User Manual - Zeta Alarm Systems

image

Contents

1. 2 x 2Ah Batteries 12V 2 Approved Document No GLT MAN 118 Issue 1 1 Author NRPJ Date 22 11 2006 PAGE 4 P E Elite INSTRUCTION MANUAL 1 2 ZONE FIRE ALARM PANEL Detectors amp sounders Wiring the detectors The Premier Elite has been designed to use a 10K resistor end of line on the detector zones Zone Zone Call points should be connected to the start of the zone so that removing a detector head will not remove power from the call points Also note that detector bases with a continuity diode will not be compatible with this panel The diode should be removed to allow detector head removal indicator to work Wiring the sounders The Premier Elite has 2 sounder circuits with a combined rating of 800mA Each sounder circuit must be fitted with a 10k end of line resistor SND SND SOUNDER SOUNDER SOUNDER SOUNDER 10K x xm x End of Line Resistor Approved Document No GLT MAN 118 PAGE 5 Issue 1 1 Author NRPJ Date 22 11 2006 Elst INSTRUCTION MANUAL 1 2 ZONE FIRE ALARM PANEL Display amp Controls Here 15 the fascia for the Premier Elite Operating Instructions To Reset From Fire Col Normal lm FIRE ZONES 2
2. POWER SUPPLY FLT 7 mes Premler Ek EB ER GEN FLT STOP START SILENCE RESET LED TEST F R E ALAR RO L PAN E L IES DK FAUTTONE GENERAL eS EXTERNAL SOUNDER WARNING EXTERNAL SOUNDER DISABLED ALARM SYSTE M S Display The Premier Elite has the following LED indicators LED COLOUR MEANING POWER GREEN The system has mains and or battery backup present The panel showing this LED only is the normal condition GEN FIRE RED There is an alarm on the system GEN FLT YELLOW There is a fault on the system Check specific LED for further information Note Not available on Premier Elite 1 zone SUPPLY FLT YELLOW There is a problem with either mains supply or battery backup FLT YELLOW There is a fault on one of the sounder circuits FIRE 1 RED There is a fire on zone 1 FAULT 1 YELLOW There is a fault in the wiring on zone 1 or a detector has been removed FIRE 2 RED There is a fire on zone 2 FAULT 2 YELLOW There is a fault in the wiring on zone 2 or a detector has been removed Approved Document No GLT MAN 118 PAGE 6 Issue 1 1 Author NRPJ Date 22 11 2006 0 e D z Elte INSTRUCTION MANUAL 1 2 ZONE FIRE ALARM PANEL Controls The Premier Elite has the following controls BUTTON LABEL USE 1 START STOP Used to silence the sounders in an alarm or to manually start the sounders to evacuate building 2 SILENCE F
3. apaku o Feder es 11 Specifications NEM 12 Electrical Specifications esses eene eene nnne teen 12 Enclosure 12 Rating EP 12 BOOK u sun u ase Mete av 13 MAINTENANCE WORK a Da 13 FALSE ALARMS 14 ALL OTHER EVENTS tb mn teer su ETE Ra us 15 Approved Document No GLT MAN 118 Issue 1 1 Author NRPJ Date 22 11 2006 PAGE 2 0 e D z Elte INSTRUCTION MANUAL 1 2 ZONE FIRE ALARM PANEL Introduction The Premier Elite 1 amp 2 zone panels have been designed to meet the requirement of a low cost easy to use fully functional fire alarm control panel is available as either a 1 zone panel or a 2 zone panel Each version has 2 sounder circuits and an alarm relay There is no configuration simply connect the detectors amp sounders and apply power The Premier Elite range also includes 4 6 and 8 zone panels These panels are NOT covered in this manual They have a separate manual The 4 6 amp 8 zone panels have the option to fit a hard wired repeater as well as having a fault output and a sounder delay option Approved Document No GLT MAN 118 Issue 1 1 Author NRPJ Date 22 11 2006 PAGE3 P E Elite INSTRUCTION MANUAL 1 2 ZONE FIRE ALARM PANEL Mains a
4. Including fuse Detection Zone open circuit wiring fault Detection Zone short circuit wiring fault Detection Zone detector removed Sounder circuit open circuit wiring fault Sounder circuit short circuit wiring fault The Premier Elite 2 zone panel also has a General Fault LED that will light when any fault is present Most of these faults will need to be checked by an engineer but the system can be checked for a removed detector by the responsible person All faults in the Premier Elite are NON LATCHING IE they can not be reset with the reset button They will clear automatically when the fault has been fixed Fault Finding Supply fault A power supply fault is indicative of one or more of the following faults Loss of Mains power Check that 230V AC is present at the mains terminal block Check mains fuse Check that there is 30 34V coming from the transformer secondary Check charger fuse FS1 Loss of Battery power Check that 2 X 12V batteries are fitted in series to give 24V backup Check battery fuse FS2 Check that battery connections are secure Check that the batteries are not over 5 years old Approved Document No GLT MAN 118 PAGE 9 Issue 1 1 Author NRPJ Date 22 11 2006 0 e D z Elte INSTRUCTION MANUAL 1 2 ZONE FIRE ALARM PANEL Zone Fault A Zone Fault is indicative of one or more of the following faults Open Circuit fault Check that the correct end of line
5. AULT TONE Used to silence the panel s internal buzzer in a fault or alarm condition 3 RESET Used to return the panel to its normal condition after an ALARM condition Reset will not clear faults 4 LED TEST To check that all indicator LEDs are working Use as part of the daily weekly fire alarm inspection Note that the controls can only be used after the keyswitch has been turned to the ON position Approved Document No GLT MAN 118 Issue 1 1 Author NRPJ Date 22 11 2006 PAGE 7 p z Elte INSTRUCTION MANUAL 1 2 ZONE FIRE ALARM PANEL Alarm Condition amp Resetting an alarm The Premier Elite signals an alarm by the following Turn on the General Fire LED Turn on the Zonal Fire Indicator Turn on internal buzzer Start a ny sounders connected to the panel s sounder circuits Activate the fire relay if fitted What to do in the event of a fire Follow the building evacuation procedure and check that everyone has left the building safely The building fire officer or responsible person should CAREFULLY enter the building and locate the area of the alarm from the fire alarm panel Investigate to determine the cause of the alarm Look for the detector in the zone in alarm that signalled the fire The detector that signalled an alarm will have its RED ALARM LED on If a small fire is found a suitably trained person could tackle this with a suitable fire extinguisher If a larger fir
6. Date 22 11 2006 e p Elte INSTRUCTION MANUAL 1 2 ZONE FIRE ALARM PANEL Specifications Electrical Specifications ELECTRICAL DESCRIPTION VALUE MAINS VOLTAGE 230V AC 10 50 60 Hz BATTERY VOLTAGE 24V DC 2 X 12V SLA BATTERY CHARGER SIZE 1 AMP ZONE VOLTAGE NO EOL FITTED 21V DC NOMINAL 20 22 5V SOUNDER ALARM OUTPUTS 2 x 400mA 24V DC Nominal AUXILIARY FIRE OUTPUT 1 x RELAY SELV 1A MAX NUMBER OF ZONES 1or2 MAXIMUM ZONE CAPACITY 20 DEVICES PER ZONE ZONE END OF LINE DEVICE 10 K RESISTOR SOUNDER END OF LINE DEVICE 10 K RESISTOR CHARGER VOLTAGE 27 6V DC NO BATTERY CONNECTED MAINS FAILED CURRENT BUZZER ON 48mA 1 ZONE 66mA 2 ZONE MAINS FAILED CURRENT BUZZER OFF 28mA 1 ZONE 46mA 2 ZONE Enclosure Specifications DESCRIPTION VALUE ENCLOSURE SIZE 355 x 275 x 100 mm TOP CABLE ENTRIES 12 x 19mm DIA GROMMETED ENTRIES BOTTOM CABLE ENTRIES 2 x 19mm KNOCKOUT ENTRIES REAR CABLE ENTRIES 2 SNAP OUTS 60 x 20mm Fuse Ratings FUSE NO DESCRIPTION RATING FS1 Charger Fuse 1 6A time delay 5 x 20mm glass FS2 Battery Fuse 1 6A time delay 5 x 20mm glass 53 Sounder circuit 800mA time delay 5 x 20mm glass INLET FUSE Mains Protection Fuse 2A Quick Blow HBC 5 x 20mm ceramic Approved Document No GLT MAN 118 Issue 1 1 Author NRPJ D
7. Premier Elze FIRE ALARM CONTROL PANEL Instruction Manual Oro 2 e p Elite INSTRUCTION MANUAL 1 2 ZONE FIRE ALARM PANEL INDEX INDEX S vs ce vasa E 2 Introdueti n Y 3 Mains Balffery uso 4 Connecting the mains u eroe RR PER RE nu u mashu 4 Connecting the Datteries ioo Ip tor E wu 4 Detectors amp sounders ieiee e het terrere ti e e EUER 5 Wirina 6 COLE CLONS 5 Warme the SOUDdets eit tese nie anu beris 5 Display A Controls rte eade pepe ie MERERI E Hie teas le EA e ne Re 6 Display X 6 7 Alarm Condition amp Resetting an alarm a 8 What to do in the event of a fire 8 Resetting from an alarm 8 Fault display amp fault finding 9 Fault L suspa 9 SUpPPLy 9 Zone 10 Sounder Circuit Fault oaeveleseeieasiaseiecesees 10 Battery Calculation ives sene Hate PEN 11 sample Calculati n oic e teer
8. ate 22 11 2006 PAGE 12 D s UU INSTRUCTION MANUAL 1 2 ZONE FIRE ALARM PANEL Log Book MAINTENANCE WORK DATE TIME ZONE LOCATION REASONFOR WORK WORK CARRIED OUT ADDITIONAL WORK REQUIRED SIGNED Approved Document No GLT MAN 118 Issue 1 1 Author NRPJ Date 22 11 2006 PAGE 13 p 82127 INSTRUCTION MANUAL 1 2 ZONE FIRE ALARM PANEL FALSE ALARMS DATE ZONE CAUSE IF KNOWN MAINTENANCE MAINTENANCE CATEGORY FURTHER SIGNED LOCATION OR ACTMTIES IN 5 NEEDED FINDINGS FALSE ALARM ACTION ALARMAREA YES NO REQUIRED Approved Document No GLT MAN 118 PAGE 14 Issue 1 1 Author NRPJ Date 22 11 2006 p ALL OTHER EVENTS 82127 INSTRUCTION MANUAL 1 2 ZONE FIRE ALARM PANEL DATE TIME ZONE LOCATION DETAILS OF EVENT ACTION DATE INTIALS INCLUDING CAUSE IF REQUIRED COMPLETED Approved Document No GLT MAN 118 PAGE 15 Issue 1 1 Author NRPJ Date 22 11 2006
9. e is found leave the building immediately and contact the fire brigade If no fire is found make a note of the detector that signalled fire and look for anything nearby that could be the cause of the activation eg cooking or use of a hot air gun etc Record findings in the fire alarm log book Resetting from an alarm condition After the relevant action has been taken the Premier Elite fire alarm panel can be reset by the following 1 2 3 Press Stop Start sounder button BUTTON 1 This will silence the external sounders Press Silence Fault Tone button BUTTON 2 This will silence the panel s internal buzzer Press the Reset button BUTTON 3 This will return the panel to it s normal condition If the panel goes straight back into alarm then the cause of the alarm has not been cleared This could be a detector still exposed to smoke or a call point still in the active position Press Buttons 1 amp 2 on the panel then investigate for a call point or detector that still has its RED ALARM LED on Reset the call point or clear the smoke If the problem persists contact an engineer Approved Document No GLT MAN 118 PAGE 8 Issue 1 1 Author NRPJ Date 22 11 2006 0 e D z Elte INSTRUCTION MANUAL 1 2 ZONE FIRE ALARM PANEL Fault display amp fault finding The Premier Elite 1 amp 2 zone panels monitor for the following faults Low or failed mains Including fuses Low or failed battery
10. el is working correctly Short Circuit Fault Check that the correct end of line has been fitted 10k resistor Check that ALL sounders Bells etc are POLARISED and are fitted the correct way round see diagram after list Check for shorts to the cable screen As a panel check remove cable 8 fit EOL at the panel If the fault clears the panel is working correctly SND Note If non polarised alarm devices eg some types of old mechanical bell or a relay are 10K used then a diode will End of line Resistor have to be placed in line with the device to enable fault monitoring They may also need a back EMF protection diode symptoms Chattering sounder relays that don t turn off Approved Document No GLT MAN 118 PAGE 10 Issue 1 1 Author NRPJ Date 22 11 2006 EM E p Elte INSTRUCTION MANUAL 1 2 ZONE FIRE ALARM PANEL Battery Calculation Here are the current consumption of the Premier Elite panels in various conditions Control Panel Model Mains Fail Mains Fail Mains fail buzzer sounding buzzer silenced panel in alarm Premier Elite 1 Zone 48mA 28mA 113mA Premier Elite 2 Zone 66mA 46mA 99mA Sample Calculation A Premier Elite 2 zone panel has the following items connected Zone 1 2 x MCP 4 x Optical 2 x heat detector Zone 2 1 x MCP 7 x Optical 1 x heat detector Sounder CCT 1 2 x Maxi
11. mp Battery Connecting the mains The Mains supply to the FACP is fixed wiring using Fire resisting 3 core cable Between 1 mm and 2 5mm or a suitable 3 conductor system fed from an isolating double pole switch fused spur fused at 3A IT SHOULD NOT BE CONNECTED THROUGH AN RCD This should be secure from unauthorised operation and be marked FIRE ALARM DO NOT SWITCH OFF The supply must be exclusive to the Fire Panel MAKE SURE ANY SPARE ENTRY HOLES ARE COVERED WITH THE GROMMETS PROVIDED Connecting the batteries The Premier Elite requires 2 x 12 V sealed lead acid SLA batteries The two batteries are wired in series The ve of one battery is connected to the red battery lead The of the other battery is connected to the black battery lead The ve of the first battery is connected to the of the second battery using the link wire supplied Although there are many sizes of suitable battery the sizes we usually recommend are 12V 2Ah for standard backup or 12V 7Ah for extended backup 72 hour or more and the enclosure has been designed to hold these two battery sizes A Co A Le INTERCONNECTING TOPCB ABLE BATTERY INTERCONNECTING CABLE SEALED LEAD ACID BATTERY SEALED LEAD ACID BATTERY SEALED LEAD ACID BATTERY 12V 7 Ah 12V
12. resistor 10K has been fitted Check that there are no breaks in the cable and that all screw connections are secure Check that no detectors have been removed from the circuit Check that all detectors are correctly fitted to the base As a cable check remove zone wire from panel amp measure resistance Should read 10k end of line resistance If a break is found splitting the line in half amp fitting EOL will help determine which section of cable has the fault As a panel check remove cable 8 fit EOL at the panel If the fault clears the panel is working correctly Short Circuit Fault Check that the correct end of line has been fitted 10k resistor Check that no equipment other than detectors or call points has been fitted to the zone Check for shorts to the cable screen Check that none of the heads have become damaged remove one at a time As a panel check remove cable amp fit EOL at the panel If the fault clears the panel is working correctly Sounder Circuit Fault A Sounder Fault is indicative of one or more of the following faults Sounder Open Circuit fault Check that the correct end of line resistor 10K has been fitted Check that sounder fuse FS3 is intact Check that there are no breaks in the cable and that all screw connections are secure As a panel check remove both circuits cable amp fit both EOLs at the panel If the fault clears the pan
13. tone sounder Sounder CCT 2 4 x Maxitone sounder ITEM QUIESCENT ALARM PREMIER ELITE 2 66mA 99mA MCP 40 OPTICAL 100uA 40mA HEAT 40mA MAXITONE SOUNDER 25 To calculate the required battery backup required we use the equation Battery Size Standby time in Amp Hours 1 25 x TALM x X Where Maximum time in hours required for the alarm Ve hour is most common time Total Alarm Current in amps for all alarm devices connected to the alarm circuits Standby time in hours for the system after mains failure normally 24 48 or 72 hr Quiescent current in amps of control panel in fault condition because of mains failure PLUS all detection zones PREMIER ELITE ALM 6 X MAXITONE ALARM 1 X DETECTOR ALM MCP QU 10 X OPT QU 3x HT QU 0 099 0 025 1x 0 040 3x0 10x0 0001 3x0 00005 0 099 0 15 0 04 O 0 0010 0 00015 0 29015 Amps PREMIER ELITE QU 6 X MAXITONE QU QU 11 X OPT QU 3 x HT QU 0 066 6x0 3x0 11x0 0001 3x0 00005 0 066 0 0 0 0011 0 00015 0 06725 Therefore Battery size 1 25 X 0 5 x 0 29015 24 x 0 06725 1 25 X 0 145075 1 614 1 25 x 1 759075 2 19884 Ah So 2 2 Ah batteries will be suitable for this installation Approved Document No GLT MAN 118 PAGE 11 Issue 1 1 Author NRPJ

Download Pdf Manuals

image

Related Search

Related Contents

Notice ALT2086 & 2106 (ES).qxp  FASTCOM™: ESCC-ISA HARDWARE MANUAL  USER MANUAL ULTIMA RATIO  Télécharger en pdf – 1037 Ko  SEMAINE DU 4 AU 10 SEPTEMBRE 2013  Fronius Galvo: Symbolerklärung und Standortwahl  Mio serie 200, serie 300  Notice utilisateur  GFI BackUp Network, SMA, 1-9u, 1y  • Ne posez aucun objet sur ou aproximite des couvercles de coussin  