Home

Data Sheet - AceCom Networks Pte Ltd.

image

Contents

1. Power supply Power supply 48VDC 40VDC to 60VDC Power supply Redundant 1 1 Protected Power consumption 21 watts maximum Chassis 6U High 19 inch rack mounting shelf Time slot selection Any to any through an internal best byte non blocking TSI switch AceCom Networks Clock Optica Clock Internal AT amp T TR62411 Telcordia GR 1244 CORE Stratum 3 Stratum 4 Enhanced and Stratum 4 ETSI ETS 300 011 ITU T G 813 Option 1 Loop timed External 75 Ohms 2 048 MHz 1 544 MHz Management and Control Serial Management Port RS232 COM Port 10 100 BaseT for remote management over a LAN 10 100 BaseT Telnet over a TCP IP network Command Language Command Line Interface English text commands Windows based GUI optional Core System All items of the Core System must be ordered The Core System consists of a 19 inch chassis b Control card and TSI with serial and LAN management ports c 2 x 48VDC input power supply card s for Redundant operation d AC to 48VDC DC converter for universal AC mains input if required to connect the equipment on AC mains e GUI configuration software f User manual Interface cards g 8 Port E1 Ports Interface card 120 ohms balanced RJ 45 1282 E1 h 8 Port T1 Ports Inter
2. AceCom Networks MegaConnect 64 Port E1 T1 10 BaseT Ethernet Digital Access Cross Connect Product Brochure amp Data Sheet AceCom Networks Pte Ltd 200 Jalan Sultan 02 13 Textile Centre Singapore 199018 Phone 65 6295 3233 Fax 65 6295 3133 E mail sales acecomnet com Web Site http www acecomnet com AceGom Networks multiplexers CIII Optical Lei a Ili SS 64 Port E1 T1 POPE EEF I 10 BaseT Ethernet Digital Access Cross Connect Description The MegaConnect 64 Port E1 T1 10 BaseT Ethernet Digital Cross Connect Switch isa E1 T1 10 BaseT Ethernet digital cross connect switch which presents its user an easy to use yet a sophisticated platform to cross connect up to 64 E1 T1 10 BaseT Ethernet ports The MegaConnect 64 Port E1 T1 10 BaseT Ethernet Digital Cross Connect Switch offers full cross connect functionality to cross connect and or aggregate DS Os n x64Kbps consecutive data channels and fractional E1 T1 channels to full E1 T1 channels or between the 64 E1 T1 10 BaseT Ethernet ports Tag Ana S ag The MegaConnect 64 Port E1 T1 10 BaseT Ethernet Digital Cross Connect Switch occupies only a 6U high rack space and is a complete 19 inch stand alone unit that provides connectivity for up to 64 Port E1 T1 ports The unit operates on a 48VDC input power supply AC input adapteris optionalfor AC mains operation The system is supplied with an easy to use Windows 95 98 Me XP Graphical User In
3. 1s T1s and Ethernet links over a DS3 T3 channel Note This does not however substitute Firewall protection which must be installed separately AceCom Networks multipli Crt TTI OPtical Front view CLK CLOCK INT INTERNAL POAT PE i EXT EXTERNAL SW SWITCH ERR ERROR 8 IF Cars _ gt Redundant Power Supply Card Rear view EXTE1 T1 CLK i 48 VDC INPUT i Ea i EARTH i OO nI RS 232 i vla alh ah aih i vlka lh dh ah i vla alh ah aih i vla alh ah aih i vlka alh ah aih mi as vla alh dh aih DOI i aih E3 DS3 STM 1 PORT Lt RX il ols ulh is ls ulh ils ols ulh ils oils ulh 00 Applications e E1Cross Connect e 11Cross Connect e E1toT1 Cross Connect E1 lt gt T1 Converter for data applications e E3 toE1 T1 10 100 BaseT Ethernet Cross Connect e DS3toE1 T1 10 100 BaseT Ethernet Cross Connect Indications and Alarm Monitoring e E3 Loss of signal e DS3 Loss of signal e
4. Loss of incoming signal at any E1 T1 Port e Configuration error alarm e Clock status e 1to8channel LED indicators to indicate the status of each E1 T1 channel e 3 Volts power supply e 48VDC present e Configuration error Programmable Features e Specifying the priority sequence for clock selection e Enabling or disabling E1 T1 channels masking of the E1 T1 channels that are not is use e Creating a cross connect between E1s at DS O level single time slot level using the Windows based easy to use GUI e Telnet interface for remote programming by using text commands Status Monitoring e Clock selection e Status of alarms e Enabled Disabled status of E1 T1 channels e Monitoring of the MegaConnect status and configuration AceGom Networks Technical Specifications E1 Interface Line rate E1 2 048 Mbps 50 bps Available Time Slots 1 31 Framing G 704 Electrical G 703 Jitter G 823 Impedance 120 Ohms Connector RJ 45 F Clock Internal Stratum3 level Loop timed External 75 Ohms 2 048 MHz 1 544 MHz T1 Interface Line rate T1 1 544 Mbps 50 bps Available Time Slots 1 24 Framing structure as per ITU CCITT G 704 Framing options D4 ESF Selectable Line coding AMI B8ZS Selectable Electrical ITU T G 703 7 Jitter ITU T G 823 ITU T 1 431 Impedance 100 Ohms 7 i Connector RJ 45 F Clock Internal Stratum3
5. face card 100 ohms balanced RJ 45 1282 T1 i 8 X 10 100 BaseT Ethernet Interface cards 1412 1413 BaseT ii i AceGom Networks m System Management e Windows 95 Windows 98 Windows ME and Windows XP based GUI e CLI Command Line Interface Technical specifications are subject to changes without notice Revision 06 June 15 2011 AceCom Networks Pte Ltd 200 Jalan Sultan 02 13 Textile Centre Singapore 199018 Phone 65 6295 3233 Fax 65 6295 3133 E mail sales acecomnet com Web Site http www acecomnet com
6. level Loop timed External 75 Ohms 2 048 MHz 1 544 MHz AceGom Netw 10 100BaseT Interface orks Number of interfaces 8 per interface card Interface types 10BaseT Standards compliance IEEE 802 3 2002 RFC1662 RFC2615 X 86 RMII Interface rate Programmable in steps of 512 Kbps upto 1920 Kbps per 10 100BaseT Interface 512 1024 1536 1920 Kbps Protocol User Programmable HDLC and LAPS mapping Connectors RJ 45 10 100 BaseT Electrical E3 Interface Number of E3 interfaces 1 Bit rate 34 368 Mbps Bit rate tolerance 20ppm Line Code HDB3 Frame structure As per G 751 Interfaces As per G 703 Connectors BNC Co axial Un balanced Impedance 75 Ohms Permissible Attenuation 12dB 17184 KHz Signal level to declare loss of signal condition 35dB maximum Signal level to clear loss of signal condition 15dB minimum AceGom Networks DS3 T3 Interface Number of DS3 interfaces 1 Bit rate 44 736 Mbps Bit rate tolerance 20ppm Line code _B3ZS Framing Meets ANSI T1 404 M13 or C bit parity Pulse shape Meets ANSI T1 102 1993 and Bellcore GR 499 CORE Connectors BNC Co axial Un balanced Impedance 75 Ohms Signal level to declare loss of signal condition lt 20mV Signal level to clear loss of signal condition gt 90mV
7. terface that provides the user a complete control to prepare multiple configuration maps and store them as data files It may be accessed using CLI Command Line Interface through a Serial COM Port of a PC using HyperTerminal text commands It may be also accessed remotely over a 10BaseT interface by assigning a unique IP Address to the DACS Password protection to prevent un authorised access is also available please see Note Dry contact relay alarms are also available atrear ofthe system to connectthe system toan external alarm output The MegaConnect 64 Port E1 T1 10 BaseT Ethernet Digital Cross Connect Switch also allows remote access for configuration and monitoring using Telnet Optional System Configurations a DS 0 Cross Connect 64 Port E1 T1 10 BaseT Ethernet Cross Connect provides a full non blocking cross connect capability at DS 0 64Kbps time slot level between all E1s T1s and 10 100 BaseT Ethernet ports b DS 0 Cross Connect 48 Port E1 T1 10 BaseT Ethernet Cross Connect with and E3 Interface provides the capability to convert cross connect upto 48 E1s T1s and 10 100 BaseT Ethernet ports to an E3 interface Useful for transporting E1s T1s and Ethernet links over an E3 channel c DS 0 Cross Connect 32 Port E1 T1 10 BaseT Ethernet Cross Connect with a DS3 T3 Interface provides the capability to convert cross connect upto 32 E1s T1s and 10 100 BaseT Ethernet Ports to a DS3 interface Useful for transporting E