Home

ATLAS 800 Series Quad T1-PRI Module User Manual

image

Contents

1. 3 7 ja EE 3 7 PON a ea ea EE DR entl 3 7 LES Geib 3 7 Performance JSM uini eese n hee p e iii e Aere con e Eee Dor 3 7 Performance 24hr iras 3 7 Gontfiguration sisses req e p tle iet tem ee ente deque reque eda ae ie ee tee teet 3 7 M BP ERE 3 7 Port Namen oim EU E ER e es HE ed E e bis ts 3 7 Frame eie be ERO ERR ae es RS 3 7 cR 3 7 Tx Xel ise idein et tenue nominee palate aia oiii 3 7 TXPRM 4 2 4 Basta set t On Bas Al hbo dusted Hat lis 3 7 EBQ isst db gs 3 8 EB Aeccept ue EN AA me qne m oto neue NDS 3 8 P lse Density 35 co menthe A ar C HT HUE QUEUE III Renee 3 8 Mc H 3 8 O ato e qoe bii be d Eu 3 8 Loe LB iii UA SG RON n OS AT OE BR 3 8 MO LEE 3 8 juo P 3 8 Remote LB 1 2 O 3 9 ANSI FDL Liht xi ads 3 9 ANSLIEBDE Pyld 22 25 5 2222222222 naaa 3 9 AT amp T bandido EE A EE CA 3 9 Pattern 3 sebo eoe e b ee Re OP IR elite e bist eR as dix 3 9 ATOM A UTI TN 3 9 AN Zeros rei ie e etim eiiis ere ica ae UR RE EU OU acts 3 9 ORSS ee Best vete ad 3 9 ORSSZRLEB Results anioi anne eR Ob RE ERE TIGER e E eee PIONEER CREARE c qM 3 9 al MM ER e see RT ec 3 9 TAA toe E E EE E T na E EE ae atiende ta p ee bee de Dres eta 3 9 ATLAS Features Used with Quad T1 PRI Module esses enne enne nnnen 3 10
2. The Quad T1 PRI Module design includes a label above each RJ 48C con nector identifying the port on the card Each port comes with an RJ 48C con nector for the T1 circuit interface and a single Bantam plug for monitoring received data 61200185L3 1 Quad T1 PRI Module User Manual 1 3 Chapter 1 Introduction 1 4 Quad T1 PRI Module User Manual 61200185L3 1 Chapter 2 Installation BEFORE INSTALLING THE QUAD T1 PRI MODULE Carefully unpack and inspect the Quad T1 PRI Module for shipping dam ages If you suspect damage occurred during shipping file a claim immedi ately with the carrier and then contact ADTRAN Technical Support see the last page of this manual for pertinent information If possible keep the orig inal shipping container for returning the Quad T1 PRI Module for repair or for verification of shipping damage Shipping Contents The ADTRAN shipment includes the following items Quad T1 PRI Module Quad T1 PRI Module User Manual insert into the ATLAS User Manual Four cables RJ 48C to RJ 48C ADTRAN P N 3125M008 Two crossover cables RJ 48C to RJ 48C ADTRAN P N 3125M010 Two RJ 48 to DB 15 adapters INSTALLING THE QUAD T1 PRI MODULE Figure 2 1 on page 2 2 represents the action required to properly install the Quad T1 PRI Module as described in the Step Action table on page 2 2 61200185L3 1 Quad T1 PRI Module User Manual 2 1 Chapter 2 Installat
3. 5 Indicates the module status Displays the part number of the module read only Displays the serial number of the module read only Indicates whether the clock is locked to its specific source Displays the PCB revision read only Read security 5 Displays the current T1 alarm status Indicates the port number Read security 5 Displays an alarm condition on the ATLAS unit Press ENTER to access this menu item LOS Loss of signal Indicates no signal detected on port interface RED Indicates inability to frame data received on the port Alternately referred to as Out of Frame OOF YELLOW Receiving remote alarm RAI on port BLUE Receiving unframed all ones from the port Alarm Indicator Signal AIS DSO ALARM Displays per DS0 alarm status These alarms usually indicate the failure to receive the protocol that has been configured for the DSO Indicates the strength of the signal in dB received on the port 61200185L3 1 Quad T1 PRI Module User Manual 3 5 Chapter 3 Operation DSO STATUS DSO ALARMS SIG STATUS PERFORMANCE CURRENT PRT CLR ES BES SES SEFS LOFC CSS Read security 5 The DSO status indicates usage on a DSO basis for each port These options are read only nactive Active call on this DS0 Active D Channel DS0 Maintenance DSO Dedicated DSO Off hook Detected JJ O Z Sur Ringing Detected Read security 5 Displays per DSO alarm statu
4. Factory Restore istentldouu een iat aeree du imn cbe d A Re EE d ER add a ER iia 3 10 x Quad T1 PRI Module User Manual 61200185L3 1 Table of Contents R n Self TEST E EE U U 3 10 Mapping italia a bc Niels aaa a Aa 3 10 Appendix A Dial Plan Interface Configuration essessessessessessesscoecesessesscoseesessesneoseosessesnconcesessesseoseeseeses A 1 O NN Index 1 61200185L3 1 Quad T1 PRI Module User Manual xi Table of Contents xii Quad T1 PRI Module User Manual 61200185L3 1 List of Figures Figure 1 1 T1 Bandwidth Management Application sess eee 1 1 Figure 1 2 Quad Fl PRI Module n etie hono ne tr 1 3 Figure 2 1 Installing the Quad T1 PRI Module see eee ee nennen 2 2 Figure 3 1 Modules Menu Ie te eu etel stetit en atienden e et Hte 3 2 Figure 3 2 Menu Tree for Quad T1 PRI Modules Menu sess eene 3 2 Figure 3 3 Quad T1 PRI Menu Options esee eene enn 3 4 Figure 3 4 Network Loopback T staii sisisi eee e ir a tenen 3 9 Figure A 1 Dial Plan Menus ainda boton dodo A 1 61200185L3 1 Quad T1 PRI Module User Manual xiii List of Figures xiv Quad T1 PRI Module User Manual 61200185L3 1 List of Tables Table 2 1 Network Connection Pinout 61200185L3 1 Quad T1 PRI Module User Manual XV List of Tables xvi Quad T1 PRI Module User Manual 61200185L3 1 Chapter 1 Introduction QUAD T1 PR
5. 35 V 35 Figure 1 1 T1 Bandwidth Management Application gt lt m e pe Remote TI FTI Locations 61200185L3 1 Quad T1 PRI Module User Manual 1 1 Chapter 1 Introduction NEBS COMPLIANCE The ATLAS Quad T1 PRI Module P N 1200185L3 complies with the NEBS Network Equipment Building System Level III specification for GR 1089 CORE and GR 63 CORE This means that the ATLAS Quad T1 PRI Module will perform normally under certain electrical and physical stresses without posing a safety hazard to its users This module can be used in either the ATLAS 800 or the ATLAS 8007 5 However when applications require NEBS compliance this module should be used in the ATLAS 810PLUS a NEBS compliant version of the ATLAS 800PLUS FUNCTIONAL DESCRIPTION The Quad T1 PRI Module installs into any available option slot in the ATLAS chassis You can view the status of the module itself as well as the circuits to which it interfaces from the ATLAS front panel Additional status information is available via the terminal menu accessible through either a VT 100 terminal connected to the ATLAS Base Unit s control port or through a Telnet session established through the Base Unit s Ethernet port Use the terminal menu to configure the Quad T1 PRI Module and to download application software Features Features of the Quad T1 PRI Module are listed here e Four T1 interfaces e Each interface configurable for DS 1 DSX 1 o
6. 6 IFCE CONFIG USER TERM RBS A 7 CALLER ID NUMBER A 9 DID A 8 DID DIGITS TRANSFERRED A 8 DSOs AVAILABLE A 8 First DSO A 7 NUMBER OF DSOs A 7 SIGNALING METHOD A 8 installing the module 2 1 mapping 3 10 MODULES menus and submenus 3 2 ALARM 3 3 MENU 3 3 See also MODULES MENU REV 3 4 SLT 3 3 STATE 3 3 STATUS 3 4 TEST 3 3 TYPE 3 3 MODULES MENU 3 4 ALARM STATUS 3 5 ALARMS 3 5 BES 3 6 BLUE ALARM 3 5 BOARD REVISION 3 5 CLR 3 6 3 9 CODE 3 7 CONFIGURATION 3 7 Css 3 6 DSO ALARM 3 5 DSO ALARMS 3 6 DSO STATUS 3 6 Es 3 6 FRAME 3 7 INFO 3 5 INJ 3 9 LB ACCEPT 3 8 LBo 3 8 Lcv 3 7 LES 3 7 61200185L3 1 Quad T1 PRI Module User Manual Index 1 Index N O operating the module 3 1 Loc LB 3 8 Lorc 3 6 Los 3 5 PART NUMBER 3 5 PATTERN 3 9 Pcv 3 7 PERFORMANCE 15 MIN 3 7 PERFORMANCE 24 HOURS 3 7 PERFORMANCE CURRENT 3 6 PLL STATUS 3 5 PORT NAME 3 7 PRT ALARM STATUS 3 5 PRT CONFIGURATION 3 7 PRT PERFORMANCE CURRENT 3 6 PRT TEST 3 8 PULSE DENSITY 3 8 Onss RLB RESULTS 3 9 RED ALARM 3 5 REMOTE LB 3 9 Rx LEVEL 3 5 SEFS 3 6 SERIAL NUMBER 3 5 SES 3 6 SIG STATUS 3 6 TEST 3 8 TX PRM 3 7 TX YEL 3 7 UAS 3 7 YELLOW ALARM 3 5 NEBS compliance 1 2 P performance current 3 6 pinout 2 3 R RMA requests vii Run Self Test 3 10 S service vii 2 3 shippment contents of 2 1 specifications 1 3 capacity 1 3 connectors 1 3 framing 1 3 l
7. Quad T1 PRI Module User Manual 61200185L3 1 Chapter 3 Operation REMOTE LB PATTERN QRSS RLB RESULTS CLR INJ Quad T1 PRI Payload Loopback Line Loopback Figure 3 4 Network Loopback Test Write security 4 Read security 5 Sends loopback code to Remote CSU The following options are available ANSI FDL Line Requires ESF mode ANSI FDL PYLD Requires ESF mode AT amp T INBAND LINE Works in ESF and D4 mode Write security 4 Read security 5 Test pattern to be transmitted out the port The following options are avail able ALL ONES Framed ones ALL ZEROS Framed zeros QRSS Pseudo random pattern with suppression of excess zeros Write security 4 Read security 5 Indicates sync and errors of received data pattern Test Pattern and Remote Loopback Results Write security 4 Read security 5 Clears error counters on test pattern results menu Write security 4 Read security 5 Injects errors into transmitted test pattern 61200185L3 1 Quad T1 PRI Module User Manual 3 9 Chapter 3 Operation ATLAS FEATURES USED WITH QUAD T1 PRI MODULE FACTORY RESTORE Run SELF TEST In addition to the Quad T1 PRI Module menu items two other ATLAS menu items may be operated in conjunction with the Quad T1 PRI Module These are FACTORY RESTORE and Run SELF TEST FACTORY RESTORE restores the factory installed default setting for all Quad T1 PRI Module parameters When Factory Resto
8. of DS0s ATLAS uses for this endpoint A 2 Quad T1 PRI Module User Manual 61200185L3 1 Appendix A Dial Plan Interface Configuration OUTGOING NUMBER CONVERSION AS DIALED DEFAULT ISDN NATIONAL PREFERRED ISDN SUBSCRIBER PREFERRED ISDN NATIONAL DMS RESERVED PREFERRED NETWORK SPECIFIC FACILITY Write security 3 Read security 5 Converts outgoing towards the network numbers to the selected number ing plan and type option Makes a number conversion The outgoing numbering plan and type are forwarded to the network as received and digits are passed As dialed Regardless of the type of number received the outgoing number is substi tuted with ISDN National as the number plan and type Ten digits are always sent to the network Leading ones if present are stripped out and the area code provisioned under DIAL PLAN GLOBAL PARAMETERS is added if only seven digits are supplied This action may be required in areas with ten digit local dialing Examines the incoming number and if seven digits are received or if a ten digit number is received with an area code that matches the area code pro visioned in the global parameters the number is forwarded to the network as a seven digit number defined as ISDN Subscriber number plan and type If the incoming number is ten digits but with a different area code it is for warded to the network as ISDN National preferred Ignores the incoming numbering plan and type a
9. window To access the Quad T1 PRI Module activate the MODULES menu The following sections describe the menu items for the MODULES menu navigating through the terminal menu Win Refer to the ATLAS User Manual for detailed instructions on 61200185L3 1 Quad T1 PRI Module User Manual 3 1 Chapter 3 Operation MODULES The ATLAS system controller automatically detects the presence of the Quad T1 PRI Module when it is installed in the system To see the menus for the Quad T1 PRI Module via the terminal menu use the arrow keys to scroll to the MODULES menu and press Enter to access the module choices Figure 3 1 shows the MODULES menu see also the menu tree in Figure 3 2 System Info sit Type Menu Alarm Test State Status Rev System Status 8 Sys Ctrl ALARM OFF ONLINE Online A System Config 1 T3 D amp I n a n a ONLINE No Response System Utility 2 T1 PRI BE n a n a ONLINE No Response odules 3 ASVNC232 n a n a ONLINE No Response Dedicated Maps U BRI n a n a ONLINE No Response ial Plan 5 T3 n a n a ONLINE No Response 6 H56K 16 1 n a n a ONLINE No Response 7 EMPTY ONLINE Empty 8 U35Nx n a n a ONLINE No Response IE 1 ALRH 2 ALRH 3 ALRM 4 ALRH 5 ALRH 6 ALRM 7 8 ALRH ccess menus for Quad T1 Pri Z help 19 58 Figure 3 1 Modules Menu Slt Part Nu
10. ADRAN Quad T1 PRI Module User Manual Part Number 1200185L3 61200185L3 1A December 1999 ADRAN 901 Explorer Boulevard P O Box 140000 Huntsville AL 35814 4000 256 963 8000 1999 ADTRAN Inc All Rights Reserved Printed in U S A ADTRAN Year 2000 Y2K Readiness Disclosure ADTRAN has established a Year 2000 program to ensure that our products will correctly function in the new millennium ADTRAN warrants that all products meet Year 2000 specifications regardless of model or revision Information about ADTRAN s Year 2000 compliance program is available at the fol lowing Product Matrix www adtran com y2kfax html E mail year2000 adtran com Faxback Document Line 256 963 8200 Y2K plans and product certifications are listed in the Product Matrix see above Y2K Project Line 256 963 2200 FCC regulations require that the following information be provided in this manual to the customer 1 This equipment complies with Part 68 ofthe FCC rules The required label is affixed to the bottom of the chassis 2 AnFCC compliant telephone cord and modular plug is provided with this equipment This equip ment is designed to be connected to the telephone network or premises wiring using a compatible modular jack which is Part 68 compliant See Chapter 2 Installation for details 3 If your telephone equipment Quad T1 PRI Module causes harm to the telephone network the telephone company may discontinue your serv
11. AM ORT EA I D Tie TRITT 3 4 Offline ios terio ise d e hots s cb ce Hs Nowe tat Busi ias 3 4 Offline No Response surtidas loba adios 3 4 Rev 2 2 22 AO ERBE TREND RM E EIER SEN EHER eee ees 3 4 Modules MEA RH Ote kt os as tne testen ai ee ee 3 4 lind EE 3 5 Part N mbet tii diia abes rp dida sein 3 5 Serial Number a i ee Recte tee dh os See E Ra htt Eee seed Ba et 3 5 PLL Status cinema e Dao nip alt ee e et e OH Ree 3 5 Board Revisi n ss tuit feet isi im tore i tessa wer bon Pesos 3 5 Alarm Status asian nepos rre eic niuis 3 5 61200185L3 1 Quad T1 PRI Module User Manual ix Table of Contents Pit isesiiiensisissasl nitieh elliesnl ssentansielingis lsttehmetdiiiiksnllinhiilliunehtisen 3 5 Alarm S ee POP ee oe 3 5 LOS A I EE a CAS N Bic MI EE ER END 3 5 Red an rn aii ea e d p PT D ede aae 3 5 bf ze 3 5 Blend E 3 5 SO Alarm a a Ne a a E CAU Te AERE T Te eU Ee a od 3 5 RE E A A E E H 3 5 DSO Stats sic ah hess need ito di 3 6 DS Al rms ciao ara aang 3 6 DIO LAUSANA Es EO O Dn ES DROS SEC dessen VP TER NE 3 6 Performance Curt pi aene coin elei eet Le eae E e PURA 3 6 lu gm aid 3 6 CER iia dd dani 3 6 ES ru 3 6 BES 2 2 E 3 6 SEES EDS 3 6 SEES edo re Adios 3 6 TQ C5255 cs Se Secs as ann a a Sos os a nee ln Ss NE 3 6 CSS rn AS PRES TPE oce nai taie ea GADD Up D D Reb 3 6 WAS v
12. BER OF DSOS write security 3 Read security 5 Specifies the number of DS0s ATLAS uses for this endpoint 61200185L3 1 Quad T1 PRI Module User Manual A 7 Appendix A Dial Plan Interface Configuration DSOs AVAILABLE Read security 5 SIGNALING METHOD DID DID DiciTS TRANSFERRED Indicates which DS0s of the T1 have been defined in this switched endpoint UN indicated by in another switched endpoint indicated by s or ina dedicated map indicated by n digits 0 9 This DSO is available The digit that displays in this field rep resents the last digit of the D50 number This port is requesting this DSO for this connection but the DSO is not yet activated This DSO is used by this endpoint This DSO is used elsewhere in the switched DIAL PLAN S This DSO is in the switched dial plan and conflicts with this endpoint This DSO is used in one or more DEDICATED MAPS N This DSO is in one or more DEDICATED MAPS and conflicts with this endpoint Write security 3 Read security 5 Defines to ATLAS the type of signaling to be used across this trunk The selected signaling must match that being used by the user equipment PBX The choices are as follow e E amp M Immediate e E amp M Wink e Loop Start e Ground Start ATLAS converts signaling types between network and user terminations Defines to ATLAS whether Direct Inward Dialing DID is used by the user equipment If DID is ENABLED
13. GOING CALL AcCEPT and REJECT NUMBERS discussed in the ATLAS User Manual NUMBER OF DSOS write security 3 Read security 5 DSOs AVAILABLE Specifies the number of DS0s ATLAS uses for this endpoint Read security 5 Indicates which DS0s of the T1 have been defined in this switched endpoint UN indicated by in another switched endpoint indicated by s or ina A 4 Quad T1 PRI Module User Manual 61200185L3 1 Appendix A Dial Plan Interface Configuration DEDICATED MAP indicated by n This field is read only The following characters may display in this field digits 0 9 This DSO is available The digit that displays in this field rep resents the last digit of the DSO number This port is requesting this DSO for this connection but the DSO is not yet activated This DSO is used by this endpoint This DSO is used elsewhere in the switched DIAL PLAN S This DSO is in the switched dial plan and conflicts with this endpoint n This DSO is used in one or more DEDICATED MAPS N This DSO is in one or more DEDICATED MAPS and conflicts with this endpoint SIGNALING Write security 3 Read security 5 METHOD Defines to ATLAS the type of signaling to be used across this trunk The sig naling selected needs to match the signaling being provided by the network PSTN The following choices are available e E amp M Immediate e E amp M Wink e Loop Start e Ground Start DID Write security 3 Read sec
14. I MODULE OVERVIEW The Quad T1 PRI Module P N 1200185L3 is a member of the ATLAS fam ily of integrated access products and provides four channelized T1 or Prima ry Rate ISDN PRI interfaces Each interface can operate independently in DS 1 or DSX 1 mode and any port can serve as the primary or backup tim ing source for the entire system The Quad T1 PRI Module combines with the ATLAS Base Unit and other ATLAS modules to support requirements calling for multiple T1 and or PRI circuits You can install into the system as many Quad T1 PRI Modules as can be physically accommodated in the ATLAS chassis Typical applications calling for ATLAS and the Quad T1 PRI Module in clude the following e Digital Access Cross Connect System DACS Any DSO on any T1 cir cuit can be switched to any other DS0 on any other T1 circuit e T1 Bandwidth Management T1 circuits carrying voice data video and other traffic can have their payload groomed and directed to the appro priate interface inside the ATLAS system see Figure 1 1 e ISDN Access Switch When combined with the Octal BRI U Module P N 1200186L1 L2 the Quad T1 PRI Module can combine multiple Ba sic Rate ISDN BRI circuits onto one or more Primary Rate ISDN PRI cir cuits c gt _ TIZEDI Remote Locations System Controller Quad T1 PRI t ES ATLAS Bussing System ATLAS t t t Quad T1 PRI Quad Nx 56 64 Quad Nx 56 64 ole X344 43113 DSX 1 V
15. Nortel InWats AT amp T Accunet e Nortel OutWats e AT amp T Long Distance e Nortel Foreign Exchange e AT amp T International 800 e Nortel Tie Trunk e AT amp T Dial It 900 Multiquest CALLED DiGITS Write security 3 Read security 5 TRANSFERRED Defines to ATLAS the number of digits to forward from the called number 8 When attached to a PBX the PBX may be provisioned to expect to receive fevver than all of the called digits of the incoming call hovvever this option would normally be set to ALL OUTGOING Write security 3 Read security 5 CALLER ID Defines the number for ATLAS to use to provide Caller ID to the Network for outgoing calls sent through this endpoint This option only displays if DIRECT INWARD DIALING is set to DISABLED This item is optional Win The Caller ID number must be specific i e no wild cards QUAD T1 PRI MODULE USER TERMINATION RBS When you are working in the user termination section of the DIAL PLAN menu when SLT is defined as a T1 PRI module and when SIG is set to RBS the following configuration options are available FIRST DSO Write security 3 Read security 5 Defines to ATLAS the first DSO for this endpoint ATLAS uses DS0s start ing with this selection to send and receive calls to and from the network PSTN The outgoing calls which are allowed or restricted over these DS0s are set by the OUTGOING CALL ACCEPT and REJECT NUMBERS discussed in the ATLAS User Manual NUM
16. al response of the system The module is enabled but is not responding to the system controller s sta tus polls This response indicates either a problem in the system or that the module is not installed The system controller has not detected the presence of a module in the slot nor has a module been manually enabled for this option slot The module is installed but has been taken Offline by a user The module is still responding to controller polls The module is installed but has been taken Offline by a user The module is not responding to controller polls Read security 5 Hardware Revision Read only field that displays the hardware revision of the Quad T1 PRI Module Figure 3 3 shows the MODULES MENU options The following sections de scribe these menu options Refer also to the menu tree shown in Figure 3 2 Info Module Alarns Alarm Status Test Activity DSB Status DSO Alarms Sig Status Performance Curr Performance 15Hin Performance 24Hr Configuration Test Da ara Lara Lara Lara Lara Lam Lara Lara Lara A A e baen SYS OK CSU ALRH 1 ALRM 2 ALRM 3 ALRM 4 ALRM S ALRM 6 ALRM 7 8 ALRHM Access menus for Quad T1 Pri 2 help 19 57 Figure 3 3 Quad T1 PRI Menu Options 3 4 Quad T1 PRI Module User Manual 61200185L3 1 Chapter 3 Operation INFO PART NUMBER SERIAL NUMBER PLL STATUS BOARD REVISION ALARM STATUS PRT ALARMS Rx LEVEL Read security
17. dule User Manual 61200185L3 1 Chapter 3 Operation OVERVIEW You can configure and control the Quad T1 PRI Module from a variety of sources including the following e The ATLAS front panel providing minimal configuration and status support e The terminal menu allowing detailed configuration status and diag nostics SNMP primarily for reporting alarm conditions and system status The remainder of this chapter describes the menu items available when managing the Quad T1 PRI Module via the terminal menu Access the terminal menu using either a VT 100 terminal attached to the ATLAS Base Unit s control port or a Telnet session established through the Base Unit s Ethernet port The ATLAS User Manual provides detailed instructions on the operation of each of these management approaches To edit items in the terminal menu you must have the appropriate password level Each menu description in this section indicates the password level required for write and read access See Access b Passwords in the ATLAS User Manual for detailed information on working with passwords Security level 0 users can view and edit every available field Security level 5 users can view any field but cannot edit TERMINAL MENU STRUCTURE ATLAS uses a hierarchical menu structure to provide access to all of its fea tures The top most menu level leads to submenus which are grouped by functionality All menu items display in the terminal
18. e available SWITCH TYPE Write security 3 Read security 5 Defines the type of PRI switch that ATLAS is going to emulate If connected to another ATLAS both need to be set to the same switch type e Lucent 5E e AT amp T 4ESS FIRST DSO Write security 2 Read security 5 Defines to ATLAS the first DSO for this endpoint ATLAS uses DS0s start ing with this selection to send and receive calls to and from the network PSTN The outgoing calls which are allowed or restricted over these DS0s are set by the OUTGOING CALL ACCEPT and REJECT NUMBERS discussed in the ATLAS User Manual NUMBER OF DSOS write security 3 Read security 5 Specifies the number of DS0s ATLAS uses for this endpoint NETWORK Write 3 Read 5 SPECIFIC Enables the sending of appropriate information to the PSTN The default for this option is NORMAL and in this case no Network Specific Facility FACILITY information element is sent Unless one of the services listed below is sub scribed to the selection should remain set to NORMAL A 6 Quad T1 PRI Module User Manual 61200185L3 1 Appendix A Dial Plan Interface Configuration The list below indicates services that may be subscribed to from the PSTN These services require that specific information such as a Network Specific Facility information element be sent to the network during call setup e AT amp TSDN e National ISDN INWATS e AT amp T Megacom 800 e Nortel Private Network AT amp T Megacom e
19. ection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio frequencies Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be re quired to correct the interference at his own expense Shielded cables must be used with this unit to ensure compliance with Class A FCC limits Change or modifications to this unit not expressly approved by the party responsible for N X Ww ARNING compliance could void the user s authority to operate the equipment Affidavit Requirements for Connection to Digital Services e Anaffidavitisrequired to be given to the telephone company whenever digital terminal equipment without encoded analog content and billing protection is used to transmit digital signals containing encoded analog content which are intended for eventual conversion into voiceband analog signals and transmitted on the network e The affidavit shall affirm that either no encoded analog content or billing information is being transmitted or that the output of the device meets Part 68 encoded analog content or billing protec tion specifications e End user customer will be responsible for filing an affidavit with the local exchange carrier when connecting unpr
20. ennen oed estere eed ee toe ete sates 1 2 Punctional Description steterit e Hte te Rn Hehe iig ot Es 1 2 Features ia i am ep ree Eee SEET a E E OR ER UN ches RENTE ERES E ea ee ER BER at Sacra d 1 2 Quad T1 PRI Module Specifications nenne nennen nennen 1 3 Physical Descriptions spiese ees metere qe der re testet Roa E EERE cet eet nt det ve seinen 1 3 Chapter 2 Installations ainda cotidiana rt iii 2 1 Before Installing the Quad T1 PRI Module sse eene nnne nnne nennen nnne 2 1 Shipping Contents one en atre oreet Ram neh Leg ene e Ne OL ehren 2 1 Installing the Quad T1 PRI Module eese eene eene nenne nnne nnne 2 1 Mois re 2 3 Chapter 3 nicum 3 1 COV EL VIEW sissies Eu M 3 1 Terminal Men StrUctlte iaa teak ios T i D EP ea 3 1 MO ES cien iii olaaa e b ED dr ness SONS 3 2 SES repro AS NER T EN estetica m ere A eR UE NER E Ue San e Vasa ect SER RE 3 3 OS OH HARI EU I RE ii ra E D TU IC He EE Sevens ede 3 3 MOL ts tpe n le Beliebige il b e pet nuo 3 3 Alarm ii are eqni Pe rab er be qa iei 3 3 Test 22 Ec ots 3 3 State RE TN NN eta ees 3 3 Status dne m RO e Hb ds tv d tee ce ta P n DI EHE n don b E e e e SO 3 4 Online Curia EB PPO ea Eee ra o e y 3 4 N6 Responise see 2a u OO URS Tre CD dE as OS EE TRE QR Saee ert ert 3 4 EPI il atin ae et us da ea R
21. ice temporarily If possible they will notify you in advance But if advance notice isn t practical you will be notified as soon as possible You will be advised of your right to file a complaint with the FCC 4 Yourtelephone company may make changes in its facilities equipment operations or procedures that could affect the proper operation of your equipment If they do you will be given advance no tice to give you an opportunity to maintain uninterrupted service 5 If you experience trouble with this equipment Quad T1 PRI Module please contact ADTRAN at 256 963 8000 for repair warranty information The telephone company may ask you to discon nect this equipment from the network until the problem has been corrected or until you are sure the equipment is not malfunctioning This unit contains no user serviceable parts 7 The following information may be required when applying to your local telephone company for leased line facilities a Service Type REN SOC FIC USOC 1 544 Mbps SF 6 0N 04DU9 BN RJ 48C 1 544 Mbps SF and B8ZS 6 0N 04DU9 DN RJ 48C 1 544 Mbps ESF 6 0N 04DU9 1KN RJ 48C 1 544 Mbps ESF and B8ZS 6 0N 04DU9 1SN RJ 48C ISDN 6 0N 04DU9 ISN RJ 48C Federal Communications Commission FCC Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class A digital device pur suant to Part 15 of the FCC Rules These limits are designed to provide reasonable prot
22. ine codes 1 3 line rate 1 3 terminating impedance 1 3 tests 1 3 support 2 3 T technical support 2 3 test 3 8 test pattern 3 9 W warranty vii 2 3 wiring 2 3 Y Y2K iii Index 2 Quad T1 PRI Module User Manual 61200185L3 1 Product Support Information Pre sales Inquiries and Applications Support Please contact your local distributor ADTRAN Applications Engineering or ADTRAN Sales Applications Engineering 800 615 1176 Sales 800 827 0807 Post Sale Support Please contact your local distributor first If your local distributor cannot help please contact ADTRAN Technical Support and have the unit serial number available Technical Support 888 AADTRAN Repair and Return If ADTRAN Technical Support determines that a repair is needed Technical Support will coordinate with the Custom and Product Service CAPS department to issue an RMA number For information regarding equipment currently in house or possible fees associated with repair contact CAPS directly at the following number CAPS Department 256 963 8722 Identify the RMA number clearly on the package below address and return to the following address ADTRAN Customer and Product Service 6767 Old Madison Pike Building 6 Suite 690 Huntsville Alabama 35807 RMA
23. ion Cover Plate SET o e Figure 2 1 Installing the Quad T1 PRI Module Instructions for Installing the Quad T1 PRI Module Step Action Remove the cover plate from the appropriate option slot of the ATLAS rear panel Slide the Quad T1 PRI Module into the option slot until the module is firmly positioned against the front of the chassis Secure the thumbscrews at both edges of the module To ensure that the thumbscrews are securely fastened use a screw river to tighten them 2 2 Quad T1 PRI Module User Manual 61200185L3 1 Chapter 2 Installation WIRING Each port ofthe Quad T1 PRI Module uses a single eight position modular jack to connect to the T1 or PRI circuit Table 2 1 on page 2 3 gives the pinout for this jack The required wiring connection is described here Connector Type USOC RJ 48C Table 2 1 Network Connection Pinout PIN NAME DESCRIPTION R1 RXDATA T1 RXDATA UNUSED R TXDATA T TXDATA 7 8 UNUSED O coc A W PD Receive data from the network ring Receive data from the network tip Send data towards the network ring Send data towards the network tip 61200185L3 1 Quad T1 PRI Module User Manual 2 3 Chapter 2 Installation 2 4 Quad T1 PRI Mo
24. l A 1 Appendix A Dial Plan Interface Configuration QUAD T1 PRI MODULE INTERFACE CONFIGURATION The remainder of this appendix discusses the following network and user termination configuration settings for the ATLAS when using the DIAL PLAN menus e Quad T1 PRI Module Network Termination PRI on page A 2 e Quad T1 PRI Module Network Termination RBS on page A 4 e Quad T1 PRI Module User Termination PRI on page A 6 e Quad T1 PRI Module User Termination RBS on page A 7 QUAD T1 PRI MODULE NETWORK TERMINATION PRI When you are working in the network termination section of the DIAL PLAN menu when SLT is defined as a Quad T1 PRI Module and when SIG is set to PRI the following configuration options are available SWITCH TYPE Write security 3 Read security 5 Defines the type of PRI switch to which the port is connected If connected to another ATLAS both need to be set to the same switch type The follow ing options are available e Lucent DE e Northern DMS 100 e National ISDN e AT amp T 4ESS FIRST DSO Write security 3 Read security 5 Defines to ATLAS the first DSO for this endpoint ATLAS uses DS0s start ing with this selection to send and receive calls to and from the network PSTN The outgoing calls which are allowed or restricted over these DS0s are set by the OUTGOING CALL ACCEPT and REJECT NUMBERS discussed in the ATLAS User Manual NUMBER OF DSOS write security 3 Read security 5 Specifies the number
25. mat Choose either ON or OFF 61200185L3 1 Quad T1 PRI Module User Manual 3 7 Chapter 3 Operation TEST LBO LB AcCEPT PULSE DENSITY PRT Loc LB Write security 2 Read security 5 Selects the Line Build Out LBO for the network interface When connect ing a Quad T1 PRI Module port to a DSX 1 interface this parameter is typ ically set to match the distance in feet between ATLAS and the device with which it is connecting When you select this item a list of choices displays Select the appropriate option Write security 3 Read security 5 Sets unit to accept or reject the in band loop up and loop down codes as defined in ANSI T1 403 This is a line loopback Choose either ACCEPT or IGNORE Write security 3 Read security 5 Choose either ON or OFF When ON Pulse Density Enforcer causes the ATLAS to monitor for ones 1s density violations and insert a one 1 when needed to maintain ones at 12 5 This data insertion will cause data errors Write security 4 Read security 5 These options initiate different types of tests and display test results CAUT These test commands temporarily disrupt service Read security 5 Displays the port number Write security 4 Read security 5 Causes loopback on near end local port see Figure 3 4 on page 3 9 The following options are available LINE Metallic loopback PAYLD Payload loopback framing and clocking are regenerated 3 8
26. mber Type Info Serial Number T1 PRI Menus Board Revision PLL Status LOS Menu Module Alarms Alarm Status Prt Red shortcut Alarms Yellow Rx Level Blue Prt DSO Alarm DSO Status CLR Modules DSO Alarms ES Alarm Sig Status BES Test SES Prt State Performance Curr SEFS Port Name Status 15Min and 24Hr LOFC Frame Rev CSS Code UAS Tx Yel LCV Tx PRM PCV LBO LES LB Accept Configuration Pulse Density Prt Loc LB Test Activity Remote LB shortcut Pattern QRSS RLB Results Test Clr Inj Figure 3 2 Menu Tree for Quad T1 PRI Modules Menu 3 2 Quad T1 PRI Module User Manual 61200185L3 1 Chapter 3 Operation SLT TYPE MENU LARM TEST STATE Read security 5 Displays the slot number for available option slots in the ATLAS chassis Slot 0 refers to the ATLAS Base Unit This field is read only Write security 3 Read security 5 Displays the type of module currently installed in the slot or the type of module you plan to install in the slot If a Quad T1 PRI Module is installed the Type field automatically defaults to T1 PRI 4 the Quad T1 PRI Mod ule You can also use this field to preconfigure a system before installing modules by specifying the module that you want to install into each slot you want to change this field to a different type of module you must set TYPE to EMPTY before selecting the other module S TYPE automatically displays the name of an installed mod
27. mmunications network protective operational and safety requirements The Department of Commerce does not guarantee the equipment will operate to the user s satisfaction Before installing this equipment users should ensure that it is permissible to be connected to the facil ities of the local telecommunications company The equipment must also be installed using an accept able method of connection In some cases the company s inside wiring associated with a single line individual service may be extended by means of a certified connector assembly telephone extension cord The customer should be aware that compliance with the above conditions may not prevent deg radation of service in some situations Repairs to certified equipment should be made by an authorized Canadian maintenance facility desig nated by the supplier Any repairs or alterations made by the user to this equipment or equipment mal functions may give the telecommunications company cause to request the user to disconnect the equipment Users should ensure for their own protection that the electrical ground connections of the power utility telephone lines and internal metallic waterpipe system if present are connected together This precau tion may be particularly important in rural areas Users should not attempt to make such connections themselves but should contact the appropriate UT electric inspection authority or an electrician as appropriate The Load N
28. nd substitutes the ISDN Telephony numbering plan and National number type Ten digits are sent to the network Leading ones if present are stripped out and the area code set in global parameters is added if only seven digits are supplied This action may be required in areas with ten digit local dialing Write 3 Read 5 Enables the sending of appropriate information to the PSTN The default for this option is NORMAL and in this case no Network Specific Facility Information Element is sent Unless one of the services listed below is sub scribed to the selection should remain set to NORMAL The list below indicates services that may be subscribed to from the PSTN These services require that specific information such as a Network Specific Facility Information Element be sent to the network during call setup e AT amp T SDN e National ISDN INWATS e AT amp T Megacom 800 e Nortel Private Network AT amp T Megacom e Nortel InWats AT amp T Accunet e Nortel OutWats e AT amp T Long Distance e Nortel Foreign Exchange e AT amp T International 800 e Nortel Tie Trunk e AT amp T Dial It 900 Multiquest 61200185L3 1 Quad T1 PRI Module User Manual A 3 Appendix A Dial Plan Interface Configuration CALLED DIGITS TRANSFERRED PREFIX OUTGOING CALLER ID Write security 2 Read security 5 Some PRI switches may be provisioned to send only a portion of the called number like DID This menu item allows ATLAS to know ho
29. ode Violations Line Errored Seconds Write security 4 Read security 5 Stores the performance data for the previous 15 minute window Refer to Performance Current on page 3 6 for a detailed description of these fields Write security 4 Read security 5 Stores the performance data for the previous 24 hour window Refer to Per formance Current on page 3 6 for a detailed description All of the following configurable parameters apply to whether the port is connected to a Primary Rate ISDN circuit or a channelized T1 circuit Read security 5 Displays the port number Write security 3 Read security 5 Accepts any alpha numeric name up to 16 characters long to uniquely identify each port on the Quad T1 PRI Module Write security 2 Read security 5 This field must be set to match the frame format of the circuit to which it is connected available from the network supplier Choose either D4 or ESF Write security 2 Read security 5 Set this field to match the line code of the circuit to which it is connected this information is available from the network supplier Choose either AMI or B8ZS Write security 3 Read security 5 Controls the transmitting of yellow alarms Choose either ON or OFF Write security 3 Read security 5 Controls the sending of performance report messaging PRM data on the facility data link FDL The PRM data continues to be collected even if XMIT PRM is turned off possible only with ESF for
30. otected customer premise equipment CPE to 1 544 Mbps or subrate digital ser vices e Until such time as subrate digital terminal equipment is registered for voice applications the affi davit requirement for subrate services is waived Affidavit for Connection of Customer Premises Equipment to 1 544 Mbps and or Subrate Digital Services For the work to be performed in the certified territory of telco name State of County of L name business address telephone number being duly sworn state Ihave responsibility for the operation and maintenance of the terminal equipment to be connected to 1 544 Mbps and or subrate digital services The terminal equipment to be connected complies with Part 68 of the FCC rules except for the encoded analog content and billing protection specifica tions With respect to encoded analog content and billing protection Iattest that all operations associated with the establishment maintenance and adjustment of the digital CPE with respect to analog content and encoded billing protection information continu ously complies with Part 68 of the FCC Rules and Regulations The digital CPE does not transmit digital signals containing encoded analog content or billing information which is intended to be decoded within the telecommunications network The encoded analog content and billing protection is factory set and is not under the control of the customer I attest that
31. r PRI e AT amp T 62411 and ANSI T1 403 compliant e Diagnostic loopback support e Various timing options e T1 ESF diagnostics e Bantum monitor jacks on each interface e Performance per ANSI T1 403 AT amp T 54016 and ANSI T1 102 e RJ 48C network interface connector e AMI or B8ZS coding e ESF or SF D4 framing e Line build out settings DSX 1 0 to 655 feet in 133 foot increments DS 1 22 5 15 7 5 and 0 dB e Monitor jack e Line loopback VT 100 remote in band e Payload loopback 1 2 Quad T1 PRI Module User Manual 61200185L3 1 Chapter 1 Introduction e PRI switch support for the following switches AT amp T 5ESS NT or LT Nortel DMS 100 NT or LT NI 2NT network termination e Supports the inherent DACS capability of the ATLAS e Reports line performance data via SNMP in RFC1406 format e Trunk conditioning Quad T1 PRI Module Specifications Each port of the Quad T1 PRI Module conforms to the following specifica tions Line rate 1 544 Mbps 75 bps Capacity T1 1 to 24 DSOs PRI 23B D Line Codes AMI alternate mark inversion or B8ZS bipolar return to zero Framing D4 or ESF Tests Self test line loopback port loopback Connectors RJ 48C eight position modular jack Terminating 100 ohms 5 Impedance PHYSICAL DESCRIPTION The Quad T1 PRI Module see Figure 1 2 plugs into any available option slot in the rear of the ATLAS chassis 0 ferries Figure 1 2 Quad T1 PRI Module
32. re displays place the cursor on it and press Enter The unit is restored to preset factory defaults and re turns to the main ATLAS menu RUN SELF TEST a submenu of the ATLAS main menu item TEST executes both the Quad T1 PRI Module internal test and the ATLAS internal test For additional information on SELF TEST see the ATLAS User Manual MAPPING DS0s are used as defined in the DEDICATED MAP or in the DIAL PLAN for switched applications See the ATLAS User Manual for a description Defining a port as a T1 or PRI is determined by the way it is assigned in the DEDICATED MAP or in the DIAL PLAN See Appendix A of this manual for more information on setting up the DiAL PLAN 3 10 Quad T1 PRI Module User Manual 61200185L3 1 Appendix A Dial Plan Interface Configuration The interface configuration options for the DIAL PLAN menu set configura tion parameters for the endpoint These parameters vary by the type of port selected This appendix describes the configuration options available for the ATLAS The DiAL PLAN menus are only accessible when using terminal mode To access these options select DIAL PLAN from the top level ATLAS menu see Figure A 1 Win The Write security level for all DIAL PLAN options is 3 etuor User ystem Info System Status Term Global Paran System Config System Utility lodules Dedicated n Figure A 1 Dial Plan Menus 61200185L3 1 Quad T1 PRI Module User Manua
33. s These alarms usually indicate the failure to receive the protocol that has been configured for the DSO Read security 5 Read only field indicates signaling of all 24 DS0s The A B bits for Rx receive and Tx transmit DS0s are shown for each port Dashes display for those DS0s where robbed bit signaling RBS is not being transferred by ATLAS Write security 4 Read security 5 The performance fields either current 15 minute total or 24 hour total provide status on key performance measures as specified in ANSI T1 403 and AT amp T TR54016 for each of the four T1 PRI ports Excepting CLR these fields are all read only The monitored parameters include the following Displays the port number Clears performance information for the selected port An Errored Seconds ES is a second with one or more error events OR one or more Out Of Frame events OR one or more Controlled Slips A Bursty Errored Seconds BES is a second with more than one but less than 320 error events A Severely Errored Second SES is a second with 320 or more error events OR one or more Out Of Frame events Severely Errored Frame Seconds Loss of Frame Count Controlled Slip Seconds 3 6 Quad T1 PRI Module User Manual 61200185L3 1 Chapter 3 Operation UAS LCV PCV LES PERFORMANCE 15MIN PERFORMANCE 24HR CONFIGURATION PRT PORT NAME FRAME CODE Tx YEL Tx PRM Unavailable Seconds Line Code Violations Path C
34. the operator s maintainer s of the digital CPE responsible for the establishment mainte nance and adjustment of the encoded analog content and billing information has have been trained to perform these functions by successfully having completed one of the following check appropriate blocks A A training course provided by the manufacturer grantee of the equipment used to encode analog signals or B A training course provided by the customer or authorized representative using training mate rials and instructions provided by the manufacturer grantee of the equipment used to encode analog signals or C An independent training course e g trade school or technical institution recognized by the manufacturer grantee of the equipment used to encode analog signals or D Inlieu of the preceding training requirements the operator s maintainer s is are under the control of a supervisor trained in accordance with circle one above I agree to provide telco s name with proper documentation to demonstrate compliance with the information as provided in the preceding paragraph if so requested Signature Title Date Transcribed and sworn to before me This day of I Notary Public My commission expires vi Canadian Equipment Limitations The Industry Canada Certification label identifies certified equipment This certification means that the equipment meets certain teleco
35. then the following information must be defined Defines the number of digits ATLAS sends on to the user equipment This field only displays if DID is set to ENABLED A 8 Quad T1 PRI Module User Manual 61200185L3 1 Appendix A Dial Plan Interface Configuration CALLER ID NUMBER Defines the number ATLAS uses to provide caller ID to the network for out going calls sent through this endpoint This option only displays if DID is set to DISABLED This item is optional Win The Caller ID number must be specific i e no wild cards 61200185L3 1 Quad T1 PRI Module User Manual A 9 Appendix A Dial Plan Interface Configuration A 10 Quad T1 PRI Module User Manual 61200185L3 1 Index A applications typical 1 1 ATLAS menus Factory Restore 3 10 Run Self Test 3 10 C customer service vii 2 3 F Factory Restore 3 10 FCC statement iv IFCE CONFIG NETWORK TERM PRI A 2 CALLED DIGITS TRANSFERRED A 4 FIRST DSO A 2 NETWORK SPECIFIC FACILITY A 3 NUMBER OF DS0S A 2 OUTGOING CALLER ID A 4 OUTGOING NUMBER CONVERSION A 3 PREFIX A 4 SWITCH TYPE A 2 IFCE CONFIG NETWORK TERM RBS A 4 DID A 5 DID DIGITS TRANSFERRED A 5 DID PREFIX A 5 DS0S AVAILABLE A 4 FIRST DSO A 4 NUMBER OF DSOs A 4 SIGNALING METHOD A 5 TRUNK NUMBER A 6 IFCE CONFIG USER TERM PRI A 6 CALLED DIGITS TRANSFERRED A 7 FIRST DSO A 6 NETWORK SPECIFIC FACILITY A 6 NUMBER OF DS0S A 6 OUTGOING CALLER ID A 7 SWITCH TYPE A
36. ule If Displays additional status and configuration menus for the selected module To access the submenus for this item use the arrow keys to scroll to the Menu column for the module you want to edit and press ENTER For de tailed information on each submenu item see Modules Menu on page 3 4 Read security 5 Displays an alarm condition on the Quad T1 PRI Module Press ENTER in this field to activate the Alarm menu Read security 5 Displays tests that the Quad T1 PRI Module is executing Press ENTER in this field to activate the Test menu Write security 3 Read security 5 Indicates the module status either online or offline Even though a module is physically installed it must be marked Online to be considered an avail able resource You can mark an installed module Offline which may be useful in system troubleshooting If you choose Offline the module will not be in alarm condition but will display Offline A module must be in the Online state in order for ATLAS to use the module for any data bandwidth 61200185L3 1 Quad T1 PRI Module User Manual 3 3 Chapter 3 Operation STATUS REV MODULES MENU ONLINE No RESPONSE EMPTY OFFLINE OFFLINE NO RESPONSE Read security 5 Read only field that presents status information on the Quad T1 PRI Module The following messages may display The module is enabled and is responding to the system controller s status polls This is the norm
37. umber LN assigned to each terminal device denotes the percentage of the total load to be connected to a telephone loop which is used by the device to prevent overloading The termination on aloop may consist of any combination of devices subject only to the equipment that the total of the LNs of all devices does not exceed 100 The ringer equivalence number REN assigned to each terminal adapter is used to determine the total number of devices that may be connected to each circuit The sum of the RENs from all devices in the circuit should not exceed a total of 5 0 Warranty and Customer Service ADTRAN will replace or repair this product within five years from the date of shipment if the product does not meet its published specification or if it fails while in service For detailed warranty repair and return information refer to the ADTRAN Equipment Warranty and Repair and Return Policy Proce dure see the last page of this manual A return material authorization RMA is required prior to returning equipment to ADTRAN For service RMA requests or more information see the last page of this manual for the toll free contact number vii viii Table of Contents List Of Figures xiii List Of Tales E xv Chapter 1 Tri tr AU Cti O10 siii diia 1 1 Quad TARR Module Overview ar aio 1 1 NEBS Eompliance 22 eite em ere ea n
38. urity 5 Defines to ATLAS whether Direct Inward Dialing DID is being used by the network If DID is ENABLED then the following information must be defined DID DIGITS Write security 3 Read security 5 TRANSFERRED Defines the number of digits sent to ATLAS from the network if DID is used DID PREFIX Write security 3 Read security 5 Defines to ATLAS the prefix digits which are not received as a part of the DID number ATLAS uses the combination of prefix and DID number to determine the user endpoint that should receive the incoming call This option only displays if DID is set to ENABLED If DID is DISABLED then you must define the trunk number 61200185L3 1 Quad T1 PRI Module User Manual A 5 Appendix A Dial Plan Interface Configuration TRUNK NUMBER Write security 3 Read security 5 When the network connection does not provide DID digits ATLAS must be given a number to use to determine which user endpoint should receive the incoming call TRUNK NUMBER displays only when DID is set to DISABLED Win The trunk number must be specific i e no wild cards EXAMPLE To connect an incoming DSO trunk to an endpoint with the ACCEPT num ber of 963 8615 set the trunk number to 963 8615 QUAD T1 PRI MODULE USER TERMINATION PRI When you are working in the user termination section of the DIAL PLAN menu when SLT is defined as a T1 PRI module and when SIG is set to PRI the following configuration options ar
39. w many dig its to expect choose from NONE THREE FOUR and ALL The default is ALL and would almost always be correct If less than ALL digits are sent then the PREFIX is defined as shown below Write security 2 Read security 5 Displays only if CALLED DiGITS TRANSFERRED is not set to ALL Enter the prefix for the digits received EXAMPLE If the number of digits is four and the number called is 963 8005 the telco s PRI switch sends only 8005 and the prefix is set to 963 This entire number is then used to determine which ATLAS User port endpoint should receive the call Write security 3 Read security 5 Defines the number for ATLAS to use to provide Caller ID to the Network for outgoing calls sent through this endpoint This option only displays if DiRECT INWARD DiALING is set to DISABLED This item is optional Win The Caller ID number must be specific i e no wild cards QUAD T1 PRI MODULE NETWORK TERMINATION RBS FIRST DSO When you are working in the network termination section of the DIAL PLAN menu when SLT is defined as a Quad T1 PRI Module and when SIG is set to RBS the following interface configuration options are available Write security 3 Read security 5 Defines to ATLAS the first DSO for this endpoint ATLAS uses DS0s start ing with this selection to send and receive calls to and from the network PSTN The outgoing calls which are allowed or restricted over these DS0s are set by the OUT

Download Pdf Manuals

image

Related Search

Related Contents

  User' Guide Handleiding Guide de l'utilisateur  Mode d`emploi fleuve noir minisite  Descargar Manual - Siisa  船舶インシデント調査報告書  Cisco ASR 1000  RESINE EPOXY 1070S/1074  DST nanoRF-T Mercury & Gná - Star-Oddi    I NL BE D F BE  

Copyright © All rights reserved.
Failed to retrieve file