Home
setup information
Contents
1.
2. DATA RECEPTION FROM TX PULSE ATEX 800 010 WITH FCT SOFTWARE m S With FCT software you will be able to check that data from TX PULSE ATEX 800 010 are received correctly by RX USB or RX MODBUS Receiver Click on Stop configuration Then click on View network You will see data from the TX PULSE ATEX 800 010 displayed on FCT software gt EEE EEE EEE Enless Wireless x Search by ID Confi ti i Expert Wireless M2M Bibi ose Search Device Type Time Device ID Data 1 ID Data 1 Data 2 ID Data 2 RSSI dBm Battery TX PULSE 19 juin 15 12 01 45 11300138 CSTD Pulse Count 1 0011 0 CSTD Pulse Count 2 0011 0 41 0 OK T PULSE 19u15 12 00 44 11300138 CSTD Pulse Count 1 0011 O CSTD Pulse Count 2 001170 410 OK CSTD Pulse Count 1 0011 0 CSTD Pulse Count 2 0011 0 410 OK DEVICE TYPE TX PULSE TIME Date amp Time of data transmitted by TX PULSE ATEX 800 010 DEVICE ID Unique 8 digit address from TX PULSE ATEX 800 010 DATA 1 ID Pulse count 1 DATA 1 Data received by the receiver DATA 2 ID Pulse count 2 DATA 2 Data received by the receiver RSSI SIGNAL Radio signal strength dBm between TX PULSE ATEX 800 010 transmitter and RX USB or RX MODBUS Receiver gt from 10 to 50 dBm excellent radio quality signal gt from 50 to 85 dBm good radio quality signal gt from 85 dBm and lower low radio quality signal BATTERY Level of battery
3. 800 010 AND RECEIVER Fit battery in its compartment Pull out the paper which isolate the battery from the connector LED indicators L1 L2 amp L3 will blink simultaneously L1 will blink every 3 seconds TX PULSE ATEX 800 010 is now entering configuration installation mode TX PULSE ATEX 800 010 will try to connect to the RX USB or RX MODBUS Receiver during 1 minute maximum If LEDs don t blink when inserting the battery and pulling out the paper remove the battery from its compartment and try again If TX PULSE ATEX 800 010 is within the range of RX USB or RX MODBUS Receiver successful installation configuration messages as well as RSSI Radio signal strength will be displayed in the message window of FCT software The combination of L1 L2 and L3 LED indicators will confirm success or failure of the installation See below L1 L2 and L3 LED INDICATORS COMBINATION SUCCES OF INSTALLATION L2 amp L3 LED indicators will remain ON for 30 seconds confirming the success of the installation Transmitter is connected to RX USB RX MODBUS Receiver Transmitter will then switch to communication mode It will send its data at defined periodicity 5 minutes default periodicity L1 LED indicator will blink every minute L2 LED indicator will blink every time data will be sent from the transmitter to the receiver SUCCESS OF THE INSTALLATION BUT LOW RSSI SIGNAL L1 L2 amp L3 LED indicators will remain ON for 30 seconds confirmin
4. INSTALLATION GUIDE TX transmitter for gas meters with pulse interface TX PULSE ATEX 800 010 868 MHz IG UK 800 010 a Enless Wireless Fl M2M amp loT Wireless Expert 33 0 5 56 35 97 47 contact enless fr www enless fr DECLARATION CE DE CONFORMITE EC DECLARATION OF CONFORMITY CE Enless Wireless We _ Enless Wireless 45 ter avenue de Verdun 33520 Bruges France Declare under our sole responsibility that the product Designation Radio transmitters Product Name s amp References TX PULSE ATEX 800 010 Attestation LCIE 14 ATEX 3013 X Notifi e par le LCIE 33 avenue du G n ral Leclerc 92260 Fontenay aux Roses France Num ro LCIE 0081 To which this declaration relates satisfy the provision of Directive ATEX 94 9 EC of the European parliament and the council of 23 March 1994 is in conformity with the following standard s or other normative document s e EN60079 0 2012 EN60079 11 2012 The marking is II 1 G Ex ia IIC T3 Ga Fulfill the directives amp standards RTTE 99 5 EC of 9 March 1999 RoHS 2011 65 EU of 1 July 2011 EN300 220 1 amp 2 V2 4 1 2012 05 EN301 489 1 V1 9 2 2011 09 EN 301 489 3 V1 4 1 2002 08 EN 60950 1 2006 A11 2009 A12 2011 AC 2011 EN 5081 2012 EN61000 4 2 2009 Date 05 05 2014 Bruno Petit G rant REMINDER REGARDING INSTALLATION OF TX PULSE ATEX 800 010 Referring to ATEX Directive 1999 92 CE only operators tra
5. e Define periodicity retry pulse count 1 and pulse count 2 Tx Pulse Tx Time 1 to Address 250 min Re try 0 1 Pulse Counti Pulse Count 2 11200039 5 0 0 0 Then click on OK to add these transmitters to your configuration file 9 Click on Start Configuration You can now install the TX PULSE ATEX 800 010 transmitter INSTALLATION OF TX PULSE ATEX 800 010 CONNECT TX PULSE ATEX 800 010 TO THE METER TX PULSE ATEX 800 010 is provided with 4 wires allowing connection up to 2 meters Meter 1 input 1 Input 1 wires are labeled A and A A is connected on terminal block to PULSE 1 INP A is connected on terminal block to GND Meter 2 input 2 Input 2 wires are labeled B et B B is connected on terminal block to PULSE 2 INP B is connected on terminal block to GND Length of the wires 150 cm You should avoid extending the length of these wires because of potential interferences which could generate wrong pulses INSTALL TX PULSE ATEX 800 010 e oet TX PULSE ATEX 800 010 at least 1 5 meter above the ground e Install TX PULSE ATEX 800 010 v Wall mounting with 2 brackets or v Collar mounting with 2 brackets or v DIN Rail adaptor to be fitted at the back of the transmitter enclosure TX PULSE ATEX 800 010 must always be installed with antenna upwards OPEN TX PULSE ATEX 800 010 ENCLOSURE Open the lid using the 4 screws START RADIO COMMUNICATION BETWEEN TX PULSE ATEX
6. g the success of the installation Transmitter is connected to the RX USB or RX MODBUS receiver However L1 LED ON confirm that the RSSI signal is low 85 dBm or less Message FCT Installation is successful for Transmitter address Transmitter will then switch to communication mode It will send its data at defined periodicity 5 minutes default periodicity L1 LED indicator will blink every minute L2 LED indicator will blink every time data will be sent from the transmitter to RX USB or RX MODBUS receiver FAILURE OF THE INSTALLATION After 1 minute the transmitter failed to connect to RX USB or RX MODBUS receiver L2 amp L3 LED indicators will blink for 30 seconds meaning the transmitter is not within the range of RX USB or RX MODBUS receiver There is no message displayed on FCT software Transmitter will then switch to communication mode It will try to send its data at defined periodicity L1 LED indicator will blink every minute L2 LED indicator will blink every time data will be sent from the transmitter to RX USB or RX MODBUS receiver In case of installation failure Move the RX USB or RX MODBUS receiver antenna in order to optimize radio propagation e Move the transmitter if you can and try the procedure again If the problem remains you will have to install a repeater between transmitter and RX USB or RX MODBUS receiver CLOSE TX PULSE ATEX 800 010 ENCLOSURE Close the lid using the 4 screws CHECK
7. ined for risk areas are allowed to install TX PULSE ATEX 800 010 No changes to TX PULSE ATEX 800 010 are allowed Special conditions for a safe installation TX PULSE ATEX 800 010 shall only be connected to intrinsically safe certified equipment This combination must be compatible as regard intrinsic safety rules Uo lo Po Co Lo specified on TX PULSE ATEX 800 010 label Certifications TX PULSE ATEX 800 010 is ATEX certified lt Ex gt Il 1G Ex ia IIC T3 Ga 20 C lt Tamb lt 55 C LCIE 14 ATEX 3013 X Uo 3 9V lo 900mA Po 153mW Co 63uF Lo 44uH TX PULSE ATEX 800 010 complies with standards EN60079 0 et EN6079 11 Battery TX PULSE ATEX 800 010 is delivered with ER14505 battery Only ER14505 battery can be used with TX PULSE ATEX 800 010 Contact details for supplying ER14505 battery Enless Wireless 45 ter avenue de Verdun 33520 Bruges France Telephone 33 0 5 56 37 97 47 E mail contact enless fr WARNING DANGER POTENTIAL ELECTROSTATIC CHARGES TX PULSE ATEX 800 010 must only be cleaned with damp rag DESCRIPTION TX PULSE ATEX 800 010 Transmitter designation and reference Radio frequency Transmission periodicity Retry Device ID CONFIGURATION OF THE TX PULSE ATEX 800 010 FCT Field Configuration Tool software allows installation of the transmitters and configuration of RX MODBUS Receiver Please refer to user manual available on www enless fr 1 Pos
8. ition your laptop PC to the place where you intend to install the RX USB or RX MODBUS receiver FCT software is running on your PC 2 Connect the RX USB or RX MODBUS receiver to the USB port of your PC If you are using RX MODBUS Receiver for the installation of the transmitters switches DIP 1 amp DIP 2 must be configured the following way e DIP1 switches 5 amp 6 ON all other switches OFF e DIP2 switches 1 2 amp 3 OFF Please refer to FCT manual for the complete installation of RX MODBUS Receiver 3 Fit the antenna on RX USB or RX MODBUS SMA connector 4 Start FCT software on your PC Select English and type your user name Enless Wireless Expert Wireless M2M Enless Field Installation v2 1 Please enter your name to continue Enless 5 Click on Refresh list The USB COM Port you have connected the receiver to will be selected 6 Click on Connect The receiver is now connected to the PC ready to receive data from TX PULSE ATEX 800 010 Ss Connect Message in the dialog box Serial Port Connected COMx xxxxx 7 Select the family of the transmitters you want to install For this product you have to select lt Tx Pulse gt tab then click on Edit View j s 35 Edit View A new window will open 8 Click on this button to add the TX PULSE ATEX 800 010 transmitter e Fill in the ID in the Address field Important this ID is composed of 8 numbers
Download Pdf Manuals
Related Search
Related Contents
Terms and conditions for the servicing of payment cards IS 7032-1 to 8 (1986): Physical methods of test for uncut Indian jute User Manual - Micro Solve LogiLink PC case cooler Intel Server Systems SR2520SAFR Niles Audio AT8000 User's Manual Screw Fastening System Attachment Philips docking speaker with Bluetooth® AD620 Samsung AP55Q2BN User Manual Hybrid E Copyright © All rights reserved.