Home
PPA Datalogger Data Logging Software Software User Manual
Contents
1. Results that have been loaded can be re exported to CSV or Excel 68 PPA Datalogger Software User Manual 12 2 Importing CSV Files into Excel CSV Files exported from any mode in PPA Datalogger can be loaded into Excel as data creating a spreadsheet from the CSV To load the data into Excel open Excel and select the first cell to enter the data into Home Insert Page Layout Formulas qe jeb E SIE d ET Connections E Ei Er 9 4A Properties From From From Other Existing Refresh Access Web Text Sources Connections All Edit Links mE Connections m ss Get External Data From Text Import data from a text file L w Press Fl for more help After navigating to and selecting the file to be loaded into Excel press the Import button 69 PPA Datalogger Software User Manual x Import Text File Organize New folder Libraries Documents a Music i Pictures Subversion BE Videos Mame Lj aircraft direct to csv txt Export To CSV txt L measure log plus date txt Lj Scheduled Test 02 10 2015 12h 12m 0 Lj Scheduled Test 02 10 2015 12h 30m 0 Date modified 06 10 2015 09 05 05 10 2015 10 18 05 10 2015 15 28 06 10 2015 08 48 06 10 2015 11 17 02 10 2015 12 15 02 10 2015 13 30 Type Text Document Text Document Text Document Text Document Text Document Text Document Text Document 864 KB 265
2. 61 11 3 Selecting Variables r 62 IL 4 Wind EQUATIONS u u u 03 11 5 Selecting Equations as Multilog Parameters 65 12 Using PPA Datalogger CSV Files 67 12 1 Loading results from a CSV File 67 12 2 Importing CSV Files into Excel 69 PPA Datalogger Software User Manual Appendices Appendix A Contact Details PPA Datalogger Software User Manual 1 Introduction 1 1 Introduction to PPA Datalogger PPA Datalogger is a self contained executable software program written in C using the Microsoft win32 graphics set PPA Datalogger has the ability to connect to the PPA series of instruments via RS232 USB and LAN The software includes all measurement modes to reflect instrument operation PPA Datalogger supports the ability to export text files in CSV format as well as export directly to Microsoft Excel This guide was written using a PPA5530 with Firmware version V2 125 1 2 Minimum Requirements The minimum requirements to run the PPA Datalogger Software are as follows B Windows XP Service Pack 3 or later B At least 1Ghz Processor B Minimum of 1GB RAM B 10MB of Hard Drive space PPA Datalogger Software User Manual 2 Getting Started 2 1 Download As with all N4L Software it is available for free download from our website See www newtons4th com su
3. Test1 Settings PPA5530 cfg 30 09 2015 10 30 CFG File ow Libraries Documents Music Pictures Subversion B Videos W Computer L Windows OS C f DVD Drive D 15 0 4420 File name Test 1 Settings PPA5530 cfg gt Config Files cfg F e The imported configuration will be saved to the next empty space in your saved configurations and instantly loaded into the Configuration Panel Confiqure Display Measure Harmonics Scope Capture SFT LIB Connection Ee ppaa SETTINGS READ PPA SE Saved Config Load Load Test 1 Settings PPA5530 Open CSV File Save Load Test 1 Settings PPA5530 Settings Export Load empty Add Edit Equations EPOR Eo ls nad emnt To ensure the instrument is setup with the settings that have just been loaded press the SET UP PPA button just above the Configuration Panel 17 PPA Datalogger Software User Manual 5 The Display Menu 5 1 Using the Display Menu The Display menu is used to save the displayed screen as a picture Configure Disp Measure Harmonics CONTROL Save to Bitmap Copy to Clipboard L Export to Word Acou cCOUPLNG RANGE The following screens can be saved B Measure Mode s Real Time display Frequency PH1 Watts PH1 VA PH1 RMS Voltage PH1 Fund Voltage PH1 Peak Voltage PH1 B Measure Mode s Graph z nn c 7 30000 n 8 00
4. Your selection will now be saved as requested PPA1 Multi Log Selection STORE RECORD SELECTION Load PHI PH2 PH3 SUM NEU Save k Save Current PPA1 Save Current Save Current PPA3 Save Current PPA4 Save 3p sum VRMS and VTHD Save empty 26 PPA Datalogger Software User Manual 6 7 Loading a Multilog Selection To load a saved configuration click the STORE RECORD SELECTION menu in the top left corner of the Multilog Window and highlight Load and click on any of the 13 slots therein PPA1 Multi Log Selection STORE RECORD SELECTION Load 1 Current PPAL Save d Current PP A2 Current PPAS Current PP A4 Load 3p sum VRMS and VTHD Load empty Load empty Load empty Load empty Load empty Fund Load empty Load empty Load empty Fundamental Voltage The first 4 slots are for the last used Multilog Parameter setup used by that PPA through the software The remaining 9 slots are for user saved setups Once one of the slots has been pressed the Multilog Window is populated with the Multilog Parameters from that saved setup and the Selected Items list is filled PHI PH PHS SUM Selected Items otage Phase Ange Function Channel votesesuee J O O TP Curent Surge Fl amp Frequency PHI hanical Speed Hz E Watts anical Speed rpm F RMS Voltage PH1 Torque E RMS Volt
5. ED e n File Edit Format View Help Time Frequency PH1 PPA1 Watts PHI PPAT RMS Voltage PH1 PPAT RMS Voltage PH2 PPAT RMS Voltage PH3 PPAT RMS Voltage SUM PPAI Voltage THD PH1 PPA1 Voltac 4 10 15 19 042 5 00000E1 1 98220E 8 2 58730E 2 4 47900E 2 4 801 50E 2 3 95600E 2 4 68830E2 2 02970E3 4 32960E2 0 00000E0 10 15 20 042 5 00000E1 4 381 90E 8 2 59280E 2 4 481 00E 2 4 8001 OE 2 3 95800E 2 4 12840E2 6 19050E3 7 38640E2 0 00000E0 10 15 21 042 5 00000E1 8 25610E 8 2 59940E 2 4 49050E 2 4 79620E 2 3 96200E 2 3 15890E2 5 08600E2 7 53350E2 0 00000E0 10 15 22 049 5 00000E1 4 21770E 7 2 62290E 2 4 49010E 2 4 78450E 2 3 96590E 2 5 15520E2 8 63270E2 1 72110E3 0 00000E0 10 15 23 041 5 00000E1 3 51340E 7 2 61620E 2 4 49050E 2 4 78700E 2 3 96460E 2 4 36490E2 7 97810E2 1 30450E3 0 00000E0 10 15 24 042 5 00000E1 3 13330E 7 2 61520E 2 4 4801 0E 2 4 78660E 2 3 96060E 2 3 24450E2 2 65400E2 7 09890E2 0 00000E0 10 15 25 042 5 00000E1 2 64330E 7 2 61210E 2 4 51160E 2 4 78760E 2 3 97040E 2 2 99060E2 9 59950E2 2 16080E3 0 00000E0 10 15 26 049 5 00000E1 2 35220E 7 2 61 400E 2 4 48730E 2 4 79650E 2 3 96600E 2 2 47250E2 6 82410E2 1 97710E3 0 00000E0 10 15 27 041 5 00000E1 2 641 10E 7 2 61520E 2 4 48760E 2 4 79790E 2 3 96690E 2 2 29110E2 5 34510E2 1 41300E3 0 00000E0 10 15 28 042 5 00000E1 3 34160E 7 2 61150E 2 4 48760E 2 4 79490E 2 3 96470E 2 1 72310E2 9 63960E2 1 95530E3 0 00000E0 10 15 29 043 5 00000E1 1 44240E 7 2 61750E 2 4 49360E 2 4 79580E 2 3 96900E 2 2 11300E2 4 97
6. Once the Correct PPA is selected click the appropriate tick box this will populate the corresponding measurement parameter and phase to the selected item list p Selected Items gt PHI PH2 PH3 SUM NEU ee Function Channel Frequency PH1 Watts SUM VA PH1 VA PH2 VA PH3 You can then rearrange the order these parameters will be displayed using the UP and DOWN button and remove them all at once using the CLEAR button or delete individually by selecting the parameter to be deleted in the Selected Items list and pressing REMOVE Additionally if you want to add Equations press the Maths button Finally upon completion press the OK button in the bottom right corner 25 PPA Datalogger Software User Manual 6 6 Saving a Multilog Selection Once you have selected your Multilog Parameters you are able to save your selections by pressing the STORE RECORD SELECTION menu in the top left corner of the Multilog Window and highlight Save and click on one of the 9 unreserved save slots PS V Log Seo RR PHH PH Save Current PPAT1 Save Current PP AZ Save Current PPA3 Save Current PPA4 Save empty Save empty Save empty Save empty Save empty Save empty Save empty Save empty Save empty PH3 SUM NEU ESSET m m OK Please enter the new name for the configuration 3p sum VRMS and
7. Harmonics Scope Capture CONTROL PPAL PPA PRA 4 CONTROL PPAL Configuration Acqui Arw Far gms TR D ARCE This switches PPA Datalogger over to Harmonics mode Harmonics View Harmonics Control Export to Excel Data Settings TABLE TABLE pk GRAPH START EXPORT Range 300mV 30mA 300mV 30mA 30mA Coupling ac dc Bandwidth Wide AEG Harmonics In Harmonics Mode the data recorded can be set to log direct to CSV To set Harmonics up to do this tick Log To CSV press Select File and set the CSV file location remove the and name the file then press Save G Select file for CSV logging eme _ x Sed k Computer Windows7 OS C PPA Datalogger Log Files Search PPA E Organize v New folder J pending releases a Name Date modified Type dJ Utilities Export To CSV txt 05 10 2015 10 18 k Product Manuals t D l Scheduled Test 02 10 2015 12h 12m 0 02 10 2015 12 15 Text Documen Text D Gg Librari l Scheduled Test 02 10 2015 12h 30m 0 02 10 2015 13 30 ibraries Documents Music i Pictures Subversion B Videos Computer L Windows OS C f DVD Drive D 15 0 442 File name Ne Lii CN A s Save as type Cancel Hide Folders 42 PPA Datalogger Software User Manual The harmonics graph can be edited
8. PPA Datalogger Data Logging Software a PPALog Software User Manual constructed using Software version v3 28 PPA Datalogger Software User Manual ABOUT THIS MANUAL PPA Datalogger is a self contained executable software program for use with the N4L PPA500 PPA1500 PPA2500 PPA2600 PPA4500 and PPA5500 power analyzers Accordingly this manual first describes the general features and specification of the software as a whole and then describes the individual functions in detail Each function is described in turn in its own chapter with details of the principles on which it is based how to use it the options available display options etc Revision This manual is copyright 2004 2015 Newtons4th Ltd and all rights are reserved No part may be copied or reproduced in any form without prior written consent PPA Datalogger Software User Manual Table of Contents L Introductio 6 1 1 Introduction to PPA Datalogger 6 1 2 Minimum Requirements 6 2 Getting Started soia cia ERR T 7 2 0 EE VIE Pena 7 22 MNS MaA ac 7 2 3 Optional installation Equations 7 2 4 SORWareSSsUImdsssseeesteuckinvbiu dato tas ast vi RES eoeeae 8 3 u a 9 3S Ll Prepanng Ine PPA eas veu tone p ia 9 3 2 Connec
9. sl E sl m sl sl al e Fi I E A m E T A s al Add ADI Qutput Remave Voltage Harmonic Current Harmonic 55 ph ph RMS Voltage ph ph Fundamental Voltage 3 E31 ES ES ES EERESEEERRR0E000 F000 FO HBSS ES ESI ESI ESI ESIESIE ESTE ESTE ESI ESI ESI ESI EEESEESE F000 FO HOSE EE ESI ESI ESI EIE ESTE ESTE ESI ESI ESI ESI EEEREESE omaan FO F3 Ex ES ESSE ESEESEESEES EISE ES ES ES ES ESEERIESE 000 GEG GEG GEG GEG The parameters are colour coded with the following colours B White General purpose Multilog Parameters B Pink THD parameters Selecting these will put the PPA in Harmonics mode while measuring using either Difference or Series computation Current THD ir I PJ B Blue Deviation parameters these can only be measured with other blue parameters B Green impedance parameters these can only be measured with green or white parameters B Orange Integrated Parameters Puts the PPA in Power Integrator mode unless paired with pink parameters 24 PPA Datalogger Software User Manual 6 5 Selecting Parameters The first thing to do when in the Multilog Window is to ensure the correct PPA is selected to have its associated measurement parameters configured To select the correct PPA click on the arrows in the top left corner PPA Multi Log Selection iin 4 STORE RECORD SELECTION
10. 38544 uv 447 83 uV 48053 uv 470527 uV 454 5 uv PH2 A 41433 uA 4n 566 uA 41 987 uA 43 370 uA 44442 uA 35 383 uA 435385 uA 44 335 uA 42 743 uA 46 750 uA 41 305 uA 38850 uA 38545 uA 1000096 7149 995 4372 595 5753 536 93572 396 11869 156 5523595 1112808 5187195 4803 395 S453 095 51759 3131356 PH3 V 404 65 uv 488 54 ul S211 455277 uv 41007 uV 14028 mV 22104 mV 53373 UW 585 44 uv 18682 mV 40446 uv AOI ZI uv 406 97 uv 48809 uv 12499 mV phase s dropdown boxes and selecting None on the left of the graph PPA1 Harmonics Phases Voltage H2 H40 100 P 300mV 30mA 300mV 30mA 300mV 30mA 30mA 44 in iri Ci in PPA Datalogger Software User Manual Hovering the mouse over any area in the graph shows a tooltip that displays the data for all phases for that harmonic Upon completion of a test selecting the log to CSV parameter will populate a txt file with each line of Harmonics data read by the software from the instrument 7 harmonics direct_to_csvitet Notepad Y l l l l l l l File Edit Format View Help Time Harmonic Frequency PH1 V PH1 V PH1 A PH1 A PH2 V PH2 V PH2 A PH3 V PH3 V PH3 A PH3 A NEU A NEU A 13 43 02 419 1 1000 00000 0 000306 1 00 0 0 000007 1 00 0 0 0001 25 100 0 0 000009 100 0 0 000068 100 0 0 000008 100 0 0 000005 100 0 13 43 02 419 2 2000 00000 0 000077 25 3 0 000006 81 7 0 0
11. 51032 uW TI 25 uW EB 447 uW TEZLI uV 87158 ul 52975 uy 58 557 uV 30527 uW n PHZ A 359007 u 52599 u 40874 uA 45203 uA 13783 uA 42903 uA 10054 uA 11865 uA 9 5069 uA 55518 u 3 uA 7 8335 uA 3 8405 uA 54125 uA 184538 uA PH3 V 51096 uW 81051 uW 32 840 uV 104 85 uV 49 997 uv ELSES uW 51584 uV 155653 uV 65215 uV 23255 uW 57 093 uV 4 191 uV 13510 uW 11209 uV 28732 uW PH3 A 3 9587 uA 81444 uA 11 267 uA 3 5083 uA 15043 uA 134813 uA 109279 uA 15377 uA 53102 uA 322281 uA 120334 uA 4 1075 uA 10159 uA been setup pressing the START The Table view shows the latest set of data read by PPA Datalogger Table pk shows the highest values read during the test a jH Ln Graph shows each harmonic as 3 bars 4 for current representing each phase Each bar can be hidden using the PHI V 58573 UW 457 57 uV 513 54 uV 45188 uW 455 168 uV 427 30 uv 39422 uV 473 91 uV 43251 uV 445 01 uV 54575 uV 10275 mV 35313 uV 485 20 29436 mV PHI V 56 10045 357 456 715 396 453 456 3124096 559 796 454 1 615 7 2304 855 PHI A 37 602 uA 58 590 uA 38384 uA 39 665 uA 33454 uA 39483 uA 38155 uA 37 631 uA 33 863 uA 35 381 uA 37 423 uA 43336 uA 39 567 uA 42152 uA 44 299 uA PHIL A 100096 11435056 10545096 T405 895 655 2 396 12535 095 3245 736 PH V 56601 uv 48305 uv ag 7 uv 406 76 uV 455 57 uM 438 38 uv 436 31 uv 447 87 uv B58 32 uV 48305 uV
12. Default button Test Save as Default 11 PPA Datalogger Software User Manual If this is the first time you ve used PPA Datalogger you will need to enter an Unlock Code if you haven t received an Unlock Code contact your local Newtons4th Distributer or our Support team Test Test Cancel Once you press Connect or Unlock the software will then connect to and download the Configuration settings for each instrument it is able to connect to 12 PPA Datalogger Software User Manual 4 Configuration Panel 4 1 Using the Configuration Panel All of the connected instrument s settings are stored in the configuration panel and can be edited and sent back to the instrument 8 PPAG CONTROL PRAL anfiguration Acquisition Control ACQU COUPLING RANGE Wiring a phase 3wattmeter Frequency Reference Voltage Speed Medium Phase Angle Reference Voltage APP w Smoothing Normai Frequency Filter lom Smoothing Response Auto reset Low Frequency om First select which PPA s settings to change by selecting one of the PPAs using the PPA Control buttons Once an appropriate PPA is selected the next step is to READ PPA this enables the software to download that PPA s settings to ensure the software is configured with any changes that have been made to the PPA s settings on the instrument s front panel hen choose which settings menu to look at and edit the individual instruments s
13. PPA 2 PPA 3 PPA 4 Interface Interface USB g Interface LAN E Interface COM Port COM Port COMID IP Address 197 1682 0 55 a IP Address 192 158 0 147 aud Rate 19200 Baud Rate 19200 You can chose to connect to up to 4 different PPA Instruments by selecting 3 Phase 6 Phase 9 Phase or 12 Phase Then you set each PPA s communication details by selecting the communication method either Serial USB or LAN If you selected LAN you ll need to enter the same IP as you set your unit to If you selected USB or Serial you ll need to select the COM port that windows assigned to your cable Additionally if you select Serial you ll need to set your cable s Baud Rate 10 PPA Datalogger Software User Manual To check the connection settings are correct press the Test button to attempt a connection This will then bring up a message telling you if the connection was successful If you failed to connect it will bring up a message telling you the connection failed Test Connection If the connection was successful the message will tell you the details of the instrument you are connected to such as its model serial number and firmware level Test Connection AE The connection was successful b p NEWT ONS47TH PP45530 165 00768 2 125 OK If you want PPA Datalogger to remember your current connection settings and reload every time you open the connection window you can do so by pressing the Save as
14. as a Sage of Ph2 Equation WattsPH1PPA1 WattsPH2PPA1 100 Cem Lond Equation Once the Equation is written and named press the Save button Sawe 64 PPA Datalogger Software User Manual 11 5 Selecting Equations as Multilog Parameters To add an Equation to the Multilog Parameter Selection in the Multilog Window press the Maths button REMOVE Add ADI Input Then select the Equation to add from the list and press the Load button Load Equation Equation Watts Phi asa WattsPHIPPAL WattsPH2PPA1 100 And the equation is now in the Selected Items list Selected Items Function Channel Watts Phi as a Sage of Ph2 N A Make sure to add the Multilog parameters used in the equation or it will not work Selected Items Function Channel Watts as a age of PhZ ALA Watts PHL Watts PH2 65 PPA Datalogger Software User Manual The Equation will act just like a normal Multilog Parameter and will be available for viewing in Real Time View Graph View and Log View equations also export to both Excel and CSV PPA1 RESULTS Watts Ph1 as a age of Ph2 Watts PH1 Watts PH2 66 PPA Datalogger Software User Manual 12 Using PPA Datalogger CSV Files 12 1 Loading results from a CSV File To load previous Measurement Mode results from a CSV file into PPA Datalogger click on Configure followed by Open CSV File Connection Saved Config Open CSV Fil
15. 01020269E 005 4 47056722E 004 1 70702697E 005 1 8884451 1E 004 2 76752398E 005 42 8 40000000E 002 1 63519941E 003 1 41476921E 005 1 81116536E 003 8 851 72049E 005 6 0742721 0E 004 6 61795493E 005 43 8 60000000E 002 2 4252641 0E 004 1 72921573E 005 1 14766322E 003 1 06402877E 005 6 27454370E 004 6 6261 1565E 005 44 8 80000000E 002 1 21204881E 004 2 1612941 1E 005 2 26091594E 004 1 87624828E 005 2 7855671 9E 004 3 86914471E 005 45 9 00000000E 002 4 43683239E 005 1 13673013E 005 4 70304396E 004 2 74558843E 005 1 37460651E 004 1 36473100E 005 46 9 20000000E 002 2 03101197E 004 9 27498331E 006 1 8675741 7E 004 2 78837688E 005 2 27052486E 004 4 50157677E 006 47 9 40000000E 002 8 10464844E 005 3 24980938E 005 2 22556060E 004 3 002092 1 3E 005 3 14699137E 005 2 49363657E 005 48 9 60000000E 002 1 21092657E 004 1 16994925E 005 5 98223996E 005 2 2935681 0E 005 1 04651670E 004 3 68280453E 005 49 9 80000000E 002 2 12004874E 004 2 29692669E 005 3 81899998E 004 1 69253326E 005 1 07144471E 004 2 79784435E 005 50 1 00000000E 003 2 8280541 3E 004 2 17578781E 005 2 93105375E 004 2 06102850E 005 5 93861332E 005 2 15253385E 005 51 1 02000000E 003 2 18329486E 004 7 82008283E 006 2 20433576E 004 2 00985232E 005 1 66819198E 004 2 35823973E 005 52 1 04000000E 003 6 99005323E 005 1 88824488E 005 3 96086834E 005 2 40572845E 005 8 72571254E 005 1 70209387E 005 53 1 06000000E 003 2 44423281E 004 1 22819329E 005 1 99879520E 004 3 18282982E 005 1 624461 73E 004 3 33150383E 005 54 1 0
16. 18 9 00000000E 001 1 64685305E 004 1 98631024E 005 9 95136797E 005 9 56909207E 006 1 46753853E 004 1 08389504E 005 19 9 50000000E 001 1 61821721E 004 1 92157459E 005 7 19561940E 005 1 08409877E 005 1 43017620E 004 6 18421473E 006 20 1 21 1 22 1 23 1 24 1 25 1 26 1 27 1 28 1 29 1 30 1 31 1 32 1 33 1 34 1 39 1 36 1 37 1 38 1 39 1 00000000E 002 4 34650574E 005 4 28262865E 006 1 06398831E 004 1 93970627E 005 1 8175691 4E 004 3 52927236E 006 05000000E 002 2 93759804E 005 2 66140705E 006 7 75058288E 005 1 03523489E 005 2 29505240E 005 5 83050860E 006 10000000E 002 4 14852402E 005 8 07826291E 006 2 25482509E 004 1 38156029E 005 1 23288948E 004 9 18353908E 006 15000000E 002 1 17056188E 004 1 68703446E 006 1 12161855E 004 1 64125522E 005 8 6916261 4E 005 7 12113979E 006 20000000E 002 7 59589020E 005 4 30064392E 006 6 76563941E 005 1 49336847E 005 1 25497754E 005 1 86614488E 006 25000000E 002 9 59731406E 005 1 32467103E 005 7 46345613E 005 1 18958706E 005 1 16328942E 004 4 40966687E 006 30000000E 002 7 142801 77E 005 1 38669420E 005 1 06333755E 004 6 51778828E 006 3 86532047E 005 9 69409302E 006 35000000E 002 4 66757920E 005 6 48745481 E 006 4 72319662E 005 7 60357216E 006 2 03921925E 004 1 52031716E 005 40000000E 002 1 11734611E 004 9 28535883E 006 8 16023676E 005 1 15141011E 005 9 40186437E 005 4 59857256E 006 45000000E 002 4 61 775926E 005 7 17817602E 006 6 14689197E 005 1 25617225E 005 4 95878630E 005 1 27805251E 005 50000000E
17. 24 10 2013 09 50 i Pictures J Dell Image Expert Images 30 08 2013 14 24 Subversion i DEP 06 08 2013 10 06 Videos k IEC Screenshots 02 05 2013 08 36 k Icr repeating 24 04 2013 17 05 Computer NVIDIA Corporation 16 04 2013 13 24 Windows OS C J Piezo guide 12 04 2013 1412 r DVD Drive Dz 15 0 4420 M mum mida na ma ans 212 53 lt M L PXAIL ArLcr Filename PPADataloggerScreenshot brmp Save as type Hide Folders Once a location has been selected press the Save button to Save the screenshot 19 PPA Datalogger Software User Manual 5 3 Copy to Clipboard Copy to clipboard saves the image in your windows clipboard The screenshot can then be pasted anywhere that you d normally use an image such as an Email a Picture Editor eg MS Paint Microsoft Word Microsoft Excel etc 5 4 Export to Word Export to word creates a new blank Word Document with the image placed at the top of the first page 11 X lal Em fm Se s 21 aasbcco AaBbi at Painter B Z abe x A A amp x is W No Spaci Heading Fi F F Font Meubral 20 PPA Datalogger Software User Manual 6 Measure Mode 6 1 Introduction to Measure Mode Measure Mode is PPA Datalogger s all purpose measurement mode Measure mode is an intuitive way to log a wide range of parameters with several different metho
18. 7 11E 07 2 28E 07 8 57E 07 8 70E 07 8 44E 07 4 84E 07 1 17E 06 4 08E 07 2 63E 07 6 88E 07 1 06E 06 9 38E 07 1 21E 06 1 12E 06 1 32 06 1 21 06 2 44E 02 2 46E 02 2 45E 02 2 45E 02 2 45E 02 2 50E 02 2 45E 02 2 46E 02 2 45E 02 2 43E 02 2 47E 02 2 44E 02 2 46E 02 2 45E 02 2 41E 02 2 45E 02 2 45E 02 2 45E 02 2 48E 02 2 47E 02 2 47E 02 2 48E 02 2 49E 02 2 43E 02 2 44E 02 2 45E 02 2 46E 02 2 47E 02 2 48E 02 2 47E 02 2 49E 02 2 45E 02 2 46E 02 4 52E 02 4 52E 02 4 52E 02 4 52E 02 4 53E 02 4 52E 02 4 52E 02 4 52E 02 4 51E 02 4 51E 02 4 52E 02 4 51E 02 4 51E 02 4 51E 02 4 51E 02 4 51E 02 4 51E 02 4 51E 02 4 52E 02 4 52E 02 4 52E 02 4 51E 02 4 51E 02 4 51E 02 4 51E 02 4 50E 02 4 50E 02 4 50E 02 4 50E 02 4 50E 02 4 50E 02 4 50E 02 4 51E 02 G 4 81E 02 4 80E 02 4 82E 02 4 80E 02 4 84E 02 4 82bE 02 4 81E 02 4 81E 02 4 81E 02 4 82E 02 4 83E 02 4 82E 02 4 80E 02 4 80E 02 4 81E 02 4 81E 02 4 81E 02 4 82E 02 4 81E 02 4 80E 02 4 80E 02 4 81E 02 4 81E 02 4 84E 02 4 82E 02 4 82bE 02 4 82E 02 4 81E 02 4 81E 02 4 82E 02 4 80E 02 4 80E 02 4 79E 02 H 3 92E 02 3 93E 02 3 93E 02 3 93E 02 3 94E 02 3 95E 02 3 93E 02 3 93E 02 3 93E 02 3 92E 02 3 94E 02 3 92E 02 3 92E 02 3 92E 02 3 91E 02 3 92E 02 3 93E 02 3 93E 02 3 94E 02 3 93E 02 3 93E 02 3 93E 02 3 94E 02 3 93E 02 3 92E 02 3 93E 02 3 93E 02 3 93E 02 3 93E 02 3 93E 02 3 93E 02 3
19. set the Instrument into sweep mode Pressing START will begin an Interharmonics sweep and PPA Datalogger will wait for the sweep to complete Waiting for Results 46 E interharmonics direct to csv txt File Harmonic Frequency Inter Harmonic Voltage Inter Harmonic Current Inter Harmonic Voltage Ph2 Inter Harmonic Current Ph2 Inter Harmonic Voltage Ph3 Inter Harmonic Current Ph3 PPA Datalogger Software User Manual Once the sweep is complete PPA Datalogger will download the sweep data from the Instrument Downloading Results Estimated time remaining 0 Seconds And then a message will appear showing that the data has been downloaded Harmonics Results have been downloaded The results will not be shown within the software but can be exported to Excel If the Log to CSV parameter was ticked prior to the sweep then the CSV file will contain all sweep data for all Harmonics previously set Edit Format View Help 1 5 00000000E 000 2 78046355E 004 6 47684792E 005 4 35750932E 004 1 26775587E 004 3 89507040E 004 1 09264947E 005 2 1 00000000E 001 3 14630568E 004 5 68825053E 005 1 11963600E 004 1 40773773E 005 4 41970304E 004 5 062721 90E 005 3 1 50000000E 001 4 39865049E 004 2 46709096E 005 1 49734784E 004 2 25430413E 005 3 86940315E 004 1 22947822E 005 4 2 00000000E 001 2 95000616E 004 3 01554974E 005 3 51818744E 004 2 58624495E 005 1 97645044E 004 6 3361 3672E 005 5 2 50000000E 001 1 9600777
20. the Saved Config term in the dropdown menu To load a previously saved configuration into the Configuration Panel highlight Load and Click one of saved configurations Configure Display Measure Harmonics Scope Capture Connection poaz DDA4 serup Saved Config h Load k Load Test 1 Settings PPA5530 Open CSV File Save Load empty Settings Export Load empty Add Edit Equations Load empty ALARM REMOTE AUX Load empty Smooth L d f SYS MODE PROG a empty Load empty Load empty mumos REALTIME cue 554 fempty The software will upload the settings saved in that configuration and set up the Configuration Panel accordingly To ensure the instrument is setup with the settings that have just been loaded press the SET UP PPA button just above the Configuration Panel 15 PPA Datalogger Software User Manual 4 4 Exporting Configurations Click Configure and hover over the Saved Config term in the dropdown menu To export one of the saved configurations click the Export menu item Display Measure Harmonics Scope Captu Connection m F Saved Config h Load Open CAV File Save Settings Export Add Edit Equations Import The software will then display a list of saved configurations select the configuration to export and press
21. 0 0 00E 00 0 00E 00 0 00E 00 0 00E 00 0 00E 00 PPA Datalogger Software User Manual Contact Details If you require any further assistance with the operation of PPA Datalogger please do not hesitate to contact your local distributor or N4L on support newtons4th com 74
22. 00 28 900 12 11 00 29 217 13 11 00 29 537 14 11 00 29 859 15 11 00 30 177 16 11 00 30 497 17 11 00 30 817 18 11 00 31 137 19 11 00 31 460 20 11 00 31 778 21 11 00 32 147 22 11 00 32 419 23 11 00 32 739 24 11 00 33 058 25 11 00 33 378 26 11 00 33 698 27 11 00 34 018 28 11 00 34 338 29 11 00 34 658 30 11 00 34 979 31 11 00 35 297 32 11 00 35 617 33 11 00 35 937 34 11 00 36 257 35 11 00 36 580 oN TDW N Excel will place the CSV into the spreadsheet separated by column PPA Datalogger Software User Manual Date 06 10 2015 06 10 2015 06 10 2015 06 10 2015 06 10 2015 06 10 2015 06 10 2015 06 10 2015 06 10 2015 06 10 2015 06 10 2015 06 10 2015 06 10 2015 06 10 2015 06 10 2015 06 10 2015 06 10 2015 06 10 2015 06 10 2015 06 10 2015 06 10 2015 06 10 2015 06 10 2015 06 10 2015 06 10 2015 06 10 2015 06 10 2015 06 10 2015 06 10 2015 06 10 2015 06 10 2015 06 10 2015 06 10 2015 C 5 00E 01 5 00E 01 5 00E 01 5 00E 01 5 00E 01 5 00E 01 5 00E 01 5 00E 01 5 00E 01 5 00E 01 5 00E 01 5 00E 01 5 00E 01 5 00E 01 5 00E 01 5 00E 01 5 00E 01 5 00E 01 5 00E 01 5 00E 01 5 00E 01 5 00E 01 5 00E 01 5 00E 01 5 00E 01 5 00E 01 5 00E 01 5 00E 01 5 00E 01 5 00E 01 5 00E 01 5 00E 01 5 00E 01 D 4 17E 07 1 04E 06 4 77E 07 7 14E 07 6 77E 07 1 00E 06 8 40E 07 9 96E 07 7 17E 07 1 22 06 1 53E 07 7 88E 08 2 68E 08 1 71E 07 4 51E 07 5 80E 07 6 61E 07
23. 00 u 26 050 m Frequency PH1 Watts PH1 VA PH1 RMS Voltage PH1 jeu 0 1 2 3 6 7 8 9 4 7 n 0 0000 Time 5 76 och B Harmonic Mode s Graph Range 200mV 20mA 300mV 30mA 300mV 30mA 30mA Coupling ac dc Bandwidth Wide 100 Phase 1 Phase 2 Voltage Phase 3 H2 H40 Neutral J 100 Current H2 H40 B Scope Mode s Scope Image Voltage Range 1V Current Range 100mA Coupling ac dc Bandwidth Wide Phase 1 RH lt sss Phase 2 Phase 3 Voltage Neutral Current 10 000 ms div 18 PPA Datalogger Software User Manual B Capture Mode s Screenshot Voltage Range 1V Current Range 100mA Coupling ac dc Bandwidth Wide Phase 1 Phase 2 Phase 3 Voltage Neutral Current 10 000 ms div 5 2 Save to Bitmap Save to Bitmap allows you to save the current screen as a bmp image After the Save to Bitmap menu item has been clicked PPA Datalogger will need a file location to save the image to Note to save your bmp file remove the and replace with your file name before clicking on save D Save to Bitmap 9 uam Qc Libraries amp Pictures Search Pictures Organize New folder k pending releases Utilities k Product Manuals Pictures library Arrange by Folder Y Includes 2 locations Name Date 15 Size Rating ie Libraries j nda 10 06 2015 12 39 Documents J GIF 19 03 2014 17 01 a Music Jj N4L
24. 00067 53 6 0 00001 3 152 7 0 000076 111 2 0 00001 7 205 5 0 00001 4 307 7 13 43 02 419 3 3000 00000 0 000029 9 3 0 000005 75 0 0 000064 51 2 0 000004 42 2 0 0001 47 214 8 0 000005 57 9 0 000022 462 3 13 43 02 419 4 4000 00000 0 000035 1 1 5 0 000006 89 9 0 000047 37 6 0 000008 92 3 0 0001 38 202 5 0 000005 59 7 0 00001 6 345 3 13 43 02 419 5 5000 00000 0 000039 1 2 7 0 000002 25 9 0 000048 38 5 0 000007 76 8 0 000169 246 7 0 00001 8 216 0 0 00001 7 357 1 13 43 02 419 6 6000 00000 0 000028 9 3 0 000002 25 0 0 000046 36 8 0 000004 42 0 0 000822 1203 1 0 000006 79 8 0 00001 6 352 6 13 43 02 419 7 7000 00000 0 000040 1 3 2 0 000005 66 5 0 00001 2 9 3 0 000004 52 5 0 000169 246 8 0 000008 92 8 0 00001 5 316 1 13 43 02 419 8 8000 00000 0 000065 21 2 0 000007 104 3 0 000030 23 8 0 000003 37 2 0 0001 89 276 0 0 00001 2 1 44 9 0 000009 1 87 3 13 43 02 419 9 9000 00000 0 000058 1 9 0 0 000002 32 8 0 000084 66 8 0 000003 36 3 0 000046 66 6 0 00001 1 129 5 0 000008 1 76 0 13 43 02 419 10 10000 00000 0 000006 2 1 0 000006 83 3 0 000043 34 5 0 000003 34 1 0 0001 60 234 5 0 000008 95 2 0 000006 1 30 8 13 43 02 419 11 11000 00000 0 000032 1 0 5 0 000003 48 5 0 0001 25 100 0 0 000004 48 9 0 000044 64 7 0 00001 3 157 1 0 000034 736 0 13 43 02 419 12 12000 00000 0 000047 1 5 2 0 000001 21 2 0 000034 27 0 0 000008 94 0 0 000042 61 5 0 000005 60 6 0 000029 61 8 5 13 43 02 419 13 13000 00000 0 000046 1 5 1 0 000007 101 0 0 000031 24 6 0 000004 44 0 0 0001 35 1 96 9 0 000008 9
25. 002 1 26333442E 004 4 0046361 4E 006 2 00525625E 004 7 68533209E 006 1 19264005E 004 8 22653237E 006 55000000E 002 1 15468283E 004 4 71994281 E 006 1 61558622E 004 2 26938864E 005 1 65243109E 005 1 08150707E 005 60000000E 002 3 91089823E 004 6 25686516E 006 1 88777689E 004 3 01981345E 005 2 7697021 1E 004 7 60435796E 006 65000000E 002 2 0008571 4E 003 2 24687683E 005 1 89149007E 003 8 06740718E 005 2 66313553E 004 2 71171157E 005 70000000E 002 3 76685988E 004 8 25808092E 006 1 621 70827E 003 2 68596050E 005 1 48344599E 003 8 66760965E 005 75000000E 002 1 748881 77E 004 1 31755660E 005 4 03809827E 004 1 64740777E 005 1 60277821E 004 3 12729971E 005 80000000E 002 1 33996829E 004 4 17562114E 006 3 73645686E 004 1 33872527E 005 1 49502419E 004 7 30370812E 006 85000000E 002 1 89913437E 004 1 21112389E 005 6 44930406E 005 1 05725339E 005 1 23501057E 004 7 0604801 3E 006 90000000E 002 1 15818926E 004 8 51564982E 006 1 46436505E 004 1 26180239E 005 1 77319744E 005 7 3189221 4E 006 95000000E 002 1 09125162E 004 3 12983320E 006 1 2583541 7E 004 1 07685046E 005 3 31519404E 005 8 32465594E 006 40 2 00000000E 002 1 52055407E 004 2 26183329E 006 1 27685722E 004 7 17423245E 006 1 94276799E 005 6 9091 7659E 006 47 PPA Datalogger Software User Manual 7 4 Aircraft TVF105 Mode Only available with the PPA55xx Instrument Aircraft TVF105 Mode requires set up on the PPA55xx instrument first Press the APP button select aircraft TVF105 mode and h
26. 0390E 2 3 97260E 2 6 19050E2 6 09060E2 5 28970E2 0 00000E0 10 15 55 042 5 00000E1 1 42540E 8 2 61060E 2 4 49360E 2 4 80520E 2 3 96980E 2 4 65710E2 6 50360E2 8 42860E2 0 00000E0 10 15 56 043 5 00000E1 4 95780E 8 2 61060E 2 4 46310E 2 4 80420E 2 3 95930E 2 3 73220E2 6 38560E3 5 38440E2 0 00000E0 4 Ln 10 Col 52 The CSV file contains all the data read by PPA Datalogger line by line 35 PPA Datalogger Software User Manual 6 12 Overwrite CSV Mode Overwrite CSV Mode is one of Measure Mode s 5 measurement settings that reads data in from all the connected instruments and overwrites the data in a CSV file with the latest results Settings View Control a Software p x MULTILOG REAL TIME GRAPH Los Instrument zi ije M E Freeze Display ZERO 00 00 00 Data Settings RESULTS gt Manual Frequency PH1 Watts PH1 RMS Voltage PH1 RMS Voltage PH2 J Scheduled testing j Direct log to CSV RMS Voltage PH3 RMS Voltage SUM Voltage THD PH1 Voltage THD PH2 Voltage THD 3 Voltage THD SUM r 10 0000 High Speed Mode Enter Highspeed Mode The first thing to do when logging in Overwrite CSV mode is to set the file to log to by clicking in the white CSV File box bringing up a window to set the file name and location f Select file for CSV logging lt om SS f rT Computer Windows7 OS C PP
27. 0m 0 02 10 2015 13 30 Text Document 53 Libraries Eg Documents Music Pictures J Subversion B Videos IW Computer L Windows OS C f DVD Drive D 15 0 442 Ler at MY ALAS 2 Ae File name Export To CSVbt TTT wh X O aISI 5 Hide Folder s Select a file location for the data to be stored within and rename remembering to replace the with the file name and click on Save 40 PPA Datalogger Software User Manual 6 16 Exporting Data to Excel Export to Excel once the test has been stopped press the Export button in the bottom right corner of the Measure Window Export And ensure Export to Excel is selected choose the export format and press OK Export to Export to CSV Settings Standard C Engineering Scientific Example 0 123456 Excel will open with the time and each PPA s Multilog Parameters as columns f C D E F G 1 Time _ Frequency PH1 PPA1 Watts PH1 PPA1 RMS Voltage PH1 PPA1 RMS Voltage PH2 PPA1 RMS Voltage PH3 PPA1 RMS Voltage SUM PPA1 2 09 55 37 982 1000 00 0 0000006 747 0 025602 0 044609 0 048245 0 039487 3 09 55 38 282 1000 00 0 0000007749 0 025564 0 044577 0 048211 0 039451 4 09 55 38 681 1000 00 0 0000007888 0 025554 0 044605 0 048193 0 039451 2 09 55 39 081 1000 00 0 0000009917 0 025508 0 044639 0 048121 0 039423 6 09 55 39 481 1000 00 0 000000994535 0 025528 0 044623 0 048007 0 039386 7 0
28. 1 40E 2 2 261 30E2 3 14590E2 6 75640E2 0 00000E0 Ln 1 Col 1 The CSV file contains only the latest result that was received by PPA Datalogger 37 PPA Datalogger Software User Manual 6 13 Customizing Graph View The Measure Mode Graph can be customised to show up to 4 of the selected Multilog Parameters PPAI RESULTS None Watts PHL RMS Voltage PHL RMS Voltage PH RMS Voltage PH3 RMS Voltage SUM Time 5 Any of the graph lines can be reconfigured by clicking within the Parameter box Parameters can be reassigned a colour change or can be deselected by entering none PPA1 RESULTS 28 000 m 47 500 m a3 500 m Mane RMS Voltage F RMS Voltage P RMS Voltage P w And the graph can be scrolled along the X axis by using the Time Scroll Bar at the bottom of the graph to display the data from across the time period of the test 38 PPA Datalogger Software User Manual 6 14 Logging with multiple Instruments When measuring with multiple instruments ensure that each instrument has its own multilog setup s PPA4 l PHI PHZ PH3 SUM N Frequency w Watts F And if the measurement speed is set to Instrument interval ensure that each instrument is set to an appropriate speed setting wona ea Speed Fast w F Smoothing Normal While logging in either Real Time View or Graph View a new button appears View All which will
29. 1 84799545E 004 2 46296695E 005 16 3 20000000E 002 4 25763428E 005 8 99737643E 006 2 97488645E 004 1 93123124E 005 1 58352079E 004 2 53585167E 005 17 3 40000000E 002 1 52713852E 004 3 26464651E 005 4 05753031E 004 6 93616457E 005 2 90316530E 004 2 59648950E 005 18 3 60000000E 002 2 86447350E 004 3 13261990E 005 2 3655081 2E 004 9 06099740E 006 3 52322124E 004 1 52877474E 005 19 3 80000000E 002 1 26841245E 004 4 0197861 4E 005 2 86555849E 004 1 52457651E 005 1 81555981 E 004 2 52770551 E 005 20 4 00000000E 002 1 47725921E 004 8 06951721E 006 1 74047658E 004 7 56051304E 006 2 06131954E 004 3 33151547E 005 21 4 20000000E 002 1 47507759E 004 1 11526897E 005 2 34859297E 004 9 05976049E 006 3 07322945E 004 5 52798738E 005 22 4 40000000E 002 3 43119260E 004 1 4641 7879E 005 1 737261 1 9E 004 2 11348233E 005 1 48193445E 004 2 39731453E 005 23 4 60000000E 002 5 04436903E 004 2 46980635E 005 1 63131859E 004 5 10951504E 005 2 37609260E 004 5 08383964E 005 24 4 80000000E 002 6 05301 932E 004 9 35775461E 006 3 33484728E 004 4 12830268E 005 4 24657483E 004 4 98575973E 005 25 5 00000000E 002 1 85102038E 003 4 38973075E 005 2 16477737E 003 1 34960283E 004 1 18724070E 003 7 38886883E 005 26 5 20000000E 002 5 8083981 3E 004 1 43876823E 005 1 78039074E 003 9 36684664E 005 1 05110742E 003 1 28643820E 004 27 5 40000000E 002 2 58034561E 004 5 61966590E 006 5 17151318E 004 2 32128077E 005 3 70015856E 004 1 80549396E 005 28 5 60000000E 002 7 39316456E 005 2 8874841 5E 005 1 84957869
30. 1 second 6 3 High speed Mode High speed Mode is a measurement mode that records data Straight to the PC s RAM allowing for very fast measurements that can go as fast as 200 results per second It is completely optional however it is the best way to read data reliably at high speeds To be able to reach such fast speeds however there are a few limitations to using High speed Mode which PPA Datalogger will inform you of when you enter High speed Mode for the first time after opening the software PPA Data Logger high speed mode you cannot Log Manually or Direct to CSV Measure more than 18 Multilog Parameters Measure multilog parameters that are not basic Power RMS values Measure with PPA2 PPAS or PPA4 Maximise the software while logging Show or hide the config panel while logging Log Sum multilog parameters It is not recommended to log in high speed mode for longer than 10 minutes Enter High Speed Mode md High speed Mode only works with Log Real Time mode limits how many parameters can be logged which parameters are available and it is only available for logging on one PPA 22 PPA Datalogger Software User Manual Due to the high amount of data PPA Datalogger will be recording while in High speed Mode it is recommended that logging is kept to at most 10 minutes however computers with more RAM will be able to keep logging for longer High Speed Mode Enter Highspeed Mode When me
31. 3 of 3 This screen lets you select each column and set the Data Format Column data format C General General converts numeric values to numbers date values to dates and all Do not import column skip Data preview Tatta PPAl BMS Voltage 4 16950E 7 44150E Z 1 04010E 6 40040E 2 4 76750E 7 44690E 2 71 PPA Datalogger Software User Manual Ensure the Time column is set Text and the Date column if it was exported is set to Date DMY If the imported CSV is from a manual log set the Notes column to Text too Leave the rest of the columns as General and Excel will match them to number formats If the CSV was exported using European Format click the Advanced button Advanced Text Import Settings Settings used to recognize numeric data Decimal separator B Thousands separator B Note Numbers will be displayed using the numeric settings specified in the Regional Settings control panel Ensure the Decimal Separator is set to a comma and the thousands separator is set something other than a comma and press OK Finish is Press the Finish button then press OK on the next window or set a new location for the data to be imported to Import Data Where do you want to put the data 8 Existing worksheet 72 FI 88193685 Time 11 00 26 451 11 00 26 657 11 00 26 976 11 00 27 296 11 00 27 616 8 11 00 27 937 9 11 00 28 256 10 11 00 28 578 11 11
32. 4 1 09326647E 005 3 6 00000000E 001 1 57412374E 004 1 09268440E 005 6 79068267E 004 3 24035063E 005 4 60074749E 004 2 59057852E 005 4 8 00000000E 001 3 7680845 7E 004 7 47857848E 005 6 21788204E 004 2 05096730E 005 6 18731603E 004 2 15051405E 005 5 1 00000000E 002 1 48783205E 004 3 10060568E 005 2 43240036E 004 8 97693681E 005 3 47766560E 004 5 50351106E 005 6 1 20000000E 002 4 37057577E 004 5 100941 05E 005 1 73327047E 004 5 04560885E 005 2 13672640E 004 5 08702942E 005 7 1 40000000E 002 5 72022982E 004 5 13936975E 005 5 84484078E 004 7 851 1 5408E 005 3 04413494E 004 4 00287681E 005 8 1 60000000E 002 1 99863315E 003 2 19128269E 005 1 96969509E 003 1 27945328E 004 1 38914026E 003 1 06687308E 004 9 1 80000000E 002 1 44169852E 003 1 20539335E 005 2 46639922E 003 5 74750593E 005 1 16887316E 003 9 87998210E 005 10 2 00000000E 002 7 96472654E 004 3 84766026E 005 9 70290042E 004 1 7432641 5E 005 4 09129076E 004 6 78179786E 005 11 2 20000000E 002 3 44428234E 004 2 49128207E 005 7 08488747E 004 3 42679559E 005 4 16411553E 004 4 56856214E 005 12 2 40000000E 002 2 63938680E 004 2 66967982E 005 1 76499365E 004 2 04104290E 005 2 56098807E 004 2 32769526E 005 13 2 60000000E 002 1 97635498E 004 1 9741361 0E 005 5 60775399E 004 4 60448209E 005 1 41235301E 004 4 04755119E 005 14 2 80000000E 002 3 93807888E 004 1 74809538E 005 7 83238793E 005 5 48810349E 005 3 601 745 70E 004 3 64700099E 005 15 3 00000000E 002 1 52758555E 004 2 57700449E 005 2 24230578E 004 2 01507064E 005
33. 419 25 25000 00000 0 000028 9 2 0 000002 35 3 0 000070 55 8 0 000004 50 6 0 000059 86 2 0 00001 1 134 9 0 00001 5 330 8 13 43 02 419 26 26000 00000 0 000057 1 8 5 0 000002 32 7 0 000091 72 7 0 000025 326 8 0 000027 39 0 0 000009 1 1 4 1 0 000024 509 0 13 43 02 419 27 27000 00000 0 00001 9 6 2 0 000003 40 4 0 000040 32 0 0 000025 324 7 0 000247 361 9 0 000005 65 8 0 00001 9 403 8 13 43 02 419 28 28000 00000 0 00001 9 6 4 0 000004 60 7 0 000065 51 8 0 00001 1 1 42 6 0 000055 80 7 0 000006 78 8 0 00001 2 258 9 13 43 02 419 29 29000 00000 0 000048 1 5 7 0 000004 64 0 0 000092 73 2 0 000008 1 01 1 0 000091 133 5 0 000022 270 7 0 00001 8 390 5 13 43 02 419 30 30000 00000 0 000059 1 9 3 0 000004 52 9 0 000050 40 3 0 00001 3 173 4 0 000116 170 0 0 00001 7 209 6 0 000022 468 8 13 43 02 419 31 31000 00000 0 000042 1 3 7 0 00001 3 184 5 0 000072 57 7 0 000008 1 09 3 0 000232 339 9 0 000001 9 2 0 00001 8 391 3 13 43 02 419 32 32000 00000 0 000054 1 7 5 0 000007 108 0 0 000009 7 5 0 00001 5 200 4 0 000265 387 2 0 000006 68 0 0 000009 1 87 2 13 43 02 419 33 33000 00000 0 000078 25 6 0 000006 82 2 0 00001 3 10 7 0 00001 6 204 6 0 0001 44 210 2 0 000006 69 4 0 000008 1 77 4 13 43 02 419 34 34000 00000 0 000003 1 1 0 000003 47 5 0 000049 39 2 0 00001 1 150 3 0 000118 172 5 0 000008 1 04 0 0 000006 1 30 9 13 43 02 419 35 35000 00000 0 000068 22 3 0 000005 71 3 0 000074 59 3 0 000007 97 7 0 0001 32 193 1 0 00001 0 127 4 0 000007 1 60 5 13 43 02 419 36 36000 00000 0 00041
34. 5 00000E1 5 65380E 7 2 601 20E 2 4 50200E 2 4 80940E 2 3 97090E 2 2 801 40E2 9 89630E2 1 25070E3 0 00000E0 10 15 43 043 5 00000E1 5 05470E 7 2 60500E 2 4 501 20E 2 4 80530E 2 3 97050E 2 2 35170E2 1 18420E3 6 51020E2 0 00000E0 10 15 44 042 5 00000E1 4 45640E 7 2 60870E 2 4 51000E 2 4 80310E 2 3 97390E 2 2 06580E2 4 13770E2 1 22060E3 0 00000E0 10 15 45 043 5 00000E1 3 97330E 7 2 61050E 2 4 49800E 2 4 81 370E 2 3 97410E 2 1 77050E2 8 54290E2 4 491 40E2 0 00000E0 10 15 46 048 5 00000E1 1 53950E 7 2 61 490E 2 4 49450E 2 4 80660E 2 3 97200E 2 4 14680E2 8 17040E2 4 67330E2 0 00000E0 10 15 47 042 5 00000E1 1 76360E 7 2 62780E 2 4 491 70E 2 4 80320E 2 3 97420E 2 5 83780E2 1 13330E3 5 15230E2 0 00000E0 10 15 48 045 5 00000E1 3 27510E 7 2 62210E 2 4 49590E 2 4 80330E 2 3 97380E 2 4 48610E2 6 75660E2 4 23770E2 0 00000E0 10 15 49 043 5 00000E1 3 02630E 7 2 62170E 2 4 49350E 2 4 80470E 2 3 97330E 2 3 76700E2 5 51280E2 6 60200E2 0 00000E0 10 15 50 048 5 00000E1 2 44540E 7 2 61520E 2 4 48410E 2 4 80470E 2 3 96800E 2 2 62470E2 5 88320E2 7 77560E2 0 00000E0 10 15 51 044 5 00000E1 2 49880E 7 2 61620E 2 4 48270E 2 4 801 80E 2 3 96690E 2 2 38160E2 5 65600E2 1 31070E3 0 00000E0 10 15 52 044 5 00000E1 1 45410E 7 2 61450E 2 4 48430E 2 4 81 380E 2 3 97090E 2 1 94550E2 5 00660E2 5 50010E2 0 00000E0 10 15 53 043 5 00000E1 8 30250E 8 2 61310E 2 4 49330E 2 4 81040E 2 3 97230E 2 2 07300E2 4 23400E2 4 79100E2 0 00000E0 10 15 54 047 5 00000E1 6 55150E 8 2 61020E 2 4 50380E 2 4 8
35. 7 1 0 000032 692 7 13 43 02 419 14 14000 00000 0 000029 9 6 0 000004 54 6 0 000047 37 8 0 000004 50 7 0 000202 295 4 0 000008 94 4 0 000005 1 03 2 13 43 02 419 15 15000 00000 0 000093 30 4 0 000004 56 3 0 000080 63 9 0 000002 26 9 0 000076 111 1 0 00001 3 159 0 0 000034 725 7 13 43 02 419 16 16000 00000 0 000067 21 9 0 000001 1 3 4 0 000065 52 1 0 000002 24 5 0 000204 297 9 0 0000093 1 13 1 0 00001 8 389 4 13 43 02 419 1 7 17000 00000 0 0001 05 34 5 0 000003 41 6 0 000124 99 4 0 000006 69 4 0 000125 182 6 0 00001 0 123 9 0 000044 941 9 13 43 02 419 18 18000 00000 0 000053 1 7 2 0 000004 63 0 0 000039 31 0 0 000005 62 9 0 00001 5 22 5 0 000006 71 8 0 00001 8 382 6 13 43 02 419 19 19000 00000 0 000036 1 1 8 0 000005 78 5 0 000075 60 0 0 000006 69 1 0 000269 393 1 0 00001 2 1 42 0 0 00001 3 285 7 13 43 02 419 20 20000 00000 0 000065 21 2 0 000003 40 3 0 000068 54 4 0 000002 21 9 0 000063 92 6 0 00001 5 180 9 0 000023 486 4 13 43 02 419 21 21000 00000 0 000051 16 5 0 000003 40 9 0 000090 71 9 0 000004 48 2 0 00021 1 309 3 0 000008 1 02 8 0 00001 5 316 1 13 43 02 419 22 22000 00000 0 00005 7 1 8 7 0 000001 9 8 0 000043 34 0 0 00001 7 216 7 0 000078 1 13 5 0 000009 107 2 0 000027 580 5 13 43 02 419 23 23000 00000 0 000040 1 3 1 0 000006 87 3 0 0001 20 96 1 0 000009 1 1 9 0 0 000072 105 0 0 000009 1 06 9 0 000008 165 7 13 43 02 419 24 24000 00000 0 00001 9 6 1 0 00001 0 151 0 0 0001 03 81 9 0 00001 7 224 7 0 000031 45 8 0 000006 76 0 0 00001 7 369 9 13 43 02
36. 8 1 36 9 0 00001 0 1 37 9 0 0001 28 102 3 0 000057 745 9 0 000295 432 2 0 000009 1 09 4 0 000066 1 418 7 13 43 02 419 37 37000 00000 0 000044 1 4 3 0 000005 75 7 0 000068 54 0 0 000004 51 3 0 0001 85 271 1 0 000006 70 3 0 000006 1 35 2 13 43 02 419 38 38000 00000 0 000067 21 8 0 000005 72 2 0 000083 66 2 0 00001 2 161 7 0 000080 116 6 0 000006 72 8 0 00001 3 285 6 13 43 02 419 39 39000 00000 0 000049 1 6 1 0 000006 89 0 0 00001 8 1 4 5 0 000006 84 7 0 000079 116 0 0 00001 0 129 1 0 00001 6 334 4 13 43 02 419 40 40000 00000 0 000067 21 9 0 000001 12 8 0 000065 51 8 0 00001 9 246 1 0 00021 7 31 7 9 0 00001 6 202 9 0 00001 6 341 4 Alternatively selecting Export to Excel will display all Harmonics data received by PPA Datalogger within an Excel report 45 PPA Datalogger Software User Manual 7 3 nterharmonics Sweep Only available with the PPA45 55xx Instruments To Setup Interharmonics Sweep Mode press the MODE configuration button APP murum SYS MODE Set Operating mode to Harmonic Analyser set Computation to Interharmonics Sweep and configure all other Harmonic parameters as required To confirm the settings send them to the Instrument using the SET UP PPA button Configuration Harmoni Analyzer Operating Mode Harmonic Analyzer Computation internarniornc eer Frequency Step Selected Harmonic I Interharmonic Sweep Harmonics Control CTART PPA Datalogger will then
37. 8000000E 003 5 67613170E 005 2 74388294E 005 1 94651 773E 004 3 20400577E 005 1 04128267E 004 7 50873733E 006 55 1 10000000E 003 1 72480708E 004 3 00326428E 006 7 73963984E 005 2 26643751E 005 2 9912171 9E 004 7 22858385E 006 56 1 12000000E 003 1 44112390E 004 2 19614303E 005 1 01443846E 004 7 079041 1 0E 006 1 95313478E 004 7 20124808E 006 57 1 14000000E 003 4 96144057E 005 2 57760403E 005 1 09067187E 004 1 41589262E 005 9 56095755E 005 3 83156294E 006 58 1 16000000E 003 2 45753676E 004 2 24064570E 005 2 81035900E 004 6 36703335E 005 1 88249862E 004 1 06840162E 005 59 1 18000000E 003 1 07779913E 003 5 24563948E 005 1 14879571E 003 6 501 80737E 005 4 33691 777E 004 1 38813339E 005 60 1 20000000E 003 1 81380194E 004 1 13028073E 005 5 76510094E 004 3 88771296E 005 5 99818304E 004 5 96427126E 005 61 1 22000000E 003 1 29557913E 004 2 44962284E 005 2 34795036E 004 2 20569200E 005 2 92216893E 004 4 39299620E 005 62 1 24000000E 003 1 10767432E 004 2 88317970E 005 3 16762365E 004 2 92745535E 005 1 90321356E 004 1 74033921E 005 63 1 26000000E 003 3 94643284E 005 2 64910923E 005 1 13297836E 004 1 41695346E 005 1 4692801 1 E 004 4 92952531E 005 4 49 wlalulaliulsalwlr PPA Datalogger Software User Manual Exporting Harmonics to Excel When exporting to Excel PPA Datalogger will come up with a brief Progress Window telling you how long the export will take Exporting Pages Estimated time remaining 12 Seconds EL x When all the resul
38. 880E2 1 80900E3 0 00000E0 10 15 30 049 5 00000E 1 1 75710E 7 2 61970E 2 4 491 80E 2 4 80320E 2 3 97160E 2 3 24510E2 7 97260E3 8 47080E2 0 00000E0 10 15 31 0445 6 48720E 7 2 62060E 2 4 48430E 2 4 79890E 2 3 96790E 2 6 50650E2 6 00930E2 1 08970E3 0 00000E0 10 15 32 043 5 00000E1 5 68560E 7 2 61840E 2 4 48520E 2 4 801 70E 2 3 96840E 2 5 67280E2 6 62230E2 1 21830E3 0 00000E0 10 15 33 043 5 00000E1 3 23180E 8 2 60750E 2 4 50240E 2 4 79930E 2 3 96970E 2 2 76310E2 6 66070E2 6 89960E2 0 00000E0 10 15 34 048 5 00000E1 5 37630E 7 2 58450E 2 4 51050E 2 4 80700E 2 3 96730E 2 3 65590E2 8 53290E2 9 98980E2 0 00000E0 10 15 35 073 5 00000E1 3 81560E 7 2 60880E 2 4 51100E 2 4 80160E 2 3 97380E 2 6 70380E2 3 45970E2 1 66860E3 0 00000E0 10 15 36 042 5 00000E1 3 85610E 7 2 60840E 2 4 51220E 2 4 79910E 2 3 97320E 2 4 85570E2 3 56730E3 2 33910E3 0 00000E0 10 15 37 042 5 00000E1 3 10760E 7 2 60680E 2 4 50280E 2 4 79990E 2 3 96980E 2 3 79490E2 5 39320E2 3 06500E3 0 00000E0 10 15 38 048 5 00000E1 3 42570E 7 2 61080E 2 4 50130E 2 4 79530E 2 3 96910E 2 2 65130E2 5 41720E2 7 23080E2 0 00000E0 10 15 39 044 5 00000E1 1 89090E 7 2 61520E 2 4 49700E 2 4 79660E 2 3 96960E 2 8 30860E2 5 91150E2 6 83770E2 0 00000E0 10 15 40 043 5 00000E1 7 76580E 7 2 63190E 2 4 50880E 2 4 81 980E 2 3 98680E 2 4 48730E2 7 83760E2 7 44780E2 0 00000E0 10 15 41 043 5 00000E 1 7 69690E 7 2 59540E 2 4 50150E 2 4 81770E 2 3 97150E 2 3 73770E2 3 12240E2 6 501 30E2 0 00000E0 10 15 42 048
39. 9 55 39 880 1000 00 0 0000010885 0 025495 0 044508 0 04801 0 039338 8 09 55 40 280 1000 00 0 000001016535 0 025526 0 04459 0 048003 0 039373 3 09 55 40 650 1000 00 0 0000011603 0 025532 0 044572 0 047958 0 039354 10 09 55 41 081 1000 00 0 0000012 787 0 025562 0 044419 0 047923 0 039301 11 09 55 41 480 1000 00 0 0000012518 0 025521 0 044303 0 047952 0 039259 12 09 55 41 880 1000 00 0 0000012507 0 025482 0 04437 0 047961 0 039271 13 09 55 42 280 1000 00 0 0000013 703 0 025459 0 044535 0 047982 0 039325 14 09 55 42 680 1000 00 0 0000013585 0 025468 0 044614 0 047962 0 039348 15 09 55 43 079 1000 00 0 0000013337 0 025472 0 044754 0 047949 0 039392 16 09 55 43 482 1000 00 0 0000013287 0 025462 0 044545 0 04794 0 039316 17 09 55 43 880 1000 00 0 0000013056 0 025456 0 044569 0 04793 0 039319 ls 09 55 44 250 1000 00 0 0000013819 0 025445 0 044659 0 047962 0 039355 19 09 55 44 680 1000 00 0 0000014344 0 025446 0 044685 0 047935 0 039355 20 09 55 45 080 1000 00 0 0000013468 0 025479 0 044655 0 047929 0 039354 21 09 55 45 480 1000 00 0 0000012508 0 0254 7 0 044462 0 047881 0 039271 22 09 55 45 879 1000 00 0 0000011659 0 025511 0 044482 0 04792 0 039304 41 PPA Datalogger Software User Manual 7 Harmonics Mode 7 1 Setting up in Harmonics Mode To switch the PPA Datalogger and the connected instruments to Harmonics Mode press the Harmonics menu term at the top of PPA Datalogger Configure Display Measure
40. 92E 02 3 92E 02 9 18E 02 6 90E 02 1 73E 03 9 74E 02 6 47E 02 3 65E 02 2 19E 03 1 11E 03 5 07E 02 9 86E 02 5 22E 02 1 81E 03 3 79E 02 1 18E 03 1 08E 03 1 10E 03 7 90E 02 5 39E 02 5 20E 02 3 42E 02 3 08E 02 4 17E 02 3 40E 02 5 23E 02 1 44E 03 1 21E 03 8 30E 02 4 37E 02 8 50E 02 3 66E 03 9 20E 02 3 99E 02 8 30E 02 2 77E 03 1 41E 03 3 47E 03 1 63E 03 1 49E 03 8 44E 02 8 47E 02 9 91E 02 9 23E 02 1 62E 03 3 95E 03 1 23E 03 9 62E 02 5 15E 02 4 74E 02 3 86E 02 3 67E 02 6 06E 02 6 57E 02 6 38E 02 7 72E 02 6 32E 02 7 54E 02 9 12E 02 8 67E 02 6 77E 02 7 66E 02 1 08E 03 1 53E 03 2 11E 03 1 96E 03 2 11E 03 5 24E 02 3 58E 02 9 58E 02 4 03E 02 1 00E 03 5 88E 02 8 12E 02 6 01E 02 5 75E 02 4 58E 02 7 71E 02 4 36E 02 6 55E 02 6 68E 02 5 98E 02 1 36E 03 1 33E 03 9 96E 02 5 36E 02 3 67E 02 3 71E 02 3 23E 02 3 02E 02 3 15E 02 2 03E 03 1 84E 03 1 00E 03 7 26E 02 1 22E 03 7 17E 02 1 28E 03 3 13E 03 7 07E 02 5 39E 02 73 Frequency PH1PPA1 Watts PH1PPA1 RMS Voltage PH1PPA1 RMS Voltage PH2 PPA1 RMS Voltage PH3 PPA1 RMS Voltage SUM PPA1 Voltage THD PH1PPA1 Voltage THD PH2 PPA1 Voltage THD PH3 PPA1 Voltage THD SUM PPA1 0 00E 00 0 00E 00 0 00E 00 0 00E 00 0 00E 00 0 00E 00 0 00E 00 0 00E 00 0 00E 00 0 00E 00 0 00E 00 0 00E 00 0 00E 00 0 00E 00 0 00E 00 0 00E 00 0 00E 00 0 00E 00 0 00E 00 0 00E 00 0 00E 00 0 00E 00 0 00E 00 0 00E 00 0 00E 00 0 00E 00 0 00E 00 0 00E 0
41. 9E 004 2 93062767E 005 1 86383957E 004 3 11909243E 005 2 87781004E 004 2 70240125E 005 6 3 00000000E 001 1 08945998E 004 3 77292163E 005 1 71110034E 004 4 97825677E 005 6 80952799E 005 5 881 79682E 006 7 3 50000000E 001 1 33932568E 004 3 60928825E 005 2 28477642E 004 4 34434623E 005 1 67282065E 004 3 21365660E 005 8 4 00000000E 001 1 77535228E 004 1 10536203E 005 2 04596668E 004 1 46763923E 005 1 43445563E 004 1 68798433E 005 9 4 50000000E 001 1 56173948E 004 1 38516953E 006 2 13532941E 004 1 28720712E 005 8 17022519E 005 1 34172442E 005 10 5 00000000E 001 3 55191878E 005 9 20468301 E 006 1 85559737E 004 1 07981 759E 005 1 16097974E 004 2 34588224E 005 11 5 50000000E 001 5 20974281 E 005 1 31635461E 005 1 13173388E 004 9 61 798651 E 006 3 46041634E 005 1 42161589E 005 12 6 00000000E 001 2 78524531E 005 1 18476310E 005 1 67130260E 004 7 67632446E 006 2 16437271E 004 2 06912810E 005 13 6 50000000E 001 2 15403736E 004 1 44398946E 005 2 02081 166E 004 5 59425098E 006 5 17200097E 005 1 81728392E 005 14 7 00000000E 001 1 3656681 4E 004 1 4206831 1E 005 2 9838091 0E 005 1 53646688E 005 1 37397088E 004 1 51428976E 005 15 7 50000000E 001 1 97526067E 004 1 21039629E 005 1 28661981E 004 4 03940066E 006 1 73007604E 004 1 49835978E 005 16 8 00000000E 001 1 75704481E 004 1 30985281 E 005 5 53618302E 005 8 23639857E 006 2 38430221 E 004 1 698211 42E 005 17 8 50000000E 001 2 74032820E 004 1 89783459E 005 1 067081 47E 004 1 78006012E 005 8 21722206E 005 1 59360352E 005
42. A Datalogger Log Files gt Search PPA Datalogger Log F Organize v New folder k pending releases Date modified Utilities k No items match your search 19 Libraries Documents Music i Pictures c Subversion im Videos W Computer t Windows OS C f DVD Drive D 15 0 442 Filename latest result txt Save as type a Hide Folders Once the name and location are set press Save and return to the data logging screen 36 PPA Datalogger Software User Manual To commence the test press the START button and PPA Datalogger will read data from all connected instruments Each line of data is displayed in Real Time view and the CSV file is overwritten with the latest result Each time a result comes in the Elapsed Log Time updates Settings View Control m Elapsed Log Time i Freeze Displa 7ERC 00 00 07 PPA1 RESULTS earl Frequency PH1 Watts PH1 RMS Voltage PH1 RMS Voltage PH2 RMS Voltage PH3 RMS Voltage SUM Voltage THD PH1 Voltage THD PH2 Voltage THD PH3 Voltage THD SUM High Speed Mode Pressing the STOP button ends the log The CSV file can be changed to start a new test or pressing START again without changing the file will continue to overwrite the original CSV file _ latest result txt Notepad m cH File Edit Format View Help li 0 50 33 221 5 00000E1 1 37690E 6 2 61320E 2 4 481 40E 2 4 78980E 2 3 96
43. Auxiliary Device to be ADIA4O CONTROL PPAL Configuration Auxiliary Control ACQU COUPLING RANGE Master Slave Disabled DATALOG APP MATHS AQ 20 way I Thermocouple J ALARM REMOTE AUX b rj ADI Adjust Mone SYS MODE PROG And then set any other options you require such as which thermocoupling calculation you want to use and whether ADI adjust is required 10 2 Adding ADI Inputs To add an ADI input to your multilog selection press the Add ADI Input button Pil riil aaa GEG 2am IGE GAG u 3 ADI Output Function Output 22S F B BBB 5 5 3 aaa Ila 56 PPA Datalogger Software User Manual This then brings up the ADI Input window You ll want to select the channel you ve wired your Input to red enter the unit you want Datalogger to display next to the value it reads green and give it any necessary scale factor blue Optionally you can give the ADI Input a name that will be displayed as the title for the Input on Real Time mode and the name used on graphs and when you export ADI Input Name Air Pressure optional Scale it 3 1 000ED i When you re done setting your ADI Input press OK and it will be added to the multilog selection box just like any other Multilog parameter Selected Items Function Channel Frequency PH1 Watts VA PH1 RMS Voltage PH1 When you re done adding your othe
44. CSV file in addition to the Data Log Pressing the Start button begins the testing all data is presented at the interval speed central START CLEAR LOG And the Real Time screen updates with each set of results taken from the PPA PPA1 RESULTS Frequency PH1 Watts PH1 RMS Voltage PH1 RMS Voltage PH2 RMS Voltage PH3 RMS Voltage SUM Voltage THDPH1 Voltage THD PH2 Voltage THD PH3 Voltage THD SUM 28 PPA Datalogger Software User Manual While logging in Auto Append mode the timer displays a time that counts down until the next piece of data is added to the Data Log Control SEs REAL TIME GRAPH LOG PAUSE CLEAR LOG Instrument J KI 2 PM Freeze Display ZERO Time Frequency PHL PPAL Watts PHL PPAL RMS Voltage PHLPPAL RMS Voltage PH PPAl RMS Voltage 3 PPAL RMS Voltage SUM PP Settings View Control p REAL TIME GRAPH LOG PAUSE CLEAR LOG Instrument HE Freeze Display ZERO Time Frequency PHL PPAL Watts PHlPPAI RMS Voltage PHLPPAL RMS Voltage PH2 PPAL RMS Voltage PH3 PPAl RMS Voltage SUM PPA 23 08 57 53 232 50000 Hz 584 40 nW 26438 mV 45715 mV 47 270 mV 38828 mV When not using Auto Append mode data is only added to the Data Log when the APPEND button is activated Settings View Control PPA1 RESULTS Frequency PH1 Watts PH1 RMS Voltage PH1 RMS Voltage PH2 RMS Voltage PH3 RMS Voltage SUM Voltage THD PH1 Voltage THD PH2 Voltage THD PH3 A Voltage THD SUM
45. E 004 7 6812721 1E 006 7 49853207E 005 3 72512150E 005 29 5 80000000E 002 1 0129681 3E 004 5 36302832E 006 4 000891 93E 004 2 78777734E 005 2 71413010E 004 1 52321300E 005 30 6 00000000E 002 2 22179340E 004 1 66736572E 006 2 80775 1 30E 004 1 90754654E 005 1 41323078E 004 4 01585712E 005 31 6 20000000E 002 1 70342391E 004 4 50380030E 005 1 59445452E 004 2 77984946E 005 2 8644641 9E 004 1 14826980E 005 32 6 40000000E 002 1 63677149E 004 1 83540687E 005 3 36352387E 005 3 82413855E 005 1 20753655E 004 3 34102660E 005 33 6 60000000E 002 2 51345336E 004 4 6461 1803E 005 2 65301 205E 004 2 42785027E 005 3 1982641 7E 004 7 79784750E 006 34 6 80000000E 002 4 20039520E 004 7 12079782E 006 5 26475720E 004 1 28493848E 005 4 4541 0609E 004 4 75755660E 005 35 7 00000000E 002 8 4878061 9E 005 1 58281182E 005 6 18794002E 005 1 97888585E 005 9 20103630E 005 1 03247294E 005 36 7 20000000E 002 1 38351694E 004 1 21724443E 005 3 57448123E 004 1 14109425E 005 1 12535548E 004 2 40607478E 005 37 7 40000000E 002 1 82984862E 004 6 45167893E 006 1 14635448E 004 6 12505391E 006 5 13058039E 005 4 62971366E 006 38 7 60000000E 002 2 99538486E 004 1 42108183E 005 1 62000535E 004 2 20645161E 005 1 60826370E 004 3 89746274E 005 39 7 80000000E 002 1 62279932E 004 1 44348160E 005 3 23845074E 004 3 0395691 3E 005 2 86428723E 004 2 03259988E 005 40 8 00000000E 002 2 33276747E 004 9 48191 155E 006 1 40632503E 004 3 93210794E 005 1 65900914E 004 2 60733941E 005 41 8 20000000E 002 2 18108296E 004 1
46. Export mum Test 1 Settings PPAS530 The software will then ask for a location to save the configuration Once the location is set press OK to export the selected configuration to the chosen location as a cfg file T d Computer Windows7_OS C PPA Datalogger Configurations Search PPA Datalogger Confi Organize w New folder bo pending releases F Date modified Type Utilities k T No items match your search Libraries ES Documents Music i Pictures S Subversion B Videos IW Computer L Windows7 OS C f DVD Drive D 15 0 442 File name I3 Sul SE Kas Save as type Config Files cfg lt Hide Folders 16 PPA Datalogger Software User Manual 4 5 Importing Configurations Click Configure and hover over the Saved Config term in the dropdown menu To import a configuration from a cfg file click the Import menu item Configure Display Measure Harmonics Scope Capt Connection poaa pea Saved Config z Load h Open CSV File Save Settings Export Add Edit Equations import Navigate to and select the cfg file to import and press Open v Computer Windows7 OS C PPA Datalogger Configurations v Search PPA Datalogger Confi wy 99 g Organize v New folder k Andrew Tyler gt Name Date modified Type k standards X pending releases Utilities k Product Manuals
47. Frequency PHL PPAL Watts PH1 PPAL RMS Voltage PHL PPAL RMS Voltage PHZ PPAl RMS Voltage PH3 PPAl RMS Voltage SUM PPAL 50 000 Hz 406 51 nW 25587 mV 45231 mV 47 304 mV 40074 mV Pressing Pause will stop the PPA Datalogger software from reading data from the Instrument The test can be resumed by pressing the Start button again alternatively pressing Clear Log will clear any data within the Data Log Control START CLEAR LOG 29 PPA Datalogger Software User Manual 6 9 Log Real Time Mode Log Real Time one of PPA Datalogger s 5 measurement settings is the default mode which records each result read from the connected Instrument to the Data Log Logging in Log Real Time mode is simple press the START button and let PPA Datalogger record the data Control Interval s LOG START CLEAR LOG none nt ZERO 5 View MULTILOG REAL TIME GRAPH Elapsed Log Time 00 00 00 PPA1 RESULTS IL Frequency PH1 Watts PH1 RMS Voltage PH1 RMS Voltage PH2 Direct log to CSV Overwrite CSV RMS Voltage PH3 RMS Voltage SUM Voltage THD PH1 Voltage THD PH2 Select File Voltage THD PH3 Voltage THD SUM 0 0000 0 0000 NN High Speed Mode Enter Highspeed Mode The Elapsed Log Time updates every time a new result is read from all connected instruments and entered into the Data Log Settings View Control Elapsed Log Time ee In
48. KB 63 612 KB jE Computer Windows7_05 C f DVD Drive D 15 0 4420 C Public NNNewtons4thSE E Lenovo Recovery Q E Daboyz S4 i Network Text Files prn txt csv File name measure log plus date txt Excel will then ask if the data should be imported as Delimited file or Fixed Width Ensure Delimited is selected and press Next Text Import Wizard Step 1 of 3 The Text Wizard has determined that your data is Delimited If this is correct choose Next or choose the data type that best describes your data Original data type Choose the file type that best describes your data Characters such as commas or tabs separate each field Excel will then ask what the data in the file is delimited by 70 PPA Datalogger Software User Manual If the file was Exported in Standard Format then select Comma if the file was Exported in European format then select Semicolon Text Import Wizard Step 2 of 3 Treat consecutive delimiters as one Text qualifier B atts FEA1 BMS Voltage 11 00 26 451 2 4 16950E 7 44150E z 11 00 26 857 5 1 04010E 6 48040E z 11 00 26 9 76 E 4 76750E 7 44690E 2 4 Finally Press Next and Excel will ask you what data format each column should take Text Import Wizard Step
49. PH2 Voltage THD PH3 Voltage THD SUM 10002 E 4 0000 u 26500 m 45 500 m Watt PH1 RMS Voltage Po RMS Voltage P a ip RMS Voltage P 999 80 4 0000 u Time s n and Log View too Time Watts PHL PPAL RMS Voltage PHL PPAL RMS Voltage PHZ PPAL RMS Voltage 3 PPAL RMS VoltageSUMPPAL Voltage THD PHL Pr 1 095537 582 10000 kW 574 56b nV 25 602 mV 44 605 mV 48 249 mV 39487 m 2 55 38 287 10000 kW 7174 20 nV 25 554 mV 44577 mV 48 111 mV 39451 rn 3 0975538 681 10000 kW 788 82 nV 25 554 mV 44 505 mV 48193 mV 39451 m 4 031 10000 kW S9163 nV 25 508 mV 44 639 mV 48121 mV 35 423 m 5 0975539 481 10000 kW S59447 nV 25528 mV 44523 mV 48007 mV 33 386 m 6 555739 830 10000 kW 1 0885 uy 25 495 mV 44 508 mV 48010 mV 39 338 m 7 55 40 280 10000 kW LOL65 uW 25 526 mV 44 550 mV 48 003 mV 398373 m B 0555 40600 10000 kW 1 1603 uV 25 532 mV 44572 mV 47958 mV 39 354 m 8 55 41 081 10000 kW 1 2787 uW 25 562 mV 44419 mV 47923 mV 39 301 m 10 0655 41450 10000 kW 12519 uV 25 521 mV 44 303 mV 47952 mV 39259 m 11 55 41 E80 10000 kW L25307 uy 25487 mV 44 370 mV 47 951 mV 33 271 m 12 55 42 280 10000 kW L3703 uV 25459 mV 44 535 mV 47582 mV 39 325 m 13 55 42 680 10000 kW L3585 uW 25 468 mV 44 614 mV 47952 mV 39348 m 14 0555 43079 10000 kW 13337 uV 25472 mV 44754 mV 47949 mV 39392 m 15 u55 43 487 10000 kW L3287 uW 25 462 mV 44 545 mV 47940 mV 39316 m 4 n
50. a atanh a log2 a log a sine of a cosine of a tangent of a arcsine of a arccosine of a arctangent of a hyperbolic sine of a hyperbolic cosine of a hyperbolic tangent of a hyperbolic arcsine of a hyperbolic arccosine of a hyperbolic arctangent of a logarithm base 2 of a logarithm base 10 of a 63 PPA Datalogger Software User Manual In a exp a sqrt a sign a rint a abs a min a Z max a sum a Zz avg a Z natural logarithm base e of a e to the power of a the square root of a returns 1 if a is ve 1 if a is ve rounds a to the nearest integer gets the absolute value of a gets the smallest value in the list gets the highest value in the list gets the sum of all values in the list gets the mean average value of the list The following operators can be used for equations 1 a amp amp b 2 a b 4 a lt b 4 a gt b 4 al b 4 a b 4 a gt b 4 a lt b 5 at b 5 a b 6 a b 6 a b 7 a b 8 a logical AND logical OR less than or equal greater than or equal not equal equal greater than less than addition subtraction multiplication division a to the power b parenthesis Where the parenthesised value is the priority they execute in the higher the priority the earlier they re executed Name Watts
51. age PH2 Mechanical Power RMS Voltage PH3 Voltage THD RMS Voltage SUM Curent HD A A F Voltage THD PH1 Voltage THD PH2 Ta Series Voltage THD PH3 Voltage THD SUM You can add or remove parameters from this list or press the OK button in the bottom right corner to commence with listed selections 2 PPA Datalogger Software User Manual 6 8 Manual Log Mode Manual Log Mode is one of Measure Mode s 5 measurement settings that allows the PPA Datalogger software to read measurements from the connected Instruments at one rate and record the same data at another rate Manual Log Mode allows the user to add notes to each appended result however it disables the option to use Graph View Settings View Control 9 Software Interval 1 s y Auto Append MULTILOG REAL TIME LOG START CLEAR LOG 30 sects Freeze Display ZERO PPA1 RESULTS Frequency PH1 Watts PH1 RMS Voltage PH1 RMS Voltage PH2 Log real time table Scheduled testing Direct log to CSV RMS Voltage PH3 RMS Voltage SUM Voltage THD PH1 Voltage THD PH2 Voltage THD PH3 Voltage THD SUM High Speed Mode Enter Highspeed Mode Auto Append allows the software to read data and log data at different rates The data is read at the interval speed and logged at the append speed Log direct to CSV allows the appended data to be added directly to a
52. asuring at a speed of 100ms or lower PPA Datalogger will suggest you enter High speed Mode however High speed Mode can be entered or exited manually by pressing the button in the bottom right corner of the Measurement Window Instrument Interval is required for High speed Mode so it is recommended that the Instrument that will be logging in High Speed Mode will need its Speed and Window settings setup appropriately 6 4 The Multilog Window After setting the log speed the next step to setting up a measurement is choosing what to measure While using Scheduled Testing mode there is no need to use this button to set a Multilog To open the Multilog Window and choose the parameters each instrument will measure press the Multilog button found on the left side of the screen above the Measure Results Window MULTILOG REAL r This button is only available if you are connected to at least one Instrument and your Measurement Log is cleared 23 PPA Datalogger Software User Manual STORE RECORD SELECTION SUM NEU SUM NEU Selected Items eee ee TERES Function Channel Mechanical Speed rpm Torque Mechanical Power 313 E31 ES ESSI 004 OG maaa Add ADI Input ADI Output Function OO E ES ESI ESI alaja ESI ES E ES ESILESI 0000008800800 3 OO Es ES ESI ESI EST ESI EST EST 0000 0020202024020 EST ESI EE0E00020200020202020202020004 2 HEHE PHL sl x m E sl sl
53. by changing which phases are displayed and which colour represents each phase Hone Phasel Phase 2 Phase 3 Neutral w Another way the harmonics graph can be customized is by changing what information shows up on the oraph tooltip T 10096 Ph 2 Pho 7 Phi Neu 0 0000 V IEEE Current 0 0000 V al 00005 Volt 10096 HO HO L 0 0000 V Cur 1009 And finally the graph can be customised by showing either Voltage only Current Only Both as well as scaling each graph PPA1 Harmonics han je 30m 20mA 30mA 30mA Phases l Ensure that the Harmonic Analyzer configuration parameters are set up according to the type of test to be undertaken 43 7 2 PPA Datalogger Software User Manual Reading Harmonics Data Once Harmonics Mode has button will begin to read the associated Harmonics data Frequency LOO kHz 20000 kHz 3 4000 kHz 40000 kHz 50000 kHz 6 0000 kHz TXXXX kHz E0000 kHz 10000 kHz 10 000 kHz ILODO kHz 12000 kHz 13 000 kHz 14 000 kHz 15 000 kHz PHI V 255 50 ul T2251 uW 145 79 uV 70372 uV 46707 uV T8 549 uW 136 49 uv 235 48 ul 14087 uV E3537 uV 129 60 ul 49495 uV 127381 uW 52103 uV 21737 uW A 103850 uA 13812 uA 51181 uA 12517 uA 19977 uA 5 8875 uA ZT B2B uA 11614 uA 4 7404 uA 427711 uA amp 5341 uA 9 1961 uA 50143 uA 12705 uA PH V 195390 uW 28041 uV EI 540 uv 70 551 uV B5 294 ul 30717 uW SO 650 uV
54. display all available PPA measurements side by side PPA1 RESULTS Frequency PH1 Watts PH1 RMS Voltage PH1 RMS Voltage PH2 RMS Voltage PH3 RMS Voltage SUM Voltage THD PH1 Voltage THD PH2 Voltage THD PH3 Voltage THD SUM To revert back to any individual PPA s real time display click on the View Full on the appropriate PPA RESULTS ven tat PPA2 RESULTS mm Frequency PH1 Watts PH1 RMS Voltage PH1 RMS Voltage PH2 Freq uency PH1 Watts PH1 VA PH1 eee AREER _ VAPH VAPHS PPA3 RESULTS Wes Fui PPAd RESULTS are a Frequen cy PH1 Watts PH1 VA PH1 Frequency PHI Watts PH1 uf Peak Voltage PHI uf Peak Voltage PH RMS Voltage PH1 RMS Voltage PH2 RMS Voltage PH3 144 40mV 14354mv RMS Current PH1 RMS Current PH2 RMS Current PH3 W mia 36 PPA Datalogger Software User Manual 6 15 Exporting Data to CSV Export to CSV once the test has been stopped press the Export button in the bottom right corner of the Measure Window Export And select Export to CSV Export to 0 Export to Excel Settings File Location File Location Select file for CSV logging jk Computer Windows7_OS C PPA Datalogger Log Files Organize v New folder k pending releases Name Date modified Type J Utilities L Scheduled Test 02 10 2015 12h 12m 0 02 10 2015 12 15 Text Document k Product Manuals Lj Scheduled Test 02 10 2015 12h 3
55. ds of logging data A few simple steps will see PPA Datalogger ready to record up to 60 of the PPAs wide range of multilog parameters on up to 4 PPAs synchronised by PPA Datalogger with speeds up to 200 results a second Measure mode is a truly flexible measuring system which will fulfil most needs 6 2 Measurement Speed The first step to setting up a measurement is to set the measurement speed While using Scheduled Testing mode there is no need to set the measurement speed here There are 2 speed setting modes to choose from Software Interval and Instrument Interval Software Interval s Instrument Freeze Display ZERO Software Interval is independent of the Instrument and its measurement cycle and requests results from the Instrument at the interval set in the Interval box from 0 001s upwards Instrument Interval requests data from the Instrument at the same speed that the instrument calculates it The speed the Instrument measures at can be controlled using the Speed setting in Acquisition using the Configuration Control Panel Configuration Acquisition Contral Winng 3 phase 3 wattmeter 21 PPA Datalogger Software User Manual The Freeze Display button shows if the PPA s front screen will be paused during measurement allowing the Instrument to concentrate on its calculations This can be set manually however PPA Datalogger will automatically set the screen to be frozen when logging at speeds under
56. e Settings Display Measure Harmonics S s J s J After navigating to and selecting the CSV file to re load press Open k k Computer k Windows7_OS C PPA Datalogger Log Files Organize New folder k Andrew Tyler p Name standards k pending releases Utilities k Product Manuals Lj aircraft direct to csv txt _ Export CSV bit j harmonics direct to csv txt interharmonics direct to csv txt H Scheduled Test 02 10 2015 12h 12m 0 Libraries Lj Scheduled Test 02 10 2015 12h 30m ES Documents a Music Pictures 53 Subversion BE Videos Ls Computer Windows7 OS C r DVD Drive D 15 0 4420 a W fk K ar File name Export CSV txt Date modified 06 10 2015 09 05 05 10 2015 10 18 05 10 2015 15 28 06 10 2015 08 48 02 10 2015 12 15 02 10 2015 13 30 Search PPA Datalogger Log Fil Type Text Document Text Document Text Document Text Document Text Document Text Document 864 KB 265 KB 63 612 KB 864 KB 21 KB 305 KB 67 PPA Datalogger Software User Manual PPA Datalogger will then be in Measure Mode displaying the last result in Real Time View PPA1 RESULTS Watts PH1 RMS Voltage PH1 RMS Voltage PH2 RMS Voltage PH3 RMS Voltage SUM Voltage THD PH1 Voltage THD
57. e scope waveform Continuous reads new waveforms from the PPA periodically Voltage Range IV Current Range 30mA Coupling ac dc Bandwidth Wide Voltage Current 52 PPA Datalogger Software User Manual 9 Capture Mode 9 1 Downloading a screenshot from To switch the PPA Datalogger and the connected instruments to Capture Mode press the Capture menu item at the top of PPA Datalogger a PPA Data Logger V3 2b PPA USB PPA5530 165 00768 2 125 Configure Display Measure Harmonics Scope CONTROL PPAZ PPAS CONTROL PPAL Configuration Acque This puts PPA Datalogger into Capture Mode PPA1 Screen Capture To download a screenshot from the PPA display screen press either Black and White Download or Colour Download 23 PPA Datalogger Software User Manual PPA Datalogger will show the download within a Progress Window Download Downloading Screenshot T complete Once the download is complete the screenshot from the PPA will be placed on the Canvas PPA1 Screen Capture Now the screenshot can be copied to Clipboard for pasting into emails image editors or anywhere else using Save to Clipboard 54 PPA Datalogger Software User Manual Saved as a bitma
58. ettings can be modified in the Configuration Control Panel he menus in PPA Datalogger are designed to mimic the Instrument s settings panels For more information on what each setting does check the respective Instrument s User Manual Finally the changes you made need to be communicated to the Instrument any amended settings are sent by pressing the SET UP PPA button The changes must be sent to the instrument for the instrument to be configured correctly Additionally you can hide and show the Configuration Panel by pressing the Hide Settings and Show Settings button 13 PPA Datalogger Software User Manual 4 2 Saving Configurations Click Configure and hover over the Saved Config term in the dropdown menu To save the current configuration from the Configuration Panel highlight Save and click on one of the 10 save slots Configure Display Measure Harmonics Scope Capture Connection Topas m waw Saved Contig Open CSV File Settings Add Edit Equations x The software will then ask for name to save the configuration as Once a name has been entered press OK and the software will save this configuration Load d Eu Care mrt A configuration can be overwritten by clicking on an already saved config and saving the new settings 14 PPA Datalogger Software User Manual 4 3 Loading Configurations Click Configure and hover over
59. ighlight default settings and press the Enter Key Then in the software press READ PPA to read those settings into PPA Datalogger From here the settings can be modified in PPA Datalogger s Configuration panel such as frequency step and step count but any changes made must be sent to the PPA before commencing Waiting for Results Pressing START begins the Aircraft TVF105 sweep bringing up a Progress Window letting you know that PPA Datalogger is waiting on the PPA to complete its calculations Downloading Results Estimated time remaining 16 Seconds When the sweep is complete PPA Datalogger will begin downloading the results A message will appear when the sweep download is complete Harmonics Results have been downloaded 48 PPA Datalogger Software User Manual The results will not be shown within the software but can be exported to Excel If the Log to CSV parameter was ticked prior to the sweep then the CSV file will contain all sweep data for all Harmonics previously set File Edit Format View Help Harmonic Frequency Inter Harmonic Voltage Inter Harmonic Current Inter Harmonic Voltage Ph2 Inter Harmonic Current Ph2 Inter Harmonic Voltage Ph3 Inter Harmonic Current Ph3 1 2 00000000E 001 5 25193289E 004 1 59637304E 004 6 38532452E 004 1 38497679E 004 3 66166234E 004 2 32269289E 004 2 4 00000000E 001 9 49001 405E 005 8 14289087E 005 1 39586395E 004 1 33123947E 004 3 88925429E 00
60. ion ADI Output Function Output selected nems ADT Ins 2 Function Channel Frequency PH1 Watts VA PH1 RMS Voltage PH1 ADI In3 ADI Add ADI Output Remove Press OK to confirm your multilog selection 59 PPA Datalogger Software User Manual If you selected your ADI Output to be displayed as a multilog parameter it should now be in the Real Time view PPA1 RESULTS Frequency PH1 Watts PH1 VA PH1 RMS Voltage PH1 Air Pressure To Motor When you start the multilog running the ADI parameters will be setup inside the instrument and the Output Voltage will be sent out of the chose channel 60 PPA Datalogger Software User Manual 11 Equations in PPA Datalogger 11 1 Using Equations To use equations in PPA Datalogger the exe file must be accompanied by muParser dll Equations mode in PPA Datalogger is a way of using Measure Mode s Multilog Parameters to create custom equations Equations can be added to Multilog Setups and logged alongside other Multilog Parameters as well as exported 11 2 Equation Editor Window To see the Equation Editor Window click Configure and then select Add Edit Equations Configure Display Measure Har Saved Config Connection k Open CSV File Add Edit Equations This brings up the Equation Editor Window Equation Editor Load Equation Equation Variables Variable Function Channel Instrument ElapsedTime ElapsedTi
61. le name and location Select file for CSV logging CS Computer Windows7 OS C PPA Datalogger Log Files Organize v New folder di pending releases a I Date modified Utilities J No items match your search ow Libraries Documents Music k Pictures Subversion B Videos jM Computer L Windows OS C f DVD Drive D 15 0 442 File name measurement 1 txt Save as type Hide Folders Cancel Once the name and location are set press Save and return to the data logging screen 34 PPA Datalogger Software User Manual To start the test press the START button and PPA Datalogger will read data from all connected instruments Each line of data is displayed in Real Time view and simultaneously added to the CSV file set earlier Each time a result comes in the Elapsed Log Time will update ET em ee Elapsed Log Time ULTILOG REAL TIME GRAF LOG so CLEAR LOG sitam EET 00 00 10 PPA1 RESULTS maa Frequency PH1 Watts PH1 RMS Voltage PH1 RMS Voltage PH2 ne RMS Voltage PH3 RMS Voltage SUM Voltage THD PH1 Voltage THD PH2 A Voltage THD PH3 Voltage THD SUM was High Speed Mode Pressing the STOP button will end the log The CSV file can then be changed to start a new test or pressing START again without changing the file will add more data to the original CSV file a vh measurement 1 txt Notepad
62. low you to set the number format for those CSVs between Standard Decimal and European decimal Log Comms allows you to set the software into Debug mode PPA Datalogger Software User Manual 3 Connecting 3 1 Preparing the PPA Before the software can connect the PPA must be ready to accept the connection To prepare your PPA for connection with PPA Datalogger ensure the unit is powered on and the cables are connected Next you must ensure the Instrument is correctly set up to reflect the type of connection you are using To do this access the REMOTE menu on the unit navigate to the Interface option and select the interface you are using to connect to the software RS232 USB or LAN If you select RS232 you will need to additionally set the Baud Rate of the cable you intend to use And for LAN you ll need to set an IP Address for the Instrument PPA Datalogger Software User Manual 3 2 Connecting to your PPA To begin connecting to an instrument click on Configure and select Connection from the dropdown menu WO PPA Data Logger V3 2b Configure Display Measure Harmonics Scope Capture Connection Saved Config Open CSV File Configuration Acq Settings Add Edit Equations This brings up the communications window where you ll set up how many instruments you want to connect to and how Communications 23 Phase i 29 Phase 12 Phase
63. me Add variables to list Add variable to eqn Save Cancel 61 PPA Datalogger Software User Manual 11 3 Selecting Variables To add Variables from the Multilog Window for use in equations click the Multilog button in the bottom left corner of the Equation Editor Window Add variables to list This brings up the Multilog Window From here select any Multilog Parameters to add to the variable list and then press OK Selected Items Function Channel Watts Watts PHZ The selected Multilog Parameters are now added to the Variables list in the Equation Editor Window Variables Variable Function Channel Instrument ElapsedTime ElapsedTime M A N A WattsPH1PPA1 Watts PH1 PPA1 WattsPH2PPA1 Watts PH2 PPAL 62 PPA Datalogger Software User Manual 11 4 Writing Equations Once the Variables for the equation have been selected the next step is to write the equation To add one of the selected variables to the equation either double click it in the variables list or select it and press the Add variable to eqn button Equation WattsPH1PPAL Variables Variable ElapsedTime WattsPH1PPAI WattsPH2PPA1 Add variables to list Function Channel Instrument ElapsedTime M A M A Watts PHI PPA1 Watts PH2 PPAL Add variable to eqn The following functions can be used for equations sin a cos a tan a asin a acos a atan a sinh a cosh a tanh a asinh a acosh
64. me End Time Interval 12 00 00 02 10 7015 12 10 00 02 10 2015 1 000 12 12 00 02 10 2015 12 15 00 02 10 2015 Very Fast 12 30 00 02 10 2015 13 30 00 02 10 2015 Window 0 010 Start Time End Time Interval 12 12 00 02 10 2015 12 15 00 02 10 2015 Very Fast 12 30 00 02 10 2015 13 30 00 02 10 2015 Window 0 010 Once all tests have been added to the schedule press the Start button in the bottom right corner and the Schedule Progress Window will appear counting down the time until the next test Starts Running in Schedule mode There are 2 tests left on the schedule Time til next test 6 Minutes 34 Seconds 12 112 0 2nd October 2015 Start Now The Schedule Progress Window tells you how many tests are left and when the next test will begin 32 PPA Datalogger Software User Manual When the next scheduled test is due to be begin the Schedule Progress Window will automatically disappear and start testing however pressing the Start Now button starts the next test immediately instead of waiting for the start time Settings View Control Software REAL TIME GRAPH LOG STOP CLEAR LOG Instrument psed Lag Freeze Display ZERO 00 00 04 Data Settings PPA1 si RESU LIS Manual lag Frequency PH1 Watts PH1 VA PH1 nid IELE Direct log to CSW Overwite C5V VAr PH1 Power Factor PH1 While the test is running you can press the Stop button to stop the test immediately Alternatively when the Skip b
65. o CSV Mode 34 6 12 Overwrite CSV MOQ crases aperin dde picem 36 6 13 Customizing Graph 38 6 14 Logging with multiple Instruments 39 6 15 Exporting Data tO CSV u uuu uu p as Quies Xa tec rid 40 6 16 Exporting Data to Excel 41 7 Harmonics u 42 7 1 Setting up in Harmonics Mode 42 7 2 Reading Harmonics Data u u nn 44 7 3 nterharmonics 86 46 7 4 Aircraft TVF105 6 48 7 5 Exporting Harmonics to Excel 50 8 Scope MOUG uuu sut S S us 51 S USING ScopeM0o0e Luu uu uu ket araa 51 9 Capture MOUG uuu A ERRWxEERSaNEEENEEBAEESKS RU EERERRSEU IEEE 53 9 1 Downloading a screenshot from a PPA 53 10 Using an ADI with PPA Datalogger 56 ado Em 56 10 2 Adding ADI 5 56 10 3 Adding an ADI Output 58 11 Equations in PPA Datalogger 61 TEL USG u n acetic ablatum vs dica Eus au 61 11 2 Equation
66. p image using Save to Bitmap m Save to Bitmap QC k Libraries k Pictures k hd t Es Organize New folder n pending releases Utilities k Product Manuals Pictures library Arrange by Folder Includes 2 locations x Narne Date Size Rating a oy Libraries a k nda 10 06 2015 12 39 Es Documents Ji GIFs 19 03 2014 17 01 a Music k MAL 24 10 2013 09 50 i Pictures Dell Image Expert Images 30 08 2013 14 24 Subversion Ji DEP 06 08 2013 10 06 B Videos Ji IEC Screenshots 02 05 2013 08 36 k Icr repeating 24 04 2013 17 05 Computer Ji NVIDIA Corporation 16 04 2013 13 24 Windows _O5 C k Piezo_guide 12 04 2013 14 12 DVD Drive D 15 0 442C Ronestinea mide m ma Dn 212 523 F M L 4 i File name pi screenshotlbmp Save as type a Hide Folders F Or exported to a blank word document using Save to Word im 3 r Em Microsoft Word Wes PY Ae a faa E Past 3 Copy tU aste jp Format Painter Aa h S SRE a i Clipboard s Font a Paragraph E AaBbCcDc AaBbCcDc AaBbCi T Normal TNoSpaci Heading 1 55 PPA Datalogger Software User Manual 10 Using an ADI with PPA Datalogger Only available with the PPA45 55xx Instruments 10 1 Setup Using the Configuration panel in the software navigate to the Auxiliary Control menu using the AUX button From here set your
67. pport for more details Once registered and your account has been activated you will have access to the software downloads section 2 2 Installation Wherever possible at N4L we try to develop software that enables the engineer to be ready and performing tests as soon as possible With this in mind we have made PPA Datalogger s installation method as simple as possible To install PPA Datalogger simply download the exe file onto your PC s hard drive or an external drive such as a USB memory stick and run it straight away 2 3 Optional installation Equations Additional to the exe you will find a file called muparser dll This file provides additional functionality to PPA Datalogger when kept in the same location as the exe file granting access to the Equations mode 2 4 PPA Datalogger Software User Manual Software Settings To access the Settings window go to Configure and click Settings from the dropdown menu PPA Data Logger V3 2b Configure Display Measure Harmonics Scope Capture Connection Saved Contig P Open CSV File Settings Add Edit Equations From here you can change some of the settings in PPA Datalogger Log Date lets you add the date as well as the time to Measure mode s table and export options Remember CSV File makes the software remember the location and filename of the last CSV file you exported CSV File Format and Harmonic CSV mode al
68. r Multilog Parameters press OK and you ll see the ADI parameter from earlier in the real time view PPA1 RESULTS Frequency PH1 Watts PH1 VA PH1 RMS Voltage PH1 Air Pressure 57 PPA Datalogger Software User Manual 10 3 Adding an ADI Output To add an ADI Output go to the Multilog window and select one of your Multilog parameters to use as a reference for the output Selected Items Function Channel Frequency Watts PH1 VA PH1 ADT Ins ADB Then press the ADI Output button below the ADI Output list ADI Output Function Remove Add ADI Output 58 PPA Datalogger Software User Manual This will bring up the ADI Output window the name of the Mutlilog parameter that is selected to be the reference is displayed in the window for easy reference You ll want to select which output channel you want the output to be sent to red and set any necessary scale factor and zero offset green Tick the Display as Multilog Box if you want PPA Datalogger to Display the expected output voltage as a multilog parameter ADI Output en F Name To Motor optional Multilo q Zero offset 0 000 Sample Input 5 000 Expected Output 5 0000V V Display as multilog Cancel Or O e Pressing OK brings you back to the multilog window Your Output will be added to the ADI Output selection and if you selected to display your ADI Output as a multilog it will be in the Multilog select
69. strument Freeze Disola EF reeze Display ZERC REAL TIME GRAPH LOG STOP 00 00 11 nm n 1 gt Data Settings Time Frequency PH1 PPA1 Watts PH1 PPAL RMS Voltage PPAL RMS Voltage PH2PPAl RMS Voltage PH3 PPAL RMS Voltage SUM PPAL vue 1 09 24 34 958 50 000 Hz 14337 uW 26 691 mV 45192 mV 47 678 mV 39 853 mV 2 092435 958 50 000 Hz 16421 uW 26579 mV 45 226 mV 47 663 mV 39822 mV 3 09 24 36 958 50 000 Hz 16598 uW 26 326 mV 45 235 mV 47 661 mV 39 741 mV 4 09 24 37 961 50 000 Hz 12290 uW 26323 mV 45119 mV 47 614 mV 39 685 mV 5 09 24 38 958 50 000 Hz 15893 uW 26534 mV 45133 mV 47 635 mV 39767 mV 6 09 24 39 958 50 000 Hz 20802 uW 26 608 mV 45141 mV 47 667 mV 39 805 mV 7 0924403958 50 000 Hz 16307 uW 26 328 mV 45 289 mV 47 649 mV 39 755 mV 8 092441 962 50 000 Hz 19194 uW 26357 mV 45 262 mV 47 642 mV 39754 mV 9 09 24 42 958 50 000 Hz 897 09 nW 26 400 mV 45 207 mV 47 687 mV 39 765 mV 10 0924439357 50 000 Hz 14290 uW 26337 mV 45177 mV 47 675 mV 39 750 mV Export 11 08 2444958 50 000 Hz 12593 uW 26 593 mV 45193 mV 47 688 mV 39828 mV 12 05 24 45 961 50 000 Hz 13491 uW 26445 mV 45135 mV 47 691 mV 39757 mV High Speed Mode To stop recording press the STOP button With the recording stopped the logging can begin again by pressing START or the data can be cleared with the CLEAR LOG button 30 PPA Datalogger Software User Manual 6 10 Scheduled Testing Mode Scheduled Testing Mode is one of PPA Dataloggers 5 meas
70. ting to your PPA 10 4 Configuration Panel erre een nnn 13 4 1 Using the Configuration Panel 13 4 2 Saving Configurations essssssee nns 14 4 3 Loading Configurations een 15 4 4 Exporting Configurations 16 4 5 Importing ConfigurationsS 1 5 The Display Menu 5x saa irn RC RR cR RR 18 5 1 Using the Display Menu 18 Dez SIVE O BIPM IPIE EDO ETE UR IPEA 19 59 3 COBY tO CIIDDOG 20 9 EXPONE WOO nepotum o ba Pee osa 20 6 Measure MIO Ge uuu u M 21 6 1 Introduction to Measure Mode 21 6 2 Measurement Speed 21 digrnispeed ModE ba toe rrt steal e b DE eio 22 6 4 The Multilog Window enne 23 6 5 Selecting Parameters r 25 6 6 Saving a Multilog Selection 26 6 7 Loading a Multilog Selection 27 PPA Datalogger Software User Manual 6 0 Manual Log MOC unu Pw Cea 28 6 9 Log Real Time MOde DA ERE ER ERES 30 6 10 Scheduled Testing Mode 31 6 11 Direct Log t
71. ts have been exported Excel will open automatically showing all results separated into columns The following is an example of an Aircraft TVF105 sweep exported to Excel 50 PPA Datalogger Software User Manual 8 Scope Mode 9 1 Using Scope Mode Not available with the series To switch the PPA Datalogger and the connected instruments to Oscilloscope Mode press the Scope menu item at the top of PPA Datalogger Configure Display Measure 3 Capture CONTROL PPA PPA PPA3 PPA4 CONTROL PPAT Conhfiguratianc Acquis ACQU COUPLING RANGE This will put PPA Datalogger into Scope Mode PPA1 Oscilloscope Voltage Range 300mV Current Range 30mA Coupling ac dc Bandwidth Wide Current 0 0000 s div The scope display can be edited to show which phases are displayed and which colour represents each phase Hone Phase 2 Phase i Neutral Neutral w 51 PPA Datalogger Software User Manual The Scope display can be further customised to show or PPA1 Oscilloscope Voltage Range 300mV Current Range 30mA Coupling ac dc Bandwidth Wide Phase 2 F Voltage Both Current Single Continuous 0 0000 s div Once the scope has been set up press either Single or Continuous to download the scope image Single reads a singl
72. urement settings that sets up multiple Log Direct to CSV type measurements in a schedule each with their own Multilog setup and Speed setting me View Control CE Setting ne Software REAL TIME LOG CLEAR LOG Instrument a TE Freeze Disp ay ZERO 00 00 00 Data Settings PPA1 RESULTS Manual log Log real time table 7 Direct log to CSV Overwrite CSV Select File NN Export NL NN High Speed Mode In the Scheduler Window click the white Output Directory Box set a folder for the CSV files with 02 10 2015 the results of the scheduled tests to go into Then start a Start Time and Date and an End Time and Date for this test to run between Next set a Measurement Speed to test at Set a Multilog Setup by pressing the multilog button Finally once those 3 steps are complete click Add to add this test to the schedule 31 PPA Datalogger Software User Manual The test is then added to the Schecule List Repeat setting a start end time speed multilog setup and pressing the add button for each test to be added to the schedule Start Time End Time Interval 12 00 00 02 10 2015 12 10 00 02 10 2015 1 000 12 12 00 02 10 2015 12 15 00 02 10 2015 Very Fast 12 30 00 02 10 2015 13 30 00 02 10 2015 Window 1 110 To remove a test from the schedule select a test in the Schedule List then press the Remove button Remove Start Ti
73. utton is pressed the next test is Skipped and the Schedule Progress Window will show the due time for the next test in the schedule or if it was the last test in the schedule it will close the Schedule Progress Window down The Cancel Button will cancel all remaining scheduled tests and close down the Schedule Progress Window When each test is complete its CSV file will be in the directory set in the Scheduler Window E Name Date modified Type E Scheduled Test 202 10 2015 12h 12m 0 02 10 2015 12 15 Text Document Scheduled Test 202 10 2015 912h 30m 0 02 10 2015 13 30 Text Document 33 PPA Datalogger Software User Manual 6 11 Direct Log to CSV Mode Direct Log to CSV Mode is one of Measure Mode s 5 measurement settings that reads the data from all connected instruments and records that data straight to a CSV file Settings View Control uum 2 MULTILOG REAL TIME GRAPH LOG START LEAR LOG Instrument interval _ Elapsed Log Time Freeze Display ZERO 00 00 00 PPA1 RESULTS Bur Frequency PH1 Watts PH1 RMS Voltage PH1 RMS Voltage PH2 RMS Voltage PH3 RMS Voltage SUM Voltage THD PH1 Voltage THD PH2 T sasa Fe Voltage THD PH3 Voltage THD SUM EE e High Speed Mode Enter Highspeed Mode The first thing to do when logging direct to CSV is to set the file to log to by clicking in the white CSV File box bringing up a window to set the fi