SIGNAL ISOLATION CONVERTER

image

Contents

1. Operating location Installed at a place where no corrosive or conductive gas liquid and dust exists Ambient temperature 10 C 50 C no condensation and freeze Storage temperature 20 C 60 C Humidity 90 RH Vibration Below 5 9m sec 0 6G Altitude Below 1000m 3280ft Operating Environment III Terminal Definition Power input terminal Input voltage AC 90 260V 50 60Hz Ground terminal for equipment 12 DC 12V 20mA Max First analog input terminal Voltage input JPlshort circuit pin is moved to DC OV 10V input input impedance 20kQ Current input JP1short circuit pin is moved to DC 0 20mA input input impedance 2500 Second analog input terminal Voltage input JP2short circuit pin is moved to AI2 GD DC OV 10V input input impedance 20k Current input JP2 short circuit pin is moved to DC 0 20mA input input impedance 2500 First voltage signal output terminal VO1 GO1 Output range DC 0 10V Output current lt 5mA output load resistance needs 2kQ First current signal output terminal Output range ACE S13A is 0 20 mA ACE S13B is 4 20 mA output load resistance needs lt 5000 Second voltage signal output terminal VO2 GO2 Output range DC 0 10V Output current lt 5mA Output load resistance needs 2 2kQ Second current signal output terminal Output range ACE S13A is 0 20 mA ACE SI3B is 4 20 mA Outp
2. SIGNAL ISOLATION CONVERTER Type ACE S13A 13B nol gem cm z ACE S02 02B 02C ACE S04 06 ACE S08 09 ACE S10 ACE S12 ACE S13A 13B ACE S Series Auxiliary Controller Position Detector Proportional Differential Coupler Speed Converter Feed Back Controller Multi function Controller Signal Distributor Signal Isolation Converter The variation angle tension weight and angle bias on two axes detected by synchronization machine can be converted as DC voltage a converter can be controlled to operate at the same speed synchronous operation constant tension operation single to synchronous operation Built in tilt mechanism can slowly increase or decrease signals set by frequency to reduce the mechanical impact Can select as a proportional differential controller One proportional coupler can connect to six converters and control five proportional differential couplers Built in tilt mechanism can slowly increase or decrease signals set by frequency to reduce the mechanical impact The rotational speed of a motor can be converted as converter frequency input through electrical signal by an RPM generator or photo interception pulse generator Can be equipped with a potentiometer as constant tension for cloth line or plastics Linear and loose conversion can be used with an RPM generator as linear control or motor constant control Built in tilt mechanism can slowly increase or decrease sign
3. als set by frequency to reduce the mechanical impact Remote control Remotely control to start accelerate decelerate and stop a converter and can automatically memorize operation frequency during power failure Traverse control Used for transverse equipment so that can move left or right PLC multi step control Execute procedure control according to the setting phase and recycle it Input current can be simultaneously delivered to five sets of output after converted Current or voltage output can be switched For the applications of multiple conversion system pressure signals can be simultaneously delivered to multiple converters so that achieve constant pressure Used at a place for output and input conversion I I I V V V and V I or isolation ACE S13A The range of current output is DC 0 20mA ACE S13B The range of current output is DC 4 20mA Introduction Thank you for purchasing ACE S13 controller Please carefully read this user manual before the installation In order to correctly operate and use please attach this user manual on that machine so that can provide the reference of maintenance and service or troubleshooting in the future Safety Notices Please carefully read this user manual and pay attention to safety notices symbols or text specified in DANGER and NOTE prior to performing the installation wiring operation maintenance or troubleshooting DANGER Indicates the op
4. ems should be performed N Signal lines should be kept away from high voltage or power lines Don t bundle with high power lines A Don t connect control loop terminals during the power delivery to avoid damage caused by the surge impact A Please confirm power indicators on a panel turn off to perform the removal after the power is disconnected A Please connect according to terminal symbol when wiring and lock screws to avoid trip A Please recover the upper cover to avoid electric shock after wiring is completed A The wiring operations must be performed by the qualified staff Don t install at a place where to have high temperature humidity oil lint iron Ambient powder copper powder dust and corrosion Environment Heat dissipation should be considered when installing in a control panel The ambient temperature should not be greater than 50 C Contents Features SS a Se Se eee a ee ec Leu Se eu II Specifications HI Terminal Definition IV Terminal Position and Dimension Diagrams zi T IP I Features Two sets of signal isolation conversion circuit output and input isolation can invert V V I V and I I respectively II Specifications 90 260V 50 60Hz About 5 Voltage input 10V Voltage output 0 10V Output Signal Current output ACE S13A is 0 20 mA ACE S13B is 4 20 mA
5. eration could cause severe injury or death if it doesn t execute according to instruction on the user manual A NOTE Indicates the operation could minor injury or product damage if it doesn t execute according to instruction on the user manual X Even though indicates the level of light damage it could cause severe injury Only qualified staff can carry out the installation wiring trial run or troubleshooting z Qualified staff Those who get familiar with the principle structure characteristic operation procedure and installation of ACE controller to take safety measures and avoid danger as well as carefully read the user manual Selected power voltage must have the specifications identical to controller input voltage If wrong voltage 15 connected internal control circuit will be burned out Please pay special attention to that A Wiring between ACE controller and converter should be as short as possible A The length of output terminal VO IO and and converter frequency terminal Vin and Gnd should be within 3m A Please select appropriate line diameter when wiring main loop power A Ground lines should conform to the third type ground resistance below 1000 N Main loop power and control loop lines should be connected to ground point GRD Wiring and Signal lines should adopt twisted pair or isolated lines to avoid noise interference Installation and the ground it
6. ut load resistance needs lt 5000 Note 1 Two defaults and AI2 are set as voltage input 1 IV Terminal Position and Dimension Diagrams Terminals at lower layer Terminals at upper layer Screw 4 2 Unit mm Fig 1