Contents
1. Library Name__ Cylindrical Li ion Rechargeable Batteries Date 2010 11 13 Cylindrical Li ion Batteries Specification Batteries Type LIC14500 Prepared Date Checked Date Approved Date 13 11 2010 13 11 2010 13 11 2010 Library Name__ Cylindrical Li ion Rechargeable Batteries Date 2010 11 13 1 Primary technical Parameters Type Rechargeable Lithium ion Cylindrical Cell Dimension D 14 140 2mm 14 1 H 48 5 0 5mm CsmAh 700 CsmA 700 d Nominal Voltage 3 7V Nominal 700 mAh Capacity Minimum 650 mAh when discharged at 0 2CsmA to 2 75V Recommended Charging 140mA 700mA charge termination control Conditions parameters taper current 7 mA at 4 2V a Max continuous 1400 mA discharge current Service Life 300 cycles 280 CsmAh Weight Approx 20g Internal 80mQ max at 1000Hz Resistance unit mm Charging Voltage 4 200 0 05V Ambient Charging 0 45 C Temperatire Discharging 20 60 C Range Storage lt b t36C Note 1 Cs the rated capacity unit Ah or mAh 2 Lithium content less than 20g Subject to change without prior notice 2 Performance Test item Test conditions Requirements 1 Outside Visual check No abnormal stain Appearance Deformation nor damage 2 Standard test Measurements are carried out at 20 5 Cand relative conditions humi
2. not pierce battery with a sharp object such as a needle Do not hit with a hammer step on or throw or drop to cause strong shock Donot disassemble or modify the battery Donot solder a battery directly Do not use a battery with serious scar or deformation Warning Do not put battery into a microware oven dryer or high pressure container Do not use battery with dry cells and other primary batteries or batteries of a different package type or brand Stop charging the battery if charging is not completed within the specified time Stop using the battery if abnormal heat odor discoloration deformation or abnormal condition is detected During use charge or storage Keep away from fire immediately when leakage or foul odor is detected If liquid leaks onto your skin or clothes wash well with fresh water immediately If liquid leaking from the battery gets into your eyes do not rub your eyes Wash them well with clean water and go to see a doctor immediately Caution Store batteries out of reach of children so that they are not accidentally swallowed lf younger children use the battery their guardians should explain the proper handling Before using the battery be sure to read the user s manual and cautions on handling thoroughly Thoroughly read the user s manual for the charger before charging the battery For information on installing and removing from equipment thoroughly read the user s manual fo
3. d capacity No rupture fire smoke Nor critical damage 290 CsmAh Library Name__ Cylindrical Li ion Rechargeable Batteries Date 2010 11 13 4 Safety Evaluation Test Item Test Conditions Requirements 1 Hot Oven Test The charged batteries are to be heated in a gravity No fire Nor explosion convection or circulating air oven The temperature of the oven is to be raised at a rate of 542 C per minute The oven is to remain for 30 minutes at 130 2 C before the test is discontinued 2 Short Circuit Test After fast charge at 20 2 C Connect battery No fire Nor explosion terminals with electric wire electric resistance 50mQ or less And stop the test when the temperature of battery is 10 C lower than peak temperature 3 Overcharge After discharged at 1 CsmA and to 2 75V the No fire Nor explosion batteries shall be charged at 3 CsmA current with a voltage limit of 4 6V chargeing is continued for 8 hours 4 Dip test The charged battery shall be dipped in water for 24h No fire Nor explosion in an ambient temperature of 20 C 5 C 5 Charge State of Battery before shipment To be determined Recommendation Approx 3 75 3 85V 30 charge 6 Duration of guarantee the product We can keep on the quality in six month 7 Protection When Li ion rechargeable battery is used over the permitted voltage or current electrolyte ma
4. dity of 65 20 without other specified condition Accuracy of voltmeters and ammeters used in test is equal to or better than the grade 0 5 3 Standard Cells shall be charged continuously at the constant charge current of 0 5 CsmA to 4 2V then charge at the constant voltage of 4 2V until the end current of mA 4 Standard Cells shall be discharged continuously at the constant discharge current of 0 2 CsmA to 2 75V 5 Fast charge Cells shall be charged continuously at the constant Library Name Cylindrical Li ion Rechargeable Batteries Date 2010 11 13 current of 1500mA to 4 2V then charge at the constant voltage of 4 2V until the end current of 7mA 6 Open circuit 23 700 voltage OCV 7 Rated Cells shall be charged in Item 3 and discharged in Item Rated capacity 4 within 30minutes after full charged If the discharge o Capacity duration does not reach the specified value the test 27 00 CsmAh may be repeated up to three times in total 8 high rate Cells shall be charged in Item 3 and discharged Discharge capacity discharged continuously at the constant current of 1 CsmA to 2 75V 295 CsmAh Capacity within 30 minutes after full charged If the discharge duration does not reach the specified value the test may be repeated up to three times in total 9 Cycle Life Cells shall be charged continuously at the constant 2300 cycles current of 1C5mA t
5. o 4 2V and discharged continuously oo at the constant current of 1C5mA to 2 75V A cycles defined as one charge and discharge Carry out cycles until discharge capacity lt 80 CsmAh 10 Low Cells shall be stored under 20 C 2 C for 16h 24h after Discharge capacity Temperature charged in Item 3 then discharged at constant current 260 CsmAh discharge of 0 2 CsmA to 2 75V 11 Storage Cell shall be charged in Item 3 and stored in a Remaining capacity characteristics temperature controlled environment at 20 5 C for 28 290 CsmAh days After storage cell shall be discharged in Item 4 to obtain the remaining capacity 3 Mechanical test Test Item Test Conditions Requirements 1 Vibration Test Vibrate test sample for 90 minutes per each of the three mutually perpendicular axis x y z after rated charge Amplitude 0 38mm 10 30Hz 0 19mm 30 55Hz Frequency 10 55Hz 1oct min Direction X Y After test cells are discharge at constant current of 0 2IhmA and cycles per 1 3 and 1 4 for 3 cycles to obtain recovered capacity No rupture fire smoke Nor critical damage 90 CsmAh 2 Drop Test Drop 100 charged test sample from 1 meter above onto concrete board with more than 5cm thickness two times each for every direction after rated charge After test cells are discharge at constant current of 0 2C5mA and cycles per 1 3 and 1 4 for 3 cycles to obtain recovere
6. r the specific equipment Batteries have life cycles If the time that the battery powers equipment becomes much shorter than usual the battery life is at an end Replace the battery with a new same one Remove a battery whose life cycle has expired from equipment immediately When the battery is thrown away be sure it is non conducting by applying vinyl tape to the and terminals When not using battery for an extended period remove it from the equipment and store in a place with low humidity and low temperature While the battery pack is charged used and stored keep it away from objects or materials with Library Name__ Cylindrical Li ion Rechargeable Batteries Date 2010 11 13 static electric charges Ifthe terminals of the battery become dirty wipe with a dry clothe before using the battery The battery can be used within the following temperature ranges Do not exceed these ranges Charge temperature range 0 C to 45 C Discharge temperature range 20 C to 60 C When using equipment
7. y disassemble and this case will affect safety performance of Li ion rechargeable battery So PTC heat fuse and protection circuit module were used in order to prevent overcharge overdischarge and overcurrent The parameters of protection circuit module as follows overcharge protection voltage 4 250 0 025V overdischarge protection voltage 2 30 0 08V overcurrent protection 3 0A 8 Handling precautions on Lithium lon Rechargeable Battery To assure product safety describe the following precautions in the instruction manual of the equipment Danger When charging the battery use dedicated chargers and follow the specified conditions Library Name__ Cylindrical Li ion Rechargeable Batteries Date 2010 11 13 Use the battery only in the specified equipment Donot connect battery directly to an electric outlet or cigarette lighter charger Do not heat or throw battery into a fire Do not use leave battery close to fire or inside of a car where temperature may be above 60 C Also do not charge discharge in such conditions Donotimmerse throw and wet battery in water seawater Do not put batteries in your pockets or a bag together with metal objects such as necklaces Hairpins coins or screws Do not store batteries with such objects Donot short circuit the and terminals with other metals Donot place battery in a device with the and in the wrong way around Do
Download Pdf Manuals
Related Search
Related Contents
system operations and programming guide Fronius IG OPERATOR`S MANUAL - Agilent Technologies Troubleshooting Guide Kerbl 84472 Amethyst User's Manual DeLOCK RS-232, 1m MPS-200 e-drum-modul bedienungsanleitung OPTICAL MEASURING INSTRUMENTS ML9001A ADTRAN T1 User's Manual Copyright © All rights reserved.