1. Connecting Readers with Touch Memorv Output Interface Connecting Readers with Wiegand Output Interface Connecting an Arming Request Button Optional sse Getting Started a ERE DE lain ia a B Paanan a paaa a aparana paaa ai S2000 KDL Address Space Allocation it ob Wa it sia Programming Addresses of Devices Connected to the Pooling Loop Programming Changing Device Loop Numbers by Network Controller Tools Programming Address System of the S2000 KDL by Means of UProg UProg Interface Work Settings of the Controller Network Settings of the S2000 KDL Setting Operating Parameters of the S2000 KDL Programming Reader Parameters Working with Addressable Devices Connected to the Polling Loop Registering Addressable Devices Connected to the Polling Loop Programming Loop Addresses of Addressable Devices Requesting Parameters of Addressable Devices Programming Input Addressable Zones of the S2000 KDL Setting the Descriptors of Input Addressable Zones Linking Inputs of the Polling Loop with its Outputs for Local Control Copying Settings of Input Addressable Zones Programming Addressable Outputs of the S2000 KDL Programming Outputs for Remote Control Programming Outputs for Local Control Programming Access Groups Programming Keys Add Edit a Key Delete the Key Managing the List of Keys Save Results Maintenance co a Mud NE Nis We gj R
2. S2000 VT 15 Humiditv Measurement LEM Ex rev 2 www bolid com 2 Combined Fire for interfacing fire detectors or 5 Intrusion With Tamper Check for intrusion detectors with transferring messages about opening closing the detector enclosure or 7 Entrance for intrusion detectors operating with an entrv delav or 11 Panic to receive attack messages without turning alarm equipment on or 6 Auxiliary for auxiliary zones from which only signal about break ing recovering are expected 92 S2000 KDL Programming Auto Rearming Double left click on the field of this option for programmed zone if the zone should be automat ically switched from the Arming Failed status to the Armed status on zone s being recovered Auto Arming After Alarm Double left click on the field of this option for programmed zone if the zone should be automat icallv switched from the Intrusion Alarm Fire Alarm or Fire Prealarm status on broken zone s being recovered this recovering lasting for a time given bv Recoverv Time option Disarmed Zone Monitoring Set this option on bv double left clicking for intrusion protection zones if changing their status es must be monitored even if the zones are disarmed In such case in state of breaking and recovering zones the S2000 KDL will generate messages Not Ready To Arm and Ready To Arm correspondently The zone is considered to be recovered if it is being in norm for a time equal to Recovery Time
3. Add Key The tool adds a new descriptor to the list of keys the same can be done by pressing ns Delete Restore Key This tool deletes and restores keys from the key list the same can be done by pressing Del It marks a key as deleted but the key is not physically cleared from the controller memory and can be restored see below www bolid com 106 S2000 KDL Programmin 2 Find Key Duplicates This tool enables finding descriptors of all the keys that have the same code Clear Keys Physically deletes all keys from the S2000 KDL memory x Defragment Key Memory The tool defragments the key area of the controller memory by clearing the keys marked as deleted followed by rearranging the key order in the list During defragmentation process the keys marked as deleted are replaced with the legal keys so after the defragmentation the numbers of the key descriptors are varied Show Deleted Keys This switch defines whether the keys marked as deleted are visi ble in the key list or hidden If the switch is on the button is sunken the keys marked as deleted are displayed in grey color and can be restored by pressing Delete Restore Key button or lt Del gt button If the switch is off only active keys are shown in the list Q Find Key Finds a key descriptor by the given code of the key The UProg exe provides adding keys to the S20000 KDL memory as well as deleting them and edit ing their
4. Executive Program 10 Alarm Output 1 The program is suitable when the relevant output is used to transmit intrusion alarms to an Alarm Receiving Center Alarms are output on relav contacts relav contacts are open just after occurring alarms of any types Alarms are reset from the relay only after arming all the linked zones Executive Program 11 Discharge Executive Program 33 Discharge 1 Executive Program 34 Discharge A Executive Program 35 Discharge 1A Programs of the Discharge familv are used to generate a command to release extinguish ing agent in case of a fire Usuallv a fixed fire extinguishing system can be started only after receiving responses from detectors in two independent fire protection zones Also to prevent spreading of an extinguishing agent gas or powder outside the premis es a fixed fire extinguishing system can be started only if all doors to the room are closed To monitor door positions zones of Auxiliary type zones of the Type 6 are used When such a zone is broken the door is open it enters the Auxiliary Zone Alarm status while upon restoring the normal status the door has been closed the auxiliary zone automati www bolid com 44 S2000 KDL Operation Principles callv recovers its status after elapsing the time defined bv the Recoverv Time parameter of the Auxiliarv zone see Section Zone s Configuration Parameters of this Manual To realize discharge tactics said above vou should organiz
5. INTRUSION ALARM The addressable detector has responded with an alarm for exam ple breaking a glass has detected or infrared field has been vio lated or The contacts of the S2000 SMK has been open or The addressable device has failed provided that the zone was armed or The addressable input module has been in one of the statuses shown in Table 2 Zone Tvpe 5 Intrusion with Tamper Monitoring A Zone of the Type 5 defines the tactics of monitoring addressable devices which provides not only generating intrusion alarms but also responding with special signals when their enclosure is open The following addressable devices can be connected to zones of the Type 5 a S2000 ST addressable glass break detectors or b S2000 IK addressable passive infrared motion detectors or c S2000 PIK addressable ceiling mount motion detectors or d S2000 MW addressable microwave intrusion detectors or e S2000 STIK addressable combined motion and glass break detector or f S2000 PIK ST addressable combined ceiling mount motion and glass break detectors or g S2000 SHIK addressable curtain PIR motion detectors or h S2000 V addressable shock detectors or i S2000 SMK addressable magnetic contacts or j S2000 SMK Estet addressable magnetic contacts for metal doors or k S2000 KT addressable panic buttons or I S2000 AR1 S2000 AR2 and S2000 AR8 addressable input modules or m LEM Ex rev 2 intrinsic
6. perature Increased Threshold predetermined for the zone TEMPERATURE NORM The measured temperature is between values of Temperature Decreased Threshold and Temperature Increased Thresh old predetermined for the zone TROUBLE The device fails to measure temperature The following configuration parameters are to be programmed for a zone of the Type 10 see also Table 1 Temperature Increased Threshold the value of temperature in degrees Centigrade at the location point of the device for the zone to be considered in the Temperature High status Temperature Decreased Threshold the value of temperature in degrees Centigrade at the location point of the device for the zone to be considered in the Temperature Low status 31 www bolid com SEGURITV SVSTEMS Orion ISS Arming Delav for a Thermostatic zone defines the time in seconds that should pass between control e0 0 ler s receiving an Arm command and starting requesting temperature measurements for the zone DO NOT confuse the temperature increased decreased thresholds defined for the Thermostatic zone and the same thresholds defined for addressable outputs of the S2000 KDL Temperature value s being out of the range programmed for a Thermostatic zone causes the S2000 KDL to switch the zone to the Temperature High Temperature Low status and to transmit the relevant message to the network controller If on the contrarv measured temperature values are out of the ran
7. Never Disarmed Set this parameter on by double left click for fire detection zones of the Tvpes 1 and 3 and for Panic of the Types 11 to avoid their accidental disarming In such case arm and disarm commands for these zones will be ignored Upon receiving a disarm command for the zone which Never Disarm parameter is set on the zone enters either in Armed status if it was in norm before or otherwise the controller will generate a message corresponding the current zone status Arm Disarm by Group Set the option on by double left clicking on all the zones which will be armed or disarmed to gether on controller s receiving the relevant command sent by the network controller This pa rameter is valid only for zones which are assigned to some Device Types in the network con troller s database Arming Delay Set the time in seconds for which the controller will delay trying to arm the zone A non zero Arming Delay is usually used for intrusion detection zones for example in order a user having armed the zone can leave the premises for some time without generating alarms To set a time of Arming Delay double click by left mouse button on the field and type a proper value or select the value by arrow buttons Recovery Time This option defines the time in seconds on having elapsed which the zone entered from one of the statuses Intrusion Alarm Fire Alarm Fire Prealarm Not Ready To Arm or Ready To Arm is considered as recovered To
8. To set change the value double click by the left mouse button on the field of the parameter and type a proper value or select the value by arrow buttons Humidity Increased Threshold This parameter is to be programmed for zones of the Type 15 and represents the value of relative humidity in measured by the relevant sensor S2000 VT on having reached which the S2000 KDL generates the message High Level for this zone By default the threshold is 70 and can be changed in the range of 0 to 10096 To set or change the value of this threshold double click by the left mouse button on its box and type a required value or select the value by arrow buttons Humidity Decreased Threshold This parameter is to be programmed for zones of the Type 15 and represents the value of relative humidity in measured by the relevant sensor S2000 VT on having dropped to which the S2000 KDL generates the message Low Level for this zone By default the threshold is 6096 and can be changed in the range of 096 to 10096 To set or change the value of this threshold double click by the left mouse button on its box and type a required value or select the value by arrow buttons DO NOT confuse the increased decreased thresholds defined for Humidity Measure ment zones of the polling loop with the same thresholds defined for its relay outputs Linking Inputs of the Polling Loop with its Outputs for Local Control If events in some zone zones of the polli
9. row buttons at the right part of the relevant field The maximum activation time for a relay is equal to 65 535 intervals 0 125 s each 8192 s in total By default relays are activated for a minute 60 seconds www bolid com 100 S2000 KDL Programming For programs 36 and 37 this parameter defines the time interval for which the output will be activated in a discrete mode see description of executive programs in the Section Local Ex ecutive Programs for Controlling Polling Loop Outputs of this Manual In case of centralized control this setting is ignored Activation Delav For executive programs 1 8 11 12 17 35 this parameter defines the time in which the given executive program will be run after S2000 KDL s receiving a message about chang ing status of a zone linked with the output The maximum delay is 65535 intervals of 0 125 s 8192 s each By default an output is acti vated without delay with the delay equal to 0 seconds For programs 36 and 37 this setting has special meaning regulating gaps between succes sive turnings the output on see the description of executive programs in Section Local Execu tive Programs for Controlling Polling Loop Outputs of this Manual In case of centralized control this setting is ignored Notify on Changing Relay Statuses The parameter is set for each output individually If the parameter is set equal to Yes then a change of the status of the programmed output will
10. 1 to 127 If the type of a connected addressable device doesn t match the pre programmed type of this one or the type of the programmed zone the programmed monitoring tactics doesn t match the de vice type the addressable zone is assigned to the Zone Configuration Error status and the relevant message is transmitted over the RS 485 interface In case of Quiescent Poll regardless of the zone status the controller inspects connectivity and sta tuses of those addressable devices which are currently connected to the S2000 KDL Also the con troller periodically searches connected devices at vacant addresses searching devices at the ad dresses for which addressable device s types are programmed in the console configuration being of higher priority than at the addresses for which device types are not programmed Output circuits of the polling loop are implemented as two output branches PL1 and PL2 That pro vides wiring any topology of the polling loop such as a bus a tree a ring or mixed The ring topology provides detecting failures of the polling loop In case of polling loop s being open the controller generates 2WIRE 1 LOST and or 2WIRE 2 LOST message For zones for which communications between its related addressable devices and one of the polling loop outputs is lost the relevant statuses will be assigned After reconnecting addressable devices with the controller at the PL1 port and or the PL2 port 2WIRE 1 RST and or 2WIRE 2
11. Change Device Address in the menu of the UProg The network address of the S2000 KDL can also be programmed or changed by means of the network controller as described in its Manual The Set Response Pause parameter allows using the controller within systems with complicated net work configurations where retranslating data can be delaved in radio relav fiber and etc communication systems This pause introduces a permissible time delay for S2000 KDL re sponses to requests from the network controller To set or change Set Response Pause select the command Device Set Hesponse Pause in the menu of the UProg By default the value of the response pause is equal to 1 5 millisec onds If necessary this value can be increased up to 500 milliseconds Setting Operating Parameters of the S2000 KDL Operating parameters of the S2000 KDL and the reader connected to the controller are programmed on the Device tab of the UProg see Figure 13 Night to Day Threshold Day to Night Threshold This option describes dividing process of monitoring analogue addressable smoke detectors zones of the Type 8 to Night and Day operating modes For Dav time zone to avoid false alarms caused by dust smoke etc you can program higher thresholds for detectors to re sponse with alarms then for the Night time zone To define Day and Night modes select or type to the relevant fields the values of time thresh 81 www bolid com SECURITV SVSTEMS Orion I
12. Control parameter programmed for the polling loop zone the addressable device is as signed to see Section nput Zones of the Polling Loop of this Manual In the Controlled by the S2000 KDL mode the behavior of addressable device LEDs are defined by the status of the zone assigned to the addressable device as shown in Table 9 The tactics of LED lighting depending on zone statuses upon is shown as a blink mask which is repeated with a period of 4 s Each position in a blink mask corresponds to 0 5 s A filled circle corresponds to indicator lighting during half a second while an empty circle means that the LED is off for half a second Table 9 Indication of Addressable Devices Under Control of the S2000 KDL Zone Status Description Blink Mask Norm For all types of zones 0000000 Intrusion Alarm For zones of the Types 4 5 7 and 11 000000 Fire Prealarm For the Fire Prealarm mode eeeooooo For zones of the Types 2 and zones of DIP 34A connection of 1 and 8 types eeoooooo Fire Alarm For zones of the Types 1 3 8 and 9 g Lit steadv excluding zones of DIP 34A connection Trouble1 Measuring channel has failed so Trouble2 Open or short circuit failure eooeeooo High contamination level for zones of the Contaminated 00000000 Types 1 and 8 Parameter Error Error of zone parameters eoooeooo Arming Failed Arming the zone failed 00000000 53 www bolid com SEGURITV SV
13. ON RELAV SWITCHES RELAV OFF USER S CODE ENTR ACCESS DENIED ILLEGAL CODE ERR IN RESPONSE COMM UNSTABLE 2WIRE 1 LOST 2WIRE 2 LOST 2WIRE 1 RST 2WIRE 2 RST 2WIRE LINE SHORT 2WIRE LINE TRBL 2WIRE LINE RST DEVICE RESTART POWER FAILED Communications between the S2000 KDL and the addressable re lay module has been restored Not supported yet A user has presented an electronic key to the reader of the S2000 KDL A user has presented a registered electronic key which however is being disabled at the moment A user has presented an electronic key which is not enrolled in the memory of the network controller Or in case of loss of communica tions between the network controller and the S2000 KDL a user has presented an electronic key which is not enrolled in the memory of the S2000 KDL An error has been found in the addressable device s response Unstable communications between the addressable device and the S2000 KDL Communications between the addressable device and the PLI ter minals of the controller has been lost This message is not support ed yet Communications between the addressable device and the PL2 ter minals of the controller has been lost This message is not support ed yet Communications between the addressable device and the PL1 ter minals of the controller has been restored This message is not supported yet Communications between the addressable device and the PL2
14. RST messages will be generated To locate short circuit failures BRIZ short circuit isolators are to be brought to the polling loop Also these isolators are used to make branches in the polling loop and to avoid effects of failures in one www bolid com 16 S2000 KDL Operation Principles loop segments to another segment When a short circuit failure has happened failed part of the loop between two BRIZ es in case of ring topology of behind the relevant BRIZ is disabled with the con troller generating 2WIRE 1 LOST and or 2WIRE 1 LOST messages On recovering normal polling loop conditions the BRIZ automatically restores connection between isolated segments and the con troller generates 2WIRE 1 RST and or 2WIRE 2 RST messages If communications with an addressable device is lost for both polling loop outputs the zone is switched to the Disconnected status In such case the controller remembers the previous status of the zone and having found the device with the stored address at one of the polling loop outputs when the device is connected again the status of the zone will be restored For example if a zone had Armed status before losing then after restoring communications the zone will also have Armed status 17 www bolid com SEGURITV SVSTEMS Orion ISS INPUT ZONES OF THE POLLING LOOP The input zones of the S2000 KDL are the points of connecting initiating addressable devices to the polling loop Up to 127 various responden
15. SEGURITV SVSTEMS Orion ISS www bolid com 62 S2000 KDL Installation INSTALLATION 63 www bolid com SEGURITV SVSTEMS Orion ISS STANDARD DELIVERV Find the following unpacking the S2000 KDL gt S2000 KDL controller CD disk with this User s Manual gt DIN 7982 Flat Head Tapping Screw with Cross Drive 2 2x6 5 gt Three Wood Screws gt Three Wall Plugs SAFETY PRECAUTIONS There are no potential hazard circuits within the controller Do SHUT OFF the controller power before mounting wiring or maintaining the S2000 KDL Mounting and maintenance the controller must be implemented by qualified engineers S2000 KDL MOUNTING The controller can be attached behind a suspended ceiling on a wall or any other structures in prem ises protected against atmospheric fallouts mechanical damage and unauthorized access The S2000 KDL is composed from a base with attached PCB cm Figure 2 and the top cover Figure 3 shows overall and mounting dimensions of the S2000 KDL To install the S2000 KDL secure its base on a DIN rail or hang this one on a vertical surface In the latter case drill three holes on the wall as shown in the layout see Figure 3 then hang the S2000 KDL base on the two wood screw provided and finally lock its position with the third wood screw pro vided Once the S2000 KDL base is attached to the wall or a DIN rail close the S2000 KDL top cover and tighten the DIN 7982 tapping screw provided If necessar
16. SYSTEMS Addressable Device Orion ISS Zone Type to Be Programmed IPR 513 3A 3 Heat Fire S2000 AR1 3 Heat Fire for interfacing fire detectors or 6 Auxiliary for auxiliary zones from which only signal about break ing recovering are expected or 4 Intrusion to connect intrusion detectors or 5 Intrusion With Tamper Check if you want to take notice of tamper ing the intruder detector s enclosure or 7 Entrance if you want to realize the mode of operating the intrusion detector with delaving alarms or 11 Panic to receive attack messages without turning alarm equip ment on S2000 AR2 2 Combined Fire for interfacing fire detectors or 6 Auxiliarv for auxiliarv zones from which oniv signal about break ing recovering are expected or 4 Intrusion for interfacing intrusion detectors or 7 Entrance if vou want to realize the mode of operating the intrusion detector with delaving alarms or 11 Panic to receive attack messages without turning alarm equip ment on S2000 AR8 2 Combined Fire for interfacing fire detectors or 4 Intrusion for interfacing intrusion detectors or 5 Intrusion With Tamper Check if vou want to take notice of tamper ing the intruder detector s enclosure or 7 Entrance if vou want to realize the mode of operating the intrusion detector with delaving alarms or 11 Panic to receive attack messages without turning alarm equip menton S2000 ASR2 13 Counting
17. Threshold and Fire Sensitivitv Threshold are to be programmed to issue fire prealarms and fire alarms respectivelv These thresholds are programmed for Dav Mode and Night Mode separatelv Periodicallv the S2000 KDL requests the values of contamination within smoke chamber of the detec tor and compares these values with the Contamination Thresholds programmed for each zone of the Type 8 individually Available statuses of a zone of the Type 8 are the following ARMED The zone is entirely monitored no preprogrammed thresholds Fire Sen sitivity Threshold Prealarm Sensitivity Threshold or Contamination Threshold are exceeded DISARMED The zone is monitored only for troubles and exceeding the Contamina tion Threshold ARMING DELAY Arming the zone is being delayed ARMING FAILED While the zone is being armed one or more of its programmed thresholds for the current time mode Fire Sensitivity Threshold Prealarm Sensi tivity Threshold or Contamination Threshold is exceeded or a trouble has occurred 29 www bolid com SECURITY SYSTEMS FIRE PREALARM FIRE ALARM TROUBLE SERVICE REQUIRED Orion ISS The smoke concentration measured by the detector has exceeded the Prealarm Sensitivitv Threshold preprogrammed for the zone for the cur rent time of the day mode Night Day The smoke concentration measured by the detector has exceeded the Fire Sensitivity Threshold preprogrammed for the zone for the current time of the
18. annually The inspection algorithm shall include Visual checking the S2000 KDL against contamination and mechanical damage 9 Verifying the S2000 KDL for secure mounting and wire connection conditions G Inspection of the controller operability in accordance with the techniques shown below The controller must be tested under the following ambient conditions Temperature 25 C 10 C Relative humidity 45 80 Atmospheric pressure 630 mm Hg 800 mm Hg b Power off the controller before connecting and disconnecting wires Self Diagnostic Routine To start self diagnostic remove the S2000 KDL cover and press the tamper switch see Figure 2 three times shortly and then a time more long The more long means keeping the tamper switch held down for at least 1 5 s while shortly means keeping the tamper switch held down for 0 1 s 0 5 s The pauses between pressings should be no less than 0 1 s and no more than 0 5 s If the controller is operable all the LEDs READY RS 485 and LOOP shall flash with long pauses one by one The controllers not meeting the requirements said above makes it possible to raise a claim to the vendor 115 www bolid com SEGURITV SVSTEMS Orion ISS www bolid com 116 BOLID ONE VEAR LIMITED WARRANTV Bolid Company and its divisions and subsidiaries Seller 4 Pionerskava Str Korolev 141070 Moscow Re gion Russia warrants its security equipment the product to be free from defe
19. be controlled locally it is necessary to link each output to those input zones of the polling loop which changing of status should cause activating the executive program given for this output if such links were not given while programming input zones on the Zones tab see Section Programming Input Addressable Zones of the S2000 KDL of this Manual To assign the output to input addressable zones of the polling loop select the column with the num ber of this output and left click the fields of those zones at the bottom which will be linked to this out put Then give the following parameters for each output Executive Program This setting defines the tactics of local control for the output depending on statuses of zones assigned to the output as mentioned above as well as the initial status of the output after turn ing the controller power on To give an executive program for an addressable output double click on the field of this pa rameter for the output and select the required program from the dropdown list Table 4 on the page 40 of this Manual presents the list of all executive programs available for the S2000 KDL By default all relay outputs of the S2000 KDL are assigned to the executive program 0 He mote Control Relay Activation Time This option defines the time for which the output will be turned on or off in case of executing a programmed local program which implies limited executive time Select the proper value by ar
20. cause S2000 KDL generating the relevant message followed by sending the network con troller the message along with the loop address of the output By default the parameter is not set equal to No The following parameters are programmed only for outputs controlled by executive programs 36 and 37 And Or Logic By default the output operated by one of the executive programs 36 or 37 and assigned with several Thermostatic Humidity Measurement zones is activated if at least one of the linked of the Type 10 15 has entered the specified status the value is OR O If the value AND 1 is set for this parameter the output will be activated if only all the linked zones have entered the specified status Temperature Increased Threshold This parameter defines the value of the ambient temperature measured by the temperature sensor of an addressable device in the assigned addressable zone of the S2000 KDL which receiving will cause turning on the output for the program 36 and turning off the output for the program 37 The Temperature Increased Threshold is programmed for each output individually in the range from 55 C to 125 C By default its value is equal to 22 C 101 www bolid com SECURITV SVSTEMS Orion ISS Temperature Decreased Threshold This setting defines the value of ambient temperature measured by the temperature sensor of an addressable device in the assigned addressable zone of the S2000 KDL which rece
21. controller the output can be switched on off or being switched on off alternately If an addressable output is to be controlled locally it shall be assigned to en executive program and linked with those input zones of the S2000 KDL which status changes will run the program Also an activation time and activation delay can be defined for this output see Section Programming Ad dressable Outputs of the S2000 KDL of this Manual Local control of the addressable outputs of the polling loop is of higher priority than cen e tralized remote control That is if there is a link between the output and an S2000 KDL input zone in the controller configuration any remote control commands received over the RS 485 interface for this output will be ignored www bolid com 38 S2000 KDL Operation Principles Configuration Parameters of Addressable Outputs Table 3 shows the configuration parameters of the S2000 KDL which can be defined for an address able output Table 3 Parameters of the Addressable Outputs ER Factory Executive Program Defines the tactics of controlling the addressable output as well as the initial relay on off condition 0 37 Table 4 describes all the available programs Relay Activation Time Defines the time interval which the relay will be switched on off for if the assigned executive program implies time limitation O s to 8192s 2 h 16 min 32 s in increments of 0 125 s Act
22. created in the UProg The newly created or revised configuration can be Loaded to the controller memory or Device gt Write Configuration to This Device Loaded to the memory of another Device Write Configuration to Another Device connected controller with specified network address Saved to a file of the internal UProg Ho lt F2 gt or File gt Save Configuration to File format with the cnu extension Written as a text to an MS Word file 50 File gt Export Configuration to MS Word www bolid com 80 S2000 KDL Programming Work Settings of the Controller The work settings of the S2000 KDL include the network settings of the controller as well as settings of its operating parameters Network Settings of the S2000 KDL The network settings of the S2000 KDL include a network address of the S2000 KDL over the RS 485 interface and the Set Response Pause option The network address of the controller over the RS 485 interface is stored in its non volatile memory and designed to identifv the controller uniquely within an Orion system The S2000 KDL sends messages and receives commands from the network controller only at the address specified bv this parameter The network address must be unique for each Orion svstem device and can have a value in the range 1 to 127 Upon delivering the controller is assigned to the address of 127 To program or change the network address of the S2000 KDL select the command Device
23. its Zone Type all monitoring tactics supported be the S2000 KDL as well as appropriate zone statuses will be considered below in this Section and The current monitoring status of the zone whether the zone is armed or disarmed Having assigned statuses to zones the S2000 KDL Automatically transfers changed zone statuses over the RS 485 interface and If preprogrammed in its local configuration controls its executive outputs and Returns current zone statuses if requested locally by light indicator and sounder of the reader connected to the S2000 KDL www bolid com 18 S2000 KDL Operation Principles Zone s Configuration Parameters Table 1 shows the list of configuration parameters that can be programmed for the S2000 KDL to de fine various tactics of operating input zones of the polling loop Zone Tvpe Table 1 Parameters of Input Addressable Zones of the S2000 KDL M Factory Defines monitoring tactics for a zone and a range of connectable addressa ble devices intrusion or fire equipment tempera ture or smoke detector etc 1 11 13 15 see below Auto Rearming Automatic switching from Arming Failed status to Armed status after zone s being restored On Off Off Auto Arming After Alarm Automatic switching from ntrusion Alarm Fire Alarm or Fire Prealarm status to the Armed status upon restoring the zone On Off Off Disarmed Zone Monitoring Enables to transfer
24. set the time double click by left mouse button on the field and type a proper value or select the value by arrow buttons 93 www bolid com SECURITV SVSTEMS Orion ISS Alarm Delav This option is to be programmed for zones of the Type 7 representing the time of delav be tween the moment of breaking the armed zone and the moment of switching the zone to an alarm status followed bv activating alarms running for relevant relavs the common executive programs 1 8 and 12 Siren By default this time is equal to 0 and can be increased up to 255 seconds To program an Alarm Delav or entrv delav double click bv left mouse button on the field and tvpe a proper value or select the value bv arrow buttons Fire Dav Sensitivitv Threshold This option is to be programmed for zones of the Type 8 representing the smoke obscuration level measured bv the assigned smoke detector in the Dav mode and converted to a digital value on having reached which the S2000 KDL generate a Fire Alarm message for the zone Bv default the threshold value is equal to 100 and can be changed in the range of 90 to 120 To set or change the value of the threshold double click bv the left mouse button on the rele vant box and tvpe a proper value or select the value bv arrow buttons Prealarm Dav Sensitivitv Threshold This option is to be programmed for zones of the Type 8 representing the smoke obscuration level measured bv the assigned smoke detector in the Dav mode an
25. status changes for disarmed intrusion zones of types 4 5 7 11 On Off Off Never Disarmed The zone is armed permanently and cannot be disarmed On Off Off Arm Disarm by Group Upon controller s receiving a Group Arming Disarming command from the network controller all zones with this parameter being set are armed disarmed all at once the pa rameter is valid only for those zones which are assigned to specific device types in the controller database On Off Off Arming Delay The delay between receiving an arming command and switching the zone to the Armed status 02005 Recoverv Time The time during which a zone of the Type 6 should be in norm to consider this zone to be recovered Also this is the time for operating given tactics Auto Arming After Alarm Disarmed Zone Monitoring 0 255 s 19 www bolid com SEGURITV SVSTEMS Orion ISS Factory When this time is elapsed the zone of the Type 7 will be switched Alarm Delay from Entrance Alarm status Me to the Intrusion Alarm status Fire Day The level of smoke in terms of stand Sensitivity ard units to respond with a Fire Alarm 90 120 100 Threshold message for Day mode Prealarm Day The level of smoke in terms of stand Sensitivity ard units to respond with a 70 90 80 Threshold Fire Prealarm message for Day mode Fire Night The level of smoke in terms of stand S
26. ter minals of the controller has been restored This message is not supported yet A short circuit failure has happened in the polling loop or one of its branches Failure to supply the required power to the polling loop or one of its branches Actually this message appears when the voltage in the polling loop its branch exceeds the output voltage of the S2000 KDL The polling loop operates correctly The power of the S2000 KDL was turned off and then turned on again The power voltage at the inputs U1 and or U2 has dropped below 9 3 V 59 www bolid com SEGURITV SVSTEMS Orion ISS POWER RESTORE The power voltage at the inputs 4U1 and or U2 has exceeded 9 8 V Are generated in a case if the Ring Topologv switch is set on see Section Setting Operating Parameters of the S2000 KDL of this Manual Depending on the number of connected power supplies and the current setting of the Both Power Inputs Monitoring parameter see Section Setting Operating Parameters of the S2000 KDL of this Manual Remote Controlling the S2000 KDL over the RS 485 Interface The S2000 KDL provides execution of the following commands received over the RS 485 interface from the relevant S2000 C2000M console or management software of the Orion system the Orion Pro software or the UProg configuration tool Y Load Configuration into S2000 KDL Assign the Network Address Arm Disarm a zone or a group of zones Reset Alarms
27. the S2000 ASR2 the accumulated num ber is lost So for a zone of the Type 13 the parameter Counting Threshold is to be specified which is a number of pulses that are accumulated in the S2000 ASR2 memory before sending this number to the S2000 KDL The controller summarizes the received values and stores them into own non volatile memory The maximum number of pulses that can be stored in the memory of the S2000 KDL is 2 10 The value of Counting Threshold should be selected so that on the one hand this value can be ig nored in case of shutting down power or any other failure of the S2000 ASR2 but on the other hand sending pulses would not overload the polling loop of the S2000 KDL The Counter Integral Action Time parameter allows avoiding false count pulses for different types of meters The value of Counter Integral Action Time is set so that it was maximum two times less than duration of a countable pulse 33 www bolid com SEGURITV SVSTEMS Orion ISS Zone Tvpe 15 Humiditv Measurement Zone Type 15 is used for monitoring the hvdrometrical channel of an S2000 VT addressable com bined temperature 8 humiditv sensor For this type of zone the S2000 KDL provides measuring hu miditv values while operating humiditv control installations The S2000 KDL requests digital values of measured humiditv through its polling loop when it is in the quiescent mode The Humiditv Increased Threshold and Humiditv Decreased Threshold should be giv
28. the current descriptor and set the flag Copy Only the Current Setting on If you need to copy zone parameters along with its input to output links tick the Copy Input to Output Matching box www bolid com 98 S2000 KDL Programming Programming Addressable Outputs of the S2000 KDL Addressable zones of the polling loop defined as outputs see Section Registering Addressable De vices Connected to the Polling Loop of this Manual are to be described on the Outputs tab of the UP rog see Figure 16 Here each addressable output is assigned to input addressable zones of the S2000 KDL in case of local control as well as to parameters of local control such as an executive program activation time and activation delav and so on UPROG Configuration Tool for S2000 KDL version 1 46 File Device l Help d H Relay Dutputs Properties Executive Program Relay Activation Time Activation Delay And Or Logic Temperature Increased Threshold Temperature Decreased Threshold Humidity Increased Threshold Humidity Decreased Threshold Device Type AZones ADevice Outputs A Valves A Access Groups A Keys Figure 16 Programming Addressable Outputs of the Polling Loop The columns at the top part of the window contain descriptors of addressable outputs programmed on the Device Type tab of the UProg the loop addresses of the relay outputs are shown at the tops of the columns The upper window displays links between the selecte
29. the list of keys and the defragmenting the S2000 KDL key memory Use this command to facilitate key handling and to clear the controller memory from the keys which are marked as deleted if the list of keys are full the last key in the list has the number 512 The algorithm of defragmentation works by the principle of replacing the first found deleted key by an active key Thus the numbers of the keys in the list after defragmentation will differ Save Results When key handling is completed the amended key list MUST BE WRITTEN to the S2000 KDL memory by means of Write Keys to Memory tool pressing the button After activation the described command all previously written keys at the controller memory are cleared The key memory area is isolated from other memory areas and is handled separately To save keys use only the toolbar Write Keys to Memory tool rather than other UProg save commands The keys with their attributes can also be written to a special file with the extension of ki which then can be loaded to an UProg at this another PC for example to facilitate setting of other S2000 KDL controllers The Save Keys to File command N button is to be used for this pur pose 109 www bolid com SEGURITV SVSTEMS Orion ISS www bolid com 110 S2000 KDL Maintenance MAINTENANCE 111 www bolid com SECURITY SYSTEMS Orion ISS This Section discusses some possible minor faults while S2000 KDL operating and m
30. two color LEDs located on the front panel of the S2000 KDL indicate respectively controller s power conditions conditions of communicating data through the RS 485 interface bus and conditions of the polling loop and communicating data over the polling loop A special option of the controller configuration provides the light indication which is need by requirements of European Standard www bolid com 8 S2000 KDL General EN54 2 Optionally the S2000 KDL can also control the indication of connected addressable devices if the devices support The controller is to be powered by one or two main and extra power supplies providing 12 V dc or 24 V dc It is strongly advised to use Bolid manufactured battery backed power supplies of RIP series The S2000 KDL is programmed to meet particular user conditions and specific user needs by means of the configuration tool for Orion devices the UProg The latest version of the UProg Configuration Tool can be downloaded from the Bolid Company website at the address of www bolid com To be programmed by means of UProg the S2000 KDL must be connected to the PC with the installed UP rog via one of the Bolid manufactured interface converters such as PI GR S2000 PI S2000 USB or USB RS485 The S2000 KDL is equipped with a tamper switch which provides tamper alarms when tamper condi tions are changed and transferring the alarms to a network controller Non volatile memory of the controller is used to sto
31. using the controller in engineering systems providing releasing extinguishing agent keeping temperature and humidity within the preset range air condi tioning and ventilation control utilitv submetering turning equipment on off reading digital output signals from engineering equipment and so on A number of networked controllers up to 63 x1024 S2000 KDL within a single Orion system can be a base for creating flexible and high scalable systems providing centralized security monitoring for any sized applications scattered over large geographic areas with communicating data through vari ous channels including public switched telephone networks cellular networks and LAN The S2000 KDL along with S2000 ASR2 consumption metering controllers can be used in specialized utilitv submetering installations operated under the Resource software Also S2000 KDL controllers can be used to expand inputs of technological controllers S2000 T in building automation systems operating under Algorithm software The S2000 KDL provides monitoring and control for up to 127 connected addressable devices see Figure 1 The following initiating devices as well as auxiliary devices can be polled by the S2000 KDL in any combination Analogue addressable photoelectric smoke detectors DIP 34A Analogue addressable fixed temperature and rate of rise detectors S2000 IP Addressable manual call points IPR 513 3A Addressable input modules S2000 AR1 S2000 AR
32. various executive devices which should be turned on upon entering one of the zones assigned to the output to Fire Alarm or Intrusion Alarm status The initial status for the programs 1 3 5 7 is Off Open while the initial status for the programs 2 4 6 8 is On Closed 43 www bolid com SECURITV SVSTEMS Orion ISS When a zone linked with the programmed relav enters a Fire Alarm or Intrusion Alarm sta tus the output is activated accordingly to assigned executive program On disarming or arming the zone being broken all outputs linked with the zone return to their initial status es Moreover outputs operated by programs 3 4 7 and 8 return to their initial sta tuses on elapsing the time equal to Relay Activation Time for each these outputs The re lay can also be switched to an initial status by a Reset Alarm command sent over the RS 485 interface from S2000 M console or Orion PC If relav outputs are controlled centrally by network controller commands the initial status es of outputs are defined by initial statuses of assigned executive programs Executive Program 9 Lamp The executive program 9 Lamp is to be used when the relay is supposed to control a light alarm The status On Closed means that the contacts of the relay outputs are closed Executive Program 15 Fire Lamp The difference between programs Lamp and Fire Lamp is that the output is turned on only if all zones assigned to this output are armed
33. 2 S2000 AR8 to provide connecting conventional zone type detectors to the polling loop of the S2000 KDL Addressable intrusion detectors S2000 IK S2000 V S2000 ST S2000 STIK S2000 SHIK S2000 PIK S2000 MW S2000 SMK S2000 SMK Estet etc Addressable panic buttons S2000 KT Addressable expansion modules LEM Ex rev 2 to connect intrinsically safe alarm loops to the polling loop of the S2000 KDL Addressable combined temperature and humidity sensors S2000 VT VV VV VY NN WV Addressable controllers for two pulse output meters S2000 ASR2 www bolid com 6 S2000 KDL General Orion Pro S2000 M S2000 BKI RIP 12RS RIP 24 Software Fire amp Alarm Console Control amp Indicator Battery Backed Battery Backed Module Power Supply Power Supply KI 12V RS 485 up to 127 devices Mike ise E 24 V backup power S2000 KDL u Multiplex Addressable S2000 VT Polling Loop Controller Combined Temperature and Humidity Sensor kd P BRIZ Short Circuit Isolator S2000 KT Panic Button gt S2000 IP 4 Analogue Fixed Temperature S2000 ST gt and Rate of Rise Detector Glass Break IPR 513 3A EN Detector Manual Fire Alarm DIP 34A Analogue Smoke Detector S2000 STIK Combined Motion and Glass Break Detector au ressable Input d Module 4 a S2000 SHIK N j See Curtain UE o PIR Motion Detector Addressable M Fra ECHO 5 Module Non addressable Ultrasonic Motion qi AR2 Detector 0
34. 4 The command Change Loop Address allows replacing the loop address of an addressable device connected to the S2000 KDL from the known current address to the given address In case of select ing the command for an addressable zone the UProg output a dialog box where a new address should be typed www bolid com 88 S2000 KDL Programming For the devices occupving more than a single address within the polling loop changing an address specifv the least of all addresses to be assigned The next adjacent addresses will be assigned to monitored circuits of the device successivelv in ascending order Requesting Parameters of Addressable Devices If an addressable device connected to the polling loop supports the data communication protocol DPLS v2 xx the UProg can request device s parameters by means of following commands Request the Device Type The command allows you to find out what addressable device is found by the controller at the current address Request the ADC Value The command returns the digitized current value of some parameter measurable by the con nected addressable device this value being in the range of 0 to 254 For different addressable devices ADC values have different meanings For example for a DIP 34A the ACD value is the current smoke level for an S2000 IP it is the value of ambient temperature in C while for an IPR513 3A this one displays the status of the manual call point see the documentation for used
35. Condition Fire Alarm status the relay is switched on and off alternately Otherwise the relay is on If an assigned input zone has entered the Intrusion Alarm or Blink For a Time From Off Fire Alarm status the relay is switched on and off alternately Condition for a time given by the Relay Activation Time for this output Otherwise the relay is off If an assigned input zone has entered the Intrusion Alarm or 8 Blink For a Time From On Fire Alarm status the relay is switched on and off alternately Condition for a time given by the Relay Activation Time for this output Otherwise the relay is on www bolid com 40 S2000 KDL Operation Principles LEN CIR RN If an assigned input zone has entered such status as Intrusion Alarm Entrance Alarm Fire Alarm Fire Prealarm 9 Lamp Trouble Disconnected or Arming Failed the relay is switched on and off alternately If an assigned input zone is armed the relay is switched on If all zones are disarmed and being in norm the relay is off If all assigned zones are armed the relay is switched on 10 EIOS Otherwise the relay is off If two or more assigned fire zones have entered Fire Alarm l status and no assigned auxiliary zones are broken the relay 11 Discharge is switched on for a time given by the Relay Activation Time for this output If an assigned zone has entered Fire Alarm or Fire Prealarm status the relay is switched on and off alternately fo
36. ECURITV SVSTEMS Orion ISS At the right bottom part of the window a name of the device assigned to a current selected address able zone is displayed White fields under each address can be marked by the sign if the zone is included into the selected Access Group or otherwise be empty if the zone doesn t concern to this Access Group To include some addressable zones of the S2000 KDL into an Access Group select the Access Group number in the upper list and double click each of the addressable zones Now upon present ing a key assigned to this Access Group the specified zones will be armed disarmed To eliminate some addressable zones of the S2000 KDL from an Access Group that is to prohibit arming disarming the zones for a key with this Access Group clear fields of these zones by left double click Right click at any place of the bottom window enables including into a selected Access Group all ad dressable zones of the controller or unselect all zones to facilitate configuration process in some cas es Figure 17 shows an example of programming the Access Group 5 For the current addressable zone 15 the type of the connected device the temperature channel of the S2000 VT is shown below in the status line In addition to the selected zone 15 the Access Group 5 includes also the addressa ble zones 2 4 7 and 14 all these zones will be armed and disarmed upon presenting a key with Access Group 5 at the reader
37. G Reader green LED control circuit BEEP Reader sounder control circuit Connecting Readers with Touch Memory Output Interface Figure 8 and Figure 9 show wiring diagrams for connecting readers with Touch Memory Output Inter face to the S2000 KDL S2000 KDL Figure 8 Connecting a Dallas iButton Reader to the S2000 KDL 71 www bolid com BOLID SECURITY SYSTEMS Variant 1 Suitable for readers located within 50 m from the S2000 KDL which current consumption doesn t exceed 100 mA S2000 KDL Orion ISS Variant 2 Suitable for readers with high current consumption or far more than 50 m from the controller Reader S2000 KDL Figure 9 Connecting Readers with Touch Memorv Output Interface to the S2000 KDL Connecting Readers with Wiegand Output Interface Figure 10 shows a wiring diagram for connecting readers with Wiegand Output Interface to the S2000 KDL Variant 1 Suitable for readers located within 50 m from the S2000 KDL which current consumption doesn t exceed 100 mA S2000 KDL Reader Variant 2 Suitable for readers with high current consumption or far more than 50 m from the controller S2000 KDL Figure 10 Connecting Readers with Wiegand Output Interface to the S2000 KDL www bolid com S2000 KDL Installation CONNECTING AN ARMING REQUEST BUTTON OPTIONAL In case of centralized control in an Orion system user s electronic keys or authentica
38. Ie EI SECURITY SYSTEMS Orion ISS READY B RS 485 B Loop B 2000 KDL Addressable Polling Loop Controller S2000 KDL User s Manual This User s Manual is intended to help for studying operabilitv principles and maintenance of the S2000 KDL Addressable Polling Loop Controller of version 1 46 Please read the instructions completely before connecting operating adjusting or maintain ing this product The following terms are used throughout the Manual Addressable Device The device which supports a special protocol of communicating data with the S2000 KDL Each addressable device must be assigned to a unique number of 1 to 127 which is programmed either by DIP switches on its PCB or stored in the device non volatile memory An addressable device can be a fire or intrusion detector or call point or input module or tem perature amp humidity sensor S2000 VT or utility meter S2000 ASR2 or expansion module LEM Ex rev 2 or executive module S2000 SP2 etc Polling Loop The two wire multiplex addressable loop of the S2000 KDL through which the control ler communicates data with and supplies power to connected addressable devices Loop Address A unique number of the addressable device within the polling loop of the S2000 KDL Addressable Zone The minimal independently monitored controlled point in the polling loop of the S2000 KDL similar to an alarm loop for a non addressable installation An S2000 KDL sup ports
39. L provides executing group commands for arming disarming received from the net work controller for those zones which have the Group Arming Disarming switch set in the S2000 KDL configuration For fire and intrusion protection zones of Types 1 5 7 9 and 11 receiving an Arm command causes the controller to arm the zone If before receiving the command the zone was in norm it is armed with the S2000 KDL sending the network controller via the RS 485 interface the message about arming the zone In any other case the S2000 KDL considers the zone status to be Arming Failed and transmits this status to the network controller A zone of the Type 8 is considered by the S2000 KDL to be in the Arming Failed status if the value measured by the smoke detector has exceeded the Prealarm or Fire sensitivity threshold predeter mined for the zone for the current time of the day Day or Night mode If the value received from the addressable device is less than the thresholds said above then the zone enters Armed status the S2000 KDL sending the relevant message If a zone of the Type 9 for which the measured temperature has exceeded the predetermined Fire of Prealarm temperature is armed it will be considered as being in Arming Failed status with transmit ting the relevant message 35 www bolid com SECURITV SVSTEMS Orion ISS If non zero Arming Delay is programmed for an intrusion protection zone the zone will be armed after expiring t
40. LL BE THE COMPLETE AND EXCLUSIVE REMEDY AGAINST SELLER This warranty gives you specific legal rights and you may also have other rights which vary from country to country No increase or alteration written or verbal to this warranty is authorized 4 Pionerskava Str Korolev 141070 Moscow Region Russia Phone fax 47 495 775 71 55 Email info bolid ru overseas bolid com www bolid com
41. MS Orion ISS Local Executive Programs for Controlling Polling Loop Outputs Table 4 represents all available control tactics executive programs which can be realized bv the S2000 KDL in case of local controlling of relav outputs Table 4 Local Executive Programs for Outputs of the Polling Loop Te In Local control is disabled 0 Remote Control The relay can be controlled remotely over the RS 485 inter face by a network controller command If an assigned input zone has entered the Intrusion Alarm or 1 Switch On Fire Alarm status the relay is switched on Otherwise the relay is off If an assigned input zone has entered the Intrusion Alarm or 2 Switch Off Fire Alarm status the relay is switched off Otherwise the relay is on If an assigned input zone has entered the Intrusion Alarm or Fire Alarm status the relay is switched on for a time given by Switch OM For a Time the Relay Activation Time for this output Otherwise the relay is off If an assigned input zone has entered the Intrusion Alarm or Fire Alarm status the relay is switched off for a time given by 5 MIO ore dia the Relav Activation Time for this output Otherwise the relav is on If an assigned input zone has entered the Intrusion Alarm or Fire Alarm status the relay is switched on and off 5 Blink From Off Condition alternately Otherwise the relay is off If an assigned input zone has entered the Intrusion Alarm or 6 Blink From On
42. N VP a ee S2000 PIK a palit Ceiling PIR Motion saet Detector ulti S2000 IK PIR Motion Detector S2000 AR S2000 SP2 Addressable Input Module 2000 SMK Estet S2000 SMK Magnetic Contact Light Alarm Sound Alarm Figure 1 Analogue Addressable Message Transferring Svstems Based on S2000 KDL 7 www bolid com SECURITV SVSTEMS Orion ISS The S2000 KDL polls the connected devices and coordinates their operating powering them and communicating data via the polling loop The S2000 KDL provides 13 various monitoring tactics which can be programmed individually for each addressable zone of the polling loop Among them gt Five various tactics of monitoring fire protection zones gt Four tactics for monitoring zones protected against intrusions gt Four tactics for monitoring auxiliary or technological zones including thermostatic humidity measurement and counting used to integrate various measurement and signaling equipment into fire amp intrusion alarm installations In a small security system which doesn t require high informative the S2000 KDL can operate standalone activating connecting relay modules in response to changing zone conditions accordingly to programmed cause amp effect logic However all features of the S2000 KDL can be fully realized on ly when it operates as a part of on Orion system under a network controller which can be S2000 M control console or Orion Pro software Operating under the netwo
43. NO CASE SHALL SELLER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER S OWN NEGLIGENCE OR FAULT Some countries do not allow limitation on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you Seller does not represent that the product may not be compromised or circumvented that the product will pre vent any personal injury or property loss by burglary robbery fire or otherwise or that the product will in all cases provide adequate warning or protection Buyer understands that a properly installed and maintained alarm may only reduce the risk of a burglary robbery fire or other events occurring without providing an alarm but it is not insurance or guarantee that such will not occur or that there will be no personal injury or property loss as a result CONSEQUENTLY SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY PROPERTY DAMAGE OR OTHER LOSS BASED ON A CLAIM THE PRODUCT FAILED TO GIVE WARNING HOWEVER IF SELLER IS HELD LIABLE WHETHER DIRECTLY OR INDIRECTLY FOR ANY LOSS OR DAMAGE ARISING UNDER THIS LIMITED WARRANTY OR OTHERWISE REGARDLESS OF CAUSE OR ORIGIN SELLER S MAXIMUM LIABILITY SHALL NOT IN ANY CASE EXCEED THE PURCHASE PRICE OF THE PRODUCT WHICH SHA
44. Request Protocol Return statuses of all the zones Synchronize the Internal Clocks Local Programming Mode Control Switch to the Detector Test Mode VON ON ON NO NON ON WV Turn the Output On Off Y Request Zone Settings Most of these commands are sent by means of the network controller and detailed in its Manual The S2000 KDL is configured by the UProg utility The UProg provides assigning the controller to a network address requesting current zone parameters as well as remote programming addressable devices connected to the S2000 KDL for example assigning loop addresses to the addressable de vices which store them in their non volatile memories see Sections Network Settings of the S2000 KDL Programming Loop Addresses of Addressable Devices and Requesting Parameters of Ad dressable Devices of this Manual relatively A Switch to the Detector Test Mode command sent by tools of the network controller provides regulat ing testing addressable devices brought into the polling loop according to the following algorithms www bolid com 60 S2000 KDL Operation Principles a b Testing smoke detectors in the Fire Alarm mode While a test action is applied to a DIP 34A supporting DPLS 2 xx a magnet is put to a detector the test button is pushed or laser tester operates and the detector is switched to a special test mode the S2000 KDL generates a FIRE ALARM message for the zone If the said test mode is disabled the
45. SS olds between Night and Dav time zones and alternativelv Bv default these values are set to 9 00 and 21 00 UPROG Configuration Tool for S2000 KDL version 1 46 EIER File Device Help jj H Whe Night to Day Threshold E Haj Day to Night Threshold 21 00 a Reader s Output Interface TouchMemoy LED Control Polarity Forward 1 active Number of Reader LEDs etED sl Sounder Control Polarity Forward 1 active Enable Sounding iv Maximum PIN code Length 6 Both Power Inputs Monitoring EN 54 Indication Ring Topology Device Type Device AQutputs Figure 13 Settings of the S2000 KDL and the External Reader Both Power Inputs Monitoring If the S2000 KDL is powered by two power supplies the parameter specifies the condition for the controller to enter the Power Failed mode upon dropping or shutting off voltage at least at one power input of in case of a both power supply s failure If the parameter is set on the S2000 KDL generates a Power Failed message when power supply voltage has dropped below 9 3 V at least at one power input while a Power Restored message is generated upon voltage s exceeding 9 8 V at both power inputs If the parameter is set off default setting then a Power Failed message is generated upon voltage s dropping at both power inputs while a Power Restored message is generated when a normal voltage value has returned at least at one power input To turn the Both Po
46. STEMS Orion ISS Light and Sound Indication of the Reader If a proper reader is connected to the S2000 KDL then the reader s LED LEDs and sounder if ena bled displav the dialog between users and the S2000 KDL or network controller while users request access to various svstem operations see Section Controlling S2000 KDL Input Zones and of this Manual Table 10 represents events and svstem conditions that can be indicated bv the reader LED LEDs depending on how many LED control outputs of the reader one or two are used by the controller that is given bv the Number of Reader LEDs parameter see Section Configuration Parameters of Readers and User Authenticators of this Manual Table 11 represents events and svstem conditions that the S2000 KDL can output on the reader sounder if only Sounding Enabled parameter is set on see Section Configuration Parameters of Readers and User Authenticators of this Manual Table 10 Reader Light Indication Event Condition Two Control Outputs Single Control Output The presented electronic key authenticator is not found in Lights in red and green the S2000 KDL memory the alternately controller is waiting for a deci five times per second sion of the network controller Flashes five times per second Access is closed prohibited Lights in red for a second Lights for a second or access is denied Access is granted Lit steadv in green Lit steadv Zones or Partitions Are A
47. TAM PER contacts of the S2000 ARI is closed there is no faults TAMPER ALARM The enclosure of the addressable detector or input module being in statuses Disarmed or Arming Failed or Arming Delay is open NOT READY TO ARM The zone has been broken the Disarmed Loop Monitoring parame ter being set on www bolid com 28 S2000 KDL Operation Principles TROUBLE The addressable device has failed ARMING DELAV Arming the zone is delaved until the Arming Delav time has elapsed ARMING FAILED The parameter monitored bv the addressable device is out of normal range at the time of arming the zone ENTRANCE ALARM The addressable detector has responded or The contacts of the S2000 SMK has been open or The monitored circuit of the addressable input module has entered one of the statuses described by Table 2 for zones of the Type 7 INTRUSION ALARM The Alarm Delay time has elapsed after zone s having entered the Entrance Alarm status An addressable device trouble has occurred with the zone being armed Zone Tvpe 8 Smoke Analogue With Programmable Thresholds A zone of the Tvpe 48 is intended to monitor analogue addressable smoke photoelectric detectors DIP 34A DIP 34A rev 01 and DIP 34A rev 02 operated in analogue mode The polling loop being in the quiescent mode the controller requests the digital values of smoke con centration measured by the detector For each zone of the Type 8 the Prealarm Sensitivity
48. TT eaaenkes Locally Indicated Troubles Troubles of the S2000 KDL Transferred to the Orion System Preventive Maintenance coe rind Self Diagnostic Routine www bolid com 4 Orion ISS 68 68 69 M 70 Q 70 70 71 72 73 t 73 76 77 77 PT 79 79 81 61 61 84 85 86 88 89 90 91 97 98 99 99 100 103 105 107 108 109 109 112 112 113 115 115 S2000 KDL General GENERAL 5 www bolid com SECURITV SVSTEMS Orion ISS S2000 KDL Multiplex Addressable Polling Loop Controller hereinafter referred to as the S2000 KDL or the controller is the basic component of the SPI 2000A Addressable Message Transferring System which in turns is a part of an Orion integrated security system The S2000 KDL provides designing complex and high informative addressable and analogue addressable installations to protect industri al commercial and residential premises of any size The S2000 KDL provides effective managing fire detection due to the facilities such as delayed sounder response to allow investigation time day night sensibilitv adjustment of individual devices pre alarm and contamination warning etc Through connected addressable executive modules the S2000 KDL can control executive devices such as light and sound alarms by means of one of the 37 available executive programs Built in control tactics of the S2000 KDL enable
49. To turn it on tick the box at the right of the parameter by the left mouse button 83 www bolid com SEGURITV SVSTEMS Orion ISS Programming Reader Parameters Parameters of the external ID reader connected to the S2000 KDL are adjusted on the Device tab of the UProg see Figure 13 Reader s Output Interface Specify select from the dropdown list the type of the output interface of the reader which is the way the code of the presented key is to be transferred to the controller Touch Memory by default or Wiegand LED Control Polarity This parameter defines the active logic level to control readers LEDs If the Forward polarity is programmed then turning LEDs on is performed by outputting the high logic level logic 1 on the LEDG and LEDR contacts of the controller If the Reverse polarity is selected turning the LEDs on is performed by outputting the low logic level logic O By default the Forward polarity is set such a polarity for example is typical for Touch Memory devices For most readers as a rule the Reverse polarity active 0 is required Se lect the proper polarity from the dropdown list in the field of this parameter Number of Reader LEDs Set the number of reader outputs to control its LED LEDs connected to the controller and used in its operating Sounder Control Polarity This parameter defines the active logic level to activate the sounder of the reader If the For ward polarity is programmed then tur
50. USB RS485 or S2000 USB If a communication loss has occurred during generating a message the relevant event is stored in the non volatile memory of the S2000 KDL When the communication is restored the event will be trans mitted via the RS 485 interface to the network controller with the time and date assigned in accord ance with the internal clock of the S2000 KDL The network controller synchronizes the internal clock of the S2000 KDL to its own clock by sending a Svnchronize Clock command transferred via the RS 485 interface commoniv at the beginning of each hour The S2000 KDL provides buffering up to 255 events in its non volatile memorv The S2000 KDL transmits the network controller the following events specifving the time and date of their origin DISARMED The addressable zone is disarmed ARM DELAY A predetermined delay is being counted before arming the zone ARMED The addressable zone is armed ARM FAILED Trying to arm the zone has failed due to zone s not being in norm LOOP TRBL OPEN The circuit which connects the addressable device into the polling loop of the S2000 KDL has been open LOOP TRBL SHORT A short failure has been detected in the circuit which connects the addressable device into the polling loop of the S2000 KDL DISCONNECTED Communications between S2000 KDL and the addressable device has been lost CONNECTED Communications between S2000 KDL and the addressable device has been restored FIRE PREALARM The ad
51. addressable devices The value of 255 is returned for zones which addressable devices cannot transfer analog values Request the Contamination Value The command returns a value of contamination within the DIP 34A smoke chamber measured in conventional units Request the Device Voltage The command returns a value of polling loop voltage at the location of the addressable device To request any parameter of an addressable device right click the device address and select the proper command in the lower part of the context menu see Figure 14 Selected command s having returned the value of 255 means that this addressable device doesn t support the command 89 www bolid com SEGURITV SVSTEMS Orion ISS Programming Input Addressable Zones of the S2000 KDL The zones of the polling loop which are defined as inputs see Section Registering Addressable De vices Connected to the Polling Loop of this Manual are to be programmed on the Zones tab of the UProg see Figure 15 UPROG Configuration Tool for 2000 KDI version 1 46 PER File Device language Help d b Addressable Zone Details Zone Type Auto Rearming Auto Arming After Alarms Disarmed Zone Monitoring Never Disarmed Arm Disarm by Group Arming Delay s Recovery Time s Alarm Delay s Fire Day Sensitivity Threshold Prealarm Day Sensitivity Threshold Fire Night Sensitivity Threshold Prealarm Night Sensitivity Threshold Contamination Threshold Fire Te
52. ally safe loop extension modules Available statuses of a zone of the Type 5 are the following ARMED The zone is fully monitored DISARMED The zone is in a norm the Disarmed Loop Monitoring parameter being set on the addressable device enclosure is closed the TAM www bolid com 26 S2000 KDL Operation Principles PER contacts of the S2000 AR1 is closed there is no faults TAMPER ALARM The zone being in one of the statuses Disarmed Arming Failed or Arming Delay the enclosure of the addressable device or addressa ble input module is open or the TAMPER contacts of the S2000 AR1 is open NOT READY TO ARM The zone has been broken being disarmed the Disarmed Loop Monitoring parameter being set on TROUBLE The addressable device has failed ARMING DELAY Arming the zone is delayed until the Arming Delay time has elapsed ARMING FAILED The parameter monitored by the addressable device is out of normal range at the time of arming the zone INTRUSION ALARM The addressable detector has responded with an alarm for exam ple breaking a glass has detected or infrared field has been vio lated or The contacts of the S2000 SMK has been open or The detector enclosure has been open or The addressable device has failed provided that the zone was armed or The status or the input module s monitored zone is not Norm Zone Type 6 Auxiliary Auxiliary zones are intended to monitor statuses of doors in gaseou
53. armed Loop Monitoring parame ter being set on www bolid com 32 S2000 KDL Operation Principles TROUBLE The addressable device has failed ARMING DELAV Arming the zone is delaved until the Arming Delav time has elapsed ARMING FAILED The parameter monitored bv the addressable device is out of normal range at the time of arming the zone PANIC ALARM Breaking of the monitored circuit of the input module has been de tected see Table 2 the device has failed provided that the zone is being armed Zone Tvpe 13 Counting A zone of the Type 13 is designed to connect addressable controllers S2000 ASR2 with one or two included pulse output meters of water gas etc Available statuses of a zone of Tvpe 13 are the following CONNECTED The S2000 ASR2 is connected pulses are being counted SHORT CIRCUIT A short circuit failure in a monitored circuit of the S2000 ASR2 no pulses are counted OPEN CIRCUIT A monitored circuit of the S2000 ASR2 is open no pulses are counted This type of zone is to be used when the addressable pulse meter controllers connected to the S2000 KDL operate in a utilitv submetering system controlled by Recourse or Orion Pro software An S2000 ASR2 is designed to control utility meters with pulse outputs for which a single pulse corre sponds to a certain amount of measured physical material The counted number of pulses is stored in the RAM of the S2000 ASR2 so on shutting off the power of
54. ase of in sufficient wire cross section or the current carrying capacity of the polling loop has exceeded its threshold value see Section Connecting the Polling Loop of this Manual or The total capacity of wires has exceeded the threshold value see Section Connecting the Polling Loop of this Manual or gt The addressable device and the polling loop operate in com plex electromagnetic environment created by the equipment used at the facility To analyze parameters of the polling loop you can use the com mand Request the Device Voltage see Section Requesting Pa rameters of Addressable Devices of this Manual The value re turned by the command for a zone will show the amplitude of the supply voltage carried to the device The value of the voltage is considered to be normal if it is equal or above 8 V The type of connected addressable device doesn t match the type of the device programmed for the zone while configuring or the programmed zone type doesn t match the type of the connected addressable device see Sections Registering Addressable Devic es Connected to the Polling Loop and Programming Input Ad dressable Zones of the S2000 KDL of this Manual 113 www bolid com SECURITY SYSTEMS SERVICE REQUIRED FIRE TROUBLE POWER FAILED LOOP TRBL OPEN LOOP TRBL SHORT 2WIRE 1 LOST 2WIRE 2 LOST 2WIRE LINE SHORT x x 2WIRE LINE TRBL www bolid com Orion ISS Such a message w
55. at voltage drop across the input contacts of the addressable device which is the most distant from the S2000 KDL at the end of the branch shall not exceed 2 V estimate the proper resistance of the polling loop Knowing the resistivity of wire material estimate the maximum length of the polling loop branch www bolid com 68 S2000 KDL Installation Example Let 127 smoke detectors DIP 34A or other addressable devices consuming 0 5 amp are supposed to be brought in the polling loop of the S2000 KDL The total current consumption of all the devices is 63 5 mA Taking into account the maximum allowable voltage drop along the polling loop 2 V the polling loop resistance must be equal to 31 50 For with cross sectional area of 0 75 square millimeters the estimated length of the polling loop will be approximately 600 meters while for wires with cross sectional area of 0 9 square millimeters the length will be approximately equal to 700 meters Actually loading real installations has a distributed nature so drop voltage of 2 V occurs for distances more than the estimated length Make estimations for each polling loop segment between two ad dressable devices The resistance of the polling loop to the most distant addressable device shall not exceed 2000 In state of an open failure in the polling loop with ring topology the resistance of the loop and its branches taking into account formed parts of the loop increases So estimating
56. attributes To work with keys stored in the S2000 KDL memory correctly connect the controller to the PC then run the UProg exe and finally load the keys from the S2000 KDL memory ar by means of the button on the Keys tab The UProg also allows handling keys reading them from a file of a special format or en rolling by a reader without loading keys already stored in the controller memory But in such a case upon newly keys being enrolled to the controller memory all data stored in the memory before are cleared Add Edit a Key There are two ways to add keys gt Toread keys from a special file by means of icon or gt To create new key descriptors by means of A icon or pressing ns In last case to add a key 1 Press Add Key button or lt ns gt the new entry named as New Key will appear in the key list 2 Describe the reader which the key being registered will be presented to To do this specify in the boxes located below the key list the network address of an Orion system which the reader is connected to as well as the number of the reader if the device has more than one reader 3 By pressing the button in the Main Key Code field read the code of the key 107 www bolid com SEGURITV SVSTEMS Orion ISS Please remember that see page 105 2 f the code of a key is registered by a reader connected to another device of the Orion system data output format of the remote reader MUST ma
57. com SEGURITV SVSTEMS Orion ISS OUTPUTS OF THE ADDRESSABLE POLLING LOOP If a security installation controlled by the S2000 KDL is supposed to control addressable executive devices such as sirens fire lights guard lights video cameras electric locks or strikes heaters venti lators etc these devices are connected to the polling loop through addressable executive modules S2000 SP2 Also S2000 SP2 modules are used to send commands to release extinguishing agent or to transfer alarms to an Alarm Receiving Center Addressable zones matched with S2000 SP2 modules are configured as addressable outputs of the polling loop see Section Programming Addressable Outputs of the S2000 KDL of this Manual A re lav module can occupy one or two addresses within the polling loop depending on the current posi tion of the S2000 SP2 DIP switches controlling one or two connected executive devices respectively Moreover addressable outputs of the polling loop can be related with virtual relav outputs of expan sion modules for intrinsically safe loops LEM Ex rev 2 Addressable outputs of the polling loop can be controlled either ocally as an effect caused by chang ing statuses of S2000 KDL input zones linked with these outputs or remotely by central commands issued by the network controller through the RS 485 interface A special option of the S2000 KDL configuration enables transferring events about changing statuses of relay outputs to the network
58. ct the value bv arrow buttons www bolid com 94 S2000 KDL Programming Contamination Threshold This option is to be programmed for zones of the Type 8 representing the level of contamina tions inside of the smoke chamber of the detector converted to a digital value on having reached which the S2000 KDL generates a Service Required message for this zone By de fault the threshold value is equal to 50 and can be changed in the range of 10 to 60 To set or change the value of the threshold double click by the left mouse button on the relevant box and type a proper value or select the value by arrow buttons Fire Temperature This option is to be programmed for zones of the Type 6 representing the value of ambient temperature in C measured by the assigned S2000 IP on having reached which the S2000 KDL generates a Fire Alarm message for the zone By default the value of the threshold is equal to 54 C and can be increased up to 85 C To set or change the value of the threshold double click by the left mouse button on the relevant box and type a proper value or select the value by arrow buttons Prealarm Temperature This option is to be programmed for zones of the Type 6 representing the value of ambient temperature in C measured by the assigned S2000 IP on having reached which the S2000 KDL generates a Fire Prealarm message for the zone By default the value of the threshold is equal to 50 C and can be changed in the range
59. cts in materials and workman ship for one vear from date of original purchase under normal use and service Seller s obligation is limited to repairing or replacing at its option free of charge for parts or labor anv product proven to be defective in mate rials or workmanship under normal use and service Seller is not responsible for results where the product is used improperly where it is used for any application it is not intended for used under unacceptable environ mental conditions and mishandled or stored under improperlv Seller shall have no obligation under this warran tv or otherwise if the product is altered or improperly repaired or serviced by anyone other than the Seller In case of defect contact the security professional who installed and maintains your security equipment or the Seller for product repair This one year Limited Warranty is in lieu of all other express warranties obligations or liabilities THERE ARE NO EXPRESS WARRANTIES WHICH EXTEND BEYOND THE FACE HEREOF ANY IMPLIED WARRAN TIES OBLIGATIONS OR LIABILITIES MADE BY SELLER IN CONNECTION WITH THIS PRODUCT INCLUD ING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE ARE LIMITED IN DURATION TO A PERIOD OF ONE YEAR FROM THE DATE OF ORIGINAL PURCHASE ANY ACTION FOR BREACH OF ANY WARRANTY INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY MUST BE BROUGHT WITHIN 12 MONTHS FROM DATE OF ORIGINAL PURCHASE IN
60. d converted to a digital value on having reached which the S2000 KDL generate a Fire Prealarm message for the zone Bv default the threshold value is equal to 80 and can be changed in the range of 70 to 90 To set or change the value of the threshold double click bv the left mouse button on the relevant box and tvpe a proper value or select the value bv arrow buttons Fire Night Sensitivitv Threshold This option is to be programmed for zones of the Type 8 representing the smoke obscuration level measured bv the assigned smoke detector in the Night mode and converted to a digital value on having reached which the S2000 KDL generate a Fire Alarm message for the zone By default the threshold value is equal to 90 and can be changed in the range of 80 to 100 To set or change the value of the threshold double click bv the left mouse button on the relevant box and tvpe a proper value or select the value bv arrow buttons Prealarm Night Sensitivitv Threshold This option is to be programmed for zones of the Type 8 representing the smoke obscuration level measured bv the assigned smoke detector in the Night mode and converted to a digital value on having reached which the S2000 KDL generate a Fire Prealarm message for the zone Bv default the threshold value is equal to 70 and can be changed in the range of 70 to 80 To set or change the value of the threshold double click bv the left mouse button on the relevant box and tvpe a proper value or sele
61. d output column and input ad dressable zones of the S2000 KDL which are highlighted in green The zone which is assigned to the output is marked by the sign Programming Outputs for Remote Control To control a selected addressable output of the polling loop centrally and remotely by means of net work controller commands do the following gt Make sure the output is assigned to no input zone of the polling loop all fields on the map of Out put to zone bindings are empty or clear the bindings if presented by left click and 99 www bolid com SEGURITV SVSTEMS Orion ISS gt Set the Executive Program parameter to 0 Remote Control for the output or select the program Which implies a suitable output status on or off To do this double click bv left mouse button on the parameter field and then select a proper program from the dropdown list If there is an addressable zone of the S2000 KDL linked to the output all remote control e commands received from the network controller for this output over the RS 485 inter face will be ignored Local controlling the outputs has a higher priority than centralized controlling these ones When necessary to send the network controller messages about changing status of an output upon output s being on or off set the parameter Notify on Changing Relay Statuses to the value of Yes Programming Outputs for Local Control For the outputs of the polling loop which are supposed to
62. day mode Night Day The DIP 34A fails to measure smoke level The Contamination Threshold or the contamination self compensation threshold for the smoke chamber of the DIP 34A has been exceeded Zone Type 9 Heat Analogue With Programmable Thresholds A zone of the Type 9 is intended to monitor analogue addressable fixed temperature and rate of rise detectors S2000 IP S2000 IP rev 01 and S2000 IP rev 02 operated in analogue mode The polling loop being in the quiescent mode the controller requests the digital values of temperature measured by the detector For each zone of the Type 9 the Prealarm Sensitivity Threshold and Fire Sensitivity Threshold are to be programmed to issue fire prealarms and fire alarms respective ly Available statuses of a zone of the Type 9 are the following ARMED DISARMED ARMING DELAY ARMING FAILED FIRE PREALARM FIRE ALARM TROUBLE www bolid com The zone is monitored neither Fire nor Prealarm thresholds are exceeded The zones is monitored only for troubles Arming the zone is delayed until the Arming Delay time has elapsed While the zone is being armed one or more of its programmed thresholds Fire Sensitivity Threshold or Prealarm Sensitivity Threshold is ex ceeded or a trouble has occurred The temperature measured by the detector has exceeded the Prealarm Sensitivity Threshold preprogrammed for the zone The temperature measured by the detector has exceeded the Fir
63. dressable fire detector has sent a signal which can indicate a fire in the area assigned with this addressable zone FIRE ALARM A fire has been detected in the fire protection zone INTRUSION ALARM An intrusion has been detected in the intrusion protection zone ENTRY ALARM An entry has been detected in the entrance zone SILENT ALARM An alarm has been received from the panic zone TAMPER ALARM The controller s or detector s closure has just been open TAMPER RESTORE The controller s or detectors closure has just been closed 57 www bolid com SECURITY SYSTEMS ZONE CONFIG ERR SERVICE REQUIRED FIRE TROUBLE FIRE TEST FIRE TEST BEGIN FIRE TEST END NOT READY TO ARM READY TO ARM AUX ZONE ALARM AUX ZONE RESTORE TEMPERATURE HIGH TEMPERATURE NORM TEMPERATURE LOW LEVEL HIGH LEVEL NORM LEVEL LOW RELAY DISCONNECT www bolid com Orion ISS A configuration conflict has been detected for the zone either the type of the connected device doesn t match to the device type which was specified while configuring the controller or the specified zone type tactics of monitoring doesn t match to the specified device type The zone requires some service for example the smoke chamber of the DIP 34A is contaminated A trouble of the addressable device This message is obsolete and can be corrected in further versions of network controllers The detector response was caused by a testing action such as im pact of a
64. e An addressable device has been found at the address during polling but this device is not programmed in the controller configuration Moreover in the bottom of the tab there are Request the Device Type switch at the left and Poll and Write button with circular green arrows on it at the right these tools being active if only the S2000 KDL is phvsicallv connected to the computer Request the Device Type If the flag is set on then in case of normal communication with the con troller over the RS 485 interface the UProg in real time periodically sends the S2000 www bolid com 86 S2000 KDL Programming KDL commands to poll addressable zones in order to find out tvpes of connected devic es The results of such polling are displaved in blue under each addressable zone in the second line If vou leave the Device Tvpe tab and select anv other tab of the UProg this flag will be automaticallv set off Poll and Write Clicking on this tool initiates polling all the addressable devices of the S2000 KDL connected to the computer with the UProg installed followed bv loading all the de vice types found at all addresses of the polling loop to the S2000 KDL s configuration displaving them just under the relevant zones of the controller in green In such case if before the polling the controller configuration included another device at some address the device tvpe will be replaced bv the new value found in polling There are two wavs to pr
65. e OOOO EN Switch On For a Time If an assigned input zone has just been armed the relay is switched on for a time given by the Relay Activation Time for gt Upon Arming this output Otherwise the relay is off If an assigned input zone has just been armed the relay is 20 Switch Off For a Time switched off for a time given bv the Relav Activation Time for Upon Arming this output Otherwise the relav is on If an assigned input zone has just been disarmed the relav 21 Switch On For a Time is switched on for a time given by the Relay Activation Time Upon Disarming for this output Otherwise the relay is off If an assigned input zone has just been disarmed the relay 22 Switch Off For a Time is switched off for a time given by the Relay Activation Time Upon Disarming for this output Otherwise the relay is on If arming one of assigned zones has failed the relay is 23 Switch On For a Time switched on for a time given by the Relay Activation Time for When Arming Failed this output Otherwise the relay is off If arming one of assigned zones has failed the relay is 24 Switch Off For a Time switched off for a time given by the Relay Activation Time for When Arming Failed this output Otherwise the relay is on If one of the assigned auxiliary zones is broken the relay is Switch On For a Time l e 25 Upon Auxiliary Zone Peu for a time given by the Relay Activation Time for Breaking Otherwise the relay is off If
66. e Sensi tivity Threshold preprogrammed for the zone The detector fails to measure temperature 30 S2000 KDL Operation Principles Zone Tvpe 10 Thermostatic This tvpe of zones provides using fire heat detectors as temperature meters and to create thermal control svstems The polling loop being in the quiescent mode the controller requests the digital values of temperature measured by the detector at its location point Arm and Disarm commands provide involving and ex cluding the zone from the thermostatic svstem respectivelv The following devices can be assigned to a zone of the Type 10 a analogue addressable fixed temperature and rate of rise detectors S2000 IP S2000 IP rev 01 and S2000 IP rev 02 used to measure temperature at the location point of the detector b S2000 VT combined temperature and humidity sensors temperature measurement channel Available statuses of a zone of the Type 10 are the following DISARMED The zone is monitored only for troubles the S2000 KDL neither analyses temperature values received from the device nor out puts messages about temperature increasing decreasing zone statuses don t affect thermal control process ARMING DELAY Delaying to use the zone in thermal control system operating TEMPERATURE LOW The measured temperature has dropped below the value of Temperature Decreased Threshold predetermined for the zone TEMPERATURE HIGH The measured temperature has exceeded the value of Tem
67. e two or more fire protection zones for each closed premises to monitor fire situation as well as one or more Auxiliarv zones to monitor door conditions These zones are linked with an addressable output as signed to the Discharge program After receiving fire alarms from one or more fire zones the S2000 KDL turns the relav output on for a time if all the doors are closed If a door is open the relav output will not be turned on until all the doors will be closed The program 33 Discharge 1 is similar to the program 11 Discharge but it is exe cuted just after receiving a fire alarm from a single linked zone The programs 34 Discharge A and 35 Discharge 1A are similar to programs 11 Discharge and 33 Discharge 1 The difference is that if one for 35 or two for 34 assigned zones has responded with fire alarms and the output has been turned on then the relay output turned off by breaking the auxiliary zone zones will not be turned on again upon recovering these ones Executive Program 12 Siren The program 12 is to be used when the output relay is supposed to control an external sound alarm Executive Program 13 Fire Output The program 13 is used when the output relay is supposed to transfer fire alarms to a fire brigade or central monitoring station Executive Program 14 Trouble Output The program 14 is used to monitor fire protection zones for proper operability The relay output assigned to
68. ected to the controller one at a time with assigning them to sequential addresses If two or more addressable devices within the polling loop have the same loop address 69 www bolid com SECURITV SVSTEMS Orion ISS the S2000 KDL cannot poll them properlv while the UProg tool cannot displav all the devices con nected to the S2000 KDL To ensure all the addressable devices are connected correctiv while commissioning use the device parameters request commands of the UProg see Section Requesting Parameters of Addressable Devices of this Manual WIRING THE RS 485 INTERFACE LINE Connect the S2000 KDL to the network controller via the RS 485 interface bus by doing the following 1 Couple the RS485A and RS485B terminals of the controller see Figure 2 and Figure 4 with A and B wires of the RS 485 bus respectively 2 Couple the GND circuits of the S2000 KDL and S2000 C2000M console as well as 0 V circuits of these devices you can ignore this requirement if both devices are powered by the same power supply 3 If the S2000 KDL is neither the first nor the last device within the RS 485 bus remove XP2 jumper located close to RS485A and RS485B contacts see Figure 2 which if put on includes an EOL resistor into the RS 485 interface bus Improper polarity of wiring the S2000 KDL to the RS 485 interface bus will cause commu nication loss between the S2000 KDL and the network controller CONNECTING POWER SUPPLIES One or two power supplies
69. en for each zone of the Type 15 Arm and Disarm commands cause respectively involving the zone into and its eliminating from operat ing of a humidity measurement and control system Available statuses of a zone of the Type 15 are the following DISARMED Only troubles are monitored Neither humidity is measured nor the zone affects humidity control ARMING DELAY Activating the zone is delayed until the Arming Delay time has elapsed LEVEL LOW The measured value of the humidity has dropped below the predetermined Humidity Decreased Threshold value LEVEL HIGH The measured value of the humidity has exceeded the prede termined Humidity Increased Threshold value LEVEL NORM The measured value of the humidity is within the range between the Humidity Decreased Threshold value and the Humidity In creased Threshold value TROUBLE The addressable device failed to measure temperature The following configuration parameters are to be set for a zone of the Type 15 see Table 1 Humidity Increased Threshold the value of relative humidity in at the place of S2000 VT location which causes the Zone to enter Level High status Humidity Decreased Threshold the value of relative humidity in 96 at the place of S2000 VT location which causes the Zone to enter Level Low status Arming Delay for a Humidity Measurement zone defines the time in seconds after elapsing which since receiving an Arm command the controller will request measured humidi
70. ensitivity Thresh ard units to respond with a Fire Alarm 80 100 90 old message for Night mode Prealarm Night The level of smoke in terms of stand Sensitivity ard units to respond with a 70 80 70 Threshold Fire Prealarm message for Night mode Als The level of dust in the smoke chamber Gontaminuo of the detector in terms of standard Threshold c with 10 60 50 for Type 8 units to respond with a Service Required message The value of temperature in C to re o o Fire Temperature spond with Fire Alarm message 54 C 85 C 54 Prealarm The value of temperature in C to re b Temperature spond with Fire Prealarm message BUENOS Temperatuig The value of temperature in C to re o o p spond with Temperature Low message o SAN DIO Threshold p p 9 Temperature WE un message 35 0 125 0 22 Threshold p p 9 9 Humiditv l Eu The value of relative humidity in 96 to Decreased 0 100 96 60 Threshold respond with Level Low message Humidity The value of relative humidity in 96 to ki increased respond with Level High message dau ds m Threshold B 9 9 0 Indication Disabled the S2000 TAM KDL disables device indication Device Indication Rc e l 0 2 4 Control 1 Standalone indication contro es 2 Controlling device indication by the S2000 KDL www bolid com 20 S2000 KDL Operation Principles Ero Factory Switches the addressable device to the energy save mode depending on the zone status for examp
71. ethods for their removal as well as preventive measures to be carried out during using the controller TROUBLESHOOTING Troubles of the S2000 KDL or its addressable system are indicated by the controlled LEDs as well as transmitted to the Orion system over the RS 485 interface Locally Indicated Troubles READY LED is not lit READY LED flashes with yellow twice per second RS 485 LED flashes with green yellow twice per second LOOP LED is not lit provided that the EN 54 Indication is off or LOOP LED is lit in yellow with short pauses once per second LOOP LED is lit steady with yellow www bolid com No supply voltage on the U1 and U2 terminals of the XT1 block Check the power supply supplies for proper operability and proper attachment of wires to the terminals Power supply voltage at one or both contacts U1 and U2 of the XT1 terminal block has dropped below 9 3 V Replace the faulty power supply supplies No communications between the S2000 KDL and the S2000 M console via the RS 485 port Inspect attachment of the wires of the RS 485 bus to the RS 485A and RS 485B terminals of the XT1 block of the S2000 KDL as well as operability of the con sole and attachment of the RS 485 bus wires to the relevant terminals of the console No connection with any addressable device in the polling loop of the S2000 KDL gt No communication with addressable devices programmed in the S2000 KDL config
72. f the zone The parameter Arm Disarm by Group provides simultaneous arming or disarming all the zones for which this parameter is set on using the command Group Arming Disarming The option is only val id for zones which are assigned to specific device types in the controller database The Alarm Delay parameter defines a time in seconds in which the controllers tries to arm the zone after generating relevant command Non zero alarm delay is used for intrusion zones for example for an entrance door in order a user to have some time to leave premises after arming the security sys tem The Save Mode parameter allows regulating power consumption of the addressable device depend ing on the status of the device s zone For detectors with microwave modules this parameter provides switching off the active element to reduce the impact of microwave radiation on people in the protect ed premises An addressable device is switched to the Save Mode on zone s entering the Disarmed status the parameter Disarmed Loop Monitoring being ignored Switching to the Save Mode is only provided for those addressable devices which sup e port this mode and the communication protocol DPLS v2 xx see manuals of addressa ble devices The Device Indication Control parameter defines the indication mode of the addressable device connected to the current input zone of the S2000 KDL The values of this parameter and the relevant indication modes can be as
73. face bus and adjust pa rameters of communicating data between the S2000 KDL and the network controller Program the own controller parameters and parameters of the external reader if used Program the loop addresses of connected addressable devices and enroll the devices into the controller database Define the relevant monitoring tactics for all input addressable zones Define the relevant control tactics for all the output zones optionally Register user s electronic kevs authenticators for local arming disarming if applicable VW ON ON Measure electrical parameters of the polling loop and ADC values of addressable devices while commissioning The S2000 KDL and its addressable system is programmed by means of the UProg Configuration Tool the tool for programming Orion system devices installed on the PC connected to the S2000 KDL A number of settings such as programming the S2000 KDL s network address and loop addresses of addressable devices can be done also by means of programming tools of the network controller S2000 KDL settings are stored in its non volatile memory S2000 KDL ADDRESS SPACE ALLOCATION Address space of the S2000 KDL polling loop consist of 127 logic addresses numbers which can be assigned to connected addressable devices Each addressable device in the polling loop has to have a unique address in the polling loop the so called loop address As a rule addressable devices connectable to the polling
74. follows www bolid com 22 S2000 KDL Operation Principles 0 Indication Disabled the S2000 KDL disables device indication 1 The LED of the addressable device indicates statuses of the addressable device and the parameter monitored by the device according to own pre programmed tactics of the device as described in the device specification 2 LED indication is controlled by a S2000 KDLlogic and shows zone statuses see Sec tion Light Indication of Addressable Devices of this Manual Controlling the LED is only provided for those addressable devices which support the communication protocol DPLS v2 xx see manuals of addressable devices To provide controlling LEDs of conventional detector from third partv manufacturers inter face them in the polling loop through the input modules S2000 AR1 rev 04 Zone Tvpe 1 Smoke Fire A zone of Tvpe 1 is designed to monitor photoelectric smoke detectors DIP 34A operated in thresh old addressable mode returning the controller fire alarm statuses when the smoke level measured bv the detector exceeds the internal threshold of the detector Available statuses of a zone of the Type 1 are the following ARMED DISARMED ARMING DELAV ARMING FAILED FIRE ALARM OPEN FAILURE TROUBLE SERVICE REQUIRED Zone Tvpe 2 Combined Fire The zone is fullv monitored The zone is in norm if there is no faults Arming the zone is delaved until the Arming Delav time has e
75. g on the current zone status all the zones assigned to this key If the zone status is not Disarmed presenting the electronic key will cause trying to disarm the zone Otherwise the controller will give a command to arm the zone For 2s since second presenting the electronic key the reader is indicating a new status of zones If the electronic key is presented again to the reader for this 20 s zones status will be changed in ac cordance with the algorithm described before and a time interval of 20 s will be being counted once more On expiration of this time the reader exits the mode of reading electronic keys its LED and sounder being off 49 www bolid com SEGURITV SVSTEMS Orion ISS Centralized Control in the Orion Svstem If an electronic key presented on the S2000 KDL reader is not registered in the S2000 KDL memory the controller operates the kev in the mode of centralized control If the communications between the S2000 KDL and the network controller over the RS 485 interface is lost at the time the controller generates and puts in its buffer a message about rejecting access in dicating the event by readers LED and sounder see Section Light and Sound Indication of the Read erof this Manual If the S2000 KDL communicates with the network controller normally it transfers the network control ler the request for rights of this kev to control partitions and all further operations follow the rules de scribed in the Manual fo
76. ge programmed for an output assigned with this zone in the S2000 KDL configuration the controller activates the output as defined bv its predetermined executive program The controller also trans mits the changed output status to the network controller if the relevant switch in the out put s settings allows that see Section Configuration Parameters of Addressable Out puts Zone Type 11 Panic A zone of the Type 11 Panic zone realizes a tactics of hidden alarms when the controller having received a detector alarm response generate a special message Silent Alarm but neither light nor sound alarms are tuned on The following devices can be monitored as zones of the Type 11 a b c d S2000 KT Addressable Panic Button or Addressable input modules interfaced various panic buttons and pedals or S2000 SMK and S2000 SMK Estet Addressable Magnetic Contacts LEM Ex rev 02 Loop Expansion Module interfaced intrinsically safe alarm loops Available statuses of a zone of the Type 11 are the following ARMED The zone is fully monitored DISARMED The zone is in a norm the Disarmed Loop Monitoring parameter being set on the addressable device enclosure is closed the TAM PER contacts of the S2000 AR1 is closed there is no faults TAMPER ALARM The enclosure of the addressable detector or input module being in statuses Disarmed or Arming Failed or Arming Delav is open NOT READV TO ARM The zone has been broken the Dis
77. guring Orion system devices Over RS 485 interface bus via one of the Bolid manufac tured interface converters PI GR S2000 PI S2000 USB or USB RS485 13 www bolid com SEGURITV SVSTEMS Orion ISS www bolid com 14 S2000 KDL Operation Principles OPERATION PRINCIPLES 15 www bolid com SEGURITV SVSTEMS Orion ISS MULTIPLEX ADDRESSABLE POLLING LOOP OF THE S2000 KDL Two wire addressable polling loop of the S2000 KDL is designed to communicate data with 127 ad dressable zones with each zone being configured depending on the kind of connected addressable device either as gt An Input Zone which can be phvsicallv represented bv an addressable fire or intrusion detec tor or call point monitored circuit of an addressable input module temperature humiditv sensor monitored circuit of a consumption meter S2000 ASR2 and so on or gt An Output which can be represented by a S2000 SP2 relay output or virtual output of a LEM Ex rev 2 and so on The addressable polling loop can operate in one of two available modes gt Initialization or gt Quiescent Poll After starting powering the controller or internal reset the polling loop of the S2000 KDL enters the Initialization mode In such mode the controller starts powering addressable devices and gathering information about programmed and actually connected addressable devices Gathering information the controller requests types of devices around the entire address range
78. h the number 1 for example DL1 for an S2000 AR2 The second circuit for example DL2 for an S2000 AR2 is automatically assigned to an incremented number For an S2000 AR8 the address specified in the command as a parameter max imum 120 will be assigned to the DL1 while addresses of other circuits device loops will be auto matically assigned sequentially in ascending order 77 www bolid com SECURITV SVSTEMS Orion ISS If programming the address of the addressable device has completed successfully or 10 minutes has elapsed since entering the program mode then the device exits programming mode To force S2000 KDL s exiting the mode of programming addressable devices a relevant command should be sent Upon changing the loop address of an addressable device connected to the S2000 KDL the known current address of the device is replaced by the given address Changing device addresses is performed by Change Device Address commands sent by the S2000 S2000M console In such a command both addresses old and new are specified If the ad dress has been changed the controller sends a Success message If the address of a missing ad dressable device is specified in the command as an old address the controller sends a message about missing the device with given address For the devices occupying more than a single address within the polling loop changing an address specify the least of all addresses to be assigned The next adjacent addresses wi
79. he specified time since receiving the Arm command This time is for leaving the pro tected premises For Auxiliarv zones zones of the Type 6 receiving an Arm Disarm command causes the control ler to generate a message about the current zone status A zone of the Type 10 having been armed is involved into a programmed temperature control mechanism If the value of temperature measured by the detector is out of the thresholds programmed for the zone the controller generates a TEMPERATURE LOW or TEMPERATURE HIGH message The temperature having returned to a normal range the S2000 KDL generates a TEMPERATURE NORM message If the zone is related to a controller addressable output in the S2000 KDL configuration then the tem perature s being out of the normal range programmed for this output causes the output to be activat ed If a Disarm command is given for a zone of the Type 10 automatic analyzing the temperature re ceived from the addressable detector is stopped but the temperature can however be measured by a remote request from the network controller or UProg software tool see Section Hequesting Parame ters of Addressable Devices of this Manual A zone of the Type 15 having been armed is involved into a programmed humidity control mecha nism If the humidity value measured by the detector is out of the thresholds programmed for the zone the controller generates a LEVEL LOW or LEVEL HIGH message The humidity havi
80. igure 5 Ring Topology of the Polling Loop 2000 a 033 D H BRIZ HD D l BRIZ Figure 6 Tree Topology of the Polling Loop 67 www bolid com SEGURITV SVSTEMS Orion ISS ar BRIZ BRIZ s2000 _ KDL LreRz D BRIZ Figure 7 Mixed Topology of the Polling Loop The Number of the Addressable Devices to Be Connected The number of addressable devices which can be brought into the polling loop of the S2000 KDL de pends on two factors 1 Total current consumption of the devices connected to the polling loop which should not exceed 100 milliamp current consumption of each addressable device should be specified in its manual and also The way the loop addresses of addressable devices are distributed in the address space of the polling loop some devices occupy two or more adjacent addresses see documentation of the addressable devices and should be positioned in the address space in a certain way The maximum number of addressable devices in the polling loop is 127 Length of the Polling Loop The maximum length of a polling loop branch is to be estimated by the following algorithm 1 3 Estimate the total current consumption of all the addressable devices which are to be brought to the polling loop branch current consumption values of addressable devices are specified in their manuals Given th
81. ing In state of running a self diagnostic procedure see Section Preventive Maintenance indicators READY RS 485 and LOOP shall flash with long pauses one by one Table 6 READY LED Behavior Conditions of S2000 KDL Power Inputs in state of Both Power Inputs Both Power Inputs LED Behavior Monitoring being on Monitoring being off The power supply voltage at The power supply voltage at the both input terminals input terminal Lit steady in green U1 and U2 is above 9 8 V U1 or U2 is above 9 8 V The power supply voltage at The power supply voltage at the input terminal both input terminals U1 or U2 is below 9 3 V U1 and U2 is below 9 3 V Flashes in yellow twice per second Both Power Inputs Monitoring is turned on just on turning on EN 54 Indication 51 www bolid com BOLID SECURITY SYSTEMS Orion ISS Table 7 RS 485 LED Behavior Communication conditions er m at the RS 485 port EN 54 Indication Is Off EN 54 Indication Is On Regular communications Lit steady in green Off at the RS 485 port Flashes with yellow No communications Flashes with green twice per second at the RS 485 port twice per second Table 8 LOOP LED Behavior Polling Loop Condition EN 54 Indication Is Off EN 54 Indication Is On Lit in yellow with short No connection with pauses once per second addressable devices Stable communication with all phys Lit steady in green Off ically connected devices No co
82. inked with one or more local zones of the Types 10 or 15 which sensors measuring relevant physical quantity is connected to Also for each the output threshold values of measured value shall be specified a Temperature Humidity Increased Threshold and Temperature Humidity Decreased Threshold For the executive program 36 an assigned output is activated when the value of physical quantity measured at the zone linked with the output exceeds programmed Tempera ture Humidity Increased Threshold the output being turned off when the measured value drops below Temperature Humidity Decreased Threshold For the executive program 37 on the contrary the output is activated when the meas ured value drops below Temperature Humidity Decreased Threshold the output be ing off when the measured value exceeds Temperature Humidity Increased Thresh old The outputs of the S2000 KDL controlled in accordance with the programs 36 and 37 cab be turned on either in continuous or in pulse mode The actual mode of executing programs is regulated by the value of Activation Delay programmed for the outputs which has a special meaning for the programs 36 and 37 If the Activation Delay parameter is set to 0 the output will be switched on for unlimited time as long as the condition for its activation is true without regard to the given value of the Relay Activation Time parameter If the Activation Delay parameter is not equal to 0 the output wil
83. ith the specified zone address is generated for An analog addressable smoke detector zone of the Type 48 if the Contamination Threshold programmed for the zone has been exceeded for at least two hours or gt An addressable smoke detector zone of the Type 1 or 2 if the internal contamination threshold of the detector has been exceeded Having received this message clean the smoke chamber of the detector A failure of the sensor or the measuring channel of the addressa ble detector temperature and humidity sensor or consumption meter The power supply voltage on one or both terminals U1 and or U2 of the XT1 terminal block has dropped below 9 3 V Replace the improper power supply supplies An open circuit failure in the addressable zone A short circuit failure in the addressable zone the resistance value is less than 100 Q No communication between the addressable device and the con troller by the branch 1 of the polling loop No communication between the addressable device and the con troller by the branch 2 of the polling loop Short circuit failure in the polling loop in the branch 1 branch 2 A trouble of the polling loop voltage in the loop branch 1 branch 2 exceeds the level generated by output circuits of the S2000 KDL 114 S2000 KDL Maintenance PREVENTIVE MAINTENANCE To make sure the S2000 KDL keeps proper operabilitv it shall be inspected by a competent specialist at least on receipt and
84. ivation Delay Defines the time interval to delay starting an executive program after realizing its condition suitable for executive programs 1 to 8 11 12 17 to 35 O s to 8192 s 2 h 16 min 32 s in increments of 0 125 s And Or Logic The algorithm for starting stopping executive programs 36 and 37 if the output is linked with several input zones of Types 10 or 15 0 Or 1 And Temperature Increased Threshold Given for programs 36 and 37 this parameter defines the temperature value which cause relay switching on 36 or switching off 37 55 C 125 C Temperature Decreased Threshold Given for programs 36 and 37 this parameter defines the temperature value which cause relay switching off 36 or switching on 37 55 C 125 C Humidity Increased Threshold Given for programs 36 and 37 this parameter defines the humidity value which cause relay switching on 36 or switching off 37 Humidity Decreased Threshold Given for programs 36 and 37 this parameter defines the humidity value which cause relay switching off 36 or switching on 37 Notify on Changing Relay Statuses Enables or disables generating Relay Status Changed messages cussing these programs see below 39 Yes No For the executive programs 36 and 37 the sense of this parameter will be described while dis www bolid com SEGURITV SVSTE
85. iving will cause turning off the output for the program 36 and turning on the output for the program 37 The Temperature Decreased Threshold can be defined for each output separately in the range of 55 C to 125 C By default its value is equal to 20 C DO NOT confuse the increased decreased thresholds defined for relay outputs with the same thresholds defined for input addressable zones of the poling loop Humiditv Increased Threshold This setting defines the value of ambient relative humiditv measured by the humidity sensor of the S2000 VT in the assigned addressable zone of the S2000 KDL which receiving will cause turning on the output for the program 36 and turning off the output for the program 37 The Humiditv Increased Threshold can be defined for each output separatelv in the range of 0 96 to 100 By default its value is equal to 70 Humidity Decreased Threshold This setting defines the value of ambient relative humidity measured by the humidity sensor of the S2000 VT in the assigned addressable zone of the S2000 KDL which receiving will cause turning off the output for the program 36 and turning on the output for the program 37 The Humiditv Decreased Threshold can be defined for each output separately in the range of 0 96 to 100 By default its value is equal to 60 www bolid com 102 S2000 KDL Programming Programming Access Groups Access Groups are used within an Orion svstem in order to give users
86. l 1 active or Forward Polaritv to turn the sounder of the reader on Reverse 1 active 0 active Enables and disables sounding for the On Off On reader Sounding Enabled Gives the maximum number of digits in a Maximum PIN code for readers with Wiegand out PIN Code Length put interface transferred the controller digits of PIN codes one by one Disabled Allows temporary locking for the key On Off Defines control access rights for the key as Access Group Local Controlling Input Zones of the S2000 KDL If an electronic key presented to the reader of the S2000 KDL is registered in the controller memory the controller operates the key in the mode of local control If the key is locked in the S2000 KDL configuration the controller generates an Access Denied mes sage indicating the event see Section Light and Sound Indication of the Reader and transferring the message over the RS 485 interface If the Disabled key attribute is set off after presenting the electronic key the LED and sounder of the reader will indicate an integrated status of the zones assigned to this key by its access group see Section Light and Sound Indication of the Reader of this Manual The S2000 KDL generates and transfers the network controller a User s Code Entered message After that second presenting of the electronic key is expected for some time Second presenting of the electronic key is performed to arm or disarm dependin
87. l be switched on periodi cally for a time given by Relay Activation Time with pauses between turnings on equal to programmed Activation Delay If an addressable output of the S2000 KDL is assigned to several zones of the Types 10 or 15 it is necessary to define whether the output will be switched on when the control condition is true at least for one linked zone or the output will be switched on when values measured in all zones linked to the output must be out of a permissible range For doing so And Or Logic parameter must be set to the relevant value for the output www bolid com 46 S2000 KDL Operation Principles e DO NOT confuse the Temperature Increased Decreased thresholds defined for an S2000 KDL output and similar named thresholds programmed for Thermostatic or Hu midity Measurement zones see Section Zone s Configuration Parameters Returned temperature or humidity value s being out of the range programmed for a Thermostatic or Humidity Measurement zone causes the S2000 KDL to switch the zone to the Temperature Level High Low status and to transmit the relevant message to the network controller If on the contrary measured temperature or humidity values are out of the range pro grammed for an output assigned with this zone in the S2000 KDL configuration the con troller activates the output as defined by its predetermined executive program The con troller also transmits the changed output status to the network co
88. lapsed The parameter monitored bv the addressable device is out of normal range at the time of arming the zone The DIP 34A has detected smoke levels exceeding its own sensitivitv threshold see Table 2 The DIP 34A fails to measure smoke level A contamination self compensation threshold for the smoke chamber of the DIP 34A has been exceeded Zones of the Type 2 are expected to monitor statuses of the addressable input modules S2000 AR2 S2000 AR8 and loop expansion modules LEM Ex rev 2 providing sensing such statuses of monitored circuits as Norm Fire Alarm Open Failure and Short Failure Available statuses of a zone of the Type 2 are the following 23 www bolid com SECURITY SYSTEMS ARMED DISARMED ARMING DELAY ARMING FAILED FIRE ALARM OPEN FAILURE SHORT FAILURE elapsed see Table 2 see Table 2 see Table 2 The zone is fully monitored The zone is in norm ifthere is no faults normal range at the time of arming the zone Orion ISS Arming the zone is delaved until the Arming Delav time has The parameter monitored bv the addressable device is out of Table 2 How the S2000 KDL Interprets Statuses of the Input Modules Monitored Circuits Available Statuses of Monitored Circuits Alarm Open Failure Open Failure Open Failure Short Failure Fire Alarm Tamper Alarm Fire Alarm Open Failure Short Failure Short Failure Fire Alarm Short Failure In
89. le in the Disarmed status Save Mode On Off For the zone of the Type 13 this is the Counting number of pulses which are to accumu Threshold lated by the S2000 ASR2 until this number will be sent to the S2000 KDL 0 65535 For the zone of the Type 13 this is the Counter Integral integral action time for filtering in moni Action Time tored circuits noises with frequency more than frequency of counted pulses 0 5 ms 127 5 ms Night to Day The time when the Night operating Threshold mode of the detector is turned off while 00 00 23 59 for Type 8 the Day mode is turned on HH MM Day to Night The time when the Day operating mode Threshold of the detector is turned off while the 00 00 23 59 for Type 8 Night mode is turned on HH MM The main configuration parameter of each zone which defines tactics of its monitoring and available kinds of monitored devices is Zone Type The S2000 KDL supports the following types of zones of different functionality Fire 1 Smoke Fire 2 Combined Fire 3 Heat Fire 8 Smoke Analogue With Programmable Thresholds 9 Heat Analogue With Programmable Thresholds Intrusion 4 Intrusion 5 Intrusion With Tamper Check 7 Entrance 11 Panic Auxiliary 6 Auxiliary 10 Thermostatic 13 Counting 15 Humidity Measurement All types of zones along with their specific parameters will be considered in following Sections Here we
90. ll be assigned to monitored circuits of the device successivelv in ascending order www bolid com 78 S2000 KDL Programming PROGRAMMING ADDRESS SVSTEM OF THE S2000 KDL BV MEANS OF UPROG To program the S2000 KDL and its polling loop the Orion devices configuration tool the UProg is in tended This program is installed on a PC connected to the S2000 KDL via one of the Bolid manufac tured interface converters such as PI GR S2000 PI S2000 USB or USB RS485 The last version of the UProg exe as well as additional information about using the S2000 KDL are available in the Internet at the address of www bolid com UProg Interface After running the UProg its working window is opened on the PC display At the top part of the window there are the Main Menu and the Toolbar Select the Device Read Device Configuration command or press lt Ctrl F3 gt or select the icon from the toolbar The Device Search window will be output on the display Specify the number of the logic COM port the S2000 KDL is connected to and the UProg will start searching the devices connected to this COM port of the PC Then the list of all found devices with their network addresses and version numbers will be shown at the display Select the entry for the S2000 KDL and press the Select button The UProg will display the window with the controller settings located on several tabs see Figure 12 UPROG Configuration Tool for S2000 KDL version 1 46 File De
91. llers verifies correspondence between types of the device programmed for each addressable zone and devices physically connected at the zones In case of mismatch the S2000 KDL output a Zone Con figuration Error message On the Device Type tab of the UProg see Figure 14 the address space of the polling loop is visual ized schematically with already programmed or vacant addresses Addressable zones are seen as circles with loop addresses in its centers The captions below the circles show types of devices pro grammed for each zone or Not Connected if the zone has not yet been programmed If the configuration is loaded to the UProg from the memory of the controller which is connected to the PC at the time then captures below circles denote devices which are found bv the S2000 KDL as a result of controller s polling the loop or Not Connected if no device was found at the address The color of the circles displavs the correspondence between zone settings and reallv connected ad dressable devices Grev A vacant addressable zone the addressable zone is neither programmed nor connected Green The type of a really connected device matches the type of the device programmed in the database of the S2000 KDL Red The tvpe of a reallv connected device doesn t match the tvpe of the device programmed in the database of the S2000 KDL Yellow An addressable device is programmed at the address but the device is not recognized dur ing polling Blu
92. loop are supposed to have a single loop address and can be allocated within the address space of the polling loop arbitrary However a number of devices namely S2000 AR2 S2000 ASR2 and S2000 SP2 if the last pro grammed to connect two executive devices occupy two adjacent loop addresses within the polling loop An S2000 AR8 addressable eight input module occupies eight adjacent loop addresses in the S2000 KDL address space www bolid com 76 S2000 KDL Programming PROGRAMMING ADDRESSES OF DEVICES CONNECTED TO THE POOLING LOOP Most of addressable devices connectable to the polling loop stores their loop addresses in their non volatile memories these devices being programmed either bv means of the network controller s tools or with the help of the UProg Configuration Tool see below Some devices such as S2000 SP2 executive modules and S2000 IK rev 02 addressable detectors require programming their addresses manuallv bv means of their DIP switches located on their print ed circuit boards To avoid conflicts and confusions while allocating address space we advise vou to connect these devices and enroll them into the controller memorv one bv one before mounting The procedures of programming loop addresses of the addressable devices are described in details in devices specifications Programming Changing Device Loop Numbers bv Network Controller Tools Programming loop addresses with the help of the network controller is required onl
93. magnet or laser pointer The text of this message is obso lete and is to be corrected for next versions of network controllers The polling loop is switched to the Detector Test Mode see section Remote Controlling the S2000 KDL over the RS 485 of this Manual The text of this message is obsolete and is to be corrected for next versions of network controllers The polling loop exits the Detector Test Mode see section Hemote Controlling the S2000 KDL over the RS 485 of this Manual The text of this message is obsolete and is to be corrected for next versions of network controllers The zone is disarmed but cannot be armed due to detector s being activated The zone is disarmed and ready for arming The auxiliary zone has been broken The auxiliary zone has been restored The temperature in the thermostatic zone has exceeded a specified upper threshold The temperature in the thermostatic zone has been in a normal range The temperature in the thermostatic zone has dropped below a specified lower threshold The humidity value in the humidity measurement zone has exceed ed a specified upper threshold The humidity value in the humidity measurement zone is in a speci fied normal range The humidity value in the humidity measurement zone has dropped below a predetermined lower limit Communications between the S2000 KDL and the addressable re lay module has been lost 58 S2000 KDL Operation Principles RELAV CONNECTED RELAV
94. mmed controller 2 If readers with different data formats are used in the svstem then adding personal to the Orion database enroll their codes in all available formats that is assign a user to so many descriptors which the number of used incompatible data format is www bolid com 50 S2000 KDL Operation Principles LIGHT AND SOUND INDICATION S2000 KDL Light Alarms The S2000 KDL provides indication of its conditions bv means of three two color LEDs located on its faceplate gt READY LED indicates power conditions of the controller gt RS 485 LED displays communication conditions between the S2000 KDL and the network con troller if applicably over the RS 485 interface gt LOOP LED indicates conditions of the polling loop and communication between the controller and its addressable devices as well as displays processes in the polling loop such polling the ad dressable devices and programming their loop addresses The method of LED indication depends on current setting of the controllers configuration option EN 54 Indication If the option is on the indication algorithm fulfills the European standards EN 54 2 while otherwise this one is set off the S2000 KDL implements its own indication algorithm In addition condition indication also depends on current settings of the configuration option Power Input Monitoring and Ring Topology see below Table 6 Table 7 and Table 8 describe indication of the controller during operat
95. mmunication with addressable devices programmed in the S2000 KDL configuration Lit steady with yellow Lit steady with yellow One or more addressable devices are in Error Response or Unstable Communication status Flashes in yellow Flashes in yellow twice per second A short circuit failure or other twice per second trouble in the loop Flashes in yellow Flashes in green four times per second Polling all zones after starting pow four times per second ered the controller Double flashes with yellow Double flashes with green with a long pauses with a long pauses Programming a loop address for the device with non volatile memory Lit steady with green with NA Flashes in yellow flashing in yellow once per once per second second The Ring Topology option is set on and communications at PL1 or PL2 is lost www bolid com 52 S2000 KDL Operation Principles Light Indication of Addressable Devices Addressable devices operated under S2000 KDL control perform their light indication according to own predetermined algorithms which are described in documentation of these devices However for the addressable devices which support the communication protocol DPLS v2 xx the S2000 KDL provides two additional indication options namelv Indication Disabled and Controlled by the S2000 KDL The current mode of indication of addressable devices supporting DPLS v2 xx is defined by the De vice Indication
96. mperature Prealarm Temperature Temperature Decreased Threshold Temperature Increased Threshold Device Indication Control Save Mode Counting Threshold Counter Integral Action Time ms Humidity Increased Threshold Humidity Decreased Threshold a Link the relay to the zone 1 DIP34A 01 02 v 1 20 1 2 3 4 5 6 7 8 Enter numbers of zones which current parameters are to be applied to For Lew example 1 2 13 18 Copy only the current setting Copy input to output matching Device Type Zones Dutputs Figure 15 Programming Input Addressable Zones of the S2000 KDL www bolid com 90 S2000 KDL Programming In the columns of the upper window of the Zones tab there are descriptors of all input zones already programmed on the Device Tvpe tab In the bottom window links of the selected zone selected col umn with outputs relavs of the S2000 KDL is shown The output selected in blue which is linked to the selected zone its number and name of the assigned addressable device are shown above the zone map is marked with the character Setting the Descriptors of Input Addressable Zones The options which should be programmed for each input addressable zone of the S2000 KDL are as follows Zone Tvpe The main parameter defining the S2000 KDL s monitoring tactics for each input zone of the polling loop see Section Input Zones of the Polling Loop of this Manual A Zone Type must match the tvpe of the add
97. n Value S2000 AR2 Request the Device Voltage S2000 ARS S2000 AR8 S2000 AR8 22000 A5R2 Not Connected S2000 IK 52000 IK DIP S2000 IP 52000 KT Not Connectel SRODQINIWE S2000 PIK 52000 PIK ST S2000 SHIK 52000 5MK S2000 PIK v 1 00 Not Connecte gt 2000 5MK ESTET Not Connected S2000 SP2 52000 5P4 52000 5T 52000 STIK IK Not Connected Not Connecte gt 2000 STIK ST Not Connected 52000 V M w S2000 VTV Request the Device Type S2000 VT T Programmed and real types match J The programmed device is not found me e Programmed and real tppes mismatch An unknown device is found x Enter numbers of zones which current parameters are to be applied to For Copy 13 example 1 2 13 18 Copy only the current setting Copy input to output matching pe Figure 14 Programming Tvpes of Addressable Devices in the Polling Loop 85 www bolid com SEGURITV SVSTEMS Orion ISS Here vou can gt Define tvpes of addressable devices connected to each addressable zone of the polling loop gt Load loop addresses of addressable devices to their non volatile memory gt Request parameters of addressable devices supporting communication protocol DPLS_v2 xx Registering Addressable Devices Connected to the Polling Loop Addressable devices connected to the polling loop of the S2000 KDL must be enrolled in the control ler configuration with specifying their loop addresses and their types While operating the contro
98. ng loop are expected to cause outputs of the polling loop to be activated that is a tactics of automatic local control by events in the zone is defined it is neces sary to link the zone with those relay output outputs which an executive program will be run for If the link has not yet been programmed on the Outputs tab of the UProg see Section Programming Adaressable Outputs of the S2000 KDL of this Manual then left click on those relays marked in green on the zone map which are to be linked to the zone being programmed In our example Figure 15 the zone 1 selected in the upper window is linked to the output 20 marked in blue in the bottom window This means that in case of operating at this zone DIP 34A s having entered some status defined by the executive program given for the output 20 the output will be activated with implementing all details specified for this one see Section Programming Addressa ble Outputs of the S2000 KDL of this Manual 97 www bolid com SEGURITV SVSTEMS Orion ISS Copving Settings of Input Addressable Zones UProg provides copving input addressable zone settings to facilitate configuring the S2000 KDL To copv settings of a current input zone of the polling loop to descriptors of other zones enter the num bers of these zones into the right bottom dialog box on the Zones tab Figure 15 and click Copy If you need to copy a single parameter rather than all zone settings select this parameter of
99. ng returned to a normal range the S2000 KDL generates a LEVEL NORM message If the zone is related to a controller addressable output in the S2000 KDL configuration then the hu miditv value s being out of the normal range programmed for this output causes the output to be acti vated If a Disarm command is given for a zone of the Type 15 automatic analyzing the humidity values received from the addressable detector is stopped but the humidity can however be measured by a remote request from the network controller or UProg software tool see Section Requesting Parame ters of Addressable Devices of this Manual Arm Disarm commands are ignored for zones of the Type 13 www bolid com 36 S2000 KDL Operation Principles Detector s Operating within the Polling Loop Upon breaking a zone of the Type 4 or 5 which is armed for example upon receiving an intruder detector s response or tampering the detector enclosure the S2000 KDL switches the zone to the Intrusion Alarm status Also the relevant message is transmitted over the RS 485 interface Upon breaking a zone of the Type 7 the Entrance Alarm message is output and the Alarm Delay starts to be counted If the zone is not disarmed or armed within this time it enters the Intrusion Alarm status Upon receiving alarm responses from a zone of the Type 1 2 or 3 fire detection zones the con troller switches the zone to the Fire Alarm status and transmits the relevant message o
100. ning the sounder on is performed by outputting high logic level on the BEEP contact If otherwise the Reverse polarity is selected turning the sounder on is performed by outputting low logic level The forward polarity is set by default If neces sary change this setting by selecting the proper polarity from the relevant dropdown list Enable Sounding The option which enables the reader connected to the S2000 KDL to issue sound signals on by default Maximum PIN Code Length This parameter is to be programmed for such readers as keypads with Wiegand output inter face which sends the controller the digit one by one as a PIN code is being entered The PIN code is considered to be completely entered when the number of entered characters has reached the programmed value The number of PIN code digits can be given in the range of 1 to 12 by default the PIN code length is equal to 6 digits www bolid com 84 S2000 KDL Programmin Working with Addressable Devices Connected to the Polling Loop You can work with addressable devices connected to the polling loop of the S2000 KDL by using the Device Tvpe tab of the UProg see Figure 14 UPROG Configuration Tool for S2000 KDL version 1 46 File Device Help 4 e H DIP34A Device Type Not Connected X Not Connected Verify Device Type Unknown Device I es E DIP 344 IPR 513 34 LEM EX rev 02 LEM EX rey 02 SP v1 00 52000 AR8 S2000 AR1 S2000 AR1 rev 04 Request the Contaminatio
101. ntroller if the relevant switch in the output s settings allows that see Section Configuration Parameters of Ad dressable Outputs 47 www bolid com SEGURITV SVSTEMS Orion ISS CONTROLLING S2000 KDL INPUT ZONES AND USER AUTHORIZATION Local controlling input addressable zones of the controller such as requesting zone statuses arming zones disarming zones is only available for authorized users which have presented their authenti cators or electronic kevs To read electronic kevs which can be Dallas iButton access devices Prox imitv cards or digital PIN codes entered bv kevpads a reader with output interface Touch Memorv or Wiegand is connected to the S2000 KDL Authenticators used for local control must be enrolled in the controller memorv Apart from the elec tronic code the S2000 KDL stores two parameters for each registered electronic key which are an access group and a Disabled flag The access group of an electronic kev more exactiv the local ac cess group of the electronic key for this controller defines which addressable zones of the S2000 KDL a user presented the kev can control to The Disabled flag is set on for a kev in the case if zone control is temporarilv prohibited for the kev for example if the kev is lost Authenticators presented by users can be registered not in the memory of the S2000 KDL but in the memory of the network controller under which the S2000 KDL operates either S2000 S2000M con sole or O
102. ode Access Groups Disabled Number of Keys 0 The maximum possible number of keys 512 Reader s Device Address Reader Number Figure 18 Programming electronic keys in the UProg Keys tab of the UProg has its own toolbar Export Key Codes This tool enables writing all the keys listed at the left part of the win dow to a text file or MS Word file If keys are written to an MS Word file the keys are written along with all programmed attributes while if keys are written to a text file only key codes names and order number in the list are recorded Read Keys from File This tool works like the similar File menu command The com mand enables loading to the UProg exe key codes and attributes from a storage medi um in order to change their descriptors and or load them to the controller memory Save Keys to File This tool works like the similarly command from the File menu The command enables writing codes and attributes of the keys displayed at the left of the window to a special file to any storage medium This file then can be used to facilitate adjusting other controllers Read Keys from Memory The tool provides loading to the UProg exe the list of keys which are stored in the memory of the S2000 KDL connected currently to the PC Write Keys to Memory The tool enables writing all key codes and attributes shown at the left part of the window to the memory of the S2000 KDL connected to the PC
103. of 0 C to 81 C To set or change the value of the threshold double click by the left mouse button on the relevant box and type a proper val ue or select the value by arrow buttons Temperature Decreased Threshold This option is to be set for zones of the Type 10 representing the value of ambient tempera ture in C measured by an S2000 IP detector or S2000 VT sensor upon having dropped to which the S2000 KDL generates a message Low Temperature for this zone By default the threshold value is equal to 20 C and can be changed in the range of 55 C to 125 C To set or change the value of the threshold double click by the left mouse button on the relevant box and type a proper value or select the value by arrow buttons Temperature Increased Threshold This option is to be set for zones of the Type 10 representing the value of ambient tempera ture in C measured by an S2000 IP detector or S2000 VT sensor upon having reached which the S2000 KDL generates a message High Temperature for this zone By default the thresh old value is equal to 22 C and can be changed in the range of 55 C to 125 C To set or change the value of the threshold double click by the left mouse button on the relevant box and type a proper value or select the value by arrow buttons 95 www bolid com SEGURITV SVSTEMS Orion ISS DO NOT contuse the increased decreased thresholds defined for Thermostatic zones of the polling loop with the same th
104. of 12 V or 24 V can be connected to the S2000 KDL We recommend you to use Bolid manufactured power supplies of RIP series Connect power supplies to the pairs of con tacts GND U1 and GND U2 of the XT1 terminal block see Figure 2 In case of supplying power to the power input contacts of the operable S2000 KDL the green READY LED on the S2000 KDL faceplate shall turn on CONNECTING A READER An external ID reader with Touch Memory or Wiegand output interface can be connected to the rele vant contacts of the S2000 kDL see Figure 4 These contacts are described by Table 12 i If the reader is equipped with a single LED then despite of its color connect the LED control circuit to the LEDG terminal of the XT1 terminal block see Figure 2 www bolid com 70 S2000 KDL Installation If input voltage of the reader is within a range of controller output voltages and the distance between the reader and the S2000 KDL doesn t exceed 50 meters the reader power inputs can be connected directly to the U terminal of the controller see Figure 9 and Figure 10 Table 12 Input Terminals to Connect a Reader to the S2000 KDL Reader input voltage U Output positive wire TM Mode Input Output Reader data circuit Wiegand Mode Input Reader DO data circuit Reader input voltage GND Output negative wire TM Mode Unused Wiegand Mode LEDR Reader red LED control circuit Reader D1 data circuit LED
105. of keys but is stored in the controller memory and can be easily restored To delete all keys physically from the S2000 KDL memory select the E button from the toolbar at the Keys tab The deleted key cannot be restored In order to delete any key descriptor from the list of keys to mark the key as deleted select this key in the list and click on the BI button If the Show Deleted Kevs switch is set on the but ton is sunken then the descriptors of deleted kevs are shown with grev text otherwise the deleted kevs are hidden In order to restore a deleted kev select it in the list of kevs the Show Deleted Kevs switch must be set on and click on the el button www bolid com 108 S2000 KDL Programmin Managing the List of Kevs UProg Configuration Tool offers some additional utilities to handle kevs The list of kevs can be exported to a textual file or MS Word file bv means of the LER IH button If keys are written to an MS Word file the keys are written along with all programmed attributes while if keys are written to a text file only key codes names and order number in the list are recorded The UProg is supplied with two find commands namely the Find Key Duplicates A to find all the keys which have the same code but different descriptors and Find Key amp to find key de scriptors by the given code yN Besides UProg is supplied with the Defragment Key Memory tool the AS o intended for reordering
106. of the controller www bolid com 104 S2000 KDL Programming Programming Kevs If addressable zones of the controller are to be armed and disarmed locallv you should enroll in the S2000 KDL memorv codes of all the kevs user authenticators which will be used for this purpose as well as give all necessarv parameters of the kevs In case of centralized control kevs are registered in the database of the network controller and shall not be enrolled in the memorv of the S2000 KDL The S2000 KDL stores in its memory up to 512 user authenticator s codes If in an Orion system S2000 KDL controllers are connected to readers with different output interfaces Touch Memory Wiegand 26 Wiegand 44 etc designed to work with authenticators with the same type then the code of an authenticator presented on one reader can differ from the code of the same authenticator read by another reader in the system For example the code of a Proximity card read by a reader with output interface Wiegand 26 can differ from the code of the same card read by a reader with output interface Wiegand 44 or Touch Memory Or a PIN entered on a reader with output inter face Wiegand 6 or Wiegand 8 each entered digit of the code is sent to the controller individually will differ from the same code entered on a reader with output interface Wiegand 26 or Touch Memory all digits of the PIN are sent to the controller as a single block of data So if the S2000 KDL operates as a par
107. ogram a tvpe of the device connected to some address of the polling loop 1 Manuallv bv left clicking on the addressable zone followed bv selecting the device tvpe from the context menu see Figure 14 If the loop address of the addressable device has not vet been programmed assign the device to the address equal to the number of the addressable zone see Section Programming Loop Addresses of Addressable Devices 2 Automaticallv bv left double clicking on the zone or selecting Verifv Device Tvpe command from context menu of the addressable zone This command operates similar to the Poll and Write command but is executed only for the current addressable zone In case of auto detecting the tvpe of a device the device address should be pre programmed see Section Programming Loop Addresses of Addressable Devices t If the S2000 KDL while polling addressable devices cannot find some devices the most s probable cause is a configuration conflict resulted from programming some devices for a single loop address According to the type of a given device the UProg recognizes whether the device matches input or output of the polling loop The devices specified as an S2000 SP2 and LEM Ex SP are considered as addressable outputs their descriptors automatically appearing on the Outputs tab of the UProg The devices which are to be monitored and which conditions are to be analvzed that is all tvpes of detec tors and sensors and consumption controller
108. olarity connect the positive contacts of the polling loops to the contacts of the XT2 terminal block while the negative contacts to the contacts Improper polarity of wiring the polling loop will cause communication loss between the controller and addressable devices It is recommended to use twisted pair for the polling loop Polling Loop Topology Addressable devices can be connected to the polling loop relative to any network topology such as bus tree ring star and combined The total capacity of electrical wire must NOT exceed 0 1 UF In case of total capacity s exceeding the pointed value communications between the controller and ad dressable devices will be unstable which cause the controller to generate such messages as ERR IN RESPONSE COMM UNSTABLE or DISCONNECTED www bolid com 66 S2000 KDL Installation More reliable operation of the polling loop is ensured in case of its ring topologv Then in case of fail ing a segment of the polling loop addressable devices retain communication with the controller at one of the outputs PL1 or PL2 In addition to maintain communication between the controller and addressable devices in the event of a short circuit failure BRIZ short circuit isolators manufactured by Bolid should be brought to the poll ing loop Figure 5 Figure 6 and Figure 7 represent some topologies suitable for the polling loop BRIZ BRIZ 2000 KDL a detector BRIZ F
109. one of the assigned auxiliary zones is broken the relay is Switch On For A lime switched off for a time given by the Relay Activation Time for 26 Upon Auxiliary Zone this output PrGaking Otherwise the relav is on If an assigned input zone is disarmed the relay is switched 27 Switch On Upon Disarming on Otherwise the relay is off If an assigned input zone is disarmed the relay is switched 28 Switch Off Upon Disarming off Otherwise the relay is on If an assigned input zone is armed the relay is switched on SCR N KON Aming Otherwise the relay is off 30 Switch Off Upon Arming If an assigned input zone is armed the relay is switched off Otherwise the relay is on www bolid com 42 S2000 KDL Operation Principles Temmen en If an assigned addressable zone has entered Auxiliary Zone Alarm status the relay is switched on Otherwise the relay is off Switch On Upon Auxiliary Zone Breaking If an assigned addressable zone has entered Auxiliary Zone Alarm status the relay is switched off Otherwise the relay is on Switch Off Upon Auxiliary Zone Breaking If an assigned fire zone has entered Fire Alarm status and no assigned auxiliary zones are broken the relay is switched on for atime given by the Relay Activation Time for this out put Discharge 1 If two or more assigned fire zones have entered Fire Alarm status and no assigned auxiliary zones are broken the relay is switched on for a time given by
110. or example to program loop address of an S2000 AR1 disconnect ALARM and TAMPER device circuits from the input module and couple ALARM and TAMPER contacts for a time about 5 s For an S2000 AR2 input module disconnect its circuits device loops DL1 and DL2 and couple contacts DL1 and DL2 for a time about 5 s For an IPR513 3A simulate double actuating of the call point within 10 s by double turning the test key etc In all these cases each device having received the command over the polling loop reprograms its current address for the new address For addressable devices occupying several addresses within the polling loop the address specified in the command as a parameter will be assigned to a circuit with the number 1 for example DL1 for an S2000 AR2 The second circuit for example DL2 for an S2000 AR2 is automatically assigned to an incremented number For an S2000 AR8 the address specified in the command as a parameter max imum 120 will be assigned to the DL1 while addresses of other circuits device loops will be auto matically assigned sequentially in ascending order If programming the address of the addressable device has completed successfully or 10 minutes has elapsed since entering the programming mode then the controller exits programming mode To force S2000 KDL s exiting the mode of programming addressable devices right click on the relevant zone and select the Change Loop Address command from the context menu see Figure 1
111. or addressa ble devices Counting Threshold This threshold is programmed for zones of the Type 13 Counting which addressable utilitv meters S2000 ASR2 are monitored through The threshold implies the number of pulses counted and accumulated in the S2000 ASR2 memorv at which the value of counted pulses will be transmitted to the controller S2000 KDL This value should not be two small to avoid overloading the polling loop bv frequent communi cations However this value also should not be too much in order in case of S2000 ASR2 power failures the number of lost pulses can be ignored Bv default the counting threshold is equal to 1000 and can be changed in the range of 0 to 65535 To set change the counting threshold double click bv the left mouse button on the field of the parameter and tvpe a proper value or select the value bv arrow buttons Counter Integral Action Time This parameter is to be set for counting zones of the Type 13 which addressable controllers www bolid com 96 S2000 KDL Programming S2000 ASR2 work at It provides avoiding counting false pulses and means the time of inte gration upon filtering noise with a frequency higher than the frequency of counting pulses By default the Counter Integral Action Time is equal to 1 millisecond and can be changed for counters of different types in the range of 0 5 to 127 5 milliseconds The maximum value of the integral action time must half the length of a counted pulse
112. polling loop parame ters loop length branches see above shall be carried out for situations of opening the ring near PL1 and PL2 terminals of the controller If dropping the voltage between the S2000 KDL and the last addressable device in the loop exceeds an acceptable value in case of small cross section of wires communications between the controller and devices can be unstable In such case the controller will generate such messages as ERR IN RESPONSE COMM UNSTABLE or DISCONNECTED To analyze electric characteristics of the polling loop while commissioning you can use the command of requesting the voltage of the polling loop measured by addressable devices see Section Request ing Parameters of Addressable Devices of this Manual The returned value shows the amplitude of the loop supply voltage which is carried to the addressable devices The voltage value is considered to be normal if it is at least 8 V Requesting the voltage of the polling loop is supported only for those addressable devices which documentation contains information about supporting extended communi cation commands via the polling loop DPLS v2 xx CONNECTING ADDRESSABLE DEVICES Procedures of connecting addressable devices into the polling loop of the S2000 KDL are described in details in the documentation for the relevant devices To avoid confusion in the configuration the devices which addresses within the polling loop are set by DIP switches should be conn
113. r a time given by the Relay Activation Time for this output 12 Siren If an assigned zone has entered Intrusion Alarm status the relay is switched on for a time given by the Relay Activation Time for this output Otherwise the relay is off If an assigned zone has entered Fire Alarm status or Fire 13 Fire Output Prealarm status the relay is switched on Otherwise the relay is off If the is a zone being in the Trouble Disconnected Arming 14 Trouble Output Failed or Disarmed status the relay is switched off Otherwise the relay is on If an assigned input zone has entered such status as Intrusion Alarm Panic Alarm Fire Alarm Fire Prealarm Trouble Disconnected or Arming Failed the relay is 15 Fire Lamp switched on and off alternately If all assigned zones are armed and being in norm the relay is switched on Otherwise the relay is off If all assigned input zones are armed or disarmed the relay 16 Alarm Output 2 is switched on Otherwise the relay is off If an assigned input zone is being armed the relay is 17 Switch On For a Time switched on for a time given by the Relay Activation Time for Before Arming this output Otherwise the relay is off If an assigned input zone is being armed the relay is 18 Switch Off For a Time switched off for a time given by the Relay Activation Time for Before Arming this output Otherwise the relay is on 41 www bolid com SECURITY SYSTEMS Orion ISS e rom
114. r the network controller being in use The results of all operations requested bv user are displaved bv light and sound indication of the reader see Section Light and Sound Indication of the Readerof this Manual Compatibilitv of Readers Used in Orion Svstems If an Orion system uses a number of S2000 KDL controllers connected with readers with different tvpes of output interface Touch Memorv Wiegand 26 Wiegand 44 etc intended for reading elec tronic identifiers of the same tvpe then the code of an identifier read bv one reader can differ from the code of the same identified read bv another reader For example the code of a Proximitv card accepted bv a reader with Wiegand 26 interface can differ from the code of the same card accepted on a reader with Wiegand 44 or Touch Memorv interface Or a PIN code entered from a kevpad with Wiegand 6 or Wiegand 8 interface where each tvped character is sent to the controller individuallv will differ from the same code entered from a kevpad with Wiegand 26 or Touch Memorv interface where all digits of the PIN code are sent to the control ler in one parcel While developing and exploiting controllers within a large networked svstem please follow the recom mendations below 1 Registering codes of electronic kevs remotelv when the code is read bv a reader connected to an other controller the data format used by that reader shall match the data format of the reader con nected to the progra
115. r to identify the S2000 KDL within an Orion system a unique network address ranged from 1 to 127 must be assigned to it while programming From this address the controller will send the net work controller messages and receive centralized commands from it over the RS 485 The network address can be assigned to the S2000 KDL by means of network controller tools or using the UProg exe configuration tool see Section Network Settings of the S2000 KDL In systems with complicated network topology for example when Orion system data are to be trans ferred via local networks or fiber optic or radio relay channel there can be some communication delay occurring In such case to provide correct communications between the S2000 KDL and the network controller it can be necessary to increase the value of the Response Pause parameter of the control ler see Section Network Settings of the S2000 KDL Transferring Alarms and Status Messages to a Network Controller Being connected to a network controller either an S2000 S2000M control console or the Orion Pro software the S2000 KDL automatically transfers messages about its status and happened events including status changes of the polling loop and its inputs and outputs over the RS 485 interface www bolid com 56 S2000 KDL Operation Principles If a PC operates as the network controller it communicates data with the local RS 485 network through one of such interface converters as Pl GR S2000 PI
116. re the network address of the S2000 KDL as well as its configuration parameters event buffer and counted values received from addressable pulse meter controllers S2000 ASR2 if connected The multiplex addressable polling loop controller is intended for indoor installation and round the clock operation The S2000 KDL is not suitable for operation in corrosive and dusty environments as well as fire hazardous or explosive areas 9 www bolid com SEGURITV SVSTEMS Orion ISS www bolid com 10 S2000 KDL Specifications SPECIFICATIONS 11 www bolid com SECURITY SYSTEMS gt gt V VV V WV Y Controlled Addressable Devices Indicators LEDs Tamper Switch Event Lop Capacity RS 485 Communication Port Pre Operation Time Power Supply Input Voltage Input Current At 12 V At 24 V Input Power Polling Loop Connectable Devices Maximum Length www bolid com Orion ISS Up to 127 READY LED to indicate S2000 KDL power condition RS 485 LED to indicate communications over RS 485 LOOP LED to indicate loop condition Built in 255 events Yes 15 s max Two power inputs Bolid manufactured RIP 12 or RIP 24 battery backed pow er supplies are advisable 10 2 V 28 4 V dc 400 mA maximum value 80 mA with no connected devices 160 mA with 127 connected addressable devices with cur rent consumption of 0 5 mA each 200 mA maximum value 40 mA with no connected devices 80 mA wi
117. resholds defined for its relav outputs Device Indication Control This option defines the wav to control own indication of addressable devices equipped with LEDs and supporting the communication protocol DPLS v2 xx Left click on the box of this pa rameter of the programmed zone and select a proper value from the dropdown list 0 Indication Disabled as a rule indication of intrusion detectors are switched off so the at tacker could not estimate the detector range and the detection zone 1 by default Local Tactics controlling addressable device indication by its built in logic as described in the device manual 2 Controlled by the S2000 KDL as shown in Table 9 of this Manual Controlling device indication is provided only for those addressable devices which sup ports the communication protocol DPLS v2 xx see device manuals Save Mode e TI This option allows managing energv consumption of the addressable device depending on sta tus of its zone For detectors with microwave transmitter this parameter provides switching off the active element in reducing the impact of microwave radiation on people living in the pro tected area An addressable device is switched to the Save Mode when its zone has been dis armed the value of Disarmed Zone Monitoring being ignored Switching to the Save Mode is provided only for those addressable devices which sup port this mode and the communication protocol DPLS v2 xx see manuals f
118. responding to a condition of enter ing Fire Alarm status fixed temperature and rate of rise mode or The manual call point has been activated its glass has been bro ken or As shown in Table 2 for the S2000 AR1 SHORT FAILURE see Table 2 TROUBLE The S2000 IP fails to measure temperature Zone Type 4 Intrusion A zone of the Type 4 is to be used to monitor any intrusion detectors which are not supposed to send signals about tampering the detector or which doesn t support transmitting tamper alarms These zones are recommended to assign to a S2000 SMK addressable magnetic contacts or b S2000 SMK Estet addressable magnetic contacts for metal doors or c S2000 AR 2 addressable double input modules or d LEM Ex rev 2 loop expansion modules to connect conventional intrinsic safe intrusion detectors Available statuses of a zone of the Type 4 are the following ARMED The zone is fully monitored DISARMED The zone is in a norm the Disarmed Loop Monitoring parameter being set on there is no faults NOT READY TO ARM The zone has been broken being disarmed the Disarmed Loop Monitoring parameter being set on TROUBLE The addressable device has failed ARMING DELAY Arming the zone is delayed until the Arming Delay time has elapsed 25 www bolid com SEGURITV SVSTEMS Orion ISS ARMING FAILED The parameter monitored bv the addressable device is out of normal range at the time of arming the zone
119. ressable device connected to the zone otherwise the S2000 KDL will output zone configuration errors Table 13 displavs correspondence between tvpes of the addressable devices connected at a polling loop address and types of zones which can be programmed for the devices at the loop address To program the proper tvpe of zone double left click on the field of Zone Tvpe for the current zone and select the type in the dropdown list Table 13 Zone Types Suitable for Connected Addressable Devices Addressable Device Zone Type to Be Programmed S2000 IK S2000 ST S2000 STIK S2000 V 7 Entrance if you want to realize the mode of operating the intrusion S2000 SHIK detector with delaying alarms or S2000 SMK 11 Panic to receive attack messages without turning alarm equip S2000 PIK ment on or S2000 MW S2000 KT 4 Intrusion or 5 Intrusion With Tamper Check if vou want to take notice of tamper ing the intruder detector s enclosure or 6 Auxiliarv for auxiliarv zones from which oniv signal about break ing recovering are expected 3 Heat Fire if the detector operates in the threshold mode or 9 Heat Analogue With Programmable Thresholds in case of operat S2000 IP ing as an analogue fire detector or 10 Thermostatic if the detector is used for measuring ambient tem perature 1 Smoke Fire or DIP 34A 8 Smoke Analogue With Programmable Thresholds if the detector operates in the analog mode 91 www bolid com SECURITY
120. rion Pro software In such case presenting the authenticator to the reader of the S2000 KDL is considered as a request for remote centralized controlling partitions or individual devices of the Ori on system see Manual for the network controller being in use or for authorized access control only for systems operated by the Orion Pro software The reading device connected to the controller in addition to verifying users also performs light and sound indication of reacting the system to operations requested by users see Section Light and Sound Indication of the Reader of this Manual Configuration Parameters of Readers and User Authenticators Table 5 shows configuration parameters of the S2000 KDL which shall be adjusted accordingiv to the type of the reader connected to the controller as well as the parameters of user rights to control input zones of the S2000 KDL Table 5 Parameters of Readers and User Authenticators Keys Parameter Description Range Factory Value Defines the way to transfer the read Reader s Output code of the presented user key to the 1 Touch Memory Interface controller 2 Wiegand Forward LED Control Provides selecting the active logic level 1 active or Forward Polarity to turn the LED of the reader on Reverse 1 active 0 active www bolid com 48 S2000 KDL Operation Principles Factorv Number of Reader LEDs Forward Sounder Control Provides selecting the active logic leve
121. rk controller the S2000 KDL trans fers alarms and statuses of the polling loop and addressable zones over the RS 485 interface bus in order to display them remotely by means of the network controller S2000 K keypads S2000 BKI modules or to transmit them further to central monitoring stations via various communication channels PSTN cellular Ethernet Moreover the S2000 KDL can activate centralized control mechanisms upon receiving relevant commands from the network controller The event log of the S2000 KDL can store up to 255 last events For authorized control of the system an external ID reader with the output interface of Touch Memory or Wiegand can be connected to the special input of the S2000 KDL The reader can be used both for local controlling addressable zones of the S2000 KDL viewing zone statuses and arming disarming and for centralized remote control of various partitions of the Orion system if the S2000 KDL works under a network controller The S2000 KDL provides controlling light and sound indication of the reader to show system responses to user requests The user authenticators or electronic keys Dallas iButtons Proximity cards or digital PIN codes are to be preprogrammed that is enrolled into the S2000 KDL memory with the rights to arm and or dis arm specific addressable zones of the controller for local arming disarming or alternatively to the network controller database for centralized control Three
122. rmed Lit steadv in red Lit steadv Zones or partitions arsdisamau Lit steady in green Off Troubles in the zone Flashes with green partition once per second Flashes once per second Intrusion Alarm Fire alarm Fire Prealarm Arming Failed in the zone partition Flashes with red Flashes twice per second twice per second P Entering the mode of arm Flashes with green Flashes once per second ing disarming once per second p www bolid com 54 S2000 KDL Operation Principles Table 11 Reader Sound Indication The presented electronic kev authenticator is not found in the S2000 KDL memory the con troller is waiting for a decision of the network controller Access is closed prohibited or access denied A signal of duration 1 s Access is granted Two short beeps A beep Zones or partitions are armed Two short beeps Zones or partitions are disarmed Two short beeps Trouble in the zone partition Beeps once per second Intrusion Alarm in the zone partition Beeps five times per second Fire Alarm or Prealarm in the zone partition Long signals with short pauses once per second Arming the zone partition failed Beeps twice per second 55 www bolid com SEGURITV SVSTEMS Orion ISS COMMUNICATIONS BETWEEN THE S2000 KDL AND THE NETWORK CONTROLLER The S2000 KDL can operate both standalone and as a part of an Orion security system under the system network controller Being
123. s are considered as input addressable zones their de scriptors appearing automaticallv in the list of input zones on the Zones tab of the UProg The tvpe of the current addressable device can be copied for other zones using the Copv command at the right bottom part of the program window 87 www bolid com SEGURITV SVSTEMS Orion ISS Programming Loop Addresses of Addressable Devices The UProg allows programming changing loop addresses of addressable devices which store their addresses in their non volatile memories Programming loop addresses of addressable devices can also be performed by tools of the network controller see Section Programming Changing Device Loop Numbers bv Network Controller Tools of this Manual Vou are strongiv advised to program de vice addresses before mounting the devices in the protected premises To program the addressable device address which corresponds to an addressable zone of the controller right click on this zone and select the command Program Loop Address from the context menu see Figure 14 In state of sending this command the LOOP LED of the S2000 KDL shall flash doublv with long paus es If the addressable device is equipped with its own LED the device also shall indicate its program ming mode To notifv an addressable device that it is being assigned to a new address some procedures are to be performed with the device these procedures are described in details in the device s Manual F
124. s and dry chemical fire suppress ing systems to monitor conditions of fire protection equipment to block executing of tactics concern ing to fixed firefighting systems as well as to monitor conditions of equipment and alarms not directly connected with the security and fire alarm systems All addressable devices designed to work within the polling loop can be included into zones of the Type 6 except S2000 ASR2 utility meters and S2000 VT combined temperature and humidity sen sors Available statuses of a zone of Tvpe 46 are the following AUXILIARY ZONE RESTORED The zone is fullv monitored AUXILIARY ZONE ALARM Status of the detector or monitored circuit as shown in Table 2 differs from Norm 27 www bolid com SECURITV SVSTEMS Orion ISS The zone is switched from the Auxiliarv Zone Restored status to the Auxiliarv Zone Alarm status when the relevant detector or monitoring circuit of the input module responds with an alarm i for monitored circuits see Table 2 The zone is switched from the Auxiliarv Zone Alarm status to the Auxiliarv Zone Restored status if it has been in norm for the time equal to Recoverv Time see Section Zone s Configuration Parameters of this Manual Zone Tvpe 7 Entrance The Zone Type 7 Entrance Zone is similar to the Zone Type 5 except that breaking an armed zone of the Type 7 switches the zone firstly to the Entrance Alarm status If after elapsing some pre determined time no measures are taken to di
125. same actions excluding the impact of smoke or aerosol will lead to generating a FIRE TEST message which doesn t result in starting executive modules of the system Checking for operating and verifying ranges of intrusion detectors As a rule indication of intrusion detectors operating in quiescent mode is suppressed to prevent an attacker from finding out detector range If the detectors are to be checked for their operability and their responsibility to external conditions they can be temporary switched to the test mode To do this you should disarm the relevant zones and give the command Switch to the Detector Test Mode which results in the detectors indicating by their own built in algorithms as described in their manuals If the zone is broken the FIRE TEST message will be generated Test mode is applicable to all types of intrusion protection zones The Detector Test mode is turned on for a time specified by the user which gives the command The maximum time for testing detectors operability is 2 2 hours scum To perform test mode correctly equipment shall be activated for example the relevant jumper on the detector PCB shall be set on or the tamper switch shall be pressed by a special way see the Manual for the detector being in use To control indication of conventional detectors from third vendors we recommend to inter face them to the polling loop via addressable input modules S2000 AR1 rev 04 61 www bolid com
126. sarm the zone or to arm it then the zone is switched to the Intrusion Alarm status While the zone is being in the Entrance Alarm status no relav assigned to this zone with one of the general executive programs programs 1 to 8 or the Siren program program 12 is activated This allows a user entering the premises to reach the place where the alarm system control is located and to disarm the system without issuing alarms The time during which breaking an entrance zone is not considered to be an intrusion and no intrusion alarm is generated is defined by the Alarm Delay parameter in the controller configuration individually for each zone If this parameter set to zero for a zone then upon breaking the zone the Entrance Alarm status will be bypassed and the zone will be switched to the Intrusion Alarm status immediately The following addressable devices can be assigned to zones of the Type 7 a S2000 IK addressable passive infrared motion detectors or b S2000 SHIK addressable curtain PIR motion detectors or c S2000 SMK and S2000 SMK Estet addressable magnetic contacts or d S2000 AR1 S2000 AR2 and S2000 AR8 addressable input modules or e LEM Ex rev 2 intrinsically safe loop extension modules Available statuses of a zone of the Type 7 are the following ARMED The zone is fully monitored DISARMED The zone is in a norm the Disarmed Loop Monitoring parameter being set on the addressable device enclosure is closed the
127. t 34 Arming Disarming 35 Detector s Operating within the Polling Loop 37 Outputs of the Addressable Polling Loop 38 Configuration Parameters of Addressable Outputs 39 Local Executive Programs for Controlling Polling Loop Outputs 40 Controlling S2000 KDL Input Zones and User Authorization sss 48 Configuration Parameters of Readers and User Authenticators 48 Local Controlling Input Zones of the S2000 KDL 49 Centralized Control in the Orion System 50 Compatibility of Readers Used in Orion Systems 50 Light and So nd INA GMO C P 51 S2000 KDL Light Alarms 51 Light Indication of Addressable Devices 53 Light and Sound Indication of the Reader 54 Communications Between the S2000 KDL and the Network Controller 56 Transferring Alarms and Status Messages to a Network Controller 56 Remote Controlling the S2000 KDL over the RS 485 Interface 60 CI mew 63 Slandard EE c Q 64 Saf ty ae i cde CDM rc 64 52000 KDL Cj PC 64 Connecting the Polling LOOP e 66 Polling Loop Topology 66 3 www bolid com SECURITY SYSTEMS The Number of the Addressable Devices to Be Connected Length of the Polling Loop Connecting Addressable Devices sessi sisiisee esent nennt Wiring the HS 485 Interface Line a Connecting Power Supplies m Tm Connecting A Reader Mp
128. t addressable devices can be connected to the S2000 KDL among them in anv combination Y VVVWV VN Analogue addressable photoelectric smoke detectors DIP 34A Analogue addressable fixed temperature and rate of rise detectors S2000 IP Addressable manual call points IPR 513 3A Addressable input modules S2000 AR1 S2000 AR2 S2000 AR8 to provide connecting con ventional zone type detectors into the polling loop of the S2000 KDL Addressable intrusion detectors S2000 IK S2000 V S2000 ST S2000 STIK S2000 SHIK S2000 PIK S2000 MW S2000 SMK S2000 SMK Estet etc Addressable panic buttons S2000 KT Addressable loop extension modules LEM Ex rev 2 to provide connecting intrinsically safe dry contact detectors Addressable combined temperature and humidity sensors S2000 VT Addressable controllers S2000 ASR2 for two pulse output consumption meters Some addressable devices can occupy several addresses within the address space of the polling loop see manuals for the devices being in use Having polled the connected addressable devices the controller assigns all the addressable zones to some logic statuses depending on The status returned by the addressable device and the parameter value measured by the device such as optical density temperature etc or the resistance measured in the moni tored circuit of the input module for non addressable detectors and The monitoring tactics given for the addressable zone or
129. t of system with other similar controllers use the following guidelines G Ifthe keys are enrolled in the S2000 KDL memory remotely being read by the reader connected to another S2000 KDL the data format of remote reader MUST match the data format of the reader connected to the controller being programmed G The format of PIN codes entered from readers with interface Wiegand 6 or Wiegand 8 each entered digit of the code is sent to the controller individually matches the format of PIN codes entered from a PC keyboard for the UProg or Orion Database Administrator software So pro gramming the S2000 KDL which operates with such readers you can enter PIN codes in the UProg through the PC keyboard For PIN readers with another format of output codes of pro grammed key MUST be entered only on the keypad of the reader To program electronic keys authenticators select the Keys tab of the UProg see Figure 18 The left part of the window displays the list of keys which codes have been already stored in the S2000 KDL memory if enrolled Below the list you can see the number of already enrolled keys as well as a reminder that the maximum memory capacity to store keys is equal to 512 105 www bolid com SEGURITV SVSTEMS Orion ISS E UPROG Configuration Tool for S2000 KDL version 1 46 File Device Help J b gt CIT TH B OAGgGgAARRERAQ Key Attributes Key C
130. tch the data for mat of the reader Connected to the programmed S2000 KDL Ifa reader with interface Wiegand 6 or Wiegand 8 is connected to the S2000 KDL PIN codes can be entered either from the reader keypad or from the computer keyboard run under the UProg For PIN code readers with other data output for mats while programming the keys enter their cones only from the reader keypad Each key from the key list at Keys tab is assigned to a number of attributes see also Section Configu ration Parameters of Readers and User Authenticators of this Manual which can be specified or re vised see Figure 18 Key Name the textual field above the key toolbar Tape the textual name or comment which will be shown in the key list identifying the key Access Group Assign the key to an Access Group which contains addressable zones of the S2000 KDL enabled to be armed disarmed by a user presenting the key the Access Group has to be programmed before see Section Programming Access Groups above Disabled This switch provides easy key locking unlocking When the flag is set the key is disabled It can be necessary for example if the key is stolen or lost or should be temporary disused for any reason Delete the Key The term delete can have two meanings for keys in the UProg Configuration Tools A key can be physically deleted from the controller memory or can be marked as deleted when the key descriptor is excluded from the list
131. th 127 connected addressable devices with current consumption of 0 5 mA each 4 W max 127 addressable zones Addressable fire and intrusion detectors Addressable call points and panic buttons Addressable input modules to connect dry contact detec tors Addressable loop expansion modules Addressable temperature 8 humidity sensors Addressable executive modules Addressable consumption meters 700 m at wire cross section of 0 75 mm with wire diameter at least 0 9 mm S2000 KDL Specifications gt Y VV ON ON ON ON Y Y Loop Voltage Loop Current External ID Reader Output Interfaces Reader LEDs Sounder Distance ID Memory Capacity Operating Temperatures Relative Humidity Ingress Protection Rating Overall Dimensions Weight Average Lifetime Programming Connection to a PC 10V The total current consumption of all connected addressable devices must NOT exceed 100 mA One Reader Input to connect an external reader of Dallas iButtons Proximity cards or PIN codes Touch Memory 1 Wire u LAN Wiegand Controlling one or two reader LEDs by logical 5 V CMOS levels with current values being restricted by 10 mA at di rect connection Controlled by logical 5 V CMOS levels No more than 100 m from the S2000 KDL Up to 512 ID Codes 30 C to 50 C Up to 98 at 25 C IP20 157 mm x 107 mm x 36 mm about 0 3 kg 10 years By means of the UProg exe the tool for confi
132. the Relay Activation Time for this output Discharge A If an assigned fire zone has entered Fire Alarm status and no assigned auxiliary zones are broken the relay is switched on for a time given by the Relay Activation Time for this out put Discharge 1A If the value measured at one of the assigned zones has ex ceeded the value given by the relevant Temperature Hu Switch On If midity Increased Threshold the relay is switched on Measured Value Increased If the value measured at one of the assigned zones has dropped below the value given by the relevant Temperature Humidity Decreased Threshold the relay is switched off If the value measured at one of the assigned zones has dropped below the value given by the relevant Temperature Switch On If Humidity Decreased Threshold the relay is switched on Measured Value Decreased If the value measured at one of the assigned zones has ex ceeded the value given by the relevant Temperature Hu midity Increased Threshold the relay is switched off Executive Program 0 means that controlling the output in accordance with local cause amp effect links depending on statuses of local input zones of the S2000 KDL IS DISABLED The output can be managed remotely by network controlled commands received over the RS 485 interface The initial status of the output for the program 0 is Off Open Executive Programs 1 8 are to be used to control fire sirens light alarms and
133. the rights to manage the svs tem Local Access Groups programmed for the S2000 KDL define management rights for users which keys are registered by the controller to manage addressable zones of the S2000 KDL Each Access Group is assigned to a number of S2000 KDL addressable zones which will be armed and disarmed upon user s presenting a kev with attributes of the Access Group at the reader Up to 128 user Access Groups can be programmed for the controller The built in Access Group 0 provides users with the authorities to arm and disarm all addressable zones of the S2000 KDL this access group cannot be reprogrammed To program Access Groups of the S2000 KDL use the Access Groups tab of the UProg exe see Figure 17 UPROG Configuration Tool for S2000 KDL version 1 46 ee l N i File Device Lang Hi d B ms V AJ EM Addressable zone is disconnected MM Fire and Intruder Alarm Addressable Zone Bb Relay Addressable Zone Addressable Zones Figure 17 Programming Access Groups of the S2000 KDL In the top of the window there is a list of Access Groups which can be programmed for the S2000 KDL while in the bottom of the window there is a map of controller addressable zones Addressable zones of the S2000 KDL which can be armed or disarmed are highlighted in green Zones configured as addressable outputs are highlighted in blue while free zones are displayed in grey 103 www bolid com S
134. this program is open in case of a trouble of linked fire zones such as a short circuit failure open circuit failure or addressable device failure as well in case of lost communication between the S2000 KDL and monitored zones that is relevant ad dressable devices brought into the polling loop Also the output is open upon disarming and failing to arm the linked zones because fire protection zones have to be armed round the clock Executive Program 18 Switch Off For a Time Before Arming Executive Program 19 Switch Off For a Time Upon Arming The programs 18 and 19 allow automatic resetting of power of four wire smoke detec tors or fire detectors connected via specials relay bases to addressable interface modules upon detectors response Using the program 18 assign the linked zone zones to an Arming Delay see Section Zone s Configuration Parameters which is 2 s more than the Relay Activation Time programmed for the output 45 www bolid com SEGURITV SVSTEMS Orion ISS Executive Program 36 Switch On If Measured Value Increased Executive Program 37 Switch On If Measured Value Decreased Executive programs 36 Switch On If Measured Value Increased and 37 Switch On If Measured Value Decreased are to be used in automatic control systems to control vari ous physical quantities such as temperature or humidity To develop such a system each addressable output of the responsible for turning on off executive equipment is to be l
135. tors can have double destination They can be used to request access to protected premises and to arm disarm protected zones If the S2000 KDL operates in such a system requested operation is selected by means of an additional button connected to the S2000 KDL see Figure 11 When the button is pressed down the DO and GND contacts are coupled then presenting an elec tronic key to the S2000 KDL reader will cause S2000 KDL s requesting the network controller for giv ing a command key to arm disarm relevant system zones Otherwise presenting the key will be con sidered as the request to access protected premises S2000 KDL Figure 11 Wiring the Arming Request Button GETTING STARTED After installing the controller inspect all the installation for proper mounting and turn the S2000 KDL power on If the controller is operable its READY LED will be lit steady in green 73 www bolid com SEGURITV SVSTEMS Orion ISS www bolid com 74 S2000 KDL Programming PROGRAMMING oo 75 www bolid com SEGURITV SVSTEMS Orion ISS For using the S2000 KDL in a specific situation the controller and its polling loop should be configured to cooperate with connected addressable devices in accordance with the tasks expected to be solved and the specific application fire or intruder alarms building management etc To program the S2000 KDL do the following gt Assign the controller to a network address within the RS 485 inter
136. trusion Alarm Intrusion Alarm Intrusion Alarm Intrusion Alarm Intrusion Alarm Intrusion Alarm Intrusion Alarm Trouble Trouble Trouble Entrance Alarm Entrance Alarm Entrance Alarm Intrusion Alarm NOTES Panic Alarm Panic Alarm Panic Alarm Panic Alarm The status Alarm is available only for S2000 AR2 and S2000 AR8 modules All statuses of monitored circuits shown in the table concern zones being in the Armed status expect for zones of the Type 6 Zone Tvpe 3 Heat Fire The following devices can be assigned to a zone of the Type 3 a analogue addressable fixed temperature and rate of rise detectors S2000 IP S2000 IP rev 01 and S2000 IP rev 02 operated in addressable threshold mode or b S2000 AR1 addressable single input modules to connect dry contact fire heat detectors into the polling loop or c IPR 513 3A addressable manual call points www bolid com 24 S2000 KDL Operation Principles Available statuses of a zone of the Type 3 are the following ARMED The zone is fully monitored DISARMED The zone is in norm if there is no faults ARMING DELAY Arming the zone is delayed until the Arming Delay time has elapsed ARMING FAILED The parameter monitored by the addressable device is out of normal range at the time of arming the zone PREALARM The heat detector has registered temperature s change or exceed ing the predetermined value cor
137. ty values for this zone www bolid com 34 S2000 KDL Operation Principles DO NOT contuse the humiditv increased decreased thresholds defined for the Humiditv e Measurement zone and the same thresholds defined for addressable outputs of the S2000 KDL Humiditv value s being out of the range programmed for a Humiditv Measurement zone causes the S2000 KDL to switch the zone to the Level High Level Low status and to transmit the relevant message to the network controller If on the contrarv measured humiditv values are out of the range programmed for an output assigned with this zone in the S2000 KDL configuration the controller activates the output as defined bv its predetermined executive program The controller also trans mits the changed output status to the network controller if the relevant switch in the out put s settings allows that see Section Configuration Parameters of Addressable Out puts Arming Disarming The S2000 KDL supports arming and disarming for all input addressable zones except zones 13 Counting In case of local control Arm Disarm commands are generated by the controller after user s present ing the proper authenticator electronic key on the reader connected to the S2000 KDL see Section Local Controlling Input Zones of the S2000 KDL of this Manual Otherwise in case of centralized control Arm Disarm commands are received from the network controller over the RS 485 interface The S2000 KD
138. up to 127 addressable zones Each addressable zone of the S2000 KDL can be config ured either as an input or as an output An input zone is the one through which the controller monitors the connected initiating devices and analyses received data generating relevant sta tuses and activating executive modules if programmed An output zone is the one to which the controller sends executive commands for the connected executive module if programmed Arming Disarming Starting cancellation generating alarms for an input addressable zone Network Address A unique number of the controller 1 to 127 within the local RS 485 network of the Orion integrated security system S2000 KDL Table of Contents G ATA a 5 Specifications ia kiri sewacarniteadswaaawnd aiaa aaaeaii daaa iaaa aiaiai 11 Operation PHBDEIBISS A nnn nnnnnnnnnnn ot i aA 15 Multiplex Addressable Polling Loop of the S2000 KDL sss 16 IOUT zones of th Polling LOOD aou eid eie orato dee He 18 Zone s Configuration Parameters 19 Zone Type 1 Smoke Fire 23 Zone Type 2 Combined Fire 23 Zone Type 3 Heat Fire 24 Zone Type 4 Intrusion 25 Zone Type 5 Intrusion with Tamper Monitoring 26 Zone Type 6 Auxiliary 27 Zone Type 7 Entrance 28 Zone Type 8 Smoke Analogue With Programmable Thresholds 29 Zone Type 9 Heat Analogue With Programmable Thresholds 30 Zone Type 10 Thermostatic 31 Zone Type 11 Panic 32 Zone Type 13 Counting 33 Zone Type 15 Humidity Measuremen
139. uration Inspect attaching addressable devices to the polling loop and repair their communications with the controller Or gt One or more addressable zones are in Error in Response or Unstable Communication status that can result from high distances between the addressable devices and the control ler or other design errors of the polling loop see Section Connecting the Polling Loop of this Manual 112 S2000 KDL 7 LOOP LED flashes with vellow twice per second 7 LOOP LED flashes with vellow Maintenance Short circuit failure or another trouble of the polling loop Repair the trouble Communication is lost with at least one addressable device via once per second or flashes in vel 1 and or2 polling loop terminals Repair the trouble low being lit steadv in green Troubles of the S2000 KDL Transferred to the Orion Svstem The following messages about troubles of the polling loop or addressable zones of the S2000 KDL can be displaved bv the network controller or svstem kevpads S2000 K these messages being dis plaved with specified addresses or names of the controller and the addressable zones 7 ERR IN RESPONSE COMM UNSTABLE DISCONNECTED RELAV DISCONNECT ZONE CONFIG ERR These messages can be generated at state of poor communica tions between the controller and the addressable device The rea sons for poor communications can be as follows gt The voltage drop to the last addressable device in c
140. used in a small fire amp intruder alarm system the S2000 KDL can operate standalone controlling polling loop outputs automatically in accordance with the pre programmed logic depending on status es of the input addressable zones which are assigned to these outputs However the S2000 KDL maximizes its operability while working as part of an Orion security system under a network controller which can be an S2000 S2000M fire and alarm console or a PC with Orion Pro software installed Operating under the network controller the S2000 KDL transmits over the RS 485 interface bus en tire information about monitored events such as current statuses of addressable devices arm ing disarming attempts troubles of addressable devices relay outputs the polling loop the device itself etc Allthese data can be output to be observed by a system operator or a security administra tor or written into a log for further analysis or reporting or to be output to external indicator modules or to be used within complicated automatic system management scenarios This information can also be transmitted out of the system to a fire brigade or a central monitoring station over a phone line a GSM channel or Internet When the S2000 KDL operates as a part of an Orion system it allows controlling its outputs centrally arming disarming its zones centrally resetting its alarms remotely as well as requesting current zone parameters remotely see below In orde
141. ver the RS 485 interface For zones of the Type 8 in case when the value returned by the detector exceeds the Prealarm Sensitivitv Threshold programmed for the current time of the day for Day mode or Night mode the S2000 KDL sends the network controller a Fire Prealarm message specifying the zone loop address and then switches the zone to the Fire Prealarm status If the value returned by the detector exceeds the Fire Sensitivity Threshold for the current time of the day then the controller sends a Fire Alarm message specifying the loop address of the zone and switching the zone to the Fire Alarm status For zones of the Type 9 the method of processing responses from addressable devices is similar to those mentioned above for zones of the Type 8 except that the values of sensitivity thresholds does not depend on time of the day A Service Required message with specifying the zone address is generated for zones of the Types 1 and 8 in such case if the contamination value returned by the addressable detectors exceeds the own threshold value of the detector for zones of the Types 1 and 8 or the Contamination Thresh old value programmed for the zone for at least two hours for zones of the Type 8 Having received such message please clean the smoke chamber of the detector In case of a failure of the detector s sensor or its measuring channel a Trouble message is sent to the network controller over the RS 485 interface 37 www bolid
142. vice aoe Help a4 C b DIP34A 01 02 v 1 20 DIP34A 01 02 v 1 20 DIP34A 01 02 v 1 20 Not Connected Not Connected 52000 AR8 S2000 AR8 2000 AR8 2000 AR8 2000 AR8 52000 AR8 52000 AR8 Not Connected Not Connected Not Connected lt gt Request the Device Type 9 Programmed and real types match The programmed device is not found Fu i Programmed and real types mismatch An unknown device is found kud Enter numbers of zones which current parameters are to be applied to For Dow example 1 2 13 18 Copy only the current setting Copy input to output matching Device Type Outputs AValves AAccess Groups Keys Figure 12 UProg Window for Configuring the S2000 KDL 79 www bolid com SECURITV SVSTEMS Orion ISS If a configuration reading error message has been received you can try to read configuration once more disabling the Read By Blocks option from the Device menu command You can also get an access to the controller settings by loading the controller configuration from the relevant file with cnu extension written to any data storage using the File Load Configuration File command or the lt F3 gt button or the EA toolbar icon Besides a new configuration file can be created by using the File gt New Configuration menu com mand or the lt Ctrl N gt button or the al badia icon The command File Base Configuration is intended for loading factory setting values to the empty configuration
143. wer Input Monitoring parameter on off left click the relevant box at the right The Both Power Inputs Monitoring parameter is automatically turns on while turning on the EN 54 Indication parameter see below www bolid com 82 S2000 KDL Programming EN 54 Indication The parameter allows displaving statuses of fire detection zones by the controller LEDs in ac cordance with requirements of European Standards EN54 2 see Section S2000 KDL Light Alarms of this Manual If the parameter is set on indication is performed in accordance with requirements of Europe an Standards EN54 2 If otherwise the parameter is set off indication is performed in accord ance with the own logic of the S2000 KDL By default the parameter is set off To turn it on tick the relevant box at the right from the parameter bv left mouse button Upon turning on the EN 54 Indication parameter the Both Power Inputs Monitoring op s tion is set on automatically see above Ring Topology This parameter allows regulating output of messages about polling loop failures in case of poll ing loop s having ring topology If the parameter is set on messages about polling loop s fail ures are output for each output of DPLS1 and DPLS2 individually For example in case when the polling loop has been open the controller will generate messages 2WIRE1 LOST and or 2WIRE2 LOST allowing locating the point of breaking quickly By default the parameter is off
144. will describe parameters common for a number of input addressable zones of the polling loop 21 www bolid com SECURITV SVSTEMS Orion ISS The parameter Auto Rearming is to be set if the zone being in the Disarmed status see Section Arming Disarming below is supposed to be armed automaticallv when it is recovered after breaking The parameter Auto Arming After Alarms provides automatic switching from the statuses Intrusion Alarm Fire Alarm and Fire Prealarm to the Armed status upon recovering the zone after its breaking In such a case to be armed the zone must be in norm during the time more or equal to Recoverv Time If the parameter Disarmed Loop Monitoring is set on for a zone of the Type 4 5 7 or 11 then the status changes of the zone will be monitored even though it is disarmed When the zone has been broken recovered the controller generates messages Not Readv To Arm and Readv To Arm respec tivelv The zone to be considered as recovered it must be in norm for a time equal to Recoverv Time If a zone must be monitored be armed round the clock use the parameter Never Disarmed This parameter is set on for fire protection and panic zones 1 3 and 11 to avoid their accidental dis arming When a Disarm command has been received for a zone which Never Disarmed parameter is set on the zone either enters the armed status if it was in norm previously or otherwise the controller generates a message about the current status o
145. y the screw head can be sealed www bolid com 64 S2000 KDL Installation Tamper Switch XP2 Jumper XT1 Block E GMES Sas N LL XT2 Block Figure 2 S2000 KDL Base and PCB 124 OT A Guide elements for DIN rail mounting N co l 2holes 23 Snap on clip for DIN rail mounting Figure 3 Overall and Mounting Dimensions of the S2000 KDL 65 www bolid com SEGURITV SVSTEMS Orion ISS Figure 4 schematically shows the printed circuit board of the S2000 KDL with terminal block XT1 and XT2 to connect external circuits which will be described in further sections of this document s2000 IK S2000 AR2 BRIZ S2000 ST S2000 V DIP 34A S2000 KDL XT2 XTI nun ID Reader D1 ano 8 po 7 IPR513 3A S2000 SMK The Polling Loop ET Network Controller PL2 ig S2000 AR8 S2000 SMK S20004P BRIZ EHE ower Supply l 1 Power Supply Figure 4 S2000 KDL Wiring Diagram CONNECTING THE POLLING LOOP Connect the polling loop to the relevant contacts of the XT2 terminal block see Figure 4 according to the proper p
146. y for those ad dressable devices which store these addresses in their non volatile memory You are strongly advised to program loop addresses before mounting the devices in protected premises Programming loop addresses of addressable devices is performed if several addressable devices within the polling loop have the same loop address or it the current address is not known To program a loop address send the S2000 KDL a command to turn programming mode on from the S2000 S2000M console LOOP LED of the S2000 KDL shall flash doubly with long pauses To notifv an addressable device that it is being assigned to a new address some procedures are to be performed with the device these procedures are described in details in the device s Manual For example to program loop address of an S2000 AR1 disconnect ALARM and TAMPER device circuits from the input module and couple ALARM and TAMPER contacts for a time about 5 s For an S2000 AR2 input module disconnect its circuits device loops DL1 and DL2 and couple DL1 and DL2 contacts for a time about 5 s For an IPR513 3A simulate double actuating of the call point within 10 s by double turning the test key etc In all these cases each device having received the command over the polling loop reprograms its current address for the new address For addressable devices occupying several addresses within the polling loop the address specified in the command as a parameter will be assigned to a circuit wit