1. Operating the pump without water for an extended period may damage the pump and cause it to fail Once pumping has completed unplug the pump The pump may become hot during operation Be careful we working near or touching the pump CAUTION Water and electricity do not mix Make sure continuously check that the power connections and cables are not in contact with water Consult an electrician if you have any questions or concern about the electrical circuit or pump operations Copyright Watershed Innovations All rights reserved HydraPump Mini Documentation Rev 2 0 TROUBLESHOOTING Possible Solutions not connected or plug in pump Pump is on but no water is 1 Pump not oiled 1 Oil pump through flowing 2 Inlet hose is too inlet long 2 Shorten the inlet 3 Hoses kinked hose 3 Straighten out the hoses Pump stops with warning No water to pump Check inlet water Pump has supply overheated and Unplug and let the thermal overload pump cool has tripped Straighten out Hoses have become hoses kinked Pump leaks Hose O rings Remove inlet and missing outlet hoses and reinstall CONTACT For additional questions or comments please contact Watershed Innovations at the following Email info hydrabarrier com Phone 1 888 876 4068 9AM to 5PM Pacific CLEANING AND MAINTENANCE BEFORE EACH USE Inspect the general condition of the pump Check for loose screws misalignment or binding of moving parts cr
2. HydraPump Mint Owner s Guide Copyright Watershed Innovations All rights reserved HydraPump Mini Documentation Rev 2 0 USAGE GUIDE NOTE This Water Pump has been designed to operate on 110 120 Volt 60 Hz exclusively Using any other voltage or Hz adversely affects performance IMPORTANT Keep this guide for future reference CAUTION Be sure to review SAFETY INSTRUCTIONS FIRST PERTAINING TOA RISK OF FIRE ELECTRICAL SHOCK OR INJURY TO PERSONS before using the pump TOOLS AND MATERIALS YOU MAY NEED e Absorbent cloth or HydraTowel to for clean up and maintenance e Standard hose for the outlet a small hose is provided for the inlet e PTFE tape sometimes this is referred to as plumber s tape PACAKAGE CONTENTS 1 piece HydraPump Mini 1 piece Plastic Inlet strainer 1 piece Short inlet hose 1 piece repair and maintenance kit 1 Tablespoon Food grade vegetable oil Copyright Watershed Innovations All rights reserved HydraPump Mini Documentation Rev 2 0 SITE PREPARATION Make sure your work area where you intend to use the pump is clear of clutter and well lit Also ensure that the pump is in a location that it will not be submerged or in contact with external water The pump is designed to pump fresh water so please make sure that the water source does not contain large bits of debris IMPORTANT SAFETY INSTRUCTIONS INSTRUCTIONS PERTAINING TO A RISK OF F
3. IRE ELECTRIC SHOCK OR INJURY TO PERSONS SAVE THESE INSTRUCTIONS WARNING When using electrical pumps basic precautions should always be followed including the following 1 Read all instructions before using the pump 2 To reduce the risk of injury close supervision is recommended at all times that the pump is in operation 3 Do not put fingers or hands into a water pump inlet our outlet when operating 4 Unplug the power before attempting to move the pump 5 For proper grounding instructions see the ELECTRICAL CONNECTION portion of this manual Copyright Watershed Innovations All rights reserved HydraPump Mini Documentation Rev 2 0 WATER AND ELECTRICAL CONNECTIONS HOSE CONNECTIONS Connect a standard garden hose to the both the inlet and outlet of the pump If using another hose than the provided short hose for the inlet connect then ensure that the supplied inlet hose is less than 25 long and less than 10 above the water source Note Keep the hoses as straight as possible and this will improve the efficiency of the pump GROUNDING INSTRUCTIONS THE WATER PUMP IS EQUIPPED WITH A GROUNDED PLUG IN POWER CORD This pump must be grounded In the event of a malfunction or breakdown grounding provides a path of least resistance for electric current to reduce the risk of electric shock This pump is equipped with a cord having an equipment grounding conductor and a grounding plug The plug must be plugged into
4. acked or broken parts damaged electrical wiring and any other condition that may affect its safe operation AFTER USE Unplug the pump and let cool as it may be hot from operating Remove the hose connections Carefully tilt and drain all excess water from inside the pump Lastly clean external surfaces of the pump with clean cloth or sponge Copyright Watershed Innovations All rights reserved HydraPump Mini Documentation Rev 2 0 Watershed atersneo Cinno ons vati SPECIFICATIONS Head Ft e 1 10 HP Single Phase 120V 60Hz 2 3A e 3 4 Chrome plated bronze suction discharge connectors e Easy carry handle for portability e 18AWG power cord 6 long e Flow please see chart below 50 1 0 40 30 20 10 0 0 50 100 150 200 250 300 350 Flow GPH Copyright Watershed Innovations All rights reserved HydraPump Mini Documentation Rev 2 0 REFERENCE PARTS LIST Parts list reference 2 Endcover _ _ _ 10 Oilslinger 0 Copyright Watershed Innovations All rights reserved HydraPump Mini Documentation Rev 2 0
5. an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances ELECTRICAL CONNECTIONS A Connect pump to 110 120 Volt 60 Hz AC current only B Use a three prong plug see figure below CS 8 Prong Plug and Outlet CAUTION Do not allow the pump electrical cord or electrical outlet to come into contact with water This may result in serious injury If unsure of how to install or use this pump consult a licensed electrician Copyright Watershed Innovations All rights reserved HydraPump Mini Documentation Rev 2 0 OPERATING INSTRUCTIONS PUMP PREPARATION Before operating the pump needs to be oiled Pour tablespoon of food grade vegetable oil into the inlet of the pump This should provide the necessary lubrication to the impeller OPERATION The following are the steps for operation 1 2 PL After oiling the pump make sure inlet and outlet hose are connected firmly attached Verify that the pump is placed in a safe area and will not be submerged or come in contact with a water source Check that the inlet hose is submerged connected to a water source Make sure the end of the outlet hose is connected correctly Carefully plug the pump into a 3 wire 120 Volt 60 Hz grounded A C Outlet to begin operation The pump is self priming and water should begin to flow 30 seconds or less a Ifwater does not flow unplug the pump and check the connection and setup b