Home

HY3000sei Manual - Hyundaipower.ca

image

Contents

1. Visually inspect the spark plug Clean the spark plug with a brush if it is to be reused 6 The spark plug clearance gap should be between 0 7 mm 0 8 mm 0 028 to 0 03 refer to fig Te Install the correctly gapped spark plug back into the original position 20 HY3000sei User Manual HYUNDAI 0 6 0 7mm F 0 024 0 028in 8 Reinstall the ignition coil securely 9 Close the top maintenance cover and tighten the screw TRANSPORTATION AND STORAGE 1 Do not overfill the tank 2 Before attempting to transport allow generator to cool for at least 15 minutes 3 To prevent fuel spillage the generator should be secured upright in its normal operating position with the start switch in the STOP position 4 Do not drop or strike the generator when transporting 5 Do not place heavy objects on the generator WARNING e Gasoline is extremely flammable and explosive under certain conditions e Do not smoke or allow flames or sparks in the area STORAGE PROCEDURE 1 Drain fuel remove gas tank cap remove fuel filter and syphon fuel into an appropriate gasoline container Rotate fuel valve to the open posi tion and allow any remaining fuel to drain into the pot fefer to fig 2 Start the generator and allow fuel remaining in carburetor bowl to be used Once the generator shuts off it can be stored 3 To drain oil HY3000sei User Manual 21 HYUNDAI Set the start switch to the STOP position and make s
2. Manual 15 HYUNDAI DISCONNECTING THE CHARGING WIRE 16 1 2 Stop the engine Disconnect the negative black terminal of charging wire from the negative battery terminal Disconnect the positive red terminal of the charging wire from the positive battery terminal Disconnect the charging wire from the DC Receptacle of the genera tor HY3000sei User Manual HYUNDAI MAINTENANCE Proper maintenance is important because it will ensure safe economical and trouble free operation It will also reduce air pollution Improper maintenance may cause the generator to malfunction and can lead to serious injuries MAINTENANCE SCHEDULE WARNING e Shut off the engine before performing any maintenance When the engine is running make sure the area is well ventilated e If you require a part for replacement we strongly recommend using Hyundai OEM replacement parts Do not use non Hyundai parts Contact customer service for replacement parts e Some of these maintenance techniques can be dangerous and should be performed by a qualified technician To ensure long lasting durability and performance be sure to inspect and main tain your generator based on the schedule below EACH 1 MONTH 4 MONTHS 6 MONTHS YEARLY ITEM ACTION USE 20HRS SOHRS 100 HRS 200 HRS Check Level e ENGINE OIL Change e e Check e AIR FILTER e Clean REFER TO NOTICE 1 Check
3. by operation of the gen erator set in a marine application 6 Damage caused by operation with improper fuel or at speeds loads conditions or modifications contrary to published speci fications 7 Items not supplied by Hyundai including but not limited to starting batteries battery cables external wiring fuel lines fil ters etc refer to exclusions 8 Repairs made during the warranty period without first obtaining a case number from Hyundai Batteries supplied with any generator product should be considered a bonus item and not covered by warranty Batteries can be damaged by shock shorting terminals heat acid spillage and a number of other factors that cannot be con trolled after they have left our facility It is the customer s responsibility to take great care when handling a battery so no spillage of acid will occur and cause corrosion damage caused by battery acid is not covered under this warranty HY3000sei User Manual 29 HYUNDAI Product Registration Product registration is required for product support and warranty coverage The owner s registration found in the user manual can be completed and mailed You can also register online at www hyundaipower ca You should keep your receipt for proof of purchase Warranty Claim Procedure Warranty service must be performed by one of our authorized service dealers If you feel your generator is malfunctioning due to a defect or misuse simply contact our cust
4. e SPARK PLUG Replace e e VALVE CLEARANCE Check REFER TO NOTICE 2 COMBUSTION CHAMBER Clean EVERY 300 HOURS e FUEL TANK ci AND FILTER san REFER TO NOTICE 2 FUEL LINE Clean EVERY 2 YEARS REPLACE IF NECESSARY REFER TO NOTICE 2 ale Service more frequently when used in dusty areas 2 Should be serviced by an authorized dealer HY3000sei User Manual 17 HYUNDAI AIR FILTER SERVICE A dirty air cleaner will restrict air flow to the carburetor To prevent carburetor malfunction service the air cleaner regularly Service more frequently when operating the generator in extremely dirty areas T 2 8 4 Loosen cover screws and remove the maintenance cover Remove air filter cover Remove air filter sponge refer to fig Check air filter sponge to make sure it is clean and in good condition Clean sponge if dirty refer to fig Replace sponge if damaged Air Filter Sponge Maintenance Cover Air Filter Cover Screws To clean the sponge e Clean air filter sponge in warm soapy water or non flammable detergent Allow to dry before reinserting into generator e Dip sponge in clean engine oil and squeeze out all excess oil The engine will produce excess smoke if too much oil is left in the filter e Wipe dirt off the air filter cover using a moist rag CHANGING THE ENGINE OIL 1 18 Set the start switch to the STOP position and make sure the fuel cap is fully closed Loosen the cover s
5. GREENPOWER g3 PORTABLE INVERTER USER MANUAL HYUNDAI POWER EQUIPMENT LICENSED BY HYUNDAI CORPORATION KOREA PRINTSPEC EN3000sei 2013v1 2013 MIDLAND POWER INC Thank you for purchasing this Hyundai GreenPower portable inverter generator Please register your product in order for us to ensure your continued satisfaction This manual covers the safety operation and maintenance procedures for the HY3000sei All information in this publication is based on the latest product information available at the time of approval for printing No part of this publication may be reproduced without written permission If a problem should arise please contact us by using the contact information at the end of this manual It is important that this manual be read and fully understood before operating the generator set Failure to do so may cause serious injuries or equipment damage and may void the warranty CONTENTS Safety Precautions AC Safety Guidelines Identification of Components Pre operation Inspection Fuel Level Check Air Filter Check Operation Using the Generator AC Operation DC Operation Stopping the Generator Maintenance Troubleshooting Specifications Warranty Glossary HYUNDAI SAFETY PRECAUTIONS This generator is designed to give safe and dependable service if operated according to instructions Read and understand this manual carefully before operating the generator failure to follow instruct
6. HY3000sei User Manual 35 HYUNDAI 36 HY3000sei User Manual HYUNDAI HY3000sei User Manual 37
7. PLIED 28 HY3000sei User Manual HYUNDAI Consumable parts such as oil or fuel filters fuel cut off valve brushes fuel injection nozzle valve lubricant or ignition plug are not covered under this warranty All expenses incurred in maintaining and replacing parts for generator shall fall on the purchaser This warranty coverage does not include parts af fected by accident and or collision corrosion or rust normal wear incorrect fuel type or fuel contamination use in an application for which the product was not intended unauthorized service or any other misuse neglect incorporation or use of unsuitable attachments or parts Damage to voltage regulators caused by failure to ground shorting or overloading will not be covered under this warranty Under this Warranty we do not have the obligation to bear any transportation fees of any product to from an authorized Warranty Center Unauthorized altera tion installation or any cause other than defects in material or workmanship of the product will not be covered under the warranty EXCLUSIONS NOT COVERED BY THIS LIMITED WARRANTY 1 Normal engine alternator wear 2 Damage caused by lack of maintenance as described in the Hyundai manuals or negligence by using improper or impure motor oil coolant or fuel 3 Damage caused by accidents improper installation or storage 4 Damage caused by water ingestion submersion or external water damage 5 Damage or non performance caused
8. anual HYUNDAI PROBLEM SYMPTOMS CORRECTION Generator Generator 1 The on off switch is in the Off position will not will not start Switch to On start 2 The engine is out of gasoline 3 Engine choke is in wrong position Adjust choke lever according to instructions on page 12 4 Fouled spark plug replace with equal or greater quality plug Refer to page 27 in your user s manual for a complete list of spark plug compatibility codes 5 Insufficient oil add more oil 6 Clogged fuel line inspect gas tank for debris High resis 1 The engine does not have enough oil tance when add oil pulling recoil 2 Air filter element obstructed by debris starter Clean according to user manual instruc tions on page 18 Difficulty Engine re 1 Disconnect load before starting starting quires many 2 Incorrect oil being used Please refer to the attempts to oil usage chart on page 27 in your user s start manual 8 Fouled spark plug replace with equal or greater quality plug Refer to page 27 in your user s manual for a complete list of spark plug compatibility codes Generator Noindicator 1 Generator circuit breaker off or tripped does not lights or 2 Remove all loads reset breaker and check produce display on device for defects Do not exceed generator power front panel rating HY3000sei User Manual 23 HYUNDAI Overload il Adjust choke lever accordin
9. ce inserted in the head of an internal combustion engine cylinder which ignites the fuel mixture by means of an electric spark 32 HY3000sei User Manual HYUNDAI OWNERSHIP AND WARRANTY TRANSFER INSTRUCTIONS Changes in ownership must be registered with Hyundai Power Equipment in order to ensure continued warranty and service support Warranty support cannot be provided without registration from original date of purchase and after transfer of ownership This transfer form must be completed on or before the date that ownership change takes effect Warranty coverage continues from original date of purchase and is not extended by transfer of ownership HYUNDAI Transfer of Ownership and Warranty Card Existing Owner Information First Name Last Name Company Street Name and Number City Postal Zip Code Province State Phone Number Other Contact Number Fax Number Email New Owner Information First Name Last Name Company Street Name and Number Giy Postal Zip Code Province State Phone Number Other Contact Number Fax Number Email Product Information The serial number can be found on the Generator or on the exterior of the packaging Model Name Serial Number E Initial Date of Purchase Warranty Expiration Date of Transter Add 2 years to initial date of purchase NOTE Transfer of ownership does not act as a warranty extension The original 2 Year Warranty is effective as of the Ini
10. crews and remove the maintenance cover Place a container next to the engine to catch the used oil refer to fig Remove the oil filler cap dipstick and drain the oil into the container by tilting the generator HY3000sei User Manual HYUNDAI 5 With the engine in a level position add oil to the upper level mark refer to fig Upper limit Dipstick Oil Filler Cap Lower limit 6 Reinstall the oil filler cap dipstick securely T Reinstall the maintenance cover and tighten the cover screws securely WARNING e Make sure the start switch is in the STOP position before drain ing e Please dispose of used motor oil in a manner that is compatible with the environment We suggest you take it in a sealed con tainer to your local service station for reclamation Do not throw it in the trash or pour it on the ground e Do not use gasoline for cleaning since it is flammable and explo sive under certain conditions HY3000sei User Manual 19 HYUNDAI SPARK PLUG SERVICE To insure proper operation the spark arrester should be cleaned thoroughly at least once every 100 hours of use Top maintenance cover 1 Remove the top screw and the top maintenance cover refer to fig 2 Remove the ignition coil refer to fig 3 Clean any dirt and debris around the spark plug base Spark Plug Wrench Ignition Coil DC Wire High Voltage wire Spark Plug 4 Use a wrench to remove the spark plug refer to fig 5
11. device to the generator make sure the elec 12 HY3000sei User Manual HYUNDAI trical rating of the device does not exceed the electrical rating of the generator e Be sure the device is turned off before plugging in the power cord e When the output indicator light green is OFF and the overload indicator light red is ON flip the engine switch to the STOP position stop the engine at once and then start the engine again NOTICE When a connected device draws high startup power the overload and output indicator light may briefly illuminate but this is to be expected Once the device starts up the overload indicator light will shut off and the output light will remain green GROUND TERMINAL Before using the generator a ground wire must be connected to the ground terminal Before using the ground terminal consult a qualified electrician Refer to Fig FOR AC OPERATION dE Ensure all devices are OFF before connecting to the generator 2 Start the generator and make sure that the green output indicator light turns on Refer to Fig 8 Plug the power cord of the device into the AC socket turn on the circuit protector and turn on the device Refer to Fig HY3000sei User Manual 13 HYUNDAI NOTICE Under normal operating conditions the output indicator light Green will be ON If the generator is overloaded in excess 100W or if there is a short circuit in a connected device the overload indicator light R
12. e serious injuries to workers during power outages When the utility power is restored the generator may explode or cause fires Place generator at least 1 m 3 ft away from buildings or other equip ment during operation Operate the generator on a level surface Tilting the generator may result in fuel spillage Know how to stop the generator quickly and understand the operation of all controls Never permit anyone to operate the generator without understanding the proper instructions HY3000sei User Manual 5 HYUNDAI Do not operate the generator in rain or snow or allow any moisture to come in contact with the generator Do not touch the spark plug while the generator is operating and shortly after the generator has been shut down Keep children away from the generator when it is in use AC SAFETY GUIDELINES Before connecting the generator to an electrical device or power cord Make sure that everything is in right working order Faulty devices or power cords can lead to an electrical shock Turn off the generator immediately if the device begins to operate abnormally Then disconnect the device and investigate the problem Make sure that the electrical rating of the device does not exceed that of the generator If the power level of the device is between the maximum output power and the running power of the generator the generator should not be used for more than 30 minutes The connections from the generator to the hou
13. ed will be ON Substantial overloading that continuously lights the overload indicator light red may damage the generator Marginal over loading that temporarily lights the overload indicator red may shorten the service life of the generator If the oil level falls below a safe limit the low oil indicator light Red comes on and the engine will be automatically stopped If the engine stops or the low oil indicator light comes on when you pull the starter grip check the engine oil level before trouble shooting in other areas Refer to Fig Output Overload Low Oil Surcharge Pret A Utiliser Huile Bas 7 N IN A FOR DC OPERATION Do not leave generator unattended when charging batteries Stop charging when the voltage of the batteries is above 16V Failure to monitor charge level may result in damage to the battery or personal injury The DC receptacle may be used while the AC power is in use The overloaded DC circuit will trip the DC circuit protector If this happens dis connect the DC load before pushing in the circuit protector to resume operation Set the ECON switch to the OFF position Connecting the battery charging cable 14 A 2 gt Connect the battery charging cable to the battery Plug the charging wires into the DC outlet of the generator Connect the positive Red terminal of the charging wire to the positive battery terminal and negative b
14. g to instruc indicator tions on page 12 light keeps When a connected device draws high startup flashing power the overload and output indicator light may briefly illuminate but this is to be expected Once the device starts up the overload indicator light will shut off and the output light will remain green 2 Ensure device wattage consumption does not exceed the generator s maximum peak output No DC 1 Disconnect battery reset breaker and test output the battery for shorts 2 Clean battery connector nodes Generator Connected Verify device start up requirements Wattage outputs device does consumption Do not exceed the generators unstable not operate maximum peak output power consistently Device will 1 Remove all loads reset breaker and check not start up device for defects Do not exceed genera tor rating 2 Ensure device s wattage consumption does not exceed the generator s maximum peak output Engine idle Carburetor in need of tuning For details on how unusually to adjust correctly please contact your local high or low service centre or contact Midland Intl Inc at 1 877 528 3772 Generator Operation is LE Atmospheric temperature high excess overheats normal when of 35 C generator is 2 Insufficient air circulation in vicinity of cool over generator heating oc 3 Low oil viscosity use 10W40 when curs within temperatures exceed 30 C 10W30 for moments of temperatures between 0 30 C and start
15. ions could result in serious injury or death Engines give off carbon monoxide an odorless colorless poison gas Breath ing carbon monoxide can cause nausea fainting or death Do not operate the generator indoors or in a confined area and make sure the working environment is well ventilated The exhaust and muffler becomes very hot during operation and remains hot for a while after stopping the engine Make sure to read all warning labels Be careful not to touch the muffler while it is hot Let the engine cool before storing the generator indoors When storing gasoline or equipment with fuel in tank Store away from furnaces stoves water heaters or other appliances that have a pilot light or other ignition source because they can ignite OPERATING INSTRUCTIONS Operate the generator according to instructions for safe and depend able service Always perform a pre operation inspection before starting the engine Properly clean and maintain the equipment Make sure to read and understand all warning labels Gasoline is a highly flammable and explosive liquid Make sure to refuel in a well ventilated area with the engine stopped When refuelling the generator keep it away from cigarettes open flames smoke and or sparks Connections for standby power to a building s electrical system must be done by a qualified electrician and must comply with all applicable laws and electrical codes Improper connections may caus
16. lack terminal of the charging wire to the negative battery terminal Turn the start switch to the ON position Set the DC breaker switch to ON position refer to fig Start the generator HY3000sei User Manual HYUNDAI NOTICE e The DC socket is only used for charging a 12V battery refer to fig e When using the DC socket turn the ECON switch to the OFF position refer to fig WARNING e The battery gives off explosive gases keep sparks flames and cigarettes away Provide adequate ventilation when charging or using batteries e Battery posts terminals and related accessories contain lead components Wash hands after handling STOPPING THE GENERATOR SET FOR AC OPERATION is Turn off the device and unplug devices from the generator recep tacles 2 Turn the start switch to the STOP position 3 Rotate the fuel switch to the OFF position in the clockwise direction NOTICE Be sure the fuel SWITCH is in the OFF position and the start switch is in the STOP position when stopping transporting and or storing the generator FOR DC OPERATION An overloaded DC circuit excessive current draw by the battery or a wiring problem will automatically trip turn off the DC breaker switch If this happens wait a few minutes before pressing the breaker switch to the ON position to resume operation If the breaker switch continues to go OFF discontinue charg ing and contact your authorized dealer HY3000sei User
17. omer support center for technical advice a warranty claim or general information Do not return your generator to the place of purchase for repair MIDLAND IN TERNATIONAL INC SHOULD BE CONTACTED TO PROVIDE A CASE NUMBER BEFORE WARRANTY WORK CAN BEGIN To obtain warranty service Contact our customer support centre TOLL FREE 1 877 528 3772 E MAIL SUPPORT HYUNDAIPOWER CA WEBSITE WWW HYUNDAIPOWER CA 30 HY3000sei User Manual GLOSSARY AC SOCKET The receptacle for the device plug used for AC application AC CIRCUIT PROTECTOR It protects AC circuits from being damaged due to overload or short circuit by stopping the flow of electricity between the genera tor and device AIR FILTER It removes dust from engine intake air CARBURETOR A device used to properly mix fuel and air in the correct propor tions and deliver the mixture into the engine s combustion chamber CHOKE ROCKER It is used to provide proper starting mixture when the engine is cold The choke lever must be pulled out to ON position when starting a cold engine DC BREAKER SWITCH It protects DC circuits from being damaged due to over load or short circuit by stopping the flow of electricity between the generator and device DC SOCKET The receptacle used for charging a 12 V battery DIPSTICK It seals off engine oil fill hole and is used for indicating the engine oil level DRAIN PLUG A plug that can be removed to allow the fluid contents of
18. or cannot start because the fuel cannot reach the carburetor Procedure for using the primer bulb 1 Set the choke rocker in the OPEN position 2 Push the primer bulb 7 to 10 times 3 Move the choke rocker to the CLOSE position and start the engine USING THE GENERATOR SET Connections for standby power to a building s electrical system must be done by a qualified electrician and must comply with all applicable laws and electrical codes Improper connections may cause serious injuries to electrical worker during power outages Additionally the generator may explode or cause fires when the utility power is restored WARNING e To prevent electrical shock from faulty appliances the generator should be grounded e Limit operation requiring maximum power to 30 minutes e Do not exceed the current limit specified for any one receptacle e Do not connect the generator to a household circuit e Do not modify or use the generator for other purposes than it is intended for e Be sure to use properly isolated cable when an extension cable is required e Limit length of extension cables to 60 m for cables of 1 5 mm wire thickness and 100 m for cables of 2 5 mm wire thickness e Keep the generator away from other electric cables or wires such as a distribution network e The DC receptacle can be used while the AC power is in use If you use both at the same time be sure not to exceed the total power for AC and DC e Before connecting a
19. ording to user manual instruc tions on page 18 HY3000sei User Manual 25 HYUNDAI SPECIFICATIONS WATTS AMPS MOTOR START OUTLETS FUEL CAPACITY MAX AC OUTPUT FUEL TYPE RUNNING TIME NOISE LEVEL FRAME DIMENSIONS WEIGHT 26 2800W Peak Power 2600W Running Power Output Current 21 6A Max Circuit 23 3A 5 3HP 5500RPM 4 Stroke 150CC Hyundai Motor Manual Recoil and Electric Start Two 120V 21 6A AC One 12V 8 3A DC One USB 4 5L 2800W Unleaded Gasoline Minimum Octane of 87 3 hours 70 65dB 7m 33 mm Polypropylene 575x330x525 mm 35 kg HY3000sei User Manual RECOMMENDED OIL USAGE HYUNDAI OIL GRADE TEMPERATURE SEASON 5W40 0 amp below Winter 10W40 20 to 5 Spring Fall 15W40 20 Summer 10W30 25 to 15 All season SPARK PLUG COMPATIBILITY BRAND HY3000SEI NGK CR7HS DENSO U20FPR CHAMPION RZ10YC BOSCH U24BC HY3000sei User Manual 27 HYUNDAI WARRANTY WARRANTY TERMS AND CONDITIONS Canadian distribution of Hyundai branded portable generators are distributed by Midland Power Inc 376 Magnetic Drive Toronto ON Canada M3J 2C4 This product is warranted to be free of defects in material and workmanship for two years from date of purchase This warranty guarantees that any defective parts will be repaired or replaced at no cost including diagnosis and replace ment parts Limited Warranty periods Recreational re
20. sehold power supply should be done by a professional electrical technician Improper con nections may lead to a fire hazard or damages to the generator set MAINTENANCE SAFETY After any maintenance is performed wash your body immediately us ing soap and clean water Repeated exposure to lubricant may cause skin irritation Do not clean the filter sponge with flammable fluids such as gasoline or explosion may occur Turn off the generator set before performing any maintenance Other wise it can cause severe personal injury or death Allow the generator set to cool down before performing any mainte nance Always wear safety glasses when cleaning the generator with air Do not clean the generator set with a pressure washer because it may cause damage to the generator set Before working with batteries ventilate the area wear safety glasses do not smoke and always disconnect the negative cable first and reconnect it last Use rubber gloves when coming into contact with engine oil Always stop the generator set before removing the oil filler cap Only qualified maintenance personnel with knowledge of fuels electricity and machinery hazards should perform maintenance procedures HY3000sei User Manual HYUNDAI OTHER SAFETY HAZARDS To avoid breathing in poisonous carbon monoxide from the exhaust gases adequate ventilation should be provided if the generator set is running in a partially enclosed space If the genera
21. sidential use 2 years limited 1st year parts and labour 2nd year parts only Commercial use 6 months limited parts and labour This limited warranty begins at the initial time of retail purchase and covers manufacturer s defects caused by a defect in components or workmanship during the two year 2 year period The warranty coverage is continual from the initial date of purchase and does not restart at anytime under any circumstanc es This limited warranty is valid for residential or recreational applications only and only when the generator receives all necessary preventative maintenance as described in the Hyundai Generators Operation Manual The repair or replace ment of a generator will take place within a reasonable period of time during normal business hours All repair and replacement parts shall be warranted for 90 days after the initial date of installation or purchase Limitation of Remedies and Disclaimers Midland International Inc disclaims any responsibility for loss of time or use of the generator in a recreational vehicle or any vehicle in which the generator is installed transportation commercial loss or any other incidental or consequen tial damage Any implied warranties are limited to the duration of this written warranty THE FOREGOING LIMITED WARRANTY IS EXCLUSIVE OF AND IN LIEU OF ALL OTHER WARRANTIES OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE AND OF ANY OTHER WARRANTY WHETHER EXPRESS OR IM
22. t down the engine If the oil alert system shuts down the engine the oil alert indicator will come on when you operate the starter and the engine will not run If this occurs add engine oil FUEL LEVEL CHECK 1 Check fuel level display located on top of generator gas tank 2 Refill the fuel tank if the level is low Refuel carefully to avoid spilling fuel Do no fill above the upper limit mark Refer to Fig CAUTION e Gasoline is highly flammable and explosive Keep the engine away from heat spark the open flame e Refuel in a well ventilated area with the engine stopped e Only handle fuel outdoors e Wipe up spills immediately e Avoid getting dirt dust or water in the fuel tank e Never use an oil gasoline mixture or dirty gasoline e Do not use fuel containing alcohol Fuel system damage or en gine performance problems will result from the use of fuels that contain alcohol e Avoid repeated or prolonged contact with skin or breathing of fuel vapor Cover of fuel cap 7 Fuel cap irn HY3000sei User Manual 9 HYUNDAI CHECK THE AIR FILTER 10 8 D WARNING Never run the engine without the air filter Rapid engine wear will result from contaminants such as dust and dirt being drawn through the carburetor into the engine Remove air filter cover and sponge Inspect filter sponge for dirt and debris Clean filter sponge by soaking in gasoline ring out before reinstalling Replace air filter e
23. the engine to be drained off ECON SWITCH This system can be described as a load dependent speed control type governor that offers excellent fuel economy by automatically adjusting engine speed to the optimum level given the usage load This not only reduces fuel consumption and operating noise in the normal usage range but it also keeps exhaust emissions to levels low enough to clear some of the strictest CARB and EPA emission standards FUEL SWITCH It controls flow of fuel from fuel tank to carburetor GROUND TERMINAL It connects generator to ground wire for grounding protec tion HY3000sei User Manual 31 HYUNDAI OIL INDICATOR LIGHT Before the oil level falls below a safe limit the Oil Indicator light red will go ON and the Oil Alert system will automatically stop the engine OUTPUT INDICATOR LIGHT The output indicator light green is illuminated when the generator is operating normally It indicates that the generator is producing power at the receptacles OVERLOAD INDICATOR LIGHT If the generator is overloaded or if there is a short circuit in a connected device the overload indicator light red will go ON It will stay ON and after about four seconds the device will shut off and the output indicator light green will go OFF RECOIL STARTER A pull cord is attached to the engine and you pull the T handle attached to the starter cord assembly to spin the fly wheel and start the engine SPARK PLUG A devi
24. tial Date of Purchase and continues after ownership has transfered New owners should be made aware of expired or remaining coverage HY3000sei User Manual 33 HYUNDAI 34 HY3000sei User Manual HYUNDAI REGISTRATION INSTRUCTIONS Ownership must be registered with Hyundai Power Equipment in order to ensure continued warranty and service support Please fill out the registration card below and mail it along with a copy of your receipt and the original UPC barcode from your product packaging The store date of purchase and product purchase should be clearly visible on the receipt copy YOU MAY ALSO REGISTER ONLINE BY VISITING OUR WEBSITE WWW HYUNDAIPOWER CA If you wish you can confirm your registration by calling customer service at or by email at support hyundaipower ca Please allow one week for mail delivery and processing Please mail all items to Midland Power Inc Product Registration 376 Magnetic Drive Toronto ON Canada M3J 2C4 Lie Berd ent Warranty Registration Card Existing Owner Information First Name Last Name Company Street Name and Number City Postal Zip Code Province State Phone Number Other Contact Number Fax Number Email Product Information Model Name Serial Number can be found on the Generator or on the exterior of the packaging inital Date of Purchase Warranty Expiration Date of Transfer Add 2 yours to initial date of purchase L 4
25. tor set is stored outdoors check all the electrical compo nents on the control panel before each use Moisture can damage the generator and can lead to an electric shock IDENTIFICATION OF COMPONENTS Top Maintenance Cover Fuel Cap Cover Control Panel Starter Grip Rear Cover Primer Bulb Fuel Switch Maintenance cover HY3000sei User Manual HYUNDAI PRE OPERATION INSPECTION WARNING e Ensure that the generator is on a level surface and the engine is turned off before inspection ENGINE OIL INSPECTION Use high detergent premium quality 4 stroke engine oil Select the appropriate viscosity for the average temperature in your area 1 Loosen the cover screws and remove the maintenance cover refer to fig 2 Remove the oil filler cap and wipe the dipstick clean refer to fig Check the oil level by inserting the dipstick into the filler neck without rotating it 3 If the level is low fill to the upper limit of the oil filler neck with the recommended oil 4 Reinstall the maintenance cover and tighten the cover screws Maintenance cover Cover Screw A Upper limit Dipstick Oil Filler Cap Lower limit 8 HY3000sei User Manual HYUNDAI NOTICE The oil alert system is designed to prevent engine damage caused by an insufficient amount of oil in the crankcase Before the oil level in the crankcase falls below a safe limit the oil alert system will automatically shu
26. up 5W40 for temperatures below 0 C 4 Fouled spark plug replace with equal or greater quality plug 24 HY3000sei User Manual HYUNDAI Engine idle fluctuates Carburetor in need of tuning For details on how to adjust correctly please contact your local service centre or contact Midland Intl Inc at 1 877 528 3772 Missing ground reference on return side of differential analog output external Air filter element obstructed by debris Clean according to user manual instruc tions on page 18 Engine stops Engine idles down and shuts off The on off switch is in the Off position The engine is out of gasoline Add regular unleaded gasoline Air filter element obstructed by debris Clean according to user manual instruc tions on page 18 Adjust choke lever according to user manual instructions on page 12 Incorrect oil being used or insufficient oil level Always ensure high oil levels and use oil according to oil usage chart in user manual on page 27 Fouled spark plug replace with equal or greater quality plug Refer to page 27 in your user s manual for a complete list of spark plug compatibility codes Thick smoke released from exhaust Exhaust fumes thick and dark Adjust choke lever according to user manual instructions on page 12 Incorrect oil being used Use oil accord ing to oil usage chart in user manual on page 27 Air filter element obstructed by debris Clean acc
27. ure the fuel cap is closed tight Loosen the cover screws and remove the maintenance cover Place a container next to the engine to catch the used oil Remove the oil filler cap dipstick and drain the oil into the con ainer by tilting the generator Remove the screw top maintenance cover and the spark plug Fill the spark plug orifice with 2cc s about a tablespoon of fresh oil Pull the start motor 3 4 times to distribute the oil Reinstall the spark plug top maintenance cover and screw securely Pull the starter grip slowly until you feel resistance then return he starter grip gently This closes the valves so moisture cannot enter TROUBLESHOOTING If the generator still does not start have an authorized Hyundai repair technician diagnose and repair the problem Attempting service or repair without the proper training tools and equipment may cause injury to you and or others It can also damage the generator or lead to hazardous conditions For more information please refer to the troubleshoot guide below WARNING 22 Many troubleshooting procedures present hazards which can result in severe personal injury or death Only trained and ex perienced service personnel with knowledge of fuels electric ity and machinery hazards should perform service procedures Review Safety Precautions A hot generator can cause sever burns Always allow the genera tor set to cool before performing any maintenance HY3000sei User M
28. very 24 months or when necessary Air Filter Sponge Maintenance Cover Air Filter Cover Screws HY3000sei User Manual HYUNDAI OPERATION STARTING THE GENERATOR SET NOTICE e A hot engine will not start if there is too much gasoline in the cylinder If this happens wait for 5 to 10 minutes for the engine to cool down before starting e The engine will stop automatically when it is out of gasoline e When the output indicator light green does not light and the overload indicator light red lights instead set the engine switch to STOP stop the engine at once and then start the engine again RECOIL START 1 Rotate the fuel switch to the ON position according to the arrow direction 2 Flip the engine switch to the ON position 3 Pull the starting grip lightly until resistance is felt then pull briskly to start the engine Refer to Fig WARNING e Do not allow the starter grip to snap back Return it slowly by hand e Grasp the carrying handle firmly to prevent the generator from falling over when pulling the starting grip HY3000sei User Manual 11 HYUNDAI NOTICE e If the engine stops and cannot be restarted check oil level be fore troubleshooting other possibilities e Ensure ECON switch is off before turning on any connected de vices PRIMER BULB The primer bulb is used for bringing small amounts of gasoline to the throat opening of the carburetor The problem is that sometimes generat

Download Pdf Manuals