1. Do not spray the cleaning solution directly on the handpiece 2 Wipe debris off the end of the optic fibers at the handpiece with an alcohol soaked cotton swab 3 Place the handpiece in a cassette or sterilization pouch and seal 4 Autoclave the handpiece for 20 min at 250 F 121 C or 15 min at 273 F 134 C Detailed care and maintenance instructions are available upon request or go to www hu friedy com CAUTION Do not place the handpiece on the bottom shelf of the sterilizer To prevent exposure to excess heat place handpiece and tips on the middle and top shelves of the sterilizer MAINTENANCE CLEANING FIBER OPTIC LIGHT Wipe debris off the end of the optic fibers at the handpiece with an alcohol soaked cotton swab Fig 5 CAUTION Do not use any sharp pointed tools to clean the optic fiber end face In case the light becomes dim contact your dealer CHANGING FIBER OPTIC LIGHT Disassemble the handpiece from the handpiece cord See Installation amp Assembly Remove the handpiece sleeve Use a small screw driver to push the lamp out Fig 6 Align the lamp pins of the new lamp with the holes and push the lamp into place Align the mark on the handpiece sleeve with the same mark on the handpiece cord Push the sleeve to the cord until it clicks Fig 7 CAUTION Do not touch glass part of new lamp and exercise care when mounting a new lamp to avoid dislodging the o ring from the gro
2. Symmetry HANDPIECE User Manual Benutzerhandbuch Manuel de l utilisateur Manuale per l utente Manual del Usuario Manual do Usu rio 21 27 a F V Symmetry Q Thank you for purchasing the Hu Friedy Symmetry IQ handpiece This product is intended to be operated by dental professionals only The Symmetry IQ handpiece must be used with a Hu Friedy Symmetry IQ control unit This device generates ultrasonic vibrations intended for use in dental applications such as scaling periodontal therapy root canal treatment and cavity preparation Read this operation manual carefully before use and retain for reference SYMBOLS AND GENERAL SAFETY 135 d e C CE marking Refers to directive 93 42 EEC SE EE 0120 including EN 60601 1 and EN 60601 1 2 Dispose of this device and its accessories via Authorized Ger th methods approved for electronic devices and EC REP E ele G lle mmm in compliance with the Directive 2002 96 CE urapean community CAUTIONS FOR HANDLING AND OPERATION Read these instructions carefully and use only as intended or instructed Safety instructions are intended to avoid potential hazards that could result in personal injury or damage to the device Refer to the user manual for your Symmetry IQ control unit or go to www hu friedy com for additional information INSTALLATION AND ASSEMBLY HANDPIECE CORD CONNECTION Align the marks on the control unit and the handpiece cord plug Gently
3. ntee neither extend the guarantee period nor begin new guarantee period Damages from breach of the guarantee described herein are limited to the cost of repair or replacement of the Unit at Hu Friedy s sole option Consequential or incidental damages resulting from breach of the guarantee described herein are hereby excluded Any statutory warranty rights shall remain unaffected by the guarantee provided herein Please contact Hu Friedy for instructions on obtaining warranty service 2007 Hu Friedy Mfg Co Inc Hu Friedy and First Because We Last are trademarks of Hu Friedy Mfg Co Inc registered in the USPat amp TMOff U S Patent No 7 159 494 Hu Friedy www hu friedy com Hu Friedy Mfg Co Inc 3232 North Rockwell Street Chicago Il 60618 USA ec ml Hu Friedy Mfg Co Inc Zweigniederlassung Deutschland Rudolf Diesel Str 8 D 69181 Leimen UPMANUALHP Q7
4. of wear CHECKING SYMMETRY TIPS FOR WEAR Locate the diagram of the tip to be measured on the Symmetry Wear Guide HF 469 2 Rotate the tip until it is flat against the card 3 Evaluate tip condition comparing length to red blue lines 1mm loss can result in 25 efficiency loss 2mm loss can result in 50 efflciency loss 12 GUARANTEE Hu Friedy at its sole option will repair or replace for a period of one year following the date of the first purchase as new item any Symmetry IQ piezo generator unit Unit that fails as a result of a defect in materials or workmanship Purchaser must return the defective Unit postage prepaid and must provide Hu Friedy with the guarantee registration card Excluded from this guarantee are damages in cases of e the Unit having been used outside of normal operating conditions e the Unit being damaged in transit e Non compliance with the manufacturer s installation instructions water pressure mains voltage e use with an electrical system that does not comply with regulations in force uses other than those specified in this manual non compliance with instructions contained in this manual service to the Unit being provided by non authorized persons 13 components exhibiting normal wear from usage e damages defects being caused by force majeure or any other condition that is beyond the control of Hu Friedy Repair service or replacement provided under the guara
5. ove WARNING Do not use the device if it appears to be defective NOTE If a failure occurs contact the supplier of your Symmetry IQ product Repair by unauthorized person may void warranty 10 SERVICE Please send your Symmetry IQ handpiece to your dealer or an authorized Hu Friedy repair center Shipping your product in its original packaging will offer the best protection against damage during shipping If sending directly to an authorized Hu Friedy repair center please include the name and address of your dealer All items must be cleaned disinfected and sterilized as described in the operating instructions before shipment TROUBLESHOOTING See User Manual of your Symmetry IQ Control Unit for details or go to www hu friedy com DISPOSAL AND RECYCLING Dispose of this device and its accessories via methods approved for electronic devices and in compliance with the Directive 2002 96 CE At the end of their life tips should be discarded in safety containers designed for this purpose HELPFUL INFORMATION The use of higher than recommended power setting may cause excessive wear or tip breakage Always remember to properly tighten the tip to handpiece using the Guardian wrench Scaling efficiency can diminish significantly with worn tips Inferior performance and poor water delivery can result from worn damaged bent or altered tips For optimal scaling efficiency we recommend checking tips regularly for signs
6. push the plug into the connector at the front of the control unit Fig 1 HANDPIECE CONNECTION Confirm there is no moisture in the handpiece connector If moisture is present dry it with cloth or air syringe Align the marks on the handpiece with the marks on the handpiece hose to properly align the electrical contacts Fig 2 Gently push straight to connect Do not twist handpiece connector to connect Place the handpiece in the handpiece cradle on the control unit To remove handpiece from the handpiece cord first remove tip then firmly grip the front section of the handpiece in one hand and the rear section of the handpiece cord plug with the other hand and pull to separate Do not twist to separate WARNING Do not touch the back end of the handpiece where electrical connections are made to the cord It may result in electric shock CAUTION Do not disconnect the cord handpiece when power to the device is switched on and the footswitch is depressed 2 Detach tip before removing handpiece 3 Push handpiece against handpiece cord plug to connect 4 Grip the plug of the handpiece cord when removing handpiece OPERATING PROCEDURES TIP CONNECTION Your Hu Friedy Symmetry piezo tip comes with its own tip carrier torque limiting wrench the Guardian Fig 3 Attach tip to handpiece using the Guardian wrench by aligning the threaded end of the tip to the handpiece Fig 4 Rotate the Guardian wrench clock
7. wise Complete installation of the tip by rotating the Guardian until you hear clicking The Guardian must be used to completely tighten the tip during installation Incomplete tightening may cause the tip to become loose or lack vibration When using the Guardian without a tip previously inserted into the tip carrier take the following step place the Guardian over the tip by slipping tip through the small hole in the bottom closed end of the tool This will position the tip within the Guardian wrench for safety and convenience o TIP REMOVAL Hold the handpiece vertically Insert the tip through the hole in the bottom of the Guardian wrench Depress wrench slightly while rotating to fully secure tip to wrench Turn the Guardian counter clockwise to loosen and remove tip from handpiece Once removed from handpiece do not remove the tip from the Guardian carrier CAUTION Proper vibration of a tip depends on correct attachment to the handpiece Always use the torque limiting Guardian wrench to ensure proper tip attachment and to eliminate over tightening or inadequate attachment of the tip Over tightening of the tip may result in damage to the handpiece or tip CLEANING AND STERILIZATION Clean and sterilize prior to first use and after each patient as noted below I Clean the outer surface of the handpiece by wiping with a soft cloth dampened with pH neutral surface disinfection solution not containing phenols
Download Pdf Manuals
Related Search
Related Contents
DOLPHIN User Manual - BenchMark Wireline washing machines installation use and maintenance =ー` TaKaSHD Samsung Ativ Tab 3 User Manual (Windows 8) Fujitsu MAG3091FC User's Manual Initimidator Spot 100 IRC User Manual Rev. 2 SPEEDWAY 9410 Use and Care Manual Philips Food processor HR7628/00 Cougar A300 power supply unit Copyright © All rights reserved.