KB2000 Serial-Internet Conversor User Manual

image

Contents

1. and set its IP unique must not conflict with other PC or device Note KingBird ge Shenzhen Kingbird network technology CO LTD KB2000 Data Converter for Internet 1 You d better set get IP from By manually for your LAN may have no DHCP server 2 Generically KB2000 A and KB2000 B are not in one LAN so you must set different network parameters depend on the LAN which be connected 2 Set other parameters KB2000 s other parameters as baud rate data format and so on You can set them depend on your device Other parameters as ID Target ID heard beat No need to reset 3 Connect with KB2000 KB2000 A connect with PC Connect its RJ45 interface with the switch or Router of the LAN by network cable then connect the RS232 interface with the COM of PC by RS232 cable KB2000 B connect with the device Connect its RJ45 interface with the switch or Router of the LAN by network cable then connect its COM port with RS232 or RS485 of the device 4 Run SCADA software to read control After set the KB2000 A and KB2000 B and connect with network you can run SCADA software to read or control or AMR Note The communication way of SCADA software must base on COM RS232 RS485 In the SCADA software please open the COM port that be connected with KB2000 A its baud rate and data format must be same with KB2000 A 6 plug and play Solution 6 1 KB2000 A Work with KB2000 B KB2000 is used as Client side it is applied to sin
2. the interface as follow IE fia2 168 1 9 MAC o0 0B 3C 01 08 E4 PYD Peck com Set Read IP 192 168 1 9 u Gateway 192 168 1 1 00 Cancel Mask 255 255 255 0 Get IP from fautomatic x Protocol TCP Target IP Pedecaecmedee Target TCP por tree Target UDP porte Shenzhen Kingbird network technology CO LTD KB2000 Data Converter for Internet x ily fiz 168 1 9 MAC 00 08 3C 01 0E E4 PYD ik General Net Set Read Baud rate 38400 Cancel Data bits E x Verify Hone x Stop bits ft x Max Mem time so WS Max Mem bytes 900 Bytes If you need to amend some parameters Please click Set button after amendment then the parameters will be set Note 1 When you set KB2000 you must input password the default password is 000000 2 If you forget your password please connect the PE pin to the GND pin when you set parameters thus the password can not be required 3 Some parameters must not be changed the software have forbid them 4 If you want to use IO function please ask for IO control protocol from our company 5 Setup Network and Application 5 1 KB2000 Application Step 1 Set KB2000 Network Parameters Generically KB2000 is connected with internet through LAN First net parameters need to be set according to the situation of LAN Please connect KB2000 with LAN then run KB2000 manage software set the parameters of Gateway and subnet Mask same as LAN
3. the program NetConvertor exe NetConvertor can manage all KB2000 in current subnet It can search KB2000 view KB2000 parameters set KB2000 and so on The interface of the program as follow KingBird or Shenzhen Kingbird network technology CO LTD KB2000 Data Converter for Internet KB2000 Data Convertor 1 13 xj File View Option Help P Bh Search Parameters Password Type setting Restore Exit H 192 168 1 9 00 0B 3C 01 0E E4 13610000001 Shenzhen KingBird Network Technology CO LTD 4 1 Search KB2000 User can find all KB2000 through Search in the subnet Please chose File menu then Search Or you can click Search button on the toolbar 4 2 View parameters Please double click the icon of KB2000 that searched or after you searched KB2000 you can click Parameters button on the toolbar Just as below picture Shenzhen Kingbird network technology CO LTD KB2000 Data Converter for Internet Parameters setting ne ily fia2 168 1 9 MAC o0 0B 3C 01 08 E4 PYD iek iNet com Set Read Name Cancel Type ID Target ID Zone valid fon Zone HO for t t s Heartbeat 5 39 Click Read button in this dialog read the parameters again 4 3 Set KB2000 If you want to amend parameters of KB2000 you can set them in the parameters setting dialog Chose a KB2000 in the list then click parameters button in the toolbar you will go to the parameters setting dialog
4. 000 can apply to all kinds of network environment network parameter and COM parameter KB2000 can be set by configuration software or by User s programming Two types of KB2000 Type A KB2000 A this type mainly for Main station Master station as control center it commonly connect with PC Type B KB2000 B this type mainly for slave station as remote terminal it commonly connect with user s devices instruments meters and so on Mainly Application based on Internet Remote AMR system LED Display information issue system water conservancy atmosphere monitoring POS network Power automatically transformer monitoring system Industry instruments and meters automation engineering Linkage or multinational group device monitoring network 2 Interface and appearance 2 1 Indicator light LED1 Above LED Double color Network cable connected it show green No connected No light if O data send and receive from Serial port It will be red LED2 Below LED Double Color when power supply connected It will show red when KB2000 connected with server it will change to green 2 2 Network interface RJ45 connect with TCP IP network Shenzhen Kingbird network technology CO LTD 2 3 COM interface RS232 or RS485 KB2000 Data Converter for Internet KB2000 have 10 pins from left to right PIN1 PIN10 they are defined as follow VCC GND UTXD1 A U
5. KB2000 when it join into one subnet its IP must be distributed depend on the network section Gateway The gateway of subnet which KB2000 accessed Subnet Mask It depends on the subnet Get IP from The type of getting IP include Manually and Automatic In Manually IP address can be set KB2000 will use the IP address which user set If in Automatic KB2000 can get the IP address by DHCP protocol DHCP server must be in the subnet if you can not get IP through automatic please use manually Protocol Network protocol support UDP and TCP Target IP KB2000 is client side working way it must have server IP The default value is Kingbird s if user don t have server can use Kingbird s server for free if quantity is less or hire Kingbird s server if quantity is more then this value no need to reset Target TCP port The TCP port for specified KB2000 communicate with Target Main machine The default value is the TCP port of Kingbird s if user don t have server can use Kingbird s server for free if quantity is less or hire Kingbird s server if quantity is more then this value no need to reset Target UDP port The UDP port for specified KB2000 communicate with Target Main machine The default value is the TCP port of Kingbird s if user don t have server can use Kingbird s server for free if quantity is less or hire Kingbird s server if quantity is more then this value no need to reset KingBird She
6. KingBir a Shenzhen Kingbird network technology CO LTD KB2000 Data Converter for Internet Ei KB2000 Data Converter User s Manual Shenzhen Kingbird Network Technology CO LTD Add 12C 12D Tower B Haiwang Building NanHai Road Nanshan District Shenzhen Guangdong China TEL 86 755 82556825 83239613 Fax 86 755 83239613 EXT 8012 Web http www kingbirdnet com EMAIL sales kingbirdnet com MSN kingbird_sales1 hotmail com SKYPE kingbird_sales1 KingBird Shenzhen Kingbird network technology CO LTD KB2000 Data Converter for Internet 1 Overview KB2000 is data protocol converter which transmits the data between RS232 RS485 and TCP IP network It is special used for Internet network data transmission also can be used in Local network KB2000 will receive the data from converter s RS232 RS485 COM Port and transmit the data to Network Data Server of TCP IP network transparently the Network Data Server will transmit data to the KB2000 s RS232 RS485 COM port In other words so long as connect two KB2000 s COM port with different PC or device their Network Port be connected with internet the different PC or device can communicate through internet KB2000 supply 10M 100M Ethernet interface upwards and supply one standard RS232 or RS485 COM port It have 16K buffer its parameters can be set by software the baud rate support from 300bps to 115200bps KB2000 can suit for all kinds of network environment KB2
7. RXD1 B Outputl Inputl GND Output2 status Input2 Pin No Definition Description For User 1 VCC Power DC6 24V 2 GND Ground 3 UTXD TXD DTU COM RS485 A RS232 TTL RXD RS485 A 4 URXD RXD DTU COM RS485 B RS232 TTL TXD RS485 B 5 Output1 Output NO 1 of IO 6 Input1 Input No 1 of IO 7 UGND Ground COM RS232 TTL RS485 Data groud 8 Output2 Output No 1 of IO 9 Status Online is high offline is low 10 Input2 Input No 2 of IO KingBird Shenzhen Kingbird network technology CO LTD KB2000 Data Converter for Internet 3 The parameters of KB2000 3 1 General parameters Name Named current KB2000 the Max length is 16bytes ASCII code Password When you set the parameters of KB2000 you must input password password is 6bytes ASCII code Type Include A and B two types Type A is mainly used in Main station Type B is mainly used in slave station ID Current KB2000 s ID Target ID If the type of KB2000 is type A this item just is used When type A wants to communicate with type B this item value is set to the ID of type B Zone valid If you want to use Zone you must set it to ON Zone The current KB2000 s Zone number of the Network if type A wants to communicate with a quantity of type B you must set type A and type B the same Zone number and the Zone valid all be set ON Heart beat The interval of KB2000 connection or communicate with remote server 3 2 Network parameters IP IP address of
8. gle PC or multi PC system The single PC or multi PC can communicate with remote equipments or devices In this way KB2000 A is used as Client side When the host machine needs to communicate with remote equipments or devices KB2000 A will send TCP connection request to specified server and communicate after power on At the same time KB2000 B which connect with equipments or devices send TCP connection request to server after they are connected the PC and remote equipments or devices can be communicated each other In other words the PC can communicate with every KB2000 B The quantity of KB2000 B can be unlimited The system schematic structure as follow KingBird Shenzhen Kingbird network technology CO LTD KB2000 Data Converter for Internet Internet Server KB2000 A TCP IP TCP IP TCP IP TCP IP KB2000 B KB2000 B KB2000 B RS232 RS485 RS232 RS485 RS232 RS485 Device N Device 2 Device 1 6 2 KB2000 A Work with KB3000 KB2000 A can be network not only with KB2000 B but also KB3000 KB2000 A worked as Client side It is applied to single PC or multi PC system the single PC or multi PC can communicate with remote equipments or devices In this way KB2000 A is used as Client side When the host machine needs to communicate with remote equipments or devices KB2000 A will send TCP connection request to specified server and communicate after power on At the same time KB2000 B which con
9. king temperature 30 C 80 C Size 82mm L 59mm W 25 2mm H Weight 200g 9 Guarantee repair Our Company supplies three guarantees for repair replacement or compensation of faulty products But if it because force majeure user open or modify it himself without permission our company can not supply three guarantees User can replace products if he bought product within one month which installation and use regularly Guarantee repair free of charge period one year Maintain for life Packing list Item NO Name quantity unit memo 1 KB2000 1 Pcs 2 Power supply 1 Pcs 3 RS232 cable 1 pcs Provide only RS232 4 RS485 data line 1 pcs Provide only RS485 5 User manual 1 Pcs 6 Software CD 1 Disc
10. le for that equipment and PC software are serial communication mode and need for remote data communication projects Such as LED display information issue system and so on KB2000 Data Converter for Internet fi GPRS AppServer 1 28 Help Exit i Terminal Recora Supervisory Signal Target GPRS GPRSID_ SMID OnLine 00000000469 IA Groups TerminaiName _GPRSID__ __SIMID_ 00000000469 Add gt Delete clear Refresh Target Zone Protocol TCP TCP Connected Successfully Server No 1 Login network Successfully TCP A The system schematic structure as follow 12 KingBird Shenzhen Kingbird network technology CO LTD KB2000 Data Converter for Internet PC User monitoring software Appserver software Internet Server TCP IP TCP IP KB2000 B KB2000 B RS232 RS485 KB2000 B RS232 RS485 RS232 RS485 7 NOTE 7 1 If you choose manually get IP from configuration the IP must not have been used other KB2000 network device or PC 7 2 When the KB2000 connect with Switch or HUB please use direct cable when the KB2000 connect with PC please use Cross cable KingBird Shenzhen Kingbird network technology CO LTD KB2000 Data Converter for Internet 8 Technical specifications Buffer size 45K COM baud rate 300 115200bps Power supply 6 24VDC Average working electric current lt 6O0mA Power consumption lt 5 00mW Wor
11. nect with equipments or devices send TCP connect request to server after they are connected the PC and the remote equipments or devices can be communicate each other In other words the PC can communicate with every KB3000 The quantity of KB3000 can be unlimited The system schematic structure as follow KingBird Shenzhen Kingbird network technology CO LTD KB2000 Data Converter for Internet Data Server KB2000 A TCP IP LS rest eo KB3000 KB3000 KB3000 RS232 RS485 RS232 RS485 RS232 RS485 6 3 Appserver software With KB2000 B Appserver software is the client side communication software developed by our company and application in one single host or multi host system the single host or multi hosts in network need data communications with the equipment Appserver software can combine to use with user s device control software based on COM port it can obtain the data from user s device control software through COM part and send the data to the remote KB2000 B In this way when a host needs to communicate with device Appserver software send TCP connection request to designated server then communication with it At the same time the KB2000 B which connected with device sends the TCP connection request to server after connection established KB2000 B can communicate with server then user can use Appserver software in host communicate with every KB2000 B through server This network mode is very suitab
12. nzhen Kingbird network technology CO LTD KB2000 Data Converter for Internet 3 3 COM parameters Baud rate The data transmit speed User must set it same as PC or terminal device which connected The bard rate of KB2000 support from 300pbs to 115200pbs Data bits In COM port asynchronous transmission a group data real include data digit KB2000 support 5 8Bits data bits Data bits must be set the same as the PC or terminal device which connected In general it is 8bits Verify KB2000 s COM verify have three types None Even Odd User must set it same as PC or terminal device which connected Stop bits In COM port asynchronous transmission a data digit to indicate the end of this group data KB2000 support one and two stop bits User must set it same as PC or terminal device which connected In general the stop bits is 1bit Max MEM Time When KB2000 received data from COM port it will go into the buffer if over Max MEM Time and there are not next data come in KB2000 will transmit the data to the network Max MEM Bytes When KB2000 received enough length data from COM port KB2000 will transmit the data to the network KB2000 will transmit the data to network when it satisfies Max MEM Time and Max MEM Bytes in one of two conditions 4 Operation and Management Firstly user is advised to connect KB2000 with the same subnet through network cable by Switch or HUB and power on it User can set KB2000 User can Manage KB2000 with