Home

Quick Setup Guide

image

Contents

1. the ODU has reached is available in the Modulation Sub Channels Repetitions and FEC fields Operational Status Displays the radio link status Up or Down RSSI dBm the Receiver Signal Strength Indicator displays the received signal level CINR dB Displays the Carrier to Interference Noise ratio which indicates the radio link s signal quality In normal conditions CINR217 indicates a good signal quality Tx Power dBm ODU s transmit power 5 to 35dBm Default value is 5dBm Reduce the Tx power in case of short links making sure the RSSI at the remote ODU does not exceed 35dBm To view the loaded license configuration click Advanced Settings and then Licensing Check the currently enabled licenses features set and data rate To save the ODU s configuration click Save Configuration on the Web EMS Main screen Note If you do not click Save Configuration saving the currently running configuration to the startup A configuration all changes made will be lost upon the next ODU reset Support Contacts Contact your local distributor for the technical support Technical support for Siklu s direct customers e Siklu Support support siklu com e Siklu Support US amp Canada support us siklu com Download your copy of the EH 1200 Install and User Manual from ftp 85 17 162 140 user installmanual password siklu Watch us install and setup a link at www youtube com search Siklu Etherhau
2. EtherHaul 1200 1ft Antenna Sikl K Ul Quick Setup Guide P N IDOCO001 Rev A Description EH QSINST 01 issue 1 Safety Notes This Quick Guide is intended as a handy reference for setting up the EtherHaul 1200 ODU with integrated 1ft Antenna This guide does not replace the full manual please refer to the EH 1200 Install and User Manual for full installation and setup details The Installation and maintenance of this link should be performed by service personnel who are properly trained and certified to carry out such activities Make sure to disconnect all power cables before service ODU must be grounded using min 16AWG cable or according to local electrical code For DC 21 57 VDC connection use a 2 wire cable 14 18 AWG with 2 Amp circuit breaker on the live voltage or The other poly should be grounded Mounting 1ft Antenna Mount the ODU on a fixed reinforced steel mounting pole with 2 4 inches diameter Assemble the Mounting Bracket and attach it to the pole according to following diagram 1 Unit Mounting Screws and Bolts 2 Back Mounting Bracket 3 Front Mounting Bracket 4 Quick Release Plate Attached to ODU 5 Quick Release Hooks Azimuth Adjustment Lock Bolts Elevation Adjustment Lock Bolts 6 7 8 Azimuth Fine Adjustment Screw 8 9 Elevation Fine Adjustment Screw 16 10 Elevation Screw Tension Band and Pin Position the Azimuth and Elevation Adjustment Lock Bolts a
3. ay click System and then Route setting Index 1 Destination 0 0 0 0 Prefix Length 0 i Reset System save Configuration Next Hop gateway address Click Apply when finished To view and configure the Ethernet ports parameters click the interface icon on the main screen To configure the port for optical SFP set Ethernet Type to 1000xfd Click Apply when finished To view and configure RF parameters Click Radio Click Apply when finished Frequency MHz select from list default values is 74375 Channel Width MHz 250MHz or 500MHz Default value is 500 Role In a link one side must be set to Master and the other side must be set to Slave required for link synchronization Default value is Auto meaning the role will be set automatically by the link You can check the current set role in the Role Status field Manually setting the Role is necessary only for asymmetric configurations Transmit Asymmetry Default value is symmetric configuration 50 for Tx and Rx 50tx 50rx For an asymmetric configuration 75 25 or 90 10 you will have to manually configure the Role and set the Master unit to 75tx 25rx or 90tx 10rx and the Slave unit to 25tx 75rx or 10tx 90rx Mode Default value is Adaptive Adaptive Bandwidth Code and Modulation meaning the ODU will switch to the highest modulation profile available by data rate license and link condition In Adaptive mode the modulation profile
4. both ODUs by shortly pressing the ODU Reset Button This returns the ODU to Adaptive Mode ODU s default operational mode Following this action and after the ODU has finished rebooting the RF LED color indicator on both ODUs will turn Green indicating that the radio link is Up Carefully reinsert and tighten the AUX port protective seal The EtherHaul link can now pass traffic and management between the ports and over the radio link For further radio link configuration connect to the ODU using the Web EMS Basic Configuration Using Web EMS 1 Launch an Internet browser and enter the ODU s IP address in the address bar For the default IP address enter https 192 168 0 1 2 Wait for the Java Applet to load and enter the username and password default read write access admin admin 3 To view and configure system information click System and then System Information setting ODU Name Date YYYY MM DD and Time HH MM SS Click Apply when finished Note that changing the Date amp Time will terminate your connection and you will have to reconnect and launch the Web EMS To view and configure IP address click System and then IP setting Index 1 IP Address Prefix Length in mask bits VLAN 0O Click Apply when finished Note that changing the IP address will terminate your connection and you will have to reconnect and launch the Web EMS using the new IP To view and configure IP default gatew
5. ground cable to the ODU GND point 5 Power up the ODU using DC cable or 802 3at Power over Ethernet PoE connection available via RJ1 port only 6 In case of DC 21 57 VDC connect only the and wires to the DC terminal provided with the ODU Connectors Weatherproof Use the provided protective All Weather Shells as described in the following diagram fits cables from 3 5mm to 9 0mm diameter 1 Cable Inlet Portion 2 Rubber Gasket Insert 3 Connector Outlet Portion 4 Cable Thread the cable connector through the Cable Inlet Portion of the shell through the Rubber Gasket and through the Connector Outlet Portion Choose Rubber Gasket that best fits the cable diameter note the Rubber Gasket is spliced and can be assembled on cables with connectors Connect the cable connector to the ODU interface Screw the Connector Outlet Portion to the ODU firmly by hand do not use tools Insert the Rubber Gasket snugly into the Connector Outlet Portion of the shell Screw the Cable Inlet Portion to the Connector Outlet Portion firmly by hand do not use tools When removing All Weather Shell make sure to unscrew the Cable Inlet Portion first making sure the Connector Outlet Portion does not move and only then remove the Connector Outlet Portion from the ODU port System LEDs Blink Green Device boot 90 sec Red Power Failure bee ee re re eee ee eee ene eee meme
6. l Installation Siklu Communication Ltd 43 Hasivim St Petach Tikva 49517 Israel
7. t O degrees in the middle of the scale and unlock them to allow free movement during alignment Do not touch the radome when unpacking the ODU Do not rest the ODU face down to prevent scratches Prevent all contact between the radome and other objects Use care to avoid damaging or scratching the antenna radome S CAUTION By default the ODU is delivered with the Quick Release Plate attached in a vertical polarization If necessary change the ODU polarization by rotating the Quick Release Plate so the arrow will point the H horizontal mark on the back of the ODU Mount the ODU on the bracket using the Quick Release Hooks and slide it firmly inwards Stretch the Elevation Screw Tension Band slightly and connect it to its mating Tension Pin located on the Quick Release Plate Connecting the Cables 1 Electrical Ground Point GND 6 Ethernet Cable RJ45 Interface RJ2 2 Power Connector Interface PWR 7 Fiber Cable SFP Interface SFP2 3 DVM Probe Interface AUX 8 System LEDs 4 Ethernet Cable RJ45 Interface RJ1 9 Reset Button press for more than 5 seconds 5 Fiber Cable SFP Interface SFP1 to restore factory defaults 1 All cabling connected to the ODU should be outdoor grade with UV protection 2 Shielded outdoor Cat5e cables terminated with metallic RJ45 connectors must be used 3 Two Ethernet interfaces available and can be configured to either electrical RJ45 default or optical SFP 4 Connect the
8. wwe Off ODU off ETH1 2 Blink Green 1G activity Aligning the Antenna Perform a coarse Azimuth and Horizontal alignment using a line of sight visual check with the remote ODU Lock the Mounting Bracket to the pole using a 13mm 0 5 open wrench Once ODU is powered up switch both ODUs to Alignment Mode by inserting the Digital Volt Meter probes into the DVM Probes at the AUX Interface Following this action the RF LED color indicator will turn orange indicating the ODU is in Alignment mode The ODU will remain in Alignment Mode even if the DVM probes are ejected until the ODU is rebooted Read the receive level RSSI using the DVM The voltage reading will be between 0 to 1Vdc indicating the RSSI in dBms for example 0 45V 45dBm Perform fine Azimuth and Elevation alignment using the fine adjustment bolts identifying the main lobe until the expected receive level is achieved within 4dB Once the optimum position has been achieved tighten the azimuth adjustment lock bolts on one ODU first Tightening the azimuth adjustment lock bolts will tilt the ODU so realign the elevation again for optimum position and then tighten the elevation adjustment lock bolts Use the DVM to verify that the received signal level has not changed on ODU after final tightening of the brackets Repeat steps 5 7 on the second ODU Antenna alignment is now complete Initial System Setup Disconnect the DVM and reboot

Download Pdf Manuals

image

Related Search

Related Contents

  Impex PWR 6 User's Manual    資料4-4 情報流通連携基盤システム外部仕様書(version 2.0)(PDF)  Operating instructions  Manual de Instruções  Trendnet Gigabit PCI  Cables Direct 0.3m USB/3.5mm DC  LOK-IT User Guide  TA 機能付ネットワークステーション(FMNS-101)  

Copyright © All rights reserved.
Failed to retrieve file