1. Continuity Testing Continuity is indicated at less than 270kQ of resistance coNT ADD A GFCI Testing Ay Check the GFCI Receptacle user manual for more information Always contact a qualified electrician to resolve wiring problems AX Operate the Push Button on the GFCI Receptacle If the GFCI circuit does not trip the receptacle is not operating properly To test the functionality of a Ground Fault Circuit Interrupter receptacle apply leads to the hot and ground terminals for 7 seconds e lf the GFCI receptacle is wired properly power to the circuit will go out and the ET200 will stop indicating voltage e lf the GFCI receptacle is wired improperly power to the circuit will remain and the ET200 will continue to indicate voltage To resolve an issue contact a qualified electrician Battery Replacement Batteries are not required for visual voltage indication 1 Remove test leads from voltage source 2 Unscrew battery cover and replace 3xAAA batteries Test Equipment Depot 1 800 517 8431 b 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 WARRANTY This product is warranted to be free from defects in materials and workmanship for a period of two years from the date of purchase During this warranty period Klein Tools has the option to repair or replace or refund the purchase price of any unit which fails to conform to this warranty under norm
2. Tools logo to toggle the worklight on and off Ghost Voltages The approximate input resistance of 15kQ will reduce the possibility of false readings due to ghost voltages on de energized lines Lead Spacing Molded lead holders on the back of the ET200 are spaced correctly to test tamper resistant outlets Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com OPERATING INSTRUCTIONS Measuring Voltages Ax Time spent operational at voltages above 277V must be less than 60 seconds with a cool off time of at least 5 minutes Tester will turn on automatically when voltage is applied AC Voltage Measurement DC Voltage Measurement
3. al use and service This warranty does not cover damage which occurs in shipment or failure which results from alteration tampering accident misuse abuse neglect or improper maintenance Batteries and damage resulting from failed batteries are not covered by warranty A purchase receipt or other proof of original purchase date will be required before warranty repairs will be rendered Any implied warranties including but not limited to implied warranties of merchantability and fitness for a particular purpose are limited to the express warranty Klein Tools shall not be liable for loss of use of the instrument or other incidental or consequential damages expenses or economic loss or for any claim or claims for such damage expenses or economic loss Some states or countries laws vary so the above limitations or exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state If your Klein product requires repair or for information on how to exercise your rights under the terms of this warranty please contact Klein Tools at 1 800 553 4676 CLEANING Clean the instrument by using a damp cloth Do not use abrasive cleaners or solvents STORAGE Remove the batteries when instrument is not in use for a prolonged period of time Do not expose to high temperatures or humidity After a period of storage in extreme conditions exceeding the limits mentioned in
4. ity 0 C to 30 C 32 F to 86 F 90 30 C to 40 C 86 F to 104 F 75 40 C to 55 C 104 F to 131 F 45 Operating Temperature 0 C to 55 C 32 F to 131 F Storage Temperature 0 C to 55 C 32 F to 131 F Dimensions 7 375 x 2 375 x 1 25 Weight 8 10z Safety CSA C22 2 1010 1 IEC 61010 1 Pollution Degree II CAT Rating CAT IV 600V CAT III 1000V A WARNINGS Failure to observe these warnings can result in severe injury or death Before each use verify meter operation by measuring a known voltage or current Never use the meter on a circuit with voltages that exceed the category based rating of this meter Do not use the meter during electrical storms or in wet weather Do not use the meter or test leads if they appear to be damaged Ensure meter leads are fully seated and keep fingers away from the metal probe contacts when making measurements Do not open the meter to replace batteries while the probes are connected to a voltage source Use caution when working with voltages above 60V DC or 25V AC RMS Such voltages pose a shock hazard Shut off and lock out power before testing continuity Always adhere to local and national safety codes Use individual protective equipment to prevent shock and arc blast injury where hazardous live conductors are exposed SYMBOLS f Positive DC Voltage A Warning or Caution Negative DC Voltage A Dangerous levels AC Voltage mE Double Insulated Class Il L Ear
5. th Ground ETL Certification LISTED This product has been tested to the requirements of CAN CSA C22 2 No 61010 1 second edition including Amendment 1 or a later version of the same standard incorporating the same level of testing requirements CAT Ill CAT IV Designed for transient protection on outdoor measurements taken at the primary supply voltage Designed for transient protection on indoor measurements at installations connected directly to the primary source Examples source Examples include outdoor include distribution panels and overhead or underground utility lighting systems in large buildings service and electricity meter FEATURE DETAILS Indicators Lights e LEDs light up numerical voltage level indicators as well as AC and DC or DC indicators e Continuity LED will light up on detection e Voltage detection will function without batteries installed Vibration e Instrument will vibrate in the presence of voltage measurements greater than 48V e Vibration will function only with batteries installed Sound e Instrument will emit a tone in the presence of voltage measurements greater than 48V e Instrument will emit a tone on detection of continuity e Sound will function only with batteries installed Accuracy Accuracy of indicator lights is 70 to 100 of the voltage displayed to account for normal variations in supply voltage Worklight Press the light bulb button above the Klein
6. the Specifications section allow the instrument to return to normal operating conditions before using it DISPOSAL RECYCLE Caution This symbol indicates that equipment and its accessories Dz shall be subject to a separate collection and correct disposal 139575T instruction Manual ENGLISH Yy C A KLEIN TOOLS ET200 VOLTAGE TESTER 600V CAT IV g 1000V CAT III Di aja be O Ao e AC DC VOLTAGE TO 600V CONTINUITY FUNCTION WORKLIGHT LIGHT VIBRATION SOUND INDICATORS CAT IV 600V SAFETY RATING MODERN SOLID STATE DESIGN sWTERTE W C LISTED ia a KLEIN TOOLS www kleintools com Since 1857 For Professionals ET200 Instruction Manual GENERAL SPECIFICATIONS The Klein Tools ET200 is a solid state electrical tester It measures AC DC voltage tests continuity and features a bright LED worklight To ensure safe operation and service of the tester follow these instructions Voltage Level Indicators 12 24 48 120 208 240 277 480 600 Voltage Type Indicators AC DC Positive DC Negative AC Frequency 45Hz to 66Hz Maximum Voltage To Earth Ground 600V RMS Maximum Measurable Voltage 600V RMS displayed by LEDs Input Impedance 15kQ on connection up to 150kQ steady state Continuity lt 270kO Usage Duty Cycle Above 277V 1 minute on 5 minutes off Accuracy 70 to 100 of indicated voltage Battery Type 3 x AAA Operating Altitude 2000m Relative Humid