread a proper amount of slow dryi
21. place using the plastic nuts provided with the supply Let the 230 Volt supply cable out locking the through bush in place on the steel plate socket Fig 8 Ref 7 Put the lids back on fastening them carefully Fig 8 Ref 6 SPLIT BIPOWER 7000 Insert the red and black 12 Volt feeder cables Fig 8 Ref 4 and 5 into the two through bushes and fasten them on the connector provided with the equipment Now collect the connector to the inside one SPLIT BIPOWER 7000 4 4 How to fasten the condenser unit The condenser unit may be installed either suspended on two brackets not provided with the Supply on the outside of the vehicle Fig 9 Ref 1 or resting on the floor on the inside Fig 9 Ref 2 Every conditioner comes provided with 4 L shaped brackets and 4 silent blocks Fig 9 Ref 3 In order to avoid transmitting any vibrations from the condenser unit to the floor it is important to fasten the unit onto the silent blocks Flair 5 INSTALLING THE EVAPORATING AERATOR UNIT The evaporator unit may be installed in either of two ways e using the ventilation holes ventilation portholes already present on the vehicle e opening a new hole 5 1 Using the ventilation p
22. runs out as this would damage it irreparably and make it unusable in the future 17 SPLIT Telair BIPOWER 7000 6 2 Preliminary checks 0 6 4 Switching on u To switch the air conditioner on press the on off Before switching on the air conditioner forthe very key 20 ref 3 and at the same time the first time display is active e Check that condensate drainage holes are unobstructed WARNING After switching on the e Check that power voltage and frequency are conditioner there is a 3 minute pause before N the previous selon the compressor is started and cold air outflow e Check that air flow through relative ducts and begins vents is unobstructed To ensure maximum efficiency always keep external ventilation grilles clear J INFORMATION The conditioner features an automatic thermostat with a minimum 6 3 Control panel fig 20 working temperature of 16 C 1 C Below this temperature the thermostat does Fan speed key fig 20 ref 1 enable the compressor this prevents ice Thermostat adjuster knob fig 20 ref 2 forming On off switch fig 20 ref 3 inside the unit Fans and the heating function Menu key fig 20 ref 4 remain enabled Display fig 20 ref 5 6 5 Display fig 20 rif 5 The display shows the temperature setting SET Temperature is set via the thermostat knob fig 20 ref 2 Press the menu key zc fig 20 rif 4 on the display an
23. t pag 14 5 2 Opening a new hole pag 14 5 3 Positioning the evaporating unit 7 mMMMMM pag 15 5 4 Installing the diffuser pag 16 6 USER INSTRUCTIONS Hmmm nennen pag 17 6 1 Foreword pag 17 6 2 Preliminary checks pag 18 6 3 Control panel nnn nana eoe nene oen pag 18 6 4 Switching on pag 18 6 5 or RE pag 18 6 6 pag 19 pag 19 6 8 Cooling mode pag 19 6 9 X Switching off emen eene erem nemen nn ncn nnn mM pag 19 6 10 Satelyruless sn pa
24. ting gas MAINTENANCE 7 1 Maintenance operations In order to ensure proper efficiency of the air conditioner once a year you must carry out a thorough cleaning of the condenser or have a technician carry it out Before accessing the air conditioner you must by all means disconnect the 230 V and 12 Volt power supply and wait for every part to cool down e lake off the outside lid and spray a specific detergent on the heat exchangers evaporator and condenser and rinse with water to remove all dirt e Make sure the condensate outlet holes on the evaporator are free Fig 13 Ref 1 and 2 e Make sure the sealing liners are in proper condition and that no water is leaking into the vehicle e Make sure that both active carbon filters Fig 21 Ref 1 on the diffuser inside the vehicle are in proper condition case it is good practice to replace them at least once a year e Make sure that the insulation of the power cables is intact and remove any trace of humidity e Make sure all the screws are tightly fastened e During winter storage in the garage we suggest you disconnect the air conditioner from the power source and from the battery 8 DISPOSAL To dispose of the air conditioner please refer to specialized shops INFORMATION The waste material must not be disposed of in the environment but dispatched to special Collection Centres 0002 Jsmodig 11145 VIdSLLVa
25. us consequences which could lead to damage to material goods such as resources or the product INFORMATION which is especially important This refers to information Drawings and photos are provided by way of example only Although the machine you actually have may differ from the illustration in this manual its safety and the information provided for are guaranteed The manufacturer in order to pursue a policy of constant development and updating of the product may make changes without giving prior notice SPLIT BIPOWER 7000 1 3 General information Every SPLIT LINE air conditioner consists of two separate units 1 CONDENSER UNIT which can be installed outside the vehicle inside the double bottom inside the garage or a bench or a cabinet The purpose of this unit is to drive out hot air 2 EVAPORATOR UNIT or AERATOR which must be installed on the roof of the vehicle in the place of a porthole 40 x 40 cm or else on an opening of the same size made on an area of your choice on the roof itself It has the purpose of cooling the air inside the vehicle ya Both units are connected to each other by two very thin hoses 6 and 10 mm The hoses are connected to the units by quick coupling joints which do not require any special tool Allthe SPLIT BIPOWER air conditioners have been designed for 230 Volt AC and 12 Volt DC feeding The 230 Volt feeder takes priority whe