1. Please refer to 1 3 2 Camera angle adjustment regarding adjust camera angle 3 Re assemble the camera Wall mount Ceiling mount Wrench 1 4 4 Electric Specification Classification Specification Power Supply Regulated 12V DC PoE Power over Ethernet IEEE802 3af Current Consumption Max 1A DC 12V IRLED ON Operation Temp 45 C 50 C Dimension 121 2 W x 91 7 H mm Weight Approx 450g 1 3 2 Camera angle adjustment 1 Pan adjustment Graso the disk of camera and then adjust direction to the right or left 180 180 2 Tilt adjustment Grasp the camera holder of camera and then adjust direction to the up or downl 90 3 Roll adjustment Grasp the camera holder and then rotate 178 178 Caution If you try to adjust the camera out of limited angle it might cause troubles and damage to camera DISK CAMERA HOLDER 1 3 3 DIMENSION 1 4 7 Basic Setting Table Default Basic setting Remarks Network Static IP Dynamic IP Static IP IP Server Enable Enable IP Address 192 168 1 30 Gateway 192 168 1 1 Subnet Mask 255 255 255 0 Web Connection Port 80 RTSP Port 554 RTP Port Range 5000 5999 ID and Password Administrator ID Password admin admin User ID Password root root guest guest Domain of Related Server iplinker net Stream setting Stream 1 H 2
2. 2 MEGA PIXEL NETWORK DOME CAMERA SK NV821 SERIES QUICK GUIDE 1 4 Specification 1 4 1 Camera Specification Model No SK NV821 Type Megapixel network dome camera Image Sensor 1 2 8 SONY PROGRESSIVE EXMOR CMOS Effective Pixels 1984 H x 1225 V Resolution 1920x1080 1280x1024 1280x960 1280x720 1024x768 960x540 640x480 640x360 320x240 Scanning System Min Illumination Progressive Scan LED OFF 0 01Lux LED ON OLux 25M Range 24PCS 1 4 2 Camera Function ee Privacy Zone Fixed focal lens ON OFF 6 Programmable Zones Day amp Night WDR Auto Night Day WDR 1 5 Back Light Front Light Function Electronic Shutter Sense Up Auto 1 25 1 5 000 NTSC 1 12 5 1 8 000 PAL Suppress Rolling Manual Auto 1 14 White Balance Auto Indoor Outdoor Fluorescent User Chapter 1 Install and Specification 1 1 Safety Cautions 1 This camera may be damaged by electrical and physical shock Use regulated 12V DC 1A power supply Do not throw or drop it onto floor 2 In case it is installed at high location be sure to mount securely to prevent the unit from falling below 3 In case the unit fails Do not try to disassemble the product Contact or consult the distributor or an authorized technician for after sales service Warranty void for the product disassembled without an authorization from the distributor or an author
3. 64 30fps 1920x1080 rtsp lt ip address 554 streamt Stream 2 rtsp lt ip address 554 stream2 Stream 3 None rtsp lt ip address 554 stream3 Video out OFF After installation deactivate it Reference In case to reset hardware and network setting ID and password of user and Administrator will be automatically retumed to the above default value Frame rate can be affected by the external video output option So factory default is off When you install the camera enable this option Then disable it after the installation DDNS Server Chapter 2 Installation and Video Check 2 1 Installation On the assumption that User PC and the camera are used under static IP and the camera is to be directly connected with User PC or Local Network The installation procedure is to be 1 Connect the camera and PC with LAN Cable 2 Power on camera Use regulated 12V DC 500mA or 1A Built in IR LED Model X Use PoE Power Over Ethernet The cable includes data and power so it s easy to install the camera So you can save time to install and cost When you connect the camera with PoE and DC adaptor Only PoE is used 3 Wait about 2 minute after power on camera the system will be booted 2 2 Network Setting and Video Check Default network setting value of the unit is to be N IP Address 192 168 1 30 Subnet Mask 255 255 255 0 Gateway 192 168 1 1 To connect the unit in user s PC change the setting
4. fort PA A O Q QOW O tem Description S Select stream codec and resolution menu related to Stream selection jive view was defined only by the admin H 264 MPEG MJPEG Default size is 640X480 Adjust the screen to the optimal size Recommendation Select the same size with stream resolution Window size Connection Disconnection Connect or disconnect to the stream Recording Saves the stream as a moving picture file in the avi format Saves the snapshot as an image file in the omp format Specify the file saving path Camera name Display camera title Date Display the date OTime Display current time Capture Saving path Display the site information such as Day Night Motion Status Icon Alarm input output Display the stream information such as Audio and Stream Info recording condition 12 3B26343A
5. ized technician 4 All responsibility by using this unit is on the user lf the product is to be put out of operation definitively take it to a local recycling plant for a disposal which is not harmful to the environment a 9 1 2 Package Ss Quick Guide zg Software amp User Manual CD a A A O Git 1 4 3 Network Specification Classification tem Specification Embedded Linux OS Network Interface RJ45 10 100BaseT Ethernet Setting By web browser Leased Line Cable Modem Support Dynamic Network Support IP and Static IP ADSL usable under Router Summary TCP IP UDP IP RTP RTSP RTCP NTP Supported Protocol TTP DHCP FTP SMTP DNS DONS Security User authentication PC OS WINDOWS XP WINDOWS VISTA WINDOWS 7 Compression H 264 MPEG 4 MJPEG Resoun 1920x1080 1280x1024 1280x960 1280x720 1024x768 960x540 640x480 640x360 320x240 Image Compression Rate 200 1 Typical Frame Rate Max 30fps 1920X1080 Bit Rate 64 9000kbps Simultaneous Access Max 10 users Video Recording Recording in client PC with CMS or FTP Server Motion Detection Support Function Privacy Zone Support OSD Support Dynamic IP Support IP Router Support DDNS Support 1 3 HOW TO INSTALL 1 3 1 Camera installation 1 Fix the camera set with the supplied screws on ceiling or wall mount If you don t use supplied screws the camera may fall off 2
6. k on Viewer to see the video feed Default administrator s ID amp Password is admin lt Caution Please change default value of ID Password into new ones after the installation Reference Please refer to 5 3 Administrator s ID and Password Change regarding Change Administrator 2 2 4 Active X auto installation Click install on the security certificate to load the Active X control lf you choose Dont install the web viewer would not work http 192 168 1 8 cai bin view_cam cai This website wants to install the following add on viewcam from samhyunelectronics If you trust the website and the add on and want to install it dick here To display the webpage again Internet Explorer needs to i resend the information you ve previously submitted If you were making a purchase you should click Cancel to avoid a duplicate transaction Otherwise click Retry to display the webpage again cone xi Do you want to install this software a Name viewcam Publisher samhyunelectronics met i While files from the Internet can be useful this file type can potentially harm Wey your computer Only install software from publishers you trust What s the risk x More options 11 2 2 5 Complete the installation Upon installation Web Viewer appears and image of camera is to be seen Q Megapixel Network camera For your safety and com
7. value of PC network environmert lt Caution Before changing the setting value please memorize the previous setting value on your PC MEMO X The specification is subject to change without any prior notice to improve the quality 2 2 1 Change the setting value of PC network environment Set IP Address Subnet Mask and Gate way of user s PC with 192 168 1 50 255 255 255 0 192 168 1 1 as shown on below picture internet Protocol TCPAP Properties General You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings Obtain an IP address automatically Use the following IP address IP address Subnet mask Default gateway Use the following DNS server addresses Preferred DNS server 168 Altermate DNS server Advanced OK J Cancel 2 2 2 Connect the camera with web browser Run web browser and input the default IP address 192 168 1 30 in URL line and press Enter Then below picture is to be shown 2 Web Manager for Camera Windows Internet Explorer g le 192 168 1 30 Web Manager for Camera Megapixel Network camera For your safety and comfort ID Password Viewer S Manager B Y X If the page does not open Please refer to Chapter 11 appendix in the CD 10 2 2 3 Input ID Password Shown the main page input ID and Password and clic