Home

Installation and Configuration Manual

image

Contents

1. E E SW2 Poles 7 amp 8 Baud Rate Select m oN of com 4800 ey 9600 Z 19200 m 38400 SW1 Poles 1 amp 2 X Y XLR Termination ON ON oml X Y on XLR Terminated m X Y on XLR NOT Terminated O vE SPT at end of X Y XLR cable or X Y on XLR not used SPT js in middle of X Y XLR Cable 8L9GHETL SW1 Pole 3 RS 422 Termination ON ON of Unterminated ml Terminated Leave Off Unterminated when configured as RS 232 SW1 Pole 4 Not Used SW1 Pole 5 Source 1 for Disconnect ON 7 ON ol Disconnect from all of Sources on Disconnect Take Source 1 instead of Disconnecting SW1 Pole 6 3 Digit Formatting on Format status and matrix on Format status and matrix cH messages with 2 digit o i messages with 3 digit integers integers SW1 Poles 7 amp 8 Device IDs ON Poll Address ID 8201 m Data Address ID 8202 Leitch Device ID 01 Default setting ON Poll Address ID 8203 Data Address ID 8204 Leitch Device ID 03 8 E Figure 4 2 DIP Switch Settings Poll Address ID 8205 Data Address ID 8206 Leitch Device ID 05 SPT TANDBERGTOLXY Serial Protocol Translator Installation and Configuration Manual ON Poll Address ID 8207 Data Address ID 8208 Le
2. 4 Chapter 3 Installing the SPT TANDBERGTOLXY 5 Installing the SPT TANDBERG FOEXY 5 Connecting the SPT TANDBERGTOLXY cece eee eee eee 6 Cable Wiring Details 2 eons says Gas oo 8 Chapter 4 Configuring the SPT TANDBERGTOLXY 9 Configuring the SPT TANDBERGTOLXY 9 Reassembling the Unit iersinii aienea eae wedawe RE aS 12 Protocol Notttee Ei A RRA ae eee ay 13 Configuration Control 13 Protocol Commands aseo sans AP thai O a a E Pasties 15 Referenc m nkara a See Ohare O RA EREE AAEE E a 17 Appendix A Safety cccccccccccccccccccccccecee 19 Safety Terms and Symbols in this Manual 19 Safety Terms and Symbols on the Product 19 Preventing Electrostatic Discharge 20 Injury PrecaUHONSyi 3 3 4 fae See 21 Product Damage Precautions 22 Battery Use Warnings 0 0 cc cece cece cece eee ee eee a EN 23 SPT TANDBERGTOLXY Serial Protocol Translator Installation and Configuration Manual iii Contents iv SPT TANDBERGTOLXY Serial Protocol Translator Installation and Configuration Manual Chapter 1 General Information This manual provides information o
3. e Alarm Text Name e Matrix Status Change Matrix Status Polling e Reset e Matrix Size Linked Level Offset e Host Controller Release Number Tributary Information Alarm Messages A The SPT TANDBERGTOLXY supports these alarm status messages 00 No alarm 02 Frame communication failure 03 Hardware problem fan power supply etc Text Name Messages DO and DI Text names furnished in the response have the following forms For inputs I lt 3 digit decimal 1 based number of input gt IN lt space gt lt 3 digit decimal 1 based number of input gt lt space gt lt space gt Example I010IN 010 SPT TANDBERGTOLXY Serial Protocol Translator Installation and Configuration Manual 15 Chapter 4 e For outputs O lt 3 digit decimal 1 based number of input gt OUT lt space gt lt 3 digit decimal 1 based number of input gt lt space gt Example O010OUT 010 Matrix Status Messages S or M Refer to the Sandar Prosan Protocol User Manual for an explanation of Matrix Status Messages Change Matrix Status Messages M Only one Matrix Status Response message will be issued for each level specified in the command message Other levels in the message will be expressed with the don t care no change parameter For example Request M001 001 002 003 Responses M001 001 M001 002 M001 003 Polling Messages Q Resulting responses will be Q00 Reset Messages R Followi
4. Here is an example of a Status response message formatted in 3 digit mode SA 01 02 03 04 05 06 07 08 Here is an example of a Matrix message formatted in 3 digit mode MO01 01 02 03 04 05 06 07 08 Device IDs SW1 Poles 7 and 8 The SW1 Poles 7 and 8 provides a selectable address range Sandar Prosan protocols require a device to have two addresses starting at the value 8200 The addresses are referred to as the Poll Address which is always odd and the Data Address which is always even The Leitch Device ID which is seen by Leitch products on the X Y bus is the DIP switch value see Table 4 1 The Poll Address of the SPT is the constant value 8200 added to the DIP switch value selected see Table 4 1 The Data Address is equal to the Poll Address plus 1 see Table 4 1 Table 4 1 shows SW1 poles 7 and 8 DIP switch settings with corresponding Leitch device IDs Poll Addresses and Data Addresses 14 SPT TANDBERGTOLXY Serial Protocol Translator Installation and Configuration Manual Configuring the SPT TANDBERGTOLXY Table 4 1 SPT TANDBERGTOLXY Device IDs SW1 Poles7 8 Leitch Device DIP Switch ID DIP Switch settings value Poll Address Data Address 00 01 8201 8202 01 03 8203 8204 10 05 8205 8206 11 07 8207 8208 Protocol Commands The SPT TANDBERGTOLXY protocol supports the following Prosan message types These message types are explained in detail in subsequent sections
5. recommends that you keep at least one set of original packaging in case a prod uct needs to be returned for service If the original package is not available you can purchase replacement packaging from Leitch or supply your own packaging as long as it meets the following criteria Packaging must be able to withstand the product weight The product must be held rigid within the packaging There must be at least two inches of space between the product and the container The corners of the product must be protected Products returned for servicing should be shipped to Leitch by prepaid shipment If the product is still within the warranty period the product will be returned by pre paid shipment after servicing Safety Carefully review all safety precautions to avoid injury and prevent damage to this product or any products connected to it You will find a complete list of safety precau tions in Appendix A IMPORTANT Only qualified personnel should perform service procedures Safety Terms and Symbols in this Manual A DANGER Statements identifying conditions or practices that will result in severe personal injury or loss of life High voltage is present Statements identifying conditions or practices that may result in personal injury or loss of life High voltage is present A CAUTION Statements identifying conditions or practices that can result in damage to the equipment or other property Revision History
6. 22 operation RS 232 Serial port baud rate 9600 baud X Y on XLR termination the XLR ports must be terminated if the SPT is located at the end of the Terminated bus Source 1 for disconnect Yes 3 digit formatting Yes SPT address ID 0 Reconfiguration is accomplished via DIP switch and jumper settings as shown in Figure 4 1 and Figure 4 2 Chapter 4 Jumper Pack SW3 Orientation U5 Firmware Identification RS 232 RS 422 Firmware Type Must be SPT23 for TANDBERGTOLXY application contact Leitch Customer Service if firmware type is not SPT23 Firmware Level Will vary as new releases are developed Checksum Will vary as new releases are developed D XeJJ5 Imi Ua Ul Ua US PSUS SY DL eS A Ligh Fak Ut ALL Se AE A oO Suitcase Jumpers Jumper Designator Not installed Not installed Default setting Figure 4 1 DIP Switch and Jumper Locations 10 SPT TANDBERGTOLXY Serial Protocol Translator Installation and Configuration Manual Configuring the SPT TANDBERGTOLXY SW2 Poles 1 6 Protocol Select ol 2 SPT TANDBERGTOLXY Must be set to this setting to operate in the TANDBERGTOLXY mode 284 24 LL
7. Edition Date Comments Edition A August 2002 Initial release 2 SPT TANDBERGTOLXY Serial Protocol Translator Installation and Configuration Manual Chapter 2 Introducing the SPT TANDBERGTOLXY Introducing the SPT TANDBERGTOLXY The SPT serial protocol translator is a compact adapter that translates between Leitch protocol and protocols used by other manufacturers or equipment The SPT can be used to integrate otherwise incompatible devices in a system and it may be used to expand a system beyond the normal limitations imposed by hardware or system design The SPT is available in several modes each of which is covered in a separate manual For a complete list of available models refer to the SPT Applications Guide Figure 2 1 SPT Serial Protocol Translator SPT TANDBERGTOLXY Serial Protocol Translator Installation and Configuration Manual 3 Chapter 2 Applications Involving the SPT TANDBERGTOLXY The SPT TANDBERGTOLXY may be used in conjunction with a Leitch routing switcher to allow control of the switcher via Tandberg Control Console with Prosan protocol support In this application the SPT will translate from Prosan protocol to the protocol required by the Leitch routing switcher see Figure 2 2 Edit controller to router interface software written for Sandar routers Tandberg controller See cable wiring details RS 232 RS 422 SPT TANDBERGTOLXY Serial protocol translator provides conversion fr
8. S 422 SPT TANDBERGTOLXY Serial protocol translator provides conversion from Sandar Prosan protocol to Leitch X Y fe ir Fon nunnan fannen LEITH amp oe peel o a o famm a OGEEEO omo oG OGEEEEO OGD OGO OGEEE O oGEEE WA Leitch router frames Leitch RCP p series router control panels Figure 3 1 Connecting the SPT TANDBERGTOLXY 6 SPT TANDBERGTOLXY Serial Protocol Translator Installation and Configuration Manual Installing the SPT TANDBERGTOLXY Port Configured For RS 232 Port Configured For RS 422 RxD Data Received by Router Ta Data Sent by Router TxD Data Sent by Router Rb Data Received by Router round C a Pin 6 8 e DB 9 Male OCO Figure 3 2 Serial Connector Pin Assignments SPT TANDBERGTOLXY Serial Protocol Translator Installation and Configuration Manual 7 Chapter 3 Cable Wiring Details Figure 3 3 shows the connector pin assignments on both ends of the connection the cable wiring description is shown between the connectors Figure 3 4 shows the cable wiring details for connecting the SPT TANDBERGTOLXY to a Tandberg controller Tandberg Controller m Interconnect Cable _ SPT TANDBERGTOLXY Master DB 9 DB 9 Slave DB 9 Male Female Femole DB 9 Male Frame Ground Received Data Ta Transmitted Data Rb Transmit Common Frame Ground 1 Transmitted Data Ta 2 Received Data Rb 3 Received Comm
9. WORKS EZ HD Focused on the Future Genesis HDTV Glue HEDCO Innovision ISIS JUNO LeFont Leitch Leitch Network Systems LNS LogoMAX LogoMotion Media File MediaPort MIX BOX Monarch Motion File OPUS PanelMAPPER PROM Slide RouterWORKS StillFile Still Net Tekniche Unilock VIA ViewGuard Xplus and Leitch XPRESS are trademarks of Imagine Communications or its subsidiaries Microsoft and Windows are registered trademarks of Microsoft Corporation All other trademarks and trade names are the property of their respective companies Contact Information Imagine Communications has office locations around the world For locations and contact information see http www imaginecommunications com contact us Support Contact Information For support contact information see Support Contacts http www imaginecommunications com services technical support eCustomer Portal http support imaginecommunications com Contents Chapter 1 General Information cceccecceee 1 Writing Conventions ccc estre oi cee 1 Unpacking pantie tec Rolie Mattes she E sce Vite ha dig NN te psa Sti 1 Shipping cionci niie re a Ena EE E A OARA EREE EEE a E 2 Safet e een aaa E 6 2 Revision History skis nt ee i hea E EEA eA aa NE 2 Chapter 2 Introducing the SPT TANDBERGTOLXY 3 Introducing the SPT TANDBERGTOLKY 3 Applications Involving the SPI TANDBERGIOLXV
10. cannot respond to the Tandberg controller Once the inter nal status table is built the Tandberg controller will be alerted with a reset message and a series of crosspoint status messages advising the current crosspoint informa tion Following these messages the Tandberg controller can transmit messages to the SPT TANDBERGTOLXY The Sandar Prosan protocol is an ACK NAK protocol that is each message sent will receive an immediate response indicating that the message is either acknowledged ACK or not acknowledged NAK The SPT TANDBERGTOLXY will acknowledge any message with the correct checksum without regard to the command or message content The SPT TANDBERGTOLYXY will not acknowledge messages with the incorrect checksum Likewise if messages sent from the SPT TANDBERGTOLYXY to the host are neither acknowledged or not acknowledged within a 2 second timeframe the message will be retransmitted The message will be transmitted up to 3 times before attempts to send the message are abandoned The SPT TANDBERGTOLXY will stop all communication to and from the Tandberg controller if it detects a loss of communication with the Leitch router Once the SPT TANDBERGTOLYXY reestablishes communication with the router it will reopen communication to the Tandberg controller Allow the SPT TANDBERGTOLXY approximately 30 to 40 seconds to determine loss of or to reestablish communication Configuration Control Source 1 for Disconnec
11. emoved In frames with multiple power supplies remove ALL power cords Power should not be applied to the frame while the top is open unless properly trained personnel are servicing the unit Pull out the plug from the main socket before the removal of a cover Przod zdjeciem pokrywy wyciagnac wtyczke z gniazda sieciowego WARNING SHOCK HAZARD DO NOT OPEN AVIS RISQUE DE CHOC LECTRIQUE NE PAS OUVRIR MOUNT IN RACK ONLY INSTALLER SUR SUPPORT DE MONTAGE SEULEMENT Use proper power cord h To avoid fire hazard use only the power cord specified for this product Ground the product This is a Safety Class 1 product and is grounded through the grounding conductor of the power cord To avoid electrical shock the grounding conductor must be connected to earth ground Before making connections to the product s input or output terminals ensure the product is properly grounded WARNING THIS APPLIANCE MUST BE GROUNDED WARNING THIS APPLIANCE MUST BE EARTHED VARNING APPARATEN SKALL ANSLUTAS TILL JORDAT UTTAG NAR DEN ANSLUTS TILL ETT NATVERK Do Not Operate Without Covers To avoid electrical shock or fire hazard do not operate this product with covers or panels removed Use Proper Fuse To avoid fire hazard use only the fuse type and rating specified for this product Do Not Operate in Wet Damp Conditions To avoid injury or fire hazard do not operate this product in wet or damp conditions SPT TANDBERGTOLXY Ser
12. enden Sie nur Sicherungen mit der f r dieses Produkt geforderten Typ und Stromst rke f CAUTION Indicates a hazard to property including the product or to pay Preventing Electrostatic Discharge Observe precautions for handling electrostatic sensitive devices CAUTION Flectrostatic discharge ESD can damage components in the t 4 product To prevent ESD observe these precautions when directed to do so 1 Use a Ground Strap Wear a grounded antistatic wrist strap to discharge the static voltage from your body while installing or removing sensitive compo nents 2 Use a Safe Work Area Do not use any devices capable of generating or holding a static charge in the work area where you install or remove sensitive components Avoid handling sensitive components in areas that have a floor or benchtop surface capable of generating a static charge 3 Handle Components Carefully Do not slide sensitive components over any surface Do not touch exposed connector pins Handle sensitive components as lit tle as possible 4 Transport and Store Carefully Transport and store sensitive components in a static protected bag or container 20 SPT TANDBERGTOLXY Serial Protocol Translator Installation and Configuration Manual Safety Injury Precautions WARNING Potentially lethal voltages are present within the frame during normal AN operation The AC power cord must be disconnected from the frame before the top panel is r
13. f explosion if battery is incorrectly replaced Replace only with the same or equivalent type recommended by the equipment manufacturer Discard used batteries according to manufacturer s instructions VARNING Explosionsfara vid felaktigt batteribyte Anvand samma batteritlyp eller en eller en ekvivalent typ som rekommenderas av tillverkaren Kassera anvant betteri enligt fabrikantens instruktion VARNING Felaktigt batteribyte kan medfora fara for explosion Anvand darfor endast samma typ eller likvardig typ enligt apparattillverkarens rekommendation Kassera forbrukade batterier enligt tillverkarens anvisning SPT TANDBERGTOLXY Serial Protocol Translator Installation and Configuration Manual 23 Appendix A 24 SPT TANDBERGTOLXY Serial Protocol Translator Installation and Configuration Manual Warranty Leitch Incorporated Leitch warrants to each original end user purchaser or licensee each a Customer of hardware or software products manufactured by Leitch each a Product or of non warranty repair or other services provided by Leitch Services that each such Product and all such Services will be free from defects in materials and workmanship that adversely affect the Product s performance or the Services intended purpose for a period the Warranty Period of One year for server hardware Products Two years for non server and Desktop hardware Products Ninety days for parts assemblies and su
14. ial Protocol Translator Installation and Configuration Manual 21 Appendix A Do Not Operate in an Explosive Atmosphere To avoid injury or fire hazard do not operate this product in an explosive atmosphere Avoid Exposed Circuitry To avoid injury remove jewelry such as rings watches and other metallic objects Do not touch exposed connections and components when power is present Product Damage Precautions 22 CAUTION Disconnect power from the frame before removing or installing input output modules Removing or installing modules with power applied could cause serious damage to system components Use Proper Power Source Do not operate this product from a power source that supplies more than the specified voltage e Use Proper Voltage Settings Before applying power ensure that the line selector is in the proper position for the power source being used Provide Proper Ventilation To prevent product overheating provide proper ventilation Do Not Operate With Suspected Failures If you suspect there is damage to this product have it inspected by qualified service personnel CAUTION This unit can have more than one power supply cord To de energize the internal circuitry you have to disconnect all power cords ADVARSEL Utstyret kan ha mere ennn en tilf rselsledning For gjore interne deler spennigsl se m alle tilf rselsledningene trekkes ut VARNING Denna apparat har mer n en n tanslutni
15. itch Device ID 07 11 Chapter 4 Reassembling the Unit 12 To avoid damage to the SPT TANDBERGTOLXY circuitry the unit must be reassem bled as shown in Figure 4 3 Note that one of the four standoffs on the underside of the bottom cover has been removed Orient the cover so that this area is positioned directly over U1 If U1 is positioned under an intact standoff the standoff will press against the component and possibly cause damage to the unit Rear Slot Removed Stand off Front Slot Power Control X Y on Leitch X Y Coax Direction gt or 9 pin D RS 232 9600 Baud mini XLR SPT TANDBERGTOLXY V2 11 Connector If changes are made to settings inside of this unit remember to update the label for future reference Figure 4 3 Reassembling the Unit SPT TANDBERGTOLXY Serial Protocol Translator Installation and Configuration Manual Configuring the SPT TANDBERGTOLXY Protocol Notes The SPT TANDBERGTOLXY uses RS 232 protocol to translate Tandberg controller messages into Leitch X Y messages to command devices on the Leitch X Y bus Sim ilarly the SPT TANDBERGTOLXY translates Leitch X Y status and response mes sages into Tandberg messages to alert the Tandberg controller of command responses and changes in status When the SPT TANDBERGTOLXY powers up it requires approximately 45 seconds to update the internal status table During this time the SPT TANDBERGTOLXY
16. n the features and applications for the Leitch SPT TANDBERGTOLXY Serial Protocol Translator It is written for technicians and operators responsible for installation setup and or operation of the product and is useful to operations personnel for purposes of daily operation and reference Writing Conventions This manual has the following conventions Safety messages or other important types of information are separated from regular text via identifying labels or dividing lines Bold text is used to place emphasis on certain words Computer or system information as displayed on a screen user required entries push buttons or keys shown exactly as they appear on the keyboard or unit are in Bold Font Also refer to the symbols and safety conventions listed in the Safety section of this manual Unpacking All SPT TANDBERGTOLXY Serial Protocol Translators have been carefully inspected tested and calibrated before shipment to ensure years of stable and trou ble free service 1 Check equipment for any visible damage that may have occurred during transit Confirm that all items listed on the packing list have been received Contact your Leitch dealer if any item on the packing list is missing Contact the carrier if any item is damaged GT ee SS Remove all packaging material before you install the unit SPT TANDBERGTOLXY Serial Protocol Translator Installation and Configuration Manual 1 Chapter 1 Shipping Leitch
17. ng Samtliga n tkablar m ste bortkopplas f r att g ra de interna kretsarna sp nningsfria SPT TANDBERGTOLXY Serial Protocol Translator Installation and Configuration Manual Safety CAUTION REPLACE WITH SAME TYPE FUSE ATTENTION UTILISER UN FUSIBLE DE RECHANGE DE MEME TYPE FUSE REPLACE WITH SAME TYPE AND RATING OF FUSE CAUTION DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE ATTENTION DEBRANCHER AVANT DE REMPLACER LE FUSIBLE ACHTUNG VOR AUSWECHSELN DER SICHERUNG IST DAS GERAT VOM NETZ ZU TRENNEN CAUTION Disconnect power from the frame before removing or installing input output modules Removing or installing modules with power applied could cause serious damage to system components Use Proper Power Source Do not operate this product from a power source that supplies more than the specified voltage Battery Use Warnings WARNING Replace battery with CR2032 only Use of another battery may present a risk of fire or explosion WARNING Battery may explode if mistreated Do not recharge disassemble or dispose of in fire WARNING Lithium battery Danger of explosion if incorrectly replaced Must only be replaced by a battery of same make and type Used batteries shall be returned to the supplier ADVARSEL Lithiumbatteri Eksplosionsfare ved fejlagtig handtering Udskiftning ma kun ske med batteri af samme fabrikat oq type Lever det brugte batteri tilbage till leverandoren WARNING Danger o
18. ng a reset a delay of approximately 45 seconds will follow During the delay period the unit restatuses and rebuilds internal crosspoint information based on the current Leitch router system status After the delay status information M messages will be sent to the Tandberg controlling device Matrix Size XD001 XDO002 XDO03 XDOO4 Refer to the Sandar Proscan Protocol User Manual for an explanation of Matrix Size messages Linked Level Offset XD005 The Linked Level Offset feature is supported by neither the SPT TANDBERGTOLXY nor Leitch router equipment As such the following static response indicates that there are no linked level offsets XD005 000 000 000 000 000 000 000 000 Host Controller Release Number Messages XR The response message will contain a string similar to SPT Sandar v2 11 Tributary Information XTA Neither the SPT TANDBERGTOLXY nor Leitch router equipment support Tributary Information The response message will always be XTA NONE 16 SPT TANDBERGTOLXY Serial Protocol Translator Installation and Configuration Manual Configuring the SPT TANDBERGTOLXY Reference This documentation used the following reference for implementing the protocol translation User Manual Sandar Prosan Protocol SC2000 Matrix Controller from Release 2 9 991001 TeleCast Norge AS Sandefjord Norway SPT TANDBERGTOLXY Serial Protocol Translator Installation and Configuration Manual Chapter 4 18 SPT TANDBERGTOLXY Serial Pro
19. om Sandar Prosan protocol to Leitch X Y LEITCH a 7 E BEBE BEEBE eee mirct V E kE kE kE HE mEEkEEEE E mrc amp LEITCH Remotely Located Leitch Routing Switchers Leitch X Y Bus Control Panels Figure 2 2 Interfacing to Tandberg Control System 4 SPT TANDBERGTOLXY Serial Protocol Translator Installation and Configuration Manual Chapter 3 Installing the SPT TANDBERGTOLXY Installing the SPT TANDBERGTOLXY The SPT TANDBERGTOLXY is installed in the control line as shown in Figure 3 1 The maximum allowable distance for each segment of the X Y coaxial cable run is 2 000 feet 609 meters The maximum length for each RS 232 segment is 50 feet 15 meters The maximum length for each RS 422 segment is 2 000 feet 609 meters There is no limit to the number of control devices added to the X Y control bus SPT TANDBERGTOLXY Serial Protocol Translator Installation and Configuration Manual 5 Chapter 3 Connecting the SPT TANDBERGTOLXY Figure 3 1 shows how to connect the SPT TANDBERGTOLXY from Tandberg con trollers to Leitch router frames and control panels Figure 3 2 shows connector pin assignments for ports configured for RS 232 or RS 422 Edit controller to router interface software written for Sandar routers Tandberg controller oo C See cable wiring details RS 232 R
20. on 4 5 Transmit Common 6 Transmitted Data Tb 7 Received Data Ra 8 Frame Ground 9 Received Common Received Data Tb Transmitted Data Ra Frame Ground PBPNWAhAANWEO Maximum Cable Length 2 000 feet 610 meters shielded multi pair Figure 3 3 Cable Wiring Details for SPT TANDBERGTOLXY m Interconnect Cable Tandberg Controller DB 9 DB 9 SPT TANDBERGTOLXY DB9 Male Female Female DB 9 Male Receive Data RXD 2 2 Received Data RXD RS 232 Transmit Data TXD 3 3 Transmitted Data TXD Ground GND 5 5 Ground GND 5 Data Terminal Ready DTR 4 Data Set Ready DSR 6 Request to Send RTS 7 Clear to Send CTS 8 Maximum cable length 50 feet 15 24 meters shielded multipair Figure 3 4 Cable Wiring Details for SPT TANDBERGTOLXY to Tandberg Controller 8 SPT TANDBERGTOLXY Serial Protocol Translator Installation and Configuration Manual Chapter 4 Configuring the SPT TANDBERGTOLXY Configuring the SPT TANDBERGTOLXY Note Always update the label on the back of the SPT housing whenever the DIP switch or jumper settings are changed The SPT TANDBERGTOLXY is shipped from the factory preconfigured for use In most cases you will not need to reconfigure the SPT The following parameters how ever you can reconfigure SPT TANDBERGTOLXY Serial Protocol Translator Installation and Configuration Manual Reconfigurable Setting Factory Default Setting RS 232 or RS 4
21. oy Imagine xX COMMUNICATIONS Installation and Configuration Manual SPT SPT TANDBERGTOLXY Serial Protocol Translator Tandberg Controller For Leitch Routers Edition A August 2002 TNDBRGTOLXY MAN Delivering the Moment imaginecommunications com Publication Information 2014 Imagine Communications Corp Proprietary and Confidential Imagine Communications considers this document and its contents to be proprietary and confidential Except for making a reasonable number of copies for your own internal use you may not reproduce this publication or any part thereof in any form by any method for any purpose or in any language other than English without the written consent of Imagine Communications All others uses are illegal This publication is designed to assist in the use of the product as it exists on the date of publication of this manual and may not reflect the product at the current time or an unknown time in the future This pub lication does not in any way warrant description accuracy or guarantee the use for the product to which it refers Imagine Communications reserves the right without notice to make such changes in equipment design specifications components or documentation as progress may warrant to improve the performance of the product Trademarks SPT ADAC ADCOE BOS Broadcast Operating system DigiBus DigiPeek Digital Glue DigiWorks DTV Glue Engineering The Big Picture Event
22. pplies to support hardware Products previously sold to Customers Ninety days for media of software licensed separately from Leitch hardware Products and encoding created by Leitch as physically affixed on or embedded in such media The same period as the hardware Product warranty for media of software licensed as an integral part of any Leitch hardware Product and encoding created by Leitch as physically affixed on or embedded in such media Ninety days for Services Please refer to the current Leitch Limited Warranty Policy for a complete description of the warranty provided including important exclusions and limitations as well as procedures for obtaining warranty service
23. t SW1 Pole 5 The SW1 Pole 5 bit provides a selectable parameter native to Sandar Prosan proto col which allows you to inhibit disconnecting a destination from sources altogether The factory default is to set this bit to the ON position When bit 5 is ON the SPT TANDBERGTOLXY will internally substitute the disconnect code 000 or 00 with the value for Source 1 In this mode a disconnect request will always result in a connection to Source 1 When bit 5 is OFF the SPT TANDBERGTOLXY will make no internal substitutions for the disconnect code the destination will be disconnected from all sources SPT TANDBERGTOLXY Serial Protocol Translator Installation and Configuration Manual 13 Chapter 4 Three Digit Formatting SW1 Pole 6 The SW1 Pole 6 bit provides a selectable parameter native to Sandar Prosan proto col which allows you to specify how many digits 2 or 3 with which values for Matrix and Status Response messages are formatted The factory default is to set this bit to the ON position When bit 6 is ON source and destination values will be formatted with 3 digits for example 001 Here is an example of a Status response message formatted in 3 digit mode SA 001 002 003 004 005 006 007 008 Here is an example of a Matrix message formatted in 3 digit mode M001 001 002 003 004 005 006 007 008 When bit 6 is OFF source and destination values will be formatted with 2 digits for example 01
24. tocol Translator Installation and Configuration Manual Appendix A Safety Carefully observe the safety alert symbols below for dangers warnings and cautions They alert installers and operators of possible dangers or important information con tained in this manual Keep in mind though that warnings alone do not eliminate hazards nor are they a sub stitute for safe operating techniques and proper accident prevention measures IMPORTANT Only qualified personnel should perform service procedures Safety Terms and Symbols in this Manual A DANGER Statements identifying conditions or practices that will result in severe personal injury or loss of life High voltage is present Statements identifying conditions or practices that may result in personal injury or loss of life High voltage is present A CAUTION Statements identifying conditions or practices that can result in damage to the equipment or other property Safety Terms and Symbols on the Product DANGER High voltage and indicates a personal injury hazard immediately AN accessible as one reads the marking WARNING Indicates a personal injury hazard not immediately accessible as one reads the marking SPT TANDBERGTOLXY Serial Protocol Translator Installation and Configuration Manual 19 Appendix A attention and refer to the manual D Protective ground earth terminal i Fuse Replace with same type and rating of fuse Zur Vermeidung von Feuer verw